HUAWEI-ENT-VOICE-DIAGNOSE-MIB

File: HUAWEI-ENT-VOICE-DIAGNOSE-MIB.mib (38748 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
HUAWEI-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
private Integer32 Unsigned32
MODULE-COMPLIANCE OBJECT-GROUP NOTIFICATION-GROUP
TEXTUAL-CONVENTION IpAddress TimeTicks
Counter32 RowStatus DisplayString
hwDatacomm

Defined Types

HwEntCallerEmulateEntry  
SEQUENCE    
  hwEntCallerEmulatePort Integer32
  hwEntCallerEmulateOprType INTEGER
  hwEntCallerEmulateTelno DisplayString
  hwEntCallerEmulateStatus Integer32

HwEntCalledEmulateEntry  
SEQUENCE    
  hwEntCalledEmulatePort Integer32
  hwEntCalledEmulateOprType INTEGER
  hwEntCalledEmulateStatus Integer32

HwEntCallEmulateEntry  
SEQUENCE    
  hwEntCallEmulateIndex Integer32
  hwEntCallEmulateOprType INTEGER
  hwEntCallEmulateCallerPort Integer32
  hwEntCallEmulateCalledPort Integer32
  hwEntCallEmulateCalledTelno DisplayString
  hwEntCallEmulateStatus Integer32
  hwEntCallEmulateResult Integer32

Defined Values

hwEntVoiceDiagnoseMIB 1.3.6.1.4.1.2011.5.25.314
Huawei VOICE DIAGNOSE mib.
MODULE-IDENTITY    

hwEntPotsCircuitTestTable 1.3.6.1.4.1.2011.5.25.314.1
OBJECT IDENTIFIER    

hwEntPotsCircuitTestOprType 1.3.6.1.4.1.2011.5.25.314.1.1
Indicates the operation type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER stop(1), start(2)  

hwEntPotsCircuitTestPort 1.3.6.1.4.1.2011.5.25.314.1.2
Indicates the test port. bits 31-24: reserved bits 23-16: slot index bits 15-8: subcard index bits 7-0: port index
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hwEntPotsCircuitTestBusyFlag 1.3.6.1.4.1.2011.5.25.314.1.3
Indicates the process method, when the test port is busy.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER cancel(1), busytest(2), force(3), defer(4)  

hwEntPotsCircuitTestTimeOut 1.3.6.1.4.1.2011.5.25.314.1.4
Indicates the time out of busy. (Unit: min) Default: 30
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..1440  

hwEntPotsCircuitTestTimeProc 1.3.6.1.4.1.2011.5.25.314.1.5
Indicates the process method afert time out.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noTest(1), mandatoryTest(2)  

hwEntPotsCircuitTestStatus 1.3.6.1.4.1.2011.5.25.314.1.6
Indicates the test result.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), testfail(2), portbusy(3), outoftime(4), testingAbnormal(5), testcanceled(6)  

hwEntPotsCircuitTestDigitalVoltageResult 1.3.6.1.4.1.2011.5.25.314.1.7
Indicates the test result of digital voltage.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2), notTested(3)  

hwEntPotsCircuitTestLowBatteryResult 1.3.6.1.4.1.2011.5.25.314.1.8
Indicates the test result of low battery.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2), notTested(3)  

hwEntPotsCircuitTestHighBatteryResult 1.3.6.1.4.1.2011.5.25.314.1.9
Indicates the test result of high battery.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2), notTested(3)  

hwEntPotsCircuitTestPositiveBatteryResult 1.3.6.1.4.1.2011.5.25.314.1.10
Indicates the test result of positive battery. Default: enable(1)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2), notTested(3)  

hwEntPotsCircuitTestVAGResult 1.3.6.1.4.1.2011.5.25.314.1.11
Indicates the test result of a-ground voltage.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2), notTested(3)  

hwEntPotsCircuitTestVBGResult 1.3.6.1.4.1.2011.5.25.314.1.12
Indicates the test result of b-ground voltage.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2), notTested(3)  

hwEntPotsCircuitTestLoopCurrentResult 1.3.6.1.4.1.2011.5.25.314.1.13
Indicates the test result of loop current.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2), notTested(3)  

hwEntPotsCircuitTestFeederVoltageResult 1.3.6.1.4.1.2011.5.25.314.1.14
Indicates the test result of feeder voltage.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2), notTested(3)  

hwEntPotsCircuitTestRingingCurrentVoltageResult 1.3.6.1.4.1.2011.5.25.314.1.15
Indicates the test result of ringing current voltage.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2), notTested(3)  

hwEntPotsCircuitTestRingingCurrentFrequencyResult 1.3.6.1.4.1.2011.5.25.314.1.16
Indicates the test result of ringing current frequency.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2), notTested(3)  

hwEntPotsCircuitTestFeedervoltageValue 1.3.6.1.4.1.2011.5.25.314.1.17
Indicates the feeder voltage. (Unit: v)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPotsCircuitTestRingingCurrentVoltageValue 1.3.6.1.4.1.2011.5.25.314.1.18
Indicates the ringing current voltage. (Unit: v)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPotsCircuitTestLoopCurrentValue 1.3.6.1.4.1.2011.5.25.314.1.19
Indicates the loop current. (Unit: mA)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPotsLoopTestTable 1.3.6.1.4.1.2011.5.25.314.2
OBJECT IDENTIFIER    

hwEntPotsLoopTestOprType 1.3.6.1.4.1.2011.5.25.314.2.1
Indicates the operation type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER stop(1), start(2)  

hwEntPotsLoopTestPort 1.3.6.1.4.1.2011.5.25.314.2.2
Indicates the test port. bits 31-24: reserved bits 23-16: slot index bits 15-8: subcard index bits 7-0: port index
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hwEntPotsLoopTestBusyFlag 1.3.6.1.4.1.2011.5.25.314.2.3
Indicates the process method, when the test port is busy.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER cancel(1), busytest(2), force(3), defer(4)  

hwEntPotsLoopTestTimeOut 1.3.6.1.4.1.2011.5.25.314.2.4
Indicates the time out of busy. (Unit: min) Default: 30
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..1440  

hwEntPotsLoopTestTimeProc 1.3.6.1.4.1.2011.5.25.314.2.5
Indicates the process method, after the time out of busy.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noTest(1), mandatoryTest(2)  

hwEntPotsLoopTestVoltage 1.3.6.1.4.1.2011.5.25.314.2.6
Indicates the test result of voltage.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noSelect(1), select(2)  

hwEntPotsLoopTestResistance 1.3.6.1.4.1.2011.5.25.314.2.7
Indicates the test result of resistance.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noSelect(1), select(2)  

hwEntPotsLoopTestCapacitance 1.3.6.1.4.1.2011.5.25.314.2.8
Indicates the test result of capacitance.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noSelect(1), select(2)  

hwEntPotsLoopTestLoopResistance 1.3.6.1.4.1.2011.5.25.314.2.9
Indicates the test result of loop resistance.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noSelect(1), select(2)  

hwEntPotsLoopTestInverseResistance 1.3.6.1.4.1.2011.5.25.314.2.10
Indicates the test result of inverse resistance.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noSelect(1), select(2)  

hwEntPotsLoopTestStatus 1.3.6.1.4.1.2011.5.25.314.2.11
Indicates the test status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), testFail(2), portBusy(3), outofTime(4), testingAbnormal(5), testCanceled(6)  

hwEntPotsLoopTestConclusion 1.3.6.1.4.1.2011.5.25.314.2.12
Indicates the test conclusion.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..28  

hwEntPotsLoopTestACAGnd 1.3.6.1.4.1.2011.5.25.314.2.13
Indicates the a-ground AC voltage. (Unit: v)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPotsLoopTestACBGnd 1.3.6.1.4.1.2011.5.25.314.2.14
Indicates the b-ground AC voltage. (Unit: v)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPotsLoopTestACAB 1.3.6.1.4.1.2011.5.25.314.2.15
Indicates the a-b AC voltage. (Unit: v)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPotsLoopTestDCAGnd 1.3.6.1.4.1.2011.5.25.314.2.16
Indicates the a-ground DC voltage. (Unit: v)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPotsLoopTestDCBGnd 1.3.6.1.4.1.2011.5.25.314.2.17
Indicates the b-ground DC voltage. (Unit: v)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPotsLoopTestDCAB 1.3.6.1.4.1.2011.5.25.314.2.18
Indicates the a-b DC voltage. (Unit: v)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPotsLoopTestRAGnd 1.3.6.1.4.1.2011.5.25.314.2.19
Indicates the a-ground resistance. (Unit: )
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPotsLoopTestRBGnd 1.3.6.1.4.1.2011.5.25.314.2.20
Indicates the b-ground resistance. (Unit: )
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPotsLoopTestRAB 1.3.6.1.4.1.2011.5.25.314.2.21
Indicates the a-b resistance. (Unit: )
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPotsLoopTestCAGnd 1.3.6.1.4.1.2011.5.25.314.2.22
Indicates the a-ground capacitance. (Unit: F)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPotsLoopTestCBGnd 1.3.6.1.4.1.2011.5.25.314.2.23
Indicates the b-ground capacitance. (Unit: F)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPotsLoopTestCAB 1.3.6.1.4.1.2011.5.25.314.2.24
Indicates the a-b capacitance. (Unit: F)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPotsLoopTestLR 1.3.6.1.4.1.2011.5.25.314.2.25
Indicates the loop resistance. (Unit: )
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPotsLoopTestRRevPole 1.3.6.1.4.1.2011.5.25.314.2.26
Indicates the rev pole resistance. (Unit: )
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntPotsLoopTestMSocket 1.3.6.1.4.1.2011.5.25.314.2.27
Indicates the MSocket.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notConnected(1), connected(2)  

hwEntPotsPathTestTable 1.3.6.1.4.1.2011.5.25.314.3
OBJECT IDENTIFIER    

hwEntPotsPathTestPort 1.3.6.1.4.1.2011.5.25.314.3.1
Indicates the test port. bits 31-24: reserved bits 23-16: slot index bits 15-8: subcard index bits 7-0: port index
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hwEntPotsPathTestMode 1.3.6.1.4.1.2011.5.25.314.3.2
Indicates the test type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER hardware(1), business(2)  

hwEntPotsPathTestAssistPort 1.3.6.1.4.1.2011.5.25.314.3.3
Indicates the assist port. bits 31-24: reserved bits 23-16: slot index bits 15-8: subcard index bits 7-0: port index
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hwEntPotsPathTestDestTelno 1.3.6.1.4.1.2011.5.25.314.3.4
Indicates the destination telephone number.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..32)  

hwEntPotsPathTestOprType 1.3.6.1.4.1.2011.5.25.314.3.5
Indicates the operation type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER stop(1), start(2)  

hwEntPotsPathTestResult 1.3.6.1.4.1.2011.5.25.314.3.6
Indicates the test result.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..23  

hwEntLineTestConfigTable 1.3.6.1.4.1.2011.5.25.314.4
OBJECT IDENTIFIER    

hwEntLineTestACVolGate 1.3.6.1.4.1.2011.5.25.314.4.1
Indicates the AC voltage gate. (Unit: v) Default: 55
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

hwEntLineTestDCVolGate 1.3.6.1.4.1.2011.5.25.314.4.2
Indicates the DC voltage gate. (Unit: v) Default: 40
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

hwEntLineTestResistGate 1.3.6.1.4.1.2011.5.25.314.4.3
Indicates the resistance gate. (Unit: ) Default: 20000
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

hwEntLineTestOffHookRABLow 1.3.6.1.4.1.2011.5.25.314.4.4
Indicates the low limit of a-b resistance in off hook. (Unit: ) Default: 100
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

hwEntLineTestOffHookRABUp 1.3.6.1.4.1.2011.5.25.314.4.5
Indicates the up limit of a-b resistance in off hook. (Unit: ) Default: 100000
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

hwEntLineTestLRLow 1.3.6.1.4.1.2011.5.25.314.4.6
Indicates the low limit of loop resistance. (Unit: ) Default: 100
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

hwEntLineTestLRLUp 1.3.6.1.4.1.2011.5.25.314.4.7
Indicates the up limit of loop resistance. (Unit: ) Default: 2000
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

hwEntLineTestSelfMixRAB 1.3.6.1.4.1.2011.5.25.314.4.8
Indicates the a-b resistance of mix. (Unit: ) Default: 2000
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

hwEntLineTestInsRABLow 1.3.6.1.4.1.2011.5.25.314.4.9
Indicates the low limit of a-b resistance. (Unit: ) Default: 2000
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

hwEntLineTestInsRABUp 1.3.6.1.4.1.2011.5.25.314.4.10
Indicates the up limit of a-b resistance. (Unit: ) Default: 20000
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

hwEntLineTestCapACUpGate 1.3.6.1.4.1.2011.5.25.314.4.11
Indicates the ground capacitance up gate. (Unit: nF) Default: 700
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

hwEntLineTestCapGroundNormalGate 1.3.6.1.4.1.2011.5.25.314.4.12
Indicates the ground capacitance normal gate. (Unit: nF) Default: 200
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

hwEntLineTestCapACLowGate 1.3.6.1.4.1.2011.5.25.314.4.13
Indicates the ground capacitance low gate. (Unit: nF) Default: 350
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

hwEntLineTestCapGroundNormalSmallGate 1.3.6.1.4.1.2011.5.25.314.4.14
Indicates the ground capacitance normal small gate. (Unit: nF) Default: 350
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

hwEntLineTestAdjustCAB 1.3.6.1.4.1.2011.5.25.314.4.15
Indicates the a-b adjest capacitance. (Unit: nF)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..10000000  

hwEntLineTestAdjustCAG 1.3.6.1.4.1.2011.5.25.314.4.16
Indicates the a-ground adjest capacitance. (Unit: nF)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..10000000  

hwEntLineTestAdjustCBG 1.3.6.1.4.1.2011.5.25.314.4.17
Indicates the b-ground adjest capacitance. (Unit: nF)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..10000000  

hwEntLineTestAdjustRAB 1.3.6.1.4.1.2011.5.25.314.4.18
Indicates the a-b adjest resistance. (Unit: )
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..10000000  

hwEntLineTestAdjustCutPort 1.3.6.1.4.1.2011.5.25.314.4.19
Indicates the adjest cut port. bits 31-24: reserved bits 23-16: slot index bits 15-8: subcard index bits 7-0: port index
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..10000000  

hwEntLineTestAdjustSelfMixPort 1.3.6.1.4.1.2011.5.25.314.4.20
Indicates the adjest self mix port. bits 31-24: reserved bits 23-16: slot index bits 15-8: subcard index bits 7-0: port index
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..10000000  

hwEntCallerEmulateTable 1.3.6.1.4.1.2011.5.25.314.5
A list of hwEntCallerEmulateEntry objects.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwEntCallerEmulateEntry

hwEntCallerEmulateEntry 1.3.6.1.4.1.2011.5.25.314.5.1
A list of hwEntCallerEmulateEntry objects.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwEntCallerEmulateEntry  

hwEntCallerEmulatePort 1.3.6.1.4.1.2011.5.25.314.5.1.1
Indicates the caller port. bits 31-24: reserved bits 23-16: slot index bits 15-8: subcard index bits 7-0: port index
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntCallerEmulateOprType 1.3.6.1.4.1.2011.5.25.314.5.1.2
Indicates the operation type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER stop(1), start(2)  

hwEntCallerEmulateTelno 1.3.6.1.4.1.2011.5.25.314.5.1.3
Indicates the telephone number.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..32)  

hwEntCallerEmulateStatus 1.3.6.1.4.1.2011.5.25.314.5.1.4
Indicates the test status.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 19..21  

hwEntCalledEmulateTable 1.3.6.1.4.1.2011.5.25.314.6
A list of hwEntCalledEmulateEntry objects.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwEntCalledEmulateEntry

hwEntCalledEmulateEntry 1.3.6.1.4.1.2011.5.25.314.6.1
A list of hwEntCalledEmulateEntry objects.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwEntCalledEmulateEntry  

hwEntCalledEmulatePort 1.3.6.1.4.1.2011.5.25.314.6.1.1
Indicates the caller port. bits 31-24: reserved bits 23-16: slot index bits 15-8: subcard index bits 7-0: port index
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntCalledEmulateOprType 1.3.6.1.4.1.2011.5.25.314.6.1.2
Indicates the operation type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER stop(1), start(2)  

hwEntCalledEmulateStatus 1.3.6.1.4.1.2011.5.25.314.6.1.3
Indicates the test status.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 17..19  

hwEntCallEmulateTable 1.3.6.1.4.1.2011.5.25.314.7
A list of hwEntCallEmulateEntry objects.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwEntCallEmulateEntry

hwEntCallEmulateEntry 1.3.6.1.4.1.2011.5.25.314.7.1
A list of hwEntCallEmulateEntry objects.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwEntCallEmulateEntry  

hwEntCallEmulateIndex 1.3.6.1.4.1.2011.5.25.314.7.1.1
Indicates the test index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwEntCallEmulateOprType 1.3.6.1.4.1.2011.5.25.314.7.1.2
Indicates the operation type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER stop(1), start(2)  

hwEntCallEmulateCallerPort 1.3.6.1.4.1.2011.5.25.314.7.1.3
Indicates the calller port.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hwEntCallEmulateCalledPort 1.3.6.1.4.1.2011.5.25.314.7.1.4
Indicates the callled port.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hwEntCallEmulateCalledTelno 1.3.6.1.4.1.2011.5.25.314.7.1.5
Indicates the telephone number.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..32)  

hwEntCallEmulateStatus 1.3.6.1.4.1.2011.5.25.314.7.1.6
Indicates the call status.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..6  

hwEntCallEmulateResult 1.3.6.1.4.1.2011.5.25.314.7.1.7
Indicates the call result.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..6  

hwEntVoiceTestTraps 1.3.6.1.4.1.2011.5.25.314.8
OBJECT IDENTIFIER    

hwEntPotsCircuitTestTrap 1.3.6.1.4.1.2011.5.25.314.8.1
circuit test result.
Status: current Access: read-only
NOTIFICATION-TYPE    

hwEntPotsLoopTestTrap 1.3.6.1.4.1.2011.5.25.314.8.2
Loop test result.
Status: current Access: read-only
NOTIFICATION-TYPE    

hwEntPotsPathTestTrap 1.3.6.1.4.1.2011.5.25.314.8.3
Path test result.
Status: current Access: read-only
NOTIFICATION-TYPE    

hwEntCallEmulateTrap 1.3.6.1.4.1.2011.5.25.314.8.4
Call emulate result.
Status: current Access: read-only
NOTIFICATION-TYPE    

hwEntVoiceDiagnoseConformance 1.3.6.1.4.1.2011.5.25.314.9
OBJECT IDENTIFIER    

hwEntVoiceDiagnoseCompliances 1.3.6.1.4.1.2011.5.25.314.9.1
OBJECT IDENTIFIER    

hwEntVoiceDiagnoseCompliance 1.3.6.1.4.1.2011.5.25.314.9.1.1
The compliance statement for systems supporting the this module.
Status: current Access: read-only
MODULE-COMPLIANCE    

hwEntVoiceDiagnoseGroups 1.3.6.1.4.1.2011.5.25.314.9.2
OBJECT IDENTIFIER    

hwEntPotsCircuitTestGroup 1.3.6.1.4.1.2011.5.25.314.9.2.1
The hwEntPotsCircuitTest group.
Status: current Access: read-only
OBJECT-GROUP    

hwEntPotsLoopTestGroup 1.3.6.1.4.1.2011.5.25.314.9.2.2
The hwEntPotsLoopTest group.
Status: current Access: read-only
OBJECT-GROUP    

hwEntPotsPathTestGroup 1.3.6.1.4.1.2011.5.25.314.9.2.3
The hwEntPotsPathTest group.
Status: current Access: read-only
OBJECT-GROUP    

hwEntLineTestConfigGroup 1.3.6.1.4.1.2011.5.25.314.9.2.4
The EntLineTest Config group.
Status: current Access: read-only
OBJECT-GROUP    

hwEntCallerEmulateGroup 1.3.6.1.4.1.2011.5.25.314.9.2.5
The EntCaller Emulate Group.
Status: current Access: read-only
OBJECT-GROUP    

hwEntCalledEmulateGroup 1.3.6.1.4.1.2011.5.25.314.9.2.6
The EntCalled Emulate group.
Status: current Access: read-only
OBJECT-GROUP    

hwEntCallEmulateGroup 1.3.6.1.4.1.2011.5.25.314.9.2.7
The EntCallEmulate group.
Status: current Access: read-only
OBJECT-GROUP    

hwEntVoiceTestTrapDefineGroup 1.3.6.1.4.1.2011.5.25.314.9.2.8
The EntVoiceTest Trap group.
Status: current Access: read-only
NOTIFICATION-GROUP