PEA-LINE-MIRRORING-IPDSLAM
File:
PEA-LINE-MIRRORING-IPDSLAM.mib (6986 bytes)
Imported modules
Imported symbols
Defined Types
LineMirroringEntry |
|
SEQUENCE |
|
|
|
|
upstreamLineMirrorVlanId |
Unsigned32 |
|
|
upstreamLineMirrorVlanPriority |
Unsigned32 |
|
|
downstreamLineMirrorVlanId |
Unsigned32 |
|
|
downstreamLineMirrorVlanPriority |
Unsigned32 |
|
Defined Values
peaLineMirroringIpDslam |
1.3.6.1.4.1.193.72.300.90 |
This MIB is used to configure end-user line mirroring in the IP DSLAM.
When upstream and downstream traffic mirroring is enabled, all traffic from
an end-user line is replicated, tagged with an operator specified VLAN
tag and sent on the IP DSLAM's uplink interface, as illustrated below.
IP DSLAM
_____________________________________
| |
| Service VLAN |
| -------------------------->-------->|----------> End-user
uplink |/ ) |
<-------->| / |
|\ Downstream Mirror VLAN / |
| \<------------------------ |
|_____________________________________|
IP DSLAM
_____________________________________
| |
| Service VLAN |
| <-----------------------------<-----|<---------- End-user
uplink |/ / |
<-------->| / |
|\ Upstream Mirror VLAN / |
| \<------------------------ |
|_____________________________________|
Different VLANs can be used for upstream and downstream traffic mirroring,
but the same VLAN may be used for both traffic directions. It is also
possible to only mirror traffic in one direction, or to start mirroring on
more than one line.
The traffic mirroring function will not interfere with the normal services
as long as the VLAN used for traffic mirroring is not used for services.
If a mirror VLAN collides with a service VLAN, the behavior is undefined.
|
MODULE-IDENTITY |
|
|
|
lineMirroringTable |
1.3.6.1.4.1.193.72.300.90.5 |
The lineMirroringTable is used to configure traffic mirroring for the
end-user lines in the IP DSLAM.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
LineMirroringEntry |
|
lineMirroringEntry |
1.3.6.1.4.1.193.72.300.90.5.5 |
lineMirroringEntry is an entry in the lineMirroringTable.
A lineMirroringEntry is used to configure line mirroring for one line
in the IP DSLAM. The line to configure is identified by lineIndex.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LineMirroringEntry |
|
|
upstreamLineMirrorVlanId |
1.3.6.1.4.1.193.72.300.90.5.5.5 |
The parameter upstreamLineMirrorVlanId is used to enable/disable mirroring
of all upstream traffic on the specific line.
When mirroring is enabled, upstream traffic from all PVC's in the line is
replicated (before service VLAN tag is added) and tagged with the VLAN
specified with upstreamLineMirrorVlanId. The traffic is then forwarded on
the uplink interface of the IP DSLAM.
To enable upstream traffic mirroring for a line, set upstreamLineMirrorVlanId
to a value in the range 0x0000..0x0FFF, to disable upstream traffic mirroring
set upstreamLineMirrorVlanId to 0xFFFF.
The value configured with upstreamLineMirrorVlanId will survive a restart of
the IP DSLAM.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0000..0FFF | FFFF |
|
upstreamLineMirrorVlanPriority |
1.3.6.1.4.1.193.72.300.90.5.5.10 |
The parameter upstreamLineMirrorVlanPriority is used in conjunction with
upstreamLineMirrorVlanId when upstream traffic mirroring is enabled.
upstreamLineMirrorVlanPriority specifies the VLAN priority used when
sending the mirrored traffic on the IP DSLAM uplink interface.
The value configured with upstreamLineMirrorVlanPriority will survive a
restart of the IP DSLAM.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..7 |
|
downstreamLineMirrorVlanId |
1.3.6.1.4.1.193.72.300.90.5.5.15 |
The parameter downstreamLineMirrorVlanId is used to enable/disable mirroring
of all downstream traffic on the specific line.
When mirroring is enabled, downstream traffic to all PVC's in the line is
replicated (after service VLAN tag is removed) and tagged with the VLAN
specified with downstreamLineMirrorVlanId. The traffic is then forwarded on
the uplink interface of the IP DSLAM.
To enable downstream traffic mirroring for a line, set downstreamLineMirrorVlanId
to a value in the range 0x0000..0x0FFF, to disable upstream traffic mirroring,
set downstreamLineMirrorVlanId to 0xFFFF.
The value configured with downstreamLineMirrorVlanId will survive a restart of
the IP DSLAM.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0000..0FFF | FFFF |
|
downstreamLineMirrorVlanPriority |
1.3.6.1.4.1.193.72.300.90.5.5.20 |
The parameter downstreamLineMirrorVlanPriority is used in conjunction with
downstreamLineMirrorVlanId when upstream traffic mirroring is enabled.
downstreamLineMirrorVlanPriority specifies the VLAN priority used when
sending the mirrored traffic on the IP DSLAM uplink interface.
The value configured with downstreamLineMirrorVlanPriority will survive a
restart of the IP DSLAM.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..7 |
|