LLDP-EXT-PNO-MIB

File: LLDP-EXT-PNO-MIB.mib (19712 bytes)

Imported modules

SNMP-FRAMEWORK-MIB SNMPv2-SMI SNMPv2-TC
SNMPv2-CONF LLDP-MIB

Imported symbols

SnmpAdminString Unsigned32 MODULE-IDENTITY
OBJECT-TYPE DisplayString TruthValue
MODULE-COMPLIANCE OBJECT-GROUP lldpExtensions
lldpRemTimeMark lldpRemLocalPortNum lldpRemIndex
lldpPortConfigEntry lldpLocPortNum

Defined Types

LldpXPnoConfigEntry  
SEQUENCE    
  lldpXPnoConfigSPDTxEnable TruthValue
  lldpXPnoConfigPortStatusTxEnable TruthValue
  lldpXPnoConfigAliasTxEnable TruthValue
  lldpXPnoConfigMrpTxEnable TruthValue

LldpXPnoLocEntry  
SEQUENCE    
  lldpXPnoLocLPDValue Unsigned32
  lldpXPnoLocPortTxDValue Unsigned32
  lldpXPnoLocPortRxDValue Unsigned32
  lldpXPnoLocPortStatusRT2 INTEGER
  lldpXPnoLocPortStatusRT3 INTEGER
  lldpXPnoLocPortNoS DisplayString
  lldpXPnoLocPortMrpUuId OCTET STRING
  lldpXPnoLocPortMrrtStatus INTEGER

LldpXPnoRemEntry  
SEQUENCE    
  lldpXPnoRemLPDValue Unsigned32
  lldpXPnoRemPortTxDValue Unsigned32
  lldpXPnoRemPortRxDValue Unsigned32
  lldpXPnoRemPortStatusRT2 INTEGER
  lldpXPnoRemPortStatusRT3 INTEGER
  lldpXPnoRemPortNoS DisplayString
  lldpXPnoRemPortMrpUuId OCTET STRING
  lldpXPnoRemPortMrrtStatus INTEGER

Defined Values

lldpXPnoMIB 1.0.8802.1.1.2.1.5.3791
The LLDP Management Information Base extension module for PROFINET organizationally defined discovery information. Copyright (C) PROFIBUS Nutzerorganisation e.V. (2005).
MODULE-IDENTITY    

lldpXPnoObjects 1.0.8802.1.1.2.1.5.3791.1
OBJECT IDENTIFIER    

lldpXPnoConfig 1.0.8802.1.1.2.1.5.3791.1.1
OBJECT IDENTIFIER    

lldpXPnoLocalData 1.0.8802.1.1.2.1.5.3791.1.2
OBJECT IDENTIFIER    

lldpXPnoRemoteData 1.0.8802.1.1.2.1.5.3791.1.3
OBJECT IDENTIFIER    

lldpXPnoConfigTable 1.0.8802.1.1.2.1.5.3791.1.1.1
A table that controls selection of LLDP TLVs to be transmitted on individual ports.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LldpXPnoConfigEntry

lldpXPnoConfigEntry 1.0.8802.1.1.2.1.5.3791.1.1.1.1
LLDP configuration information that controls the transmission of PNO organizationally defined TLVs on LLDP transmission capable ports. This configuration object augments the lldpPortConfigEntry of the LLDP-MIB, therefore it is only present along with the port configuration defined by the associated lldpPortConfigEntry entry. Each active lldpXPnoConfigEntry must be restored from non-volatile storage (along with the corresponding lldpPortConfigEntry) after a re-initialization of the management system.
Status: current Access: not-accessible
OBJECT-TYPE    
  LldpXPnoConfigEntry  

lldpXPnoConfigSPDTxEnable 1.0.8802.1.1.2.1.5.3791.1.1.1.1.1
The lldpXPnoConfigSPDTxEnable, which is defined as a truth value and configured by the network management, determines whether the PNO organizationally defined signal propagation delay TLV transmission is allowed on a given LLDP transmission capable port. The signal propagation delay is composed of the port transmission delay, the port receiving delay and the line delay. These values can't be transmitted independently of each other. The value of this object must be restored from nonvolatile storage after a re-initialization of the management system.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

lldpXPnoConfigPortStatusTxEnable 1.0.8802.1.1.2.1.5.3791.1.1.1.1.2
The lldpXPnoConfigPortStatusTxEnable, which is defined as a truth value and configured by the network management, determines whether the PNO organizationally defined RT port status TLV transmission is allowed on a given LLDP transmission capable port. The value of this object must be restored from nonvolatile storage after a re-initialization of the management system.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

lldpXPnoConfigAliasTxEnable 1.0.8802.1.1.2.1.5.3791.1.1.1.1.3
The lldpXPnoConfigAliasTxEnable, which is defined as a truth value and configured by the network management, determines whether the PNO organizationally defined alias TLV (chassisId) transmission is allowed on a given LLDP transmission capable port. The value of this object must be restored from nonvolatile storage after a re-initialization of the management system.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

lldpXPnoConfigMrpTxEnable 1.0.8802.1.1.2.1.5.3791.1.1.1.1.4
The lldpXPnoConfigMrpTxEnable, which is defined as a truth value and configured by the network management, determines whether the PNO organizationally defined MRP TLV transmission is allowed on a given LLDP transmission capable port. The value of this object must be restored from nonvolatile storage after a re-initialization of the management system.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

lldpXPnoLocTable 1.0.8802.1.1.2.1.5.3791.1.2.1
This table contains one row per port for PNO organizationally defined LLDP extension on the local system known to this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LldpXPnoLocEntry

lldpXPnoLocEntry 1.0.8802.1.1.2.1.5.3791.1.2.1.1
Additional information about a particular port component. This object is indexed by the lldpLocPortNum of the LLDP-MIB, therefore it is only present along with the port entry defined by the associated lldpLocPortEntry entry. Each active lldpXPnoLocEntry must be restored from non-volatile storage (along with the corresponding lldpLocPortEntry) after a re-initialization of the management system.
Status: current Access: not-accessible
OBJECT-TYPE    
  LldpXPnoLocEntry  

lldpXPnoLocLPDValue 1.0.8802.1.1.2.1.5.3791.1.2.1.1.1
This integer value represents the line propagation delay in nanoseconds which was measured by the local system on the corresponding port. A value of zero shall be used if the system either could not accomplish the measurement or does not support such a measurement.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

lldpXPnoLocPortTxDValue 1.0.8802.1.1.2.1.5.3791.1.2.1.1.2
This integer value represents the PortTxDelay in nanoseconds which was measured by the local system on the corresponding port. A value of zero shall be used if the system either could not accomplish the measurement or does not support such a measurement.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

lldpXPnoLocPortRxDValue 1.0.8802.1.1.2.1.5.3791.1.2.1.1.3
This integer value represents the PortRxDelay in nanoseconds which was measured by the local system on the corresponding port. A value of zero shall be used if the system either could not accomplish the measurement or does not support such a measurement.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

lldpXPnoLocPortStatusRT2 1.0.8802.1.1.2.1.5.3791.1.2.1.1.4
This value represents the status of the corresponding port of the local system according to RT class 2. A value of off(0) means that there isn't any RT2 capability available for this port. When the port is configured for RT2 mode, but the mode isn't active yet the value will be configured(1). If the RT2 mode is configured for this port and the mode is active, the value will be running(2).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), configured(1), running(2)  

lldpXPnoLocPortStatusRT3 1.0.8802.1.1.2.1.5.3791.1.2.1.1.5
This value represents the status of the corresponding port of the local system according to RT class 3. A value of off(0) means that there isn't any RT3 capability available for this port. When the port is configured for RT3 mode, but the mode isn't active yet the value will be configured(1). When the port is ready for transmission and reception of RT3 traffic, the port status will be running(4).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), configured(1), up(2), down(3), running(4)  

lldpXPnoLocPortNoS 1.0.8802.1.1.2.1.5.3791.1.2.1.1.6
The local PROFINET NameofStation. If the station isn't configured yet, the value of this object will be the MAC address of the device as a string.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

lldpXPnoLocPortMrpUuId 1.0.8802.1.1.2.1.5.3791.1.2.1.1.7
The UUID of the MRP domain to which this port belongs to. If the port doesn't belong to a MRP domain, the value must be NIL ('0000000000000000').
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(16)  

lldpXPnoLocPortMrrtStatus 1.0.8802.1.1.2.1.5.3791.1.2.1.1.8
This object reports the status of the MRRT entity of the corresponding port. A value of off(0) means that there isn't any MRRT capability available for this port or it is switched off. The value configured(1) indicates that MRRT is configured for the port. When MRRT is active on the port, the value will be up(2).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), configured(1), up(2)  

lldpXPnoRemTable 1.0.8802.1.1.2.1.5.3791.1.3.1
This table contains one or more rows per physical network connection known to this agent. The agent may wish to ensure that only one lldpXPnoRemEntry is present for each local port, or it may choose to maintain multiple lldpXPnoRemEntries for the same local port.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LldpXPnoRemEntry

lldpXPnoRemEntry 1.0.8802.1.1.2.1.5.3791.1.3.1.1
Each entry represents the received information of the communication partner on this physical connection. The entries feature multiple indices from the lldpRemEntry of the LLDP-MIB, therefore it is only present along with the description defined by the associated lldpRemEntry entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  LldpXPnoRemEntry  

lldpXPnoRemLPDValue 1.0.8802.1.1.2.1.5.3791.1.3.1.1.1
This integer value represents the line propagation delay in nanoseconds which was measured by the remote system on the corresponding port. A value of zero shall be used if the remote system either could not accomplish the measurement or does not support such a measurement.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

lldpXPnoRemPortTxDValue 1.0.8802.1.1.2.1.5.3791.1.3.1.1.2
This integer value represents the PortTxDelay in nanoseconds which was measured by the remote system on the corresponding port. A value of zero shall be used if the remote system either could not accomplish the measurement or does not support such a measurement.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

lldpXPnoRemPortRxDValue 1.0.8802.1.1.2.1.5.3791.1.3.1.1.3
This integer value represents the PortRxDelay in nanoseconds which was measured by the remote system on the corresponding port. A value of zero shall be used if the remote system either could not accomplish the measurement or does not support such a measurement.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

lldpXPnoRemPortStatusRT2 1.0.8802.1.1.2.1.5.3791.1.3.1.1.4
This value represents the status of the corresponding port of the remote system according to RT class 2. A value of off(0) means that there isn't any RT2 capability available for this port. When the port is configured for RT2 mode, but the mode isn't active yet the value will be configured(1). If the RT2 mode is configured for this port and the mode is active, the value will be running(2).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), configured(1), running(2)  

lldpXPnoRemPortStatusRT3 1.0.8802.1.1.2.1.5.3791.1.3.1.1.5
This value represents the status of the corresponding port of the remote system according to RT class 3. A value of off(0) means that there isn't any RT3 capability available for this port. When the port is configured for RT3 mode, but the mode isn't active yet the value will be configured(1). When the port is ready for transmission and reception of RT3 traffic, the port status will be running(4).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), configured(1), up(2), down(3), running(4)  

lldpXPnoRemPortNoS 1.0.8802.1.1.2.1.5.3791.1.3.1.1.6
The PROFINET NameofStation of the remote partner. If the station isn't configured yet, the value of this object will be the MAC address of the device as a string.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

lldpXPnoRemPortMrpUuId 1.0.8802.1.1.2.1.5.3791.1.3.1.1.7
The UUID of the MRP domain to which the corresponding port of the remote system belongs to. If the port doesn't belong to a MRP domain, the value must be NIL ('0000000000000000').
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(16)  

lldpXPnoRemPortMrrtStatus 1.0.8802.1.1.2.1.5.3791.1.3.1.1.8
This object reports the status of the MRRT entity of the corresponding port. A value of off(0) means that there isn't any MRRT capability available for this port or it is switched off. The value configured(1) indicates that MRRT is configured for the port. When MRRT is active on the port, the value will be up(2).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), configured(1), up(2)  

lldpXPnoConformance 1.0.8802.1.1.2.1.5.3791.2
OBJECT IDENTIFIER    

lldpXPnoCompliances 1.0.8802.1.1.2.1.5.3791.2.1
OBJECT IDENTIFIER    

lldpXPnoGroups 1.0.8802.1.1.2.1.5.3791.2.2
OBJECT IDENTIFIER    

lldpXPnoCompliance 1.0.8802.1.1.2.1.5.3791.2.1.1
The compliance statement for SNMP entities which implement the PNO organizationally defined LLDP extension MIB.
Status: current Access: read-only
MODULE-COMPLIANCE    

lldpXPnoConfigGroup 1.0.8802.1.1.2.1.5.3791.2.2.1
The collection of objects which are used to configure the PNO organizationally defined LLDP extension implementation behavior. This group is mandatory for agents which implement the PNO organizationally defined LLDP extension, because the information about the signal propagation delay is necessary to configure PROFINET domains.
Status: current Access: read-only
OBJECT-GROUP    

lldpXPnoLocGroup 1.0.8802.1.1.2.1.5.3791.2.2.2
The collection of objects which are used to configure the PNO organizationally defined LLDP extension implementation behavior. This group is mandatory for agents which implement the PNO organizationally defined LLDP extension, because the information about the signal propagation delay is necessary to configure PROFINET domains.
Status: current Access: read-only
OBJECT-GROUP    

lldpXPnoRemGroup 1.0.8802.1.1.2.1.5.3791.2.2.3
The collection of objects which are used to configure the PNO organizationally defined LLDP extension implementation behavior. This group is mandatory for agents which implement the PNO organizationally defined LLDP extension, because the information about the signal propagation delay is necessary to configure PROFINET domains.
Status: current Access: read-only
OBJECT-GROUP    

lldpXPnoMRPGroup 1.0.8802.1.1.2.1.5.3791.2.2.4
The collection of objects which are used to configure the PNO organizationally defined LLDP extension implementation behavior. This group is mandatory for agents which implement the PNO organizationally defined LLDP extension, because the information about the signal propagation delay is necessary to configure PROFINET domains.
Status: current Access: read-only
OBJECT-GROUP