PDUSNMP

File: PDUSNMP.mib (149405 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212
RFC-1215 SNMPv2-SMI SNMPv2-CONF
SNMPv2-TC

Imported symbols

enterprises IpAddress Gauge
TimeTicks DisplayString OBJECT-TYPE
TRAP-TYPE NOTIFICATION-TYPE MODULE-IDENTITY
Integer32 Unsigned32 OBJECT-GROUP
NOTIFICATION-GROUP MODULE-COMPLIANCE DateAndTime
TEXTUAL-CONVENTION

Defined Types

TrapDestinationsEntry  
SEQUENCE    
  trapDestinationsIndex INTEGER
  trapDestinationsStatus INTEGER
  trapDestinationsIP IpAddress
  trapDestinationsCommunity DisplayString

Pdu-socketsEntry  
SEQUENCE    
  socket-Index INTEGER
  socket-Number INTEGER
  socket-Equipment DisplayString
  socket-ONOFF INTEGER
  socket-AMPS INTEGER
  socket-KWH Integer32
  socket-INFO INTEGER

Pdu-SecurityEntry  
SEQUENCE    
  pdu-Security-Index INTEGER
  pdu-Security-Code Integer32

Socket-ThresholdsEntry  
SEQUENCE    
  socket-ThresholdsNumber INTEGER
  socket-AMPSLowAlarm INTEGER
  socket-AMPSLow INTEGER
  socket-AMPSHighAlarm INTEGER
  socket-AMPSHigh INTEGER

Slave-socketsEntry  
SEQUENCE    
  slave-socket-Index INTEGER
  slave-socket-Number INTEGER
  slave-socket-NotUsed1 DisplayString
  slave-socket-ONOFF INTEGER
  slave-socket-AMPS INTEGER
  slave-socket-KWH Integer32

Slave-Global-Entry  
SEQUENCE    
  slave-Global-Index INTEGER
  slave-Global-Status INTEGER
  slave-Global-Address INTEGER
  slave-Global-Nosockets INTEGER
  slave-Global-meter1-VRMS INTEGER
  slave-Global-meter1-IRMS INTEGER
  slave-Global-meter1-VRMS INTEGER
  slave-Global-meter1-KWH Integer32
  slave-Global-meter1-KW INTEGER
  slave-Global-meter1-TPMU INTEGER
  slave-Global-meter1-PF INTEGER
  slave-Global-environmental-Temp1 INTEGER
  slave-Global-environmental-Temp2 INTEGER
  slave-Global-environmental-Temp3 INTEGER
  slave-Global-environmental-Temp4 INTEGER
  slave-Global-environmental-Temp5 INTEGER
  slave-Global-environmental-Temp6 INTEGER
  slave-Global-environmental-Temp7 INTEGER
  slave-Global-environmental-Temp8 INTEGER
  slave-Global-environmental-HumidityTemp INTEGER
  slave-Global-environmental-Humidity INTEGER
  slave-Global-environmental-Contact1 INTEGER
  slave-Global-environmental-Contact2 INTEGER
  slave-Global-environmental-Contact3 INTEGER
  slave-Global-Security-Door INTEGER
  slave-Global-Security-Lock INTEGER
  slave-Global-sockets Integer32
  slave-Global-socket1Amps INTEGER
  slave-Global-socket2Amps INTEGER
  slave-Global-socket3Amps INTEGER
  slave-Global-socket4Amps INTEGER
  slave-Global-socket5Amps INTEGER
  slave-Global-socket6Amps INTEGER
  slave-Global-socket7Amps INTEGER
  slave-Global-socket8Amps INTEGER
  slave-Global-socket9Amps INTEGER
  slave-Global-socket10Amps INTEGER
  slave-Global-socket11Amps INTEGER
  slave-Global-socket12Amps INTEGER
  slave-Global-socket13Amps INTEGER
  slave-Global-socket14Amps INTEGER
  slave-Global-socket15Amps INTEGER
  slave-Global-socket16Amps INTEGER
  slave-Global-socket17Amps INTEGER
  slave-Global-socket18Amps INTEGER
  slave-Global-socket19Amps INTEGER
  slave-Global-socket20Amps INTEGER
  slave-Global-socket21Amps INTEGER
  slave-Global-socket22Amps INTEGER
  slave-Global-socket23Amps INTEGER
  slave-Global-socket24Amps INTEGER
  slave-Global-socket25Amps INTEGER
  slave-Global-socket26Amps INTEGER
  slave-Global-socket27Amps INTEGER
  slave-Global-socket28Amps INTEGER
  slave-Global-socket29Amps INTEGER
  slave-Global-socket30Amps INTEGER
  slave-Global-socket31Amps INTEGER
  slave-Global-socket32Amps INTEGER
  slave-Global-socket1kWh Integer32
  slave-Global-socket2kWh Integer32
  slave-Global-socket3kWh Integer32
  slave-Global-socket4kWh Integer32
  slave-Global-socket5kWh Integer32
  slave-Global-socket6kWh Integer32
  slave-Global-socket7kWh Integer32
  slave-Global-socket8kWh Integer32
  slave-Global-socket9kWh Integer32
  slave-Global-socket10kWh Integer32
  slave-Global-socket11kWh Integer32
  slave-Global-socket12kWh Integer32
  slave-Global-socket13kWh Integer32
  slave-Global-socket14kWh Integer32
  slave-Global-socket15kWh Integer32
  slave-Global-socket16kWh Integer32
  slave-Global-socket17kWh Integer32
  slave-Global-socket18kWh Integer32
  slave-Global-socket19kWh Integer32
  slave-Global-socket20kWh Integer32
  slave-Global-socket21kWh Integer32
  slave-Global-socket22kWh Integer32
  slave-Global-socket23kWh Integer32
  slave-Global-socket24kWh Integer32
  slave-Global-socket25kWh Integer32
  slave-Global-socket26kWh Integer32
  slave-Global-socket27kWh Integer32
  slave-Global-socket28kWh Integer32
  slave-Global-socket29kWh Integer32
  slave-Global-socket30kWh Integer32
  slave-Global-socket31kWh Integer32
  slave-Global-socket32kWh Integer32
  slave-Global-socket33Amps INTEGER
  slave-Global-socket34Amps INTEGER
  slave-Global-socket35Amps INTEGER
  slave-Global-socket36Amps INTEGER
  slave-Global-socket37Amps INTEGER
  slave-Global-socket38Amps INTEGER
  slave-Global-socket39Amps INTEGER
  slave-Global-socket40Amps INTEGER
  slave-Global-socket41Amps INTEGER
  slave-Global-socket42Amps INTEGER
  slave-Global-socket43Amps INTEGER
  slave-Global-socket44Amps INTEGER
  slave-Global-socket45Amps INTEGER
  slave-Global-socket46Amps INTEGER
  slave-Global-socket47Amps INTEGER
  slave-Global-socket48Amps INTEGER
  slave-Global-socket33kWh Integer32
  slave-Global-socket34kWh Integer32
  slave-Global-socket35kWh Integer32
  slave-Global-socket36kWh Integer32
  slave-Global-socket37kWh Integer32
  slave-Global-socket38kWh Integer32
  slave-Global-socket39kWh Integer32
  slave-Global-socket40kWh Integer32
  slave-Global-socket41kWh Integer32
  slave-Global-socket42kWh Integer32
  slave-Global-socket43kWh Integer32
  slave-Global-socket44kWh Integer32
  slave-Global-socket45kWh Integer32
  slave-Global-socket46kWh Integer32
  slave-Global-socket47kWh Integer32
  slave-Global-socket48kWh Integer32
  slave-Global-sockets2 Integer32
  slave-Global-meter1-Freq INTEGER
  slave-Global-meter2-VRMS INTEGER
  slave-Global-meter2-IRMS INTEGER
  slave-Global-meter2-VRMS INTEGER
  slave-Global-meter2-KWH Integer32
  slave-Global-meter2-KW INTEGER
  slave-Global-meter2-TPMU INTEGER
  slave-Global-meter2-PF INTEGER
  slave-Global-meter2-Freq INTEGER
  slave-Global-meter3-VRMS INTEGER
  slave-Global-meter3-IRMS INTEGER
  slave-Global-meter3-VRMS INTEGER
  slave-Global-meter3-KWH Integer32
  slave-Global-meter3-KW INTEGER
  slave-Global-meter3-TPMU INTEGER
  slave-Global-meter3-PF INTEGER
  slave-Global-meter3-Freq INTEGER

Defined Values

pdu-SNMP 1.3.6.1.4.1.38218.1
IPT SNMP PDU MIB definition
MODULE-IDENTITY    

ipt-pdu-SNMP 1.3.6.1.4.1.38218
OBJECT IDENTIFIER    

slave-SiteTotals 1.3.6.1.4.1.38218.1.1
OBJECT IDENTIFIER    

slave-Server 1.3.6.1.4.1.38218.1.2
OBJECT IDENTIFIER    

pdu-Configuration 1.3.6.1.4.1.38218.1.3
OBJECT IDENTIFIER    

trap-Destinations 1.3.6.1.4.1.38218.1.4
OBJECT IDENTIFIER    

pdu-Information 1.3.6.1.4.1.38218.1.5
OBJECT IDENTIFIER    

pdu-Meters 1.3.6.1.4.1.38218.1.6
OBJECT IDENTIFIER    

pdu-sockets 1.3.6.1.4.1.38218.1.7
OBJECT IDENTIFIER    

pdu-Environmental 1.3.6.1.4.1.38218.1.8
OBJECT IDENTIFIER    

pdu-Security 1.3.6.1.4.1.38218.1.9
OBJECT IDENTIFIER    

pdu-Logs 1.3.6.1.4.1.38218.1.10
OBJECT IDENTIFIER    

pdu-Traps 1.3.6.1.4.1.38218.1.11
OBJECT IDENTIFIER    

pdu-TrapThresholds 1.3.6.1.4.1.38218.1.11.1
OBJECT IDENTIFIER    

slave-pdus 1.3.6.1.4.1.38218.2
OBJECT IDENTIFIER    

slave-Information 1.3.6.1.4.1.38218.2.2
OBJECT IDENTIFIER    

slave-Status 1.3.6.1.4.1.38218.2.3
OBJECT IDENTIFIER    

slave-sockets 1.3.6.1.4.1.38218.2.4
OBJECT IDENTIFIER    

slave-Environmental 1.3.6.1.4.1.38218.2.5
OBJECT IDENTIFIER    

slave-Security 1.3.6.1.4.1.38218.2.6
OBJECT IDENTIFIER    

slave-Traps 1.3.6.1.4.1.38218.2.7
OBJECT IDENTIFIER    

slave-TrapSetNotifications 1.3.6.1.4.1.38218.2.7.1
OBJECT IDENTIFIER    

slave-TrapClearNotifications 1.3.6.1.4.1.38218.2.7.2
OBJECT IDENTIFIER    

slave-Global 1.3.6.1.4.1.38218.3
OBJECT IDENTIFIER    

slave-SiteTotalkWh 1.3.6.1.4.1.38218.1.1.1
Total Energy used by all slaves on site in kWh x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-SiteTotalBtu 1.3.6.1.4.1.38218.1.1.2
Total Energy used by all slaves on site in Btu x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-SiteTotalKgCO2 1.3.6.1.4.1.38218.1.1.3
Total Energy used by all slaves on site in KgCO2 x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Nopdus 1.3.6.1.4.1.38218.1.2.1
Compatible - Number of pdu's connected in SLAVE mode
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..32  

slaves-Online 1.3.6.1.4.1.38218.1.2.2
Compatible - Number of pdu's ONLINE in SLAVE mode.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..32  

slave-ServerStatus 1.3.6.1.4.1.38218.1.2.3
Compatible - Server status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER stopped(0), running(1), searching(2), getinfo(3), listening(4)  

pdu-ClientName 1.3.6.1.4.1.38218.1.3.1
Compatible - pdu Client name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

pdu-LocationName 1.3.6.1.4.1.38218.1.3.2
Compatible - pdu Location Name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

pdu-FirmwareVersion 1.3.6.1.4.1.38218.1.3.3
Compatible - pdu firmware version.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

pdu-KgCO2Conversion 1.3.6.1.4.1.38218.1.3.4
Compatible - KgCO2 conversion factor x1000 [544 = 0.544]
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..1000  

pdu-MODBUSTimeout 1.3.6.1.4.1.38218.1.3.5
Compatible - MODBUS Timeout in mS.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 500..5000  

pdu-MODBUSRetry 1.3.6.1.4.1.38218.1.3.6
Compatible - MODBUS Retry value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

pdu-NotUsed1 1.3.6.1.4.1.38218.1.3.7
Compatible - Not used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0  

pdu-AlarmPeriod 1.3.6.1.4.1.38218.1.3.8
Compatible - Alarm period check in minutes.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..240  

pdu-DHCPStatus 1.3.6.1.4.1.38218.1.3.9
Compatible - DHCP Enable.Set to 1 to ENABLE or 0 to DISABLE DHCP support.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

pdu-IPAddress 1.3.6.1.4.1.38218.1.3.10
Compatible - pdu IP Address.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

pdu-SubNetMask 1.3.6.1.4.1.38218.1.3.11
Compatible - pdu Sub-net mask.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

pdu-CabinetID 1.3.6.1.4.1.38218.1.3.12
pdu Cabinet ID.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

pdu-socketPeriod 1.3.6.1.4.1.38218.1.3.13
pdu socket ON sequence period (mS) 0=OFF.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..5000  

pdu-LockPeriod 1.3.6.1.4.1.38218.1.3.14
pdu Lock activation period (S).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..240  

pdu-RTC-Hour 1.3.6.1.4.1.38218.1.3.15
pdu RTC Hour [24 hour clock].
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

pdu-RTC-Minute 1.3.6.1.4.1.38218.1.3.16
pdu RTC Minute.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..59  

pdu-RTC-Date 1.3.6.1.4.1.38218.1.3.17
pdu RTC Date.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

pdu-RTC-Month 1.3.6.1.4.1.38218.1.3.18
pdu RTC Month.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..12  

pdu-RTC-Year 1.3.6.1.4.1.38218.1.3.19
pdu RTC Year [tens only].
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..99  

trapDestinationsTable 1.3.6.1.4.1.38218.1.4.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TrapDestinationsEntry

trapDestinationsEntry 1.3.6.1.4.1.38218.1.4.1.1
Table of Trap notification destinations.
Status: current Access: not-accessible
OBJECT-TYPE    
  TrapDestinationsEntry  

trapDestinationsIndex 1.3.6.1.4.1.38218.1.4.1.1.1
Trap destination index [0..1].
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..1  

trapDestinationsStatus 1.3.6.1.4.1.38218.1.4.1.1.2
Trap destination status. Set to 1 to ENABLE or 0 to DISABLE trap destination.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

trapDestinationsIP 1.3.6.1.4.1.38218.1.4.1.1.3
Trap destination IP address. Set to the IP address of the destination SNMP manager.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

trapDestinationsCommunity 1.3.6.1.4.1.38218.1.4.1.1.4
Trap destination SNMP community. Set to the community name to be used with the destination SNMP manager.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

pdu-Firmware 1.3.6.1.4.1.38218.1.5.1
pdu Firmware version.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

pdu-Nosockets 1.3.6.1.4.1.38218.1.5.2
pdu Number of sockets.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..32  

pdu-ProductName 1.3.6.1.4.1.38218.1.5.3
pdu Product name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

pdu-SerialNumber 1.3.6.1.4.1.38218.1.5.4
pdu Serial number.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

pdu-meter1-VRMS 1.3.6.1.4.1.38218.1.6.1
pdu Meter 1 RMS Voltage (VAC) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-meter1-IRMS 1.3.6.1.4.1.38218.1.6.2
pdu Meter 1 RMS Current (A) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-meter1-KWH 1.3.6.1.4.1.38218.1.6.3
pdu Meter 1 total energy consumption (kW/h) x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

pdu-meter1-KW 1.3.6.1.4.1.38218.1.6.4
pdu Meter 1 Kilowatts (kW) x1000.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

pdu-meter1-TPMU 1.3.6.1.4.1.38218.1.6.5
pdu Meter 1 Internal Temperature (C) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-meter1-IPK 1.3.6.1.4.1.38218.1.6.6
pdu Meter 1 Peak Current (A) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-meter1-VPK 1.3.6.1.4.1.38218.1.6.7
pdu Meter 1 Peak Voltage (V) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-meter1-PF 1.3.6.1.4.1.38218.1.6.8
pdu Meter 1 Power Factor x1000
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-meter1-Freq 1.3.6.1.4.1.38218.1.6.9
pdu Meter 1 Frequency x10
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-meter2-VRMS 1.3.6.1.4.1.38218.1.6.10
pdu Meter 2 RMS Voltage (VAC) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-meter2-IRMS 1.3.6.1.4.1.38218.1.6.11
pdu Meter 2 RMS Current (A) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-meter2-KWH 1.3.6.1.4.1.38218.1.6.12
pdu Meter 2 total energy consumption (kW/h) x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

pdu-meter2-KW 1.3.6.1.4.1.38218.1.6.13
pdu Meter 2 Kilowatts (kW) x1000.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

pdu-meter2-TPMU 1.3.6.1.4.1.38218.1.6.14
pdu Meter 2 Internal Temperature (C) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-meter2-IPK 1.3.6.1.4.1.38218.1.6.15
pdu Meter 2 Peak Current (A) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-meter2-VPK 1.3.6.1.4.1.38218.1.6.16
pdu Meter 2 Peak Voltage (V) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-meter2-PF 1.3.6.1.4.1.38218.1.6.17
pdu Meter 2 Power Factor x1000
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-meter2-Freq 1.3.6.1.4.1.38218.1.6.18
pdu Meter 2 Frequency x10
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-meter3-VRMS 1.3.6.1.4.1.38218.1.6.19
pdu Meter 3 RMS Voltage (VAC) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-meter3-IRMS 1.3.6.1.4.1.38218.1.6.20
pdu Meter 3 RMS Current (A) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-meter3-KWH 1.3.6.1.4.1.38218.1.6.21
pdu Meter 3 total energy consumption (kW/h) x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

pdu-meter3-KW 1.3.6.1.4.1.38218.1.6.22
pdu Meter 3 Kilowatts (kW) x1000.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

pdu-meter3-TPMU 1.3.6.1.4.1.38218.1.6.23
pdu Meter 3 Internal Temperature (C) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-meter3-IPK 1.3.6.1.4.1.38218.1.6.24
pdu Meter 3 Peak Current (A) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-meter3-VPK 1.3.6.1.4.1.38218.1.6.25
pdu Meter 3 Peak Voltage (V) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-meter3-PF 1.3.6.1.4.1.38218.1.6.26
pdu Meter 3 Power Factor x1000
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-meter3-Freq 1.3.6.1.4.1.38218.1.6.27
pdu Meter 3 Frequency x10
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-socketsTable 1.3.6.1.4.1.38218.1.7.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Pdu-socketsEntry

pdu-socketsEntry 1.3.6.1.4.1.38218.1.7.1.1
Table of socket status parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  Pdu-socketsEntry  

socket-Index 1.3.6.1.4.1.38218.1.7.1.1.1
socket index
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..47  

socket-Number 1.3.6.1.4.1.38218.1.7.1.1.2
socket number [Range 1 to 48]
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

socket-Equipment 1.3.6.1.4.1.38218.1.7.1.1.3
socket equipment name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

socket-ONOFF 1.3.6.1.4.1.38218.1.7.1.1.4
socket ON/OFF status [Set to 1 to switch ON, 0 to switch OFF]
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1)  

socket-AMPS 1.3.6.1.4.1.38218.1.7.1.1.5
socket current (Amps) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

socket-KWH 1.3.6.1.4.1.38218.1.7.1.1.6
socket Energy (kWh) x10.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

socket-INFO 1.3.6.1.4.1.38218.1.7.1.1.7
socket information (status, phase and picture).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-environmental-Temp1 1.3.6.1.4.1.38218.1.8.1
Environmental Temperature probe 1 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-environmental-Temp1-Location 1.3.6.1.4.1.38218.1.8.2
Environmental Temperature probe 1 location name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

pdu-environmental-Temp2 1.3.6.1.4.1.38218.1.8.3
Environmental Temperature probe 2 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-environmental-Temp2-Location 1.3.6.1.4.1.38218.1.8.4
Environmental Temperature probe 2 location name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

pdu-environmental-Temp3 1.3.6.1.4.1.38218.1.8.5
Environmental Temperature probe 3 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-environmental-Temp3-Location 1.3.6.1.4.1.38218.1.8.6
Environmental Temperature probe 3 location name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

pdu-environmental-Temp4 1.3.6.1.4.1.38218.1.8.7
Environmental Temperature probe 4 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-environmental-Temp4-Location 1.3.6.1.4.1.38218.1.8.8
Environmental Temperature probe 4 location name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

pdu-environmental-Temp5 1.3.6.1.4.1.38218.1.8.9
Environmental Temperature probe 5 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-environmental-Temp5-Location 1.3.6.1.4.1.38218.1.8.10
Environmental Temperature probe 5 location name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

pdu-environmental-Temp6 1.3.6.1.4.1.38218.1.8.11
Environmental Temperature probe 6 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-environmental-Temp6-Location 1.3.6.1.4.1.38218.1.8.12
Environmental Temperature probe 6 location name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

pdu-environmental-Temp7 1.3.6.1.4.1.38218.1.8.13
Environmental Temperature probe 7 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-environmental-Temp7-Location 1.3.6.1.4.1.38218.1.8.14
Environmental Temperature probe 7 location name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

pdu-environmental-Temp8 1.3.6.1.4.1.38218.1.8.15
Environmental Temperature probe 8 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-environmental-Temp8-Location 1.3.6.1.4.1.38218.1.8.16
Environmental Temperature probe 8 location name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

pdu-environmental-HumidityTemp 1.3.6.1.4.1.38218.1.8.17
Environmental Humidity probe Temperature (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-environmental-Humidity 1.3.6.1.4.1.38218.1.8.18
Environmental humidity probe (%) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

pdu-environmental-Contact1 1.3.6.1.4.1.38218.1.8.19
Environmental contact input 1 status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER open(0), closed(1)  

pdu-environmental-Contact1-Location 1.3.6.1.4.1.38218.1.8.20
Environmental contact input 1 location name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

pdu-environmental-Contact2 1.3.6.1.4.1.38218.1.8.21
Environmental contact input 2 status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER open(0), closed(1)  

pdu-environmental-Contact2-Location 1.3.6.1.4.1.38218.1.8.22
Environmental contact input 2 location name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

pdu-environmental-Contact3 1.3.6.1.4.1.38218.1.8.23
Environmental contact input 3 status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER open(0), closed(1)  

pdu-environmental-Contact3-Location 1.3.6.1.4.1.38218.1.8.24
Environmental contact input 3 location name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

pdu-Security-Door 1.3.6.1.4.1.38218.1.9.1
Security door contact status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER open(0), closed(1)  

pdu-Security-Lock 1.3.6.1.4.1.38218.1.9.2
Security lock status [Set to 1 to unlock]
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER locked(0), unlocked(1)  

pdu-Security-Wild 1.3.6.1.4.1.38218.1.9.3
Security Card/PIN Wildcard status. Set with 1 to enable or 0 to disable Wildcard feature.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

pdu-Security-UnlockTimeDate 1.3.6.1.4.1.38218.1.9.4
Time and data of last unlock.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

pdu-SecurityTable 1.3.6.1.4.1.38218.1.9.5
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Pdu-SecurityEntry

pdu-SecurityEntry 1.3.6.1.4.1.38218.1.9.5.1
Table of pdu- Card/PIN codes.
Status: current Access: not-accessible
OBJECT-TYPE    
  Pdu-SecurityEntry  

pdu-Security-Index 1.3.6.1.4.1.38218.1.9.5.1.1
Security Card/PIN code index.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..32  

pdu-Security-Code 1.3.6.1.4.1.38218.1.9.5.1.2
Security Card/PIN number.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

pdu-Logs-Number 1.3.6.1.4.1.38218.1.10.1
Log file number of log lines stored.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

pdu-Logs-Index 1.3.6.1.4.1.38218.1.10.2
Log file line index pointer. Set to line to be read.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

pdu-Logs-Data 1.3.6.1.4.1.38218.1.10.3
Log file log line data.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

pdu-Logs-Clear 1.3.6.1.4.1.38218.1.10.4
Log file clear. Set with 1 to clear log file.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

meter1-VRMSLowAlarm 1.3.6.1.4.1.38218.1.11.1.1
Meter 1 Voltage LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter1-VRMSLow 1.3.6.1.4.1.38218.1.11.1.2
eter 1 Voltage LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter1-VRMSHighAlarm 1.3.6.1.4.1.38218.1.11.1.3
Meter 1 Voltage HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter1-VRMSHigh 1.3.6.1.4.1.38218.1.11.1.4
Meter 1 Voltage HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter1-IRMSLowAlarm 1.3.6.1.4.1.38218.1.11.1.5
Meter 1 Current LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter1-IRMSLow 1.3.6.1.4.1.38218.1.11.1.6
Meter 1 Current LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter1-IRMSHighAlarm 1.3.6.1.4.1.38218.1.11.1.7
Meter 1 Current HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter1-IRMSHigh 1.3.6.1.4.1.38218.1.11.1.8
Meter 1 Current HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter1-KWSLowAlarm 1.3.6.1.4.1.38218.1.11.1.9
Meter 1 Kilowatts LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter1-KWSLow 1.3.6.1.4.1.38218.1.11.1.10
Meter 1 Kilowatts LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter1-KWSHighAlarm 1.3.6.1.4.1.38218.1.11.1.11
Meter 1 Kilowatts HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter1-KWSHigh 1.3.6.1.4.1.38218.1.11.1.12
Meter 1 Kilowatts HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter1-TempLowAlarm 1.3.6.1.4.1.38218.1.11.1.13
Meter 1 Internal temperature LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter1-TempLow 1.3.6.1.4.1.38218.1.11.1.14
Meter 1 Internal temperature LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter1-TempHighAlarm 1.3.6.1.4.1.38218.1.11.1.15
Meter 1 Internal temperature HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter1-TempHigh 1.3.6.1.4.1.38218.1.11.1.16
Meter 1 Internal temperature HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter1-PFLowAlarm 1.3.6.1.4.1.38218.1.11.1.17
Meter 1 Power factor LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter1-PFLow 1.3.6.1.4.1.38218.1.11.1.18
Meter 1 Power factor LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter1-PFHighAlarm 1.3.6.1.4.1.38218.1.11.1.19
Meter 1 Power factor HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter1-PFHigh 1.3.6.1.4.1.38218.1.11.1.20
Meter 1 Power factor HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter1-FreqLowAlarm 1.3.6.1.4.1.38218.1.11.1.21
Meter 1 Frequency LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter1-FreqLow 1.3.6.1.4.1.38218.1.11.1.22
Meter 1 Frequency LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter1-FreqHighAlarm 1.3.6.1.4.1.38218.1.11.1.23
Meter 1 Frequency HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter1-FreqHigh 1.3.6.1.4.1.38218.1.11.1.24
Meter 1 Frequency HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter2-VRMSLowAlarm 1.3.6.1.4.1.38218.1.11.1.25
Meter 2 Voltage LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter2-VRMSLow 1.3.6.1.4.1.38218.1.11.1.26
eter 1 Voltage LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter2-VRMSHighAlarm 1.3.6.1.4.1.38218.1.11.1.27
Meter 2 Voltage HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter2-VRMSHigh 1.3.6.1.4.1.38218.1.11.1.28
Meter 2 Voltage HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter2-IRMSLowAlarm 1.3.6.1.4.1.38218.1.11.1.29
Meter 2 Current LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter2-IRMSLow 1.3.6.1.4.1.38218.1.11.1.30
Meter 2 Current LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter2-IRMSHighAlarm 1.3.6.1.4.1.38218.1.11.1.31
Meter 2 Current HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter2-IRMSHigh 1.3.6.1.4.1.38218.1.11.1.32
Meter 2 Current HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter2-KWSLowAlarm 1.3.6.1.4.1.38218.1.11.1.33
Meter 2 Kilowatts LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter2-KWSLow 1.3.6.1.4.1.38218.1.11.1.34
Meter 2 Kilowatts LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter2-KWSHighAlarm 1.3.6.1.4.1.38218.1.11.1.35
Meter 2 Kilowatts HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter2-KWSHigh 1.3.6.1.4.1.38218.1.11.1.36
Meter 2 Kilowatts HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter2-TempLowAlarm 1.3.6.1.4.1.38218.1.11.1.37
Meter 2 Internal temperature LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter2-TempLow 1.3.6.1.4.1.38218.1.11.1.38
Meter 2 Internal temperature LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter2-TempHighAlarm 1.3.6.1.4.1.38218.1.11.1.39
Meter 2 Internal temperature HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter2-TempHigh 1.3.6.1.4.1.38218.1.11.1.40
Meter 2 Internal temperature HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter2-PFLowAlarm 1.3.6.1.4.1.38218.1.11.1.41
Meter 2 Power factor LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter2-PFLow 1.3.6.1.4.1.38218.1.11.1.42
Meter 2 Power factor LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter2-PFHighAlarm 1.3.6.1.4.1.38218.1.11.1.43
Meter 2 Power factor HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter2-PFHigh 1.3.6.1.4.1.38218.1.11.1.44
Meter 2 Power factor HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter2-FreqLowAlarm 1.3.6.1.4.1.38218.1.11.1.45
Meter 2 Frequency LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter2-FreqLow 1.3.6.1.4.1.38218.1.11.1.46
Meter 2 Frequency LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter2-FreqHighAlarm 1.3.6.1.4.1.38218.1.11.1.47
Meter 2 Frequency HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter2-FreqHigh 1.3.6.1.4.1.38218.1.11.1.48
Meter 2 Frequency HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter3-VRMSLowAlarm 1.3.6.1.4.1.38218.1.11.1.49
Meter 3 Voltage LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter3-VRMSLow 1.3.6.1.4.1.38218.1.11.1.50
eter 1 Voltage LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter3-VRMSHighAlarm 1.3.6.1.4.1.38218.1.11.1.51
Meter 3 Voltage HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter3-VRMSHigh 1.3.6.1.4.1.38218.1.11.1.52
Meter 3 Voltage HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter3-IRMSLowAlarm 1.3.6.1.4.1.38218.1.11.1.53
Meter 3 Current LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter3-IRMSLow 1.3.6.1.4.1.38218.1.11.1.54
Meter 3 Current LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter3-IRMSHighAlarm 1.3.6.1.4.1.38218.1.11.1.55
Meter 3 Current HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter3-IRMSHigh 1.3.6.1.4.1.38218.1.11.1.56
Meter 3 Current HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter3-KWSLowAlarm 1.3.6.1.4.1.38218.1.11.1.57
Meter 3 Kilowatts LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter3-KWSLow 1.3.6.1.4.1.38218.1.11.1.58
Meter 3 Kilowatts LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter3-KWSHighAlarm 1.3.6.1.4.1.38218.1.11.1.59
Meter 3 Kilowatts HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter3-KWSHigh 1.3.6.1.4.1.38218.1.11.1.60
Meter 3 Kilowatts HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter3-TempLowAlarm 1.3.6.1.4.1.38218.1.11.1.61
Meter 3 Internal temperature LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter3-TempLow 1.3.6.1.4.1.38218.1.11.1.62
Meter 3 Internal temperature LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter3-TempHighAlarm 1.3.6.1.4.1.38218.1.11.1.63
Meter 3 Internal temperature HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter3-TempHigh 1.3.6.1.4.1.38218.1.11.1.64
Meter 3 Internal temperature HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter3-PFLowAlarm 1.3.6.1.4.1.38218.1.11.1.65
Meter 3 Power factor LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter3-PFLow 1.3.6.1.4.1.38218.1.11.1.66
Meter 3 Power factor LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter3-PFHighAlarm 1.3.6.1.4.1.38218.1.11.1.67
Meter 3 Power factor HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter3-PFHigh 1.3.6.1.4.1.38218.1.11.1.68
Meter 3 Power factor HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter3-FreqLowAlarm 1.3.6.1.4.1.38218.1.11.1.69
Meter 3 Frequency LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter3-FreqLow 1.3.6.1.4.1.38218.1.11.1.70
Meter 3 Frequency LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

meter3-FreqHighAlarm 1.3.6.1.4.1.38218.1.11.1.71
Meter 3 Frequency HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

meter3-FreqHigh 1.3.6.1.4.1.38218.1.11.1.72
Meter 3 Frequency HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

socket-ThresholdsTable 1.3.6.1.4.1.38218.1.11.1.73
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Socket-ThresholdsEntry

socket-ThresholdsEntry 1.3.6.1.4.1.38218.1.11.1.73.1
Table of socket trap notification thresholds.
Status: current Access: not-accessible
OBJECT-TYPE    
  Socket-ThresholdsEntry  

socket-ThresholdsNumber 1.3.6.1.4.1.38218.1.11.1.73.1.1
Trap threshold socket- number [1..48].
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..48  

socket-AMPSLowAlarm 1.3.6.1.4.1.38218.1.11.1.73.1.2
socket Current LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

socket-AMPSLow 1.3.6.1.4.1.38218.1.11.1.73.1.3
socket Current LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

socket-AMPSHighAlarm 1.3.6.1.4.1.38218.1.11.1.73.1.4
socket Current HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

socket-AMPSHigh 1.3.6.1.4.1.38218.1.11.1.73.1.5
socket Current HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-Temp1LowAlarm 1.3.6.1.4.1.38218.1.11.1.74
Environmental temperature probe 1 LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Temp1Low 1.3.6.1.4.1.38218.1.11.1.75
Environmental temperature probe 1 LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-Temp1HighAlarm 1.3.6.1.4.1.38218.1.11.1.76
Environmental temperature probe 1 HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Temp1High 1.3.6.1.4.1.38218.1.11.1.77
Environmental temperature probe 1 HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-Temp2LowAlarm 1.3.6.1.4.1.38218.1.11.1.78
Environmental temperature probe 2 LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Temp2Low 1.3.6.1.4.1.38218.1.11.1.79
Environmental temperature probe 2 LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-Temp2HighAlarm 1.3.6.1.4.1.38218.1.11.1.80
Environmental temperature probe 2 HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Temp2High 1.3.6.1.4.1.38218.1.11.1.81
Environmental temperature probe 2 HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-Temp3LowAlarm 1.3.6.1.4.1.38218.1.11.1.82
Environmental temperature probe 3 LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Temp3Low 1.3.6.1.4.1.38218.1.11.1.83
Environmental temperature probe 3 LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-Temp3HighAlarm 1.3.6.1.4.1.38218.1.11.1.84
Environmental temperature probe 3 HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Temp3High 1.3.6.1.4.1.38218.1.11.1.85
Environmental temperature probe 3 HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-Temp4LowAlarm 1.3.6.1.4.1.38218.1.11.1.86
Environmental temperature probe 4 LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Temp4Low 1.3.6.1.4.1.38218.1.11.1.87
Environmental temperature probe 4 LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-Temp4HighAlarm 1.3.6.1.4.1.38218.1.11.1.88
Environmental temperature probe 4 HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Temp4High 1.3.6.1.4.1.38218.1.11.1.89
Environmental temperature probe 4 HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-Temp5LowAlarm 1.3.6.1.4.1.38218.1.11.1.90
Environmental temperature probe 5 LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Temp5Low 1.3.6.1.4.1.38218.1.11.1.91
Environmental temperature probe 5 LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-Temp5HighAlarm 1.3.6.1.4.1.38218.1.11.1.92
Environmental temperature probe 5 HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Temp5High 1.3.6.1.4.1.38218.1.11.1.93
Environmental temperature probe 5 HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-Temp6LowAlarm 1.3.6.1.4.1.38218.1.11.1.94
Environmental temperature probe 6 LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Temp6Low 1.3.6.1.4.1.38218.1.11.1.95
Environmental temperature probe 6 LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-Temp6HighAlarm 1.3.6.1.4.1.38218.1.11.1.96
Environmental temperature probe 6 HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Temp6High 1.3.6.1.4.1.38218.1.11.1.97
Environmental temperature probe 6 HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-Temp7LowAlarm 1.3.6.1.4.1.38218.1.11.1.98
Environmental temperature probe 7 LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Temp7Low 1.3.6.1.4.1.38218.1.11.1.99
Environmental temperature probe 7 LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-Temp7HighAlarm 1.3.6.1.4.1.38218.1.11.1.100
Environmental temperature probe 7 HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Temp7High 1.3.6.1.4.1.38218.1.11.1.101
Environmental temperature probe 7 HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-Temp8LowAlarm 1.3.6.1.4.1.38218.1.11.1.102
Environmental temperature probe 8 LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Temp8Low 1.3.6.1.4.1.38218.1.11.1.103
Environmental temperature probe 8 LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-Temp8HighAlarm 1.3.6.1.4.1.38218.1.11.1.104
Environmental temperature probe 8 HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Temp8High 1.3.6.1.4.1.38218.1.11.1.105
Environmental temperature probe 8 HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-HumidityTempLowAlarm 1.3.6.1.4.1.38218.1.11.1.106
Environmental humidity probe temperature LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-HumidityTempLow 1.3.6.1.4.1.38218.1.11.1.107
Environmental humidity probe temperature LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-HumidityTempHighAlarm 1.3.6.1.4.1.38218.1.11.1.108
Environmental humidity probe temperature HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-HumidityTempHigh 1.3.6.1.4.1.38218.1.11.1.109
Environmental humidity probe temperature HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-HumidityLowAlarm 1.3.6.1.4.1.38218.1.11.1.110
Environmental humidity probe LOW alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-HumidityLow 1.3.6.1.4.1.38218.1.11.1.111
Environmental humidity probe LOW trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-HumidityHighAlarm 1.3.6.1.4.1.38218.1.11.1.112
Environmental humidity probe HIGH alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-HumidityHigh 1.3.6.1.4.1.38218.1.11.1.113
Environmental humidity probe HIGH trap threshold x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

environmental-Contact1OpenedAlarm 1.3.6.1.4.1.38218.1.11.1.114
Environmental Contact 1 OPENED alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Contact1ClosedAlarm 1.3.6.1.4.1.38218.1.11.1.115
Environmental Contact 1 CLOSED alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Contact2OpenedAlarm 1.3.6.1.4.1.38218.1.11.1.116
Environmental Contact 2 OPENED alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Contact2ClosedAlarm 1.3.6.1.4.1.38218.1.11.1.117
Environmental Contact 2 CLOSED alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Contact3OpenedAlarm 1.3.6.1.4.1.38218.1.11.1.118
Environmental Contact 3 OPENED alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

environmental-Contact3ClosedAlarm 1.3.6.1.4.1.38218.1.11.1.119
Environmental Contact 3 CLOSED alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

security-DoorOpenedAlarm 1.3.6.1.4.1.38218.1.11.1.120
Security Door OPENED alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

security-DoorClosedAlarm 1.3.6.1.4.1.38218.1.11.1.121
Security Door CLOSED alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

security-LockUnlockedAlarm 1.3.6.1.4.1.38218.1.11.1.122
Security Lock UNLOCKED alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

security-LockLockedAlarm 1.3.6.1.4.1.38218.1.11.1.123
Security Lock LOCKED alarm disabled/enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

slave-slaveSelected 1.3.6.1.4.1.38218.2.1
Compatible - Currently selected slave pdu. Set to number between 1 and slave-Nopdus
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..32  

slave-pduName 1.3.6.1.4.1.38218.2.2.1
Compatible - slave pdu Name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

slave-pduStatus 1.3.6.1.4.1.38218.2.2.2
Compatible - slave pdu ONLINE / OFFLINE or DISABLED status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER offline(0), online(1), disabled(2)  

slave-pduAddress 1.3.6.1.4.1.38218.2.2.3
Compatible - slave pdu MODBUS Address.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..32  

slave-pduFirmware 1.3.6.1.4.1.38218.2.2.4
Compatible - slave pdu Firmware version.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

slave-Info-NotUsed2 1.3.6.1.4.1.38218.2.2.5
Compatible - Not used.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

slave-pduNosockets 1.3.6.1.4.1.38218.2.2.6
Compatible - slave pdu Number of sockets.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..48  

slave-Info-NotUsed3 1.3.6.1.4.1.38218.2.2.7
Compatible - Not used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Info-NotUsed4 1.3.6.1.4.1.38218.2.2.8
Compatible - Not used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Info-pduReset 1.3.6.1.4.1.38218.2.2.9
Compatible - slave pdu Reset.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

slave-Info-pdukWhReset 1.3.6.1.4.1.38218.2.2.10
Compatible - slave pdu Reset energy.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

slave-meter1-VRMS 1.3.6.1.4.1.38218.2.3.1
Compatible - slave Meter 1 RMS Voltage (VAC) x10.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

slave-meter1-IRMS 1.3.6.1.4.1.38218.2.3.2
Compatible - slave Meter 1 RMS Current (A) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-meter1-KWH 1.3.6.1.4.1.38218.2.3.3
Compatible - slave Meter 1 total energy consumption (kW/h) x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-meter1-KW 1.3.6.1.4.1.38218.2.3.4
Compatible - slave Meter 1 Kilowatts (kW) x1000.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-meter1-TPMU 1.3.6.1.4.1.38218.2.3.5
Compatible - slave Meter 1 Internal Temperature (C) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Status-NotUsed1 1.3.6.1.4.1.38218.2.3.6
Compatible - Not used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Status-NotUsed2 1.3.6.1.4.1.38218.2.3.7
Compatible - Not used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-meter1-IPK 1.3.6.1.4.1.38218.2.3.8
Compatible - slave Meter 1 Peak Current (A) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-meter1-VPK 1.3.6.1.4.1.38218.2.3.9
Compatible - slave Meter 1 Peak Voltage (V) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-meter1-PF 1.3.6.1.4.1.38218.2.3.10
Compatible - slave Meter 1 Power Factor x1000
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Status-NotUsed3 1.3.6.1.4.1.38218.2.3.11
Compatible - Not used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Status-NotUsed4 1.3.6.1.4.1.38218.2.3.12
Compatible - Not used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Status-NotUsed5 1.3.6.1.4.1.38218.2.3.13
Compatible - Not used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-meter1-Freq 1.3.6.1.4.1.38218.2.3.14
Compatible - slave Meter 1 Frequency x10
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-meter2-VRMS 1.3.6.1.4.1.38218.2.3.15
Compatible - slave Meter 2 RMS Voltage (VAC) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-meter2-IRMS 1.3.6.1.4.1.38218.2.3.16
Compatible - slave Meter 2 RMS Current (A) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-meter2-KWH 1.3.6.1.4.1.38218.2.3.17
Compatible - slave Meter 2 total energy consumption (kW/h) x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-meter2-KW 1.3.6.1.4.1.38218.2.3.18
Compatible - slave Meter 2 Kilowatts (kW) x1000.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-meter2-TPMU 1.3.6.1.4.1.38218.2.3.19
Compatible - slave Meter 2 Internal Temperature (C) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-meter2-IPK 1.3.6.1.4.1.38218.2.3.20
Compatible - slave Meter 2 Peak Current (A) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-meter2-VPK 1.3.6.1.4.1.38218.2.3.21
Compatible - slave Meter 2 Peak Voltage (V) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-meter2-PF 1.3.6.1.4.1.38218.2.3.22
Compatible - slave Meter 2 Power Factor x1000
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-meter2-Freq 1.3.6.1.4.1.38218.2.3.23
Compatible - slave Meter 2 Frequency x10
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-meter3-VRMS 1.3.6.1.4.1.38218.2.3.24
Compatible - slave Meter 3 RMS Voltage (VAC) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-meter3-IRMS 1.3.6.1.4.1.38218.2.3.25
Compatible - slave Meter 3 RMS Current (A) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-meter3-KWH 1.3.6.1.4.1.38218.2.3.26
Compatible - slave Meter 3 total energy consumption (kW/h) x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-meter3-KW 1.3.6.1.4.1.38218.2.3.27
Compatible - slave Meter 3 Kilowatts (kW) x1000.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-meter3-TPMU 1.3.6.1.4.1.38218.2.3.28
Compatible - slave Meter 3 Internal Temperature (C) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-meter3-IPK 1.3.6.1.4.1.38218.2.3.29
Compatible - slave Meter 3 Peak Current (A) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-meter3-VPK 1.3.6.1.4.1.38218.2.3.30
Compatible - slave Meter 3 Peak Voltage (V) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-meter3-PF 1.3.6.1.4.1.38218.2.3.31
Compatible - slave Meter 3 Power Factor x1000
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-meter3-Freq 1.3.6.1.4.1.38218.2.3.32
Compatible - slave Meter 3 Frequency x10
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-socketsTable 1.3.6.1.4.1.38218.2.4.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Slave-socketsEntry

slave-socketsEntry 1.3.6.1.4.1.38218.2.4.1.1
Table of socket status parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  Slave-socketsEntry  

slave-socket-Index 1.3.6.1.4.1.38218.2.4.1.1.1
socket index
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..48  

slave-socket-Number 1.3.6.1.4.1.38218.2.4.1.1.2
socket number [Range 1 to 48]
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER  

slave-socket-NotUsed1 1.3.6.1.4.1.38218.2.4.1.1.3
Compatible - Not used.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

slave-socket-ONOFF 1.3.6.1.4.1.38218.2.4.1.1.4
socket ON/OFF status [Compatible - Write ignored]
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1)  

slave-socket-AMPS 1.3.6.1.4.1.38218.2.4.1.1.5
socket current (Amps) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-socket-KWH 1.3.6.1.4.1.38218.2.4.1.1.6
socket Energy (kWh) x10.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

socket-Selected 1.3.6.1.4.1.38218.2.4.2
Compatible - Currently selected socket. Set to number between 1 and slave-pduNosockets
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..48  

socket-AllON 1.3.6.1.4.1.38218.2.4.3
Set all sockets in system to ON.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1  

socket-AllOFF 1.3.6.1.4.1.38218.2.4.4
Set all sockets in system to OFF.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1  

slave-environmental-Temp1 1.3.6.1.4.1.38218.2.5.1
Compatible - Environmental Temperature probe 1 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-environmental-Temp2 1.3.6.1.4.1.38218.2.5.2
Compatible - Environmental Temperature probe 2 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-environmental-Temp3 1.3.6.1.4.1.38218.2.5.3
Compatible - Environmental Temperature probe 3 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-environmental-Temp4 1.3.6.1.4.1.38218.2.5.4
Compatible - Environmental Temperature probe 4 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-environmental-Temp5 1.3.6.1.4.1.38218.2.5.5
Compatible - Environmental Temperature probe 5 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-environmental-Temp6 1.3.6.1.4.1.38218.2.5.6
Compatible - Environmental Temperature probe 6 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-environmental-Temp7 1.3.6.1.4.1.38218.2.5.7
Compatible - Environmental Temperature probe 7 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-environmental-Temp8 1.3.6.1.4.1.38218.2.5.8
Compatible - Environmental Temperature probe 8 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-environmental-HumidityTemp 1.3.6.1.4.1.38218.2.5.9
Compatible - Environmental Humidity probe Temperature (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-environmental-Humidity 1.3.6.1.4.1.38218.2.5.10
Compatible - Environmental humidity probe (%) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-environmental-Contact1 1.3.6.1.4.1.38218.2.5.11
Compatible - Environmental contact input 1 status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER open(0), closed(1)  

slave-environmental-Contact2 1.3.6.1.4.1.38218.2.5.12
Compatible - Environmental contact input 2 status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER open(0), closed(1)  

slave-environmental-Contact3 1.3.6.1.4.1.38218.2.5.13
Compatible - Environmental contact input 3 status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER open(0), closed(1)  

slave-Security-Door 1.3.6.1.4.1.38218.2.6.1
Compatible - Security door contact status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER open(0), closed(1)  

slave-Security-Lock 1.3.6.1.4.1.38218.2.6.2
Compatible - Security lock status. Set with any data to force unlock.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER locked(0), unlocked(1)  

slave-Set-meter1-VRMSLow 1.3.6.1.4.1.38218.2.7.1.1
Meter 1 Voltage LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter1-VRMSHigh 1.3.6.1.4.1.38218.2.7.1.2
Meter 1 Voltage HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter1-IRMSLow 1.3.6.1.4.1.38218.2.7.1.3
Meter 1 Amps LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter1-IRMSHigh 1.3.6.1.4.1.38218.2.7.1.4
Meter 1 Amps HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter1-KWSLow 1.3.6.1.4.1.38218.2.7.1.5
Meter 1 Kilowatts LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter1-KWSHigh 1.3.6.1.4.1.38218.2.7.1.6
Meter 1 Kilowatts HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter1-TempLow 1.3.6.1.4.1.38218.2.7.1.7
Meter 1 Temperature LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter1-TempHigh 1.3.6.1.4.1.38218.2.7.1.8
Meter 1 Temperature HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-socket-AMPSLow 1.3.6.1.4.1.38218.2.7.1.9
socket Amps LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-socket-AMPSHigh 1.3.6.1.4.1.38218.2.7.1.10
socket Amps HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Temp1Low 1.3.6.1.4.1.38218.2.7.1.11
Environmental Temperature probe 1 LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Temp1High 1.3.6.1.4.1.38218.2.7.1.12
Environmental Temperature probe 1 HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Temp2Low 1.3.6.1.4.1.38218.2.7.1.13
Environmental Temperature probe 2 LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Temp2High 1.3.6.1.4.1.38218.2.7.1.14
Environmental Temperature probe 2 HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Temp3Low 1.3.6.1.4.1.38218.2.7.1.15
Environmental Temperature probe 3 LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Temp3High 1.3.6.1.4.1.38218.2.7.1.16
Environmental Temperature probe 3 HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Temp4Low 1.3.6.1.4.1.38218.2.7.1.17
Environmental Temperature probe 4 LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Temp4High 1.3.6.1.4.1.38218.2.7.1.18
Environmental Temperature probe 4 HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Temp5Low 1.3.6.1.4.1.38218.2.7.1.19
Environmental Temperature probe 5 LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Temp5High 1.3.6.1.4.1.38218.2.7.1.20
Environmental Temperature probe 5 HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Temp6Low 1.3.6.1.4.1.38218.2.7.1.21
Environmental Temperature probe 6 LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Temp6High 1.3.6.1.4.1.38218.2.7.1.22
Environmental Temperature probe 6 HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Temp7Low 1.3.6.1.4.1.38218.2.7.1.23
Environmental Temperature probe 7 LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Temp7High 1.3.6.1.4.1.38218.2.7.1.24
Environmental Temperature probe 7 HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Temp8Low 1.3.6.1.4.1.38218.2.7.1.25
Environmental Temperature probe 8 LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Temp8High 1.3.6.1.4.1.38218.2.7.1.26
Environmental Temperature probe 8 HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-HumidityTempLow 1.3.6.1.4.1.38218.2.7.1.27
Environmental Humidity probe Temperature LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-HumidityTempHigh 1.3.6.1.4.1.38218.2.7.1.28
Environmental Humidity probe Temperature HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-HumidityLow 1.3.6.1.4.1.38218.2.7.1.29
Environmental Humidity probe LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-HumidityHigh 1.3.6.1.4.1.38218.2.7.1.30
Environmental Humidity probe HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Contact1Open 1.3.6.1.4.1.38218.2.7.1.31
Environmental Contact 1 OPEN trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Contact1Closed 1.3.6.1.4.1.38218.2.7.1.32
Environmental Contact 1 CLOSED trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Contact2Open 1.3.6.1.4.1.38218.2.7.1.33
Environmental Contact 2 OPEN trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Contact2Closed 1.3.6.1.4.1.38218.2.7.1.34
Environmental Contact 2 CLOSED trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Contact3Open 1.3.6.1.4.1.38218.2.7.1.35
Environmental Contact 3 OPEN trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-environmental-Contact3Closed 1.3.6.1.4.1.38218.2.7.1.36
Environmental Contact 3 CLOSED trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-Security-DoorOpen 1.3.6.1.4.1.38218.2.7.1.37
Environmental Door OPEN trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-Security-DoorClosed 1.3.6.1.4.1.38218.2.7.1.38
Environmental Door CLOSED trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-Security-LockUnlocked 1.3.6.1.4.1.38218.2.7.1.39
Environmental Lock UNLOCKED trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-Security-LockLocked 1.3.6.1.4.1.38218.2.7.1.40
Environmental Lock LOCKED trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-pduOffline 1.3.6.1.4.1.38218.2.7.1.41
pdu OFFLINE trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter1-PFLow 1.3.6.1.4.1.38218.2.7.1.42
Meter 1 Power Factor LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter1-PFHigh 1.3.6.1.4.1.38218.2.7.1.43
Meter 1 Power Factor HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter1-FreqLow 1.3.6.1.4.1.38218.2.7.1.44
Meter 1 Frequency LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter1-FreqHigh 1.3.6.1.4.1.38218.2.7.1.45
Meter 1 Frequency HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter2-VRMSLow 1.3.6.1.4.1.38218.2.7.1.46
Meter 2 Voltage LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter2-VRMSHigh 1.3.6.1.4.1.38218.2.7.1.47
Meter 2 Voltage HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter2-IRMSLow 1.3.6.1.4.1.38218.2.7.1.48
Meter 2 Amps LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter2-IRMSHigh 1.3.6.1.4.1.38218.2.7.1.49
Meter 2 Amps HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter2-KWSLow 1.3.6.1.4.1.38218.2.7.1.50
Meter 2 Kilowatts LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter2-KWSHigh 1.3.6.1.4.1.38218.2.7.1.51
Meter 2 Kilowatts HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter2-TempLow 1.3.6.1.4.1.38218.2.7.1.52
Meter 2 Temperature LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter2-TempHigh 1.3.6.1.4.1.38218.2.7.1.53
Meter 2 Temperature HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter2-PFLow 1.3.6.1.4.1.38218.2.7.1.54
Meter 2 Power Factor LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter2-PFHigh 1.3.6.1.4.1.38218.2.7.1.55
Meter 2 Power Factor HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter2-FreqLow 1.3.6.1.4.1.38218.2.7.1.56
Meter 2 Frequency LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter2-FreqHigh 1.3.6.1.4.1.38218.2.7.1.57
Meter 2 Frequency HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter3-VRMSLow 1.3.6.1.4.1.38218.2.7.1.58
Meter 3 Voltage LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter3-VRMSHigh 1.3.6.1.4.1.38218.2.7.1.59
Meter 3 Voltage HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter3-IRMSLow 1.3.6.1.4.1.38218.2.7.1.60
Meter 3 Amps LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter3-IRMSHigh 1.3.6.1.4.1.38218.2.7.1.61
Meter 3 Amps HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter3-KWSLow 1.3.6.1.4.1.38218.2.7.1.62
Meter 3 Kilowatts LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter3-KWSHigh 1.3.6.1.4.1.38218.2.7.1.63
Meter 3 Kilowatts HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter3-TempLow 1.3.6.1.4.1.38218.2.7.1.64
Meter 3 Temperature LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter3-TempHigh 1.3.6.1.4.1.38218.2.7.1.65
Meter 3 Temperature HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter3-PFLow 1.3.6.1.4.1.38218.2.7.1.66
Meter 3 Power Factor LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter3-PFHigh 1.3.6.1.4.1.38218.2.7.1.67
Meter 3 Power Factor HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter3-FreqLow 1.3.6.1.4.1.38218.2.7.1.68
Meter 3 Frequency LOW trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Set-meter3-FreqHigh 1.3.6.1.4.1.38218.2.7.1.69
Meter 3 Frequency HIGH trap SET notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter1-VRMSLow 1.3.6.1.4.1.38218.2.7.2.1
Meter 1 Voltage LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter1-VRMSHigh 1.3.6.1.4.1.38218.2.7.2.2
Meter 1 Voltage HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter1-IRMSLow 1.3.6.1.4.1.38218.2.7.2.3
Meter 1 Amps LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter1-IRMSHigh 1.3.6.1.4.1.38218.2.7.2.4
Meter 1 Amps HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter1-KWSLow 1.3.6.1.4.1.38218.2.7.2.5
Meter 1 Kilowatts LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter1-KWSHigh 1.3.6.1.4.1.38218.2.7.2.6
Meter 1 Kilowatts HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter1-TempLow 1.3.6.1.4.1.38218.2.7.2.7
Meter 1 Temperature LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter1-TempHigh 1.3.6.1.4.1.38218.2.7.2.8
Meter 1 Temperature HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-socket-AMPSLow 1.3.6.1.4.1.38218.2.7.2.9
socket Amps LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-socket-AMPSHigh 1.3.6.1.4.1.38218.2.7.2.10
socket Amps HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Temp1Low 1.3.6.1.4.1.38218.2.7.2.11
Environmental Temperature probe 1 LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Temp1High 1.3.6.1.4.1.38218.2.7.2.12
Environmental Temperature probe 1 HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Temp2Low 1.3.6.1.4.1.38218.2.7.2.13
Environmental Temperature probe 2 LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Temp2High 1.3.6.1.4.1.38218.2.7.2.14
Environmental Temperature probe 2 HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Temp3Low 1.3.6.1.4.1.38218.2.7.2.15
Environmental Temperature probe 3 LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Temp3High 1.3.6.1.4.1.38218.2.7.2.16
Environmental Temperature probe 3 HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Temp4Low 1.3.6.1.4.1.38218.2.7.2.17
Environmental Temperature probe 4 LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Temp4High 1.3.6.1.4.1.38218.2.7.2.18
Environmental Temperature probe 4 HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Temp5Low 1.3.6.1.4.1.38218.2.7.2.19
Environmental Temperature probe 5 LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Temp5High 1.3.6.1.4.1.38218.2.7.2.20
Environmental Temperature probe 5 HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Temp6Low 1.3.6.1.4.1.38218.2.7.2.21
Environmental Temperature probe 6 LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Temp6High 1.3.6.1.4.1.38218.2.7.2.22
Environmental Temperature probe 6 HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Temp7Low 1.3.6.1.4.1.38218.2.7.2.23
Environmental Temperature probe 7 LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Temp7High 1.3.6.1.4.1.38218.2.7.2.24
Environmental Temperature probe 7 HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Temp8Low 1.3.6.1.4.1.38218.2.7.2.25
Environmental Temperature probe 8 LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Temp8High 1.3.6.1.4.1.38218.2.7.2.26
Environmental Temperature probe 8 HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-HumidityTempLow 1.3.6.1.4.1.38218.2.7.2.27
Environmental Humidity probe Temperature LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-HumidityTempHigh 1.3.6.1.4.1.38218.2.7.2.28
Environmental Humidity probe Temperature HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-HumidityLow 1.3.6.1.4.1.38218.2.7.2.29
Environmental Humidity probe LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-HumidityHigh 1.3.6.1.4.1.38218.2.7.2.30
Environmental Humidity probe HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Contact1Open 1.3.6.1.4.1.38218.2.7.2.31
Environmental Contact 1 OPEN trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Contact1Closed 1.3.6.1.4.1.38218.2.7.2.32
Environmental Contact 1 CLOSED trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Contact2Open 1.3.6.1.4.1.38218.2.7.2.33
Environmental Contact 2 OPEN trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Contact2Closed 1.3.6.1.4.1.38218.2.7.2.34
Environmental Contact 2 CLOSED trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Contact3Open 1.3.6.1.4.1.38218.2.7.2.35
Environmental Contact 3 OPEN trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-environmental-Contact3Closed 1.3.6.1.4.1.38218.2.7.2.36
Environmental Contact 3 CLOSED trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-Security-DoorOpen 1.3.6.1.4.1.38218.2.7.2.37
Environmental Door OPEN trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-Security-DoorClosed 1.3.6.1.4.1.38218.2.7.2.38
Environmental Door CLOSED trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-Security-LockUnlocked 1.3.6.1.4.1.38218.2.7.2.39
Environmental Lock UNLOCKED trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-Security-LockLocked 1.3.6.1.4.1.38218.2.7.2.40
Environmental Lock LOCKED trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-pduOffline 1.3.6.1.4.1.38218.2.7.2.41
pdu OFFLINE trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter1-PFLow 1.3.6.1.4.1.38218.2.7.2.42
Meter 1 Power Factor LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter1-PFHigh 1.3.6.1.4.1.38218.2.7.2.43
Meter 1 Power Factor HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter1-FreqLow 1.3.6.1.4.1.38218.2.7.2.44
Meter 1 Frequency LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter1-FreqHigh 1.3.6.1.4.1.38218.2.7.2.45
Meter 1 Frequency HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter2-VRMSLow 1.3.6.1.4.1.38218.2.7.2.46
Meter 2 Voltage LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter2-VRMSHigh 1.3.6.1.4.1.38218.2.7.2.47
Meter 2 Voltage HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter2-IRMSLow 1.3.6.1.4.1.38218.2.7.2.48
Meter 2 Amps LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter2-IRMSHigh 1.3.6.1.4.1.38218.2.7.2.49
Meter 2 Amps HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter2-KWSLow 1.3.6.1.4.1.38218.2.7.2.50
Meter 2 Kilowatts LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter2-KWSHigh 1.3.6.1.4.1.38218.2.7.2.51
Meter 2 Kilowatts HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter2-TempLow 1.3.6.1.4.1.38218.2.7.2.52
Meter 2 Temperature LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter2-TempHigh 1.3.6.1.4.1.38218.2.7.2.53
Meter 2 Temperature HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter2-PFLow 1.3.6.1.4.1.38218.2.7.2.54
Meter 2 Power Factor LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter2-PFHigh 1.3.6.1.4.1.38218.2.7.2.55
Meter 2 Power Factor HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter2-FreqLow 1.3.6.1.4.1.38218.2.7.2.56
Meter 2 Frequency LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter2-FreqHigh 1.3.6.1.4.1.38218.2.7.2.57
Meter 2 Frequency HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter3-VRMSLow 1.3.6.1.4.1.38218.2.7.2.58
Meter 3 Voltage LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter3-VRMSHigh 1.3.6.1.4.1.38218.2.7.2.59
Meter 3 Voltage HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter3-IRMSLow 1.3.6.1.4.1.38218.2.7.2.60
Meter 3 Amps LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter3-IRMSHigh 1.3.6.1.4.1.38218.2.7.2.61
Meter 3 Amps HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter3-KWSLow 1.3.6.1.4.1.38218.2.7.2.62
Meter 3 Kilowatts LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter3-KWSHigh 1.3.6.1.4.1.38218.2.7.2.63
Meter 3 Kilowatts HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter3-TempLow 1.3.6.1.4.1.38218.2.7.2.64
Meter 3 Temperature LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter3-TempHigh 1.3.6.1.4.1.38218.2.7.2.65
Meter 3 Temperature HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter3-PFLow 1.3.6.1.4.1.38218.2.7.2.66
Meter 3 Power Factor LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter3-PFHigh 1.3.6.1.4.1.38218.2.7.2.67
Meter 3 Power Factor HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter3-FreqLow 1.3.6.1.4.1.38218.2.7.2.68
Meter 3 Frequency LOW trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Clear-meter3-FreqHigh 1.3.6.1.4.1.38218.2.7.2.69
Meter 3 Frequency HIGH trap CLEAR notification
Status: current Access: read-write
NOTIFICATION-TYPE    

slave-Global-Table 1.3.6.1.4.1.38218.3.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Slave-Global-Entry

slave-Global-Entry 1.3.6.1.4.1.38218.3.1.1
Table of Trap notification destinations.
Status: current Access: not-accessible
OBJECT-TYPE    
  Slave-Global-Entry  

slave-Global-Index 1.3.6.1.4.1.38218.3.1.1.1
pdu index [0..Nopdus].
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..31  

slave-Global-Status 1.3.6.1.4.1.38218.3.1.1.2
Compatible - pdu ONLINE / OFFLINE or DISABLED status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER offline(0), online(1), disabled(2)  

slave-Global-Address 1.3.6.1.4.1.38218.3.1.1.3
Compatible - pdu MODBUS Address.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..32  

slave-Global-Nosockets 1.3.6.1.4.1.38218.3.1.1.4
Compatible - pdu Number of sockets.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..48  

slave-Global-meter1-VRMS 1.3.6.1.4.1.38218.3.1.1.5
Compatible - Meter 1 RMS Voltage (VAC) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-meter1-IRMS 1.3.6.1.4.1.38218.3.1.1.6
Compatible - Meter 1 RMS Current (A) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-meter1-KWH 1.3.6.1.4.1.38218.3.1.1.7
Compatible - Meter 1 Total energy consumption (kW/h) x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-meter1-KW 1.3.6.1.4.1.38218.3.1.1.8
Compatible - Meter 1 Kilowatts (kW) x1000.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-meter1-TPMU 1.3.6.1.4.1.38218.3.1.1.9
Compatible - Meter 1 Internal Temperature (C) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-meter1-PF 1.3.6.1.4.1.38218.3.1.1.10
Compatible - Meter 1 Power Factor x1000
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-environmental-Temp1 1.3.6.1.4.1.38218.3.1.1.11
Compatible - Environmental Temperature probe 1 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-environmental-Temp2 1.3.6.1.4.1.38218.3.1.1.12
Compatible - Environmental Temperature probe 2 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-environmental-Temp3 1.3.6.1.4.1.38218.3.1.1.13
Compatible - Environmental Temperature probe 3 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-environmental-Temp4 1.3.6.1.4.1.38218.3.1.1.14
Compatible - Environmental Temperature probe 4 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-environmental-Temp5 1.3.6.1.4.1.38218.3.1.1.15
Compatible - Environmental Temperature probe 5 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-environmental-Temp6 1.3.6.1.4.1.38218.3.1.1.16
Compatible - Environmental Temperature probe 6 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-environmental-Temp7 1.3.6.1.4.1.38218.3.1.1.17
Compatible - Environmental Temperature probe 7 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-environmental-Temp8 1.3.6.1.4.1.38218.3.1.1.18
Compatible - Environmental Temperature probe 8 (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-environmental-HumidityTemp 1.3.6.1.4.1.38218.3.1.1.19
Compatible - Environmental Humidity probe Temperature (C) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-environmental-Humidity 1.3.6.1.4.1.38218.3.1.1.20
Compatible - Environmental humidity probe (%) x100.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-environmental-Contact1 1.3.6.1.4.1.38218.3.1.1.21
Compatible - Environmental contact input 1 status. Set with any data to clear status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER open(0), closed(1), none(3)  

slave-Global-environmental-Contact2 1.3.6.1.4.1.38218.3.1.1.22
Compatible - Environmental contact input 2 status. Set with any data to clear status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER open(0), closed(1)  

slave-Global-environmental-Contact3 1.3.6.1.4.1.38218.3.1.1.23
Compatible - Environmental contact input 3 status. Set with any data to clear status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER open(0), closed(1)  

slave-Global-Security-Door 1.3.6.1.4.1.38218.3.1.1.24
Compatible - Environmental door contact status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER open(0), closed(1)  

slave-Global-Security-Lock 1.3.6.1.4.1.38218.3.1.1.25
Compatible - Environmental lock status. Set with any data to force unlock.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER locked(0), unlocked(1)  

slave-Global-sockets 1.3.6.1.4.1.38218.3.1.1.26
Compatible - socket status bits 1 to 32 Set or clear bit to control socket, Bit 0 = socket 1, Bit 31 = socket 32
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

slave-Global-socket1Amps 1.3.6.1.4.1.38218.3.1.1.27
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket2Amps 1.3.6.1.4.1.38218.3.1.1.28
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket3Amps 1.3.6.1.4.1.38218.3.1.1.29
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket4Amps 1.3.6.1.4.1.38218.3.1.1.30
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket5Amps 1.3.6.1.4.1.38218.3.1.1.31
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket6Amps 1.3.6.1.4.1.38218.3.1.1.32
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket7Amps 1.3.6.1.4.1.38218.3.1.1.33
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket8Amps 1.3.6.1.4.1.38218.3.1.1.34
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket9Amps 1.3.6.1.4.1.38218.3.1.1.35
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket10Amps 1.3.6.1.4.1.38218.3.1.1.36
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket11Amps 1.3.6.1.4.1.38218.3.1.1.37
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket12Amps 1.3.6.1.4.1.38218.3.1.1.38
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket13Amps 1.3.6.1.4.1.38218.3.1.1.39
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket14Amps 1.3.6.1.4.1.38218.3.1.1.40
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket15Amps 1.3.6.1.4.1.38218.3.1.1.41
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket16Amps 1.3.6.1.4.1.38218.3.1.1.42
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket17Amps 1.3.6.1.4.1.38218.3.1.1.43
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket18Amps 1.3.6.1.4.1.38218.3.1.1.44
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket19Amps 1.3.6.1.4.1.38218.3.1.1.45
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket20Amps 1.3.6.1.4.1.38218.3.1.1.46
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket21Amps 1.3.6.1.4.1.38218.3.1.1.47
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket22Amps 1.3.6.1.4.1.38218.3.1.1.48
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket23Amps 1.3.6.1.4.1.38218.3.1.1.49
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket24Amps 1.3.6.1.4.1.38218.3.1.1.50
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket25Amps 1.3.6.1.4.1.38218.3.1.1.51
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket26Amps 1.3.6.1.4.1.38218.3.1.1.52
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket27Amps 1.3.6.1.4.1.38218.3.1.1.53
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket28Amps 1.3.6.1.4.1.38218.3.1.1.54
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket29Amps 1.3.6.1.4.1.38218.3.1.1.55
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket30Amps 1.3.6.1.4.1.38218.3.1.1.56
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket31Amps 1.3.6.1.4.1.38218.3.1.1.57
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket32Amps 1.3.6.1.4.1.38218.3.1.1.58
Compatible - socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket1kWh 1.3.6.1.4.1.38218.3.1.1.59
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket2kWh 1.3.6.1.4.1.38218.3.1.1.60
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket3kWh 1.3.6.1.4.1.38218.3.1.1.61
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket4kWh 1.3.6.1.4.1.38218.3.1.1.62
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket5kWh 1.3.6.1.4.1.38218.3.1.1.63
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket6kWh 1.3.6.1.4.1.38218.3.1.1.64
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket7kWh 1.3.6.1.4.1.38218.3.1.1.65
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket8kWh 1.3.6.1.4.1.38218.3.1.1.66
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket9kWh 1.3.6.1.4.1.38218.3.1.1.67
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket10kWh 1.3.6.1.4.1.38218.3.1.1.68
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket11kWh 1.3.6.1.4.1.38218.3.1.1.69
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket12kWh 1.3.6.1.4.1.38218.3.1.1.70
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket13kWh 1.3.6.1.4.1.38218.3.1.1.71
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket14kWh 1.3.6.1.4.1.38218.3.1.1.72
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket15kWh 1.3.6.1.4.1.38218.3.1.1.73
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket16kWh 1.3.6.1.4.1.38218.3.1.1.74
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket17kWh 1.3.6.1.4.1.38218.3.1.1.75
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket18kWh 1.3.6.1.4.1.38218.3.1.1.76
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket19kWh 1.3.6.1.4.1.38218.3.1.1.77
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket20kWh 1.3.6.1.4.1.38218.3.1.1.78
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket21kWh 1.3.6.1.4.1.38218.3.1.1.79
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket22kWh 1.3.6.1.4.1.38218.3.1.1.80
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket23kWh 1.3.6.1.4.1.38218.3.1.1.81
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket24kWh 1.3.6.1.4.1.38218.3.1.1.82
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket25kWh 1.3.6.1.4.1.38218.3.1.1.83
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket26kWh 1.3.6.1.4.1.38218.3.1.1.84
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket27kWh 1.3.6.1.4.1.38218.3.1.1.85
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket28kWh 1.3.6.1.4.1.38218.3.1.1.86
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket29kWh 1.3.6.1.4.1.38218.3.1.1.87
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket30kWh 1.3.6.1.4.1.38218.3.1.1.88
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket31kWh 1.3.6.1.4.1.38218.3.1.1.89
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket32kWh 1.3.6.1.4.1.38218.3.1.1.90
Compatible - socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket33Amps 1.3.6.1.4.1.38218.3.1.1.91
socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket34Amps 1.3.6.1.4.1.38218.3.1.1.92
socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket35Amps 1.3.6.1.4.1.38218.3.1.1.93
socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket36Amps 1.3.6.1.4.1.38218.3.1.1.94
socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket37Amps 1.3.6.1.4.1.38218.3.1.1.95
socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket38Amps 1.3.6.1.4.1.38218.3.1.1.96
socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket39Amps 1.3.6.1.4.1.38218.3.1.1.97
socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket40Amps 1.3.6.1.4.1.38218.3.1.1.98
socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket41Amps 1.3.6.1.4.1.38218.3.1.1.99
socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket42Amps 1.3.6.1.4.1.38218.3.1.1.100
socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket43Amps 1.3.6.1.4.1.38218.3.1.1.101
socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket44Amps 1.3.6.1.4.1.38218.3.1.1.102
socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket45Amps 1.3.6.1.4.1.38218.3.1.1.103
socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket46Amps 1.3.6.1.4.1.38218.3.1.1.104
socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket47Amps 1.3.6.1.4.1.38218.3.1.1.105
socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket48Amps 1.3.6.1.4.1.38218.3.1.1.106
socket Amps value x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-socket33kWh 1.3.6.1.4.1.38218.3.1.1.107
socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket34kWh 1.3.6.1.4.1.38218.3.1.1.108
socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket35kWh 1.3.6.1.4.1.38218.3.1.1.109
socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket36kWh 1.3.6.1.4.1.38218.3.1.1.110
socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket37kWh 1.3.6.1.4.1.38218.3.1.1.111
socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket38kWh 1.3.6.1.4.1.38218.3.1.1.112
socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket39kWh 1.3.6.1.4.1.38218.3.1.1.113
socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket40kWh 1.3.6.1.4.1.38218.3.1.1.114
socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket41kWh 1.3.6.1.4.1.38218.3.1.1.115
socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket42kWh 1.3.6.1.4.1.38218.3.1.1.116
socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket43kWh 1.3.6.1.4.1.38218.3.1.1.117
socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket44kWh 1.3.6.1.4.1.38218.3.1.1.118
socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket45kWh 1.3.6.1.4.1.38218.3.1.1.119
socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket46kWh 1.3.6.1.4.1.38218.3.1.1.120
socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket47kWh 1.3.6.1.4.1.38218.3.1.1.121
socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-socket48kWh 1.3.6.1.4.1.38218.3.1.1.122
socket kWh value x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-sockets2 1.3.6.1.4.1.38218.3.1.1.123
socket status bits 33-48 Set or clear bit to control socket, Bit 0 = socket 33, Bit 15 = socket 48
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

slave-Global-meter1-Freq 1.3.6.1.4.1.38218.3.1.1.124
Meter 1 Frequency x10
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-meter2-VRMS 1.3.6.1.4.1.38218.3.1.1.125
Meter 2 RMS Voltage (VAC) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-meter2-IRMS 1.3.6.1.4.1.38218.3.1.1.126
Meter 2 RMS Current (A) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-meter2-KWH 1.3.6.1.4.1.38218.3.1.1.127
Meter 2 Total energy consumption (kW/h) x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-meter2-KW 1.3.6.1.4.1.38218.3.1.1.128
Meter 2 Kilowatts (kW) x1000.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-meter2-TPMU 1.3.6.1.4.1.38218.3.1.1.129
Meter 2 Internal Temperature (C) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-meter2-PF 1.3.6.1.4.1.38218.3.1.1.130
Meter 2 Power Factor x1000
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-meter2-Freq 1.3.6.1.4.1.38218.3.1.1.131
Meter 2 Frequency x10
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-meter3-VRMS 1.3.6.1.4.1.38218.3.1.1.132
Meter 3 RMS Voltage (VAC) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-meter3-IRMS 1.3.6.1.4.1.38218.3.1.1.133
Meter 3 RMS Current (A) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-meter3-KWH 1.3.6.1.4.1.38218.3.1.1.134
Meter 3 Total energy consumption (kW/h) x10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-meter3-KW 1.3.6.1.4.1.38218.3.1.1.135
Meter 3 Kilowatts (kW) x1000.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slave-Global-meter3-TPMU 1.3.6.1.4.1.38218.3.1.1.136
Meter 3 Internal Temperature (C) x10.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-meter3-PF 1.3.6.1.4.1.38218.3.1.1.137
Meter 3 Power Factor x1000
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

slave-Global-meter3-Freq 1.3.6.1.4.1.38218.3.1.1.138
Meter 3 Frequency x10
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER