HIRSCHMANN-GENERIC-ERROR-MIB

File: HIRSCHMANN-GENERIC-ERROR-MIB.mib (5723 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC

Imported symbols

MODULE-IDENTITY OBJECT-TYPE OBJECT-IDENTITY
enterprises Integer32 TEXTUAL-CONVENTION
DisplayString AutonomousType TestAndIncr

Defined Values

hirschmann 1.3.6.1.4.1.248
OBJECT IDENTIFIER    

hmMgmtSEEErrorIDGroup 1.3.6.1.4.1.248.16.2
OBJECT IDENTIFIER    

hmMgmtSEInfoIDGroup 1.3.6.1.4.1.248.16.3
OBJECT IDENTIFIER    

hmRedundancyConflict 1.3.6.1.4.1.248.16.2.1
Conflict Redundancy Protocols: Cannot enable {0} because of enabled {1}.
Status: current Access: read-only
OBJECT-IDENTITY    

hmRedundancyConflictPort 1.3.6.1.4.1.248.16.2.2
Conflict Redundancy Protocols: Cannot enable {0} because of enabled {1} on Ring Port {2}.
Status: current Access: read-only
OBJECT-IDENTITY    

hmMaxNumExceeded 1.3.6.1.4.1.248.16.2.3
Max. number exceeded for {0}.
Status: current Access: read-only
OBJECT-IDENTITY    

hmAlreadyCreated 1.3.6.1.4.1.248.16.2.4
Instance already created.
Status: current Access: read-only
OBJECT-IDENTITY    

hmRedundancyConflictFpgaPort 1.3.6.1.4.1.248.16.2.5
Conflict Redundancy Protocols: Cannot enable {0} on configured ports.
Status: current Access: read-only
OBJECT-IDENTITY    

hmVlanUnawareConflict 1.3.6.1.4.1.248.16.2.6
Cannot enable {0} because {1} is enabled.
Status: current Access: read-only
OBJECT-IDENTITY    

hmRedundancyConflictPortShort 1.3.6.1.4.1.248.16.2.7
Cannot enable {0} on configured ports. Reason: {1}
Status: current Access: read-only
OBJECT-IDENTITY    

hmTableFullError 1.3.6.1.4.1.248.16.2.8
{0} table is full. Maximum allowed: {1}.
Status: current Access: read-only
OBJECT-IDENTITY    

hmFunctionNotUsableWithInterface 1.3.6.1.4.1.248.16.2.9
This function cannot be used with this interface.
Status: current Access: read-only
OBJECT-IDENTITY    

hmGeneralConflict 1.3.6.1.4.1.248.16.2.10
{0} conflicts with {1}. {2}.
Status: current Access: read-only
OBJECT-IDENTITY    

hmGeneralExceededRange 1.3.6.1.4.1.248.16.2.11
The {0} is exceeding the range. Maximum permissable range is {1}..{2}.
Status: current Access: read-only
OBJECT-IDENTITY    

hmRmonAlarmTableFullErrorReturn 1.3.6.1.4.1.248.16.2.100
Alarm table full. Only {0} entries are allowed.
Status: current Access: read-only
OBJECT-IDENTITY    

hmMgmtUdpPortInUse 1.3.6.1.4.1.248.16.2.200
Given UDP port is already in use.
Status: current Access: read-only
OBJECT-IDENTITY    

hmMgmtTcpPortInUse 1.3.6.1.4.1.248.16.2.201
Given TCP port is already in use.
Status: current Access: read-only
OBJECT-IDENTITY    

hmMgmtIPAddressConflictWithMgmtIP 1.3.6.1.4.1.248.16.2.202
Given IP address/netmask {0}/{1} conflicts with the management IP address/netmask.
Status: current Access: read-only
OBJECT-IDENTITY    

hmMgmtIPAddressConflictWithOobIP 1.3.6.1.4.1.248.16.2.203
Given IP address/netmask {0}/{1} conflicts with the out-of-band management IP address/netmask.
Status: current Access: read-only
OBJECT-IDENTITY    

hmMgmtIPAddressConflictWithRouterIP 1.3.6.1.4.1.248.16.2.204
Given IP address/netmask {0}/{1} conflicts with a routing interface IP address/netmask.
Status: current Access: read-only
OBJECT-IDENTITY    

hm2NetIPAddrInvalid 1.3.6.1.4.1.248.16.2.300
The {0} IP address is not valid.
Status: current Access: read-only
OBJECT-IDENTITY    

hm2NetIPAddrAndGateway 1.3.6.1.4.1.248.16.2.301
Management IP address and gateway are not on the same subnet.
Status: current Access: read-only
OBJECT-IDENTITY    

hm2NetIPAddrAndSubnet 1.3.6.1.4.1.248.16.2.302
The {0} IP address and subnet mask combination is not valid.
Status: current Access: read-only
OBJECT-IDENTITY    

hm2NetPrefixLengthInvalid 1.3.6.1.4.1.248.16.2.303
Subnet mask must have contiguous ones and be no longer than 30 bits.
Status: current Access: read-only
OBJECT-IDENTITY    

hmMgmtSEInfoValueChanged 1.3.6.1.4.1.248.16.3.1
Note: Value changed from {0} to {1}
Status: current Access: read-only
OBJECT-IDENTITY