HWMUSA-SIGTRAN-MIB

File: HWMUSA-SIGTRAN-MIB.mib (75045 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
HUAWEI-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
private MODULE-COMPLIANCE OBJECT-GROUP
NOTIFICATION-GROUP TEXTUAL-CONVENTION RowStatus
DateAndTime DisplayString IpAddress
Integer32 Unsigned32 ias

Defined Types

HwL2uaLinkSetMngtEntry  
SEQUENCE    
  hwL2uaLinkSetNo Integer32
  hwL2uaLinkSetProtocolType INTEGER
  hwL2uaLinkSetPendingTime Integer32
  hwL2uaLinkSetTrafficMode INTEGER
  hwL2uaLinkSetCSMode INTEGER
  hwL2uaLinkSetIIDType INTEGER
  hwL2uaLinkSetLinkNum Integer32
  hwL2uaLinkSetOperState INTEGER
  hwL2uaLinkSetRowStatus RowStatus
  hwL2uaLinkSetMgId Integer32
  hwL2uaLinkSetIidMap Integer32
  hwL2uaLinkSetJointlyWork INTEGER
  hwL2uaLinkSetIidPrefix OCTET STRING
  hwL2uaLinkSetIidBraPrefix OCTET STRING
  hwL2uaLinkSetIidBraSuffix OCTET STRING
  hwL2uaLinkSetIidPraPrefix OCTET STRING
  hwL2uaLinkSetIidPrasuffix OCTET STRING

HwL2uaLinkMngtEntry  
SEQUENCE    
  hwL2uaLinkNo Integer32
  hwL2uaLinkLinkSetNo Integer32
  hwL2uaLinkLocalPort Integer32
  hwL2uaLinkLocalIpaddr IpAddress
  hwL2uaLinkRemotePort Integer32
  hwL2uaLinkRemoteIpaddr1 IpAddress
  hwL2uaLinkRemoteIpaddr2 IpAddress
  hwL2uaLinkMaxInStreamNum Integer32
  hwL2uaLinkMaxOutStreamNum Integer32
  hwL2uaLinkActiveStandbyFlag INTEGER
  hwL2uaLinkLockFlag INTEGER
  hwL2uaLinkUsedInStreamNum Integer32
  hwL2uaLinkUsedOutStreamNum Integer32
  hwL2uaLinkSctpAssocId Integer32
  hwL2uaLinkOperState INTEGER
  hwL2uaLinkCongestState INTEGER
  hwL2uaLinkMaintainOper INTEGER
  hwL2uaLinkRowStatus RowStatus
  hwL2uaLinkWithMedGwyCtrlIdx Integer32
  hwL2uaLinkPriority Integer32
  hwL2uaLinkLockStatus INTEGER
  hwL2uaLinkLocalIpaddrDhcpClientIndex Integer32
  hwL2uaLinkLocalIpDnyAddrName OCTET STRING

HwSctpAssocStatEntry  
SEQUENCE    
  hwSctpAssocStatAssocId Integer32
  hwSctpAssocStatT1Expired Integer32
  hwSctpAssocStatT2Expired Integer32
  hwSctpAssocStatRetransChunks Integer32
  hwSctpAssocStatSendDataChunks Integer32
  hwSctpAssocStatRevDataChunks Integer32
  hwSctpAssocStatRecPackets Integer32
  hwSctpAssocStatRecErrPackets Integer32
  hwSctpAssocStatOperStatus INTEGER
  hwSctpAssocStatSentSctpPackets Integer32

HwSctpAssocInfoEntry  
SEQUENCE    
  hwSctpAssocId Integer32
  hwSctpAssocState INTEGER
  hwSctpAssocType INTEGER
  hwSctpAssocApplId Integer32
  hwSctpAssocLocalPort Integer32
  hwSctpAssocRemotePort Integer32
  hwSctpAssocLocalIPaddr IpAddress
  hwSctpAssocRemoteIPaddr IpAddress
  hwSctpAssocAllowHB INTEGER
  hwSctpAssocLocalRwnd Unsigned32
  hwSctpAssocRemoteRwnd Unsigned32
  hwSctpAssocUnfirmDataChunks Integer32
  hwSctpAssocRemoteIP1addr IpAddress
  hwSctpAssocRemoteIP1State INTEGER
  hwSctpAssocRemoteIP1WaitAck Integer32
  hwSctpAssocRemoteIP1Cwnd Integer32
  hwSctpAssocRemoteIP1Unfirm Integer32
  hwSctpAssocRemoteIP1Rto Integer32
  hwSctpAssocRemoteIP1Srtt Integer32
  hwSctpAssocRemoteIP1Rttvar Integer32
  hwSctpAssocRemoteIP1AllowHB INTEGER
  hwSctpAssocRemoteIP2addr IpAddress
  hwSctpAssocRemoteIP2State INTEGER
  hwSctpAssocRemoteIP2WaitAck Integer32
  hwSctpAssocRemoteIP2Cwnd Integer32
  hwSctpAssocRemoteIP2Unfirm Integer32
  hwSctpAssocRemoteIP2Rto Integer32
  hwSctpAssocRemoteIP2Srtt Integer32
  hwSctpAssocRemoteIP2Rttvar Integer32
  hwSctpAssocRemoteIP2AllowHB INTEGER

HwIsdnIuaDuaErrStatsThresholdCfgEntry  
SEQUENCE    
  hwIsdnIuaDuaErrLinkNoIndex Integer32
  hwIsdnIuaProtocolErrAlarmThreshold Integer32
  hwIsdnDuaProtocolErrAlarmThreshold Integer32

HwMifSctpCfgParaEntry  
SEQUENCE    
  hwMifSctpCfgParaProtoType Integer32
  hwMifSctpCfgParaInterfaceId Integer32
  hwMifSctpCfgParaMaxInStreamNum Integer32
  hwMifSctpCfgParaMaxOutStreamNum Integer32
  hwMifSctpCfgParaRtoMin Integer32
  hwMifSctpCfgParaRtoMax Integer32
  hwMifSctpCfgParaRtoInit Integer32
  hwMifSctpCfgParaValidCookieLife Integer32
  hwMifSctpCfgParaMaxInitRetrans Integer32
  hwMifSctpCfgParaRtoAlpha Integer32
  hwMifSctpCfgParaRtoBeta Integer32
  hwMifSctpCfgParaAssocMaxRetrans Integer32
  hwMifSctpCfgParaPathMaxRetrans Integer32
  hwMifSctpCfgParaNoCongestionLevel Integer32
  hwMifSctpCfgParaLowCongestionLevel Integer32
  hwMifSctpCfgParaHighCongestionLevel Integer32
  hwMifSctpCfgParaHbInterval Integer32
  hwMifSctpCfgParaSendChecksum INTEGER
  hwMifSctpCfgParaRecvChecksum INTEGER
  hwMifSctpCfgParaChecksumArith INTEGER

HwMifSctpRunningParaEntry  
SEQUENCE    
  hwMifSctpRunningParaProtoType Integer32
  hwMifSctpRunningParaInterfaceId Integer32
  hwMifSctpRunningParaMaxInStreamNum Integer32
  hwMifSctpRunningParaMaxOutStreamNum Integer32
  hwMifSctpRunningParaRtoMin Integer32
  hwMifSctpRunningParaRtoMax Integer32
  hwMifSctpRunningParaRtoInit Integer32
  hwMifSctpRunningParaValidCookieLife Integer32
  hwMifSctpRunningParaMaxInitRetrans Integer32
  hwMifSctpRunningParaRtoAlpha Integer32
  hwMifSctpRunningParaRtoBeta Integer32
  hwMifSctpRunningParaAssocMaxRetrans Integer32
  hwMifSctpRunningParaPathMaxRetrans Integer32
  hwMifSctpRunningParaNoCongestionLevel Integer32
  hwMifSctpRunningParaLowCongestionLevel Integer32
  hwMifSctpRunningParaHighCongestionLevel Integer32
  hwMifSctpRunningParaHbInterval Integer32
  hwMifSctpRunningParaSendChecksum INTEGER
  hwMifSctpRunningParaRecvChecksum INTEGER
  hwMifSctpRunningParaChecksumArith INTEGER

Defined Values

hwIASSigtranObjects 1.3.6.1.4.1.2011.2.6.7.6.1
This MIB module defines MIB objects which provides SIGTRAN management.
MODULE-IDENTITY    

hwIASSigtranTrapsVbOids 1.3.6.1.4.1.2011.2.6.7.6.2
OBJECT IDENTIFIER    

hwIASSigtranTraps 1.3.6.1.4.1.2011.2.6.7.6.3
OBJECT IDENTIFIER    

hwIASSigtranCommonTraps 1.3.6.1.4.1.2011.2.6.7.6.3.1
OBJECT IDENTIFIER    

hwIASSigtranAlarmTraps 1.3.6.1.4.1.2011.2.6.7.6.3.2
OBJECT IDENTIFIER    

hwIASSigtranL2uaTraps 1.3.6.1.4.1.2011.2.6.7.6.3.1.1
OBJECT IDENTIFIER    

hwIASSigtranL2uaAlarmTraps 1.3.6.1.4.1.2011.2.6.7.6.3.2.1
OBJECT IDENTIFIER    

hwSctpVersionTable 1.3.6.1.4.1.2011.2.6.7.6.1.11
OBJECT IDENTIFIER    

hwL2uaVersionTable 1.3.6.1.4.1.2011.2.6.7.6.1.10
OBJECT IDENTIFIER    

hwSctpParaTable 1.3.6.1.4.1.2011.2.6.7.6.1.9
OBJECT IDENTIFIER    

hwSctpGlobalStatTable 1.3.6.1.4.1.2011.2.6.7.6.1.8
OBJECT IDENTIFIER    

hwIASSigtran 1.3.6.1.4.1.2011.2.6.7.6
OBJECT IDENTIFIER    

hwL2uaLinkSetMngtTable 1.3.6.1.4.1.2011.2.6.7.6.1.1
This table is used to config L2UA linkset. The index of this table is hwL2uaLinkSetNo.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwL2uaLinkSetMngtEntry

hwL2uaLinkSetMngtEntry 1.3.6.1.4.1.2011.2.6.7.6.1.1.1
This table is used to config L2UA linkset. The index of this entry is hwL2uaLinkSetNo.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwL2uaLinkSetMngtEntry  

hwL2uaLinkSetNo 1.3.6.1.4.1.2011.2.6.7.6.1.1.1.1
The link set number
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..15  

hwL2uaLinkSetProtocolType 1.3.6.1.4.1.2011.2.6.7.6.1.1.1.2
Protocol type. Options: 1. iua(1) -indicates that the Protocol type is IUA 2. m2ua(2) -indicates that that the Protocol type is M2UA 3. v5ua(5) -indicates that that the Protocol type is V5UA(currently, only IUA is supported.)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER iua(1), m2ua(2), v5ua(5)  

hwL2uaLinkSetPendingTime 1.3.6.1.4.1.2011.2.6.7.6.1.1.1.3
The pending time of the link set (the last active link in the link set switches to another state. During the pending time length, if no link in the link set switches to the active state, the link set enters the inactive or down state.). Default: 4 Unit: second
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..100  

hwL2uaLinkSetTrafficMode 1.3.6.1.4.1.2011.2.6.7.6.1.1.1.4
The working mode of the link set. Options: 1. override(1) -indicates that the working mode of the link set is override 2. loadshare(2) -indicates that the working mode of the link set is loadshare
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER override(1), loadshare(2)  

hwL2uaLinkSetCSMode 1.3.6.1.4.1.2011.2.6.7.6.1.1.1.5
C/S mode of the link set. Options: 1. client(1) -indicates that the C/S mode of the link set is Client 2. server(2) -indicates that the C/S mode of the link set is Server Default: 2
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER client(1), server(2)  

hwL2uaLinkSetIIDType 1.3.6.1.4.1.2011.2.6.7.6.1.1.1.6
Type of the interface ID. Options: 1. integer(1) -integer 2. text(2) -text
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER integer(1), text(2)  

hwL2uaLinkSetLinkNum 1.3.6.1.4.1.2011.2.6.7.6.1.1.1.7
The number of links in the link set
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwL2uaLinkSetOperState 1.3.6.1.4.1.2011.2.6.7.6.1.1.1.8
Status of the link set. Options: 1. down(1) -indicates that the Status of the link set is down 2. inactive(2) -indicates that the Status of the link set is inactive 3. active(3) -indicates that the Status of the link set is active 4. pending(4) -indicates that the Status of the link set is pending
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER down(1), inactive(2), active(3), pending(4)  

hwL2uaLinkSetRowStatus 1.3.6.1.4.1.2011.2.6.7.6.1.1.1.9
Row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

hwL2uaLinkSetMgId 1.3.6.1.4.1.2011.2.6.7.6.1.1.1.10
MG interface ID. -1 means this parameter is not configured.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1 | 0..16777215  

hwL2uaLinkSetIidMap 1.3.6.1.4.1.2011.2.6.7.6.1.1.1.11
InterfaceID generation mode. 1:generated by user input,use format:interfaceID 2:generated automatically,use format:ffsspp, ff-shelf number,ss-slot number, pp-port number, decimal number 3:generated automatically,use format:rrrrfffffssssspppppppxxxxxxxxxxx ,rrrr-rack, fffff-shelf number,sssss-slot number, ppppppp-port number,xxxxxxxxxxx-reserved,binary number 4:generated automatically,FT text format:prefix+ff/ss/pp, ff-shelf number,ss-slot number, pp-port number, text 5:generated by user input,use format:braprefix+interfaceID+brasuffix or praprefix+interfaceID+prasuffix, the length of praprefix+interfaceID+prasuffix must be shorter than 31 Default:1
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..5  

hwL2uaLinkSetJointlyWork 1.3.6.1.4.1.2011.2.6.7.6.1.1.1.12
IUA link joint work with MGC. Options: 1.enable(1) -support IUA Link joint work with MGC 2.disable(2) -not support IUA Link joint work with MGC It must config together with hwL2uaLinkSetMgId.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hwL2uaLinkSetIidPrefix 1.3.6.1.4.1.2011.2.6.7.6.1.1.1.13
Indicates the prefix of IID.The prefix is not allowed to contain the character:';'':'','
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

hwL2uaLinkSetIidBraPrefix 1.3.6.1.4.1.2011.2.6.7.6.1.1.1.14
Indicates the bra prefix of IID.The prefix is not allowed to contain the character:';'':'','
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

hwL2uaLinkSetIidBraSuffix 1.3.6.1.4.1.2011.2.6.7.6.1.1.1.15
Indicates the bra suffix of IID.The suffix is not allowed to contain the character:';'':'','
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

hwL2uaLinkSetIidPraPrefix 1.3.6.1.4.1.2011.2.6.7.6.1.1.1.16
Indicates the pra prefix of IID.The prefix is not allowed to contain the character:';'':'','
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

hwL2uaLinkSetIidPrasuffix 1.3.6.1.4.1.2011.2.6.7.6.1.1.1.17
Indicates the pra suffix of IID.The suffix is not allowed to contain the character:';'':'','
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

hwL2uaLinkMngtTable 1.3.6.1.4.1.2011.2.6.7.6.1.2
This table is used to config L2UA link. The index of this table is hwL2uaLinkNo.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwL2uaLinkMngtEntry

hwL2uaLinkMngtEntry 1.3.6.1.4.1.2011.2.6.7.6.1.2.1
This table is used to config L2UA link. The index of this entry is hwL2uaLinkNo.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwL2uaLinkMngtEntry  

hwL2uaLinkNo 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.1
Link No.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..15  

hwL2uaLinkLinkSetNo 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.2
Link set No.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..15  

hwL2uaLinkLocalPort 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.3
Local port number
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..65534  

hwL2uaLinkLocalIpaddr 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.4
Local IP address
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

hwL2uaLinkRemotePort 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.5
Remote port number
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..65534  

hwL2uaLinkRemoteIpaddr1 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.6
Remote IP address 1
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

hwL2uaLinkRemoteIpaddr2 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.7
Remote IP address 2
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

hwL2uaLinkMaxInStreamNum 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.8
Maximum number of inbound streams. -1 means the IUA link is configurated with DHCP but the vlan IP isn't gained by DHCP.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1 | 2..1025  

hwL2uaLinkMaxOutStreamNum 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.9
Maximum number of outbound streams. -1 means the IUA link is configurated with DHCP but the vlan IP isn't gained by DHCP.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1 | 2..1025  

hwL2uaLinkActiveStandbyFlag 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.10
Active and standby flag. Options: 1. active(1)-indicates that the Active and standby flag is active 2. standby(2)-indicates that the Active and standby flag is standby 3. null(-1)-indicates that the Active and standby flag is invalid Display -1 when the vlanid can't get Local IP in dhcp mode.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), standby(2), null(-1)  

hwL2uaLinkLockFlag 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.11
IUA Link maintenance lock flag. Options: 1. lock(1)-indicates that the IUA Link maintenance lock flag is active 2. unlock(2)-indicates that the IUA Link maintenance lock flag is standby
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER lock(1), unlock(2)  

hwL2uaLinkUsedInStreamNum 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.12
Number of inbound streams used currently -1 indicates that the number is invalid
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1 | 0..1024  

hwL2uaLinkUsedOutStreamNum 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.13
Number of outbound streams used currently -1 indicates that the number is invalid
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1 | 0..1024  

hwL2uaLinkSctpAssocId 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.14
SCTP association ID that the L2UA link corresponds to -1 means there is no SCTP association.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1 | 1..16  

hwL2uaLinkOperState 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.15
Link status. Options: 1. unestablish(1)-indicates that the Link status is active 2. establish(2)-indicates that the Link status is standby 3. inactive(3)-indicates that the Link status is inactive 4. active(4)-indicates that the Link status is active
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unestablish(1), establish(2), inactive(3), active(4)  

hwL2uaLinkCongestState 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.16
Congestion state. Options: 1. uncongest(1) -not congested 2. congest(2) -congested 3. null(-1) -null Display -1 when the vlanid can't get Local IP in dhcp mode.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER uncongest(1), congest(2), null(-1)  

hwL2uaLinkMaintainOper 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.17
Link maintenance operation. Options: 1. lock(1) -indicates that the link maintenance operation is Lock 2. unlock(2) -indicates that the link maintenance operation is Unlock 3. reset(3) -indicates that the link status is Reset 4. null(-1) -indicates that the link maintenance operation is invalid
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER lock(1), unlock(2), reset(3), null(-1)  

hwL2uaLinkRowStatus 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.18
Row status
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

hwL2uaLinkWithMedGwyCtrlIdx 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.19
Config IUA Link jiont work with witch MGC. 0: Primary MGC. 1: Secondary MGC. -1 means this parameter is not configed.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1 | 0..1  

hwL2uaLinkPriority 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.20
Is available when the working mode of the link set is Load-share. In Over ride mode, this parameter can be read, but no use. Default:0
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..15  

hwL2uaLinkLockStatus 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.21
IUA Link current Lock State: Options: 1. unlock(1)-indicates that the Current IUA Link not locked 2. servicelock(2)-indicates that the Current IUA Link was locked for joint work with MGC 3. maintenancelock(3)-indicates that the Current IUA Link was locked by maintenance operation Adminlock have pripority over autolock. 4. display -1 when the vlanid can't get Local IP in dhcp mode.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unlock(1), servicelock(2), maintenancelock(3), null(-1)  

hwL2uaLinkLocalIpaddrDhcpClientIndex 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.22
Dhcp L2ua vlan id. The valid value is 1..4093,if the value is -1, the static signal ip will be used.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4093 | -1  

hwL2uaLinkLocalIpDnyAddrName 1.3.6.1.4.1.2011.2.6.7.6.1.2.1.23
Dynamic local IP name.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwSctpAssocStatTable 1.3.6.1.4.1.2011.2.6.7.6.1.7
This table is used to query statistic of a SCTP association. The index of this table is hwSctpAssocStatAssocId.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwSctpAssocStatEntry

hwSctpAssocStatEntry 1.3.6.1.4.1.2011.2.6.7.6.1.7.1
This table is used to query statistic of a SCTP association. The index of this entry is hwSctpAssocStatAssocId.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwSctpAssocStatEntry  

hwSctpAssocStatAssocId 1.3.6.1.4.1.2011.2.6.7.6.1.7.1.1
SCTP association ID Constructed by Protocol-Type, MGC-index/Proxy-index, IUA-Link-ID/H248-Interface-ID/SIP-Interface-ID; Format:xyzzzzzz(Hex) a) x for Protocol-Type: IUA(0),H.248(1),SIP(2); b) y for MGC-index/Proxy-index: if x is IUA(0), y fixed to 0; if x is H.248(1), y for MGC index; if x is SIP(2), y for Proxy index; c) z for IUA-Link-ID/H248-Interface-ID/SIP-Interface-ID: if x is IUA(0), zzzzzz for IUA LinkNo; if x is H.248(1), zzzzzz for H248 interface ID; if x is SIP(2), zzzzzz for SIP interface ID;
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwSctpAssocStatT1Expired 1.3.6.1.4.1.2011.2.6.7.6.1.7.1.2
The expired times of the T1 timer
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpAssocStatT2Expired 1.3.6.1.4.1.2011.2.6.7.6.1.7.1.3
The expired times of the T2 timer
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpAssocStatRetransChunks 1.3.6.1.4.1.2011.2.6.7.6.1.7.1.4
The number of retransmitted data chunks
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpAssocStatSendDataChunks 1.3.6.1.4.1.2011.2.6.7.6.1.7.1.5
The number of transmitted data chunks.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpAssocStatRevDataChunks 1.3.6.1.4.1.2011.2.6.7.6.1.7.1.6
The number of received data chunks
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpAssocStatRecPackets 1.3.6.1.4.1.2011.2.6.7.6.1.7.1.7
The number of received SCTP packets
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpAssocStatRecErrPackets 1.3.6.1.4.1.2011.2.6.7.6.1.7.1.8
The number of received error SCTP packets
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpAssocStatOperStatus 1.3.6.1.4.1.2011.2.6.7.6.1.7.1.9
Clearing the statistics of the associations. Options: 1. clear(1) -clear
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER clear(1)  

hwSctpAssocStatSentSctpPackets 1.3.6.1.4.1.2011.2.6.7.6.1.7.1.10
The number of the transmitted SCTP packets
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatAssocCurEstab 1.3.6.1.4.1.2011.2.6.7.6.1.8.1
The number of current associations
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatAssocActEstab 1.3.6.1.4.1.2011.2.6.7.6.1.8.2
The number of associations initiated by the local end
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatAssocPassiveEstab 1.3.6.1.4.1.2011.2.6.7.6.1.8.3
The number of associations initiated by the remote end
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatAssocActFail 1.3.6.1.4.1.2011.2.6.7.6.1.8.4
The number of failure associations initiated by the local end
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatAssocPassiveFail 1.3.6.1.4.1.2011.2.6.7.6.1.8.5
The number of failure associations initiated by the remote end
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatAssocAborted 1.3.6.1.4.1.2011.2.6.7.6.1.8.6
The number of abort associations
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatAssocShutdown 1.3.6.1.4.1.2011.2.6.7.6.1.8.7
The number of shutdown associations
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatRecOotb 1.3.6.1.4.1.2011.2.6.7.6.1.8.8
The number of received abnormal data chunks at the local end
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatSendCtrlChunks 1.3.6.1.4.1.2011.2.6.7.6.1.8.9
The number of transmitted control data chunks
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatSendOrderChunks 1.3.6.1.4.1.2011.2.6.7.6.1.8.10
The number of transmitted ordered data chunks
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatSendUnorderChunks 1.3.6.1.4.1.2011.2.6.7.6.1.8.11
The number of transmitted unordered data chunks
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatRecCtrlChunks 1.3.6.1.4.1.2011.2.6.7.6.1.8.12
The number of received control data chunks
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatRecOrderChunks 1.3.6.1.4.1.2011.2.6.7.6.1.8.13
The number of received ordered data chunks
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatRecUnorderChunks 1.3.6.1.4.1.2011.2.6.7.6.1.8.14
The number of received unordered data chunks
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatRetransDataChunks 1.3.6.1.4.1.2011.2.6.7.6.1.8.15
The number of retransmitted data chunks
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatFragmentedUsrMsgs 1.3.6.1.4.1.2011.2.6.7.6.1.8.16
The number of fragmented user messages
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatReassembledUsrMsgs 1.3.6.1.4.1.2011.2.6.7.6.1.8.17
The number of reassembled user messages
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatChecksumErrors 1.3.6.1.4.1.2011.2.6.7.6.1.8.18
The number of received checksum error packets
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatSentSctpPacks 1.3.6.1.4.1.2011.2.6.7.6.1.8.19
The number of the transmitted SCTP packets
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatRecvSctpPacks 1.3.6.1.4.1.2011.2.6.7.6.1.8.20
The number of the received SCTP packets
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpGlobalStatAdminStatus 1.3.6.1.4.1.2011.2.6.7.6.1.8.21
Clearing the system statistics. Options: 1. clear(1) -clear
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER clear(1)  

hwSctpParaRtoMin 1.3.6.1.4.1.2011.2.6.7.6.1.9.1
The minimum RTO. To the UA5000R15C05, this leaf can be read and written, the value range is (10..5000). To other products, this leaf just can be read, the default value is 1000. Unit: millisecond
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 10..5000  

hwSctpParaRtoMax 1.3.6.1.4.1.2011.2.6.7.6.1.9.2
The maximum RTO. For Mg interface, default value 3000. For Iua-Link, default value 60000. To the UA5000R15C05, the value range is (200..120000). To other products, the value range is (3000..90000). Unit: millisecond
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 200..120000  

hwSctpParaRtoInit 1.3.6.1.4.1.2011.2.6.7.6.1.9.3
The initial RTO. To the UA5000R15C05, the value range is (10..120000), the default value is 100. To other products, the value range is (1000..6000), the default value is 3000. Unit: millisecond
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 10..120000  

hwSctpParaValidCookieLife 1.3.6.1.4.1.2011.2.6.7.6.1.9.4
Cookie lifecycle. To the UA5000R15C05, the value range is (5000..120000). To other products, the value range is (30000..120000). Default: 60000 Unit: millisecond
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 5000..120000  

hwSctpParaMaxInitRetrans 1.3.6.1.4.1.2011.2.6.7.6.1.9.5
The maximum retransmit attempts of INIT To the UA5000R15C05, the value range is (1..10). To other products, the value range is (3..10). Default: 6
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..10  

hwSctpParaRtoAlpha 1.3.6.1.4.1.2011.2.6.7.6.1.9.6
Parameter of RTO Alpha To the UA5000R15C05, the default value is 13, the value range is (1..100). To other products, the default value is 12, the value range is (0..100).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..100  

hwSctpParaRtoBeta 1.3.6.1.4.1.2011.2.6.7.6.1.9.7
Parameter of RTO Beta To the UA5000R15C05, the value range is (1..100). To other products, the value range is (0..100). Default: 25
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..100  

hwSctpParaAssocMaxRetrans 1.3.6.1.4.1.2011.2.6.7.6.1.9.8
The maximum retransmit attempts in a association To the UA5000R15C05, the value range is (1..10), the default value is 8. To other products, the value range is (8..16), the default value is 10.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..16  

hwSctpParaPathMaxRetrans 1.3.6.1.4.1.2011.2.6.7.6.1.9.9
The maximum Retransmit attempts in a path To the UA5000R15C05, the value range is (1..10), the default value is 8. To other products, the value range is (3..8), the default value is 5.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..10  

hwSctpParaNoCongestionLevel 1.3.6.1.4.1.2011.2.6.7.6.1.9.10
Parameter of no-congestion level To the UA5000R15C05, the value range is (1..60). To other products, the value range is (0..60). Default: 40
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..60  

hwSctpParaLowCongestionLevel 1.3.6.1.4.1.2011.2.6.7.6.1.9.11
Parameter of low-congestion level. Default: 60
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 50..80  

hwSctpParaHighCongestionLevel 1.3.6.1.4.1.2011.2.6.7.6.1.9.12
Parameter of high-congestion level. Default: 80
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 70..100  

hwSctpParaHbInterval 1.3.6.1.4.1.2011.2.6.7.6.1.9.13
Heartbeat interval. To the UA5000R15C05, the value range is (1000..300000), the default value is 3000. To other products, the value range is (2000..120000), the default value is 30000. Unit: millisecond
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1000..300000  

hwSctpParaSendChecksum 1.3.6.1.4.1.2011.2.6.7.6.1.9.14
Sending the checksum. Options: 1. no(1) -indicates that the checksum is not Sending 2. yes(2) -indicates that the checksum is Sending Default: 2
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

hwSctpParaRecvChecksum 1.3.6.1.4.1.2011.2.6.7.6.1.9.15
Receiving the checksum. Options: 1. no(1) -indicates that the checksum is not Receiving 2. yes(2) -indicates that the checksum is Receiving Default: 2
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

hwSctpParaChecksumArith 1.3.6.1.4.1.2011.2.6.7.6.1.9.16
Checksum algorithm. Options: 1. adler32(1) -indicates that Checksum algorithm is ADLER32 2. crc32(2) -indicates that Checksum algorithm is CRC32 Default: 2
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER adler32(1), crc32(2)  

hwSctpParaSACKPolicy 1.3.6.1.4.1.2011.2.6.7.6.1.9.17
SACK policy: 0-NoTimer; 1-Timer; 2-Commix. Default: 2
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2  

hwSctpParaSACKPeriod 1.3.6.1.4.1.2011.2.6.7.6.1.9.18
SACK period. Default: 20 Unit: millisecond
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 20..500  

hwSctpParaSACKFrquency 1.3.6.1.4.1.2011.2.6.7.6.1.9.19
Parameter of SACK frequency Default: 1
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..5  

hwSctpParaMTU 1.3.6.1.4.1.2011.2.6.7.6.1.9.20
Parameter of MTU size. Default: 1500
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 68..64000  

hwIuaVersionString 1.3.6.1.4.1.2011.2.6.7.6.1.10.1
The version of the L2UA protocol
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

hwSctpVersionString 1.3.6.1.4.1.2011.2.6.7.6.1.11.1
SCTP version
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

hwSctpAssocInfoTable 1.3.6.1.4.1.2011.2.6.7.6.1.12
This table is used to query infomation of a SCTP association. The index of this table is hwSctpAssocId.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwSctpAssocInfoEntry

hwSctpAssocInfoEntry 1.3.6.1.4.1.2011.2.6.7.6.1.12.1
This table is used to query infomation of a SCTP association. The index of this entry is hwSctpAssocId.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwSctpAssocInfoEntry  

hwSctpAssocId 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.1
SCTP association ID Constructed by Protocol-Type, MGC-index/Proxy-index, IUA-Link-ID/H248-Interface-ID/SIP-Interface-ID; Format:xyzzzzzz(Hex) a) x for Protocol-Type: IUA(0),H.248(1),SIP(2); b) y for MGC-index/Proxy-index: if x is IUA(0), y fixed to 0; if x is H.248(1), y for MGC index; if x is SIP(2), y for Proxy index; c) z for IUA-Link-ID/H248-Interface-ID/SIP-Interface-ID: if x is IUA(0), zzzzzz for IUA LinkNo; if x is H.248(1), zzzzzz for H248 interface ID; if x is SIP(2), zzzzzz for SIP interface ID;
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..16  

hwSctpAssocState 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.2
Current status of the association Options: 1. closed(1) -indicates that the Current status of the association is closed 2. cookiewait(2) -indicates that the Current status of the association is down 3. cookieecho(3) -indicates that the Current status of the association is cookieecho 4. established(4) -indicates that the Current status of the association is established 5. shutdownpending(5) -indicates that the Current status of the association is shutdownpending 6. shutdownsent(6) -indicates that the Current status of the association is shutdownsent 7. shutdownreceived(7) -indicates that the Current status of the association is shutdownreceived 8. shutdownacksent(8) -indicates that the Current status of the association is shutdownacksent
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER closed(1), cookiewait(2), cookieecho(3), established(4), shutdownpending(5), shutdownsent(6), shutdownreceived(7), shutdownacksent(8)  

hwSctpAssocType 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.3
Association type. Options: 1. client(1) -indicates that the Association type is Client 2. server(2) -indicates that the Association type is Server
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER client(1), server(2)  

hwSctpAssocApplId 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.4
The upper-layer user ID
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..15  

hwSctpAssocLocalPort 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.5
Local port number
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..65534  

hwSctpAssocRemotePort 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.6
Remote port number
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..65534  

hwSctpAssocLocalIPaddr 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.7
The current local primary IP address
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

hwSctpAssocRemoteIPaddr 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.8
The current remote primary IP address
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

hwSctpAssocAllowHB 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.9
Whether transmitting HB message. Options: 1. no(1) -indicates not transmitting HB message 2. yes(2) -indicates transmitting HB message Default: 2
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

hwSctpAssocLocalRwnd 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.10
The size of the local receiver window
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

hwSctpAssocRemoteRwnd 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.11
The size of the remote receiver window
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

hwSctpAssocUnfirmDataChunks 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.12
The size of the unacknowledged data that is transmitted
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..8  

hwSctpAssocRemoteIP1addr 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.13
Remote IP address 1. Default: 80
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

hwSctpAssocRemoteIP1State 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.14
The current status of remote IP address 1. Options: 1. active(1) -active 2. inactive(2) -inactive
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2)  

hwSctpAssocRemoteIP1WaitAck 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.15
The number of the data blocks that is waiting for the acknowledgement by the remote SACK. Default: 2
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..8  

hwSctpAssocRemoteIP1Cwnd 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.16
The size of the congestion window. Default: 2
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwSctpAssocRemoteIP1Unfirm 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.17
The size of the unacknowledged data that is transmitted on the path. Default: 2
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..8  

hwSctpAssocRemoteIP1Rto 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.18
Retransmission Time-out (ms)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

hwSctpAssocRemoteIP1Srtt 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.19
Smoothed Round-trip Time (ms)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

hwSctpAssocRemoteIP1Rttvar 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.20
Round-trip Time Variation (ms)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

hwSctpAssocRemoteIP1AllowHB 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.21
Whether HB can be transmitted from this address. Options: 1. no(1) -indicates that the HB can't be transmitted from this address 2. yes(2) -indicates that the HB can be transmitted from this address
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

hwSctpAssocRemoteIP2addr 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.22
Remote IP address 2. Default: 80
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

hwSctpAssocRemoteIP2State 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.23
The current status of remote IP address 2 Options: 1. active(1) -indicates that the current status of remote IP address 2 is active 2. inactive(2) -indicates that the current status of remote IP address 2 is inactive
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2)  

hwSctpAssocRemoteIP2WaitAck 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.24
The number of the data that is waiting for the acknowledgement by the remote SACK. -1 returns by GET means associate with IP2 does not exist. Default: 2
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1 | 0..8  

hwSctpAssocRemoteIP2Cwnd 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.25
The size of the congestion window. -1 returns by GET means associate with IP2 does not exist. Default: 2
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1 | 0..8  

hwSctpAssocRemoteIP2Unfirm 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.26
The size of the unacknowledged data that is transmitted on the path. -1 returns by GET means associate with IP2 does not exist. Default: 2
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1 | 0..8  

hwSctpAssocRemoteIP2Rto 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.27
Retransmission Time-out(ms) -1 returns by GET means associate with IP2 does not exist.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1 | 0..65535  

hwSctpAssocRemoteIP2Srtt 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.28
Smoothed Round-trip Time (ms) -1 returns by GET means associate with IP2 does not exist.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1 | 0..65535  

hwSctpAssocRemoteIP2Rttvar 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.29
Round-trip Time Variation (ms) -1 returns by GET means associate with IP2 does not exist.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1 | 0..65535  

hwSctpAssocRemoteIP2AllowHB 1.3.6.1.4.1.2011.2.6.7.6.1.12.1.30
Whether HB can be sent from this address. Options: 1. no(1) -indicates that the HB can't be sent from this address 2. yes(2) -indicates that the HB can be sent from this address
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

hwIsdnIuaDuaErrStatsThresholdCfgTable 1.3.6.1.4.1.2011.2.6.7.6.1.13
Configuration table of L2UA IUA/DUA link error statistic threshold. The index of this table is hwIsdnIuaDuaErrLinkNoIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwIsdnIuaDuaErrStatsThresholdCfgEntry

hwIsdnIuaDuaErrStatsThresholdCfgEntry 1.3.6.1.4.1.2011.2.6.7.6.1.13.1
Configuration table of L2UA IUA/DUA link error statistic threshold. The index of this entry is hwIsdnIuaDuaErrLinkNoIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwIsdnIuaDuaErrStatsThresholdCfgEntry  

hwIsdnIuaDuaErrLinkNoIndex 1.3.6.1.4.1.2011.2.6.7.6.1.13.1.1
Link index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwIsdnIuaProtocolErrAlarmThreshold 1.3.6.1.4.1.2011.2.6.7.6.1.13.1.2
Threshold of IUA error alarm.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..25  

hwIsdnDuaProtocolErrAlarmThreshold 1.3.6.1.4.1.2011.2.6.7.6.1.13.1.3
Threshold of DUA error alarm.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..25  

hwMifSctpCfgParaTable 1.3.6.1.4.1.2011.2.6.7.6.1.14
This table is used to config SCTP protocol parameters of a SCTP association. The indexes of this table are hwMifSctpCfgParaProtoType and hwMifSctpCfgParaInterfaceId.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMifSctpCfgParaEntry

hwMifSctpCfgParaEntry 1.3.6.1.4.1.2011.2.6.7.6.1.14.1
This table is used to config SCTP protocol parameters of a SCTP association. The indexes of this entry are hwMifSctpCfgParaProtoType and hwMifSctpCfgParaInterfaceId.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMifSctpCfgParaEntry  

hwMifSctpCfgParaProtoType 1.3.6.1.4.1.2011.2.6.7.6.1.14.1.1
Protocol Type: IUA(0),H.248(1),SIP(2);
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..2  

hwMifSctpCfgParaInterfaceId 1.3.6.1.4.1.2011.2.6.7.6.1.14.1.2
IUA-Link-ID/H248-Interface-ID/SIP-Interface-ID: if Protocol Type is IUA(0), this parameter for IUA LinkNo; if Protocol Type is H.248(1), this parameter for H248 interface ID; if Protocol Type is SIP(2), this parameter for SIP interface ID;
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwMifSctpCfgParaMaxInStreamNum 1.3.6.1.4.1.2011.2.6.7.6.1.14.1.3
Maximum number of inbound streams.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 2..1024  

hwMifSctpCfgParaMaxOutStreamNum 1.3.6.1.4.1.2011.2.6.7.6.1.14.1.4
Maximum number of outbound streams
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 2..1024  

hwMifSctpCfgParaRtoMin 1.3.6.1.4.1.2011.2.6.7.6.1.14.1.5
The minimum RTO. Default: 1000 Unit: millisecond
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMifSctpCfgParaRtoMax 1.3.6.1.4.1.2011.2.6.7.6.1.14.1.6
The maximum RTO. Default: 3000(Mg interface),60000(Iua-Link) Unit: millisecond
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 3000..90000  

hwMifSctpCfgParaRtoInit 1.3.6.1.4.1.2011.2.6.7.6.1.14.1.7
The initial RTO. Unit: millisecond
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1000..90000  

hwMifSctpCfgParaValidCookieLife 1.3.6.1.4.1.2011.2.6.7.6.1.14.1.8
Cookie lifecycle. Unit: millisecond
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 30000..120000  

hwMifSctpCfgParaMaxInitRetrans 1.3.6.1.4.1.2011.2.6.7.6.1.14.1.9
The maximum retransmit attempts of INIT
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 3..10  

hwMifSctpCfgParaRtoAlpha 1.3.6.1.4.1.2011.2.6.7.6.1.14.1.10
Parameter of RTO Alpha
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..100  

hwMifSctpCfgParaRtoBeta 1.3.6.1.4.1.2011.2.6.7.6.1.14.1.11
Parameter of RTO Beta
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..100  

hwMifSctpCfgParaAssocMaxRetrans 1.3.6.1.4.1.2011.2.6.7.6.1.14.1.12
The maximum retransmit attempts in a association
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 8..16  

hwMifSctpCfgParaPathMaxRetrans 1.3.6.1.4.1.2011.2.6.7.6.1.14.1.13
The maximum Retransmit attempts in a path
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 3..8  

hwMifSctpCfgParaNoCongestionLevel 1.3.6.1.4.1.2011.2.6.7.6.1.14.1.14
Parameter of no-congestion level
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..60  

hwMifSctpCfgParaLowCongestionLevel 1.3.6.1.4.1.2011.2.6.7.6.1.14.1.15
Parameter of low-congestion level
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 50..80  

hwMifSctpCfgParaHighCongestionLevel 1.3.6.1.4.1.2011.2.6.7.6.1.14.1.16
Parameter of high-congestion level
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 70..100  

hwMifSctpCfgParaHbInterval 1.3.6.1.4.1.2011.2.6.7.6.1.14.1.17
Heartbeat interval. For Mg interface, 10000~120000 is valid. For Iua-Link, 2000~120000 is valid. Default: 10000(Mg interface),30000(Iua-Link) Unit: millisecond
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 2000..120000  

hwMifSctpCfgParaSendChecksum 1.3.6.1.4.1.2011.2.6.7.6.1.14.1.18
Sending the checksum. Options: 1. no(1) -indicates that the checksum is not Sending 2. yes(2) -indicates that the checksum is Sending
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

hwMifSctpCfgParaRecvChecksum 1.3.6.1.4.1.2011.2.6.7.6.1.14.1.19
Receiving the checksum. Options: 1. no(1) -indicates that the checksum is not Receiving 2. yes(2) -indicates that the checksum is Receiving
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

hwMifSctpCfgParaChecksumArith 1.3.6.1.4.1.2011.2.6.7.6.1.14.1.20
Checksum algorithm. Options: 1. adler32(1) -indicates that Checksum algorithm is ADLER32 2. crc32(2) -indicates that Checksum algorithm is CRC32
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER adler32(1), crc32(2)  

hwMifSctpRunningParaTable 1.3.6.1.4.1.2011.2.6.7.6.1.15
This table is used to query current running SCTP protocol parameter. The indexes of this table are hwMifSctpRunningParaProtoType and hwMifSctpRunningParaInterfaceId.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMifSctpRunningParaEntry

hwMifSctpRunningParaEntry 1.3.6.1.4.1.2011.2.6.7.6.1.15.1
This table is used to query current running SCTP protocol parameter. The indexes of this entry are hwMifSctpRunningParaProtoType and hwMifSctpRunningParaInterfaceId.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMifSctpRunningParaEntry  

hwMifSctpRunningParaProtoType 1.3.6.1.4.1.2011.2.6.7.6.1.15.1.1
Protocol Type: IUA(0),H.248(1),SIP(2);
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..2  

hwMifSctpRunningParaInterfaceId 1.3.6.1.4.1.2011.2.6.7.6.1.15.1.2
IUA-Link-ID/H248-Interface-ID/SIP-Interface-ID: if Protocol Type is IUA(0), this parameter for IUA LinkNo; if Protocol Type is H.248(1), this parameter for H248 interface ID; if Protocol Type is SIP(2), this parameter for SIP interface ID;
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwMifSctpRunningParaMaxInStreamNum 1.3.6.1.4.1.2011.2.6.7.6.1.15.1.3
Maximum number of inbound streams. Default: 33
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 2..33  

hwMifSctpRunningParaMaxOutStreamNum 1.3.6.1.4.1.2011.2.6.7.6.1.15.1.4
Maximum number of outbound streams. Default: 33
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 2..33  

hwMifSctpRunningParaRtoMin 1.3.6.1.4.1.2011.2.6.7.6.1.15.1.5
The minimum RTO. Default: 1000 Unit: millisecond
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMifSctpRunningParaRtoMax 1.3.6.1.4.1.2011.2.6.7.6.1.15.1.6
The maximum RTO. For Mg interface, default value 3000. For Iua-Link, default value 60000. Unit: millisecond
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 3000..90000  

hwMifSctpRunningParaRtoInit 1.3.6.1.4.1.2011.2.6.7.6.1.15.1.7
The initial RTO. Default: 1000 Unit: millisecond
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1000..6000  

hwMifSctpRunningParaValidCookieLife 1.3.6.1.4.1.2011.2.6.7.6.1.15.1.8
Cookie lifecycle. Default: 60000 Unit: millisecond
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 30000..120000  

hwMifSctpRunningParaMaxInitRetrans 1.3.6.1.4.1.2011.2.6.7.6.1.15.1.9
The maximum retransmit attempts of INIT. Default: 8
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 3..10  

hwMifSctpRunningParaRtoAlpha 1.3.6.1.4.1.2011.2.6.7.6.1.15.1.10
Parameter of RTO Alpha. Default: 12
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..100  

hwMifSctpRunningParaRtoBeta 1.3.6.1.4.1.2011.2.6.7.6.1.15.1.11
Parameter of RTO Beta. Default: 25
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..100  

hwMifSctpRunningParaAssocMaxRetrans 1.3.6.1.4.1.2011.2.6.7.6.1.15.1.12
The maximum retransmit attempts in a association. Default: 10
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 8..16  

hwMifSctpRunningParaPathMaxRetrans 1.3.6.1.4.1.2011.2.6.7.6.1.15.1.13
The maximum Retransmit attempts in a path. Default: 5
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 3..8  

hwMifSctpRunningParaNoCongestionLevel 1.3.6.1.4.1.2011.2.6.7.6.1.15.1.14
Parameter of no-congestion level Default: 40
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..60  

hwMifSctpRunningParaLowCongestionLevel 1.3.6.1.4.1.2011.2.6.7.6.1.15.1.15
Parameter of low-congestion level Default: 60
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 50..80  

hwMifSctpRunningParaHighCongestionLevel 1.3.6.1.4.1.2011.2.6.7.6.1.15.1.16
Parameter of high-congestion level. Default: 80
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 70..100  

hwMifSctpRunningParaHbInterval 1.3.6.1.4.1.2011.2.6.7.6.1.15.1.17
Heartbeat interval. For Mg interface, default value 10000. Default: 30000 Unit: millisecond
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 2000..120000  

hwMifSctpRunningParaSendChecksum 1.3.6.1.4.1.2011.2.6.7.6.1.15.1.18
Sending the checksum. Options: 1. no(1) -indicates that the checksum is not Sending 2. yes(2) -indicates that the checksum is Sending Default: 2
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

hwMifSctpRunningParaRecvChecksum 1.3.6.1.4.1.2011.2.6.7.6.1.15.1.19
Receiving the checksum. Options: 1. no(1) -indicates that the checksum is not Receiving 2. yes(2) -indicates that the checksum is Receiving Default: 2
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

hwMifSctpRunningParaChecksumArith 1.3.6.1.4.1.2011.2.6.7.6.1.15.1.20
Checksum algorithm. Options: 1. adler32(1) -indicates that Checksum algorithm is ADLER32 2. crc32(2) -indicates that Checksum algorithm is CRC32 Default: 2
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER adler32(1), crc32(2)  

hwSctpGlobalParaTable 1.3.6.1.4.1.2011.2.6.7.6.1.16
OBJECT IDENTIFIER    

hwSctpGlobalParaSendChecksum 1.3.6.1.4.1.2011.2.6.7.6.1.16.1
Sending the checksum: Options: 1. no(1) -indicates that the checksum is not Sending 2. yes(2) -indicates that the checksum is Sending Default: 2
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

hwSctpGlobalParaRecvChecksum 1.3.6.1.4.1.2011.2.6.7.6.1.16.2
Receiving the checksum. Options: 1. no(1) -indicates that the checksum is not Receiving 2. yes(2) -indicates that the checksum is Receiving Default: 2
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

hwIASSigtranL2uaLinkUnestTrap 1.3.6.1.4.1.2011.2.6.7.6.3.2.1.0.1
This notification indicates that the L2UA link is not established.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwIASSigtranL2uaLinkActiveTrap 1.3.6.1.4.1.2011.2.6.7.6.3.2.1.0.2
This notification indicates that the L2UA link is actived.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwIASSigtranL2uaLinksetDownTrap 1.3.6.1.4.1.2011.2.6.7.6.3.2.1.0.3
This notification indicates that the L2UA linkset is not activated.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwIASSigtranL2uaLinksetActiveTrap 1.3.6.1.4.1.2011.2.6.7.6.3.2.1.0.4
This notification indicates that the L2UA linkset is activated.
Status: current Access: read-write
NOTIFICATION-TYPE