HUAWEI-ENT-VOICE-PUBLIC-MIB

File: HUAWEI-ENT-VOICE-PUBLIC-MIB.mib (23051 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
HUAWEI-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
private Integer32 Unsigned32
MODULE-COMPLIANCE OBJECT-GROUP NOTIFICATION-GROUP
TEXTUAL-CONVENTION IpAddress TimeTicks
Counter32 RowStatus DisplayString
hwDatacomm

Defined Types

HwEntVoipAddressEntry  
SEQUENCE    
  hwEntVoipAddressIndex Integer32
  hwEntVoipAddressType INTEGER
  hwEntVoipInterfaceType DisplayString
  hwEntVoipInterfaceId DisplayString
  hwEntVoipMethod INTEGER
  hwEntVoipIPAddress IpAddress
  hwEntVoipAddressRowStatus RowStatus

HwEntPbxTrunkCallStaticsEntry  
SEQUENCE    
  hwEntPbxTrunkCallStaticsTrkGrpName DisplayString
  hwEntPbxTrunkCallStaticsCallType INTEGER
  hwEntPbxTrunkCallStaticsTrkGrpType INTEGER
  hwEntPbxTrunkCallStaticsAttemptCall Integer32
  hwEntPbxTrunkCallStaticsAlertingCall Integer32
  hwEntPbxTrunkCallStaticsAnswerCall Integer32
  hwEntPbxTrunkCallStaticsTotalCallTime Integer32
  hwEntPbxTrunkCallStaticsTrunkNum Integer32
  hwEntPbxTrunkCallStaticsTrunkOccupyPer Integer32

Defined Values

hwEntVoicePublicMIB 1.3.6.1.4.1.2011.5.25.249
Huawei VOICE PUBLIC mib.
MODULE-IDENTITY    

hwEntSysParaConfigTable 1.3.6.1.4.1.2011.5.25.249.1
OBJECT IDENTIFIER    

hwEntSysParaCountry 1.3.6.1.4.1.2011.5.25.249.1.1
System parameter of country. Options: chinaMainland(1) - China mainland chinaHongkong(2) - China Hongkong brazil(3) - Brazil egypt(4) - Egypt singapore(5) - Singapore thailand(6) - Thailand france(7) - France britainMsfuk(8) - Britain msfuk britainEtsi(9) - Britain etsi bulgaria(10) - Bulgaria Default: chinaMainland(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER chinaMainland(1), chinaHongkong(2), brazil(3), egypt(4), singapore(5), thailand(6), france(7), britainMsfuk(8), britainEtsi(9), bulgaria(10)  

hwEntSysParaStopInitialRing 1.3.6.1.4.1.2011.5.25.249.1.2
System parameter of stop initial ring switch. Options: enable(1) - enable disable(2) - disable Default: enable(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hwEntSysParaMwiMode 1.3.6.1.4.1.2011.5.25.249.1.3
System parameter of mwi mode. Options: highVoltage(1) - high voltage fskWithRing(2) - fsk with ring fskWithoutRing(3) - fsk without ring Default: fskWithRing(2)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER highVoltage(1), fskWithRing(2), fskWithoutRing(3)  

hwEntSysParaFlashHookUpper 1.3.6.1.4.1.2011.5.25.249.1.4
System parameter of hooking upper threshold. (Unit: ms) Default: 350
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 50..1400  

hwEntSysParaFlashHookLower 1.3.6.1.4.1.2011.5.25.249.1.5
System parameter of hooking lower threshold. (Unit: ms) Default: 100
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 50..1400  

hwEntSysParaParkFeed 1.3.6.1.4.1.2011.5.25.249.1.6
System parameter of park feed switch. Options: enable(1) - enable disable(2) - disable Default: disable(2)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hwEntSysParaPcm 1.3.6.1.4.1.2011.5.25.249.1.7
System parameter of PCM. Options: aLaw(1) - a law uLaw(2) - u law Default: aLaw(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER aLaw(1), uLaw(2)  

hwEntSysParaRingFrequency 1.3.6.1.4.1.2011.5.25.249.1.8
System parameter of ring frequency. Options: frequency16HZ(1) - 16HZ frequency25HZ(2) - 25HZ frequency50HZ(3) - 50HZ Default: frequency25HZ(2)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER frequency16HZ(1), frequency25HZ(2), frequency50HZ(3)  

hwEntSysParaRingAcAmplitude 1.3.6.1.4.1.2011.5.25.249.1.9
System parameter of ring ac-amplitude. Options: ac65Vrms(1) - 65Vrms ac50Vrms(2) - 50Vrms Default: ac50Vrms(2)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ac65Vrms(1), ac50Vrms(2)  

hwEntSysParaGlobalDigitmap 1.3.6.1.4.1.2011.5.25.249.1.10
System parameter of global digitmap. Options: enable(1) - enable disable(2) - disable Default: enable(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hwEntSysParaSctpSendChecksum 1.3.6.1.4.1.2011.5.25.249.1.11
System parameter of sctp send checksum. Options: enable(1) - enable disable(2) - disable Default: enable(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hwEntSysParaSctpReceiveChecksum 1.3.6.1.4.1.2011.5.25.249.1.12
System parameter of sctp receive checksum. Options: enable(1) - enable disable(2) - disable Default: enable(1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

hwEntVoipAddressTable 1.3.6.1.4.1.2011.5.25.249.2
VOIP multiply IP table. The index of this table is hwEntVoipAddressIndex
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwEntVoipAddressEntry

hwEntVoipAddressEntry 1.3.6.1.4.1.2011.5.25.249.2.1
VOIP multiply IP table. The index of this entry is hwEntVoipAddressIndex
Status: current Access: not-accessible
OBJECT-TYPE    
  HwEntVoipAddressEntry  

hwEntVoipAddressIndex 1.3.6.1.4.1.2011.5.25.249.2.1.1
The index of VOIP address
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..15  

hwEntVoipAddressType 1.3.6.1.4.1.2011.5.25.249.2.1.2
The type of VOIP address. Options: signalling(1) - indicates that the type of VOIP IP is signaling. media(2) - indicates that the type of VOIP IP is media.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER signalling(1), media(2)  

hwEntVoipInterfaceType 1.3.6.1.4.1.2011.5.25.249.2.1.3
The interface type of VOIP address.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..32)  

hwEntVoipInterfaceId 1.3.6.1.4.1.2011.5.25.249.2.1.4
The interface ID of VOIP address.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..32)  

hwEntVoipMethod 1.3.6.1.4.1.2011.5.25.249.2.1.5
Static IP address or dynamic IP address name. Options: static(1) - the IP address is configured statically. dynamic(2) - the IP address is obtained dynamically.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER static(1), dynamic(2)  

hwEntVoipIPAddress 1.3.6.1.4.1.2011.5.25.249.2.1.6
IP address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

hwEntVoipAddressRowStatus 1.3.6.1.4.1.2011.5.25.249.2.1.7
Indicates the status of this conceptual row. Options: active(1) createAndGo(4) destroy(6)
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hwEntPbxStateTable 1.3.6.1.4.1.2011.5.25.249.3
OBJECT IDENTIFIER    

hwEntPbxStatePotsUserNum 1.3.6.1.4.1.2011.5.25.249.3.1
Indicates the number of pots users.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPbxStateBraUserNum 1.3.6.1.4.1.2011.5.25.249.3.2
Indicates the number of bra users.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPbxStateSipueUserNum 1.3.6.1.4.1.2011.5.25.249.3.3
Indicates the number of sipue users.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPbxAt0TrkNum 1.3.6.1.4.1.2011.5.25.249.3.4
Indicates the number of at0 trunk.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPbxPraTrkNum 1.3.6.1.4.1.2011.5.25.249.3.5
Indicates the number of pra trunk.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPbxR2TrkNum 1.3.6.1.4.1.2011.5.25.249.3.6
Indicates the number of r2 trunk.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPbxSipat0TrkNum 1.3.6.1.4.1.2011.5.25.249.3.7
Indicates the number of sipat0 trunk.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPbxSipTrkGrpNum 1.3.6.1.4.1.2011.5.25.249.3.8
Indicates the number of sip trunk group.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPbxStateOnlineUserNum 1.3.6.1.4.1.2011.5.25.249.3.9
Indicates the number of online users.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPbxStateMaxCallNum 1.3.6.1.4.1.2011.5.25.249.3.10
Indicates the max number of calls.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntSipagStateTable 1.3.6.1.4.1.2011.5.25.249.4
OBJECT IDENTIFIER    

hwEntSipagStatePotsUserNum 1.3.6.1.4.1.2011.5.25.249.4.1
Indicates the number of pots ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntSipagStateBraUserNum 1.3.6.1.4.1.2011.5.25.249.4.2
Indicates the number of bra users.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntSipagStatePraUserNum 1.3.6.1.4.1.2011.5.25.249.4.3
Indicates the number of pra users.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntSipagStateSipagNum 1.3.6.1.4.1.2011.5.25.249.4.4
Indicates the number of sipag.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntSipagStateOnlineNum 1.3.6.1.4.1.2011.5.25.249.4.5
Indicates the number of online users.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntSipagStateMaxCallNum 1.3.6.1.4.1.2011.5.25.249.4.6
Indicates the max number of calls.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntSipagStateBestFlag 1.3.6.1.4.1.2011.5.25.249.4.7
Indicates the best flag.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER running(1), shutdown(2)  

hwEntCallStaticsTable 1.3.6.1.4.1.2011.5.25.249.5
OBJECT IDENTIFIER    

hwEntCallStaticsAttemptCall 1.3.6.1.4.1.2011.5.25.249.5.1
Indicates the attempt call number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntCallStaticsAlertingCall 1.3.6.1.4.1.2011.5.25.249.5.2
Indicates the alerting call number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntCallStaticsAnswerCall 1.3.6.1.4.1.2011.5.25.249.5.3
Indicates the answer call number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntCallStaticTotalCallTime 1.3.6.1.4.1.2011.5.25.249.5.4
Indicates the total call timer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPbxTrunkCallStaticsTable 1.3.6.1.4.1.2011.5.25.249.6
Indicates the trunk call statics
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwEntPbxTrunkCallStaticsEntry

hwEntPbxTrunkCallStaticsEntry 1.3.6.1.4.1.2011.5.25.249.6.1
Indicates the trunk call statics
Status: current Access: not-accessible
OBJECT-TYPE    
  HwEntPbxTrunkCallStaticsEntry  

hwEntPbxTrunkCallStaticsTrkGrpName 1.3.6.1.4.1.2011.5.25.249.6.1.1
Indicates the trunk group name.
Status: current Access: not-accessible
OBJECT-TYPE    
  DisplayString Size(1..32)  

hwEntPbxTrunkCallStaticsCallType 1.3.6.1.4.1.2011.5.25.249.6.1.2
Indicates the call type.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER inCall(1), outCall(2), all(3)  

hwEntPbxTrunkCallStaticsTrkGrpType 1.3.6.1.4.1.2011.5.25.249.6.1.3
Indicates the trunk type.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER at0(1), sip(2), pra(3), r2(4)  

hwEntPbxTrunkCallStaticsAttemptCall 1.3.6.1.4.1.2011.5.25.249.6.1.4
Indicates the attempt call number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPbxTrunkCallStaticsAlertingCall 1.3.6.1.4.1.2011.5.25.249.6.1.5
Indicates the aletring call number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPbxTrunkCallStaticsAnswerCall 1.3.6.1.4.1.2011.5.25.249.6.1.6
Indicates the answer call number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPbxTrunkCallStaticsTotalCallTime 1.3.6.1.4.1.2011.5.25.249.6.1.7
Indicates the total call time.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPbxTrunkCallStaticsTrunkNum 1.3.6.1.4.1.2011.5.25.249.6.1.8
Indicates the trunk number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPbxTrunkCallStaticsTrunkOccupyPer 1.3.6.1.4.1.2011.5.25.249.6.1.9
Indicates the busy trunk number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntVoicePublicConformance 1.3.6.1.4.1.2011.5.25.249.7
OBJECT IDENTIFIER    

hwEntVoicePublicCompliances 1.3.6.1.4.1.2011.5.25.249.7.1
OBJECT IDENTIFIER    

hwEntVoicePublicCompliance 1.3.6.1.4.1.2011.5.25.249.7.1.1
The compliance statement for systems supporting the this module.
Status: current Access: read-only
MODULE-COMPLIANCE    

hwEntVoicePublicGroups 1.3.6.1.4.1.2011.5.25.249.7.2
OBJECT IDENTIFIER    

hwEntSysParaConfigGroup 1.3.6.1.4.1.2011.5.25.249.7.2.1
The hwEntSysParaConfig group.
Status: current Access: read-only
OBJECT-GROUP    

hwEntVoipAddressGroup 1.3.6.1.4.1.2011.5.25.249.7.2.2
The HwEntVoipAddress group.
Status: current Access: read-only
OBJECT-GROUP    

hwEntPbxStateGroup 1.3.6.1.4.1.2011.5.25.249.7.2.3
The hwEntPbxState group.
Status: current Access: read-only
OBJECT-GROUP    

hwEntSipagStateGroup 1.3.6.1.4.1.2011.5.25.249.7.2.4
The hwEntSipagState group.
Status: current Access: read-only
OBJECT-GROUP    

hwEntCallStaticsGroup 1.3.6.1.4.1.2011.5.25.249.7.2.5
The hwEntCallStatics group.
Status: current Access: read-only
OBJECT-GROUP    

hwEntPbxTrunkCallStaticsGroup 1.3.6.1.4.1.2011.5.25.249.7.2.6
The hwEntPbxTrunkCallStaticsGroup group.
Status: current Access: read-only
OBJECT-GROUP