MICROSEMI-PDSINE-MIB

File: MICROSEMI-PDSINE-MIB.mib (16037 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC RFC1155-SMI

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
Gauge32 Counter32 NOTIFICATION-TYPE
TruthValue enterprises

Defined Types

PortEntry  
SEQUENCE    
  portGroupIndex Integer32
  portIndex Integer32
  portConsumptionPower Gauge32
  portMaxPower Integer32
  portType INTEGER

MainPseEntry  
SEQUENCE    
  mainGroupIndex Integer32
  mainVoltage Gauge32
  mainDetectionMethod INTEGER
  mainPowerUsageBudget Integer32
  mainPSEMaxPower Gauge32
  highPowerLegacyPDSupport INTEGER
  highPowerExtendedPortPower INTEGER
  powerBackupStatus INTEGER
  internalPowerSourceStatus INTEGER
  externalPowerSourceStatus INTEGER
  temperature INTEGER
  temperatureformat INTEGER

Defined Values

polPowerOverLan 1.3.6.1.4.1.7428
Tok_String
MODULE-IDENTITY    

products 1.3.6.1.4.1.7428.1
OBJECT IDENTIFIER    

description 1.3.6.1.4.1.7428.1.1
OBJECT IDENTIFIER    

sysObjectID 1.3.6.1.4.1.7428.1.1.1
OBJECT IDENTIFIER    

pseDevice 1.3.6.1.4.1.7428.1.2
OBJECT IDENTIFIER    

portObjects 1.3.6.1.4.1.7428.1.2.1
OBJECT IDENTIFIER    

mainObjects 1.3.6.1.4.1.7428.1.2.2
OBJECT IDENTIFIER    

poeNotifications 1.3.6.1.4.1.7428.1.3
OBJECT IDENTIFIER    

midspanUnknown 1.3.6.1.4.1.7428.1.1.1.1
OBJECT IDENTIFIER    

midspan6portAC 1.3.6.1.4.1.7428.1.1.1.2
OBJECT IDENTIFIER    

midspan6portACDC 1.3.6.1.4.1.7428.1.1.1.3
OBJECT IDENTIFIER    

midspan12portAC 1.3.6.1.4.1.7428.1.1.1.4
OBJECT IDENTIFIER    

midspan12portACDC 1.3.6.1.4.1.7428.1.1.1.5
OBJECT IDENTIFIER    

midspan24portAC 1.3.6.1.4.1.7428.1.1.1.6
OBJECT IDENTIFIER    

midspan24portACDC 1.3.6.1.4.1.7428.1.1.1.7
OBJECT IDENTIFIER    

midspan48portAC 1.3.6.1.4.1.7428.1.1.1.8
OBJECT IDENTIFIER    

midspan48portACDC 1.3.6.1.4.1.7428.1.1.1.9
OBJECT IDENTIFIER    

midspan6portHPAC 1.3.6.1.4.1.7428.1.1.1.10
OBJECT IDENTIFIER    

midspan6portHPACDC 1.3.6.1.4.1.7428.1.1.1.11
OBJECT IDENTIFIER    

midspan12portHPAC 1.3.6.1.4.1.7428.1.1.1.12
OBJECT IDENTIFIER    

midspan12portHPACDC 1.3.6.1.4.1.7428.1.1.1.13
OBJECT IDENTIFIER    

midspanGigabit6portAC 1.3.6.1.4.1.7428.1.1.1.14
OBJECT IDENTIFIER    

midspanGigabit12portAC 1.3.6.1.4.1.7428.1.1.1.15
OBJECT IDENTIFIER    

midspanGigabit24portAC 1.3.6.1.4.1.7428.1.1.1.16
OBJECT IDENTIFIER    

midspanHiPoEGigabit6portAC 1.3.6.1.4.1.7428.1.1.1.17
OBJECT IDENTIFIER    

midspanHiPoEGigabit12portAC 1.3.6.1.4.1.7428.1.1.1.18
OBJECT IDENTIFIER    

midspanHiPoEGigabit24portAC 1.3.6.1.4.1.7428.1.1.1.19
OBJECT IDENTIFIER    

midspanHiPoEATGigabit6portAC 1.3.6.1.4.1.7428.1.1.1.20
OBJECT IDENTIFIER    

midspanHiPoEATGigabit12portACDC 1.3.6.1.4.1.7428.1.1.1.21
OBJECT IDENTIFIER    

midspanHiPoEATGigabit24portACDC 1.3.6.1.4.1.7428.1.1.1.22
OBJECT IDENTIFIER    

midspan4PairATGigabit6portACDC 1.3.6.1.4.1.7428.1.1.1.23
OBJECT IDENTIFIER    

midspan4PairATGigabit12portACDC 1.3.6.1.4.1.7428.1.1.1.24
OBJECT IDENTIFIER    

midspanHiPoEATGigabit6portDC 1.3.6.1.4.1.7428.1.1.1.25
OBJECT IDENTIFIER    

midspanHiPoEATGigabit12portDC 1.3.6.1.4.1.7428.1.1.1.26
OBJECT IDENTIFIER    

midspanHiPoEATGigabit24portDC 1.3.6.1.4.1.7428.1.1.1.27
OBJECT IDENTIFIER    

midspan4PairATGigabit24portACDC 1.3.6.1.4.1.7428.1.1.1.28
OBJECT IDENTIFIER    

midspanEEPoEGigabit24portACDC 1.3.6.1.4.1.7428.1.1.1.29
OBJECT IDENTIFIER    

midspanPoHGigabit6portACDC 1.3.6.1.4.1.7428.1.1.1.30
OBJECT IDENTIFIER    

midspanPoHGigabit12portACDC 1.3.6.1.4.1.7428.1.1.1.31
OBJECT IDENTIFIER    

midspanPoHGigabit24portACDC 1.3.6.1.4.1.7428.1.1.1.32
OBJECT IDENTIFIER    

portTable 1.3.6.1.4.1.7428.1.2.1.1
A table of objects that display and control the power characteristics of power Ethernet ports on a Power Source Entity (PSE) device. This group will be implemented in managed power Ethernet switches and mid-span devices. Values of all read-write objects in this table are persistent at restart/reboot.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PortEntry

portEntry 1.3.6.1.4.1.7428.1.2.1.1.1
A set of objects that display and control the power characteristics of a power Ethernet PSE port.
Status: current Access: not-accessible
OBJECT-TYPE    
  PortEntry  

portGroupIndex 1.3.6.1.4.1.7428.1.2.1.1.1.1
This variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

portIndex 1.3.6.1.4.1.7428.1.2.1.1.1.2
This variable uniquely identifies the power Ethernet PSE port within group portGroupIndex to which the power Ethernet PSE entry is connected.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

portConsumptionPower 1.3.6.1.4.1.7428.1.2.1.1.1.3
A read-only value indicates the measured usage power expressed in Watts for a specific port
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

portMaxPower 1.3.6.1.4.1.7428.1.2.1.1.1.4
Read/Write maximum power consumption that PD device may consume in Watts NOTE: 1. For Midspan 60xx,60xxG,6500 series, Max PD power consumption = 17Watt 2. For Midspan 70xxG series, Max PD power consumption = 30Watt 3 .For Midspan 80xx series, this parameter is read-only !! 4. For Midspan 90xxG series, Max PD power consumption = 30/36Watt 5. For Midspan 95xxG series, Max PD power consumption = 60/72Watt (four pair) or 30/36Watt (two pair) 6. For Midspan 55xxG series, Max PD power consumption = 30/36Watt
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..99  

portType 1.3.6.1.4.1.7428.1.2.1.1.1.5
Enable/Disable Four-pair/EEPoE PoE Read : Applicable to all Midspan series Write: Applicable only to 95xxG/55xxG Midspan series twopair (1) Two-pair PoE port capable of providing up to 16.8Watt or 30-36Watt. fourpair (2) Four-pair/EEPoE-mode PoE port capable of providing up to 60-72Watt (95xxG) or 30-36W (55xxG).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER twopair(1), fourpair(2)  

mainPseTable 1.3.6.1.4.1.7428.1.2.2.1
A table of objects that display and control attributes of the main PSE device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MainPseEntry

mainPseEntry 1.3.6.1.4.1.7428.1.2.2.1.1
A set of objects that display and control the Main PSE device.
Status: current Access: not-accessible
OBJECT-TYPE    
  MainPseEntry  

mainGroupIndex 1.3.6.1.4.1.7428.1.2.2.1.1.1
This variable uniquely identifies the group to which power Ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

mainVoltage 1.3.6.1.4.1.7428.1.2.2.1.1.2
Power Supply Voltage in Volt.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 1..65535  

mainDetectionMethod 1.3.6.1.4.1.7428.1.2.2.1.1.3
Read/Write PD device detection method (802.3af / 802.3af+Legacy).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ieee8023afat(1), ieee8023afatandlegacy(2)  

mainPowerUsageBudget 1.3.6.1.4.1.7428.1.2.2.1.1.4
Allow external SNMP manager to limit maximum power that all PD's may consume Whenever total power consumption exceeds maximum power, Midspan may turn off automatically Low priority and High priority PSE ports. Percentage Value refers to Midspan maximum power.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 10..100  

mainPSEMaxPower 1.3.6.1.4.1.7428.1.2.2.1.1.5
Maximum power that Midspan can provide (Watt), after including power budget percentage limitation. Example: Midspan maximum power without power limit = 860Watt, and Power Limit = 50% mainPSEMaxPower = 430Watt
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 1..65535  

highPowerLegacyPDSupport 1.3.6.1.4.1.7428.1.2.2.1.1.6
Applicable only for Midspan 90xxG series enable (1) - Power Cisco 125x access point (pre 802.3at legacy high power PD device). disable(2) - Power only 802.3at compliant devices. notsupported(3) - SNMP GET result for Midspan which doesn't support this feature
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), notsupported(3)  

highPowerExtendedPortPower 1.3.6.1.4.1.7428.1.2.2.1.1.7
Applicable only for Midspan 90xxG/55xxG series enable (1) - Extend maximum power to PD device beyond 802.3at specification. disable(2) - Maximum power to PD device per 802.3at specification. notsupported(3) - SNMP GET result for Midspan which doesn't support this feature
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), notsupported(3)  

powerBackupStatus 1.3.6.1.4.1.7428.1.2.2.1.1.8
Applicable only for Midspan 90xxG/95xxG/55xxG series standalone - Midspan isn't connected to any power backup device powerbackupbyrps - Redundant power supply (RPS) backup Midspan device powerbackupbymidspan - Two Midspan devices backup each other incompatiblepowerbackupdevice - Midspan was connected to incompatible power backup device. For example RPS 430Watt to Midspan 950Watt
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER standalone(1), powerbackupbyrps(2), powerbackupbymidspan(3), incompatiblepowerbackupdevice(4)  

internalPowerSourceStatus 1.3.6.1.4.1.7428.1.2.2.1.1.9
Applicable only for Midspan 90xxG/95xxG/55xxG series ok(1) - Internal Power Source is OK fail(2) - Internal Power Source failure
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), fail(2)  

externalPowerSourceStatus 1.3.6.1.4.1.7428.1.2.2.1.1.10
Applicable only for Midspan 90xxG/95xxG/55xxG series ok(1) - External Power Source is OK fail(2) - External Power Source failure notsupported(3) - SNMP GET result for Midspan which doesn't support this feature
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), fail(2), notsupported(3)  

temperature 1.3.6.1.4.1.7428.1.2.2.1.1.11
Unit temperature - Applicable only for Midspan 95xxG series
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

temperatureformat 1.3.6.1.4.1.7428.1.2.2.1.1.12
Unit temperature format - Applicable only for Midspan 95xxG series Celcius(1) - Report unit temperature in Celcius Fahrenheit(2) - Report unit temperature in Fahrenheit NotSupported(3) - No temperature sensor inside the Midspan unit
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER celcius(1), fahrenheit(2), notsupported(3)  

powerBackupStatusNotification 1.3.6.1.4.1.7428.1.3.1
Applicable only for Midspan 90xxG/95xxG/55xxG series This Notification reports power backup status change, and whenever incompatible power backup source is connected (as RPS 430Watt to Midspan 950Watt)
Status: current Access: read-write
NOTIFICATION-TYPE    

internalPowerSourceStatusNotification 1.3.6.1.4.1.7428.1.3.2
Applicable only for Midspan 90xxG/95xxG/55xxG series This Notification reports internal Power Source failure
Status: current Access: read-write
NOTIFICATION-TYPE    

externalPowerSourceStatusNotification 1.3.6.1.4.1.7428.1.3.3
Applicable only for Midspan 90xxG/95xxG/55xxG series This Notification reports external Power Source failure
Status: current Access: read-write
NOTIFICATION-TYPE