IBOOTPDU-MIB

File: IBOOTPDU-MIB.mib (12597 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC

Imported symbols

NOTIFICATION-TYPE OBJECT-TYPE MODULE-IDENTITY
enterprises IpAddress Integer32
TEXTUAL-CONVENTION MacAddress DisplayString

Defined Types

TC1  
Tok_String
TEXTUAL-CONVENTION    
  Integer32  

SnmpManagerEntry  
SEQUENCE    
  snmpManagerIndex Integer32
  snmpManagerAddress DisplayString
  snmpManagerName DisplayString
  snmpTrapCommunity DisplayString

OutletEntry  
SEQUENCE    
  outletIndex Integer32
  outletName DisplayString
  outletInitialState INTEGER
  outletCycleTime Integer32
  outletControl INTEGER
  outletStatus INTEGER
  outletActualStatus INTEGER

Defined Values

iBoot-PDU-Agent 1.3.6.1.4.1.1418.6
iBoot-PDU Agent Version 1.1
MODULE-IDENTITY    

dataprobe 1.3.6.1.4.1.1418
OBJECT IDENTIFIER    

device 1.3.6.1.4.1.1418.6.1
OBJECT IDENTIFIER    

console 1.3.6.1.4.1.1418.6.2
OBJECT IDENTIFIER    

network 1.3.6.1.4.1.1418.6.3
OBJECT IDENTIFIER    

snmp 1.3.6.1.4.1.1418.6.4
OBJECT IDENTIFIER    

sensors 1.3.6.1.4.1.1418.6.6
OBJECT IDENTIFIER    

notifications 1.3.6.1.4.1.1418.6.7
OBJECT IDENTIFIER    

firmwareVersion 1.3.6.1.4.1.1418.6.1.1
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

deviceName 1.3.6.1.4.1.1418.6.1.2
This is a 20 character string that contains the name of the iBootBar.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

deviceFamily 1.3.6.1.4.1.1418.6.1.3
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

deviceModelName 1.3.6.1.4.1.1418.6.1.4
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

deviceConnector 1.3.6.1.4.1.1418.6.1.5
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nema(0), iec(1)  

deviceNumberOfOutlets 1.3.6.1.4.1.1418.6.1.6
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

deviceNumberOfLineCords 1.3.6.1.4.1.1418.6.1.7
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER one(0), two(1)  

deviceMaxCurrent 1.3.6.1.4.1.1418.6.1.8
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

deviceTemperatureUnit 1.3.6.1.4.1.1418.6.1.9
fahrenheit (0) celsius (1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fahrenheit(0), celsius(1)  

deviceTimeZone 1.3.6.1.4.1.1418.6.1.10
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

deviceCalibrated 1.3.6.1.4.1.1418.6.1.11
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

modemCountryCode 1.3.6.1.4.1.1418.6.1.12
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

outletDelayTime 1.3.6.1.4.1.1418.6.1.13
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

cloudServiceEnabled 1.3.6.1.4.1.1418.6.1.14
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(0), true(1)  

cloudServerAddress 1.3.6.1.4.1.1418.6.1.15
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(128)  

cloudActivationCode 1.3.6.1.4.1.1418.6.1.16
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cloudUUID 1.3.6.1.4.1.1418.6.1.17
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

setFactoryDefaults 1.3.6.1.4.1.1418.6.1.18
true(1) false(0)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(0), true(1)  

rebootSystem 1.3.6.1.4.1.1418.6.1.19
true(1) false(0)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(0), true(1)  

rebootRequired 1.3.6.1.4.1.1418.6.1.20
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

serialPortEnabled 1.3.6.1.4.1.1418.6.2.1
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(0), true(1)  

consoleTimeout 1.3.6.1.4.1.1418.6.2.2
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..60  

telnetEnabled 1.3.6.1.4.1.1418.6.2.3
Eanlbe the telnet server.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(0), true(1)  

telnetPort 1.3.6.1.4.1.1418.6.2.4
The port for the telnet server to use.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..65535  

sshEnabled 1.3.6.1.4.1.1418.6.2.5
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(0), true(1)  

sshPort 1.3.6.1.4.1.1418.6.2.6
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..65535  

macAddress 1.3.6.1.4.1.1418.6.3.1
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

ipMode 1.3.6.1.4.1.1418.6.3.2
static(0) dhcp(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER static(0), dhcp(1)  

ipAddress 1.3.6.1.4.1.1418.6.3.3
The IP Address of the device
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

subnetMask 1.3.6.1.4.1.1418.6.3.4
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

gateway 1.3.6.1.4.1.1418.6.3.5
Address of the default gateway
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

dnsServer1 1.3.6.1.4.1.1418.6.3.6
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

dnsServer2 1.3.6.1.4.1.1418.6.3.7
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

sslEnabled 1.3.6.1.4.1.1418.6.3.8
Enable secure sockest layer on the web server.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(0), true(1)  

sslPort 1.3.6.1.4.1.1418.6.3.9
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..65535  

webEnabled 1.3.6.1.4.1.1418.6.3.10
Use this variable to enable/disable the web server
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(0), true(1)  

webPort 1.3.6.1.4.1.1418.6.3.11
The port number that the web server will use. Changing this var will not take effect until the unit has be reset.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

snmpEnabled 1.3.6.1.4.1.1418.6.4.1
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(0), true(1)  

snmpReadCommunity 1.3.6.1.4.1.1418.6.4.2
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

snmpWriteCommunity 1.3.6.1.4.1.1418.6.4.3
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

snmpManagerTable 1.3.6.1.4.1.1418.6.4.4
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SnmpManagerEntry

snmpManagerEntry 1.3.6.1.4.1.1418.6.4.4.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SnmpManagerEntry  

snmpManagerIndex 1.3.6.1.4.1.1418.6.4.4.1.1
The table index
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

snmpManagerAddress 1.3.6.1.4.1.1418.6.4.4.1.2
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(16)  

snmpManagerName 1.3.6.1.4.1.1418.6.4.4.1.3
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

snmpTrapCommunity 1.3.6.1.4.1.1418.6.4.4.1.4
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

outletTable 1.3.6.1.4.1.1418.6.5
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OutletEntry

outletEntry 1.3.6.1.4.1.1418.6.5.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  OutletEntry  

outletIndex 1.3.6.1.4.1.1418.6.5.1.1
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..64  

outletName 1.3.6.1.4.1.1418.6.5.1.2
The name of the outlet up to 20 characters
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

outletInitialState 1.3.6.1.4.1.1418.6.5.1.3
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1), last(2)  

outletCycleTime 1.3.6.1.4.1.1418.6.5.1.4
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

outletControl 1.3.6.1.4.1.1418.6.5.1.5
Use this a a write only variable. It is used to change the outlets status
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1), cycle(2)  

outletStatus 1.3.6.1.4.1.1418.6.5.1.6
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1), cycle(2), reboot(3), pend-on(4)  

outletActualStatus 1.3.6.1.4.1.1418.6.5.1.7
Status of the physical outlet
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

voltageLC1 1.3.6.1.4.1.1418.6.6.1
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

currentLC1 1.3.6.1.4.1.1418.6.6.2
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

voltageLC2 1.3.6.1.4.1.1418.6.6.3
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

currentLC2 1.3.6.1.4.1.1418.6.6.4
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

temperature1 1.3.6.1.4.1.1418.6.6.5
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

temperature2 1.3.6.1.4.1.1418.6.6.6
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

outletChange 1.3.6.1.4.1.1418.6.7.1
This trap is sent when ever an outlet changes state. It contains the name of the outlet.
Status: current Access: read-only
NOTIFICATION-TYPE