GW-EPON-MIB

File: GW-EPON-MIB.mib (94819 bytes)

Imported modules

GWTT-SMI SNMPv2-TC SNMPv2-SMI

Imported symbols

devices RowStatus TruthValue
DisplayString MacAddress TEXTUAL-CONVENTION
DateAndTime MODULE-IDENTITY OBJECT-TYPE
Integer32 TimeTicks NOTIFICATION-TYPE
Counter32 IpAddress

Defined Types

ChassisSlotSupportType  
The value indicates the type of board this slot surpports.
TEXTUAL-CONVENTION    
  BITS sw(0), epon(1), gpon(2), get(3), geo(4), tdm(5), stm1(6), pwu48(7), pwu220(8), smb(9), gem(10), sig(11), onuEponB(12), onu6FeC(13), onu8FeD(14), onu16FeD(15), onu8PotsA(16), onu8PotsB(17), onu8FxsA(18), onu8FxsB(19), oltMain(20), olt2Epon(21), e1(22), oltE1(23), onuE1A(24), onuE1B(25), sw-6900(26), olt4epon(27), olt8epon(28), olt12epon(29), gem4ge(30), gem10ge(31), fan-6900(32), pwu-48(33), pwu-220(34), olt4epon4ge(35), pwu-220-6900m(36), pwu-48-6900m(37), fan-6900s(38), pwu-220-6900s(39), pwu-48-6900s(40)  

OnuAlarmLevelList  
Each octet within this value specifies a alarm-level of one ONU of a PON, with the first octet specifying ONU1 alarm-level, and the second octet specifying ONU2 alarm-level, etc. Per octet value is defined: '0' - null '1' - vital '2' - major '3' - minor '4' - warning '5' - clear '6' - information '7' - off-line.
TEXTUAL-CONVENTION    
  OCTET STRING  

EponDeviceType  
The value indicates the type of this device: 1 - unknown, 2 - GFA6700, 3 - GFA6100, 4 - GT811, 5 - GT831, 6 - GT831-CATV, 7 - GT812, 8 - GT813, 9 - GT881, 10 - GT861, 11 - GT891, 12 - GT810, 13 - GT863, 14 - other, 15 - GT865, 16 - GT816, 17 - GT811A, 18 - GT812A, 19 - GT831A, 20 - GT831A-CATV, 21 - GT815, 22 - GT812B, 23 - GT831B, 24 - GT866, 25 - GT811-B, 26 - GT851, 27 - GT813-B, 28 - GT862, 29 - GT892, 30 - GT835, 31 - GT831-B-CATV, 32 - GT815-B, 33 - GT871, 34 - GT871R, 35 - GD5048, 36 - GD6024, 37 - GT872, 38 - GT872P, --GT872B(deprecated) 39 - GT872R, 40 - GT873, 41 - GT873P, 42 - GT873R, 43 - GT871P, 44 - GT870, 45 - GT811-C, 46 - GT810-A, 47 - GT811-D, 96 - GFA6900M, 97 - GGA6900S, 99 - GFA6900
TEXTUAL-CONVENTION    
  Integer32  

OnuList  
Each octet within this value specifies a set of eight ONUs, with the first octet specifying ONUs ID 1 through 8, the second octet specifying ONUs ID 9 through 16, etc. Within each octet, the most significant bit represents the lowest numbered ONU ID, and the least significant bit represents the highest numbered ONU ID. Thus, each ONU of a PON is represented by a single bit within the value of this object. If the bit has a value of '1', then the ONU is registered and included in this list; if the bit has a value of '0', then the ONU is disregistered and not included.
TEXTUAL-CONVENTION    
  OCTET STRING  

ChassisSlotBoardType  
The value indicates the type of this board: null(1) - NULL, unknown(2) - Unknown, sw(3) - SW (OLT), master control and switch board. epon(4) - EPON (OLT), slave epon board. gpon(5) - GPON (OLT), slave gpon board. get(6) - GET (OLT, 4GE-TX), using category 5 UTP interface. geo(7) - GEO (OLT, 4GE-XX), using X fiber over PMT interface. tdm(8) - TDM (OLT), slave tdm board. stm1(9) - STM1 (OLT), slave stm1 board. pwu48(10) - PWR48, power board with input of -48V(DC). pwu220(11) - PWR220, power board with input of 220V(AC). smb(12) - SMB (ONU), the simple mainboard of box device. gem(13) - GEM (OLT), slave board. sig(14) - SIG (OLT), slave board. onuEponB(15) - EPON-B (ONU). onu6FeC(16) - 6FE-C (ONU), RJ45 connector. onu8FeD(17) - 8FE-D (ONU), SCSI68 connector. onu16FeD(18) - 16FE-D (ONU), SCSI68 connector. onu8PotsA(19)- 8POTS-A (ONU), RJ11 connector. onu8PotsB(20)- 8POTS-B (ONU), RJ21 connector. onu8FxsA(21) - 8FXS-A (ONU), RJ11 connector. onu8FxsB(22) - 8FXS-B (ONU), RJ21 connector. oltMain(23) - the master board of box-device OLT. olt2Epon(24) - the EPON board of box-device OLT. E1 ( 25 ) - oltE1 ( 26 ) , onuE1A ( 27 ) , onuE1B ( 28 ) , sw-6900 ( 29 ) - SW (OLT), master control and switch board of GFA6900. olt4epon ( 30 ) - EPON (OLT) , PON board with 4 PON ports. olt8epon ( 31 ) - EPON (OLT) , PON board with 8 PON ports. olt12epon ( 32 ) - EPON (OLT) , PON board with 12 PON ports and 4 GE ports. gem4ge ( 33 ) - GEM (OLT) , GEM board with 4 GE ports. gem10ge ( 34 ) - GEM (OLT) , GEM board with 1 10GE port and 4 GE ports. fan-6900 ( 35 ) - FAN (OLT) , FAN board of GFA6900. pwu-48 ( 36 ) - PWU (OLT) , 48V Power board of GFA6900 and GFA6900M. pwu-220 ( 37 ) - PWU (OLT) , 220V Power board of GFA6900. olt4epon4ge(38) - EPON (OLT) , EPON board with 4 PON ports and 4 GE ports pwu-220-6900m(39) - PWU (OLT) , 220V Power board of GFA6900M. fan-6900s(40) - FAN (OLT) , FAN board of GFA6900S. pwu-48-6900s(41) - PWU (OLT) , 48V Power board of GFA6900S. pwu-220-6900s(42) - PWU (OLT) , 220V Power board of GFA6900S.
TEXTUAL-CONVENTION    
  INTEGER null(1), unknown(2), sw(3), epon(4), gpon(5), get(6), geo(7), tdm(8), stm1(9), pwu48(10), pwu220(11), smb(12), gem(13), sig(14), onuEponB(15), onu6FeC(16), onu8FeD(17), onu16FeD(18), onu8PotsA(19), onu8PotsB(20), onu8FxsA(21), onu8FxsB(22), oltMain(23), olt2Epon(24), e1(25), oltE1(26), onuE1A(27), onuE1B(28), sw-6900(29), olt4epon(30), olt8epon(31), olt12epon(32), gem4ge(33), gem10ge(34), fan-6900(35), pwu-48(36), pwu-220(37), olt4epon4ge(38), pwu-220-6900m(39), fan-6900s(40), pwu-48-6900s(41), pwu-220-6900s(42)  

GwEponDevEntry  
SEQUENCE    
  deviceIndex Integer32
  deviceType EponDeviceType
  deviceName DisplayString
  deviceDescription DisplayString
  deviceLocation DisplayString
  deviceVendor DisplayString
  deviceFirmWareVersion DisplayString
  deviceSoftWareVersion DisplayString
  deviceHardWareVersion DisplayString
  deviceOperStatus INTEGER
  deviceAlarmStatus INTEGER
  deviceMacAddress MacAddress
  deviceLastChange TimeTicks
  deviceReset INTEGER
  deviceEntLogicalIndex Integer32
  deviceEntLogicalCommunity DisplayString
  deviceOnuTestDistance Integer32
  deviceUpTime TimeTicks
  deviceStpEnable INTEGER
  deviceChipsetVendor DisplayString
  deviceChipsetMode Integer32
  deviceChipsetRevision DisplayString
  deviceChipsetDate DisplayString
  deviceCapPortDesc DisplayString
  deviceCapEthPortNum Integer32
  deviceCapIadPotsPortNum Integer32
  deviceCapE1PortNum Integer32
  deviceCapUQueueTotal Integer32
  deviceCapUQueuePort Integer32
  deviceCapDQueueTotal Integer32
  deviceCapDQueuePort Integer32
  deviceCapBattery INTEGER
  deviceMulticastSwitch INTEGER
  deviceSystemTime DateAndTime
  deviceRestartupTime DateAndTime
  deviceTrafficServiceStatus INTEGER
  deviceAlarmMask BITS
  deviceModel DisplayString
  deviceMulticastFastLeaveAbility BITS
  deviceMulticastFastLeaveOperState INTEGER
  deviceMulticastFastLeaveAdminState INTEGER
  onuMacTableAlarmThreshold Integer32
  onuMacNumbers Integer32

GwEponBoardEntry  
SEQUENCE    
  boardIndex Integer32
  curBoardType ChassisSlotBoardType
  boardDescription DisplayString
  boardActMode INTEGER
  boardOperStatus INTEGER
  boardAlarmLevel INTEGER
  boardLastChangeTime TimeTicks
  boardSupprotType ChassisSlotSupportType
  boardReset INTEGER
  boardTemperature Integer32
  boardEntLogicalIndex Integer32
  boardEntLogicalCommunity DisplayString
  boardSoftwareVersion DisplayString
  boardFirmwareVersion DisplayString
  boardBootVersion DisplayString
  boardHardwareVersion DisplayString
  boardManufactureDate DisplayString
  boardSerialNo DisplayString
  boardCpuUsage Integer32
  boardMemoryUsage Integer32
  boardHasSnmpAgent INTEGER
  boardSnmpAgentIpAddr IpAddress
  boardSnmpAgentReadCommunity DisplayString
  boardSnmpAgentWriteCommunity DisplayString
  boardTemperatureHighThresholds Integer32
  boardCpuUsageThresholds Integer32
  boardMemoryUsageThresholds Integer32
  boardMemorySize Integer32
  boardTemperatureLowThresholds Integer32
  boardAdminStatus INTEGER

PonPortEntry  
SEQUENCE    
  ponPortIndex Integer32
  ponPortIfIndex Integer32
  ponPortDot1dBasePort Integer32
  ponPortPartnerDev Integer32
  ponPortPartnerBrd Integer32
  ponPortPartnerPort Integer32
  ponPortProtectionDev Integer32
  ponPortProtectionBrd Integer32
  ponPortProtectionPort Integer32
  ponPortType INTEGER
  ponPortMaxOnu Integer32
  ponPortCurrOnu Integer32
  ponPortOperStatus INTEGER
  ponPortAlarmStatus BITS
  ponPortAlarmMask BITS
  ponPortMaxBW Integer32
  ponPortActBW Integer32
  ponPortRemainBW Integer32
  ponPortApsCtrl INTEGER
  ponPortApsStatus INTEGER
  ponPortEncryptSet INTEGER
  ponPortOnuLpbCtrl INTEGER
  ponPortOnuLpbSource INTEGER
  ponPortOnuLpbTime Integer32
  ponPortOnuLpbTxFrms Counter32
  ponPortOnuLpbRxFrms Counter32
  ponEntLogicalIndex Integer32
  ponEntLogicalCommunity DisplayString
  ponPortLinkedOnuCounter Integer32
  ponPortAdminStatus INTEGER
  ponPortReset INTEGER
  ponPortWindowRange INTEGER
  ponPortDownlinkPolicingEbl INTEGER
  ponPortAllOnuAlmLevel OnuAlarmLevelList

PonOnuMapEntry  
SEQUENCE    
  mappingOnuIndex Integer32
  onuDevIndex Integer32
  onuName DisplayString

PonPerfMonEntry  
SEQUENCE    
  ponPerfBER Counter32
  ponPerfFER Counter32
  ponPerfBerAlmEnable INTEGER
  ponPerfFerAlmEnable INTEGER
  ponPerfUpBandwidth Counter32
  ponPerfDownBandwidth Counter32

PonHisCtrlEntry  
SEQUENCE    
  ponHis15MinuteEnable INTEGER
  ponHis24HourEnable INTEGER

OnuAuthEntry  
SEQUENCE    
  eponBoardIndex Integer32
  eponPonPortIndex Integer32
  onuAuthIndex Integer32
  onuAuthMacAddress MacAddress
  onuAuthRowStatus RowStatus

OnuAuthModeEntry  
SEQUENCE    
  onuAuthModeBrdIdx Integer32
  onuAuthModePonIdx Integer32
  onuAuthMode INTEGER
  onuAuthEnableForPon INTEGER
  onuAuthEntryReorganize INTEGER

OnuAuthLoidEntry  
SEQUENCE    
  onuAuthLoidBrdIdx Integer32
  onuAuthLoidPonIdx Integer32
  onuAuthLoidIdx Integer32
  onuAuthLoid DisplayString
  onuAuthLoidPassword DisplayString
  onuAuthLoidDevIdx Integer32
  onuAuthLoidRowStatus RowStatus

OnuAuth1Entry  
SEQUENCE    
  eponUnauthenticatedBoardIndex Integer32
  eponUnauthenticatedPonPortIndex Integer32
  onuUnauthenticatedIndex Integer32
  onuUnauthenticatedMacAddress MacAddress

PonLlidEntry  
SEQUENCE    
  ponLlidIndex Integer32
  ponLlidType INTEGER
  ponLlidOltBoard Integer32
  ponLlidOltPort Integer32
  ponLlidOltPortIfIndex Integer32
  ponLlidOnuPortIfIndex Integer32
  ponLlidOnuBoard Integer32
  ponLlidOnuPort Integer32
  ponLlidLLID Integer32
  ponLlidIfIndex Integer32
  ponLlidUpFixedBW Integer32
  ponLlidDownFixedBW Integer32
  ponLlidDesc DisplayString
  ponLlidSurportMacNum Integer32
  ponLlidOnuMacAddress MacAddress
  ponLlidRowStatus RowStatus
  ponLlidUpBWClass Integer32
  ponLlidUpDelay INTEGER
  ponLlidUpAssuredBW Integer32
  ponLlidUpBesteffortBW Integer32
  ponLlidDownBWClass Integer32
  ponLlidDownDelay INTEGER
  ponLlidDownAssuredBW Integer32
  ponLlidDownBesteffortBW Integer32
  ponLlidCtcFecAbility INTEGER
  ponLlidCtcFecMode INTEGER
  ponLlidCtcEncrypCtrl INTEGER
  ponLlidCtcDbaQueSetNum Integer32
  ponLlidCtcDbaQueSetCfgStatus INTEGER

PonLlidCtcDbaQueSetEntry  
SEQUENCE    
  ponLlidCtcDbaQueSetIndex Integer32
  ponLlidCtcDbaReportBitmap BITS
  ponLlidCtcDbaQueue0Threshold Integer32
  ponLlidCtcDbaQueue1Threshold Integer32
  ponLlidCtcDbaQueue2Threshold Integer32
  ponLlidCtcDbaQueue3Threshold Integer32
  ponLlidCtcDbaQueue4Threshold Integer32
  ponLlidCtcDbaQueue5Threshold Integer32
  ponLlidCtcDbaQueue6Threshold Integer32
  ponLlidCtcDbaQueue7Threshold Integer32

Defined Values

gwEponMib 1.3.6.1.4.1.10072.2.20
EPON private MIB information definitions
MODULE-IDENTITY    

gwEponMibObjects 1.3.6.1.4.1.10072.2.20.1
OBJECT IDENTIFIER    

gwEponCfgGroup 1.3.6.1.4.1.10072.2.20.1.1
OBJECT IDENTIFIER    

gwEponDevice 1.3.6.1.4.1.10072.2.20.1.1.1
OBJECT IDENTIFIER    

gwEponBoard 1.3.6.1.4.1.10072.2.20.1.1.2
OBJECT IDENTIFIER    

gwEponPon 1.3.6.1.4.1.10072.2.20.1.1.3
OBJECT IDENTIFIER    

gwEponPonOnuAuth 1.3.6.1.4.1.10072.2.20.1.1.4
OBJECT IDENTIFIER    

gwEponLlid 1.3.6.1.4.1.10072.2.20.1.1.5
OBJECT IDENTIFIER    

gwDevTrapGroup 1.3.6.1.4.1.10072.2.20.1.1.6
OBJECT IDENTIFIER    

gwAlarmLevelGroup 1.3.6.1.4.1.10072.2.20.1.1.7
OBJECT IDENTIFIER    

gwConsoleCfgGroup 1.3.6.1.4.1.10072.2.20.1.1.8
OBJECT IDENTIFIER    

gwEponDevTable 1.3.6.1.4.1.10072.2.20.1.1.1.1
Table of device informations
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GwEponDevEntry

gwEponDevEntry 1.3.6.1.4.1.10072.2.20.1.1.1.1.1
An entry in the table, containing properties and some descriptions
Status: current Access: not-accessible
OBJECT-TYPE    
  GwEponDevEntry  

deviceIndex 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.1
Index of device
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

deviceType 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.2
The value indicates the type of this device
Status: current Access: read-only
OBJECT-TYPE    
  EponDeviceType  

deviceName 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.3
A string indicates or configure device name
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

deviceDescription 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.4
Description for this device
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

deviceLocation 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.5
A string indicates and configure the device location
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

deviceVendor 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.6
A string indicates the vendor
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

deviceFirmWareVersion 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.7
The value indicates the version of firmware
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(20)  

deviceSoftWareVersion 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.8
The value indicates the version of software
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(20)  

deviceHardWareVersion 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.9
The value indicates the version of PCB
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(20)  

deviceOperStatus 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.10
The current operational state of the device, 'down(2)' indicates that the ONU is off-line. 'dormant(4)' indicates the device is waiting for external actions (such as no bandwidth for any service), 'powerDown(5)' indicates the device is power down or dying gasp.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), unknown(3), dormant(4), powerDown(5)  

deviceAlarmStatus 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.11
The value indicates alarm status for this device, it means unique alarm occur that unique bit is set '1', on the other hand, unique bit is set 0 while this alarm is cleared.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER vital(1), major(2), minor(3), warning(4), clear(5)  

deviceMacAddress 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.12
The value indicates and confgure device MAC address
Status: current Access: read-write
OBJECT-TYPE    
  MacAddress Size(6)  

deviceLastChange 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.15
the last time for this device change
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

deviceReset 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.16
Description
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noop(1), reset(2)  

deviceEntLogicalIndex 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.17
The value of this object uniquely identifies the logical entity. The value should be a small positive integer; index values for different logical entities are are not necessarily contiguous.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2147483647  

deviceEntLogicalCommunity 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.18
An SNMPv1 or SNMPv2C community-string which can be used to access detailed management information for this logical entity. The agent should allow read access with this community string (to an appropriate subset of all managed objects) and may also return a community string based on the privileges of the request used to read this object. Note that an agent may return a community string with read-only privileges, even if this object is accessed with a read- write community string. However, the agent must take care not to return a community string which allows more privileges than the community string used to access this object. A compliant SNMP agent may wish to conserve naming scopes by representing multiple logical entities in a single 'default' naming scope. This is possible when the logical entities represented by the same value of entLogicalCommunity have no object instances in common. For example, 'bridge1' and 'repeater1' may be part of the main naming scope, but at least one additional community string is needed to represent 'bridge2' and 'repeater2'. Logical entities 'bridge1' and 'repeater1' would be represented by sysOREntries associated with the 'default' naming scope. For agents not accessible via SNMPv1 or SNMPv2C, the value of this object is the empty string. This object may also contain an empty string if a community string has not yet been assigned by the agent, or no community string with suitable access rights can be returned for a particular SNMP request. Note that this object is deprecated. Agents which implement SNMPv3 access should use the entLogicalContextEngineID and entLogicalContextName objects to identify the context associated with each logical entity. SNMPv3 agents may return a zero-length string for this object, or may continue to return a community string (e.g., tri-lingual agent support).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..20)  

deviceOnuTestDistance 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.19
the distance between OLT and unique ONU, unit:meter
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

deviceUpTime 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.20
The value of this object uniquely identifies up time about this device.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

deviceStpEnable 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.21
OLT or ONU spanning tree contral, enable(1)- enable the spanning tree protocol, disable(2)- disable the spanning tree protocol.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

deviceChipsetVendor 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.22
PON chipset vendor ID
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

deviceChipsetMode 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.23
PON chipset type
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

deviceChipsetRevision 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.24
PON chipset revision
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

deviceChipsetDate 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.25
PON chipset design date
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

deviceCapPortDesc 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.26
Port capabilities description, include GE/FE/E1/POTS etc.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

deviceCapEthPortNum 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.27
Number of ethernet port supported
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

deviceCapIadPotsPortNum 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.28
Number of POTS port of IAD supported
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

deviceCapE1PortNum 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.29
Number of E1 port supported
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

deviceCapUQueueTotal 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.30
Number of upstream queues
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

deviceCapUQueuePort 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.31
Maximum queues per port upstream
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

deviceCapDQueueTotal 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.32
Number of downstream queues
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

deviceCapDQueuePort 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.33
Maximum queues per port downstream
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

deviceCapBattery 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.34
Battery Backup
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

deviceMulticastSwitch 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.35
ONU multicast switch
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER snooping(1), ctc(2)  

deviceSystemTime 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.36
Current system clock-time. OCTET-STRING consisting of eleven octets whose contents are defined by RFC2579.
Status: current Access: read-write
OBJECT-TYPE    
  DateAndTime  

deviceRestartupTime 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.37
The time of device(OLT or ONU) restartup-time. OCTET-STRING consisting of eleven octets whose contents are defined by RFC2579.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

deviceTrafficServiceStatus 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.38
ONU traffic service state. 'enable(1)' indicates the traffic is in-service. 'disable(2)' indicates the traffic is out of service, but is still registered.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

deviceAlarmMask 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.39
.
Status: current Access: read-write
OBJECT-TYPE    
  BITS power(0), fan(1), cpu(2), temperature(3), register(4), present(5), ethlink(6), ethfer(7), ethflr(8), ethti(9), ethloop(10), ponber(11), ponfer(12), ponabnormal(13), ponaps(14), ponlink(15), onuLaserAlwayOn(16), onuOpticalPowerLow(17), onuOpticalPowerHigh(18), ponLOS(19)  

deviceModel 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.40
.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

deviceMulticastFastLeaveAbility 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.41
Fast Leave Mode: If the bit value of 'ctc(0)' is 0, the mode is CTC and non-fast-leave function, if the bit value of 'ctc(0)' is 1, the mode is CTC and fast-leave function; If the bit value of 'snooping(1)' is 0, the mode is snooping and non-fast-leave function, If the bit value of 'snooping(1)' is 1, the mode is snooping and fast-leave function.
Status: current Access: read-only
OBJECT-TYPE    
  BITS ctc(0), snooping(1)  

deviceMulticastFastLeaveOperState 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.42
Fast Leave Function is active or deactive
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), deactive(2)  

deviceMulticastFastLeaveAdminState 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.43
active or deactivate Fast Leave Function
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER active(1), deactive(2)  

onuMacTableAlarmThreshold 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.44
onu MAC table alarm threshold
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

onuMacNumbers 1.3.6.1.4.1.10072.2.20.1.1.1.1.1.45
show onu actual mac number
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

gwEponBoardTable 1.3.6.1.4.1.10072.2.20.1.1.2.1
table of board informations
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GwEponBoardEntry

gwEponBoardEntry 1.3.6.1.4.1.10072.2.20.1.1.2.1.1
An entry in the table, containig status and configrue information about boards
Status: current Access: not-accessible
OBJECT-TYPE    
  GwEponBoardEntry  

boardIndex 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.1
index of boards in unique device which is specified by 'deviceIndex'
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

curBoardType 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.2
The value indicates the type of this board.
Status: current Access: read-only
OBJECT-TYPE    
  ChassisSlotBoardType  

boardDescription 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.3
The value indicates and confgure board description
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

boardActMode 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.4
The value indicates acting mode of unique board
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER master-active(1), master-redundancy(2), slave(3), unknown(4)  

boardOperStatus 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.5
The Value indicates board operating status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER null(1), initing(2), upgrating(3), running(4), exception(5)  

boardAlarmLevel 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.6
The value indicates alarm level for unique board
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER vital(1), major(2), minor(3), warning(4), noAlarm(5)  

boardLastChangeTime 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.7
the time of last change about this board
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

boardSupprotType 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.8
The value indicates the type of board this slot surpports.
Status: current Access: read-only
OBJECT-TYPE    
  ChassisSlotSupportType  

boardReset 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.9
The value of this object determines whether reset this board. 'noop(1)' - only read value. 'reset(2)' - only write value, if the active master board is resetted, and another master board is running, then, the two boards will be switchover.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noop(1), reset(2)  

boardTemperature 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.10
The value indicates the temperature of this board
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

boardEntLogicalIndex 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.11
The value of this object uniquely identifies the logical entity. The value should be a small positive integer; index values for different logical entities are are not necessarily contiguous.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2147483647  

boardEntLogicalCommunity 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.12
An SNMPv1 or SNMPv2C community-string which can be used to access detailed management information for this logical entity. The agent should allow read access with this community string (to an appropriate subset of all managed objects) and may also return a community string based on the privileges of the request used to read this object. Note that an agent may return a community string with read-only privileges, even if this object is accessed with a read- write community string. However, the agent must take care not to return a community string which allows more privileges than the community string used to access this object. A compliant SNMP agent may wish to conserve naming scopes by representing multiple logical entities in a single 'default' naming scope. This is possible when the logical entities represented by the same value of entLogicalCommunity have no object instances in common. For example, 'bridge1' and 'repeater1' may be part of the main naming scope, but at least one additional community string is needed to represent 'bridge2' and 'repeater2'. Logical entities 'bridge1' and 'repeater1' would be represented by sysOREntries associated with the 'default' naming scope. For agents not accessible via SNMPv1 or SNMPv2C, the value of this object is the empty string. This object may also contain an empty string if a community string has not yet been assigned by the agent, or no community string with suitable access rights can be returned for a particular SNMP request. Note that this object is deprecated. Agents which implement SNMPv3 access should use the entLogicalContextEngineID and entLogicalContextName objects to identify the context associated with each logical entity. SNMPv3 agents may return a zero-length string for this object, or may continue to return a community string (e.g., tri-lingual agent support).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..20)  

boardSoftwareVersion 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.13
the value indicates the version of software
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..20)  

boardFirmwareVersion 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.14
the value indicates the version of firmware
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..20)  

boardBootVersion 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.15
Boot Version
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..20)  

boardHardwareVersion 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.16
Hardware Version
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..20)  

boardManufactureDate 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.17
Manufacture Date
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..20)  

boardSerialNo 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.18
Manufacture Serial No
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..20)  

boardCpuUsage 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.19
The percentage of CPU usage
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

boardMemoryUsage 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.20
The percentage of used memory
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

boardHasSnmpAgent 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.21
the object indicates whether there is a SNMP agent running on this board.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notpresent(0), snmpv1(1), snmpv2c(2), snmpv3(3)  

boardSnmpAgentIpAddr 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.22
this object indicates and configure IP address of SNMP agent running on this board. now, only GT861's IAD boards surpport this function.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

boardSnmpAgentReadCommunity 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.23
the object indicates and configure the read-only community of SNMP agent running on the board. now, only GT861's IAD boards surpport this function.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

boardSnmpAgentWriteCommunity 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.24
the object indicates and configure the read-write community of SNMP agent running on the board. now, only GT861's IAD boards surpport this function.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

boardTemperatureHighThresholds 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.25
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

boardCpuUsageThresholds 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.26
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

boardMemoryUsageThresholds 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.27
The percentage of used memory
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

boardMemorySize 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.28
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

boardTemperatureLowThresholds 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.29
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

boardAdminStatus 1.3.6.1.4.1.10072.2.20.1.1.2.1.1.30
The desired state of the board.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER up(1), down(2)  

ponPortTable 1.3.6.1.4.1.10072.2.20.1.1.3.1
table of pon port informations
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PonPortEntry

ponPortEntry 1.3.6.1.4.1.10072.2.20.1.1.3.1.1
An entry in the table, containing status and configure information about pon port
Status: current Access: not-accessible
OBJECT-TYPE    
  PonPortEntry  

ponPortIndex 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.1
index of pon port
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2147483647  

ponPortIfIndex 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.2
The value equipped to the index of this pon port in the IF-MIB
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2147483647  

ponPortDot1dBasePort 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.3
port id in the bridge, equipped to the value in the bridge 'dot1dBasePort'
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..65536  

ponPortPartnerDev 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.4
index of the device which contains parter pon port
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ponPortPartnerBrd 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.5
index of board which contains parter pon port
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ponPortPartnerPort 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.6
partnet physical pon port index
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ponPortProtectionDev 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.7
PON Automatic Protection Switching, index of device
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ponPortProtectionBrd 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.8
PON Automatic Protection Switching, index of board
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ponPortProtectionPort 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.9
PON Automatic Protection Switching, index of pon port
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ponPortType 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.10
type of pon port
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER eponMauType1000BasePXOLT(1), eponMauType1000BasePXONU(2), eponMauType1000BasePX10DOLT(3), eponMauType1000BasePX10DONU(4), eponMauType1000BasePX10UOLT(5), eponMauType1000BasePX10UONU(6), eponMauType1000BasePX20DOLT(7), eponMauType1000BasePX20DONU(8), eponMauType1000BasePX20UOLT(9), eponMauType1000BasePX20UONU(10)  

ponPortMaxOnu 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.11
The max number of supported ONUs in this PON port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2147483647  

ponPortCurrOnu 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.12
The current number of registered ONUs in this PON port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..64  

ponPortOperStatus 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.13
operation status of unique pon port
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), unknown(3), loop(4)  

ponPortAlarmStatus 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.14
PON port alarm status, it indicates an alarm with bit=1, if all bit is 0, indicates no alarm.
Status: current Access: read-only
OBJECT-TYPE    
  BITS ber(0), fer(1), abnormal(2), aps(3), link(4), onuLaserAlwaysOn(5), onuOpticalPowerLow(6), onuOpticalPowerHigh(7), ponLOS(8)  

ponPortAlarmMask 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.15
PON Port Alarm mask, the bit=1 indicates mask.
Status: current Access: read-write
OBJECT-TYPE    
  BITS ber(0), fer(1), abnormal(2), aps(3), link(4), onuLaserAlwaysOn(5), onuOpticalPowerLow(6), onuOpticalPowerHigh(7), ponLOS(8)  

ponPortMaxBW 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.16
The max bandwidth supported, unit:KB.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..1000000  

ponPortActBW 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.17
the actual bandwidth, unit:KB.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..2147483647  

ponPortRemainBW 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.18
The current available bandwidth, unit:KB.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..1000000  

ponPortApsCtrl 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.19
PON automatic-protection-switching control.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), auto(2), force(3)  

ponPortApsStatus 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.20
PON automatic-protection-switching status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), active(2), passive(3)  

ponPortEncryptSet 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.21
Encryption set according to every ONU, this value is ignored when the pon port belongs to OLT.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER pure(1), downstreamonly(2), bidirectional(3)  

ponPortOnuLpbCtrl 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.22
ONU Loopback Control, 'noop(1)' is no operation, i.e. the current status is idle; 'lpbStart(2)' is start loopback, only when the object value is 'noop', it can be configurated 'lpbStart(2)', otherwise forbidden, and if success, its value become 'inProcess(4)'; 'lpbStop(3)' is stop loopback, only when the object value is 'inProcess(4)', it can be configurated 'lpbStop(3)', and if success, its value become 'noop(1)'; 'inProcess(4)' is loopbacking status now.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noop(1), lpbStart(2), lpbStop(3), inProcess(4)  

ponPortOnuLpbSource 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.23
Loopback Data Source, 'internal' indicates internal data source, to use testing the link up or down, like ping function; 'external' indicates external data source, to use testing the bandwidth of the ONU ethernet.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER internal(1), external(2)  

ponPortOnuLpbTime 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.24
Loopback Timeout, if the object value is 0, indicate the loopback is processing at all time, if the value is none 0, indicate the loopback time from begin to end, when the time is end it will be auto-stopped. unit:second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

ponPortOnuLpbTxFrms 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.25
The number of frames transmit by this ONU Logical Link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ponPortOnuLpbRxFrms 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.26
The number of frames transmit by this ONU Logical Link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ponEntLogicalIndex 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.27
The value of this object uniquely identifies the logical entity. The value should be a small positive integer; index values for different logical entities are are not necessarily contiguous.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2147483647  

ponEntLogicalCommunity 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.28
An SNMPv1 or SNMPv2C community-string which can be used to access detailed management information for this logical entity. The agent should allow read access with this community string (to an appropriate subset of all managed objects) and may also return a community string based on the privileges of the request used to read this object. Note that an agent may return a community string with read-only privileges, even if this object is accessed with a read- write community string. However, the agent must take care not to return a community string which allows more privileges than the community string used to access this object. A compliant SNMP agent may wish to conserve naming scopes by representing multiple logical entities in a single 'default' naming scope. This is possible when the logical entities represented by the same value of entLogicalCommunity have no object instances in common. For example, 'bridge1' and 'repeater1' may be part of the main naming scope, but at least one additional community string is needed to represent 'bridge2' and 'repeater2'. Logical entities 'bridge1' and 'repeater1' would be represented by sysOREntries associated with the 'default' naming scope. For agents not accessible via SNMPv1 or SNMPv2C, the value of this object is the empty string. This object may also contain an empty string if a community string has not yet been assigned by the agent, or no community string with suitable access rights can be returned for a particular SNMP request. Note that this object is deprecated. Agents which implement SNMPv3 access should use the entLogicalContextEngineID and entLogicalContextName objects to identify the context associated with each logical entity. SNMPv3 agents may return a zero-length string for this object, or may continue to return a community string (e.g., tri-lingual agent support).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..20)  

ponPortLinkedOnuCounter 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.29
The current number of linked ONUs in this PON port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..64  

ponPortAdminStatus 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.30
The desired state of the PON port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER up(1), down(2)  

ponPortReset 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.31
PON interface reset.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noop(1), reset(2)  

ponPortWindowRange 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.32
The max window range of ONU register.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), wr20km(2), wr40km(3), wr60km(4)  

ponPortDownlinkPolicingEbl 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.33
Config onu downlink-policer enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

ponPortAllOnuAlmLevel 1.3.6.1.4.1.10072.2.20.1.1.3.1.1.34
All ONUs alarm-level list.
Status: current Access: read-only
OBJECT-TYPE    
  OnuAlarmLevelList  

ponOnuMapTable 1.3.6.1.4.1.10072.2.20.1.1.3.2
table of pon-ONU map
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PonOnuMapEntry

ponOnuMapEntry 1.3.6.1.4.1.10072.2.20.1.1.3.2.1
An entry in the table
Status: current Access: not-accessible
OBJECT-TYPE    
  PonOnuMapEntry  

mappingOnuIndex 1.3.6.1.4.1.10072.2.20.1.1.3.2.1.1
index of mapping onu
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..64  

onuDevIndex 1.3.6.1.4.1.10072.2.20.1.1.3.2.1.2
device index of this ONU
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2147483647  

onuName 1.3.6.1.4.1.10072.2.20.1.1.3.2.1.3
device name of this ONU
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(255)  

ponPerfMonTable 1.3.6.1.4.1.10072.2.20.1.1.3.3
Table of pon performence
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PonPerfMonEntry

ponPerfMonEntry 1.3.6.1.4.1.10072.2.20.1.1.3.3.1
An entry in the table, containing pon performence monitor information .
Status: current Access: not-accessible
OBJECT-TYPE    
  PonPerfMonEntry  

ponPerfBER 1.3.6.1.4.1.10072.2.20.1.1.3.3.1.1
byte error rate of specified pon port upstream, UNIT: 10E-6
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ponPerfFER 1.3.6.1.4.1.10072.2.20.1.1.3.3.1.4
frame error rate of specified pon port downstream, UNIT: 10E-6
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ponPerfBerAlmEnable 1.3.6.1.4.1.10072.2.20.1.1.3.3.1.5
The value indicates whether enable pon performence BER alarm
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

ponPerfFerAlmEnable 1.3.6.1.4.1.10072.2.20.1.1.3.3.1.6
The value indicates whether enable pon performence FER alarm
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

ponPerfUpBandwidth 1.3.6.1.4.1.10072.2.20.1.1.3.3.1.7
the value indicates upstream bandwidth on this port
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ponPerfDownBandwidth 1.3.6.1.4.1.10072.2.20.1.1.3.3.1.8
the value indicates downstream bandwidth on this port
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ponHisCtrlTable 1.3.6.1.4.1.10072.2.20.1.1.3.4
Table of pon performence
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PonHisCtrlEntry

ponHisCtrlEntry 1.3.6.1.4.1.10072.2.20.1.1.3.4.1
An entry in the table, containing pon performence monitor information .
Status: current Access: not-accessible
OBJECT-TYPE    
  PonHisCtrlEntry  

ponHis15MinuteEnable 1.3.6.1.4.1.10072.2.20.1.1.3.4.1.1
The value indicates whether enable history statistic with interval 15 minutes
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

ponHis24HourEnable 1.3.6.1.4.1.10072.2.20.1.1.3.4.1.2
The value indicates whether enable history statistic with interval 24 hours
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

ponBERThreashold 1.3.6.1.4.1.10072.2.20.1.1.3.5
Ber measurement threshold, the value defination: 0=1e-0=1, 1=1e-1=0.1,......
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..8  

ponFERThreashold 1.3.6.1.4.1.10072.2.20.1.1.3.6
Fer measurement threshold, the value defination: 0=1.00e-0=1, 1=1.00e-1=0.1,......
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..10  

gwEponPonCtcExt 1.3.6.1.4.1.10072.2.20.1.1.3.7
OBJECT IDENTIFIER    

onuAuthEnable 1.3.6.1.4.1.10072.2.20.1.1.4.1
Tok_String
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), auth-new-only(2), auth-all(3)  

onuAuthTable 1.3.6.1.4.1.10072.2.20.1.1.4.2
The table of ONU authentication based MAC address.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OnuAuthEntry

onuAuthEntry 1.3.6.1.4.1.10072.2.20.1.1.4.2.1
An entry in the table
Status: current Access: not-accessible
OBJECT-TYPE    
  OnuAuthEntry  

eponBoardIndex 1.3.6.1.4.1.10072.2.20.1.1.4.2.1.1
The epon board index
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

eponPonPortIndex 1.3.6.1.4.1.10072.2.20.1.1.4.2.1.2
PON port index
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

onuAuthIndex 1.3.6.1.4.1.10072.2.20.1.1.4.2.1.3
MAC address index
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

onuAuthMacAddress 1.3.6.1.4.1.10072.2.20.1.1.4.2.1.4
MAC address
Status: current Access: read-create
OBJECT-TYPE    
  MacAddress  

onuAuthRowStatus 1.3.6.1.4.1.10072.2.20.1.1.4.2.1.5
This object indicates the status of this entry.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

onuToPonBindingEnable 1.3.6.1.4.1.10072.2.20.1.1.4.3
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

onuAuthModeTable 1.3.6.1.4.1.10072.2.20.1.1.4.4
The table of ONU authentication Mode.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OnuAuthModeEntry

onuAuthModeEntry 1.3.6.1.4.1.10072.2.20.1.1.4.4.1
An entry in the table
Status: current Access: not-accessible
OBJECT-TYPE    
  OnuAuthModeEntry  

onuAuthModeBrdIdx 1.3.6.1.4.1.10072.2.20.1.1.4.4.1.1
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

onuAuthModePonIdx 1.3.6.1.4.1.10072.2.20.1.1.4.4.1.2
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

onuAuthMode 1.3.6.1.4.1.10072.2.20.1.1.4.4.1.3
'macAddr(1)' : based ONU MAC address. 'loid(2)' : based ONU logical ID. 'hybrid(3)' : based both macAddr and loid. 'loidNoPwd(4) : based loid, but not check password. 'hybridNoPwd(5)' : based hybrid, but not check password.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER macAddr(1), loid(2), hybrid(3), loidNoPwd(4), hybridNoPwd(5), disable(6)  

onuAuthEnableForPon 1.3.6.1.4.1.10072.2.20.1.1.4.4.1.4
Description
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), auth-new-only(2), auth-all(3)  

onuAuthEntryReorganize 1.3.6.1.4.1.10072.2.20.1.1.4.4.1.5
For PonPort
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER organize(1)  

onuAuthEntryReorganizeForAll 1.3.6.1.4.1.10072.2.20.1.1.4.9
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER organize(1)  

onuAuthLoidTable 1.3.6.1.4.1.10072.2.20.1.1.4.5
The table of ONU authentication based LOID(Logical ONU ID).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OnuAuthLoidEntry

onuAuthLoidEntry 1.3.6.1.4.1.10072.2.20.1.1.4.5.1
An entry in the table
Status: current Access: not-accessible
OBJECT-TYPE    
  OnuAuthLoidEntry  

onuAuthLoidBrdIdx 1.3.6.1.4.1.10072.2.20.1.1.4.5.1.1
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

onuAuthLoidPonIdx 1.3.6.1.4.1.10072.2.20.1.1.4.5.1.2
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

onuAuthLoidIdx 1.3.6.1.4.1.10072.2.20.1.1.4.5.1.3
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..128  

onuAuthLoid 1.3.6.1.4.1.10072.2.20.1.1.4.5.1.4
Tok_String
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(24)  

onuAuthLoidPassword 1.3.6.1.4.1.10072.2.20.1.1.4.5.1.5
Tok_String
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(12)  

onuAuthLoidDevIdx 1.3.6.1.4.1.10072.2.20.1.1.4.5.1.6
Tok_String
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

onuAuthLoidRowStatus 1.3.6.1.4.1.10072.2.20.1.1.4.5.1.7
This object indicates the status of this entry.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

onuUnauthenticatedTable 1.3.6.1.4.1.10072.2.20.1.1.4.6
The table of unauthenticated ONUs based MAC address.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OnuAuth1Entry

onuUnauthenticatedEntry 1.3.6.1.4.1.10072.2.20.1.1.4.6.1
An entry in the table
Status: current Access: not-accessible
OBJECT-TYPE    
  OnuAuth1Entry  

eponUnauthenticatedBoardIndex 1.3.6.1.4.1.10072.2.20.1.1.4.6.1.1
The epon board index
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

eponUnauthenticatedPonPortIndex 1.3.6.1.4.1.10072.2.20.1.1.4.6.1.2
PON port index
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

onuUnauthenticatedIndex 1.3.6.1.4.1.10072.2.20.1.1.4.6.1.3
MAC address index
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

onuUnauthenticatedMacAddress 1.3.6.1.4.1.10072.2.20.1.1.4.6.1.4
MAC address
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

ponLlidTable 1.3.6.1.4.1.10072.2.20.1.1.5.1
Table of the pon llid information
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PonLlidEntry

ponLlidEntry 1.3.6.1.4.1.10072.2.20.1.1.5.1.1
An entry in the table, containing status or configure information
Status: current Access: not-accessible
OBJECT-TYPE    
  PonLlidEntry  

ponLlidIndex 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.1
The pon logic link index
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ponLlidType 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.2
type of pon logic link
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unkown(0), ethlink(1)  

ponLlidOltBoard 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.3
The value equals to entPhysicalIndex in ENTITY-MIB
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ponLlidOltPort 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.4
the pon port id
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ponLlidOltPortIfIndex 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.5
ifIndex of the olt port
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ponLlidOnuPortIfIndex 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.6
ifIndex of the onu port
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ponLlidOnuBoard 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.7
The value indicates board id for this LLID
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ponLlidOnuPort 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.8
The value indicates onu port for this LLID
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ponLlidLLID 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.9
the vlaue of LLID
Status: obsolete Access: read-only
OBJECT-TYPE    
  Integer32 1..2147483647  

ponLlidIfIndex 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.10
The value equals to ''ifIndex'' in IF-MIB according this object'
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2147483647  

ponLlidUpFixedBW 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.11
upstream fixed bandwidth about this pon port, unit:KBps
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..1000000  

ponLlidDownFixedBW 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.12
upstream fixed bandwidth about this pon port, unit:KBps, not support
Status: obsolete Access: read-write
OBJECT-TYPE    
  Integer32 0..1000000  

ponLlidDesc 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.13
description of the LLID
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString  

ponLlidSurportMacNum 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.14
The value of maximum MAC addresses
Status: deprecated Access: read-create
OBJECT-TYPE    
  Integer32 0..8192  

ponLlidOnuMacAddress 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.15
The value indicates and confgure onu MAC address
Status: current Access: read-create
OBJECT-TYPE    
  MacAddress Size(6)  

ponLlidRowStatus 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.16
row status of this entry
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

ponLlidUpBWClass 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.17
upstream class level for this pon port bandwidth allocation
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..7  

ponLlidUpDelay 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.18
upstream delay level for this pon port bandwidth allocation
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER low(1), high(2)  

ponLlidUpAssuredBW 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.19
upstream assured bandwidth about this pon port, unit:KBps
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 64..1000000  

ponLlidUpBesteffortBW 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.20
upstream best-effort bandwidth about this pon port, unit:KBps
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 64..1000000  

ponLlidDownBWClass 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.21
upstream class level for this pon port bandwidth allocation
Status: obsolete Access: read-write
OBJECT-TYPE    
  Integer32 0..7  

ponLlidDownDelay 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.22
upstream delay level for this pon port bandwidth allocation
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER low(1), high(2)  

ponLlidDownAssuredBW 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.23
downstream assured bandwidth about this pon port, unit:KBps
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 64..1000000  

ponLlidDownBesteffortBW 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.24
downstream best-effort bandwidth about this pon port, unit:KBps
Status: obsolete Access: read-write
OBJECT-TYPE    
  Integer32 64..1000000  

ponLlidCtcFecAbility 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.25
FEC ability
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), supported(2), notSupported(3)  

ponLlidCtcFecMode 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.26
FEC mode, unknown(1)-initializing, true state not yet known. enable(2)-activate FEC. disable(3)-deactivate FEC.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), enable(2), disable(3)  

ponLlidCtcEncrypCtrl 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.27
CTC encryption control
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

ponLlidCtcDbaQueSetNum 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.28
DBA queue set number
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..8  

ponLlidCtcDbaQueSetCfgStatus 1.3.6.1.4.1.10072.2.20.1.1.5.1.1.29
The Queue sets configuration status, this object value is always 'noop(1)' when read, 'get(2)' will refresh the object of ponLlidCtcDbaQueSetNum and the table of ponLlidCtcDbaQueSetTable, 'set(3)' will config the data, include ponLlidCtcDbaQueSetNum and ponLlidCtcDbaQueSetTable. 'get(2)' and 'set(3) are only write value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noop(1), get(2), set(3)  

ponLlidCtcDbaQueSetTable 1.3.6.1.4.1.10072.2.20.1.1.5.2
Table of the pon llid DBA information
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PonLlidCtcDbaQueSetEntry

ponLlidCtcDbaQueSetEntry 1.3.6.1.4.1.10072.2.20.1.1.5.2.1
CTC DBA entry
Status: current Access: not-accessible
OBJECT-TYPE    
  PonLlidCtcDbaQueSetEntry  

ponLlidCtcDbaQueSetIndex 1.3.6.1.4.1.10072.2.20.1.1.5.2.1.1
The DBA queue-sets index
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ponLlidCtcDbaReportBitmap 1.3.6.1.4.1.10072.2.20.1.1.5.2.1.2
bit=0 - queue x report is not present, bit=1 - queue x report is present
Status: current Access: read-write
OBJECT-TYPE    
  BITS queue0(0), queue1(1), queue2(2), queue3(3), queue4(4), queue5(5), queue6(6), queue7(7)  

ponLlidCtcDbaQueue0Threshold 1.3.6.1.4.1.10072.2.20.1.1.5.2.1.3
Queue0 threshold
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

ponLlidCtcDbaQueue1Threshold 1.3.6.1.4.1.10072.2.20.1.1.5.2.1.4
Queue1 threshold
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

ponLlidCtcDbaQueue2Threshold 1.3.6.1.4.1.10072.2.20.1.1.5.2.1.5
Queue2 threshold
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

ponLlidCtcDbaQueue3Threshold 1.3.6.1.4.1.10072.2.20.1.1.5.2.1.6
Queue3 threshold
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

ponLlidCtcDbaQueue4Threshold 1.3.6.1.4.1.10072.2.20.1.1.5.2.1.7
Queue4 threshold
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

ponLlidCtcDbaQueue5Threshold 1.3.6.1.4.1.10072.2.20.1.1.5.2.1.8
Queue5 threshold
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

ponLlidCtcDbaQueue6Threshold 1.3.6.1.4.1.10072.2.20.1.1.5.2.1.9
Queue6 threshold
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

ponLlidCtcDbaQueue7Threshold 1.3.6.1.4.1.10072.2.20.1.1.5.2.1.10
Queue7 threshold
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

onuNewRegSuccess 1.3.6.1.4.1.10072.2.20.1.1.6.1
A new ONU register success.
Status: current Access: read-write
NOTIFICATION-TYPE    

onuReregSuccess 1.3.6.1.4.1.10072.2.20.1.1.6.2
An ONU reregister success.
Status: current Access: read-write
NOTIFICATION-TYPE    

onuNotPresent 1.3.6.1.4.1.10072.2.20.1.1.6.3
An ONU is not present alarm
Status: current Access: read-write
NOTIFICATION-TYPE    

devPowerOff 1.3.6.1.4.1.10072.2.20.1.1.6.4
device Power Off Alarm
Status: current Access: read-write
NOTIFICATION-TYPE    

devPowerOn 1.3.6.1.4.1.10072.2.20.1.1.6.5
device Power On Alarm
Status: current Access: read-write
NOTIFICATION-TYPE    

cfgDataSaveSuccess 1.3.6.1.4.1.10072.2.20.1.1.6.6
saving config data to flash successfully
Status: current Access: read-write
NOTIFICATION-TYPE    

cfgDataSaveFail 1.3.6.1.4.1.10072.2.20.1.1.6.7
saving config data to flash unsuccessfully
Status: current Access: read-write
NOTIFICATION-TYPE    

flashClearSuccess 1.3.6.1.4.1.10072.2.20.1.1.6.8
clear config data successfully
Status: current Access: read-write
NOTIFICATION-TYPE    

flashClearFail 1.3.6.1.4.1.10072.2.20.1.1.6.9
clear config data unsuccessfully
Status: current Access: read-write
NOTIFICATION-TYPE    

softwareUpdateSuccess 1.3.6.1.4.1.10072.2.20.1.1.6.10
update software successfully
Status: current Access: read-write
NOTIFICATION-TYPE    

softwareUpdateFail 1.3.6.1.4.1.10072.2.20.1.1.6.11
update software unsuccessfully
Status: current Access: read-write
NOTIFICATION-TYPE    

firmwareUpdateSuccess 1.3.6.1.4.1.10072.2.20.1.1.6.12
firmware update successfully
Status: current Access: read-write
NOTIFICATION-TYPE    

firmwareUpdateFail 1.3.6.1.4.1.10072.2.20.1.1.6.13
update firmware unsuccessfully
Status: current Access: read-write
NOTIFICATION-TYPE    

cfgDataBackupSuccess 1.3.6.1.4.1.10072.2.20.1.1.6.14
backup configuration data to NMS successfully.
Status: current Access: read-write
NOTIFICATION-TYPE    

cfgDataBackupFail 1.3.6.1.4.1.10072.2.20.1.1.6.15
backup configuration data to NMS unsuccessfully.
Status: current Access: read-write
NOTIFICATION-TYPE    

cfgDataRestoreSuccess 1.3.6.1.4.1.10072.2.20.1.1.6.16
restore configuration data from NMS successfully.
Status: current Access: read-write
NOTIFICATION-TYPE    

cfgDataRestoreFail 1.3.6.1.4.1.10072.2.20.1.1.6.17
restore configuration data from NMS unsuccessfully.
Status: current Access: read-write
NOTIFICATION-TYPE    

autoProtectSwitch 1.3.6.1.4.1.10072.2.20.1.1.6.18
Auto Protect Switch(APS) occurs
Status: current Access: read-write
NOTIFICATION-TYPE    

cpuUsageFactorHigh 1.3.6.1.4.1.10072.2.20.1.1.6.19
high cpu usage factor alarm
Status: current Access: read-write
NOTIFICATION-TYPE    

ponPortBERAlarm 1.3.6.1.4.1.10072.2.20.1.1.6.20
pon port BER alarm
Status: current Access: read-write
NOTIFICATION-TYPE    

ponPortBERAlarmClear 1.3.6.1.4.1.10072.2.20.1.1.6.21
pon port BER alarm clear
Status: current Access: read-write
NOTIFICATION-TYPE    

ponPortFERAlarm 1.3.6.1.4.1.10072.2.20.1.1.6.22
pon port FER alarm
Status: current Access: read-write
NOTIFICATION-TYPE    

ponPortFERAlarmClear 1.3.6.1.4.1.10072.2.20.1.1.6.23
pon port FER alarm clear
Status: current Access: read-write
NOTIFICATION-TYPE    

llidActBWExceeding 1.3.6.1.4.1.10072.2.20.1.1.6.24
llid bandwidth exceed the limit
Status: current Access: read-write
NOTIFICATION-TYPE    

llidActBWExceedingClear 1.3.6.1.4.1.10072.2.20.1.1.6.25
llid bandwidth return to appropriate value
Status: current Access: read-write
NOTIFICATION-TYPE    

devBoardInterted 1.3.6.1.4.1.10072.2.20.1.1.6.26
insert a board
Status: current Access: read-write
NOTIFICATION-TYPE    

devBoardPull 1.3.6.1.4.1.10072.2.20.1.1.6.27
pull a board out
Status: current Access: read-write
NOTIFICATION-TYPE    

powerOffAlarm 1.3.6.1.4.1.10072.2.20.1.1.6.30
power OFF alarm
Status: current Access: read-write
NOTIFICATION-TYPE    

powerOnAlarm 1.3.6.1.4.1.10072.2.20.1.1.6.31
power ON alarm
Status: current Access: read-write
NOTIFICATION-TYPE    

boardTemperatureHigh 1.3.6.1.4.1.10072.2.20.1.1.6.32
board temperature high alarm
Status: current Access: read-write
NOTIFICATION-TYPE    

boardTemperatureHighClear 1.3.6.1.4.1.10072.2.20.1.1.6.33
board temperature high alarm clear
Status: current Access: read-write
NOTIFICATION-TYPE    

ponBoardReset 1.3.6.1.4.1.10072.2.20.1.1.6.34
PON board reset event occur
Status: current Access: read-write
NOTIFICATION-TYPE    

swBoardProtectedSwitch 1.3.6.1.4.1.10072.2.20.1.1.6.35
sw board protected switch event occur
Status: current Access: read-write
NOTIFICATION-TYPE    

ponPortAbnormal 1.3.6.1.4.1.10072.2.20.1.1.6.36
abnormal status on PON port occur
Status: current Access: read-write
NOTIFICATION-TYPE    

onuRegisterConflict 1.3.6.1.4.1.10072.2.20.1.1.6.37
onu register conflict
Status: current Access: read-write
NOTIFICATION-TYPE    

firmwareLoadSuccess 1.3.6.1.4.1.10072.2.20.1.1.6.38
firmware load successfully
Status: current Access: read-write
NOTIFICATION-TYPE    

firmwareLoadFailure 1.3.6.1.4.1.10072.2.20.1.1.6.39
firmware load fail
Status: current Access: read-write
NOTIFICATION-TYPE    

dbaUpdateSuccess 1.3.6.1.4.1.10072.2.20.1.1.6.40
update dba successfully
Status: current Access: read-write
NOTIFICATION-TYPE    

dbaUpdateFailure 1.3.6.1.4.1.10072.2.20.1.1.6.41
update dba faul
Status: current Access: read-write
NOTIFICATION-TYPE    

dbaLoadSuccess 1.3.6.1.4.1.10072.2.20.1.1.6.42
load dba successfully
Status: current Access: read-write
NOTIFICATION-TYPE    

dbaLoadFailure 1.3.6.1.4.1.10072.2.20.1.1.6.43
load dba fail
Status: current Access: read-write
NOTIFICATION-TYPE    

ponToEthLinkdown 1.3.6.1.4.1.10072.2.20.1.1.6.44
.
Status: current Access: read-write
NOTIFICATION-TYPE    

ponToEthLinkup 1.3.6.1.4.1.10072.2.20.1.1.6.45
.
Status: current Access: read-write
NOTIFICATION-TYPE    

onuSoftwareLoadSuccess 1.3.6.1.4.1.10072.2.20.1.1.6.46
load onu software successfully
Status: current Access: read-write
NOTIFICATION-TYPE    

onuSoftwareLoadFailure 1.3.6.1.4.1.10072.2.20.1.1.6.47
load onu software fail
Status: current Access: read-write
NOTIFICATION-TYPE    

ethLinkdown 1.3.6.1.4.1.10072.2.20.1.1.6.54
Ethernet port linkdown alarm.
Status: current Access: read-write
NOTIFICATION-TYPE    

ethLinkup 1.3.6.1.4.1.10072.2.20.1.1.6.55
Ethernet port linkup alarm.
Status: current Access: read-write
NOTIFICATION-TYPE    

bootUpdateSuccess 1.3.6.1.4.1.10072.2.20.1.1.6.56
boot firmware update successfully notification
Status: current Access: read-write
NOTIFICATION-TYPE    

bootUpdateFailure 1.3.6.1.4.1.10072.2.20.1.1.6.57
boot firmware update fail notification
Status: current Access: read-write
NOTIFICATION-TYPE    

batFileBackupSuccess 1.3.6.1.4.1.10072.2.20.1.1.6.58
bat file backup successfully notification
Status: current Access: read-write
NOTIFICATION-TYPE    

batFileBackupFailure 1.3.6.1.4.1.10072.2.20.1.1.6.59
bat file backup fail notification
Status: current Access: read-write
NOTIFICATION-TYPE    

batFileRestoreSuccess 1.3.6.1.4.1.10072.2.20.1.1.6.60
bat file restore successfully notification
Status: current Access: read-write
NOTIFICATION-TYPE    

batFileRestoreFailure 1.3.6.1.4.1.10072.2.20.1.1.6.61
bat file restore fail notification
Status: current Access: read-write
NOTIFICATION-TYPE    

onuRegAuthFailure 1.3.6.1.4.1.10072.2.20.1.1.6.62
Illegal ONU register.
Status: current Access: read-write
NOTIFICATION-TYPE    

deviceColdStart 1.3.6.1.4.1.10072.2.20.1.1.6.63
Only report OLT cold start. this trap is not sent if a devPowerOn trap is sent for the same restart. Implementation of this trap is optional.
Status: current Access: read-write
NOTIFICATION-TYPE    

deviceWarmStart 1.3.6.1.4.1.10072.2.20.1.1.6.64
Only report OLT warm start.
Status: current Access: read-write
NOTIFICATION-TYPE    

deviceExceptionRestart 1.3.6.1.4.1.10072.2.20.1.1.6.65
Only report OLT restart because of exception.
Status: current Access: read-write
NOTIFICATION-TYPE    

ethLoopAlarm 1.3.6.1.4.1.10072.2.20.1.1.6.84
Ethernet port loop alarm.
Status: current Access: read-write
NOTIFICATION-TYPE    

ethLoopAlarmClear 1.3.6.1.4.1.10072.2.20.1.1.6.85
Ethernet port loop clear.
Status: current Access: read-write
NOTIFICATION-TYPE    

onuLoopAlarm 1.3.6.1.4.1.10072.2.20.1.1.6.86
Onu loop alarm.
Status: current Access: read-write
NOTIFICATION-TYPE    

onuLoopAlarmClear 1.3.6.1.4.1.10072.2.20.1.1.6.87
Onu loop clear.
Status: current Access: read-write
NOTIFICATION-TYPE    

backboneEthLinkdown 1.3.6.1.4.1.10072.2.20.1.1.6.88
Ethernet port linkdown alarm.
Status: current Access: read-write
NOTIFICATION-TYPE    

backboneEthLinkup 1.3.6.1.4.1.10072.2.20.1.1.6.89
Ethernet port linkup alarm.
Status: current Access: read-write
NOTIFICATION-TYPE    

boardCpuUsageAlarm 1.3.6.1.4.1.10072.2.20.1.1.6.116
cpu usage factor alarm
Status: current Access: read-write
NOTIFICATION-TYPE    

boardCpuUsageAlarmClear 1.3.6.1.4.1.10072.2.20.1.1.6.117
cpu usage factor alarm clear
Status: current Access: read-write
NOTIFICATION-TYPE    

boardMemoryUsageAlarm 1.3.6.1.4.1.10072.2.20.1.1.6.118
Tok_String
Status: current Access: read-write
NOTIFICATION-TYPE    

boardMemoryUsageAlarmClear 1.3.6.1.4.1.10072.2.20.1.1.6.119
Tok_String
Status: current Access: read-write
NOTIFICATION-TYPE    

ponPortFullAlarm 1.3.6.1.4.1.10072.2.20.1.1.6.132
Tok_String
Status: current Access: read-write
NOTIFICATION-TYPE    

ponPortAbnormalClear 1.3.6.1.4.1.10072.2.20.1.1.6.133
Tok_String
Status: current Access: read-write
NOTIFICATION-TYPE    

ethPortBroadCastFloodControl 1.3.6.1.4.1.10072.2.20.1.1.6.136
Ethernet port broadcast flood alarm.
Status: current Access: read-write
NOTIFICATION-TYPE    

ethPortBroadCastFloodControlClear 1.3.6.1.4.1.10072.2.20.1.1.6.137
Ethernet port broadcast flood alarm clear.
Status: current Access: read-write
NOTIFICATION-TYPE    

sysfileUploadsuccess 1.3.6.1.4.1.10072.2.20.1.1.6.138
Tok_String
Status: current Access: read-write
NOTIFICATION-TYPE    

sysfileUploadfailure 1.3.6.1.4.1.10072.2.20.1.1.6.139
Tok_String
Status: current Access: read-write
NOTIFICATION-TYPE    

sysfileDownloadsuccess 1.3.6.1.4.1.10072.2.20.1.1.6.140
Tok_String
Status: current Access: read-write
NOTIFICATION-TYPE    

sysfileDownloadfailure 1.3.6.1.4.1.10072.2.20.1.1.6.141
Tok_String
Status: current Access: read-write
NOTIFICATION-TYPE    

ponPortLosAlarm 1.3.6.1.4.1.10072.2.20.1.1.6.142
Tok_String
Status: current Access: read-write
NOTIFICATION-TYPE    

ponPortLosAlarmClear 1.3.6.1.4.1.10072.2.20.1.1.6.143
Tok_String
Status: current Access: read-write
NOTIFICATION-TYPE    

ponFWVersionMismatch 1.3.6.1.4.1.10072.2.20.1.1.6.144
Tok_String
Status: current Access: read-write
NOTIFICATION-TYPE    

ponFWVersionMatch 1.3.6.1.4.1.10072.2.20.1.1.6.145
Tok_String
Status: current Access: read-write
NOTIFICATION-TYPE    

ponDBAVersionMismatch 1.3.6.1.4.1.10072.2.20.1.1.6.146
Tok_String
Status: current Access: read-write
NOTIFICATION-TYPE    

ponDBAVersionMatch 1.3.6.1.4.1.10072.2.20.1.1.6.147
Tok_String
Status: current Access: read-write
NOTIFICATION-TYPE    

ponSFPTypeMismatch 1.3.6.1.4.1.10072.2.20.1.1.6.148
Tok_String
Status: current Access: read-write
NOTIFICATION-TYPE    

ponSFPTypeMitch 1.3.6.1.4.1.10072.2.20.1.1.6.149
Tok_String
Status: current Access: read-write
NOTIFICATION-TYPE    

ponPortBRASAlarm 1.3.6.1.4.1.10072.2.20.1.1.6.150
Tok_String
Status: current Access: read-write
NOTIFICATION-TYPE    

ponPortBRASAlarmClear 1.3.6.1.4.1.10072.2.20.1.1.6.151
Tok_String
Status: current Access: read-write
NOTIFICATION-TYPE    

ponPortUpNoTraffic 1.3.6.1.4.1.10072.2.20.1.1.6.152
Tok_String
Status: current Access: read-write
NOTIFICATION-TYPE    

ponPortUpNoTrafficClear 1.3.6.1.4.1.10072.2.20.1.1.6.153
Tok_String
Status: current Access: read-write
NOTIFICATION-TYPE    

onuDeletingNotify 1.3.6.1.4.1.10072.2.20.1.1.6.154
Illegal ONU register.
Status: current Access: read-write
NOTIFICATION-TYPE    

onuMacTableOverFlow 1.3.6.1.4.1.10072.2.20.1.1.6.208
onu mac table over flow.
Status: current Access: read-write
NOTIFICATION-TYPE    

onuMacTableOverFlowClear 1.3.6.1.4.1.10072.2.20.1.1.6.209
onu mac table over flow clear.
Status: current Access: read-write
NOTIFICATION-TYPE    

onuNotPresentAlmLevel 1.3.6.1.4.1.10072.2.20.1.1.7.1
the value indicates an alarm level is set on this event
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4  

devPowerOffAlmLevel 1.3.6.1.4.1.10072.2.20.1.1.7.2
the value indicates an alarm level is set on this event
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4  

ponPortBERAlarmLevel 1.3.6.1.4.1.10072.2.20.1.1.7.3
the value indicates an alarm level is set on this event
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4  

ponPortFERAlarmLevel 1.3.6.1.4.1.10072.2.20.1.1.7.4
the value indicates an alarm level is set on this event
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4  

llidActBWExceedingAlarmLevel 1.3.6.1.4.1.10072.2.20.1.1.7.5
the value indicates an alarm level is set on this event
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4  

powerOffAlarmLevel 1.3.6.1.4.1.10072.2.20.1.1.7.6
the value indicates an alarm level is set on this event
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4  

boardTemperatureHighAlarmLevel 1.3.6.1.4.1.10072.2.20.1.1.7.7
the value indicates an alarm level is set on this event
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4  

devBoardPullAlarmLevel 1.3.6.1.4.1.10072.2.20.1.1.7.8
the value indicates an alarm level is set on this event
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4  

ethLinkdownAlarmLevel 1.3.6.1.4.1.10072.2.20.1.1.7.9
the value indicates an alarm level is set on this event
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4  

devFanAlarmAlarmLevel 1.3.6.1.4.1.10072.2.20.1.1.7.10
the value indicates an alarm level is set on this event
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4  

ethFlrAlarmLevel 1.3.6.1.4.1.10072.2.20.1.1.7.11
the value indicates an alarm level is set on this event
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4  

ethFerAlarmLevel 1.3.6.1.4.1.10072.2.20.1.1.7.12
the value indicates an alarm level is set on this event
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4  

ethTransmittalIntermitAlarmLevel 1.3.6.1.4.1.10072.2.20.1.1.7.13
the value indicates an alarm level is set on this event
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4  

gwEponPonCtcExtOamDiscoveryTiming 1.3.6.1.4.1.10072.2.20.1.1.3.7.1
extended oam discovery timing, unit: ms
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2550  

gwEponPonCtcExtOamCtcOui 1.3.6.1.4.1.10072.2.20.1.1.3.7.2
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(16)  

gwEponPonCtcExtOamCtcVer 1.3.6.1.4.1.10072.2.20.1.1.3.7.3
CTC ext-oam version
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..255  

gwEponPonCtcEncrypUpdKeyTime 1.3.6.1.4.1.10072.2.20.1.1.3.7.4
Update key time, unit: s
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

gwEponPonCtcEncrypNoReplyTimeout 1.3.6.1.4.1.10072.2.20.1.1.3.7.5
No reply timeout, unit: ms
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2550  

gwEponPonCtcEncrypTimingThreshold 1.3.6.1.4.1.10072.2.20.1.1.3.7.6
Encryption timing threshold
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

gwConsoleBaudRate 1.3.6.1.4.1.10072.2.20.1.1.8.1
the baud rate for the system console
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER b300(1), b600(2), b1200(3), b2400(4), b4800(5), b9600(6), b19200(7), b38400(8), b115200(9), b230400(10)  

gwConsoleDataBits 1.3.6.1.4.1.10072.2.20.1.1.8.2
the data bits length for the system console
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER b5(5), b6(6), b7(7), b8(8)  

gwConsoleStopBitSet 1.3.6.1.4.1.10072.2.20.1.1.8.3
the stop bits for the system console
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sb1(1), sb2(2)  

gwConsoleParitySet 1.3.6.1.4.1.10072.2.20.1.1.8.4
the parity set for the system console
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), even(2), odd(3), space(4)  

gwConsoleFlowCtrlSet 1.3.6.1.4.1.10072.2.20.1.1.8.5
the flow control set for the system console
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)