OacSysCpuUsedCoresEntry |
|
SEQUENCE |
|
|
|
|
oacSysCpuUsedIndex |
Unsigned32 |
|
|
oacSysCpuUsedCoreType |
OASysCoreType |
|
|
oacSysCpuUsedValue |
Unsigned32 |
|
|
oacSysCpuUsedOneMinuteValue |
Unsigned32 |
|
OacExpIMSysHwComponentsEntry |
|
SEQUENCE |
|
|
|
|
oacExpIMSysHwcIndex |
Unsigned32 |
|
|
oacExpIMSysHwcClass |
OASysHwcClass |
|
|
oacExpIMSysHwcType |
OASysHwcType |
|
|
oacExpIMSysHwcDescription |
DisplayString |
|
|
oacExpIMSysHwcSerialNumber |
DisplayString |
|
|
oacExpIMSysHwcManufacturer |
DisplayString |
|
|
oacExpIMSysHwcManufacturedDate |
DisplayString |
|
|
oacExpIMSysHwcProductName |
DisplayString |
|
oacSysIMSysMainBoard |
1.3.6.1.4.1.13191.10.3.3.2.1 |
OBJECT IDENTIFIER |
|
|
|
oacSysIMSysMainIdentifier |
1.3.6.1.4.1.13191.10.3.3.2.1.1 |
The vendor's authoritative identification of
the main board. This value is allocated within
the SMI enterprise subtree |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OBJECT IDENTIFIER |
|
|
oacSysIMSysMainManufacturedIdentity |
1.3.6.1.4.1.13191.10.3.3.2.1.2 |
Unique ID string self to each equipment.
By default, it is retrieved from the
manufacturer of the equipment. Can also be
configure by CLI ( see command 'snmp chassis-id')
for customer purposes |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
oacSysIMSysMainManufacturedDate |
1.3.6.1.4.1.13191.10.3.3.2.1.3 |
the date of the manufacturing of
the equipment |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
oacSysIMSysMainCPU |
1.3.6.1.4.1.13191.10.3.3.2.1.4 |
Description of the main CPU used
on the main board |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
oacSysIMSysMainBSPVersion |
1.3.6.1.4.1.13191.10.3.3.2.1.5 |
the current BSP version supported
on the equipment |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
oacSysIMSysMainBootVersion |
1.3.6.1.4.1.13191.10.3.3.2.1.6 |
the current boot version supported
on the equipment |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
oacSysIMSysMainBootDateCreation |
1.3.6.1.4.1.13191.10.3.3.2.1.7 |
the date the current boot version
has been generated |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
oacSysCpuUsedCoresEntry |
1.3.6.1.4.1.13191.10.3.3.1.2.3.1 |
Table entry for a hardware Core |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
OacSysCpuUsedCoresEntry |
|
|
oacExpIMSysHwComponentsEntry |
1.3.6.1.4.1.13191.10.3.3.2.2.2.1 |
Table entry for a hardware component |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
OacExpIMSysHwComponentsEntry |
|
|