MY-SYSTEM-MIB
File:
MY-SYSTEM-MIB.mib (7932 bytes)
Imported modules
Imported symbols
Defined Values
mySystemMIB |
1.3.6.1.4.1.4881.1.1.10.2.1 |
This module defines my system mibs. |
MODULE-IDENTITY |
|
|
|
mySystemHwVersion |
1.3.6.1.4.1.4881.1.1.10.2.1.1.1 |
Return the string of the Revision number of hardware resides
on the FastSwitch. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(1..32) |
|
mySystemSwVersion |
1.3.6.1.4.1.4881.1.1.10.2.1.1.2 |
Return the string of the Revision number of software resides
on the FastSwitch. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(1..32) |
|
mySystemBootVersion |
1.3.6.1.4.1.4881.1.1.10.2.1.1.3 |
Return the string of the Revision number of BOOT software resides
on the FastSwitch. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(1..32) |
|
mySystemSysCtrlVersion |
1.3.6.1.4.1.4881.1.1.10.2.1.1.4 |
Return the string of the Revision number of CTRL software resides
on the FastSwitch. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(1..32) |
|
mySystemOutBandRate |
1.3.6.1.4.1.4881.1.1.10.2.1.1.6 |
Determine the console(OutBand) baud rate :
9600 - 1,19200 - 2, 38300 - 3, 57600 - 4 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
baud9600(1), baud19200(2), baud38400(3), baud57600(4) |
|
mySystemReset |
1.3.6.1.4.1.4881.1.1.10.2.1.1.7 |
This Object allow perform soft reset of system by setting its
value to none zero. if a soft resetis performed, after this
having completed a warm start trap will send to declare the state
and when queried will always return 0. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
mySwitchLayer |
1.3.6.1.4.1.4881.1.1.10.2.1.1.8 |
Which layer's device the switch in system |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
layer2(1), layer3(2) |
|
mySystemHwPower |
1.3.6.1.4.1.4881.1.1.10.2.1.1.9 |
The state of power. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
rpsNoLink(1), rpsLinkAndNoPower(2), rpsLinkAndReadyForPower(3), rpsLinkAndPower(4) |
|
mySystemHwFan |
1.3.6.1.4.1.4881.1.1.10.2.1.1.10 |
The state of fan. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
work(1), stop(2) |
|
mySystemOutBandTimeout |
1.3.6.1.4.1.4881.1.1.10.2.1.1.11 |
The timeout of console.0 indicate that timeout function is disabled. |
Status: obsolete |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..3600 |
|
mySystemTelnetTimeout |
1.3.6.1.4.1.4881.1.1.10.2.1.1.12 |
The timeout of telnet.0 indicate that timeout function is disabled. |
Status: obsolete |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..3600 |
|
mySystemHardChangeDetected |
1.3.6.1.4.1.4881.1.1.10.2.1.2.2 |
System hardware has changed include number of devices or number of modules
or the place or type of the module is change. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
mySystemPowerStateChange |
1.3.6.1.4.1.4881.1.1.10.2.1.2.3 |
while the state of power changed, then this trap will be sent. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
mySystemFanStateChange |
1.3.6.1.4.1.4881.1.1.10.2.1.2.4 |
while the state of fan changed, then this trap will be sent. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
mySystemMIBCompliance |
1.3.6.1.4.1.4881.1.1.10.2.1.3.1.1 |
The compliance statement for entities which implement
the My System MIB |
Status: current |
Access: accessible-for-notify |
MODULE-COMPLIANCE |
|
|
|
mySystemMIBGroup |
1.3.6.1.4.1.4881.1.1.10.2.1.3.2.1 |
A collection of objects providing system information and
opertion to a My agent. |
Status: current |
Access: accessible-for-notify |
OBJECT-GROUP |
|
|
|