HUAWEI-VOICEUSER-MIB

File: HUAWEI-VOICEUSER-MIB.mib (180681 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
HUAWEI-MIB HUAWEI-DEVICE-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
private Integer32 Unsigned32
MODULE-COMPLIANCE OBJECT-GROUP NOTIFICATION-GROUP
TEXTUAL-CONVENTION IpAddress TimeTicks
Counter32 RowStatus DisplayString
huaweiUtility hwConfigChangeIP

Defined Types

HwPstnCTPConfigEntry  
SEQUENCE    
  hwPstnCTPConfigIndex Integer32
  hwPstnCTPMgId Integer32
  hwPstnCTPTerminationID OCTET STRING
  hwPstnCTPTelNo OCTET STRING
  hwPstnCTPRowStatus RowStatus
  hwPstnCTPLayerFlag INTEGER
  hwPstnCTPPriorityFlag INTEGER
  hwPstnCTPPotsLineType INTEGER
  hwPstnCTPDCTime Integer32
  hwPstnCTPFSKDelayInterval Integer32
  hwPstnCTPCidTransWhen INTEGER
  hwPstnCTPCidFormat INTEGER
  hwPstnCTPVQEAgc INTEGER
  hwPstnCTPVQESns INTEGER
  hwPstnCTPVQEAgcLevel Integer32
  hwPstnCTPVQESnsLevel Integer32
  hwPstnCTPDspInputGain Integer32
  hwPstnCTPDspOutputGain Integer32
  hwPstnCTPDetectANSbarBySingleToneFlag INTEGER
  hwPstnCTPBellANSFlag INTEGER
  hwPstnCTPDspParaTemplate OCTET STRING
  hwPstnCTPCidFskMode INTEGER
  hwPstnCTPCidTasPattern INTEGER
  hwPstnCTPUserGroupid Integer32
  hwPstnCTPDigitMapGroupName OCTET STRING
  hwPstnCTPForceSendFsk INTEGER
  hwPstnCTPFSKAlertInterval Integer32
  hwPstnCTPConfigDefaultCli OCTET STRING
  hwPstnCTPEOCTime Integer32
  hwPstnCTPRemoteBlockPowerDeny INTEGER

HwPstnCTPOperEntry  
SEQUENCE    
  hwPstnCTPOperIndex Integer32
  hwPstnCTPSrvState INTEGER
  hwPstnCTPAdminState INTEGER
  hwPstnCTPAdminOper INTEGER
  hwPstnCTPSrvStateChange TimeTicks
  hwPstnCTPAdminStateChange TimeTicks
  hwPstnCTPMaxCobTime Integer32
  hwPstnCTPOnexpire INTEGER
  hwPstnCTPRegState INTEGER
  hwPstnCTPCallState INTEGER
  hwPstnCTPCallWaitState INTEGER

HwMgPortStatisticsInfoEntry  
SEQUENCE    
  hwMgPortStatInfoIndex Integer32
  hwPstnCTPStatTotalNum Integer32
  hwPstnCTPStatFaultNum Integer32
  hwPstnCTPStatIdleNum Integer32
  hwPstnCTPStatOffhookNum Integer32
  hwPstnCTPStatParkingNum Integer32
  hwPstnCTPStatRingNum Integer32
  hwMgPortStatInfoTotalNum Integer32
  hwMgPortStatInfoUseableNum Integer32
  hwMgPortStatInfoBusyNum Integer32
  hwMgPortStatInfoFaultNum Integer32
  hwMgPortStatInfoForbiddenNum Integer32

HwBraCTPConfigEntry  
SEQUENCE    
  hwBraCTPConfigIndex Integer32
  hwBraCTPMgId Integer32
  hwBraCTPTerminationID OCTET STRING
  hwBraCTPTelNo OCTET STRING
  hwBraCTPLinkSetNo Integer32
  hwBraCTPIuaIID Integer32
  hwBraCTPRowStatus RowStatus
  hwBraCTPPriorityFlag INTEGER
  hwBraCTPLayerFlag INTEGER
  hwBraCTPUniErrReport INTEGER
  hwBraCTPAutoResumeLimit Integer32
  hwBraCTPIuaTextIID OCTET STRING
  hwBraCTPPowerDialerSupport INTEGER
  hwBraCTPUserGroupid Integer32
  hwBraCTPDigitMapGroupName OCTET STRING
  hwBraCTPConfigIncomingcallChangeName OCTET STRING
  hwBraCTPConfigOutgoingcallChangeName OCTET STRING
  hwBraCTPConfigDefaultCli OCTET STRING
  hwBraCTPConfigDefaultCliMode INTEGER
  hwBraCTPConfigBearCapability INTEGER
  hwBraCTPConfigCalledPartyNumType INTEGER
  hwBraCTPConfigCalledPartyNumInternationalPrefixFlag INTEGER
  hwBraCTPConfigCalledPartyNumNationalPrefixFlag INTEGER

HwBraCTPOperEntry  
SEQUENCE    
  hwBraCTPOperIndex Integer32
  hwBraCTPB1SrvState INTEGER
  hwBraCTPB2SrvState INTEGER
  hwBraCTPB1AdminState INTEGER
  hwBraCTPB2AdminState INTEGER
  hwBraCTPAdminOper INTEGER
  hwBraCTPDState INTEGER
  hwBraCTPB1SrvStateChange TimeTicks
  hwBraCTPB2SrvStateChange TimeTicks
  hwBraCTPB1AdminStateChange TimeTicks
  hwBraCTPB2AdminStateChange TimeTicks
  hwBraCTPDStateChange TimeTicks
  hwBraCTPMaxCobTime Integer32
  hwBraCTPOnexpire INTEGER
  hwBraCTPAutoResumeTimes Integer32

HwBraCTPStatisticsEntry  
SEQUENCE    
  hwBraCTPStatIndex Integer32
  hwBraCTPStatTotalNum Integer32
  hwBraCTPStatFaultNum Integer32
  hwBraCTPStatIdleNum Integer32
  hwBraCTPStatBusyNum Integer32

HwPraCTPConfigEntry  
SEQUENCE    
  hwPraCTPConfigIndex Integer32
  hwPraCTPMgId Integer32
  hwPraCTPTerminationID OCTET STRING
  hwPraCTPLinkSetNo Integer32
  hwPraCTPIuaIID Integer32
  hwPraCTPRowStatus RowStatus
  hwPraCTPLayerFlag INTEGER
  hwPraCTPPriorityFlag INTEGER
  hwPraCTPUniErrReport INTEGER
  hwPraCTPSubChnMask BITS
  hwPraCTPTelNo OCTET STRING
  hwPraCTPAutoResumeLimit Integer32
  hwPraCTPIuaTextIID OCTET STRING
  hwPraCTPPowerDialerSupport INTEGER
  hwPraCTPUserGroupid Integer32
  hwPraCTPDigitMapGroupName OCTET STRING
  hwPraCTPConfigIncomingcallChangeName OCTET STRING
  hwPraCTPConfigOutgoingcallChangeName OCTET STRING
  hwPraCTPConfigDefaultCli OCTET STRING
  hwPraCTPConfigDefaultCliMode INTEGER
  hwPraCTPConfigBearCapability INTEGER
  hwPraCTPConfigCalledPartyNumType INTEGER
  hwPraCTPConfigCalledPartyNumInternationalPrefixFlag INTEGER
  hwPraCTPConfigCalledPartyNumNationalPrefixFlag INTEGER

HwPraCTPOperEntry  
SEQUENCE    
  hwPraCTPOperIndex Integer32
  hwPraCTPBchnSrvState OCTET STRING
  hwPraCTPBchnAdminState OCTET STRING
  hwPraCTPAdminOper INTEGER
  hwPraCTPDState INTEGER
  hwPraCTPMaxCobTime Integer32
  hwPraCTPOnexpire INTEGER
  hwPraCTPAutoResumeTimes Integer32

HwPortStateTraceOperEntry  
SEQUENCE    
  hwPortStateTraceOperFrameId Integer32
  hwPortStateTraceOperType INTEGER
  hwPortStateTraceOperReportType Integer32

HwPmbsCTPConfigEntry  
SEQUENCE    
  hwPmbsCTPConfigIndex Integer32
  hwPmbsCTPLinkSetNo Integer32
  hwPmbsCTPluaIID Integer32
  hwPmbsCTPRowStatus RowStatus
  hwPmbsCTPIuaTextIID OCTET STRING

HwPmbsCTPOperEntry  
SEQUENCE    
  hwPmbsCTPOperIndex Integer32
  hwPmbsCTPPLinkState BITS

HwPstnCTPRightConfigEntry  
SEQUENCE    
  hwPstnCTPRightConfigIndex Integer32
  hwPstnCTPRightPortBindIndex Integer32
  hwPstnCTPRightCallHold INTEGER
  hwPstnCTPRightThreeParty INTEGER
  hwPstnCTPRightConf INTEGER
  hwPstnCTPRightCt INTEGER
  hwPstnCTPRightCw INTEGER
  hwPstnCTPRightMcid INTEGER
  hwPstnCTPRightMwi INTEGER
  hwPstnCTPRightTp INTEGER
  hwPstnCTPRightCd INTEGER
  hwPstnCTPRightUus1 INTEGER
  hwPstnCTPRightUus2 INTEGER
  hwPstnCTPRightUus3 INTEGER
  hwPstnCTPRightCentrexNo Unsigned32
  hwPstnCTPRightCentrexPrefix OCTET STRING
  hwPstnCTPRightCentrexFlag INTEGER
  hwPstnCTPRightMwiMode INTEGER
  hwPstnCTPRightHotTime Integer32
  hwPstnCTPRightHotLineNum OCTET STRING
  hwPstnCTPRightDialTone INTEGER
  hwPstnCTPRightCfbNum OCTET STRING
  hwPstnCTPRightCfuNum OCTET STRING
  hwPstnCTPRightCfnrNum OCTET STRING
  hwPstnCTPRightCfnrTime Integer32
  hwPstnCTPRightAnonymousCall INTEGER
  hwPstnCTPRightAuthName OCTET STRING
  hwPstnCTPRightAuthPassword OCTET STRING
  hwPstnCTPRightEndConfigIndex Integer32
  hwPstnCTPRightAuthPasswordMode INTEGER
  hwPstnCTPRightAuthHA1 OCTET STRING
  hwPstnCTPRightAutoReversePolarity INTEGER
  hwPstnCTPRightDisplayNameMode INTEGER
  hwPstnCTPRightDisplayName OCTET STRING
  hwPstnCTPRightHotLine INTEGER
  hwPstnCTPRightPermanentHold INTEGER
  hwPstnCTPRightCutoffDisconnect INTEGER
  hwPstnCTPRightSccClass INTEGER
  hwPstnCTPRightPermanentHoldMode INTEGER
  hwPstnCTPRightPermanentHoldTime Integer32
  hwPstnCTPRightFastDisconnect INTEGER
  hwPstnCTPRightDc INTEGER

HwCTPExternNumberConfigEntry  
SEQUENCE    
  hwCTPExternNumberConfigIndex Integer32
  hwCTPExternNumberPortBindIndex Integer32
  hwCTPExternNumber OCTET STRING
  hwCTPExternRowStatus RowStatus
  hwCTPExternUserGroupid Integer32

HwBraCTPRightConfigEntry  
SEQUENCE    
  hwBraCTPRightConfigIndex Integer32
  hwBraCTPRightPortBindIndex Integer32
  hwBraCTPRightAuthName OCTET STRING
  hwBraCTPRightAuthPassword OCTET STRING
  hwBraCTPRightEndConfigIndex Integer32
  hwBraCTPRightAuthPasswordMode INTEGER
  hwBraCTPRightAuthHA1 OCTET STRING
  hwBraCTPRightCentrexNo Unsigned32
  hwBraCTPRightCentrexPrefix OCTET STRING
  hwBraCTPRightCentrexFlag INTEGER
  hwBraCTPRightMwiMode INTEGER
  hwBraCTPRightCallHold INTEGER
  hwBraCTPRightThreeParty INTEGER
  hwBraCTPRightConf INTEGER
  hwBraCTPRightCt INTEGER
  hwBraCTPRightCw INTEGER
  hwBraCTPRightMcid INTEGER
  hwBraCTPRightMwi INTEGER

HwPraCTPRightConfigEntry  
SEQUENCE    
  hwPraCTPRightConfigIndex Integer32
  hwPraCTPRightPortBindIndex Integer32
  hwPraCTPRightAuthName OCTET STRING
  hwPraCTPRightAuthPassword OCTET STRING
  hwPraCTPRightEndConfigIndex Integer32
  hwPraCTPRightAuthPasswordMode INTEGER
  hwPraCTPRightAuthHA1 OCTET STRING
  hwPraCTPRightCentrexNo Unsigned32
  hwPraCTPRightCentrexPrefix OCTET STRING
  hwPraCTPRightCentrexFlag INTEGER
  hwPraCTPRightMwiMode INTEGER

HwR2CTPConfigEntry  
SEQUENCE    
  hwR2CTPConfigIndex Integer32
  hwR2CTPMgId Integer32
  hwR2CTPTerminationID OCTET STRING
  hwR2CTPSignalProfileIndex Integer32
  hwR2CTPSignalProfileName OCTET STRING
  hwR2CTPRowStatus RowStatus
  hwR2CTPPriorityFlag INTEGER
  hwR2CTPTelNo OCTET STRING
  hwR2CTPUserGroupid Integer32
  hwR2CTPDigitMapGroupName OCTET STRING
  hwR2CTPRemoteRingFlag INTEGER
  hwR2CTPConfigIncomingcallChangeName OCTET STRING
  hwR2CTPConfigOutgoingcallChangeName OCTET STRING

HwR2CTPOperEntry  
SEQUENCE    
  hwR2CTPOperIndex Integer32
  hwR2CTPBchnSrvState OCTET STRING
  hwR2CTPBchnAdminState OCTET STRING
  hwR2CTPAdminOper INTEGER
  hwR2CTPMaxCobTime Integer32
  hwR2CTPOnexpire INTEGER

HwR2CTPRightConfigEntry  
SEQUENCE    
  hwR2CTPRightConfigIndex Integer32
  hwR2CTPRightPortBindIndex Integer32
  hwR2CTPRightAuthName OCTET STRING
  hwR2CTPRightAuthPassword OCTET STRING
  hwR2CTPRightAuthPasswordMode INTEGER
  hwR2CTPRightAuthHA1 OCTET STRING

Defined Values

hwIASVoiceUser 1.3.6.1.4.1.2011.6.112
This MIB module defines MIB objects which provides voice user management.
MODULE-IDENTITY    

hwIASVoiceUserObjects 1.3.6.1.4.1.2011.6.112.1
OBJECT IDENTIFIER    

hwIASVoiceUserTrapsVbOids 1.3.6.1.4.1.2011.6.112.2
OBJECT IDENTIFIER    

hwIASVoiceUserTraps 1.3.6.1.4.1.2011.6.112.3
OBJECT IDENTIFIER    

hwIASVoiceUserCommonTraps 1.3.6.1.4.1.2011.6.112.3.1
OBJECT IDENTIFIER    

hwIASVoiceUserAlarmTraps 1.3.6.1.4.1.2011.6.112.3.2
OBJECT IDENTIFIER    

hwIASVoiceUserPortTraps 1.3.6.1.4.1.2011.6.112.3.1.1
OBJECT IDENTIFIER    

hwIASVoiceUserPortAlarmTraps 1.3.6.1.4.1.2011.6.112.3.2.1
OBJECT IDENTIFIER    

hwIASVoiceUserTsnAlarmTraps 1.3.6.1.4.1.2011.6.112.3.2.2
OBJECT IDENTIFIER    

hwPstnCTPConfigTable 1.3.6.1.4.1.2011.6.112.1.1
This table is used to add, delete, modify, and query the PSTN user. The index of this table is hwPstnCTPConfigIndex. The service attributes of a PSTN port include the gateway ID, terminal ID, telephone number, whether to support layering configuration, priority flag of the port for the overload control, user type, power-off interval, FSK delay interval, time for issuing the calling number, format for issuing the calling number, and limited pulse dialing. Through the table, you can configure, modify, and query the above-mentioned attributes of the PSTN user.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwPstnCTPConfigEntry

hwPstnCTPConfigEntry 1.3.6.1.4.1.2011.6.112.1.1.1
This table is used to add, delete, modify, and query the PSTN user. The index of this entry is hwPstnCTPConfigIndex. The service attributes of a PSTN port include the gateway ID, terminal ID, telephone number, whether to support layering configuration, priority flag of the port for the overload control, user type, power-off interval, FSK delay interval, time for issuing the calling number, format for issuing the calling number, and limited pulse dialing. Through the table, you can configure, modify, and query the above-mentioned attributes of the PSTN user.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwPstnCTPConfigEntry  

hwPstnCTPConfigIndex 1.3.6.1.4.1.2011.6.112.1.1.1.1
Indicates the frame/slot/port. 24 0 0011000 | xxxxxxxx | xxxxxx | xxxxxxx | 0000 port frame slot port 0 type The highest 7 bits indicate the type of port, for PSTN port, must be 0x18 the next 8 bits indicate the frame ID, the next 6 bits indicate the slot ID, the next 7 bits indicate the port ID, the last 4 bits must be 0. The type of port include: E1 port = 0x16 PSTN port = 0x18 BRA port = 0x19 AT0 port = 0x1b
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwPstnCTPMgId 1.3.6.1.4.1.2011.6.112.1.1.1.2
Indicates the MG ID.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..16777215  

hwPstnCTPTerminationID 1.3.6.1.4.1.2011.6.112.1.1.1.3
Indicates the terminal ID (only the character string of digit type is supported).
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwPstnCTPTelNo 1.3.6.1.4.1.2011.6.112.1.1.1.4
Indicates the telephone number.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwPstnCTPRowStatus 1.3.6.1.4.1.2011.6.112.1.1.1.5
Indicates the row status.The operations include activate, shut down, not start, create and register, create and wait, and delete. The operations are not used in the V8R61.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

hwPstnCTPLayerFlag 1.3.6.1.4.1.2011.6.112.1.1.1.6
Indicates whether to layer. Options: 1. noLayer(1) -not to layer 2. layer(2) -to layer 3. null(-1) -invalid value
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noLayer(1), layer(2), null(-1)  

hwPstnCTPPriorityFlag 1.3.6.1.4.1.2011.6.112.1.1.1.7
Indicates the priority of the terminal. Options: 1. cat1(1) -the highest priority 2. cat2(2) -the middle priority 3. cat3(3) -the lowest priority
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER cat1(1), cat2(2), cat3(3)  

hwPstnCTPPotsLineType 1.3.6.1.4.1.2011.6.112.1.1.1.8
Indicates the subscriber type. Options: 1. del(1) -DEL 2. lcPBX(2) -Loop Calling PBX 3. ecPBX(3) -earth calling PBX 4. payPhone(4) -PayPhone
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER del(1), lcPBX(2), ecPBX(3), payPhone(4)  

hwPstnCTPDCTime 1.3.6.1.4.1.2011.6.112.1.1.1.9
Indicates the disconnect clear interval. Unit: 10ms
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 10..100  

hwPstnCTPFSKDelayInterval 1.3.6.1.4.1.2011.6.112.1.1.1.10
Indicates the FSK delay interval. Unit: 10ms
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..100  

hwPstnCTPCidTransWhen 1.3.6.1.4.1.2011.6.112.1.1.1.11
Indicates the time for delivering the caller ID. Options: 1. afterRing(1) -transmit CID after ringing 2. beforeRing(2) -transmit CID before ringing
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER afterRing(1), beforeRing(2)  

hwPstnCTPCidFormat 1.3.6.1.4.1.2011.6.112.1.1.1.12
Indicates the format of the caller ID. Options: 1. sdmfFsk(1) -SDMF FSK format 2. mdmfFsk(2) -MDMF FSK format 3. dtmf(3) -DTMF format 4. russia(4) -russia format 5. etsi(5) -etsi format
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER sdmfFsk(1), mdmfFsk(2), dtmf(3), russia(4), etsi(5)  

hwPstnCTPVQEAgc 1.3.6.1.4.1.2011.6.112.1.1.1.13
Indicates enable AGC or not. Options: 1. enable(1) -enable AGC 2. disable(2) -disable AGC
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hwPstnCTPVQESns 1.3.6.1.4.1.2011.6.112.1.1.1.14
Indicates enable SNS or not. Options: 1. enable(1) -enable SNS 2. disable(2) -disable SNS
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hwPstnCTPVQEAgcLevel 1.3.6.1.4.1.2011.6.112.1.1.1.15
Indicates set AGC target value. Unit: dbm0
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -24..-9  

hwPstnCTPVQESnsLevel 1.3.6.1.4.1.2011.6.112.1.1.1.16
Indicates set VQE noise suppression level. Unit: db
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 6..20  

hwPstnCTPDspInputGain 1.3.6.1.4.1.2011.6.112.1.1.1.17
Dsp input gain. 1: -10db 2: -9db 3: -8db 4: -7db 5: -6db 6: -5db 7: -4db 8: -3db 9: -2db 10: -1db 11: 0db 12: 1db 13: 2db 14: 3db 15: 4db 16: 5db Unit: db
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..16  

hwPstnCTPDspOutputGain 1.3.6.1.4.1.2011.6.112.1.1.1.18
Dsp output gain. 1: -10db 2: -9db 3: -8db 4: -7db 5: -6db 6: -5db 7: -4db 8: -3db 9: -2db 10: -1db 11: 0db 12: 1db 13: 2db 14: 3db 15: 4db 16: 5db 17: 6db 18: 7db 19: 8db 20: 9db 21: 10db Unit: db
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..21  

hwPstnCTPDetectANSbarBySingleToneFlag 1.3.6.1.4.1.2011.6.112.1.1.1.19
It indicates whether the ANSbar signal detected by SingleTone is supported. Options: 1. enable(1) -the ANSbar signal detected by SingleTone is supported 2. disable(2) -the ANSbar signal detected by SingleTone is not supported
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hwPstnCTPBellANSFlag 1.3.6.1.4.1.2011.6.112.1.1.1.20
It indicates whether the Bell ANS is supported. Options: 1. enable(1) -the Bell ANS is supported 2. disable(2) -the Bell ANS is not supported
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hwPstnCTPDspParaTemplate 1.3.6.1.4.1.2011.6.112.1.1.1.21
The index of dsp parameter template name.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..31)  

hwPstnCTPCidFskMode 1.3.6.1.4.1.2011.6.112.1.1.1.22
It indicates the mode of fsk. Options: 1. bell202(1) -bell 202 2. ccittv23(2) -ccitt v23 3. ntt(3) -ntt
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER bell202(1), ccittv23(2), ntt(3)  

hwPstnCTPCidTasPattern 1.3.6.1.4.1.2011.6.112.1.1.1.23
It indicates the mode of tas. Options: 1. noTas(1) -no tas 2. dtAs(2) -DT as
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER noTas(1), dtAs(2)  

hwPstnCTPUserGroupid 1.3.6.1.4.1.2011.6.112.1.1.1.24
It indicates the user group ID. -1 indicates clear the user group info.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..65535  

hwPstnCTPDigitMapGroupName 1.3.6.1.4.1.2011.6.112.1.1.1.25
It indicates the digitmap group name.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwPstnCTPForceSendFsk 1.3.6.1.4.1.2011.6.112.1.1.1.26
Indicates enable force send FSK or not. Options: 1. enable(1) -enable force send FSK 2. disable(2) -disable force send FSK
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hwPstnCTPFSKAlertInterval 1.3.6.1.4.1.2011.6.112.1.1.1.27
It indicates fskend to alert Interval. -1 indicate invalid value. Unit: 10ms
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..100 | -1  

hwPstnCTPConfigDefaultCli 1.3.6.1.4.1.2011.6.112.1.1.1.28
It indicates the default cli number of outgoing call.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwPstnCTPEOCTime 1.3.6.1.4.1.2011.6.112.1.1.1.29
Indicates the end of call interval. Unit: 10ms
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 10..100  

hwPstnCTPRemoteBlockPowerDeny 1.3.6.1.4.1.2011.6.112.1.1.1.30
Indicates the flag of remote block power deny. Options: 1. enable(1) - enable remote block power deny 2. disable(2) - disable remote block power deny
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hwPstnCTPOperTable 1.3.6.1.4.1.2011.6.112.1.2
It is used to maintain PSTN ports with the VSP feature. The index of this table is hwPstnCTPOperIndex. Through the table, you can query the states of PSTN ports, including the running status of the PSTN service, management status of the PSTN service, change time of the running status of the PSTN service, and change time of the management status of the PSTN service. Through the table, services on the PSTN port can be terminated, started, and the service status can be queried.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwPstnCTPOperEntry

hwPstnCTPOperEntry 1.3.6.1.4.1.2011.6.112.1.2.1
It is used to maintain PSTN ports with the VSP feature. The index of this entry is hwPstnCTPOperIndex. Through the table, you can query the states of PSTN ports, including the running status of the PSTN service, management status of the PSTN service, change time of the running status of the PSTN service, and change time of the management status of the PSTN service. Through the table, services on the PSTN port can be terminated, started, and the service status can be queried.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwPstnCTPOperEntry  

hwPstnCTPOperIndex 1.3.6.1.4.1.2011.6.112.1.2.1.1
Indicates the frame/slot/port. 24 0 0011000 | xxxxxxxx | xxxxxx | xxxxxxx | 0000 port frame slot port 0 type The highest 7 bits indicate the type of port, for PSTN port, must be 0x18 the next 8 bits indicate the frame ID, the next 6 bits indicate the slot ID, the next 7 bits indicate the port ID, the last 4 bits must be 0. The type of port include: E1 port = 0x16 PSTN port = 0x18 BRA port = 0x19 AT0 port = 0x1b
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwPstnCTPSrvState 1.3.6.1.4.1.2011.6.112.1.2.1.2
Indicates the running status of the service layer of the PSTN port. Options: 1. fault(1)-the port is fault 2. idle(2) -the user is idle 3. offHook(3) -the user off-hook 4. lock(4) -the user is locked 5. ring(5) -the user is ringing
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER fault(1), idle(2), offHook(3), lock(4), ring(5)  

hwPstnCTPAdminState 1.3.6.1.4.1.2011.6.112.1.2.1.3
Indicates the administration status of the service layer of the PSTN port. Options: 1. blockedLocally(1) -the service is blocked cause of the local reason 2. blockedRemotely(2) -the service is blocked cause of the remote reason 3. inService(3) -the service is normal 4. shuttingDown(4) -the service is shutting down 5. delayTest(5) -the user is waiting for testing
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER blockedLocally(1), blockedRemotely(2), inService(3), shuttingDown(4), delayTest(5)  

hwPstnCTPAdminOper 1.3.6.1.4.1.2011.6.112.1.2.1.4
Indicates the maintenance operation of the service layer of the PSTN port. Options: 1. endService(1) -stop service 2. startService(2) -start service 3. deferEndingService(3) -stop service gracefully
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER endService(1), startService(2), deferEndingService(3)  

hwPstnCTPSrvStateChange 1.3.6.1.4.1.2011.6.112.1.2.1.5
Indicates the service running status changing time of the PSTN port.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

hwPstnCTPAdminStateChange 1.3.6.1.4.1.2011.6.112.1.2.1.6
Indicates the service administration status changing time of the PSTN port.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

hwPstnCTPMaxCobTime 1.3.6.1.4.1.2011.6.112.1.2.1.7
Length of waiting timer for pstn user defer end service. 0 is not allowed to set. Default: 240 Unit: minute
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..1440  

hwPstnCTPOnexpire 1.3.6.1.4.1.2011.6.112.1.2.1.8
Indicates disposal mode when pstn user defer end service timeout. Options: 1. force(1) -force user to end service when end-service timeout 2. cancel(2) -cancel end service when end-service timeout Default: force(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER force(1), cancel(2)  

hwPstnCTPRegState 1.3.6.1.4.1.2011.6.112.1.2.1.9
Indicates the register status of the PSTN port. Options: 1.initializing(1) - the user has not send register request 2.registering(2) - the user has send register request and is waiting for response 3.failRegistered(3) - the user received failed response or register timeout 4.unregistering(4) - the user is unregistering 5.active(5) - the user is actived 6.deactive(6) - the user is deactived 7. invalidusertype(7) -- the user is not SIP user
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER initializing(1), registering(2), failRegistered(3), unregistering(4), active(5), deactive(6), invalidusertype(7)  

hwPstnCTPCallState 1.3.6.1.4.1.2011.6.112.1.2.1.10
Indicates the register status of the PSTN port. Options: 1. idle(1)- there is no call on the user 2. offhook(2)- the user hung up 3. dialing(3)- the user is dialing 4.establishing(4)- the call is establishing 5.ringing(5)- the phone is ringing 6.ringback(6)- the phone is ringback 7.connecting(7)- the call is connecting 8.connected(8)- the call is connected 9.hold(9)- the call is hold 10.disconnecting(10)- the call is disconnecting 11.locked(11)- the port is locked 12. invalidusertype(12) -- the user is not SIP user
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), offhook(2), dialing(3), establishing(4), ringing(5), ringback(6), connecting(7), connected(8), hold(9), disconnecting(10), locked(11), invalidusertype(12)  

hwPstnCTPCallWaitState 1.3.6.1.4.1.2011.6.112.1.2.1.11
Indicates the register status of the PSTN port. Options: 1. disable(1)- the service is disable 2. idle(2)- the is no callwaiting services 3. secondaryRinging(3)- the second part is ringing 4. secondaryConnecting(4)- the second part is connecting 5. secondaryConnected(5)- the second part is connected 6. secondaryDisconnecting(6)- the second part is disconnecting 7. invalidusertype(7) -- the user is not SIP user
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disable(1), idle(2), secondaryRinging(3), secondaryConnecting(4), secondaryConnected(5), secondaryDisconnecting(6), invalidusertype(7)  

hwMgPortStatisticsInfoTable 1.3.6.1.4.1.2011.6.112.1.3
This table is used to query the statistics of the MG service ports. The index of this table is hwMgPortStatInfoIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMgPortStatisticsInfoEntry

hwMgPortStatisticsInfoEntry 1.3.6.1.4.1.2011.6.112.1.3.1
This table is used to query the statistics of the MG service ports. The index of this entry is hwMgPortStatInfoIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMgPortStatisticsInfoEntry  

hwMgPortStatInfoIndex 1.3.6.1.4.1.2011.6.112.1.3.1.1
Indicates the frame ID. The GetNext (walk) operation is to collect the statistics of each specified shelf of the system. In the Get operation, if hwMgPortStatIndex is all F, the operation is to collect the statistics of the entire system; if hwMgPortStatIndex is not all F, the operation is to collect the statistics of the specified shelf.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwPstnCTPStatTotalNum 1.3.6.1.4.1.2011.6.112.1.3.1.2
Indicates the total number of the MGPSTN service ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwPstnCTPStatFaultNum 1.3.6.1.4.1.2011.6.112.1.3.1.3
Indicates the number of the MGPSTN faulty ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwPstnCTPStatIdleNum 1.3.6.1.4.1.2011.6.112.1.3.1.4
Indicates the number of the MGPSTN idle ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwPstnCTPStatOffhookNum 1.3.6.1.4.1.2011.6.112.1.3.1.5
Indicates the number of the MGPSTN off-hooked ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwPstnCTPStatParkingNum 1.3.6.1.4.1.2011.6.112.1.3.1.6
Indicates the number of the MGPSTN locked ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwPstnCTPStatRingNum 1.3.6.1.4.1.2011.6.112.1.3.1.7
Indicates the number of the MGPSTN ringing ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMgPortStatInfoTotalNum 1.3.6.1.4.1.2011.6.112.1.3.1.8
Indicates the total number of the MG service ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMgPortStatInfoUseableNum 1.3.6.1.4.1.2011.6.112.1.3.1.9
Indicates the number of the MG idle ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMgPortStatInfoBusyNum 1.3.6.1.4.1.2011.6.112.1.3.1.10
Indicates the number of the MG busy ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMgPortStatInfoFaultNum 1.3.6.1.4.1.2011.6.112.1.3.1.11
Indicates the number of the MG faulty ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMgPortStatInfoForbiddenNum 1.3.6.1.4.1.2011.6.112.1.3.1.12
Indicates the number of the MG blocked ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwBraCTPConfigTable 1.3.6.1.4.1.2011.6.112.1.4
It is used to configure the service attributes of a BRA port. It is used to add, delete, modify, and query the ISDN user with the VoIP feature. The index of this table is hwBraCTPConfigIndex. The attributes of an ISDN user with the VoIP feature include the gateway ID, terminal ID, IUA link group, interface ID, and telephone number. Through the table, you can configure, modify, and query the above-mentioned attributes of the BRA user.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwBraCTPConfigEntry

hwBraCTPConfigEntry 1.3.6.1.4.1.2011.6.112.1.4.1
It is used to configure the service attributes of a BRA port. It is used to add, delete, modify, and query the ISDN user with the VoIP feature. The index of this entry is hwBraCTPConfigIndex. The attributes of an ISDN user with the VoIP feature include the gateway ID, terminal ID, IUA link group, interface ID, and telephone number. Through the table, you can configure, modify, and query the above-mentioned attributes of the BRA user.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwBraCTPConfigEntry  

hwBraCTPConfigIndex 1.3.6.1.4.1.2011.6.112.1.4.1.1
Indicates the frame/slot/port. 25 0 0011001 | xxxxxxxx | xxxxxx | xxxxxxx | 0000 port frame slot port 0 type The highest 7 bits indicate the type of port, for BRA port, must be 0x19 the next 8 bits indicate the frame ID, the next 6 bits indicate the slot ID, the next 7 bits indicate the port ID, the last 4 bits must be 0. The type of port include: E1 port = 0x16 PSTN port = 0x18 BRA port = 0x19 AT0 port = 0x1b
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwBraCTPMgId 1.3.6.1.4.1.2011.6.112.1.4.1.2
Indicates the MG ID.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..16777215  

hwBraCTPTerminationID 1.3.6.1.4.1.2011.6.112.1.4.1.3
Indicates the start terminal ID (only the character string of digit type is supported).
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwBraCTPTelNo 1.3.6.1.4.1.2011.6.112.1.4.1.4
Indicates the BRA telephone number.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwBraCTPLinkSetNo 1.3.6.1.4.1.2011.6.112.1.4.1.5
Indicates the link set to which the BRA terminal belongs (the value range depends on the product specifications).
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hwBraCTPIuaIID 1.3.6.1.4.1.2011.6.112.1.4.1.6
Indicates the interface ID of the BRA terminal. -1 means this parameter is not used.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1 | 0..65535  

hwBraCTPRowStatus 1.3.6.1.4.1.2011.6.112.1.4.1.7
Indicates the row status.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

hwBraCTPPriorityFlag 1.3.6.1.4.1.2011.6.112.1.4.1.8
Indicates the priority of the terminal. Options: 1. cat1(1) -the highest priority 2. cat2(2) -the middle priority 3. cat3(3) -the lowest priority Default: cat3(3)
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER cat1(1), cat2(2), cat3(3)  

hwBraCTPLayerFlag 1.3.6.1.4.1.2011.6.112.1.4.1.9
Indicates whether to layer. Options: 1. noLayer(1) -not to layer 2. layer(2) -to layer 3. null(-1) -invalid value
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noLayer(1), layer(2), null(-1)  

hwBraCTPUniErrReport 1.3.6.1.4.1.2011.6.112.1.4.1.10
UNI fault report flag of bra user. Options: 1. disable(1) -disable 2. enable(2) -enable Default: disable(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwBraCTPAutoResumeLimit 1.3.6.1.4.1.2011.6.112.1.4.1.11
Indicates auto resume times threshold of bra user. Default: 20
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

hwBraCTPIuaTextIID 1.3.6.1.4.1.2011.6.112.1.4.1.12
Use the text to indicate the interface ID of the BRA terminal. Config area 0~65535. Display area 0~53.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..51)  

hwBraCTPPowerDialerSupport 1.3.6.1.4.1.2011.6.112.1.4.1.13
Powerdialer support flag of bra user. Options: 1. enable(1) -enable 2. disable(2) -disable Default: enable(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hwBraCTPUserGroupid 1.3.6.1.4.1.2011.6.112.1.4.1.14
It indicates the user group ID. -1 indicates clear the user group info.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..65535  

hwBraCTPDigitMapGroupName 1.3.6.1.4.1.2011.6.112.1.4.1.15
It indicates the digitmap group name.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwBraCTPConfigIncomingcallChangeName 1.3.6.1.4.1.2011.6.112.1.4.1.16
It indicates the number change of incomging call name.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwBraCTPConfigOutgoingcallChangeName 1.3.6.1.4.1.2011.6.112.1.4.1.17
It indicates the number change of outgoing call name.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwBraCTPConfigDefaultCli 1.3.6.1.4.1.2011.6.112.1.4.1.18
It indicates the default cli number of outgoing call.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwBraCTPConfigDefaultCliMode 1.3.6.1.4.1.2011.6.112.1.4.1.19
Indicates the mode of cli number. Options: 1. match(1) - match 2. overwrite(2) -overwrite 3. null(-1) -invalid value Default: match(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER match(1), overwrite(2), null(-1)  

hwBraCTPConfigBearCapability 1.3.6.1.4.1.2011.6.112.1.4.1.20
Indicates the bearCapability of bra user. Options: 1. speech(1) -speech 2. audio(2) -3.1k-audio 3. speechOraudio(3) -speech or 3.1k-audio 3. null(-1) -invalid value Default: speechOraudio(3)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER speech(1), audio(2), speechOraudio(3), null(-1)  

hwBraCTPConfigCalledPartyNumType 1.3.6.1.4.1.2011.6.112.1.4.1.21
Indicates the type of called party number. Options: 1. unknown(1) -unknown 2. national(2) -national 3. auto(3) -auto 4. international(4) -international 5. subscriber(5) -subscriber 6. null(-1) -invalid value Default: unknown(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), national(2), auto(3), international(4), subscriber(5), null(-1)  

hwBraCTPConfigCalledPartyNumInternationalPrefixFlag 1.3.6.1.4.1.2011.6.112.1.4.1.22
Indicates whether to add prefix on international number. Options: 1. enable(1) -enable 2. disable(2) -disable 3. null(-1) -invalid value Default: disable(2)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), null(-1)  

hwBraCTPConfigCalledPartyNumNationalPrefixFlag 1.3.6.1.4.1.2011.6.112.1.4.1.23
Indicates whether to add prefix on national number. Options: 1. enable(1) -enable 2. disable(2) -disable 3. null(-1) -invalid value Default: disable(2)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), null(-1)  

hwBraCTPOperTable 1.3.6.1.4.1.2011.6.112.1.5
It is used to perform operations on service attributes of a BRA port. Through this table, you can perform maintenance operations on an ISDN user with the VSP feature. The index of this table is hwBraCTPOperIndex. Different from the MG PSTN port, a BRA port contains two B channels and occupies two terminal IDs; however, only one terminal ID needs to be configured and this ID must be an even number. Then, the terminal ID in odd is allocated to the BRA port by default. Through this table, you can query the running status of the BRA B1/B2 service, management status of the BRA B1/B2 service, status of the BRA D channel, change time of the running status of the BRA B1/B2 service, and change time of the management status of the BRA B1/B2 service. Through the table, services on the BRA port can be terminated, started, and the service status can be queried.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwBraCTPOperEntry

hwBraCTPOperEntry 1.3.6.1.4.1.2011.6.112.1.5.1
It is used to perform operations on service attributes of a BRA port. Through this table, you can perform maintenance operations on an ISDN user with the VSP feature. The index of this entry is hwBraCTPOperIndex. Different from the MG PSTN port, a BRA port contains two B channels and occupies two terminal IDs; however, only one terminal ID needs to be configured and this ID must be an even number. Then, the terminal ID in odd is allocated to the BRA port by default. Through this table, you can query the running status of the BRA B1/B2 service, management status of the BRA B1/B2 service, status of the BRA D channel, change time of the running status of the BRA B1/B2 service, and change time of the management status of the BRA B1/B2 service. Through the table, services on the BRA port can be terminated, started, and the service status can be queried.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwBraCTPOperEntry  

hwBraCTPOperIndex 1.3.6.1.4.1.2011.6.112.1.5.1.1
Indicates the frame/slot/port. 25 0 0011001 | xxxxxxxx | xxxxxx | xxxxxxx | 0000 port frame slot port 0 type The highest 7 bits indicate the type of port, for BRA port, must be 0x19 the next 8 bits indicate the frame ID, the next 6 bits indicate the slot ID, the next 7 bits indicate the port ID, the last 4 bits must be 0. The type of port include: E1 port = 0x16 PSTN port = 0x18 BRA port = 0x19 AT0 port = 0x1b
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwBraCTPB1SrvState 1.3.6.1.4.1.2011.6.112.1.5.1.2
Indicates the running status of the service layer of the BRA B1 channel. Options: 1. idle(1) -the user is idle 2. busy(2) -the user is busy 3. fault(3) -the port is fault
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), busy(2), fault(3)  

hwBraCTPB2SrvState 1.3.6.1.4.1.2011.6.112.1.5.1.3
Indicates the running status of the service layer of the BRA B2 channel. Options: 1. idle(1) -the user is idle 2. busy(2) -the user is busy 3. fault(3) -the port is fault
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), busy(2), fault(3)  

hwBraCTPB1AdminState 1.3.6.1.4.1.2011.6.112.1.5.1.4
Indicates the administration status of the service layer of the BRA B1 channel. Options: 1. blockedLocally(1) -the service is blocked cause of local reason 2. blockedRemotely(2) -the service is blocked cause of remote reason 3. inService(3) -the service is normal 4. shuttingDown(4) -the service is shutting down
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER blockedLocally(1), blockedRemotely(2), inService(3), shuttingDown(4)  

hwBraCTPB2AdminState 1.3.6.1.4.1.2011.6.112.1.5.1.5
Indicates the administration status of the service layer of the BRA B2 channel. Options: 1. blockedLocally(1) -the service is blocked cause of local reason 2. blockedRemotely(2) -the service is blocked cause of remote reason 3. inService(3) -the service is normal 4. shuttingDown(4) -the service is shutting down
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER blockedLocally(1), blockedRemotely(2), inService(3), shuttingDown(4)  

hwBraCTPAdminOper 1.3.6.1.4.1.2011.6.112.1.5.1.6
Indicates the maintenance operation of the service layer of the BRA port. Options: 1. endService(1) -stop service 2. startService(2) -start service 3. deferEndingService(3) -stop service gracefully
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER endService(1), startService(2), deferEndingService(3)  

hwBraCTPDState 1.3.6.1.4.1.2011.6.112.1.5.1.7
Indicates the status of the BRA D channel. Options: 1. established(1) -established 2. block(2) -blocked 3. notConstruct(3) -unestablished 4. teiAlloced(4) -TEI is alloced 5. teiNotAlloced(5) -TEI is not alloced
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER established(1), block(2), notConstruct(3), teiAlloced(4), teiNotAlloced(5)  

hwBraCTPB1SrvStateChange 1.3.6.1.4.1.2011.6.112.1.5.1.8
Indicates the service running status changing time of the BRA B1 channel.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

hwBraCTPB2SrvStateChange 1.3.6.1.4.1.2011.6.112.1.5.1.9
Indicates the service running status changing time of the BRA B2 channel.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

hwBraCTPB1AdminStateChange 1.3.6.1.4.1.2011.6.112.1.5.1.10
Indicates the service administration status changing time of the BRA B1 channel.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

hwBraCTPB2AdminStateChange 1.3.6.1.4.1.2011.6.112.1.5.1.11
Indicates the service administration status changing time of the BRA B2 channel.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

hwBraCTPDStateChange 1.3.6.1.4.1.2011.6.112.1.5.1.12
Indicates the status changing time of the BRA D channel.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

hwBraCTPMaxCobTime 1.3.6.1.4.1.2011.6.112.1.5.1.13
Indicates the length of waiting timer for bra user defer end service. 0 is not allowed to set. Default:240 Unit: minute
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..1440  

hwBraCTPOnexpire 1.3.6.1.4.1.2011.6.112.1.5.1.14
Indicates the disposal mode when bra user defer end service timeout. Options: 1. force(1) -force user to end service 2. cancel(2) -cancel user's end service Default: force(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER force(1), cancel(2)  

hwBraCTPAutoResumeTimes 1.3.6.1.4.1.2011.6.112.1.5.1.15
Indicates the auto resume times of bra user.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

hwBraCTPStatisticsTable 1.3.6.1.4.1.2011.6.112.1.6
This table is used to query the statistics of the MG-BRA service ports. The index of this table is hwBraCTPStatIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwBraCTPStatisticsEntry

hwBraCTPStatisticsEntry 1.3.6.1.4.1.2011.6.112.1.6.1
This table is used to query the statistics of the MG-BRA service ports. The index of this entry is hwBraCTPStatIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwBraCTPStatisticsEntry  

hwBraCTPStatIndex 1.3.6.1.4.1.2011.6.112.1.6.1.1
Indicates the frame ID. The GetNext (walk) operation is to collect the statistics of each specified shelf of the system. In the Get operation, if hwMgPortStatIndex is all F, the operation is to collect the statistics of the entire system; if hwMgPortStatIndex is not all F, the operation is to collect the statistics of the specified shelf.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwBraCTPStatTotalNum 1.3.6.1.4.1.2011.6.112.1.6.1.2
Indicates the total number of the MGBRA service ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwBraCTPStatFaultNum 1.3.6.1.4.1.2011.6.112.1.6.1.3
Indicates the number of faulty ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwBraCTPStatIdleNum 1.3.6.1.4.1.2011.6.112.1.6.1.4
Indicates the number of idle ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwBraCTPStatBusyNum 1.3.6.1.4.1.2011.6.112.1.6.1.5
Indicates the number of busy ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwPraCTPConfigTable 1.3.6.1.4.1.2011.6.112.1.7
It is used to configure the service attributes of a PRA port. It is used to add, delete, modify, and query the PRA user with the VSP feature. The index of this table is the hwPraCTPConfigIndex. The attributes of a PRA user with the VoIP feature include the gateway ID, start terminal ID, IUA link group, and interface ID. Through the table, you can configure, modify, and query the above-mentioned attributes of the PRA user.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwPraCTPConfigEntry

hwPraCTPConfigEntry 1.3.6.1.4.1.2011.6.112.1.7.1
It is used to configure the service attributes of a PRA port. It is used to add, delete, modify, and query the PRA user with the VSP feature. The index of this entry is the hwPraCTPConfigIndex. The attributes of a PRA user with the VoIP feature include the gateway ID, start terminal ID, IUA link group, and interface ID. Through the table, you can configure, modify, and query the above-mentioned attributes of the PRA user.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwPraCTPConfigEntry  

hwPraCTPConfigIndex 1.3.6.1.4.1.2011.6.112.1.7.1.1
Indicates the frame/slot/port. 22 0 0010110 | xxxxxxxx | xxxxxx | xxxxxxx | 0000 port frame slot port 0 type The highest 7 bits indicate the type of port, for E1 port, must be 0x16 the next 8 bits indicate the frame ID, the next 6 bits indicate the slot ID, the next 7 bits indicate the port ID, the last 4 bits must be 0. The type of port include: E1 port = 0x16 PSTN port = 0x18 BRA port = 0x19 AT0 port = 0x1b
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwPraCTPMgId 1.3.6.1.4.1.2011.6.112.1.7.1.2
Indicates the MG ID.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..16777215  

hwPraCTPTerminationID 1.3.6.1.4.1.2011.6.112.1.7.1.3
Indicates the start terminal ID (only the character string of digit type is supported).
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwPraCTPLinkSetNo 1.3.6.1.4.1.2011.6.112.1.7.1.4
Indicates the link set to which the PRA terminal belongs (the value range depends on the product specifications).
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hwPraCTPIuaIID 1.3.6.1.4.1.2011.6.112.1.7.1.5
Indicates the interface ID of the PRA terminal. -1 means this parameter is not used.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1 | 0..65535  

hwPraCTPRowStatus 1.3.6.1.4.1.2011.6.112.1.7.1.6
Indicates the row status.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

hwPraCTPLayerFlag 1.3.6.1.4.1.2011.6.112.1.7.1.7
Indicates whether to layer. Options: 1. noLayer(1) -not to layer 2. layer(2) -to layer 3. null(-1) -invalid value
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noLayer(1), layer(2), null(-1)  

hwPraCTPPriorityFlag 1.3.6.1.4.1.2011.6.112.1.7.1.8
Indicates terminal priority. Options: 1. cat1(1) -the highest priority 2. cat2(2) -the middle priority 3. cat3(3) -the lowest priority Default: cat3(3)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER cat1(1), cat2(2), cat3(3)  

hwPraCTPUniErrReport 1.3.6.1.4.1.2011.6.112.1.7.1.9
Indicates UNI fault report flag of e1 port. Options: 1. disable(1) -disable UNI fault report of e1 port 2. enable(2) -enable UNI fault report of e1 port Default: disable(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPraCTPSubChnMask 1.3.6.1.4.1.2011.6.112.1.7.1.10
Indicates from left to right, each bit indicates enable one sub channel(0-31) or not, 0 means disable, 1 means enable, sub channel 0 and 16 must enable. Default: 11111111111111111111111111111111
Status: current Access: read-write
OBJECT-TYPE    
  BITS bchn0(0), bchn1(1), bchn2(2), bchn3(3), bchn4(4), bchn5(5), bchn6(6), bchn7(7), bchn8(8), bchn9(9), bchn10(10), bchn11(11), bchn12(12), bchn13(13), bchn14(14), bchn15(15), bchn16(16), bchn17(17), bchn18(18), bchn19(19), bchn20(20), bchn21(21), bchn22(22), bchn23(23), bchn24(24), bchn25(25), bchn26(26), bchn27(27), bchn28(28), bchn29(29), bchn30(30), bchn31(31)  

hwPraCTPTelNo 1.3.6.1.4.1.2011.6.112.1.7.1.11
Indicates telphone number.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwPraCTPAutoResumeLimit 1.3.6.1.4.1.2011.6.112.1.7.1.12
Indicates auto resume times threshold of pra user. Default: 20
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

hwPraCTPIuaTextIID 1.3.6.1.4.1.2011.6.112.1.7.1.13
Use the text to indicate the interface ID of the PRA terminal.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..51)  

hwPraCTPPowerDialerSupport 1.3.6.1.4.1.2011.6.112.1.7.1.14
Powerdialer support flag of pra user. Options: 1. enable(1) -support power dialer 2. disable(2) -not support power dialer Default: enable(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hwPraCTPUserGroupid 1.3.6.1.4.1.2011.6.112.1.7.1.15
It indicates the user group ID. -1 indicates clear the user group info.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..65535  

hwPraCTPDigitMapGroupName 1.3.6.1.4.1.2011.6.112.1.7.1.16
It indicates the digitmap group name.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwPraCTPConfigIncomingcallChangeName 1.3.6.1.4.1.2011.6.112.1.7.1.17
It indicates the number change name of incoming call.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwPraCTPConfigOutgoingcallChangeName 1.3.6.1.4.1.2011.6.112.1.7.1.18
It indicates the number change name of outgoing call.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwPraCTPConfigDefaultCli 1.3.6.1.4.1.2011.6.112.1.7.1.19
It indicates the default cli number of outgoing call.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwPraCTPConfigDefaultCliMode 1.3.6.1.4.1.2011.6.112.1.7.1.20
Indicates the mode of cli number. Options: 1. match(1) -match 2. overwrite(2) -overwrite 3. null(0) -invalid value Default: match(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER match(1), overwrite(2), null(0)  

hwPraCTPConfigBearCapability 1.3.6.1.4.1.2011.6.112.1.7.1.21
Indicates the bearCapability of pra user. Options: 1. speech(1) -speech 2. audio(2) -3.1k-audio 3. speechOraudio(3) -speech or 3.1k-audio 4. null(0) -invalid value Default: speechOraudio(3)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER speech(1), audio(2), speechOraudio(3), null(0)  

hwPraCTPConfigCalledPartyNumType 1.3.6.1.4.1.2011.6.112.1.7.1.22
Indicates the type of called party number. Options: 1. unknown(1) -unknown 2. national(2) -national 3. auto(3) -auto 4. international(4) -international 5. subscriber(5) -subscriber 6. null(0) -invalid value Default: unknown(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), national(2), auto(3), international(4), subscriber(5), null(0)  

hwPraCTPConfigCalledPartyNumInternationalPrefixFlag 1.3.6.1.4.1.2011.6.112.1.7.1.23
Indicates whether to add prefix on international number. Options: 1. enable(1) -enable 2. disable(2) -disable 3. null(0) -invalid value Default: disable(2)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), null(0)  

hwPraCTPConfigCalledPartyNumNationalPrefixFlag 1.3.6.1.4.1.2011.6.112.1.7.1.24
Indicates whether to add prefix on national number. Options: 1. enable(1) -enable 2. disable(2) -disable 3. null(0) -invalid value Default: disable(2)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), null(0)  

hwPraCTPOperTable 1.3.6.1.4.1.2011.6.112.1.8
It is used to perform operations on service attributes of a PRA port. Through this table, you can perform maintenance operations on a PRA user with the VSP feature. The index of this table is hwPraCTPOperIndex. Through this table, you can query the running status of 32 B channels of the PRA service, management status of 32 B channels of the PRA service, and status of the PRA D channel. Through the table, services on the PRA port can be terminated, started, and the service status can be queried.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwPraCTPOperEntry

hwPraCTPOperEntry 1.3.6.1.4.1.2011.6.112.1.8.1
It is used to perform operations on service attributes of a PRA port. Through this table, you can perform maintenance operations on a PRA user with the VSP feature. The index of this entry is hwPraCTPOperIndex. Through this table, you can query the running status of 32 B channels of the PRA service, management status of 32 B channels of the PRA service, and status of the PRA D channel. Through the table, services on the PRA port can be terminated, started, and the service status can be queried.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwPraCTPOperEntry  

hwPraCTPOperIndex 1.3.6.1.4.1.2011.6.112.1.8.1.1
Indicates the frame/slot/port. 22 0 0010110 | xxxxxxxx | xxxxxx | xxxxxxx | 0000 port frame slot port 0 type The highest 7 bits indicate the type of port, for E1 port, must be 0x16 the next 8 bits indicate the frame ID, the next 6 bits indicate the slot ID, the next 7 bits indicate the port ID, the last 4 bits must be 0. The type of port include: E1 port = 0x16 PSTN port = 0x18 BRA port = 0x19 AT0 port = 0x1b
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwPraCTPBchnSrvState 1.3.6.1.4.1.2011.6.112.1.8.1.2
Indicates the running status of the service layer of the 32 B channels of the PRA. Each character corresponds to a timeslot. The value of the character is as follows: 1-Idle; 2-Busy; 3-Faulty; 4-Unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwPraCTPBchnAdminState 1.3.6.1.4.1.2011.6.112.1.8.1.3
Indicates the administration status of the service layer of the 32 B channels of the PRA. Each character corresponds to a timeslot. The value of the character is as follows: 1-blocked-locally; 2-blocked-remotely; 3-in-service;4-shutting-down.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwPraCTPAdminOper 1.3.6.1.4.1.2011.6.112.1.8.1.4
Indicates the service operation. Options: 1. endService(1) -stop service 2. startService(2) -start service 3. deferEndingService(3) -stop service gracefully
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER endService(1), startService(2), deferEndingService(3)  

hwPraCTPDState 1.3.6.1.4.1.2011.6.112.1.8.1.5
Indicates the status of the PRA D channel. Options: 1. established(1) -established 2. block(2) -blocked 3. notConstruct(3) -unestablished
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER established(1), block(2), notConstruct(3)  

hwPraCTPMaxCobTime 1.3.6.1.4.1.2011.6.112.1.8.1.6
Indicates length of waiting timer for pra user defer end service. 0 is not allowed to set. Default: 240 Unit: minute
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..1440  

hwPraCTPOnexpire 1.3.6.1.4.1.2011.6.112.1.8.1.7
Indicates disposal mode when pra user defer end service timeout. Options: 1. force(1) -force end service 2. cancel(2) -cancel end service Default: force(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER force(1), cancel(2)  

hwPraCTPAutoResumeTimes 1.3.6.1.4.1.2011.6.112.1.8.1.8
Indicates auto resume times of pra user.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

hwPortStateTraceOperTable 1.3.6.1.4.1.2011.6.112.1.9
It is used to trace port status. The index of this table is hwPortStateTraceFrameId. This table traces states of the MG PSTN ports and MG BRA ports in real time, which contains trace start, trace end, and handshake operations.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwPortStateTraceOperEntry

hwPortStateTraceOperEntry 1.3.6.1.4.1.2011.6.112.1.9.1
It is used to trace port status. The index of this entry is hwPortStateTraceFrameId. This table traces states of the MG PSTN ports and MG BRA ports in real time, which contains trace start, trace end, and handshake operations.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwPortStateTraceOperEntry  

hwPortStateTraceOperFrameId 1.3.6.1.4.1.2011.6.112.1.9.1.1
Indicates the frame ID.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwPortStateTraceOperType 1.3.6.1.4.1.2011.6.112.1.9.1.2
Indicates the operation type. Options: 1. stop(1) -stop tracing 2. start(2) -start tracing 3. handshake(3) -handshake
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER stop(1), start(2), handshake(3)  

hwPortStateTraceOperReportType 1.3.6.1.4.1.2011.6.112.1.9.1.3
Indicates the report type (adopting the bit table): Bit0: indicates to report the running status change of the physical layer. Bit1: indicates to report the administration status change of the physical layer. Bit2: indicates to report the running status change of the service layer. Bit3: indicates to report the administration status change of the service layer.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..15  

hwUserDataTrapSequence 1.3.6.1.4.1.2011.6.112.1.10
OBJECT IDENTIFIER    

hwPstnUserDataTrapSequence 1.3.6.1.4.1.2011.6.112.1.10.1
Indicates that the Trap sequence is reported after the PSTN subscriber data changes.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwBraUserDataChangeSequence 1.3.6.1.4.1.2011.6.112.1.10.2
Indicates that the Trap sequence is reported after the BRA subscriber data changes.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwPraUserDataChangeSequence 1.3.6.1.4.1.2011.6.112.1.10.3
Indicates that the Trap sequence is reported after the PRA subscriber data changes.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwR2UserDataChangeSequence 1.3.6.1.4.1.2011.6.112.1.10.4
Indicates that the Trap sequence is reported after the R2 subscriber data changes.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwPmbsCTPConfigTable 1.3.6.1.4.1.2011.6.112.1.11
This table is used to config PMBS user. The index of this table is hwPmbsCTPConfigIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwPmbsCTPConfigEntry

hwPmbsCTPConfigEntry 1.3.6.1.4.1.2011.6.112.1.11.1
This table is used to config PMBS user. The index of this entry is hwPmbsCTPConfigIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwPmbsCTPConfigEntry  

hwPmbsCTPConfigIndex 1.3.6.1.4.1.2011.6.112.1.11.1.1
Indicates the frame/slot/port. The PMBS user must be configurated on BRA port. 25 0 0011001 | xxxxxxxx | xxxxxx | xxxxxxx | 0000 port frame slot port 0 type The highest 7 bits indicate the type of port, for BRA port, must be 0x19 the next 8 bits indicate the frame ID, the next 6 bits indicate the slot ID, the next 7 bits indicate the port ID, the last 4 bits must be 0. The type of port include: E1 port = 0x16 PSTN port = 0x18 BRA port = 0x19 AT0 port = 0x1b
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwPmbsCTPLinkSetNo 1.3.6.1.4.1.2011.6.112.1.11.1.2
IUA LinkSetNo.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hwPmbsCTPluaIID 1.3.6.1.4.1.2011.6.112.1.11.1.3
IUA Interface ID.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535 | -1  

hwPmbsCTPRowStatus 1.3.6.1.4.1.2011.6.112.1.11.1.4
Row status.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

hwPmbsCTPIuaTextIID 1.3.6.1.4.1.2011.6.112.1.11.1.5
Use the text to indicate the interface ID of the PMBS terminal.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..51)  

hwPmbsCTPOperTable 1.3.6.1.4.1.2011.6.112.1.12
This table is used to operate the PMBS user. The index of this table is hwPmbsCTPOperIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwPmbsCTPOperEntry

hwPmbsCTPOperEntry 1.3.6.1.4.1.2011.6.112.1.12.1
This table is used to operate the PMBS user. The index of this entry is hwPmbsCTPOperIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwPmbsCTPOperEntry  

hwPmbsCTPOperIndex 1.3.6.1.4.1.2011.6.112.1.12.1.1
Indicates the frame/slot/port. 25 0 0011001 | xxxxxxxx | xxxxxx | xxxxxxx | 0000 port frame slot port 0 type The highest 7 bits indicate the type of port, for BRA port, must be 0x19 the next 8 bits indicate the frame ID, the next 6 bits indicate the slot ID, the next 7 bits indicate the port ID, the last 4 bits must be 0. The type of port include: E1 port = 0x16 PSTN port = 0x18 BRA port = 0x19 AT0 port = 0x1b
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwPmbsCTPPLinkState 1.3.6.1.4.1.2011.6.112.1.12.1.2
Indicates from left to right, each bit indicates plink status of one TEI(0-62) or not, 0 means plink not established, 1 means plink established.
Status: current Access: read-only
OBJECT-TYPE    
  BITS tei1(0), tei2(1), tei3(2), tei4(3), tei5(4), tei6(5), tei7(6), tei8(7), tei9(8), tei10(9), tei11(10), tei12(11), tei13(12), tei14(13), tei15(14), tei16(15), tei17(16), tei18(17), tei19(18), tei20(19), tei21(20), tei22(21), tei23(22), tei24(23), tei25(24), tei26(25), tei27(26), tei28(27), tei29(28), tei30(29), tei31(30), tei32(31), tei33(32), tei34(33), tei35(34), tei36(35), tei37(36), tei38(37), tei39(38), tei40(39), tei41(40), tei42(41), tei43(42), tei44(43), tei45(44), tei46(45), tei47(46), tei48(47), tei49(48), tei50(49), tei51(50), tei52(51), tei53(52), tei54(53), tei55(54), tei56(55), tei57(56), tei58(57), tei59(58), tei60(59), tei61(60), tei62(61), tei63(62)  

hwPstnCTPRightConfigTable 1.3.6.1.4.1.2011.6.112.1.13
This table is used to config PSTN user's right and servicedata. The indexes of this table are hwPstnCTPRightConfigIndex, hwPstnCTPRightPortBindIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwPstnCTPRightConfigEntry

hwPstnCTPRightConfigEntry 1.3.6.1.4.1.2011.6.112.1.13.1
This table is used to config PSTN user's right and servicedata. The indexes of this entry are hwPstnCTPRightConfigIndex, hwPstnCTPRightPortBindIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwPstnCTPRightConfigEntry  

hwPstnCTPRightConfigIndex 1.3.6.1.4.1.2011.6.112.1.13.1.1
Indicates the frame/slot/port. 31 0 0011000 | xxxxxxxx | xxxxxx | xxxxxxx | 0000 port frame slot port 0 type The highest 7 bits indicate the type of port, for PSTN port, must be 0x18 the next 8 bits indicate the frame ID, the next 6 bits indicate the slot ID, the next 7 bits indicate the port ID, the last 4 bits must be 0. The type of port include: E1 port = 0x16 PSTN port = 0x18 BRA port = 0x19 AT0 port = 0x1b
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwPstnCTPRightPortBindIndex 1.3.6.1.4.1.2011.6.112.1.13.1.2
Indicates the telephone number index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

hwPstnCTPRightCallHold 1.3.6.1.4.1.2011.6.112.1.13.1.3
Indicates the right flag of callhold. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPstnCTPRightThreeParty 1.3.6.1.4.1.2011.6.112.1.13.1.4
Indicates the right flag of three-party. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPstnCTPRightConf 1.3.6.1.4.1.2011.6.112.1.13.1.5
Indicates the right flag of conf. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPstnCTPRightCt 1.3.6.1.4.1.2011.6.112.1.13.1.6
Indicates the right flag of ct. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPstnCTPRightCw 1.3.6.1.4.1.2011.6.112.1.13.1.7
Indicates the right flag of cw. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPstnCTPRightMcid 1.3.6.1.4.1.2011.6.112.1.13.1.8
Indicates the right flag of mcid. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPstnCTPRightMwi 1.3.6.1.4.1.2011.6.112.1.13.1.9
Indicates the right flag of mwi. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPstnCTPRightTp 1.3.6.1.4.1.2011.6.112.1.13.1.10
Indicates the right flag of tp. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPstnCTPRightCd 1.3.6.1.4.1.2011.6.112.1.13.1.11
Indicates the right flag of cd. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPstnCTPRightUus1 1.3.6.1.4.1.2011.6.112.1.13.1.12
Indicates the right flag of uus1. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPstnCTPRightUus2 1.3.6.1.4.1.2011.6.112.1.13.1.13
Indicates the right flag of uus2. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPstnCTPRightUus3 1.3.6.1.4.1.2011.6.112.1.13.1.14
Indicates the right flag of uus3. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPstnCTPRightCentrexNo 1.3.6.1.4.1.2011.6.112.1.13.1.15
It is used to set centrex NO. of SipPstnUser, 4294967295 means to clear the configuration.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..4294967295  

hwPstnCTPRightCentrexPrefix 1.3.6.1.4.1.2011.6.112.1.13.1.16
Indicates the CentrexPrefix of SipPstnUser.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..7)  

hwPstnCTPRightCentrexFlag 1.3.6.1.4.1.2011.6.112.1.13.1.17
Indicates the CentrexFlag of SipPstnUser. Options: 1. dialDirectly(1) -dial directly 2. dialSecondary(2) -dial secondary
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dialDirectly(1), dialSecondary(2)  

hwPstnCTPRightMwiMode 1.3.6.1.4.1.2011.6.112.1.13.1.18
Indicates the MwiMode of SipPstnUser. Options: 1. deferred(1) -deferred 2. immediate(2) -immediate 3. combine(3) -combine
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER deferred(1), immediate(2), combine(3)  

hwPstnCTPRightHotTime 1.3.6.1.4.1.2011.6.112.1.13.1.19
Indicates the HotTime of SipPstnUser. Unit: second
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

hwPstnCTPRightHotLineNum 1.3.6.1.4.1.2011.6.112.1.13.1.20
Indicates the HotLineNum of SipPstnUser, the length of hotlinenum mustn't exceed 64.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwPstnCTPRightDialTone 1.3.6.1.4.1.2011.6.112.1.13.1.21
Indicates the DialTone of SipPstnUser. Options: 1. normal(1) -normal tone 2. special(2) -special tone 3. mw(3) -message waiting tone 4. stutter(4) -stutter tone
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), special(2), mw(3), stutter(4)  

hwPstnCTPRightCfbNum 1.3.6.1.4.1.2011.6.112.1.13.1.22
Indicates the CfbNum of SipPstnUser.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwPstnCTPRightCfnrNum 1.3.6.1.4.1.2011.6.112.1.13.1.23
Indicates the CfnrNum of SipPstnUser.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwPstnCTPRightCfuNum 1.3.6.1.4.1.2011.6.112.1.13.1.24
Indicates the CfuNum of SipPstnUser.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwPstnCTPRightCfnrTime 1.3.6.1.4.1.2011.6.112.1.13.1.25
Indicates the CfnrTime of SipPstnUser. Unit: second
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

hwPstnCTPRightAnonymousCall 1.3.6.1.4.1.2011.6.112.1.13.1.26
Indicates the right flag of anonymous-call. Options: 1. disable(1) -disable anonymous-call 2. enable(2) -enable anonymous-call
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPstnCTPRightAuthName 1.3.6.1.4.1.2011.6.112.1.13.1.27
Indicates the authorization username of sippstnuser. The character set is unrestricted.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwPstnCTPRightAuthPassword 1.3.6.1.4.1.2011.6.112.1.13.1.28
Indicates the authorization password of sippstnuser. The character set is unrestricted.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwPstnCTPRightEndConfigIndex 1.3.6.1.4.1.2011.6.112.1.13.1.29
Indicates the end shelf/slot/port.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hwPstnCTPRightAuthPasswordMode 1.3.6.1.4.1.2011.6.112.1.13.1.30
Indicates the authorization mode of the password for sippstnuser. Options: 1. password(1) -authorized by password 2. ha1(2) --authorized by ha1
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER password(1), ha1(2)  

hwPstnCTPRightAuthHA1 1.3.6.1.4.1.2011.6.112.1.13.1.31
Indicates the authorization HA1 value of sippstnuser. The character set is unrestricted.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwPstnCTPRightAutoReversePolarity 1.3.6.1.4.1.2011.6.112.1.13.1.32
Indicates the right flag of auto reverse polarity. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPstnCTPRightDisplayNameMode 1.3.6.1.4.1.2011.6.112.1.13.1.33
Indicates the right flag of display name mode. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPstnCTPRightDisplayName 1.3.6.1.4.1.2011.6.112.1.13.1.34
Indicates the display name string.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

hwPstnCTPRightHotLine 1.3.6.1.4.1.2011.6.112.1.13.1.35
Indicates the right flag of hotline. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPstnCTPRightPermanentHold 1.3.6.1.4.1.2011.6.112.1.13.1.36
Indicates the right flag of permanent-hold. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPstnCTPRightCutoffDisconnect 1.3.6.1.4.1.2011.6.112.1.13.1.37
Indicates the right flag of cutoff-disconnect. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPstnCTPRightSccClass 1.3.6.1.4.1.2011.6.112.1.13.1.38
Indicates the right flag of SCC class service, for example call-park, call-pickup, EBO. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPstnCTPRightPermanentHoldMode 1.3.6.1.4.1.2011.6.112.1.13.1.39
Indicates the PermanentHoldMode of SipPstnUser. Options: 1. norecall(1) - no recall 2. reminder(2) -reminder 3. recall(3) -recall
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER norecall(1), reminder(2), recall(3)  

hwPstnCTPRightPermanentHoldTime 1.3.6.1.4.1.2011.6.112.1.13.1.40
Indicates the PermanentHoldTime of SipPstnUser. Unit: second
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 12..1023  

hwPstnCTPRightFastDisconnect 1.3.6.1.4.1.2011.6.112.1.13.1.41
Indicates the right flag of fast-disconnect. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPstnCTPRightDc 1.3.6.1.4.1.2011.6.112.1.13.1.42
Indicates the right flag of dual communication. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwCTPExternNumberConfigTable 1.3.6.1.4.1.2011.6.112.1.14
This table is used to config extern number of the PSTN or ISDN user. The indexes of this table are hwCTPExternNumberConfigIndex, hwCTPExternNumberPortBindIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwCTPExternNumberConfigEntry

hwCTPExternNumberConfigEntry 1.3.6.1.4.1.2011.6.112.1.14.1
This table is used to config extern number of the PSTN or ISDN user. The indexes of this entry are hwCTPExternNumberConfigIndex, hwCTPExternNumberPortBindIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwCTPExternNumberConfigEntry  

hwCTPExternNumberConfigIndex 1.3.6.1.4.1.2011.6.112.1.14.1.1
Indicates the frame/slot/port. 31 0 xxxxxxx | xxxxxxxx | xxxxxx | xxxxxxx | 0000 port frame slot port 0 type The highest 7 bits indicate the type of port the next 8 bits indicate the frame ID, the next 6 bits indicate the slot ID, the next 7 bits indicate the port ID, the last 4 bits must be 0. The type of port include: E1 port = 0x16 PSTN port = 0x18 BRA port = 0x19 AT0 port = 0x1b
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwCTPExternNumberPortBindIndex 1.3.6.1.4.1.2011.6.112.1.14.1.2
Indicates the extend number index. If the value equal -1, then return the idle index of this shelf/slot/port.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..65534  

hwCTPExternNumber 1.3.6.1.4.1.2011.6.112.1.14.1.3
Indicates the extend number. - means to delete this extern number.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..64)  

hwCTPExternRowStatus 1.3.6.1.4.1.2011.6.112.1.14.1.4
RowStatus
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

hwCTPExternUserGroupid 1.3.6.1.4.1.2011.6.112.1.14.1.5
It indicates the user group ID. -1 indicates clear the user group info.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..65535  

hwBraCTPRightConfigTable 1.3.6.1.4.1.2011.6.112.1.15
This table is used to config BRA user's right and servicedata. The indexes of this table are hwBraCTPRightConfigIndex, hwBraCTPRightPortBindIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwBraCTPRightConfigEntry

hwBraCTPRightConfigEntry 1.3.6.1.4.1.2011.6.112.1.15.1
This table is used to config BRA user's right and servicedata. The indexes of this entry are hwBraCTPRightConfigIndex, hwBraCTPRightPortBindIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwBraCTPRightConfigEntry  

hwBraCTPRightConfigIndex 1.3.6.1.4.1.2011.6.112.1.15.1.1
Indicates the frame/slot/port. 31 0 0011001 | xxxxxxxx | xxxxxx | xxxxxxx | 0000 port frame slot port 0 type The highest 7 bits indicate the type of port, for BRA port, must be 0x19 the next 8 bits indicate the frame ID, the next 6 bits indicate the slot ID, the next 7 bits indicate the port ID, the last 4 bits must be 0. The type of port include: E1 port = 0x16 PSTN port = 0x18 BRA port = 0x19 AT0 port = 0x1b
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwBraCTPRightPortBindIndex 1.3.6.1.4.1.2011.6.112.1.15.1.2
Indicates the telephone number index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

hwBraCTPRightAuthName 1.3.6.1.4.1.2011.6.112.1.15.1.3
Indicates the authorization username of sipbrauser. The character set is unrestricted.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwBraCTPRightAuthPassword 1.3.6.1.4.1.2011.6.112.1.15.1.4
Indicates the authorization password of sipbrauser. The character set is unrestricted.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwBraCTPRightEndConfigIndex 1.3.6.1.4.1.2011.6.112.1.15.1.5
Indicates the end shelf/slot/port.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hwBraCTPRightAuthPasswordMode 1.3.6.1.4.1.2011.6.112.1.15.1.6
Indicates the authorization mode of the password for sipbrauser. Options: 1. password(1) -authorized by password 2. ha1(2) -authorized by ha1
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER password(1), ha1(2)  

hwBraCTPRightAuthHA1 1.3.6.1.4.1.2011.6.112.1.15.1.7
Indicates the authorization HA1 value of sipbrauser. The character set is unrestricted.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwBraCTPRightCentrexNo 1.3.6.1.4.1.2011.6.112.1.15.1.8
It is used to set centrex NO. of SipBraUser, 4294967295 means to clear the configuration.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..4294967295  

hwBraCTPRightCentrexPrefix 1.3.6.1.4.1.2011.6.112.1.15.1.9
Indicates the CentrexPrefix of SipBraUser.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..7)  

hwBraCTPRightCentrexFlag 1.3.6.1.4.1.2011.6.112.1.15.1.10
Indicates the CentrexFlag of SipBraUser. Options: 1. dialDirectly(1) -dial directly 2. dialSecondary(2) -dial secondary
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dialDirectly(1), dialSecondary(2)  

hwBraCTPRightMwiMode 1.3.6.1.4.1.2011.6.112.1.15.1.11
Indicates the MwiMode of SipBraUser. Options: 1. deferred(1) -deferred 2. immediate(2) -immediate 3. combine(3) -combine
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER deferred(1), immediate(2), combine(3)  

hwBraCTPRightCallHold 1.3.6.1.4.1.2011.6.112.1.15.1.12
Indicates the right flag of callhold. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwBraCTPRightThreeParty 1.3.6.1.4.1.2011.6.112.1.15.1.13
Indicates the right flag of three-party. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwBraCTPRightConf 1.3.6.1.4.1.2011.6.112.1.15.1.14
Indicates the right flag of conf. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwBraCTPRightCt 1.3.6.1.4.1.2011.6.112.1.15.1.15
Indicates the right flag of ct. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwBraCTPRightCw 1.3.6.1.4.1.2011.6.112.1.15.1.16
Indicates the right flag of cw. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwBraCTPRightMcid 1.3.6.1.4.1.2011.6.112.1.15.1.17
Indicates the right flag of mcid. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwBraCTPRightMwi 1.3.6.1.4.1.2011.6.112.1.15.1.18
Indicates the right flag of mwi. Options: 1. disable(1) -disable 2. enable(2) -enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

hwPraCTPRightConfigTable 1.3.6.1.4.1.2011.6.112.1.16
This table is used to config PRA user's servicedata. The indexes of this table are hwPraCTPRightConfigIndex, hwPraCTPRightPortBindIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwPraCTPRightConfigEntry

hwPraCTPRightConfigEntry 1.3.6.1.4.1.2011.6.112.1.16.1
This table is used to config PRA user's servicedata. The indexes of this entry are hwPraCTPRightConfigIndex, hwPraCTPRightPortBindIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwPraCTPRightConfigEntry  

hwPraCTPRightConfigIndex 1.3.6.1.4.1.2011.6.112.1.16.1.1
Indicates the frame/slot/port. 31 0 0010110 | xxxxxxxx | xxxxxx | xxxxxxx | 0000 port frame slot port 0 type The highest 7 bits indicate the type of port, for E1 port, must be 0x16 the next 8 bits indicate the frame ID, the next 6 bits indicate the slot ID, the next 7 bits indicate the port ID, the last 4 bits must be 0. The type of port include: E1 port = 0x16 PSTN port = 0x18 BRA port = 0x19 AT0 port = 0x1b
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwPraCTPRightPortBindIndex 1.3.6.1.4.1.2011.6.112.1.16.1.2
Indicates the telephone number index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

hwPraCTPRightAuthName 1.3.6.1.4.1.2011.6.112.1.16.1.3
Indicates the authorization username of sipprauser. The character set is unrestricted.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwPraCTPRightAuthPassword 1.3.6.1.4.1.2011.6.112.1.16.1.4
Indicates the authorization password of sipprauser. The character set is unrestricted.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwPraCTPRightEndConfigIndex 1.3.6.1.4.1.2011.6.112.1.16.1.5
Indicates the end shelf/slot/port.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hwPraCTPRightAuthPasswordMode 1.3.6.1.4.1.2011.6.112.1.16.1.6
Indicates the authorization mode of the password for sipprauser. Options: 1. password(1) -authorized by password 2. ha1(2) -authorized by ha1
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER password(1), ha1(2)  

hwPraCTPRightAuthHA1 1.3.6.1.4.1.2011.6.112.1.16.1.7
Indicates the authorization HA1 value of sipprauser. The character set is unrestricted.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwPraCTPRightCentrexNo 1.3.6.1.4.1.2011.6.112.1.16.1.8
It is used to set centrex NO. of SipPraUser, 4294967295 means to clear the configuration.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..4294967295  

hwPraCTPRightCentrexPrefix 1.3.6.1.4.1.2011.6.112.1.16.1.9
Indicates the CentrexPrefix of SipPraUser.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..7)  

hwPraCTPRightCentrexFlag 1.3.6.1.4.1.2011.6.112.1.16.1.10
Indicates the CentrexFlag of SipPraUser. Options: 1. dialDirectly(1) -dial directly 2. dialSecondary(2) -dial secondary
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dialDirectly(1), dialSecondary(2)  

hwPraCTPRightMwiMode 1.3.6.1.4.1.2011.6.112.1.16.1.11
Indicates the MwiMode of SipPraUser. Options: 1. deferred(1) -deferred 2. immediate(2) -immediate 3. combine(3) -combine
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER deferred(1), immediate(2), combine(3)  

hwR2CTPConfigTable 1.3.6.1.4.1.2011.6.112.1.17
It is used to configure the service attributes of a R2 port. It is used to add, delete, modify, and query the R2 user with the VSP feature. The index of this table is the hwR2CTPConfigIndex. The attributes of a R2 user with the VoIP feature include the gateway ID, terminal ID, R2 profile index. Through the table, you can configure, modify, and query the above-mentioned attributes of the R2 user.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwR2CTPConfigEntry

hwR2CTPConfigEntry 1.3.6.1.4.1.2011.6.112.1.17.1
It is used to configure the service attributes of a R2 port. It is used to add, delete, modify, and query the R2 user with the VSP feature. The index of this entry is the hwR2CTPConfigIndex. The attributes of a R2 user with the VoIP feature include the gateway ID, terminal ID, R2 profile index. Through the table, you can configure, modify, and query the above-mentioned attributes of the R2 user.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwR2CTPConfigEntry  

hwR2CTPConfigIndex 1.3.6.1.4.1.2011.6.112.1.17.1.1
Indicates the frame/slot/port. 31 0 0010110 | xxxxxxxx | xxxxxx | xxxxxxx | 0000 port frame slot port 0 type The highest 7 bits indicate the type of port, for R2 port, must be 0x16 the next 8 bits indicate the frame ID, the next 6 bits indicate the slot ID, the next 7 bits indicate the port ID, the last 4 bits must be 0. The type of port include: E1 port = 0x16 PSTN port = 0x18 BRA port = 0x19 AT0 port = 0x1b
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwR2CTPMgId 1.3.6.1.4.1.2011.6.112.1.17.1.2
Indicates the MG ID.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..16777215  

hwR2CTPTerminationID 1.3.6.1.4.1.2011.6.112.1.17.1.3
Indicates the start terminal ID (only the character string of digit type is supported).
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwR2CTPSignalProfileIndex 1.3.6.1.4.1.2011.6.112.1.17.1.4
Indicates the R2 signal profile index.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..15  

hwR2CTPSignalProfileName 1.3.6.1.4.1.2011.6.112.1.17.1.5
Indicates the R2 signal profile name.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwR2CTPRowStatus 1.3.6.1.4.1.2011.6.112.1.17.1.6
Indicates the row status.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

hwR2CTPPriorityFlag 1.3.6.1.4.1.2011.6.112.1.17.1.7
Indicates terminal priority. Options: 1. cat1(1) -the highest priority 2. cat2(2) -the middle priority 3. cat3(3) -the lowest priority
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER cat1(1), cat2(2), cat3(3)  

hwR2CTPTelNo 1.3.6.1.4.1.2011.6.112.1.17.1.8
Indicates telphone number.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwR2CTPUserGroupid 1.3.6.1.4.1.2011.6.112.1.17.1.9
It indicates the user group ID. -1 indicates clear the user group info.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..65535  

hwR2CTPDigitMapGroupName 1.3.6.1.4.1.2011.6.112.1.17.1.10
It indicates the digitmap group name.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwR2CTPRemoteRingFlag 1.3.6.1.4.1.2011.6.112.1.17.1.11
Indicates RemoteRing. Options: 1. disable(1) -disable receive remote early media 2. enable(2) -enable receive remote early media 3. null(-1) -invalid value
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2), null(-1)  

hwR2CTPConfigIncomingcallChangeName 1.3.6.1.4.1.2011.6.112.1.17.1.12
It indicates the number change name of incoming call.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwR2CTPConfigOutgoingcallChangeName 1.3.6.1.4.1.2011.6.112.1.17.1.13
It indicates the number change name of outgoing call.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwR2CTPOperTable 1.3.6.1.4.1.2011.6.112.1.18
It is used to perform operations on service attributes of a R2 user port. Through this table, you can perform maintenance operations on a R2 user with the VSP feature. The index of this table is hwR2CTPOperIndex. Through this table, you can query the running status of 32 B channels of the R2 service, and management status of 32 B channels of the R2 service. Through the table, services on the R2 port can be terminated, started, and the service status can be queried.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwR2CTPOperEntry

hwR2CTPOperEntry 1.3.6.1.4.1.2011.6.112.1.18.1
It is used to perform operations on service attributes of a R2 user port. Through this table, you can perform maintenance operations on a R2 user with the VSP feature. The index of this entry is hwR2CTPOperIndex. Through this table, you can query the running status of 32 B channels of the R2 service, and management status of 32 B channels of the R2 service. Through the table, services on the R2 port can be terminated, started, and the service status can be queried.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwR2CTPOperEntry  

hwR2CTPOperIndex 1.3.6.1.4.1.2011.6.112.1.18.1.1
Indicates the frame/slot/port. 31 0 0010110 | xxxxxxxx | xxxxxx | xxxxxxx | 0000 port frame slot port 0 type The highest 7 bits indicate the type of port, for R2 port, must be 0x16 the next 8 bits indicate the frame ID, the next 6 bits indicate the slot ID, the next 7 bits indicate the port ID, the last 4 bits must be 0. The type of port include: E1 port = 0x16 PSTN port = 0x18 BRA port = 0x19 AT0 port = 0x1b
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwR2CTPBchnSrvState 1.3.6.1.4.1.2011.6.112.1.18.1.2
Indicates the running status of the service layer of the 32 B channels of the R2. Each character corresponds to a timeslot. The value of the character is as follows: 1-Idle; 2-Busy; 3-Faulty; 4-Unavailable.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwR2CTPBchnAdminState 1.3.6.1.4.1.2011.6.112.1.18.1.3
Indicates the administration status of the service layer of the 32 B channels of the R2. Each character corresponds to a timeslot. The value of the character is as follows: 1-blocked-locally; 2-blocked-remotely; 3-in-service;4-shutting-down;5-MGCblock;6-PBXblock;7-bothblock.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwR2CTPAdminOper 1.3.6.1.4.1.2011.6.112.1.18.1.4
Indicates the service operation. Options: 1. endService(1) -stop service 2. startService(2) -start service 3. deferEndingService(3) -stop service gracefully
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER endService(1), startService(2), deferEndingService(3)  

hwR2CTPMaxCobTime 1.3.6.1.4.1.2011.6.112.1.18.1.5
Indicates length of waiting timer for R2 user defer end service. 0 is not allowed to set. Default: 240 Unit: minute
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..1440  

hwR2CTPOnexpire 1.3.6.1.4.1.2011.6.112.1.18.1.6
Indicates disposal mode when R2 user defer end service timeout. Options: 1. force(1) -force end service 2. cancel(2) -cancel end service Default: force(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER force(1), cancel(2)  

hwR2CTPRightConfigTable 1.3.6.1.4.1.2011.6.112.1.19
This table is used to config R2 user's right. The indexes of this table are hwR2CTPRightConfigIndex, hwR2CTPRightPortBindIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwR2CTPRightConfigEntry

hwR2CTPRightConfigEntry 1.3.6.1.4.1.2011.6.112.1.19.1
This table is used to config R2 user's right. The indexes of this entry are hwR2CTPRightConfigIndex, hwR2CTPRightPortBindIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwR2CTPRightConfigEntry  

hwR2CTPRightConfigIndex 1.3.6.1.4.1.2011.6.112.1.19.1.1
Indicates the frame/slot/port. 31 0 0011000 | xxxxxxxx | xxxxxx | xxxxxxx | 0000 port frame slot port 0 type The highest 7 bits indicate the type of port, for PSTN port, must be 0x18 the next 8 bits indicate the frame ID, the next 6 bits indicate the slot ID, the next 7 bits indicate the port ID, the last 4 bits must be 0. The type of port include: E1 port = 0x16 PSTN port = 0x18 BRA port = 0x19 AT0 port = 0x1b
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwR2CTPRightPortBindIndex 1.3.6.1.4.1.2011.6.112.1.19.1.2
Indicates the telephone number index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

hwR2CTPRightAuthName 1.3.6.1.4.1.2011.6.112.1.19.1.3
Indicates the authorization username of sipR2user. The character set is unrestricted.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwR2CTPRightAuthPassword 1.3.6.1.4.1.2011.6.112.1.19.1.4
Indicates the authorization password of sipR2user. The character set is unrestricted.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

hwR2CTPRightAuthPasswordMode 1.3.6.1.4.1.2011.6.112.1.19.1.5
Indicates the authorization mode of the password for sipR2user. Options: 1. password(1) -authorized by password 2. ha1(2) -authorized by ha1
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER password(1), ha1(2)  

hwR2CTPRightAuthHA1 1.3.6.1.4.1.2011.6.112.1.19.1.6
Indicates the authorization HA1 value of sipR2user. The character set is unrestricted.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

hwLightTrapPortNum 1.3.6.1.4.1.2011.6.112.2.1
The number of the ports send light state trap.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 0..128  

hwLightTrapPortInfo 1.3.6.1.4.1.2011.6.112.2.2
The position and state of the ports.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  OCTET STRING Size(0..896)  

hwVoiceUserFrame 1.3.6.1.4.1.2011.6.112.2.3
Indicate the frame that user is configed at. -1 indicate invalid value.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 0..255 | -1  

hwVoiceUserSlot 1.3.6.1.4.1.2011.6.112.2.4
Indicate the slot that user is configed at. -1 indicate invalid value.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 0..255 | -1  

hwVoiceUserPort 1.3.6.1.4.1.2011.6.112.2.5
Indicate the port that user is configed at. -1 indicate invalid value.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 0..255 | -1  

hwVoiceUserOperateType 1.3.6.1.4.1.2011.6.112.2.6
Indicate the port that user operate type. Options: 1. user-data-add(1) -add user data 2. user-data-delete(2) -delete user data 3. user-data-modify(3) -modify user data
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER user-data-add(1), user-data-delete(2), user-data-modify(3)  

hwVoiceUserPortNum 1.3.6.1.4.1.2011.6.112.2.7
The number of the ports send by user config change trap.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 1..12  

hwVoiceUserTsn 1.3.6.1.4.1.2011.6.112.2.8
Indicate the time slot ID that user is configed at. -1 indicate invalid value.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 0..31  

hwIASVoiceUserPortLightTrap 1.3.6.1.4.1.2011.6.112.3.1.1.0.1
This notification indicates that reset result of the SIP media gateway.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwIASVoiceUserPortPstnDataChangeTrap 1.3.6.1.4.1.2011.6.112.3.1.1.0.2
This notification indicates that data of pstn user have been changed.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwIASVoiceUserPortBraDataChangeTrap 1.3.6.1.4.1.2011.6.112.3.1.1.0.3
This notification indicates that data of bra user have been changed.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwIASVoiceUserPortPraDataChangeTrap 1.3.6.1.4.1.2011.6.112.3.1.1.0.4
This notification indicates that data of pra user have been changed.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwIASVoiceUserPortPmbsDataChangeTrap 1.3.6.1.4.1.2011.6.112.3.1.1.0.5
This notification indicates that data of pmbs user have been changed.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwIASVoiceUserPortR2DataChangeTrap 1.3.6.1.4.1.2011.6.112.3.1.1.0.6
This notification indicates that data of R2 user have been changed.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwIASVoiceUserRemoteBlockTrap 1.3.6.1.4.1.2011.6.112.3.2.1.0.1
This notification indicates that the user is remote blocked.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwIASVoiceUserUnblockTrap 1.3.6.1.4.1.2011.6.112.3.2.1.0.2
This notification indicates that the user is unblocked.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwIASVoiceUserlockedTrap 1.3.6.1.4.1.2011.6.112.3.2.1.0.3
This notification indicates that the user is locked.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwIASVoiceUserUnlockedTrap 1.3.6.1.4.1.2011.6.112.3.2.1.0.4
This notification indicates that the user is unlocked.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwIASVoiceUserTsnBlockTrap 1.3.6.1.4.1.2011.6.112.3.2.2.0.1
This notification indicates that the user time slot is blocked.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwIASVoiceUserTsnUnBlockTrap 1.3.6.1.4.1.2011.6.112.3.2.2.0.2
This notification indicates that the user time slot is unblocked.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE