MX25-OPT-MIB

File: MX25-OPT-MIB.mib (53475 bytes)

Imported modules

RFC1155-SMI RFC-1212

Imported symbols

Counter enterprises OBJECT-TYPE

Defined Types

DisplayString  
OCTET STRING    

Cdx6500PPCTMX25PortEntry  
SEQUENCE    
  cdx6500mx25pCfgPortNum INTEGER
  cdx6500mx25pSubType INTEGER

Cdx6500PPCTMX25MPortEntry  
SEQUENCE    
  cdx6500mx25mpCfgPortNum INTEGER
  cdx6500mx25mpSubType INTEGER
  cdx6500mx25mpClockSource INTEGER
  cdx6500mx25mpClockSpeed INTEGER
  cdx6500mx25mpStationCnt INTEGER
  cdx6500mx25mpPollTimer INTEGER
  cdx6500mx25mpPollPeriod INTEGER
  cdx6500mx25mpTries INTEGER
  cdx6500mx25mpRestartTimer INTEGER
  cdx6500mx25mpResetTimer INTEGER
  cdx6500mx25mpCallTimer INTEGER
  cdx6500mx25mpClearTimer INTEGER
  cdx6500mx25mpPortControl DisplayString
  cdx6500mx25mpTXEncoding INTEGER
  cdx6500mx25mpElectricalInterfaceType INTEGER
  cdx6500mx25mpV24ElectricalInterfaceOption INTEGER
  cdx6500mx25mpHighSpeedElectricalInterfaceOption INTEGER

Cdx6500PPCTMX25SPortEntry  
SEQUENCE    
  cdx6500mx25spCfgPortNum INTEGER
  cdx6500mx25spSubType INTEGER
  cdx6500mx25spClockSource INTEGER
  cdx6500mx25spClockSpeed INTEGER
  cdx6500mx25spStationAddress DisplayString
  cdx6500mx25spPVCChannels INTEGER
  cdx6500mx25spStartingPVC INTEGER
  cdx6500mx25spSVCChannels INTEGER
  cdx6500mx25spStartingSVC INTEGER
  cdx6500mx25spPollTimer INTEGER
  cdx6500mx25spTries INTEGER
  cdx6500mx25spFrameWinSize INTEGER
  cdx6500mx25spPacketWinSize INTEGER
  cdx6500mx25spRestartTimer INTEGER
  cdx6500mx25spResetTimer INTEGER
  cdx6500mx25spCallTimer INTEGER
  cdx6500mx25spClearTimer INTEGER
  cdx6500mx25spMX25Options DisplayString
  cdx6500mx25spRCDestination DisplayString
  cdx6500mx25spCUG DisplayString
  cdx6500mx25spBillingRecords INTEGER
  cdx6500mx25spPortControl DisplayString
  cdx6500mx25spTXEncoding INTEGER
  cdx6500mx25spUpperQueue INTEGER
  cdx6500mx25spLowerQueue INTEGER
  cdx6500mx25spElectricalInterfaceType INTEGER
  cdx6500mx25spV24ElectricalInterfaceOption INTEGER
  cdx6500mx25spHighSpeedElectricalInterfaceOption INTEGER

Cdx6500PPSTMX25PortEntry  
SEQUENCE    
  cdx6500mx25pStatsPortNum INTEGER
  cdx6500mx25pPortStatus DisplayString
  cdx6500mx25pPortSpeed INTEGER
  cdx6500mx25pCharInTotal Counter
  cdx6500mx25pCharOutTotal Counter
  cdx6500mx25pCharsInPerSec INTEGER
  cdx6500mx25pCharsOutPerSec INTEGER
  cdx6500mx25pFrameInTotal Counter
  cdx6500mx25pFrameOutTotal Counter
  cdx6500mx25pFramesInPerSec INTEGER
  cdx6500mx25pFramesOutPerSec INTEGER

Cdx6500SPCTMX25StationEntry  
SEQUENCE    
  cdx6500mx25sCfgPortNum INTEGER
  cdx6500mx25sCfgStationNum INTEGER
  cdx6500mx25sStationAddress DisplayString
  cdx6500mx25sPVCChannels INTEGER
  cdx6500mx25sStartingPVC INTEGER
  cdx6500mx25sSVCChannels INTEGER
  cdx6500mx25sStartingSVC INTEGER
  cdx6500mx25sFrameWinSize INTEGER
  cdx6500mx25sPacketWinSize INTEGER
  cdx6500mx25sMX25Options DisplayString
  cdx6500mx25sRCDestination DisplayString
  cdx6500mx25sCUG DisplayString
  cdx6500mx25sBillingRecords INTEGER
  cdx6500mx25sUpperQueue INTEGER
  cdx6500mx25sLowerQueue INTEGER

Cdx6500SPSTMX25StationEntry  
SEQUENCE    
  cdx6500mx25sStatsPortNum INTEGER
  cdx6500mx25sStatsStationNum INTEGER
  cdx6500mx25sStatsStnAddr DisplayString
  cdx6500mx25sCharInTotal Counter
  cdx6500mx25sCharOutTotal Counter
  cdx6500mx25sCharsInPerSec INTEGER
  cdx6500mx25sCharsOutPerSec INTEGER
  cdx6500mx25sFrameInTotal Counter
  cdx6500mx25sFrameOutTotal Counter
  cdx6500mx25sFramesInPerSec INTEGER
  cdx6500mx25sFramesOutPerSec INTEGER
  cdx6500mx25sCallCount INTEGER

Cdx6500ContMX25StationEntry  
SEQUENCE    
  cdx6500mx25sContPortNum INTEGER
  cdx6500mx25sContStationNum INTEGER
  cdx6500mx25sContBootStation INTEGER
  cdx6500mx25sContDisableStation INTEGER
  cdx6500mx25sContEnableStation INTEGER
  cdx6500mx25sContBusyOutStation INTEGER
  cdx6500mx25sContResetStnStats INTEGER

Defined Values

codex 1.3.6.1.4.1.449
OBJECT IDENTIFIER    

cdxProductSpecific 1.3.6.1.4.1.449.2
OBJECT IDENTIFIER    

cdx6500 1.3.6.1.4.1.449.2.1
OBJECT IDENTIFIER    

cdx6500Configuration 1.3.6.1.4.1.449.2.1.2
OBJECT IDENTIFIER    

cdx6500CfgProtocolGroup 1.3.6.1.4.1.449.2.1.2.1
OBJECT IDENTIFIER    

cdx6500PCTPortProtocolGroup 1.3.6.1.4.1.449.2.1.2.1.1
OBJECT IDENTIFIER    

cdx6500PCTStationProtocolGroup 1.3.6.1.4.1.449.2.1.2.1.3
OBJECT IDENTIFIER    

cdx6500Statistics 1.3.6.1.4.1.449.2.1.3
OBJECT IDENTIFIER    

cdx6500StatProtocolGroup 1.3.6.1.4.1.449.2.1.3.1
OBJECT IDENTIFIER    

cdx6500PSTPortProtocolGroup 1.3.6.1.4.1.449.2.1.3.1.1
OBJECT IDENTIFIER    

cdx6500PSTStationProtocolGroup 1.3.6.1.4.1.449.2.1.3.1.3
OBJECT IDENTIFIER    

cdx6500Controls 1.3.6.1.4.1.449.2.1.4
OBJECT IDENTIFIER    

cdx6500ContMX25 1.3.6.1.4.1.449.2.1.4.6
OBJECT IDENTIFIER    

cdx6500PPCTMX25PortTables 1.3.6.1.4.1.449.2.1.2.1.1.4
OBJECT IDENTIFIER    

cdx6500PPCTMX25PortTable 1.3.6.1.4.1.449.2.1.2.1.1.4.1
All of the common configuration parameters relevant to the MX.25 port table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PPCTMX25PortEntry

cdx6500PPCTMX25PortEntry 1.3.6.1.4.1.449.2.1.2.1.1.4.1.1
A row of MX.25 Port configuration parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500PPCTMX25PortEntry  

cdx6500mx25pCfgPortNum 1.3.6.1.4.1.449.2.1.2.1.1.4.1.1.1
MX25 Port Number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500mx25pSubType 1.3.6.1.4.1.449.2.1.2.1.1.4.1.1.2
This is the mode in which this MX25 port will run. newvalMaster : same functionality as 'master', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER master(0), slave(1), newvalMaster(50)  

cdx6500PPCTMX25MPortTable 1.3.6.1.4.1.449.2.1.2.1.1.4.2
All of the configuration parameters relevant to the MX.25 Master port table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PPCTMX25MPortEntry

cdx6500PPCTMX25MPortEntry 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1
A row of MX.25 Master Port configuration parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500PPCTMX25MPortEntry  

cdx6500mx25mpCfgPortNum 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.1
MX25 Port Number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500mx25mpSubType 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.2
This is the mode in which this MX25 port will run. newvalMaster : same functionality as 'master', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER master(0), newvalMaster(50)  

cdx6500mx25mpClockSource 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.3
int - internal clock source. ext - external clock source. newvalInt - same functionality as 'int', new enumeration added for RFc1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER int(0), ext(1), newvalInt(50)  

cdx6500mx25mpClockSpeed 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.4
This is the speed of the port in bits per second, when using internal clocking.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1200..80000  

cdx6500mx25mpStationCnt 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.5
The number of slave stations on the MX25 line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..32  

cdx6500mx25mpPollTimer 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.6
Worst case delay for a slave to respond to a poll frame sent by the master, including modem turn around time, etc. Value in 10ths of second ( 30 = 3.0 seconds ).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

cdx6500mx25mpPollPeriod 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.7
Time in milliseconds between polls when no data is exchanged.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 50..250  

cdx6500mx25mpTries 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.8
Maximum number of attempts to complete a transmission.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

cdx6500mx25mpRestartTimer 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.9
Restart-Request timeout timer in seconds. If timer expires, request is sent again.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 5..255  

cdx6500mx25mpResetTimer 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.10
Reset-Request timeout timer in seconds. If timer expires, request is sent again.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 5..255  

cdx6500mx25mpCallTimer 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.11
Call-Request timeout timer in seconds. If timer expires, call is cleared.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 5..200  

cdx6500mx25mpClearTimer 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.12
Clear-Request timeout timer in seconds. If timer expires, request is sent again.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 5..255  

cdx6500mx25mpPortControl 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.13
Specify any of the following port control options: NONE - no option specified. MB - raise Pin 22 when the port becomes disabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(2..8)  

cdx6500mx25mpTXEncoding 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.14
This is the data encoding used on the MX25 link. nrz - Non Return to Zero. nrzi - Non Return to Zero Inverted. newvalNrz : same functionality as 'nrz', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER nrz(0), nrzi(1), newvalNrz(50)  

cdx6500mx25mpElectricalInterfaceType 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.15
Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabled
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER v24(1), v35(2), v36(3), x21(4), none(5)  

cdx6500mx25mpV24ElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.16
Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ri(1), tm(2)  

cdx6500mx25mpHighSpeedElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.4.2.1.17
Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), xover(2)  

cdx6500PPCTMX25SPortTable 1.3.6.1.4.1.449.2.1.2.1.1.4.3
All of the configuration parameters relevant to the MX.25 Slave port table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PPCTMX25SPortEntry

cdx6500PPCTMX25SPortEntry 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1
A row of MX.25 Slave Port configuration parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500PPCTMX25SPortEntry  

cdx6500mx25spCfgPortNum 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.1
MX25 Port Number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500mx25spSubType 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.2
This is the mode in which this MX25 port will run.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER slave(1)  

cdx6500mx25spClockSource 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.3
int - internal clock source. ext - external clock source. newvalInt - same functionality as 'int', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER int(0), ext(1), newvalInt(50)  

cdx6500mx25spClockSpeed 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.4
This is the speed of the port in bits per second, when using internal clocking.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1200..80000  

cdx6500mx25spStationAddress 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.5
The station address on the multidrop line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..2)  

cdx6500mx25spPVCChannels 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.6
Number of logical channels used for Permanent Virtual Circuits. The total number of PVC and SVC channels on a link should be kept as small as possible and consistent with needs. PVC connections must be configured in the PVC Table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..128  

cdx6500mx25spStartingPVC 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.7
This is the starting logical channel number for the Permanent Virtual Circuits on this link. Not used if the number of PVCs = 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

cdx6500mx25spSVCChannels 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.8
Number of logical channels used in Switched Virtual Circuits. The total number of PVC and SVC channels on a link should be kept as small as possible and consistent with needs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cdx6500mx25spStartingSVC 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.9
This is the starting logical channel number for the Switched Virtual Circuits on this link. Not used if the number of SVCs = 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cdx6500mx25spPollTimer 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.10
Worst case delay for a slave to respond to a poll frame sent by the master, including modem turn around time, etc. Value in 10ths of second ( 30 = 3.0 seconds ).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

cdx6500mx25spTries 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.11
Maximum number of attempts to complete a transmission.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

cdx6500mx25spFrameWinSize 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.12
Frame level window size must be set to the same value in devices at each end of the link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7  

cdx6500mx25spPacketWinSize 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.13
Packet level window size must be set to the same value in devices at each end of the link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7  

cdx6500mx25spRestartTimer 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.14
Restart-Request timeout timer in seconds. If timer expires, request is sent again.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 5..255  

cdx6500mx25spResetTimer 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.15
Reset-Request timeout timer in seconds. If timer expires, request is sent again.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 5..255  

cdx6500mx25spCallTimer 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.16
Call-Request timeout timer in seconds. If timer expires, call is cleared.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 5..200  

cdx6500mx25spClearTimer 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.17
Clear-Request timeout timer in seconds. If timer expires, request is sent again.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 5..255  

cdx6500mx25spMX25Options 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.18
Select options on this MX.25 port as follows: NONE - no option specified. HOLD - hold calls over link restart. CUG - check closed user group; otherwise, CUG passes transparently. INL - inter-node link. Link goes to another 6500 device. INLA - set with INL option when an MX.25 link connection is to a 6500 node using 2.12.04 or earlier. DELAY - enable Delay and Path trace on this link (link must connected to Rel. 4.xx node) Any combination of the above specified by summing (e.g. HOLD+CUG+. . .).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(3..22)  

cdx6500mx25spRCDestination 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.19
All calls entering this port will be routed to the destination specified in this parameter, irrespective of route selection table entries. For example, to route calls to port 1, use P1. To route calls to port 2, station 4, use P2S4. Blank this field to disable this function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

cdx6500mx25spCUG 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.20
The port may be a member of up to 8 different Closed User Groups (CUGs). Each CUG membership must be a two digit number (except --) and separated by a comma. (e.g. 12,34,56,09,02,03 ). -- - No CUG Membership 00-99 - CUG Membership
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..23)  

cdx6500mx25spBillingRecords 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.21
This controls whether billing (accounting) records will be created for calls on this port. newvalOff - same functionality as 'off', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1), newvalOff(50)  

cdx6500mx25spPortControl 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.22
Specify any of the following port control options: NONE - no option specified. MB - raise Pin 22 when the port becomes disabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(2..8)  

cdx6500mx25spTXEncoding 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.23
This is the data encoding used on the MX25 link. nrz - Non Return to Zero. nrzi - Non Return to Zero Inverted. newvalNrz - same functionality as 'nrz', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER nrz(0), nrzi(1), newvalNrz(50)  

cdx6500mx25spUpperQueue 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.24
This is the maximum number of data packets a channel on this port will queue for transmission before invoking flow control to the attached channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 5..15  

cdx6500mx25spLowerQueue 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.25
This is the number of data packets a channel on this port will have queued for transmission when it releases flow control to the attached channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4  

cdx6500mx25spElectricalInterfaceType 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.26
Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabled
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER v24(1), v35(2), v36(3), x21(4), none(5)  

cdx6500mx25spV24ElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.27
Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ri(1), tm(2)  

cdx6500mx25spHighSpeedElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.4.3.1.28
Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), xover(2)  

cdx6500PPSTMX25PortTable 1.3.6.1.4.1.449.2.1.3.1.1.4
All of the statistics parameters relevant to the MX25 Port table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PPSTMX25PortEntry

cdx6500PPSTMX25PortEntry 1.3.6.1.4.1.449.2.1.3.1.1.4.1
A row of MX25 Port statistics parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500PPSTMX25PortEntry  

cdx6500mx25pStatsPortNum 1.3.6.1.4.1.449.2.1.3.1.1.4.1.1
Number of the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500mx25pPortStatus 1.3.6.1.4.1.449.2.1.3.1.1.4.1.2
Status of this port : Up - Port is active. Down - Port Is inactive. Disabled - An operator has disabled the port. Busy Out - an operator has busied out the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(2..8)  

cdx6500mx25pPortSpeed 1.3.6.1.4.1.449.2.1.3.1.1.4.1.3
This is the speed of the port when Clock=Int; this is the detected clock speed if Clock=Ext. If Port Speed is 0, Clock=Ext but clocking is not being received from attached device.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500mx25pCharInTotal 1.3.6.1.4.1.449.2.1.3.1.1.4.1.4
Number of characters received by the port since the last node, port, or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500mx25pCharOutTotal 1.3.6.1.4.1.449.2.1.3.1.1.4.1.5
Number of characters sent by the port since the last node, port, or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500mx25pCharsInPerSec 1.3.6.1.4.1.449.2.1.3.1.1.4.1.6
Summary of the characters being received over the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500mx25pCharsOutPerSec 1.3.6.1.4.1.449.2.1.3.1.1.4.1.7
Summary of the characters being sent over the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500mx25pFrameInTotal 1.3.6.1.4.1.449.2.1.3.1.1.4.1.8
Number of frames received by the port since the last node, port, or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500mx25pFrameOutTotal 1.3.6.1.4.1.449.2.1.3.1.1.4.1.9
Number of frames sent by the port since the last node, port, or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500mx25pFramesInPerSec 1.3.6.1.4.1.449.2.1.3.1.1.4.1.10
Summary of the frames being received over the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500mx25pFramesOutPerSec 1.3.6.1.4.1.449.2.1.3.1.1.4.1.11
Summary of the frames being sent over the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500SPCTMX25StationTable 1.3.6.1.4.1.449.2.1.2.1.3.1
All of the configuration parameters relevant to the MX.25 station table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500SPCTMX25StationEntry

cdx6500SPCTMX25StationEntry 1.3.6.1.4.1.449.2.1.2.1.3.1.1
A row of MX.25 station configuration parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500SPCTMX25StationEntry  

cdx6500mx25sCfgPortNum 1.3.6.1.4.1.449.2.1.2.1.3.1.1.1
MX25 Port Number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500mx25sCfgStationNum 1.3.6.1.4.1.449.2.1.2.1.3.1.1.2
The number of the controller on the multidrop line. Also used for routing purposes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

cdx6500mx25sStationAddress 1.3.6.1.4.1.449.2.1.2.1.3.1.1.3
The station address on the multidrop line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..2)  

cdx6500mx25sPVCChannels 1.3.6.1.4.1.449.2.1.2.1.3.1.1.4
Number of logical channels used for Permanent Virtual Circuits. The total number of PVC and SVC channels on a link should be kept as small as possible and consistent with needs. PVC connections must be configured in the PVC Table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..128  

cdx6500mx25sStartingPVC 1.3.6.1.4.1.449.2.1.2.1.3.1.1.5
This is the starting logical channel number for the Permanent Virtual Circuits on this link. Not used if the number of PVCs = 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

cdx6500mx25sSVCChannels 1.3.6.1.4.1.449.2.1.2.1.3.1.1.6
Number of logical channels used in Switched Virtual Circuits. The total number of PVC and SVC channels on a link should be kept as small as possible and consistent with needs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cdx6500mx25sStartingSVC 1.3.6.1.4.1.449.2.1.2.1.3.1.1.7
This is the starting logical channel number for the Switched Virtual Circuits on this link. Not used if the number of SVCs = 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cdx6500mx25sFrameWinSize 1.3.6.1.4.1.449.2.1.2.1.3.1.1.8
Frame level window size must be set to the same value in devices at each end of the link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7  

cdx6500mx25sPacketWinSize 1.3.6.1.4.1.449.2.1.2.1.3.1.1.9
Packet level window size must be set to the same value in devices at each end of the link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7  

cdx6500mx25sMX25Options 1.3.6.1.4.1.449.2.1.2.1.3.1.1.10
Select options on this MX.25 port as follows: NONE - no option specified HOLD - hold calls over link restart CUG - check closed user group; otherwise, CUG passes transparently INL - inter-node link. Link goes to another 6500 device INLA - set with INL option when an MX.25 link connection is to a 6500 node using 2.12.04 or earlier Any combination of the above specified by summing (e.g. HOLD+CUG+. . .).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(3..22)  

cdx6500mx25sRCDestination 1.3.6.1.4.1.449.2.1.2.1.3.1.1.11
All calls entering this port will be routed to the destination specified in this parameter, irrespective of route selection table entries. For example, to route calls to port 1, use P1. To route calls to port 2, station 4, use P2S4. Blank this field to disable this function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

cdx6500mx25sCUG 1.3.6.1.4.1.449.2.1.2.1.3.1.1.12
The port may be a member of up to 8 different Closed User Groups (CUGs). Each CUG membership must be a two digit number (except --) and separated by a comma. (e.g. 12,34,56,09,02,03). -- - No CUG Membership 00-99 - CUG Membership
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..23)  

cdx6500mx25sBillingRecords 1.3.6.1.4.1.449.2.1.2.1.3.1.1.13
This controls whether billing (accounting) records will be created for calls on this port. newvalOff - same functionality as 'off', new enumeration added for RFc1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1), newvalOff(50)  

cdx6500mx25sUpperQueue 1.3.6.1.4.1.449.2.1.2.1.3.1.1.14
This is the maximum number of data packets a channel on this port will queue for transmission before invoking flow control to the attached channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 5..15  

cdx6500mx25sLowerQueue 1.3.6.1.4.1.449.2.1.2.1.3.1.1.15
This is the number of data packets a channel on this port will have queued for transmission when it releases flow control to the attached channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4  

cdx6500SPSTMX25StationTable 1.3.6.1.4.1.449.2.1.3.1.3.1
All of the statistics parameters relevant to the MX25 Station table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500SPSTMX25StationEntry

cdx6500SPSTMX25StationEntry 1.3.6.1.4.1.449.2.1.3.1.3.1.1
A row of MX25 Station statistics parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500SPSTMX25StationEntry  

cdx6500mx25sStatsPortNum 1.3.6.1.4.1.449.2.1.3.1.3.1.1.1
Number of the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500mx25sStatsStationNum 1.3.6.1.4.1.449.2.1.3.1.3.1.1.2
Station reference number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

cdx6500mx25sStatsStnAddr 1.3.6.1.4.1.449.2.1.3.1.3.1.1.3
Configured station address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..2)  

cdx6500mx25sCharInTotal 1.3.6.1.4.1.449.2.1.3.1.3.1.1.4
Number of characters received by the port since the last node, port, or statistics reset
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500mx25sCharOutTotal 1.3.6.1.4.1.449.2.1.3.1.3.1.1.5
Number of characters sent by the port since the last node, port, or statistics reset
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500mx25sCharsInPerSec 1.3.6.1.4.1.449.2.1.3.1.3.1.1.6
Summary of the characters being received over the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500mx25sCharsOutPerSec 1.3.6.1.4.1.449.2.1.3.1.3.1.1.7
Summary of the characters being sent over the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500mx25sFrameInTotal 1.3.6.1.4.1.449.2.1.3.1.3.1.1.8
Number of frames received by the port since the last node, port, or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500mx25sFrameOutTotal 1.3.6.1.4.1.449.2.1.3.1.3.1.1.9
Number of frames sent by the port since the last node, port, or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500mx25sFramesInPerSec 1.3.6.1.4.1.449.2.1.3.1.3.1.1.10
Summary of the frames being received over the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500mx25sFramesOutPerSec 1.3.6.1.4.1.449.2.1.3.1.3.1.1.11
Summary of the frames being sent over the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500mx25sCallCount 1.3.6.1.4.1.449.2.1.3.1.3.1.1.12
Current number of calls.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500ContMX25StationTable 1.3.6.1.4.1.449.2.1.4.6.1
All of the control parameters relevant to the MX25 Station table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500ContMX25StationEntry

cdx6500ContMX25StationEntry 1.3.6.1.4.1.449.2.1.4.6.1.1
A row of MX25 Station Control parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500ContMX25StationEntry  

cdx6500mx25sContPortNum 1.3.6.1.4.1.449.2.1.4.6.1.1.1
MX25 Port Number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500mx25sContStationNum 1.3.6.1.4.1.449.2.1.4.6.1.1.2
MX25 Station Number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..4  

cdx6500mx25sContBootStation 1.3.6.1.4.1.449.2.1.4.6.1.1.3
Boots the specified MX25 station. boot - Boot Station. noBoot - Do not boot Station.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER boot(1), noBoot(2)  

cdx6500mx25sContDisableStation 1.3.6.1.4.1.449.2.1.4.6.1.1.4
Disables the specified MX25 station. disable - Disable Station. noDisable - Do not disable Station.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER disable(1), noDisable(2)  

cdx6500mx25sContEnableStation 1.3.6.1.4.1.449.2.1.4.6.1.1.5
Enables the specified MX25 station. enable - Enable Station. noEnable - Do not enable Station.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER enable(1), noEnable(2)  

cdx6500mx25sContBusyOutStation 1.3.6.1.4.1.449.2.1.4.6.1.1.6
Busy outs the specified MX25 station. busyOut - Busyout Station. noBusyOut - Do not busyout Station.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER busyOut(1), noBusyOut(2)  

cdx6500mx25sContResetStnStats 1.3.6.1.4.1.449.2.1.4.6.1.1.7
Busy outs the specified MX25 station. reset - Reset Station Statistics. noReset - Do not reset Station Statistics.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER reset(1), noReset(2)