OPCD-CONNECTORS-MIB-V2

File: OPCD-CONNECTORS-MIB-V2.mib (43191 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC OPCD-SUPPORT-MIB-V2

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
enterprises DisplayString opencode-systems

Defined Values

occonnectors 1.3.6.1.4.1.30374.16
OBJECT IDENTIFIER    

occonnectors-traps 1.3.6.1.4.1.30374.16.1
OBJECT IDENTIFIER    

definitions 1.3.6.1.4.1.30374.16.1.0
OBJECT IDENTIFIER    

vars 1.3.6.1.4.1.30374.16.1.1
OBJECT IDENTIFIER    

mcr-Host 1.3.6.1.4.1.30374.16.1.1.1
String containing hostname of fault node.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString Size(0..255)  

mcr-Severity 1.3.6.1.4.1.30374.16.1.1.2
Alarm severity.
Status: mandatory Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER critical(1), major(2), minor(3), normal(4), warning(5)  

mcr-Text 1.3.6.1.4.1.30374.16.1.1.3
String containing text of the alarm.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString Size(0..255)  

occonectors-LdapConnector 1.3.6.1.4.1.30374.16.1.0.2
LDAP Connector is down!
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-LdapConnector-Canceled 1.3.6.1.4.1.30374.16.1.0.3
LDAP Connector is down-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-MmlConnector 1.3.6.1.4.1.30374.16.1.0.4
MML Connector is down!
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-MmlConnector-Canceled 1.3.6.1.4.1.30374.16.1.0.5
MML Connector is down-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-UcpConnector 1.3.6.1.4.1.30374.16.1.0.6
UCP Connector is down!
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-UcpConnector-Canceled 1.3.6.1.4.1.30374.16.1.0.7
UCP Connector is down-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-UcipConnector 1.3.6.1.4.1.30374.16.1.0.8
UCIP Connector is down!
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-UcipConnector-Canceled 1.3.6.1.4.1.30374.16.1.0.9
UCIP Connector is down-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CaiConnector 1.3.6.1.4.1.30374.16.1.0.10
CAI Connector is down!
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CaiConnector-Canceled 1.3.6.1.4.1.30374.16.1.0.11
CAI Connector is down-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-SoapConnectorTimeout 1.3.6.1.4.1.30374.16.1.0.12
SOAP connector timeout.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-SoapConnectorTimeout-Canceled 1.3.6.1.4.1.30374.16.1.0.13
SOAP connector timeout-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-SoapConnectorLimit 1.3.6.1.4.1.30374.16.1.0.14
SOAP connector session limit is exceeded.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-SoapConnectorLimit-Canceled 1.3.6.1.4.1.30374.16.1.0.15
SOAP connector session limit is exceeded-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CorbaSib 1.3.6.1.4.1.30374.16.1.0.16
Cannot connect to CORBA-CIB server.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CorbaSib-Canceled 1.3.6.1.4.1.30374.16.1.0.17
Cannot connect to CORBA-CIB server-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CorbaSmaf 1.3.6.1.4.1.30374.16.1.0.18
Cannot connect to CORBA-SMAF server.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CorbaSmaf-Canceled 1.3.6.1.4.1.30374.16.1.0.19
Cannot connect to CORBA-SMAF server-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CorbaSih 1.3.6.1.4.1.30374.16.1.0.20
Cannot connect to CORBA-SIH server.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CorbaSih-Canceled 1.3.6.1.4.1.30374.16.1.0.21
Cannot connect to CORBA-SIH server-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-XMLConnectorTimeout 1.3.6.1.4.1.30374.16.1.0.22
XML connector timeout.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-XMLConnectorTimeout-Canceled 1.3.6.1.4.1.30374.16.1.0.23
XML connector timeout-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-XMLConnectorLimit 1.3.6.1.4.1.30374.16.1.0.24
XML connector session limit is exceeded.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-XMLConnectorLimit-Canceled 1.3.6.1.4.1.30374.16.1.0.25
XML connector session limit is exceeded-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-ORACLEConnector 1.3.6.1.4.1.30374.16.1.0.26
Oracle connector is down
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-ORACLEConnector-Canceled 1.3.6.1.4.1.30374.16.1.0.27
Oracle connector is down-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-MYSQL-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.28
No connection to MYSQL server 1.Check the connector's log file in order to find the reason for this alarm. 2.Check if there is ping to MySQL server. 3.Check MySQL logs for the possible reason for refusing connections from the connector
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-MYSQL-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.29
No connection to MYSQL server-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-SMPP-SERVER-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.30
No connection to SMPP server 1.Check the connector's log file in order to find the reason for this alarm. 2.Check if there is ping to SMPP server. 3.Check SMPP server logs for the possible reason for refusing connections from the connector
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-SMPP-SERVER-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.31
No connection to SMPP server-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-TELNET-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.32
No connection to TELNET server 1.Check the connector's log file in order to find the reason for this alarm. 2.Check if there is ping to TELNET server. 3.Check TELNET server logs for the possible reason for refusing connections from the connector
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-TELNET-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.33
No connection to TELNET server-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CORBA-SMAF-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.34
No connection to CORBA SMAF server 1.Check the connector's log file in order to find the reason for this alarm. 2.Check if there is ping to CORBA SMAF server. 3.Check CORBA SMAF server logs for the possible reason for refusing connections from the connector
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CORBA-SMAF-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.35
No connection to CORBA SMAF server - Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CORBA-SIH-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.36
No connection to CORBA SIH server 1.Check the connector's log file in order to find the reason for this alarm. 2.Check if there is ping to CORBA SIH server. 3.Check CORBA SIH server logs for the possible reason for refusing connections from the connector
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CORBA-SIH-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.37
No connection to CORBA SIH server-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CORBA-CX-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.38
No connection to CORBA CX server 1.Check the connector's log file in order to find the reason for this alarm. 2.Check if there is ping to CORBA CX server. 3.Check CORBA CX server logs for the possible reason for refusing connections from the connector
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CORBA-CX-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.39
No connection to CORBA CX server 1.Check the connector's log file in order to find the reason for this alarm. 2.Check if there is ping to CORBA CX server. 3.Check CORBA CX server logs for the possible reason for refusing connections from the connector
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CORBA-CIB-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.40
No connection to CORBA CIB server 1.Check the connector's log file in order to find the reason for this alarm. 2.Check if there is ping to CORBA CIB server. 3.Check CORBA CIB server logs for the possible reason for refusing connections from the connector
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CORBA-CIB-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.41
No connection to CORBA CIB server-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CORBA-ALCATEL-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.42
No connection to CORBA(Alcatel) server 1.Check the connector's log file in order to find the reason for this alarm. 2.Check if there is ping to CORBA(Alcatel) server. 3.Check CORBA(Alcatel) server logs for the possible reason for refusing connections from the connector
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CORBA-ALCATEL-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.43
No connection to CORBA(Alcatel) server -Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CAI-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.44
No connection to CAI server 1.Check the connector's log file in order to find the reason for this alarm. 2.Check if there is ping to CAI server. 3.Check CAI server logs for the possible reason for refusing connections from the connector
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CAI-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.45
No connection to CAI server 1.Check the connector's log file in order to find the reason for this alarm. 2.Check if there is ping to CAI server. 3.Check CAI server logs for the possible reason for refusing connections from the connector
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-BROADCAST-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.46
No connection to MYSQL server 1.Check the connector's log file in order to find the reason for this alarm. 2.Check if there is ping to MySQL server. 3.Check MySQL logs for the possible reason for refusing connections from the connector
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-BROADCAST-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.47
No connection to MYSQL server-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-LDAP-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.48
No connection to LDAP server 1.Check the connector's log file in order to find the reason for this alarm. 2.Check if there is ping to LDAP server. 3.Check LDAP logs for the possible reason for refusing connections from the connector
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-LDAP-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.49
No connection to LDAP server-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-DIAMETER-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.50
No connection to DIAMETER server 1.Check the connector's log file in order to find the reason for this alarm. 2.Check if there is ping to DIAMETER server. 3.Check DIAMTER server logs for the possible reason for refusing connections from the connector
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-DIAMETER-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.51
No connection to DIAMETER server-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-HTTPCLIENT-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.52
No connection to HTTP server 1.Check the connector's log file in order to find the reason for this alarm. 2.Check if there is ping to HTTP server. 3.Check HTTP server logs for the possible reason for refusing connections from the connector
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-HTTPCLIENT-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.53
No connection to HTTP server-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-BOOKMARK-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.54
No connection to MYSQL server 1.Check the connector's log file in order to find the reason for this alarm. 2.Check if there is ping to MySQL server. 3.Check MySQL logs for the possible reason for refusing connections from the connector
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-BOOKMARK-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.55
No connection to MYSQL server-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CORBA-INPAYMENT-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.56
No connection to IN(Payment) server 1.Check the connector's log file in order to find the reason for this alarm. 2.Check if there is ping to IN server. 3.Check IN logs for the possible reason for refusing connections from the connector
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CORBA-INPAYMENT-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.57
No connection to IN(Payment) server-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CORBA-PPSERVER-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.58
No connection to CORBA PP server 1.Check the connector's log file in order to find the reason for this alarm. 2.Check if there is ping to CORBA server. 3.Check CORBA logs for the possible reason for refusing connections from the connector
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-CORBA-PPSERVER-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.59
No connection to CORBA PP server-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-ecm-CONNECTOR-CRASHED 1.3.6.1.4.1.30374.16.1.0.60
Connector monitored by ECM crashed
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-ecm-CONNECTOR-CRASHED-Canceled 1.3.6.1.4.1.30374.16.1.0.61
Connector monitored by ECM crashed-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-ecm-CONNECTOR-DISABLED 1.3.6.1.4.1.30374.16.1.0.62
Connector disabled.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-ecm-CONNECTOR-DISABLED-Canceled 1.3.6.1.4.1.30374.16.1.0.63
Connector disabled-Canceled
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-MMLAUC-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.64
No connection to MML server
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-MMLAUC-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.65
No connection to MML server
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-ecm-CONNECTOR-PROBLEM 1.3.6.1.4.1.30374.16.1.0.66
The alarm is turned ON if any connector is not working properly: 1.all subconnectos or all IPC connections are not working 2.it exited unexpectedly 3.it is disabled by ECM because of too much retries to start
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

occonectors-ecm-CONNECTOR-PROBLEM-Canceled 1.3.6.1.4.1.30374.16.1.0.67
The alarm is turned ON if any connector is not working properly: 1.all subconnectos or all IPC connections are not working 2.it exited unexpectedly 3.it is disabled by ECM because of too much retries to start
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mcr-HTTP-SERVER-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.68
The alarm is turned ON if any connector is not working properly: 1.all subconnectos or all IPC connections are not working 2.it exited unexpectedly 3.it is disabled by ECM because of too much retries to start
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mcr-HTTP-SERVER-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.69
The alarm is turned ON if any connector is not working properly: 1.all subconnectos or all IPC connections are not working 2.it exited unexpectedly 3.it is disabled by ECM because of too much retries to start
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mcr-SPEECHLAB-TTS-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.70
The alarm is turned ON if any connector is not working properly: 1.all subconnectos or all IPC connections are not working 2.it exited unexpectedly 3.it is disabled by ECM because of too much retries to start
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mcr-SPEECHLAB-TTS-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.71
The alarm is turned ON if any connector is not working properly: 1.all subconnectos or all IPC connections are not working 2.it exited unexpectedly 3.it is disabled by ECM because of too much retries to start
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mcr-CIMD2-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.72
The alarm is turned ON if any connector is not working properly: 1.all subconnectos or all IPC connections are not working 2.it exited unexpectedly 3.it is disabled by ECM because of too much retries to start
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mcr-CIMD2-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.73
The alarm is turned ON if any connector is not working properly: 1.all subconnectos or all IPC connections are not working 2.it exited unexpectedly 3.it is disabled by ECM because of too much retries to start
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mcr-SOAP-CLIENT-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.74
The alarm is turned ON if any connector is not working properly: 1.all subconnectos or all IPC connections are not working 2.it exited unexpectedly 3.it is disabled by ECM because of too much retries to start
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mcr-SOAP-CLIENT-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.75
The alarm is turned ON if any connector is not working properly: 1.all subconnectos or all IPC connections are not working 2.it exited unexpectedly 3.it is disabled by ECM because of too much retries to start
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mcr-BLRATING-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.76
Alarm of type 'CONNECT' is ON when connector can't connect to MySQL server or when connected to it and lost connection later. This alarm is set OFF when connection is restored.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mcr-BLRATING-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.77
Alarm of type 'CONNECT' is ON when connector can't connect to MySQL server or when connected to it and lost connection later. This alarm is set OFF when connection is restored.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mcr-DMS-CLIENT-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.78
Alarm of type 'CONNECT' is ON when connector can't connect to HTTP server or when connected to it and lost connection later. This alarm is set OFF when connection is restored.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mcr-DMS-CLIENT-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.79
Alarm of type 'CONNECT' is ON when connector can't connect to HTTP server or when connected to it and lost connection later. This alarm is set OFF when connection is restored.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mcr-SMPP-EX-connector-CONNECT 1.3.6.1.4.1.30374.16.1.0.80
- All sessions for all configured clients are broken. - The connector exited unexpectedly. - The connector is disabled by ECM.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mcr-SMPP-EX-connector-CONNECT-Canceled 1.3.6.1.4.1.30374.16.1.0.81
- The connector has at least one connected session.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mcr-SMPP-EX-connector-CLIENT-SESS 1.3.6.1.4.1.30374.16.1.0.82
- One configured SMPP session is broken.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mcr-SMPP-EX-connector-CLIENT-SESS-Canceled 1.3.6.1.4.1.30374.16.1.0.83
- All configured SMPP sessions are connected.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mcr-SMPP-EX-connector-CLIENT-CONN 1.3.6.1.4.1.30374.16.1.0.84
- All sessions for one configured client are broken.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mcr-SMPP-EX-connector-CLIENT-CONN-Canceled 1.3.6.1.4.1.30374.16.1.0.85
- At least one session is connected for this client.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mcr-SMPP-EX-connector-SERVER-CONN 1.3.6.1.4.1.30374.16.1.0.86
- Server cannot be started.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mcr-SMPP-EX-connector-SERVER-CONN-Canceled 1.3.6.1.4.1.30374.16.1.0.87
- Server is started.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE