NMS-CARD-SYS-MIB

File: NMS-CARD-SYS-MIB.mib (6147 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
NMS-SMI RFC1213-MIB NMS-CHASSIS

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
TEXTUAL-CONVENTION TimeStamp MODULE-COMPLIANCE
OBJECT-GROUP NOTIFICATION-GROUP nmsMgmt
nmslocal DisplayString nmscardIndex
nmscardDescr nmscardType

Defined Types

CardSystemSetEntry  
SEQUENCE    
  cardSysIndex INTEGER
  cardSysDescr DisplayString
  cardSysType INTEGER
  cardCPUUtilThreshold INTEGER
  cardMemUtilThreshold INTEGER
  cardCPUTempThreshold INTEGER
  cardCPUTempCurr INTEGER

Defined Values

cardSys 1.3.6.1.4.1.3320.9.181
OBJECT IDENTIFIER    

cardSystemSetTable 1.3.6.1.4.1.3320.9.181.1
A list of cards system related set value entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CardSystemSetEntry

cardSystemSetEntry 1.3.6.1.4.1.3320.9.181.1.1
A collection of cards to be reset.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CardSystemSetEntry  

cardSysIndex 1.3.6.1.4.1.3320.9.181.1.1.1
Index into cardTable (not physical chassis slot number), the same with the nmscardIndex of nmscardTable in NMS-CHASSIS-MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cardSysDescr 1.3.6.1.4.1.3320.9.181.1.1.2
the same with the nmscardDescr of nmscardTable in NMS-CHASSIS-MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cardSysType 1.3.6.1.4.1.3320.9.181.1.1.3
the same with the nmscardType of nmscardTable in NMS-CHASSIS-MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cardCPUUtilThreshold 1.3.6.1.4.1.3320.9.181.1.1.4
Card CPU utilization upper limit value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cardMemUtilThreshold 1.3.6.1.4.1.3320.9.181.1.1.5
Card memory utilization upper limit value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cardCPUTempThreshold 1.3.6.1.4.1.3320.9.181.1.1.6
Card CPU temperature upper limit value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cardCPUTempCurr 1.3.6.1.4.1.3320.9.181.1.1.7
Card CPU current temperature.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cardElementStatus 1.3.6.1.4.1.3320.9.181.2
Card element status, only use for variable binding in card system notifications.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER normal(1), warning(2)  

cardElementType 1.3.6.1.4.1.3320.9.181.3
Card element status, only use for variable binding in card system notifications.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER cpu(1), memory(2), cpu-temperature(3)  

cardSysNotifications 1.3.6.1.4.1.3320.9.181.4
OBJECT IDENTIFIER    

cardSysNotification 1.3.6.1.4.1.3320.9.181.4.1
The agent generates this notification when certain card element value exceeds upper limit defined above.
Status: current Access: not-accessible
NOTIFICATION-TYPE