IMCO-LS110-MIB

File: IMCO-LS110-MIB.mib (9524 bytes)

Imported modules

SNMPv2-SMI RFC-1215

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Counter32
Integer32 Gauge32 TimeTicks
IpAddress enterprises TRAP-TYPE

Defined Values

mib-AN-Dcz-SDS 1.3.6.1.4.1.33283
The MIB module to describe PSMSmicro version of SDS.
MODULE-IDENTITY    

sdsxpublic 1.3.6.1.4.1.33283.1
OBJECT IDENTIFIER    

sdsBIGandSTSW 1.3.6.1.4.1.33283.1.30
OBJECT IDENTIFIER    

sdsOptoInput 1.3.6.1.4.1.33283.1.30.2
OBJECT IDENTIFIER    

opto1 1.3.6.1.4.1.33283.1.30.2.1
Current OPTO1 binary input status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER activeSignalPresent(0), noSignal(32768)  

opto2 1.3.6.1.4.1.33283.1.30.2.2
Current OPTO2 binary input status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER activeSignalPresent(0), noSignal(1)  

opto3 1.3.6.1.4.1.33283.1.30.2.3
Current Mains (OPTO3) binary input status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER activeSignalPresent(0), noSignal(2)  

sdsOutputRelays 1.3.6.1.4.1.33283.1.30.3
OBJECT IDENTIFIER    

sdsOutputRelay1 1.3.6.1.4.1.33283.1.30.3.1
OBJECT IDENTIFIER    

sdsRE1state 1.3.6.1.4.1.33283.1.30.3.1.1
Current RELAY 1 output status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), activated(255)  

sdsOutputRelay2 1.3.6.1.4.1.33283.1.30.3.2
OBJECT IDENTIFIER    

sdsRE2state 1.3.6.1.4.1.33283.1.30.3.2.1
Current RELAY 2 output status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), activated(255)  

sdsOutputRelay3 1.3.6.1.4.1.33283.1.30.3.3
OBJECT IDENTIFIER    

sdsRE3state 1.3.6.1.4.1.33283.1.30.3.3.1
Current RELAY 3 output status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), activated(255)  

sdsADCinputs 1.3.6.1.4.1.33283.1.30.5
OBJECT IDENTIFIER    

sdsADCitem0 1.3.6.1.4.1.33283.1.30.5.1
OBJECT IDENTIFIER    

sdsTempSensValue 1.3.6.1.4.1.33283.1.30.5.1.3
Temperature Sensor (C) multiplied by 100.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

sdsTempSensName 1.3.6.1.4.1.33283.1.30.5.1.4
User name for the analog temperature sensor.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sdsADCvalues 1.3.6.1.4.1.33283.1.30.7
OBJECT IDENTIFIER    

sdsMaximumLoad 1.3.6.1.4.1.33283.1.30.7.2
Maximum Load (W) multiplied by 10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sdsAlarmText 1.3.6.1.4.1.33283.1.30.7.3
SDS Alarm Text.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sdsOutputVoltage1 1.3.6.1.4.1.33283.1.30.7.4
Output voltage U1 (V) multiplied by 100.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sdsOutputVoltage2 1.3.6.1.4.1.33283.1.30.7.5
Output voltage U2 (V) multiplied by 100.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sdsOutputCurrent 1.3.6.1.4.1.33283.1.30.7.6
Output current I (A) multiplied by 10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sdsBatteryCapacity 1.3.6.1.4.1.33283.1.30.7.7
Battery Capacity (%) multiplied by 10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sdsLoad 1.3.6.1.4.1.33283.1.30.7.8
Load (%) multiplied by 10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sdsCapTestTime 1.3.6.1.4.1.33283.1.30.7.9
Time (min) of last Capacity Test.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sdsGeneralInfoEntry 1.3.6.1.4.1.33283.1.30.8
OBJECT IDENTIFIER    

sdsManufacturer 1.3.6.1.4.1.33283.1.30.8.80
Manufacturer of the device.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sdsModel 1.3.6.1.4.1.33283.1.30.8.81
Model (type) of the device.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sdsName 1.3.6.1.4.1.33283.1.30.8.82
Name/Location of the device.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sdsSerialNumber 1.3.6.1.4.1.33283.1.30.8.83
Serial number of the device.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sdsSoftware 1.3.6.1.4.1.33283.1.30.8.84
Software version of the device.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

opto1-trap 100
TRAP: optical input 1 status.
TRAP-TYPE    

opto2-trap 101
TRAP: optical input 2 status.
TRAP-TYPE    

opto3-trap 102
TRAP: optical input 3 status.
TRAP-TYPE    

sdsRE1state-trap 150
TRAP: Current RELAY 1 output status.
TRAP-TYPE    

sdsRE2state-trap 153
TRAP: Current RELAY 2 output status.
TRAP-TYPE    

sdsTempSensValue-trap 222
TRAP: Temperature Sensor (C) multiplied by 100.
TRAP-TYPE    

sdsTempSensName-trap 223
TRAP: User name for analog temperature sensor.
TRAP-TYPE    

sdsMaximumLoad-trap 401
TRAP: SDS Maximum Load-trap.
TRAP-TYPE    

sdsAlarmText-trap 402
TRAP: SDS Alarm Text.
TRAP-TYPE    

sdsOutputVoltage1-trap 403
TRAP: SDS Output Voltage1-trap.
TRAP-TYPE    

sdsOutputVoltage2-trap 404
TRAP: SDS Outpur Voltage2-trap.
TRAP-TYPE    

sdsOutputCurrent-trap 405
TRAP: SDS Output current-trap.
TRAP-TYPE    

sdsBatteryCapacity-trap 406
TRAP: SDS Battery Capacity-trap.
TRAP-TYPE    

sdsLoad-trap 407
TRAP: SDS Load-trap.
TRAP-TYPE    

sdsCapTestTime-trap 408
TRAP: SDS CapTestTime-trap.
TRAP-TYPE