NORTEL-NMI-FAULT-NOTI-MIB
File:
NORTEL-NMI-FAULT-NOTI-MIB.mib (17133 bytes)
Imported modules
Imported symbols
Defined Values
nortelNMIfaultNotiMIB |
1.3.6.1.4.1.562.29.1.6.4 |
This module contains the fault management related
notifications for the Nortel NMI. |
MODULE-IDENTITY |
|
|
|
nortelNMIfaultNotiPrefix |
1.3.6.1.4.1.562.29.1.6.4.0 |
This OID represents the prefix branch for all Nortel NMI
fault Notifications.
The last but one sub identifier in the OID of
any Notification must have the value zero to facilitate
v2<-->v1 conversion. |
Status: current |
Access: read-write |
OBJECT-IDENTITY |
|
|
|
nortelNMIfaultNotiVarbinds |
1.3.6.1.4.1.562.29.1.6.4.1 |
This OID represents the branch which contains varbinds to
fault management related notifications. |
Status: current |
Access: read-write |
OBJECT-IDENTITY |
|
|
|
nortelNMInotifyAlarmComponentId |
1.3.6.1.4.1.562.29.1.6.4.1.1 |
This variable represents the Distinguished Name (DN)
(refer X.720) of the component object against which the
particular alarm is raised. The entire component hierarchy
should be presented in the category-value information
model to unambiguosly identify the specific component
object instance. Here category refers to the type of the
component and value refers to the
instance identifier, both are represented as strings.
The format of the string is
NEtype=NEname;component class=component instance Id;....
The root component is always the NE and the NE is identified
via its type as the category and the value as the NE name.
The managed element class for the NE is implicitly assumed.
The NE type is based on NortelNMIneType textual convention.
With NE as the root, the entire containment with the list of
Relative Distinguished Names (RDNs) is presented upto the
point where the alarming component is clearly identified.
Semicolon is the delimiter between a 'category=value' pair.
The string can only contain alphanumeric characters and
underscores. No commas, spaces, slashes, hyphens, or
dollar signs is allowed. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
nortelNMInotifyAlarmCategory |
1.3.6.1.4.1.562.29.1.6.4.1.2 |
This variable presents the problem category of the alarm
as per the definition of the textual convention
NortelNMIalarmProblemCategory from NORTEL-NMI-TC-MIB. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
NortelNMIalarmProblemCategory |
|
|
nortelNMInotifyAlarmNotificationID |
1.3.6.1.4.1.562.29.1.6.4.1.3 |
This variable is the notification identifier of the alarm
that must be unique across all notifications of the particular NE
in context through the time that correlation is significant. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..1073741824 |
|
nortelNMInotifyAlarmTimeStamp |
1.3.6.1.4.1.562.29.1.6.4.1.5 |
This variable presents the relative timestamp of
occurrence of the alarm.
NortelNMItimeStampDef textual convention is defined at the
NORTEL-NMI-TC-MIB. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
NortelNMItimeStampDef |
|
|
nortelNMInotifyAlarmSpecificProblem |
1.3.6.1.4.1.562.29.1.6.4.1.7 |
This variable provides the specific problem data
(ITU-T X.733) to further qualify the probable cause
of the particular alarm. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(1..255) |
|
nortelNMInotifyAlarmCorrelationIdList |
1.3.6.1.4.1.562.29.1.6.4.1.8 |
This variable provides the list of Notification Ids of
previously reported alarms that this alarm correlates to.
This correlation refers to implicitly clearing
the previously raised alarms and overriding them with
this alarm report. The format of this string is
'notificationID1;notificationID2......',
with a list of integer notification ID values corresponding to
the correlated alarms with ';' as the delimiter between any
two Notification Identifiers. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
nortelNMIneOSIstateChangeNotification |
1.3.6.1.4.1.562.29.1.6.4.0.101 |
This notification indicates that one of the NE OSI states
has been changed. The modified value of the specific state
would be included as the varbind in the actual
Notification PDU. We currently support changes to
admin state, operational state and unknown status. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
nortelNMIalarmClearNotification |
1.3.6.1.4.1.562.29.1.6.4.0.201 |
This notification indicates that one or more previously
reported alarms have been cleared and the previously reported
alarms are identified via the correlation id list field.
The varbinds include alarm context via the ComponentId field
and other additional useful information. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
nortelNMIwarningAlarmNotification |
1.3.6.1.4.1.562.29.1.6.4.0.202 |
This notification indicates that an alarm of 'Warning' severity
has been raised on a NE.
The varbinds include alarm context via the ComponentId field
and other additional useful information on the alarm condition. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
nortelNMIminorAlarmNotification |
1.3.6.1.4.1.562.29.1.6.4.0.203 |
This notification indicates that an alarm of 'Minor' severity
has been raised on a NE.
The varbinds include alarm context via the ComponentId field
and other additional useful information on the alarm condition. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
nortelNMImajorAlarmNotification |
1.3.6.1.4.1.562.29.1.6.4.0.204 |
This notification indicates that an alarm of 'Major' severity
has been raised on a NE.
The varbinds include alarm context via the ComponentId field
and other additional useful information on the alarm condition. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
nortelNMIcriticalAlarmNotification |
1.3.6.1.4.1.562.29.1.6.4.0.205 |
This notification indicates that an alarm of 'Critical' severity
has been raised on a NE.
The varbinds include alarm context via the ComponentId field
and other additional useful information on the alarm condition. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|