MICROSENS-G6-NOTIFICATION-MIB

File: MICROSENS-G6-NOTIFICATION-MIB.mib (55862 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC RFC-1215

Imported symbols

MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
Integer32 enterprises DisplayString
MacAddress TRAP-TYPE

Defined Values

microsens 1.3.6.1.4.1.3181
Microsens private NOTIFICATION for Generation 6 Software Platform
MODULE-IDENTITY    

managedSwitches 1.3.6.1.4.1.3181.10
OBJECT IDENTIFIER    

g6 1.3.6.1.4.1.3181.10.6
OBJECT IDENTIFIER    

g6TrapGroup 1.3.6.1.4.1.3181.10.6.1
OBJECT IDENTIFIER    

g6Trap 1.3.6.1.4.1.3181.10.6.1.1
OBJECT IDENTIFIER    

g6TrapObjects 1.3.6.1.4.1.3181.10.6.1.2
OBJECT IDENTIFIER    

g6TrapObjEventName 1.3.6.1.4.1.3181.10.6.1.2.1
Event name as text string.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

g6TrapObjGroupName 1.3.6.1.4.1.3181.10.6.1.2.2
Event group as text string.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER internal(0), debug(2), test(3), reset(4), firmware(5), system(6), config(7), login(8), auth(9), power(10), temperature(11), link(12), sfp(13), poe(14), ring(15), ntp(16), signals(17), script(18), filter(19), lacp(20), app(21), cable(22), security(23), msp1000(24), backup(25), fan(26), messaging(27), terminalserver(28), smartoffice(29)  

g6TrapObjRelevance 1.3.6.1.4.1.3181.10.6.1.2.3
pos neg info
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER positive(0), negative(1), information(2)  

g6TrapObjSeverity 1.3.6.1.4.1.3181.10.6.1.2.4
Severity level of this event.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(0), debug(1), info(2), notice(3), warning(4), error(5), critical(6), alert(7), emergency(8)  

g6TrapObjSource 1.3.6.1.4.1.3181.10.6.1.2.5
Unit or port related event.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unit(0), port(1)  

g6TrapObjSysName 1.3.6.1.4.1.3181.10.6.1.2.6
User defined system name of the device originating this event.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

g6TrapObjPortId 1.3.6.1.4.1.3181.10.6.1.2.7
Port identification in snmp compliant integer format. Value is calculated as (slot * 100) + port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

g6TrapObjPortString 1.3.6.1.4.1.3181.10.6.1.2.8
Port identification in slot/port notation.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

g6TrapObjPortAlias 1.3.6.1.4.1.3181.10.6.1.2.9
Port identification using a possible user assigned alias or nickname.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

g6TrapObjDescription 1.3.6.1.4.1.3181.10.6.1.2.10
Detailed human readable full description of the event.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

g6TrapObjMac 1.3.6.1.4.1.3181.10.6.1.2.11
MAC address related with authentication trap.
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

g6TrapObjVlanId 1.3.6.1.4.1.3181.10.6.1.2.12
Associated VLAN id.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

g6TrapObjOfficeGroupName 1.3.6.1.4.1.3181.10.6.1.2.13
SmartOffice actor or sensor group name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

g6TrapObjAvgValue 1.3.6.1.4.1.3181.10.6.1.2.14
SmartOffice group data value. Contains the average value of all elements in the same group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

g6TrapObjTotalValue 1.3.6.1.4.1.3181.10.6.1.2.15
SmartOffice group data value. Contains the total value of all elements in the same group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

g6TrapDebug 1.3.6.1.4.1.3181.10.6.1.1.3
Internal Debug Messages.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapAliveTest 1.3.6.1.4.1.3181.10.6.1.1.4
Can be used to check out event and notification system with no effect to the system operation.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapFirmwareUpdateOk 1.3.6.1.4.1.3181.10.6.1.1.5
Firmware installation has successfully taken place.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapFirmwareUpdateFail 1.3.6.1.4.1.3181.10.6.1.1.6
Firmware installation has FAILED.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapLicenseViolation 1.3.6.1.4.1.3181.10.6.1.1.7
Firmware is used for which no license has been granted. Please contact sales representant.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapColdStart 1.3.6.1.4.1.3181.10.6.1.1.8
The device has booted. Data transmission was interrupted.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapWarmStart 1.3.6.1.4.1.3181.10.6.1.1.9
The device has (partially) booted without interupting data transmission services.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapFactoryReset 1.3.6.1.4.1.3181.10.6.1.1.10
Configuration factory reset is executed via local push button on the device.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapConfigurationLoaded 1.3.6.1.4.1.3181.10.6.1.1.11
All or a specific configuration file(s) has been restored and activated.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapChangeConfig 1.3.6.1.4.1.3181.10.6.1.1.12
A configuration parameter has been modified and activated.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapChangeOfflineConfig 1.3.6.1.4.1.3181.10.6.1.1.13
An offline configuration parameter has been modified. The running system is not affected.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapActionResponse 1.3.6.1.4.1.3181.10.6.1.1.14
Not a customer event. Contains the reponse string to an action command.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapCommitConfig 1.3.6.1.4.1.3181.10.6.1.1.15
Not a customer event. Recent configuration changes should now be stored and activated.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapPowerSupplyOk 1.3.6.1.4.1.3181.10.6.1.1.16
Power supply has been restored. Applies to units with redundant supplies only.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapPowerSupplyFail 1.3.6.1.4.1.3181.10.6.1.1.17
Power supply has FAILED. Applies to units with redundant supplies only.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapLogin 1.3.6.1.4.1.3181.10.6.1.1.18
An operator has logged onto the system.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapLogout 1.3.6.1.4.1.3181.10.6.1.1.19
An operator has logged off from the system.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapLoginAttempt 1.3.6.1.4.1.3181.10.6.1.1.20
An operator login has failed due to invalid login or password.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapLinkUp 1.3.6.1.4.1.3181.10.6.1.1.21
A port has gone online and is ready to transport data.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapLinkDown 1.3.6.1.4.1.3181.10.6.1.1.22
A port has gone down. Data transport on this port is no longer possible.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapRingNormal 1.3.6.1.4.1.3181.10.6.1.1.23
A ring is back to normal operation. Protection is available.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapRingBackup 1.3.6.1.4.1.3181.10.6.1.1.24
A ring has switched to the redundant backup path.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapRingFailure 1.3.6.1.4.1.3181.10.6.1.1.25
A ring has FAILED. Normal and backup path are unavailable.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapCouplingState 1.3.6.1.4.1.3181.10.6.1.1.26
Coupling controller state change.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapTemperatureOk 1.3.6.1.4.1.3181.10.6.1.1.27
Operating temperature is within acceptable limits.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapTemperatureWarning 1.3.6.1.4.1.3181.10.6.1.1.28
Operating temperature is low or high. Performance my be degraded. Do not run under this condition for prolonged time.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapTemperatureFailure 1.3.6.1.4.1.3181.10.6.1.1.29
Operating temperature is too low or too high. The unit may switch itself off to protect itself anytime soon.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapMacAccepted 1.3.6.1.4.1.3181.10.6.1.1.30
A MAC address has been authorized.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapMacAuthError 1.3.6.1.4.1.3181.10.6.1.1.31
MAC authorization error.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapMacBlocked 1.3.6.1.4.1.3181.10.6.1.1.32
A MAC address has been blocked.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapMacBlockedVlan 1.3.6.1.4.1.3181.10.6.1.1.33
A MAC address has been blocked. Assigned to unauthorized VLAN.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapMacDisconnected 1.3.6.1.4.1.3181.10.6.1.1.34
A MAC address has been disconnected.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapSfpInserted 1.3.6.1.4.1.3181.10.6.1.1.35
An SFP (pluggable optical or electrical port module) has been inserted.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapSfpRemoved 1.3.6.1.4.1.3181.10.6.1.1.36
An SFP (pluggable optical or electrical port module) has been removed from the device.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapSfpSignalPresent 1.3.6.1.4.1.3181.10.6.1.1.37
An SFP (pluggable optical or electrical port module) has detected an optical receive signal.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapSfpSignalLoss 1.3.6.1.4.1.3181.10.6.1.1.38
An SFP (pluggable optical or electrical port module) has lost its receive signal.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapSfpSignalChange 1.3.6.1.4.1.3181.10.6.1.1.39
An SFP (pluggable optical or electrical port module) has detected a change in the optical input power level.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapSfpMismatch 1.3.6.1.4.1.3181.10.6.1.1.40
An SFP (pluggable optical or electrical port module) has been inserted which does not match the required feature(s).
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapPoeConnect 1.3.6.1.4.1.3181.10.6.1.1.41
A POE (Power over Ethernet) device is connected an powered.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapPoeVoltage 1.3.6.1.4.1.3181.10.6.1.1.42
The POE (Power over Ethernet) operating voltage is too low.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapPoeError 1.3.6.1.4.1.3181.10.6.1.1.43
A POE (Power over Ethernet) error has occurred.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapPoeClassmismatch 1.3.6.1.4.1.3181.10.6.1.1.44
A POE (Power over Ethernet) powered device requires a power level not enabled or available at this port.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapPoeDisconnect 1.3.6.1.4.1.3181.10.6.1.1.45
A POE (Power over Ethernet) device has been disconnected.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapNtpFail 1.3.6.1.4.1.3181.10.6.1.1.46
The NTP client (Network Time Protocol) has a failure condition.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapHardwareError 1.3.6.1.4.1.3181.10.6.1.1.47
A hardware error has been detected.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapSoftwareError 1.3.6.1.4.1.3181.10.6.1.1.48
A software error has occured.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapButtonPressed 1.3.6.1.4.1.3181.10.6.1.1.49
System button pressed.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapInputSignalNormal 1.3.6.1.4.1.3181.10.6.1.1.67
An external input signal has been deactivated and returned to normal state.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapInputSignalActivated 1.3.6.1.4.1.3181.10.6.1.1.68
An external input signal has been activated.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapOutputRelayNormal 1.3.6.1.4.1.3181.10.6.1.1.69
A relay output signal has been deactivated and returned to normal state.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapOutputRelayActivated 1.3.6.1.4.1.3181.10.6.1.1.70
An external input signal has been deactivated and returned to normal state.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapPacketIntercepted 1.3.6.1.4.1.3181.10.6.1.1.71
Special filter has intercepted a data packet.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapScriptUnitPositive 1.3.6.1.4.1.3181.10.6.1.1.72
A positive unit related user defined event created by script or app.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapScriptUnitNegative 1.3.6.1.4.1.3181.10.6.1.1.73
A negative unit related user defined event created by script or app.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapScriptPortPositive 1.3.6.1.4.1.3181.10.6.1.1.74
A positive port related user defined event created by script or app.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapScriptPortNegative 1.3.6.1.4.1.3181.10.6.1.1.75
A negative port related user defined event created by script or app.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapScriptExecuted 1.3.6.1.4.1.3181.10.6.1.1.76
A user defined script execution started.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapScriptError 1.3.6.1.4.1.3181.10.6.1.1.77
Script execution error of a user defined script.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapLoopRemoved 1.3.6.1.4.1.3181.10.6.1.1.78
Cable loop removed. Port unblocked.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapLoopDetected 1.3.6.1.4.1.3181.10.6.1.1.79
Cable loop detected. Port blocked.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapLacpConnect 1.3.6.1.4.1.3181.10.6.1.1.80
Aggregated link established.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapLacpDisconnect 1.3.6.1.4.1.3181.10.6.1.1.81
Aggregated link down.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapAppInstalled 1.3.6.1.4.1.3181.10.6.1.1.82
App installed ok.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapAppInstallationFail 1.3.6.1.4.1.3181.10.6.1.1.83
App installation has failed.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapAppDeinstalled 1.3.6.1.4.1.3181.10.6.1.1.84
App deinstalled.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapCableChangeDetected 1.3.6.1.4.1.3181.10.6.1.1.85
Change in cable termination detected.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapImplausibleConfig 1.3.6.1.4.1.3181.10.6.1.1.86
Implausible configuration detected
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapNetworkAttack 1.3.6.1.4.1.3181.10.6.1.1.87
Potential network attack detected
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapModuleInserted 1.3.6.1.4.1.3181.10.6.1.1.88
A hardware module has been inserted into the system.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapModuleRemoved 1.3.6.1.4.1.3181.10.6.1.1.89
A hardware module has been removed from the system.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapMsp1000UnitPositive 1.3.6.1.4.1.3181.10.6.1.1.90
A positive MSP1000 unit related event has occured.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapMsp1000UnitNegative 1.3.6.1.4.1.3181.10.6.1.1.91
A negative MSP1000 unit related event has occured.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapMsp1000PortPositive 1.3.6.1.4.1.3181.10.6.1.1.92
A positive MSP1000 port related event has occured.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapMsp1000PortNegative 1.3.6.1.4.1.3181.10.6.1.1.93
A negative MSP1000 port related event has occured.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapBackupTerminated 1.3.6.1.4.1.3181.10.6.1.1.94
Backup path not required.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapBackupEngaged 1.3.6.1.4.1.3181.10.6.1.1.95
Backup path has been engaged.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapBackupFailure 1.3.6.1.4.1.3181.10.6.1.1.96
Backup path could not be completed.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapFanOk 1.3.6.1.4.1.3181.10.6.1.1.97
Cooling fan operating normally.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapFanDegraded 1.3.6.1.4.1.3181.10.6.1.1.98
Cooling fan degraded. Replace fan soon.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapFanFailure 1.3.6.1.4.1.3181.10.6.1.1.99
Cooling fan failed. Replace fan immediately
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapIncomingAlert 1.3.6.1.4.1.3181.10.6.1.1.100
Externally received HTTP_GET_REQUEST or received SNMP TRAP.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapCableTerminationEstablished 1.3.6.1.4.1.3181.10.6.1.1.101
Cable termination established. Possible reason: A terminated remote device was connected to the cable.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapCableTerminationLost 1.3.6.1.4.1.3181.10.6.1.1.102
Cable termination lost. Possible reason: A terminated remote device was disconnected from the cable or the cable was locally unplugged.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapTerminalServerConnected 1.3.6.1.4.1.3181.10.6.1.1.103
Terminal server connected foreign host to local serial port.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapTerminalServerDisconnected 1.3.6.1.4.1.3181.10.6.1.1.104
Terminal server disconnected foreign host from local serial port.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapTerminalServerFail 1.3.6.1.4.1.3181.10.6.1.1.105
Terminal server failed in connecting foreign host to local serial port.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapSensorGroupChange 1.3.6.1.4.1.3181.10.6.1.1.108
Sensor group values have changed.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapActorGroupChangeRequest 1.3.6.1.4.1.3181.10.6.1.1.110
Actor group is requested to change to a new value.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapRegisterSmartDevice 1.3.6.1.4.1.3181.10.6.1.1.111
A new smart device is registered.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapUpdateSmartDevice 1.3.6.1.4.1.3181.10.6.1.1.112
A smart device has changed its status.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapRegisterSmartAttribute 1.3.6.1.4.1.3181.10.6.1.1.115
A new smart attribute is registered.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapUnregisterSmartDevice 1.3.6.1.4.1.3181.10.6.1.1.117
A smart device is unregistered.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapUnregisterSmartAttribute 1.3.6.1.4.1.3181.10.6.1.1.118
A smart attribute is unregistered.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapSingleActorChange 1.3.6.1.4.1.3181.10.6.1.1.119
An individual actor is set to a new value.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapActorGroupChanged 1.3.6.1.4.1.3181.10.6.1.1.120
An actor group has changed to a new value.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapSmartOfficeInitializing 1.3.6.1.4.1.3181.10.6.1.1.121
Smart Office is being initialized.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapSmartOfficeStarted 1.3.6.1.4.1.3181.10.6.1.1.122
Smart Office is started and ready.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapSmartOfficeStopped 1.3.6.1.4.1.3181.10.6.1.1.123
Smart Office is being stopped.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapSmartOfficeError 1.3.6.1.4.1.3181.10.6.1.1.124
A Smart Office error has occured.
Status: current Access: read-only
NOTIFICATION-TYPE    

g6TrapOtdrMeasurements 1.3.6.1.4.1.3181.10.6.1.1.125
An OTDR measurement has taken place and detected a change in the optical characteristics of the cable.
Status: current Access: read-only
NOTIFICATION-TYPE