OPTIX-SDH-PER-MIB

File: OPTIX-SDH-PER-MIB.mib (62768 bytes)

Imported modules

OPTIX-OID-MIB OPTIX-SDH-TC-MIB SNMPv2-CONF
SNMPv2-SMI SNMPv2-TC

Imported symbols

optixCommonSdh SdhPerformanceEventType OBJECT-GROUP
MODULE-COMPLIANCE mgmt Gauge32
OBJECT-TYPE MODULE-IDENTITY DateAndTime

Defined Types

RowStatus  
INTEGER active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6)    

Per15mCurrentDataEntry  
SEQUENCE    
  per15mCurrentDataBoardNo Gauge32
  per15mCurrentDataOpticalPort Gauge32
  per15mCurrentDataPathNumber Gauge32
  per15mCurrentDataEventID SdhPerformanceEventType
  per15mCurrentDataStartTime DateAndTime
  per15mCurrentDataValue Gauge32
  per15mCurrentDataReset INTEGER

Per15mHistoryDataEntry  
SEQUENCE    
  per15mHistoryDataBoardNo Gauge32
  per15mHistoryDataOpticalPort Gauge32
  per15mHistoryDataPathNumber Gauge32
  per15mHistoryDataEventID SdhPerformanceEventType
  per15mHistoryDataStartTime DateAndTime
  per15mHistoryDataValue Gauge32
  per15mHistoryDataReset INTEGER

Per24hHistoryDataEntry  
SEQUENCE    
  per24hHistoryDataBoardNo Gauge32
  per24hHistoryDataOpticalPort Gauge32
  per24hHistoryDataPathNumber Gauge32
  per24hHistoryDataEventID SdhPerformanceEventType
  per24hHistoryDataStartTime DateAndTime
  per24hHistoryDataValue Gauge32
  per24hHistoryDataReset INTEGER

Per24hCurrentDataEntry  
SEQUENCE    
  per24hCurrentDataBoardNo Gauge32
  per24hCurrentDataOpticalPort Gauge32
  per24hCurrentDataPathNumber Gauge32
  per24hCurrentDataEventID SdhPerformanceEventType
  per24hCurrentDataStartTime DateAndTime
  per24hCurrentDataValue Gauge32
  per24hCurrentDataReset INTEGER

Per15mThresholdEntry  
SEQUENCE    
  per15mThresholdBoardNo Gauge32
  per15mThresholdOpticalPort Gauge32
  per15mThresholdPathNumber Gauge32
  per15mThresholdEventID SdhPerformanceEventType
  per15mThresholdHighValue Gauge32
  per15mThresholdLowValue Gauge32
  per15mThresholdReset INTEGER

Per24hThresholdEntry  
SEQUENCE    
  per24hThresholdReset INTEGER
  per24hThresholdValue Gauge32
  per24hThresholdEventID SdhPerformanceEventType
  per24hThresholdPathNumber Gauge32
  per24hThresholdOpticalPort Gauge32
  per24hThresholdBoardNo Gauge32

Per15mMonitorStatusEntry  
SEQUENCE    
  per15mMonitorStatusBoardNo Gauge32
  per15mMonitorStatusOpticalPort Gauge32
  per15mMonitorStatusPathNumber Gauge32
  per15mMonitorStatusEventID SdhPerformanceEventType
  per15mMonitorStatus INTEGER

Per15mPauseStatusEntry  
SEQUENCE    
  per15mPauseStatusBoardNo Gauge32
  per15mPauseStatusOpticalPort Gauge32
  per15mPauseStatusPathNumber Gauge32
  per15mPauseStatusEventID SdhPerformanceEventType
  per15mPauseStatus INTEGER

Per15mThresholdStatusEntry  
SEQUENCE    
  per15mThresholdStatusBoardNo Gauge32
  per15mThresholdStatusOpticalPort Gauge32
  per15mThresholdStatusPathNumber Gauge32
  per15mThresholdStatusEventID SdhPerformanceEventType
  per15mThresholdStatus INTEGER

Per15mAutoReportStatusEntry  
SEQUENCE    
  per15mAutoReportStatusBoardNo Gauge32
  per15mAutoReportStatusOpticalPort Gauge32
  per15mAutoReportStatusPathNumber Gauge32
  per15mAutoReportStatusEventID SdhPerformanceEventType
  per15mAutoReportStatus INTEGER

Per24hMonitorStatusEntry  
SEQUENCE    
  per24hMonitorStatusBoardNo Gauge32
  per24hMonitorStatusOpticalPort Gauge32
  per24hMonitorStatusPathNumber Gauge32
  per24hMonitorStatusEventID SdhPerformanceEventType
  per24hMonitorStatus INTEGER

Per24hPauseStatusEntry  
SEQUENCE    
  per24hPauseStatusBoardNo Gauge32
  per24hPauseStatusOpticalPort Gauge32
  per24hPauseStatusPathNumber Gauge32
  per24hPauseStatusEventID SdhPerformanceEventType
  per24hPauseStatus INTEGER

Per24hThresholdStatusEntry  
SEQUENCE    
  per24hThresholdStatusBoardNo Gauge32
  per24hThresholdStatusOpticalPort Gauge32
  per24hThresholdStatusPathNumber Gauge32
  per24hThresholdStatusEventID SdhPerformanceEventType
  per24hThresholdStatus INTEGER

Per24hAutoReportStatusEntry  
SEQUENCE    
  per24hAutoReportStatusBoardNo Gauge32
  per24hAutoReportStatusOpticalPort Gauge32
  per24hAutoReportStatusPathNumber Gauge32
  per24hAutoReportStatusEventID SdhPerformanceEventType
  per24hAutoReportStatus INTEGER

Per15mThresholdCrossStatusEntry  
SEQUENCE    
  per15mThresholdCrossStatusBoardNo Gauge32
  per15mThresholdCrossStatusOpticalPort Gauge32
  per15mThresholdCrossStatusPathNumber Gauge32
  per15mThresholdCrossStatusEventID SdhPerformanceEventType
  per15mThresholdCrossStatus INTEGER

Per24hThresholdCrossStatusEntry  
SEQUENCE    
  per24hThresholdCrossStatus INTEGER
  per24hThresholdCrossStatusEventID SdhPerformanceEventType
  per24hThresholdCrossStatusPathNumber Gauge32
  per24hThresholdCrossStatusOpticalPort Gauge32
  per24hThresholdCrossStatusBoardNo Gauge32

PerUATEventEntry  
SEQUENCE    
  perUATBoardNo Gauge32
  perUATOpticalPort Gauge32
  perUATPathNumber Gauge32
  perUATEventID SdhPerformanceEventType
  perUATStartTime DateAndTime
  perUATEndTime DateAndTime

PerCSESEventEntry  
SEQUENCE    
  perCSESKeepTime Gauge32
  perCSESStartTime DateAndTime
  perCSESEventID SdhPerformanceEventType
  perCSESPathNumber Gauge32
  perCSESOpticalPort Gauge32
  perCSESBoardNo Gauge32

Defined Values

optixPerformance 1.3.6.1.4.1.2011.2.25.3.10.20
This module MIB describes the Optix Perfomance.
MODULE-IDENTITY    

perMonitorTime 1.3.6.1.4.1.2011.2.25.3.10.20.10
OBJECT IDENTIFIER    

per15mMonitorTime 1.3.6.1.4.1.2011.2.25.3.10.20.10.10
OBJECT IDENTIFIER    

per15mMonitorStartTime 1.3.6.1.4.1.2011.2.25.3.10.20.10.10.10
Start date and time of 15 minutes PM period.When system enter the per15mMonitorStartTime,15 minutes PM starts.the per15mMonitorStartTime should not ealier than current date and time, specially,when it is equal to 1990-00-00 00:00:00,15 minutes PM starts immediately.reset the per15mMonitorStartTime will terminate current 15 minutes PM period.When system enter the per15mMonitorEndTime, the per15mMonitorStartTime will be reset to zero.
Status: current Access: read-write
OBJECT-TYPE    
  DateAndTime  

per15mMonitorEndTime 1.3.6.1.4.1.2011.2.25.3.10.20.10.10.20
End date and time of 15 minutes PM period.you need set the per15mMonitorStartTime before set the per15mMonitorEndTime,and per15mMonitorStartTime should earlier than the per15mMonitorEndTime,specially,when the per15mMonitorEndTime is equal to 1990-00-00 00:00:00,15 minutes PM ends immediately. When system enter the per15mMonitorEndTime,the per15mMonitorEndTime will be reset to zero.
Status: current Access: read-write
OBJECT-TYPE    
  DateAndTime  

per24hMonitorTime 1.3.6.1.4.1.2011.2.25.3.10.20.10.20
OBJECT IDENTIFIER    

per24hMonitorStartTime 1.3.6.1.4.1.2011.2.25.3.10.20.10.20.10
Start date and time of one day PM period.When system enter the per24hMonitorStartTime,one day PM starts.the per24hMonitorStartTime should not ealier than current date and time, specially,when it is equal to 1990-00-00 00:00:00,one day PM starts immediately.reset the per24hMonitorStartTime will terminate current one day PM period.When system enter the per24hMonitorEndTime, the per24hMonitorStartTime will be reset to zero.
Status: current Access: read-write
OBJECT-TYPE    
  DateAndTime  

per24hMonitorEndTime 1.3.6.1.4.1.2011.2.25.3.10.20.10.20.20
End date and time of one day PM period.you need set the per24hMonitorStartTime before set the per24hMonitorEndTime,and per24hMonitorStartTime should earlier than the per24hMonitorEndTime,specially,when the per24hMonitorEndTime is equal to 1990-00-00 00:00:00,one day PM ends immediately. When system enter the per24hMonitorEndTime,the per24hMonitorEndTime will be reset to zero.
Status: current Access: read-write
OBJECT-TYPE    
  DateAndTime  

perMonitorData 1.3.6.1.4.1.2011.2.25.3.10.20.20
OBJECT IDENTIFIER    

per15mMonitoring 1.3.6.1.4.1.2011.2.25.3.10.20.20.10
OBJECT IDENTIFIER    

per15mCurrentDataTable 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10
15 minutes PM period current data table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Per15mCurrentDataEntry

per15mCurrentDataEntry 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1
15 minutes PM period current data entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Per15mCurrentDataEntry  

per15mCurrentDataBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.1
Card No.:between 1 and 20
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mCurrentDataOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.2
Optical port No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mCurrentDataPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.3
Path No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mCurrentDataEventID 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.4
Event ID:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  SdhPerformanceEventType  

per15mCurrentDataStartTime 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.5
start date and time: start date and time of current 15 minutes PM period.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

per15mCurrentDataValue 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.6
Current data value: value of current 15 minutes PM period register.the units of value vary as the PM event,fo example,the unit of RSUAS is 'second',while the unit of RSBBE is 'count'.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mCurrentDataReset 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.10.1.7
Current data reset: reset value of current 15 minutes PM period register to zero.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

per15mHistoryDataTable 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20
15 minutes PM period historic data table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Per15mHistoryDataEntry

per15mHistoryDataEntry 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1
15 minutes PM period historic data entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Per15mHistoryDataEntry  

per15mHistoryDataBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.1
Card No.:between 1 and 20
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mHistoryDataOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.2
Optical port No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mHistoryDataPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.3
Path No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mHistoryDataEventID 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.4
Event ID:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  SdhPerformanceEventType  

per15mHistoryDataStartTime 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.5
start date and time: start date and time of special 15 minutes PM period.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

per15mHistoryDataValue 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.6
Historic data value: value of special 15 minutes PM period register.the units of value vary as the PM event,fo example,the unit of RSUAS is 'second',while the unit of RSBBE is 'count'.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mHistoryDataReset 1.3.6.1.4.1.2011.2.25.3.10.20.20.10.20.1.7
Historic data reset: reset value of special 15 minutes PM period register to zero.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

per24hMonitoring 1.3.6.1.4.1.2011.2.25.3.10.20.20.20
OBJECT IDENTIFIER    

per24hHistoryDataTable 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20
one day PM period historic data table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Per24hHistoryDataEntry

per24hHistoryDataEntry 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1
one day PM period historic data entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Per24hHistoryDataEntry  

per24hHistoryDataBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.1
Card No.:between 1 and 20
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hHistoryDataOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.2
Optical port No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hHistoryDataPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.3
Path No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hHistoryDataEventID 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.4
Event ID:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  SdhPerformanceEventType  

per24hHistoryDataStartTime 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.5
start date and time: start date and time of special one day PM period.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

per24hHistoryDataValue 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.6
Historic data value: value of special one day PM period register.the units of value vary as the PM event,fo example,the unit of RSUAS is 'second',while the unit of RSBBE is 'count'.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hHistoryDataReset 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.20.1.7
Historic data reset: reset value of special one day PM period register to zero.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

per24hCurrentDataTable 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10
one day PM period current data table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Per24hCurrentDataEntry

per24hCurrentDataEntry 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1
one day PM period current data entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Per24hCurrentDataEntry  

per24hCurrentDataBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.1
Card No.:between 1 and 20
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hCurrentDataOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.2
Optical port No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hCurrentDataPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.3
Path No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hCurrentDataEventID 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.4
Event ID:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  SdhPerformanceEventType  

per24hCurrentDataStartTime 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.5
start date and time: start date and time of current one day PM period.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

per24hCurrentDataValue 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.6
Current data value: value of current one day PM period register.the units of value vary as the PM event,fo example,the unit of RSUAS is 'second',while the unit of RSBBE is 'count'.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hCurrentDataReset 1.3.6.1.4.1.2011.2.25.3.10.20.20.20.10.1.7
Current data reset: reset value of current one day PM period register to zero.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

perThreshold 1.3.6.1.4.1.2011.2.25.3.10.20.30
OBJECT IDENTIFIER    

per15mThreshold 1.3.6.1.4.1.2011.2.25.3.10.20.30.10
OBJECT IDENTIFIER    

per15mThresholdTable 1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10
15 minutes PM period threshold table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Per15mThresholdEntry

per15mThresholdEntry 1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1
15 minutes PM period threshold entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Per15mThresholdEntry  

per15mThresholdBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.1
Card No.:between 1 and 20
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mThresholdOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.2
Optical port No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mThresholdPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.3
Path No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mThresholdEventID 1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.4
Event ID:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  SdhPerformanceEventType  

per15mThresholdHighValue 1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.5
High threshold value: some parameters have two thresholds,such as RSBBE, while others have single threshold,such as RSSES.
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

per15mThresholdLowValue 1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.6
Low threshold value: specially,some parameters have single threshold, so their Low threshold should always be zero.
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

per15mThresholdReset 1.3.6.1.4.1.2011.2.25.3.10.20.30.10.10.1.7
Threshold reset: reset both high threshold and low threshold(if has).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

per24hThreshold 1.3.6.1.4.1.2011.2.25.3.10.20.30.20
OBJECT IDENTIFIER    

per24hThresholdTable 1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10
one day PM period threshold table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Per24hThresholdEntry

per24hThresholdEntry 1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1
one day PM period threshold entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Per24hThresholdEntry  

per24hThresholdReset 1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1.6
Threshold reset: reset threshold.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

per24hThresholdValue 1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1.5
Threshold value: all parameters have only one threshold value for one day PM period.
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

per24hThresholdEventID 1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1.4
Event ID:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  SdhPerformanceEventType  

per24hThresholdPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1.3
Path No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hThresholdOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1.2
Optical port No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hThresholdBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.30.20.10.1.1
Card No.:between 1 and 20
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

perStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40
OBJECT IDENTIFIER    

perStatusControl 1.3.6.1.4.1.2011.2.25.3.10.20.40.10
OBJECT IDENTIFIER    

per15mStatusControl 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10
OBJECT IDENTIFIER    

per15mMonitorStatusTable 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10
15 minutes PM period monitor status table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Per15mMonitorStatusEntry

per15mMonitorStatusEntry 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10.1
15 minutes PM period monitor status entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Per15mMonitorStatusEntry  

per15mMonitorStatusBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10.1.1
Card No.:between 1 and 20
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mMonitorStatusOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10.1.2
Optical port No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mMonitorStatusPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10.1.3
Path No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mMonitorStatusEventID 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10.1.4
Event ID:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  SdhPerformanceEventType  

per15mMonitorStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.10.1.5
Monitor status: when monitor status is disabled,current data register is reset to zero and will not increase any more until monitor status be enabled. The default monitor status is enable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

per15mPauseStatusTable 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20
15 minutes PM period pause status table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Per15mPauseStatusEntry

per15mPauseStatusEntry 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20.1
15 minutes PM period pause status entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Per15mPauseStatusEntry  

per15mPauseStatusBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20.1.1
Card No.:between 1 and 20
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mPauseStatusOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20.1.2
Optical port No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mPauseStatusPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20.1.3
Path No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mPauseStatusEventID 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20.1.4
Event ID:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  SdhPerformanceEventType  

per15mPauseStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.20.1.5
Pause status: when pause status is disabled,current data register will not increase (but will reset to zero)any more until pause status be enabled.The default monitor status is disable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

per15mThresholdStatusTable 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30
15 minutes PM period threshold status table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Per15mThresholdStatusEntry

per15mThresholdStatusEntry 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30.1
15 minutes PM period threshold status entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Per15mThresholdStatusEntry  

per15mThresholdStatusBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30.1.1
Card No.:between 1 and 20
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mThresholdStatusOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30.1.2
Optical port No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mThresholdStatusPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30.1.3
Path No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mThresholdStatusEventID 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30.1.4
Event ID:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  SdhPerformanceEventType  

per15mThresholdStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.30.1.5
Threshold status:when threshold status is disabled,no threshold crossing alert will be reported even though threshold is crossed.The default threshold status is enable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

per15mAutoReportStatusTable 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40
15 minutes PM period automatic report(REP) status table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Per15mAutoReportStatusEntry

per15mAutoReportStatusEntry 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40.1
15 minutes PM period automatic report(REP) status entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Per15mAutoReportStatusEntry  

per15mAutoReportStatusBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40.1.1
Card No.:between 1 and 20
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mAutoReportStatusOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40.1.2
Optical port No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mAutoReportStatusPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40.1.3
Path No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mAutoReportStatusEventID 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40.1.4
Event ID:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  SdhPerformanceEventType  

per15mAutoReportStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.10.40.1.5
Automatic report status: if automatic report status is enabled, when PM period expired, NE will report none-zero current data register value to user.The default automatic report status is enable .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

per24hStatusControl 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20
OBJECT IDENTIFIER    

per24hMonitorStatusTable 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10
one day PM period monitor status table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Per24hMonitorStatusEntry

per24hMonitorStatusEntry 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10.1
one day PM period monitor status entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Per24hMonitorStatusEntry  

per24hMonitorStatusBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10.1.1
Card No.:between 1 and 20
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hMonitorStatusOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10.1.2
Optical port No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hMonitorStatusPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10.1.3
Path No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hMonitorStatusEventID 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10.1.4
Event ID:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  SdhPerformanceEventType  

per24hMonitorStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.10.1.5
Monitor status: when monitor status is disabled,current data register is reset to zero and will not increase any more until monitor status be enabled.The default monitor status is enable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

per24hPauseStatusTable 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20
one day PM period pause status table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Per24hPauseStatusEntry

per24hPauseStatusEntry 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20.1
one day PM period pause status entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Per24hPauseStatusEntry  

per24hPauseStatusBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20.1.1
Card No.:between 1 and 20
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hPauseStatusOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20.1.2
Optical port No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hPauseStatusPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20.1.3
Path No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hPauseStatusEventID 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20.1.4
Event ID:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  SdhPerformanceEventType  

per24hPauseStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.20.1.5
Pause status: when pause status is disabled,current data register will not increase (but will reset to zero)any more until pause status be enabled.The default monitor status is disable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

per24hThresholdStatusTable 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30
one day PM period threshold status table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Per24hThresholdStatusEntry

per24hThresholdStatusEntry 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30.1
one day PM period threshold status entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Per24hThresholdStatusEntry  

per24hThresholdStatusBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30.1.1
Card No.:between 1 and 20
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hThresholdStatusOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30.1.2
Optical port No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hThresholdStatusPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30.1.3
Path No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hThresholdStatusEventID 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30.1.4
Event ID:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  SdhPerformanceEventType  

per24hThresholdStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.30.1.5
Threshold status:when threshold status is disabled,no threshold crossing alert will be reported even though threshold is crossed.The default threshold status is enable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

per24hAutoReportStatusTable 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40
one day PM period automatic report(REP) status table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Per24hAutoReportStatusEntry

per24hAutoReportStatusEntry 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40.1
one day PM period automatic report(REP) status entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Per24hAutoReportStatusEntry  

per24hAutoReportStatusBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40.1.1
Card No.:between 1 and 20
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hAutoReportStatusOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40.1.2
Optical port No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hAutoReportStatusPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40.1.3
Path No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hAutoReportStatusEventID 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40.1.4
Event ID:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  SdhPerformanceEventType  

per24hAutoReportStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.10.20.40.1.5
Automatic report status: if automatic report status is enabled, when PM period expired, NE will report none-zero current data register value to user.The default automatic report status is enable .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

perThresholdCrossStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.20
OBJECT IDENTIFIER    

per15mThresholdCrossStatusTable 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10
15 minutes PM period threshold crossing status table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Per15mThresholdCrossStatusEntry

per15mThresholdCrossStatusEntry 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10.1
15 minutes PM period threshold crossing status entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Per15mThresholdCrossStatusEntry  

per15mThresholdCrossStatusBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10.1.1
Card No.:between 1 and 20
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mThresholdCrossStatusOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10.1.2
Optical port No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mThresholdCrossStatusPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10.1.3
Path No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per15mThresholdCrossStatusEventID 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10.1.4
Event ID:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  SdhPerformanceEventType  

per15mThresholdCrossStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.10.1.5
Threshold crossing status:normal-threshold was not crossed,crossed -threshold was crossed.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(0), crossed(1)  

per24hThresholdCrossStatusTable 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20
one day PM period threshold crossing status table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Per24hThresholdCrossStatusEntry

per24hThresholdCrossStatusEntry 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20.1
one day PM period threshold crossing status entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Per24hThresholdCrossStatusEntry  

per24hThresholdCrossStatus 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20.1.5
Threshold crossing status:normal-threshold was not crossed,crossed -threshold was crossed.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(0), crossed(1)  

per24hThresholdCrossStatusEventID 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20.1.4
Event ID:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  SdhPerformanceEventType  

per24hThresholdCrossStatusPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20.1.3
Path No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hThresholdCrossStatusOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20.1.2
Optical port No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

per24hThresholdCrossStatusBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.40.20.20.1.1
Card No.:between 1 and 20
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

perEvents 1.3.6.1.4.1.2011.2.25.3.10.20.50
OBJECT IDENTIFIER    

perUATEvent 1.3.6.1.4.1.2011.2.25.3.10.20.50.10
OBJECT IDENTIFIER    

perUATEventTable 1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10
UAT event table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PerUATEventEntry

perUATEventEntry 1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1
UAT event entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  PerUATEventEntry  

perUATBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1.1
Card No.:between 1 and 20
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

perUATOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1.2
Optical port No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

perUATPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1.3
Path No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

perUATEventID 1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1.4
Event ID:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  SdhPerformanceEventType  

perUATStartTime 1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1.5
the date and time when enter UAT.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

perUATEndTime 1.3.6.1.4.1.2011.2.25.3.10.20.50.10.10.1.6
the date and time when exit UAT.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

perCSESEvent 1.3.6.1.4.1.2011.2.25.3.10.20.50.20
OBJECT IDENTIFIER    

perCSESEventTable 1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10
CSES event table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PerCSESEventEntry

perCSESEventEntry 1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1
CSES event entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  PerCSESEventEntry  

perCSESKeepTime 1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1.6
the count of CSES continues.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

perCSESStartTime 1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1.5
the date and time when enter CSES.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

perCSESEventID 1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1.4
Event ID:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  SdhPerformanceEventType  

perCSESPathNumber 1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1.3
Path No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

perCSESOpticalPort 1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1.2
Optical port No.:values depend on type of card
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

perCSESBoardNo 1.3.6.1.4.1.2011.2.25.3.10.20.50.20.10.1.1
Card No.:between 1 and 20
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

optixCommonSdhConformance 1.3.6.1.4.1.2011.2.25.3.10.20.90
OBJECT IDENTIFIER    

optixCommonSdhGroups 1.3.6.1.4.1.2011.2.25.3.10.20.90.1
OBJECT IDENTIFIER    

currentObjectGroup 1.3.6.1.4.1.2011.2.25.3.10.20.90.1.1
Enter the description of the created OBJECT-GROUP.
Status: current Access: read-only
OBJECT-GROUP    

optixCommonSdhCompliances 1.3.6.1.4.1.2011.2.25.3.10.20.90.2
OBJECT IDENTIFIER    

optixCommonSdhbasicCompliance 1.3.6.1.4.1.2011.2.25.3.10.20.90.2.1
Enter the description of the created MODULE-COMPLIANCE.
Status: current Access: read-only
MODULE-COMPLIANCE