OMNI-gx2drr2x-MIB

File: OMNI-gx2drr2x-MIB.mib (72731 bytes)

Imported modules

RFC-1212 RFC1213-MIB RFC-1215
GX2HFC-MIB NLSBBN-TRAPS-MIB

Imported symbols

OBJECT-TYPE Counter DisplayString
TRAP-TYPE gx2Drr2x trapIdentifier
trapNetworkElemModelNumber trapNetworkElemSerialNum trapPerceivedSeverity
trapNetworkElemOperState trapNetworkElemAlarmStatus trapNetworkElemAdminState
trapNetworkElemAvailStatus trapText trapNETrapLastTrapTimeStamp
trapChangedObjectId trapChangedValueInteger trapChangedValueDisplayString

Defined Types

Float  
Counter    

Gx2drr2xAnalogEntry  
SEQUENCE    
  gx2drr2xAnalogTableIndex INTEGER
  drr2xlabelRFAAttenuation DisplayString Size(0..80)
  drr2xuomRFAAttenuation DisplayString Size(0..80)
  drr2xmajorHighRFAAttenuation Float
  drr2xmajorLowRFAAttenuation Float
  drr2xminorHighRFAAttenuation Float
  drr2xminorLowRFAAttenuation Float
  drr2xcurrentValueRFAAttenuation Float
  drr2xstateFlagRFAAttenuation INTEGER
  drr2xminValueRFAAttenuation Float
  drr2xmaxValueRFAAttenuation Float
  drr2xalarmStateRFAAttenuation INTEGER
  drr2xlabelRFBAttenuation DisplayString Size(0..80)
  drr2xuomRFBAttenuation DisplayString Size(0..80)
  drr2xmajorHighRFBAttenuation Float
  drr2xmajorLowRFBAttenuation Float
  drr2xminorHighRFBAttenuation Float
  drr2xminorLowRFBAttenuation Float
  drr2xcurrentValueRFBAttenuation Float
  drr2xstateFlagRFBAttenuation INTEGER
  drr2xminValueRFBAttenuation Float
  drr2xmaxValueRFBAttenuation Float
  drr2xalarmStateRFBAttenuation INTEGER
  drr2xlabelTrippointLevel DisplayString Size(0..80)
  drr2xuomTrippointLevel DisplayString Size(0..80)
  drr2xmajorHighTrippointLevel Float
  drr2xmajorLowTrippointLevel Float
  drr2xminorHighTrippointLevel Float
  drr2xminorLowTrippointLevel Float
  drr2xcurrentValueTrippointLevel Float
  drr2xstateFlagTrippointLevel INTEGER
  drr2xminValueTrippointLevel Float
  drr2xmaxValueTrippointLevel Float
  drr2xalarmStateTrippointLevel INTEGER
  drr2xlabelOptCurrent DisplayString Size(0..80)
  drr2xuomOptCurrent DisplayString Size(0..80)
  drr2xmajorHighOptCurrent Float
  drr2xmajorLowOptCurrent Float
  drr2xminorHighOptCurrent Float
  drr2xminorLowOptCurrent Float
  drr2xcurrentValueOptCurrent Float
  drr2xstateFlagOptCurrent INTEGER
  drr2xminValueOptCurrent Float
  drr2xmaxValueOptCurrent Float
  drr2xalarmStateOptCurrent INTEGER
  drr2xlabel12VCurrent DisplayString Size(0..80)
  drr2xuom12VCurrent DisplayString Size(0..80)
  drr2xmajorHigh12VCurrent Float
  drr2xmajorLow12VCurrent Float
  drr2xminorHigh12VCurrent Float
  drr2xminorLow12VCurrent Float
  drr2xcurrentValue12VCurrent Float
  drr2xstateFlag12VCurrent INTEGER
  drr2xminValue12VCurrent Float
  drr2xmaxValue12VCurrent Float
  drr2xalarmState12VCurrent INTEGER
  drr2xlabelModTemp DisplayString Size(0..80)
  drr2xuomModTemp DisplayString Size(0..80)
  drr2xmajorHighModTemp Float
  drr2xmajorLowModTemp Float
  drr2xminorHighModTemp Float
  drr2xminorLowModTemp Float
  drr2xcurrentValueModTemp Float
  drr2xstateFlagModTemp INTEGER
  drr2xminValueModTemp Float
  drr2xmaxValueModTemp Float
  drr2xalarmStateModTemp INTEGER
  drr2xlabelFanCurrent DisplayString Size(0..80)
  drr2xuomFanCurrent DisplayString Size(0..80)
  drr2xmajorHighFanCurrent Float
  drr2xmajorLowFanCurrent Float
  drr2xminorHighFanCurrent Float
  drr2xminorLowFanCurrent Float
  drr2xcurrentValueFanCurrent Float
  drr2xstateFlagFanCurrent INTEGER
  drr2xminValueFanCurrent Float
  drr2xmaxValueFanCurrent Float
  drr2xalarmStateFanCurrent INTEGER

Gx2drr2xDigitalEntry  
SEQUENCE    
  gx2drr2xDigitalTableIndex INTEGER
  drr2xlabelTrippointMode DisplayString Size(0..80)
  drr2xenumTrippointMode DisplayString Size(0..80)
  drr2xvalueTrippointMode INTEGER
  drr2xstateflagTrippointMode INTEGER
  drr2xlabelFactoryDefaultReset DisplayString Size(0..80)
  drr2xenumFactoryDefaultReset DisplayString Size(0..80)
  drr2xvalueFactoryDefaultReset INTEGER
  drr2xstateflagFactoryDefaultReset INTEGER

Gx2drr2xStatusEntry  
SEQUENCE    
  gx2drr2xStatusTableIndex INTEGER
  drr2xlabelBoot DisplayString Size(0..80)
  drr2xvalueBoot INTEGER
  drr2xstateflagBoot INTEGER
  drr2xlabelFlash DisplayString Size(0..80)
  drr2xvalueFlash INTEGER
  drr2xstateflagFlash INTEGER
  drr2xlabelFactoryDataCRC DisplayString Size(0..80)
  drr2xvalueFactoryDataCRC INTEGER
  drr2xstateflagFactoryDataCRC INTEGER
  drr2xlabelAlarmDataCrc DisplayString Size(0..80)
  drr2xvalueAlarmDataCrc INTEGER
  drr2xstateflagAlarmDataCrc INTEGER
  drr2xlabelCalibrationDataCrc DisplayString Size(0..80)
  drr2xvalueCalibrationDataCrc INTEGER
  drr2xstateflagCalibrationDataCrc INTEGER
  drr2xlabelHardwareStatus DisplayString Size(0..80)
  drr2xvalueHardwareStatus INTEGER
  drr2xstateflagHardwareStatus INTEGER
  drr2xlabelOpticTripPointStatus DisplayString Size(0..80)
  drr2xvalueOpticTripPointStatus INTEGER
  drr2xstateflagOpticTripPointStatus INTEGER
  drr2xlabelLinkStatus DisplayString Size(0..80)
  drr2xvalueLinkStatus INTEGER
  drr2xstateflagLinkStatus INTEGER

Gx2drr2xFactoryEntry  
SEQUENCE    
  gx2drr2xFactoryTableIndex INTEGER
  drr2xbootControlByte INTEGER
  drr2xbootStatusByte INTEGER
  drr2xbank1CRC INTEGER
  drr2xbank2CRC INTEGER
  drr2xprgEEPROMByte INTEGER
  drr2xfactoryCRC INTEGER
  drr2xcalculateCRC INTEGER
  drr2xhourMeter INTEGER
  drr2xflashPrgCntA INTEGER
  drr2xflashPrgCntB INTEGER
  drr2xflashBankARev DisplayString Size(0..80)
  drr2xflashBankBRev DisplayString Size(0..80)
  drr2xSubAgentRev DisplayString Size(0..80)

Defined Values

gx2drr2xDescriptor 1.3.6.1.4.1.1166.6.1.2.21.1
OBJECT IDENTIFIER    

gx2drr2xAnalogTable 1.3.6.1.4.1.1166.6.1.2.21.2
This table contains gx2drr2x specific analog parameters with nominal,limits and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2drr2xAnalogEntry

gx2drr2xAnalogEntry 1.3.6.1.4.1.1166.6.1.2.21.2.1
This list contains the analog parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2drr2xAnalogEntry  

gx2drr2xDigitalTable 1.3.6.1.4.1.1166.6.1.2.21.3
This table contains gx2drr2x specific digital parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2drr2xDigitalEntry

gx2drr2xDigitalEntry 1.3.6.1.4.1.1166.6.1.2.21.3.2
This list contains individual digital parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2drr2xDigitalEntry  

gx2drr2xStatusTable 1.3.6.1.4.1.1166.6.1.2.21.4
This table contains gx2drr2x specific status parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2drr2xStatusEntry

gx2drr2xStatusEntry 1.3.6.1.4.1.1166.6.1.2.21.4.3
This list contains Status parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2drr2xStatusEntry  

gx2drr2xFactoryTable 1.3.6.1.4.1.1166.6.1.2.21.5
This table contains gx2drr2x specific factory setting parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2drr2xFactoryEntry

gx2drr2xFactoryEntry 1.3.6.1.4.1.1166.6.1.2.21.5.4
This list contains Factory setting parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2drr2xFactoryEntry  

gx2drr2xAnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.21.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

drr2xlabelRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.2
The value of this object provides the label of the RF Channel A Attenuation Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xuomRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.3
The value of this object provides the Unit of Measure of the RF Channel A Attenuation Analog parameter. The unit is in dB
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xmajorHighRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.4
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr2xmajorLowRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.5
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr2xminorHighRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.6
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr2xminorLowRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.7
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr2xcurrentValueRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.8
The value of this object provides the Current value of the RF Channel A Attenuation Analog parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

drr2xstateFlagRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.9
The value of this object provides the state of the RF Channel A Attenuation Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr2xminValueRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.10
The value of this object provides the minimum value the RF Channel A Attenuation Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xmaxValueRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.11
The value of this object provides the maximum value the RF Channel A Attenuation Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xalarmStateRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.12
The value of this object provides the curent alarm state of the RF Channel A Attenuation Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

drr2xlabelRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.13
The value of this object provides the label of the RF Channel B Attenuation Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xuomRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.14
The value of this object provides the Unit of Measure of the RF Channel B Attenuation Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xmajorHighRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.15
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr2xmajorLowRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.16
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr2xminorHighRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.17
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr2xminorLowRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.18
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr2xcurrentValueRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.19
The value of this object provides the Current value of the RF Channel B Attenuation Analog parameter. The unit is dB
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

drr2xstateFlagRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.20
The value of this object provides the state of the RF Channel B Attenuation Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr2xminValueRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.21
The value of this object provides the minimum value the RF Channel B Attenuation Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xmaxValueRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.22
The value of this object provides the maximum value the RF Channel B Attenuation Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xalarmStateRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.21.2.1.23
The value of this object provides the curent alarm state of the RF Channel B Attenuation Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

drr2xlabelTrippointLevel 1.3.6.1.4.1.1166.6.1.2.21.2.1.24
The value of this object provides the label of the trip point level Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xuomTrippointLevel 1.3.6.1.4.1.1166.6.1.2.21.2.1.25
The value of this object provides the Unit of Measure of the trip point level Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xmajorHighTrippointLevel 1.3.6.1.4.1.1166.6.1.2.21.2.1.26
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr2xmajorLowTrippointLevel 1.3.6.1.4.1.1166.6.1.2.21.2.1.27
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr2xminorHighTrippointLevel 1.3.6.1.4.1.1166.6.1.2.21.2.1.28
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr2xminorLowTrippointLevel 1.3.6.1.4.1.1166.6.1.2.21.2.1.29
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr2xcurrentValueTrippointLevel 1.3.6.1.4.1.1166.6.1.2.21.2.1.30
The value of this object provides the Current value of the trip point level Analog parameter. The trip point level set the custumer preferred optical input level. This parameter combined with trippoint mode decides the trippoint alarm and RF channel output impedance. when optical power level is lower than trip point level(Set by this parameter) 1) When trip point mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance will be changed to high impedance. 2) When trippoint mode is ALARM_ONLY, trippoint alarm will be generated but RF output inpedance remains to be low impedance. This trip point level value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

drr2xstateFlagTrippointLevel 1.3.6.1.4.1.1166.6.1.2.21.2.1.31
The value of this object provides the state of the trip point level Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr2xminValueTrippointLevel 1.3.6.1.4.1.1166.6.1.2.21.2.1.32
The value of this object provides the minimum value the trip point level Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xmaxValueTrippointLevel 1.3.6.1.4.1.1166.6.1.2.21.2.1.33
The value of this object provides the maximum value the trip point level Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xalarmStateTrippointLevel 1.3.6.1.4.1.1166.6.1.2.21.2.1.34
The value of this object provides the curent alarm state of the trip point level Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

drr2xlabelOptCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.35
The value of this object provides the label of the Optical Power Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xuomOptCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.36
The value of this object provides the Unit of Measure of the Optical Power Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xmajorHighOptCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.37
The value of this object provides the Major High alarm value of the Optical Power Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xmajorLowOptCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.38
The value of this object provides the Major Low alarm value of the Optical Power Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xminorHighOptCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.39
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr2xminorLowOptCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.40
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr2xcurrentValueOptCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.41
The value of this object provides the Current value of the Optical Power Current Analog parameter. The input optical power in lower than min value, drr2xcurrentValueOptCurrent will report -99dBm The input optical power in higher than this value, drr2xcurrentValueOptCurrent will report 99dBm
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xstateFlagOptCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.42
The value of this object provides the state of the Optical Power Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr2xminValueOptCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.43
This is recommended min range for display gauge
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xmaxValueOptCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.44
This is recommended max range for display gauge
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xalarmStateOptCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.45
The value of this object provides the curent alarm state of the Optical Power Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

drr2xlabel12VCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.46
The value of this object provides the label of the 12v power supply Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xuom12VCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.47
The value of this object provides the Unit of Measure of the 12v power supply Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xmajorHigh12VCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.48
The value of this object provides the Major High alarm value of the 12v power supply Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xmajorLow12VCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.49
The value of this object provides the Major Low alarm value of the 12v power supply Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xminorHigh12VCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.50
The value of this object provides the Minor High alarm value of the 12v power supply Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xminorLow12VCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.51
The value of this object provides the Minor Low alarm value of the 12v power supply Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xcurrentValue12VCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.52
The value of this object provides the Current value of the 12v power supply Current parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xstateFlag12VCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.53
The value of this object provides the state of the 12v power supply Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr2xminValue12VCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.54
The value of this object provides the minimum value the 12v power supply Current Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xmaxValue12VCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.55
The value of this object provides the maximum value the 12v power supply Current Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xalarmState12VCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.56
The value of this object provides the curent alarm state of the 12v power supply Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

drr2xlabelModTemp 1.3.6.1.4.1.1166.6.1.2.21.2.1.57
The value of this object provides the label of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xuomModTemp 1.3.6.1.4.1.1166.6.1.2.21.2.1.58
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xmajorHighModTemp 1.3.6.1.4.1.1166.6.1.2.21.2.1.59
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xmajorLowModTemp 1.3.6.1.4.1.1166.6.1.2.21.2.1.60
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xminorHighModTemp 1.3.6.1.4.1.1166.6.1.2.21.2.1.61
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xminorLowModTemp 1.3.6.1.4.1.1166.6.1.2.21.2.1.62
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xcurrentValueModTemp 1.3.6.1.4.1.1166.6.1.2.21.2.1.63
The value of this object provides the Current value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xstateFlagModTemp 1.3.6.1.4.1.1166.6.1.2.21.2.1.64
The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr2xminValueModTemp 1.3.6.1.4.1.1166.6.1.2.21.2.1.65
The value of this object provides the minimum value the Module Temperature Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xmaxValueModTemp 1.3.6.1.4.1.1166.6.1.2.21.2.1.66
The value of this object provides the maximum value the Module Temperature Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xalarmStateModTemp 1.3.6.1.4.1.1166.6.1.2.21.2.1.67
The value of this object provides the curent alarm state of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

drr2xlabelFanCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.68
The value of this object provides the label of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xuomFanCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.69
The value of this object provides the Unit of Measure of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xmajorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.70
The value of this object provides the Major High alarm value of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xmajorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.71
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xminorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.72
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr2xminorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.73
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr2xcurrentValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.74
The value of this object provides the Current value of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xstateFlagFanCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.75
The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr2xminValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.76
The value of this object provides the minimum value the Fan Current Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xmaxValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.77
The value of this object provides the maximum value the Fan Current Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr2xalarmStateFanCurrent 1.3.6.1.4.1.1166.6.1.2.21.2.1.78
The value of this object provides the curent alarm state of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gx2drr2xDigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.21.3.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

drr2xlabelTrippointMode 1.3.6.1.4.1.1166.6.1.2.21.3.2.2
The value of this object provides the label of the Trip point mode Digital parameter. The trip point mode defines the RF switch action based on the optical power input to the DRR
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xenumTrippointMode 1.3.6.1.4.1.1166.6.1.2.21.3.2.3
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xvalueTrippointMode 1.3.6.1.4.1.1166.6.1.2.21.3.2.4
The value of this object is the current value of trip point mode. There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch. If module input optical power is higher than the preset trippoint value, no operational difference for these three modes. If module input optical power is less than the preset trippoint value, 1) When trippoint mode is OFF, no trippoint alarm will be generated and RF output impedance will stay normal as low. 2) When tripoint mode is ALARM_ONLY, trip_point alarm will be generated when the input optical power lower than the preset trippoint level but RF output impedance will stay normal as low. 3) When trippoint mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance will switch to abnorml
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), alarmOnly(2), alarm-and-Switch(3)  

drr2xstateflagTrippointMode 1.3.6.1.4.1.1166.6.1.2.21.3.2.5
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), readOnly(2), updateable(3)  

drr2xlabelFactoryDefaultReset 1.3.6.1.4.1.1166.6.1.2.21.3.2.6
The value of this object provides the label of the Factory Default Reset Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xenumFactoryDefaultReset 1.3.6.1.4.1.1166.6.1.2.21.3.2.7
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xvalueFactoryDefaultReset 1.3.6.1.4.1.1166.6.1.2.21.3.2.8
The read of this value will return a invalid value. The read will not reflect the actual setting value for this parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

drr2xstateflagFactoryDefaultReset 1.3.6.1.4.1.1166.6.1.2.21.3.2.9
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2drr2xStatusTableIndex 1.3.6.1.4.1.1166.6.1.2.21.4.3.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

drr2xlabelBoot 1.3.6.1.4.1.1166.6.1.2.21.4.3.2
The value of this object provides the label of the Boot Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xvalueBoot 1.3.6.1.4.1.1166.6.1.2.21.4.3.3
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

drr2xstateflagBoot 1.3.6.1.4.1.1166.6.1.2.21.4.3.4
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr2xlabelFlash 1.3.6.1.4.1.1166.6.1.2.21.4.3.5
The value of this object provides the label of the Flash Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xvalueFlash 1.3.6.1.4.1.1166.6.1.2.21.4.3.6
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

drr2xstateflagFlash 1.3.6.1.4.1.1166.6.1.2.21.4.3.7
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr2xlabelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.21.4.3.8
The value of this object provides the label of the Factory Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xvalueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.21.4.3.9
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

drr2xstateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.21.4.3.10
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr2xlabelAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.21.4.3.11
The value of this object provides the label of the Alarm Data Crc parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xvalueAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.21.4.3.12
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

drr2xstateflagAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.21.4.3.13
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr2xlabelCalibrationDataCrc 1.3.6.1.4.1.1166.6.1.2.21.4.3.14
The value of this object provides the label of the Calibration Data Crc parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xvalueCalibrationDataCrc 1.3.6.1.4.1.1166.6.1.2.21.4.3.15
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

drr2xstateflagCalibrationDataCrc 1.3.6.1.4.1.1166.6.1.2.21.4.3.16
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr2xlabelHardwareStatus 1.3.6.1.4.1.1166.6.1.2.21.4.3.17
The value of this object provides the label of the Module Hardware Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xvalueHardwareStatus 1.3.6.1.4.1.1166.6.1.2.21.4.3.18
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

drr2xstateflagHardwareStatus 1.3.6.1.4.1.1166.6.1.2.21.4.3.19
The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr2xlabelOpticTripPointStatus 1.3.6.1.4.1.1166.6.1.2.21.4.3.20
The value of this object provides the label of the Optical Trip Point Status parameter.It indicates whether the optical power is above(0) or below(1) trip point value
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xvalueOpticTripPointStatus 1.3.6.1.4.1.1166.6.1.2.21.4.3.21
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

drr2xstateflagOpticTripPointStatus 1.3.6.1.4.1.1166.6.1.2.21.4.3.22
The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr2xlabelLinkStatus 1.3.6.1.4.1.1166.6.1.2.21.4.3.23
The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xvalueLinkStatus 1.3.6.1.4.1.1166.6.1.2.21.4.3.24
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

drr2xstateflagLinkStatus 1.3.6.1.4.1.1166.6.1.2.21.4.3.25
The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2drr2xFactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.21.5.4.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

drr2xbootControlByte 1.3.6.1.4.1.1166.6.1.2.21.5.4.2
The value of this object indicates which bank the firmware is currently being boot from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

drr2xbootStatusByte 1.3.6.1.4.1.1166.6.1.2.21.5.4.3
This object indicates the status of the last boot
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

drr2xbank1CRC 1.3.6.1.4.1.1166.6.1.2.21.5.4.4
This object provides the CRC code of bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

drr2xbank2CRC 1.3.6.1.4.1.1166.6.1.2.21.5.4.5
This object provides the CRC code of bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

drr2xprgEEPROMByte 1.3.6.1.4.1.1166.6.1.2.21.5.4.6
This object indicates if the EEPROM has been programmed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

drr2xfactoryCRC 1.3.6.1.4.1.1166.6.1.2.21.5.4.7
This object provides the CRC code for the Factory data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

drr2xcalculateCRC 1.3.6.1.4.1.1166.6.1.2.21.5.4.8
This object indicates which of the Emnums will have the CRC calculated (1-factory, 2-alarm, 3-calibration).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER factory(1), alarm(2), calibration(3)  

drr2xhourMeter 1.3.6.1.4.1.1166.6.1.2.21.5.4.9
This object provides the hour meter reading of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

drr2xflashPrgCntA 1.3.6.1.4.1.1166.6.1.2.21.5.4.10
This object provides the number of times Bank 0 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

drr2xflashPrgCntB 1.3.6.1.4.1.1166.6.1.2.21.5.4.11
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

drr2xflashBankARev 1.3.6.1.4.1.1166.6.1.2.21.5.4.12
This object provides the revision of flash bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xflashBankBRev 1.3.6.1.4.1.1166.6.1.2.21.5.4.13
This object provides the revision of flash bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr2xSubAgentRev 1.3.6.1.4.1.1166.6.1.2.21.5.4.14
This object provides the subagent revision of receiver module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

trapdrrConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapdrrConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapdrr12VCurrentAlarm 3
This trap is issued when the 12V power supply Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapdrrModuleTempAlarm 4
This trap is issued when the Internal Module Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapdrrFanCurrentAlarm 5
This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapdrrFlashAlarm 6
This trap is issued when the detects an error during Flash memory operations.
TRAP-TYPE    

trapdrrBankBootAlarm 7
This trap is issued when the module detects an error while booting from bank 0 or bank 1.
TRAP-TYPE    

trapdrrAlarmDataCRCAlarm 8
This trap is issued when the Alarm Data CRC is incorrect.
TRAP-TYPE    

trapdrrHardwareErrAlarm 9
This trap is issued when hardware is abnormal.
TRAP-TYPE    

trapdrrOpticalSignalAlarm 10
This trap is issued when the optical signal is beyond the preset range.
TRAP-TYPE    

trapdrrFactoryDataCRCAlarm 11
This trap is issued when the Factory Data CRC is incorrect.
TRAP-TYPE    

trapdrrResetFactoryDefaultAlarm 12
This trap is issued when the Factory Default Reset occurs.
TRAP-TYPE    

trapdrrTripPointAlarm 13
This trap is issued when the Input optical power is lower than the custumer set trip point and trippoint mode as ALARM_ONLY or SWITCH & ALARM.
TRAP-TYPE    

trapdrrLinkAlarm 14
This trap is issued when receiver is out of SYN with transmitter
TRAP-TYPE    

trapdrrCalibrationDataCRCAlarm 15
This trap is issued when the Calibration Data CRC is incorrect
TRAP-TYPE