MY-SYSTEM-MIB

File: MY-SYSTEM-MIB.mib (7932 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
MY-SMI

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Integer32 Counter32 TruthValue
DisplayString RowStatus MODULE-COMPLIANCE
OBJECT-GROUP NOTIFICATION-GROUP myMgmt

Defined Values

mySystemMIB 1.3.6.1.4.1.4881.1.1.10.2.1
This module defines my system mibs.
MODULE-IDENTITY    

mySystemMIBObjects 1.3.6.1.4.1.4881.1.1.10.2.1.1
OBJECT IDENTIFIER    

mySystemHwVersion 1.3.6.1.4.1.4881.1.1.10.2.1.1.1
Return the string of the Revision number of hardware resides on the FastSwitch.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

mySystemSwVersion 1.3.6.1.4.1.4881.1.1.10.2.1.1.2
Return the string of the Revision number of software resides on the FastSwitch.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

mySystemBootVersion 1.3.6.1.4.1.4881.1.1.10.2.1.1.3
Return the string of the Revision number of BOOT software resides on the FastSwitch.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

mySystemSysCtrlVersion 1.3.6.1.4.1.4881.1.1.10.2.1.1.4
Return the string of the Revision number of CTRL software resides on the FastSwitch.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

mySystemParametersSave 1.3.6.1.4.1.4881.1.1.10.2.1.1.5
Save all parameters changed in configuration by setting this object to any value but 0, set its value to 0 will cause no action of agent, otherwise all changes of prarameters will be saved for retrive when system is reset, if parameter is changed but not saved all changes will come to their original value when system down and up again, when query always return value 0.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

mySystemOutBandRate 1.3.6.1.4.1.4881.1.1.10.2.1.1.6
Determine the console(OutBand) baud rate : 9600 - 1,19200 - 2, 38300 - 3, 57600 - 4
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER baud9600(1), baud19200(2), baud38400(3), baud57600(4)  

mySystemReset 1.3.6.1.4.1.4881.1.1.10.2.1.1.7
This Object allow perform soft reset of system by setting its value to none zero. if a soft resetis performed, after this having completed a warm start trap will send to declare the state and when queried will always return 0.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

mySwitchLayer 1.3.6.1.4.1.4881.1.1.10.2.1.1.8
Which layer's device the switch in system
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER layer2(1), layer3(2)  

mySystemHwPower 1.3.6.1.4.1.4881.1.1.10.2.1.1.9
The state of power.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER rpsNoLink(1), rpsLinkAndNoPower(2), rpsLinkAndReadyForPower(3), rpsLinkAndPower(4)  

mySystemHwFan 1.3.6.1.4.1.4881.1.1.10.2.1.1.10
The state of fan.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER work(1), stop(2)  

mySystemOutBandTimeout 1.3.6.1.4.1.4881.1.1.10.2.1.1.11
The timeout of console.0 indicate that timeout function is disabled.
Status: obsolete Access: read-write
OBJECT-TYPE    
  Integer32 0..3600  

mySystemTelnetTimeout 1.3.6.1.4.1.4881.1.1.10.2.1.1.12
The timeout of telnet.0 indicate that timeout function is disabled.
Status: obsolete Access: read-write
OBJECT-TYPE    
  Integer32 0..3600  

mySystemMIBTraps 1.3.6.1.4.1.4881.1.1.10.2.1.2
OBJECT IDENTIFIER    

mySystemHardChangeDesc 1.3.6.1.4.1.4881.1.1.10.2.1.2.1
The description of hard change
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

mySystemHardChangeDetected 1.3.6.1.4.1.4881.1.1.10.2.1.2.2
System hardware has changed include number of devices or number of modules or the place or type of the module is change.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mySystemPowerStateChange 1.3.6.1.4.1.4881.1.1.10.2.1.2.3
while the state of power changed, then this trap will be sent.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mySystemFanStateChange 1.3.6.1.4.1.4881.1.1.10.2.1.2.4
while the state of fan changed, then this trap will be sent.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mySystemMIBConformance 1.3.6.1.4.1.4881.1.1.10.2.1.3
OBJECT IDENTIFIER    

mySystemMIBCompliances 1.3.6.1.4.1.4881.1.1.10.2.1.3.1
OBJECT IDENTIFIER    

mySystemMIBGroups 1.3.6.1.4.1.4881.1.1.10.2.1.3.2
OBJECT IDENTIFIER    

mySystemMIBCompliance 1.3.6.1.4.1.4881.1.1.10.2.1.3.1.1
The compliance statement for entities which implement the My System MIB
Status: current Access: accessible-for-notify
MODULE-COMPLIANCE    

mySystemMIBGroup 1.3.6.1.4.1.4881.1.1.10.2.1.3.2.1
A collection of objects providing system information and opertion to a My agent.
Status: current Access: accessible-for-notify
OBJECT-GROUP