GDC-SC800T3-MIB
File:
GDC-SC800T3-MIB.mib (88791 bytes)
Imported modules
Imported symbols
Defined Types
Sc800t3VersionEntry |
|
SEQUENCE |
|
|
|
|
sc800t3VersionIndex |
SCinstance |
|
|
sc800t3ActiveFirmwareRev |
DisplayString |
|
|
sc800t3StandbyFirmwareRev |
DisplayString |
|
|
sc800t3StoredFirmwareStatus |
INTEGER |
|
|
sc800t3SwitchActiveFirmware |
INTEGER |
|
|
sc800t3DownloadingMode |
INTEGER |
|
|
sc800t3EraseFlash |
INTEGER |
|
Sc800t3ChannelConfigEntry |
|
SEQUENCE |
|
|
|
|
sc800t3ChannelConfigIndex |
SCinstance |
|
|
sc800t3ForcedDCE |
INTEGER |
|
|
sc800t3ChannelDTEtest |
INTEGER |
|
|
sc800t3DTELoopTimeout |
INTEGER |
|
Sc800t3NetworkConfigEntry |
|
SEQUENCE |
|
|
|
|
sc800t3NetworkConfigIndex |
SCinstance |
|
|
sc800t3NetworkFrameType |
INTEGER |
|
|
sc800t3NetworkTransmitClockSource |
INTEGER |
|
|
sc800t3NetworkAISLoopdown |
INTEGER |
|
|
sc800t3NetworkLineType |
INTEGER |
|
|
sc800t3NetworkIdleStatus |
INTEGER |
|
|
sc800t3NetworkTransmitIdleStatus |
INTEGER |
|
|
sc800t3NetworkSesBERThreshold |
INTEGER |
|
|
sc800t3InbandLoopback |
INTEGER |
|
Sc800t3DiagEntry |
|
SEQUENCE |
|
|
|
|
sc800t3DiagIndex |
SCinstance |
|
|
sc800t3DiagTestDuration |
INTEGER |
|
|
sc800t3InsertBitError |
INTEGER |
|
|
sc800t3DiagT3Test |
INTEGER |
|
|
sc800t3DiagTestResults |
OCTET STRING |
|
|
sc800t3DiagResetTestResults |
INTEGER |
|
Sc800t3MaintenanceEntry |
|
SEQUENCE |
|
|
|
|
sc800t3MaintenanceIndex |
SCinstance |
|
|
sc800t3LedStatus |
OCTET STRING |
|
|
sc800t3SoftReset |
INTEGER |
|
|
sc800t3DefaultInit |
INTEGER |
|
|
sc800t3ValidNearEndIntervals |
INTEGER |
|
|
sc800t3ValidFarEndIntervals |
INTEGER |
|
|
sc800t3ShelfType |
INTEGER |
|
|
sc800t3TwinPackPowerSupply |
INTEGER |
|
|
sc800t3TestAllLeds |
INTEGER |
|
|
sc800t3NearEndResetStats |
INTEGER |
|
|
sc800t3FarEndResetStats |
INTEGER |
|
|
sc800t3NearEndStatLastInitial |
INTEGER |
|
|
sc800t3FarEndStatLastInitial |
INTEGER |
|
Sc800t3AlarmConfigEntry |
|
SEQUENCE |
|
|
|
|
sc800t3AlarmConfigIndex |
SCinstance |
|
|
sc800t3AlarmConfigIdentifier |
OBJECT IDENTIFIER |
|
|
sc800t3AlarmCountWindow |
INTEGER |
|
|
sc800t3AlarmCountThreshold |
INTEGER |
|
Sc800t3CurrentNearEndEntry |
|
SEQUENCE |
|
|
|
|
sc800t3CurrentNearEndIndex |
SCinstance |
|
|
sc800t3CurrentNearEndStat |
OCTET STRING |
|
Sc800t3CurrentFarEndEntry |
|
SEQUENCE |
|
|
|
|
sc800t3CurrentFarEndIndex |
SCinstance |
|
|
sc800t3CurrentFarEndStat |
OCTET STRING |
|
Sc800t3CurrentDayNearEndEntry |
|
SEQUENCE |
|
|
|
|
sc800t3CurrentDayNearEndIndex |
SCinstance |
|
|
sc800t3CurrentDayNearEndStat |
OCTET STRING |
|
Sc800t3CurrentDayFarEndEntry |
|
SEQUENCE |
|
|
|
|
sc800t3CurrentDayFarEndIndex |
SCinstance |
|
|
sc800t3CurrentDayFarEndStat |
OCTET STRING |
|
Sc800t3PreviousDayNearEndEntry |
|
SEQUENCE |
|
|
|
|
sc800t3PreviousDayNearEndIndex |
SCinstance |
|
|
sc800t3PreviousDayNearEndStat |
OCTET STRING |
|
Sc800t3PreviousDayFarEndEntry |
|
SEQUENCE |
|
|
|
|
sc800t3PreviousDayFarEndIndex |
SCinstance |
|
|
sc800t3PreviousDayFarEndStat |
OCTET STRING |
|
Sc800t3NearEndIntervalEntry |
|
SEQUENCE |
|
|
|
|
sc800t3NearEndIntervalIndex |
SCinstance |
|
|
sc800t3NearEndIntervalNumber |
INTEGER |
|
|
sc800t3NearEndIntervalStats |
OCTET STRING |
|
Sc800t3FarEndIntervalEntry |
|
SEQUENCE |
|
|
|
|
sc800t3FarEndIntervalIndex |
SCinstance |
|
|
sc800t3FarEndIntervalNumber |
INTEGER |
|
|
sc800t3FarEndIntervalStats |
OCTET STRING |
|
Sc800t3PreviousNearEndEntry |
|
SEQUENCE |
|
|
|
|
sc800t3PreviousNearEndIndex |
SCinstance |
|
|
sc800t3PreviousNearEndStat |
OCTET STRING |
|
Sc800t3PreviousFarEndEntry |
|
SEQUENCE |
|
|
|
|
sc800t3PreviousFarEndIndex |
SCinstance |
|
|
sc800t3PreviousFarEndStat |
OCTET STRING |
|
Sc800t3LocalAlarmConfigEntry |
|
SEQUENCE |
|
|
|
|
sc800t3LocalAlarmConfigIndex |
SCinstance |
|
|
sc800t3OOF |
INTEGER |
|
|
sc800t3AISLOCAL |
INTEGER |
|
|
sc800t3TIMLOS |
INTEGER |
|
|
sc800t3TXDLOS |
INTEGER |
|
|
sc800t3RXDLOS |
INTEGER |
|
|
sc800t3LOS |
INTEGER |
|
|
sc800t3TPSFAIL |
INTEGER |
|
|
sc800t3BPSFAIL |
INTEGER |
|
|
sc800t3DTECLKLOS |
INTEGER |
|
|
sc800t3DTERDYLOS |
INTEGER |
|
|
sc800t3RAILOCAL |
INTEGER |
|
|
sc800t3THRESHESL |
INTEGER |
|
|
sc800t3THRESHES |
INTEGER |
|
|
sc800t3THRESHSES |
INTEGER |
|
|
sc800t3THRESHSAS |
INTEGER |
|
|
sc800t3THRESHUAS |
INTEGER |
|
|
sc800t3THRESHCV |
INTEGER |
|
Defined Values
ds3 |
1.3.6.1.4.1.498.19 |
OBJECT IDENTIFIER |
|
|
|
sc800t3 |
1.3.6.1.4.1.498.19.1 |
OBJECT IDENTIFIER |
|
|
|
sc800t3Maintenance |
1.3.6.1.4.1.498.19.1.4 |
OBJECT IDENTIFIER |
|
|
|
sc800t3MIBversion |
1.3.6.1.4.1.498.19.1.1.1 |
Identifies the version of the MIB. The format of the version
is x.yzT, where 'x' identifies the major revision number, 'y'
identifies the minor revision number, 'z' identifies the
typographical revision, and T identifies the test revision.
Upon formal release, no designation for the test revision will
be present. Acceptable values for the individual revision
components are as follows:
x: 1 - 9, y: 0 - 9, z: 0 - 9, T: A - Z |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(5) |
|
sc800t3VersionEntry |
1.3.6.1.4.1.498.19.1.1.2.1 |
An entry in the GDC SC800T3 Version Table. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Sc800t3VersionEntry |
|
|
sc800t3VersionIndex |
1.3.6.1.4.1.498.19.1.1.2.1.1 |
Integer value which uniquely identifies the SC800T3 to which this
entry is applicable. SCinstance is defined to be SLDi where:
S (byte value) - physical shelf slot location (01-32)
L (byte value) - line number (01)
D (byte value) - drop number (00)
i (byte value) - interface number (00) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SCinstance |
|
|
sc800t3ActiveFirmwareRev |
1.3.6.1.4.1.498.19.1.1.2.1.2 |
The version number of the firmware currently executing.
The format is MM.NN.BB where:
MM: Major Revision (0-99)
NN: Minor Revision (0-99)
BB: Bug Fix Revision (0-99) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(8) |
|
sc800t3StandbyFirmwareRev |
1.3.6.1.4.1.498.19.1.1.2.1.3 |
The version number of the firmware stored (in a compressed format)
but not currently executing.
MM: Major Revision (0-99)
NN: Minor Revision (0-99)
BB: Bug Fix Revision (0-99)
|
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(8) |
|
sc800t3StoredFirmwareStatus |
1.3.6.1.4.1.498.19.1.1.2.1.4 |
This object represents the state of the Non-Active or Stored firmware:
statBlank(1) Factory Default
statDownLoading(2) In process of downloading firmware
statOK(3) Zipped version checksum succesful (OK to switch)
(can set sc800t3SwitchActive to switchActive(2))
statCheckSumBad(4) Failed checksum after download
statUnZipping(5) In process of uncompressing into active area
statBadUnZip(6) Failed last uncompress
statDownloadAborted(7) Download aborted by user |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
statBlank(1), statDownLoading(2), statOK(3), statCheckSumBad(4), statUnZipping(5), statBadUnZip(6), statDownloadAborted(7) |
|
sc800t3SwitchActiveFirmware |
1.3.6.1.4.1.498.19.1.1.2.1.5 |
This object is used to switch the active executing firmware from the version
in sc800t3ActiveRev to the version in sc800t3StoredRev.
When a switchActive(2) is set (write only) the element will:
1) reboot
2) uncompress stored code into active area
3) perform checksum on active area
4) Set sc800t3StoredStatus object to indicate results
5) If succesfull:
update sc800t3ActiveFirmwareRev and sc800t3StoredFirmwareRev
and begin executing
If failed:
replace active area with previous revision
The switchNorm(1) enumeration will always be read.
Setting switchActive(2) when the sc800t3StoredStatus is not statOK(3) will
result in an error.
|
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
switchNorm(1), switchActive(2) |
|
sc800t3DownloadingMode |
1.3.6.1.4.1.498.19.1.1.2.1.6 |
This object is used to configure the download mode:
disableAll(1) Prevents any firmware downloading to SC800T3
enableAndWait(2) Allows downloading zipped code to be stored
only!
enableAndSwitch(3) Allows downloading and then unzips and begins
executing the new code |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disableAll(1), enableAndWait(2), enableAndSwitch(3) |
|
sc800t3EraseFlash |
1.3.6.1.4.1.498.19.1.1.2.1.7 |
A set of this object to erase(2) will erase the application
stored in flash. After setting this object, there should
be a delay of at least 2 minutes before downloading the
unit. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normal(1), erase(2) |
|
sc800t3ChannelConfigEntry |
1.3.6.1.4.1.498.19.1.2.1.1 |
The sc800t3 Channel Configuration table entry. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Sc800t3ChannelConfigEntry |
|
|
sc800t3ChannelConfigIndex |
1.3.6.1.4.1.498.19.1.2.1.1.1 |
Integer value which uniquely identifies the SC800T3 to which this
entry is applicable. SCinstance is defined to be SLDi where:
S (byte value) - physical shelf slot location (01-32)
L (byte value) - line number (01)
D (byte value) - drop number (00)
i (byte value) - interface number (00) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SCinstance |
|
|
sc800t3ForcedDCE |
1.3.6.1.4.1.498.19.1.2.1.1.2 |
Controls the operation of Data Communications Equipment (DCE) signal.
The value followsDte(1) indicates that the channel's DCE follows
Data Terminal Equipment (DTE) ready. The value forcedOn(2) indicates
that DCE is forced on. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
followsDte(1), forcedOn(2) |
|
sc800t3ChannelDTEtest |
1.3.6.1.4.1.498.19.1.2.1.1.3 |
DTE interface supporting loop A and loop B tests. See ANSI TIA/EIA-613-1993
specification for details on encoding of inter changes. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabled(2) |
|
sc800t3DTELoopTimeout |
1.3.6.1.4.1.498.19.1.2.1.1.4 |
Enables/disables DTE loop time out. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabled(2) |
|
sc800t3NetworkConfigEntry |
1.3.6.1.4.1.498.19.1.2.2.1 |
The sc800t3 Network Configuration table entry. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Sc800t3NetworkConfigEntry |
|
|
sc800t3NetworkConfigIndex |
1.3.6.1.4.1.498.19.1.2.2.1.1 |
Integer value which uniquely identifies the SC800T3 to which this
entry is applicable. SCinstance is defined to be SLDi where:
S (byte value) - physical shelf slot location (01-32)
L (byte value) - line number (01)
D (byte value) - drop number (00)
i (byte value) - interface number (00) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SCinstance |
|
|
sc800t3NetworkFrameType |
1.3.6.1.4.1.498.19.1.2.2.1.2 |
Is the framing type of the network interface. Setting the
value of the object to m13(1) configures the network interface
to M-13 framing. Setting the value of this object to
cbitParity configures the network interface 20 C-bit parity
framing |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
m13(1), cbitParity(2) |
|
sc800t3NetworkTransmitClockSource |
1.3.6.1.4.1.498.19.1.2.2.1.3 |
The DSU transmit clock source option.
This is the selection for the transmitter
timing clock source. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
internal(1), receive(2) |
|
sc800t3NetworkAISLoopdown |
1.3.6.1.4.1.498.19.1.2.2.1.4 |
The time in seconds when receiving a continuous AIS signal
before a remotely initiated loopback is terminated. When this
object has the value 4, then there is no time limit and the
loop must be terminated by remotely issued in-band loopdown
codes. When the object has a value between 5 and 60, then
this is time in seconds of continuous AIS signal before
the loopback is terminated. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
4..60 |
|
sc800t3NetworkLineType |
1.3.6.1.4.1.498.19.1.2.2.1.5 |
The operating mode of the interface. Setting the value of
this object to longCable(1) configures the interface as
standard DS-3. Setting the value of this object to
shortCable(2) configures the interface to operate as a standard
cross-connect DSX-3. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
longCable(1), shortCable(2) |
|
sc800t3NetworkIdleStatus |
1.3.6.1.4.1.498.19.1.2.2.1.6 |
Returns a value of received(2) when the sc800t3 receives
a DS3 idle from the network. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notReceived(1), received(2) |
|
sc800t3NetworkTransmitIdleStatus |
1.3.6.1.4.1.498.19.1.2.2.1.7 |
When set to active(2), the sc800t3 will transmit a DS3 idle
signal to the network. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
inactive(1), active(2) |
|
sc800t3NetworkSesBERThreshold |
1.3.6.1.4.1.498.19.1.2.2.1.8 |
When set to thresone(1), the SES BER threshold will be set to
1X10^-6 and when it is set to thresseven(2), it will be set to
7.5X10^-5. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
thresone(1), thresseven(2) |
|
sc800t3InbandLoopback |
1.3.6.1.4.1.498.19.1.2.2.1.9 |
Enables/disables the inband loop back. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabled(2) |
|
sc800t3DiagEntry |
1.3.6.1.4.1.498.19.1.3.1.1 |
The SNMPSC800T3 Diagnostics table entry. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Sc800t3DiagEntry |
|
|
sc800t3DiagIndex |
1.3.6.1.4.1.498.19.1.3.1.1.1 |
Integer value which uniquely identifies the SC800T3 to which this
entry is applicable. SCinstance is defined to be SLDi where:
S (byte value) - physical shelf slot location (01-32)
L (byte value) - line number (01)
D (byte value) - drop number (00)
i (byte value) - interface number (00) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SCinstance |
|
|
sc800t3DiagTestDuration |
1.3.6.1.4.1.498.19.1.3.1.1.2 |
Selects the duration to run a diagnostic test. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
testTime30Secs(1), testTime1Min(2), testTime2Mins(3), testTime3Mins(4), testTime4Mins(5), testTime5Mins(6), testTime6Mins(7), testTime7Mins(8), testTime8Mins(9), testTime9Mins(10), testTime10Mins(11), testTime15Mins(12), testTime20Mins(13), testTime25Mins(14), testTime30Mins(15), testTimeInfinite(16) |
|
sc800t3InsertBitError |
1.3.6.1.4.1.498.19.1.3.1.1.3 |
A set of 2 will insert one bit error for test.
Management may only write a 2. A 1 will always be read. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
insertBitErrorNorm(1), insertOneBitError(2) |
|
sc800t3DiagT3Test |
1.3.6.1.4.1.498.19.1.3.1.1.4 |
A set of 2-11 starts the specified test
and a set of t3NoTest(1) stops the current running test. A
get returns the current active test. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
t3NoTest(1), t3LineLoopback(2), t3PayLoadLoopback(3), t3LocalLoopback(4), t3LocalLoopbackST(5), t3DTELoopback(6), t3RemoteLineLoopback(7), t3RemoteLineLoopbackST(8), t3RemotePayload(9), t3RemotePayloadST(10), t3EndToEndST(11) |
|
sc800t3DiagTestResults |
1.3.6.1.4.1.498.19.1.3.1.1.5 |
Returns a the folowing bytes.
Octet 1 bit 7 - F/U
bit 6 - 1: Test complete
bit 5 - 1: Test aborted
bit 4 - F/U
bit 3 - remote status 0: inactive 1: active
bit 2 - 1: Bit errors over range
bit 1 - Bit Errors
bit 0 - Bit Errors
Octet 2 bit 7 - F/U
bit 6 - 2^13
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9 Bit Error Count
bit 1 - 2^8
bit 0 - 2^7
Octet 3 bit 7 - F/U
bit 6 - 2^6
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(3) |
|
sc800t3DiagResetTestResults |
1.3.6.1.4.1.498.19.1.3.1.1.6 |
This object will clear the results register while
running any test except for Network Delay.
Starting a new test will automatically zero out
the register.
A normal(1) will always be read. Management will set a
resetTestResult(2) to reset the test results.
|
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normal(1), resetTestResult(2) |
|
sc800t3MaintenanceTable |
1.3.6.1.4.1.498.19.1.4.1 |
The table describes the maintenance functions for the sc800t3. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Sc800t3MaintenanceEntry |
|
sc800t3MaintenanceEntry |
1.3.6.1.4.1.498.19.1.4.1.1 |
An entry in the GDC maintenance Table |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Sc800t3MaintenanceEntry |
|
|
sc800t3MaintenanceIndex |
1.3.6.1.4.1.498.19.1.4.1.1.1 |
Integer value which uniquely identifies the SC800T3 to which this
entry is applicable. SCinstance is defined to be SLDi where:
S (byte value) - physical shelf slot location (01-32)
L (byte value) - line number (01)
D (byte value) - drop number (00)
i (byte value) - interface number (00) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SCinstance |
|
|
sc800t3LedStatus |
1.3.6.1.4.1.498.19.1.4.1.1.2 |
Returns a bitwise snapshot of the front panel LED state and front panel switches.
Octet 1 bit 7 - f/u
bit 6 - NTWK 0:LED off 1:LED on
bit 5 - TM 0:LED off 1:LED on
bit 4 - ALM 0:LED off 1:LED on
bit 3 - f/u
bit 2 - f/u
bit 1 - f/u
bit 0 - f/u
Octet 2 bit 7 - f/u
bit 6 - f/u
bit 5 - f/u
bit 4 - f/u
bit 3 - f/u
bit 2 - f/u
bit 1 - f/u
bit 0 - f/u
Octet 3 bit 7 - f/u
bit 6 - f/u
bit 5 - f/u
bit 4 - f/u
bit 3 - f/u
bit 2 - f/u
bit 1 - f/u
bit 0 - f/u
|
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(3) |
|
sc800t3SoftReset |
1.3.6.1.4.1.498.19.1.4.1.1.3 |
Supports the action of soft resetting the unit. When this
object is set to reset(1), then the unit performs a soft reset.
The value norm will be returned when the reset is complete.
The value of norm can not be set by management. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
norm(1), reset(2) |
|
sc800t3DefaultInit |
1.3.6.1.4.1.498.19.1.4.1.1.4 |
This is used to allow the NonVolatile Configuration to be set to
a factory default state. When this value is set to factoryDefault,
the unit will reset to the default configuration. The value of normal
will be returned when the initialization is complete. The value normal
can not be set by management. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normal(1), factoryDefault(2) |
|
sc800t3ValidNearEndIntervals |
1.3.6.1.4.1.498.19.1.4.1.1.5 |
The number of previous near end intervals for which
valid data was collected. The value will be 31
unless the interface was brought on-line within
the last 7.75 hours, in which case the value will
be the number of complete 15 minute intervals
since the interface has been online. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..31 |
|
sc800t3ValidFarEndIntervals |
1.3.6.1.4.1.498.19.1.4.1.1.6 |
The number of previous far end intervals for which
valid data was collected. The value will be 31
unless the interface was brought on-line within
the last 7.75 hours, in which case the value will
be the number of complete 15 minute intervals
since the interface has been online. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..31 |
|
sc800t3ShelfType |
1.3.6.1.4.1.498.19.1.4.1.1.7 |
Type of shelf the sc800t3 is located in. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
spectracomm(1), twinPack(2) |
|
sc800t3TwinPackPowerSupply |
1.3.6.1.4.1.498.19.1.4.1.1.8 |
Power supplies currently installed in Twin Pack. When the sc800t3 is located in
a Spectracomm shelf none(1) will always be returned. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(1), bottomOnly(2), topOnly(3), both(4) |
|
sc800t3TestAllLeds |
1.3.6.1.4.1.498.19.1.4.1.1.9 |
This variable is used to test the front panel leds and individual
segments of the display. A one (1) will turn all leds and display
segments on. They will remain on until a two (2) is set or the card is
rebooted |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
allLedsON(1), allLedsOFF(2) |
|
sc800t3NearEndResetStats |
1.3.6.1.4.1.498.19.1.4.1.1.10 |
Supports the action of soft resetting the sc800t3ValidNearEndIntervals
object. When this object is set to reset(2), then the unit
will reset the sc800t3ValidNearEndIntervals object to zero.
The value of norm(1) can not be set by management. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
norm(1), reset(2) |
|
sc800t3FarEndResetStats |
1.3.6.1.4.1.498.19.1.4.1.1.11 |
Supports the action of soft resetting the sc800t3ValidFarEndIntervals
object. When this object is set to reset(2), then the unit
will reset the sc800t3ValidFarEndIntervals object to zero.
The value of norm(1) can not be set by management. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
norm(1), reset(2) |
|
sc800t3NearEndStatLastInitial |
1.3.6.1.4.1.498.19.1.4.1.1.12 |
Number of seconds from midnight Dec 31 1969 up until sc800t3ValidNearEndIntervals was
last initialized to zero. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..2147483647 |
|
sc800t3FarEndStatLastInitial |
1.3.6.1.4.1.498.19.1.4.1.1.13 |
Number of seconds from midnight Dec 31 1969 up until sc800t3ValidFarEndIntervals was
last initialized to zero. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..2147483647 |
|
sc800t3POSTFail |
1.3.6.1.4.1.498.19.1.5.4 |
OBJECT IDENTIFIER |
|
|
|
sc800t3AIS |
1.3.6.1.4.1.498.19.1.5.10 |
OBJECT IDENTIFIER |
|
|
|
sc800t3RAI |
1.3.6.1.4.1.498.19.1.5.19 |
OBJECT IDENTIFIER |
|
|
|
sc800t3ES |
1.3.6.1.4.1.498.19.1.5.20 |
OBJECT IDENTIFIER |
|
|
|
sc800t3SES |
1.3.6.1.4.1.498.19.1.5.21 |
OBJECT IDENTIFIER |
|
|
|
sc800t3SAS |
1.3.6.1.4.1.498.19.1.5.22 |
OBJECT IDENTIFIER |
|
|
|
sc800t3UAS |
1.3.6.1.4.1.498.19.1.5.23 |
OBJECT IDENTIFIER |
|
|
|
sc800t3AlarmConfigTable |
1.3.6.1.4.1.498.19.1.7.1 |
The sc800t3AlarmConfigTable contains entries that configure alarm
reporting. The structure of the table is such that alarm
configuration is supported on a unit and interface basis, and
then on an alarm type basis within the interface. For
simplicity sake alarms, be they unit or interface
related, are represented in one table. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Sc800t3AlarmConfigEntry |
|
sc800t3AlarmConfigEntry |
1.3.6.1.4.1.498.19.1.7.1.1 |
An entry in the GDC Alarm Configuration table. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Sc800t3AlarmConfigEntry |
|
|
sc800t3AlarmConfigIndex |
1.3.6.1.4.1.498.19.1.7.1.1.1 |
Integer value which uniquely identifies the SC800T3 to which this
entry is applicable. SCinstance is defined to be SLDi where:
S (byte value) - physical shelf slot location (01-32)
L (byte value) - line number (01)
D (byte value) - drop number (00)
i (byte value) - interface number (00) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SCinstance |
|
|
sc800t3AlarmConfigIdentifier |
1.3.6.1.4.1.498.19.1.7.1.1.2 |
format: iso.org.dod.internet.private.enterprises.gdc.
ds3.sc800t3.sc800t3Alarms.ALM
example: 1.3.6.1.4.1.498.19.1.5.ALM
where ALM = 1 for sc800t3NoResponse alarm, 2 for sc800t3DiagRxErr alarm,
etc., as specified in the Alarm Definitions above. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OBJECT IDENTIFIER |
|
|
sc800t3AlarmCountWindow |
1.3.6.1.4.1.498.19.1.7.1.1.3 |
This variable sets/reads the alarm window.
This window is used with the alarm threshold to determine
how long the alarm should be active before reporting. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
reportAll(1), last1sec(2), last1min(3), last1hr(4), reportWhen(5) |
|
sc800t3AlarmCountThreshold |
1.3.6.1.4.1.498.19.1.7.1.1.4 |
This function sets/reads the alarm threshold criteria.
This threshold is used along with the the alarm window to
determine the number of instances in a given time frame for
an alarm to occur before the alarm is considered active. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
thresGT10(1), thresGT100(2), thresGT1000(3), thresGT10000(4), thresGT100000(5), thresGT1000000(6) |
|
sc800t3CurrentNearEndEntry |
1.3.6.1.4.1.498.19.1.6.1.1 |
An entry in the sc800t3 CurrentNearEnd table. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Sc800t3CurrentNearEndEntry |
|
|
sc800t3CurrentNearEndIndex |
1.3.6.1.4.1.498.19.1.6.1.1.1 |
Integer value which uniquely identifies the SC800T3 to which this
entry is applicable. SCinstance is defined to be SLDi where:
S (byte value) - physical shelf slot location (01-32)
L (byte value) - line number (01)
D (byte value) - drop number (00)
i (byte value) - interface number (00) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SCinstance |
|
|
sc800t3CurrentNearEndStat |
1.3.6.1.4.1.498.19.1.6.1.1.2 |
Returns a bitwise snapshot of the statistics.
Octet 1 bit 7 - parity
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - 2^9 Errored Seconds (ES)
bit 1 - 2^8
bit 0 - 2^7
Octet 2 bit 7 - parity
bit 6 - 2^6 Errored Seconds (ES)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 3 bit 7 - parity Severely Errored Seconds (SES)
bit 6 - Invalid Data Flag
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 4 bit 7 - parity Severely Errored Frames (SAS)
bit 6 - Invalid Data Flag
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 5 bit 7 - parity Unavailable Seconds (UAS)
bit 6 - Invalid Data Flag
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 6 bit 7 - parity Code Violations (CV)
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - n/a
bit 1 - n/a
bit 0 - n/a
Octet 7 bit 7 - parity
bit 6 - 2^13 Code Violations (CV)
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 8 bit 7 - parity
bit 6 - 2^6 Code Violations (CV)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 9 bit 7 - parity
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - 2^9 Errored Seconds Line (ESl)
bit 1 - 2^8
bit 0 - 2^7
Octet 10 bit 7 - parity
bit 6 - 2^6 Errored Seconds Line (ESl)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 11 bit 7 - parity
bit 6 - 2^6 Percent Complete
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(11) |
|
sc800t3CurrentFarEndEntry |
1.3.6.1.4.1.498.19.1.6.3.1 |
An entry in the sc800t3 CurrentFarEnd table. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Sc800t3CurrentFarEndEntry |
|
|
sc800t3CurrentFarEndIndex |
1.3.6.1.4.1.498.19.1.6.3.1.1 |
Integer value which uniquely identifies the SC800T3 to which this
entry is applicable. SCinstance is defined to be SLDi where:
S (byte value) - physical shelf slot location (01-32)
L (byte value) - line number (01)
D (byte value) - drop number (00)
i (byte value) - interface number (00) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SCinstance |
|
|
sc800t3CurrentFarEndStat |
1.3.6.1.4.1.498.19.1.6.3.1.2 |
Returns a bitwise snapshot of the statistics.
Octet 1 bit 7 - parity
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - 2^9 Errored Seconds (ES)
bit 1 - 2^8
bit 0 - 2^7
Octet 2 bit 7 - parity
bit 6 - 2^6 Errored Seconds (ES)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 3 bit 7 - parity Severely Errored Seconds (SES)
bit 6 - Invalid Data Flag
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 4 bit 7 - parity Severely Errored Frames (SAS)
bit 6 - Invalid Data Flag
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 5 bit 7 - parity Unavailable Seconds (UAS)
bit 6 - Invalid Data Flag
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 6 bit 7 - parity Code Violations (CV)
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - n/a
bit 1 - n/a
bit 0 - n/a
Octet 7 bit 7 - parity
bit 6 - 2^13 Code Violations (CV)
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 8 bit 7 - parity
bit 6 - 2^6 Code Violations (CV)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 9 bit 7 - parity
bit 6 - 2^6 Percent Complete
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(9) |
|
sc800t3CurrentDayNearEndEntry |
1.3.6.1.4.1.498.19.1.6.4.1 |
An entry in the sc800t3 CurrentDayNearEndTable. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Sc800t3CurrentDayNearEndEntry |
|
|
sc800t3CurrentDayNearEndIndex |
1.3.6.1.4.1.498.19.1.6.4.1.1 |
Integer value which uniquely identifies the SC800T3 to which this
entry is applicable. SCinstance is defined to be SLDi where:
S (byte value) - physical shelf slot location (01-32)
L (byte value) - line number (01)
D (byte value) - drop number (00)
i (byte value) - interface number (00) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SCinstance |
|
|
sc800t3CurrentDayNearEndStat |
1.3.6.1.4.1.498.19.1.6.4.1.2 |
Returns a bitwise snapshot of the statistics.
Octet 1 bit 7 - parity
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - n/a
bit 1 - 2^15 Errored Seconds (ES)
bit 0 - 2^14
Octet 2 bit 7 - parity
bit 6 - 2^13 Errored Seconds (ES)
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 3 bit 7 - parity
bit 6 - 2^6 Errored Seconds (ES)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 4 bit 7 - parity Severely Errored Seconds (SES)
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 5 bit 7 - parity
bit 6 - 2^6 Severely Errored Seconds (SES)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 6 bit 7 - parity Severely Errored Frame (SAS)
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 7 bit 7 - parity
bit 6 - 2^6 Severely Errored Frame (SAS)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 8 bit 7 - parity Unavailable Seconds (UAS)
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 9 bit 7 - parity
bit 6 - 2^6 Unavailable Seconds (UAS)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 10 bit 7 - parity Code Violations (CV)
bit 6 - Invalid Data Flag
bit 5 - 2^19
bit 4 - 2^18
bit 3 - 2^17
bit 2 - 2^16
bit 1 - 2^15
bit 0 - 2^14
Octet 11 bit 7 - parity
bit 6 - 2^13 Code Violations (CV)
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 12 bit 7 - parity
bit 6 - 2^6 Code Violations (CV)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 13 bit 7 - parity
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - n/a
bit 1 - 2^15 Errored Seconds Line (ESl)
bit 0 - 2^14
Octet 14 bit 7 - parity
bit 6 - 2^13 Errored Seconds Line (ESl)
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 15 bit 7 - parity
bit 6 - 2^6 Errored Seconds Line (ESl)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 16 bit 7 - parity
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - n/a
bit 1 - 2^15 FC-P Path Failure Events
bit 0 - 2^14
Octet 17 bit 7 - parity
bit 6 - 2^13 FC-P Path Failure Events
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 18 bit 7 - parity
bit 6 - 2^6 FC-P Path Failure Events
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(18) |
|
sc800t3CurrentDayFarEndEntry |
1.3.6.1.4.1.498.19.1.6.6.1 |
An entry in the sc800t3CurrentDayFarEndTable. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Sc800t3CurrentDayFarEndEntry |
|
|
sc800t3CurrentDayFarEndIndex |
1.3.6.1.4.1.498.19.1.6.6.1.1 |
Integer value which uniquely identifies the SC800T3 to which this
entry is applicable. SCinstance is defined to be SLDi where:
S (byte value) - physical shelf slot location (01-32)
L (byte value) - line number (01)
D (byte value) - drop number (00)
i (byte value) - interface number (00) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SCinstance |
|
|
sc800t3CurrentDayFarEndStat |
1.3.6.1.4.1.498.19.1.6.6.1.2 |
Returns a bitwise snapshot of the statistics.
Octet 1 bit 7 - parity
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - n/a
bit 1 - 2^15 Errored Seconds (ES)
bit 0 - 2^14
Octet 2 bit 7 - parity
bit 6 - 2^13 Errored Seconds (ES)
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 3 bit 7 - parity
bit 6 - 2^6 Errored Seconds (ES)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 4 bit 7 - parity Severely Errored Seconds (SES)
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 5 bit 7 - parity
bit 6 - 2^6 Severely Errored Seconds (SES)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 6 bit 7 - parity Severely Errored Frame (SAS)
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 7 bit 7 - parity
bit 6 - 2^6 Severely Errored Frame (SAS)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 8 bit 7 - parity Unavailable Seconds (UAS)
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 9 bit 7 - parity
bit 6 - 2^6 Unavailable Seconds (UAS)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 10 bit 7 - parity Code Violations (CV)
bit 6 - Invalid Data Flag
bit 5 - 2^19
bit 4 - 2^18
bit 3 - 2^17
bit 2 - 2^16
bit 1 - 2^15
bit 0 - 2^14
Octet 11 bit 7 - parity
bit 6 - 2^13 Code Violations (CV)
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 12 bit 7 - parity
bit 6 - 2^6 Code Violations (CV)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 13 bit 7 - parity FCCP-PFE Path Failure Events
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - n/a
bit 1 - 2^15
bit 0 - 2^14
Octet 14 bit 7 - parity
bit 6 - 2^13 FCCP-PFE Path Failure Events
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 15 bit 7 - parity
bit 6 - 2^6 FCCP-PFE Path Failure Events
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(15) |
|
sc800t3PreviousDayNearEndEntry |
1.3.6.1.4.1.498.19.1.6.2.1 |
An entry in the sc800t3 PreviousDayNearEndTable. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Sc800t3PreviousDayNearEndEntry |
|
|
sc800t3PreviousDayNearEndIndex |
1.3.6.1.4.1.498.19.1.6.2.1.1 |
Integer value which uniquely identifies the SC800T3 to which this
entry is applicable. SCinstance is defined to be SLDi where:
S (byte value) - physical shelf slot location (01-32)
L (byte value) - line number (01)
D (byte value) - drop number (00)
i (byte value) - interface number (00) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SCinstance |
|
|
sc800t3PreviousDayNearEndStat |
1.3.6.1.4.1.498.19.1.6.2.1.2 |
Returns a bitwise snapshot of the statistics.
Octet 1 bit 7 - parity
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - n/a
bit 1 - 2^15 Errored Seconds (ES)
bit 0 - 2^14
Octet 2 bit 7 - parity
bit 6 - 2^13 Errored Seconds (ES)
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 3 bit 7 - parity
bit 6 - 2^6 Errored Seconds (ES)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 4 bit 7 - parity Severely Errored Seconds (SES)
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 5 bit 7 - parity
bit 6 - 2^6 Severely Errored Seconds (SES)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 6 bit 7 - parity Severely Errored Frame (SAS)
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 7 bit 7 - parity
bit 6 - 2^6 Severely Errored Frame (SAS)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 8 bit 7 - parity Unavailable Seconds (UAS)
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 9 bit 7 - parity
bit 6 - 2^6 Unavailable Seconds (UAS)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 10 bit 7 - parity Code Violations (CV)
bit 6 - Invalid Data Flag
bit 5 - 2^19
bit 4 - 2^18
bit 3 - 2^17
bit 2 - 2^16
bit 1 - 2^15
bit 0 - 2^14
Octet 11 bit 7 - parity
bit 6 - 2^13 Code Violations (CV)
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 12 bit 7 - parity
bit 6 - 2^6 Code Violations (CV)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 13 bit 7 - parity
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - n/a
bit 1 - 2^15 Errored Seconds Line (ESl)
bit 0 - 2^14
Octet 14 bit 7 - parity
bit 6 - 2^13 Errored Seconds Line (ESl)
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 15 bit 7 - parity
bit 6 - 2^6 Errored Seconds Line (ESl)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 16 bit 7 - parity
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - n/a
bit 1 - 2^15 FC-P Path Failure Events
bit 0 - 2^14
Octet 17 bit 7 - parity
bit 6 - 2^13 FC-P Path Failure Events
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 18 bit 7 - parity
bit 6 - 2^6 FC-P Path Failure Events
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(18) |
|
sc800t3PreviousDayFarEndEntry |
1.3.6.1.4.1.498.19.1.6.5.1 |
An entry in the sc800t3PreviousDayFarEndTable. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Sc800t3PreviousDayFarEndEntry |
|
|
sc800t3PreviousDayFarEndIndex |
1.3.6.1.4.1.498.19.1.6.5.1.1 |
Integer value which uniquely identifies the SC800T3 to which this
entry is applicable. SCinstance is defined to be SLDi where:
S (byte value) - physical shelf slot location (01-32)
L (byte value) - line number (01)
D (byte value) - drop number (00)
i (byte value) - interface number (00) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SCinstance |
|
|
sc800t3PreviousDayFarEndStat |
1.3.6.1.4.1.498.19.1.6.5.1.2 |
Returns a bitwise snapshot of the statistics.
Octet 1 bit 7 - parity
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - n/a
bit 1 - 2^15 Errored Seconds (ES)
bit 0 - 2^14
Octet 2 bit 7 - parity
bit 6 - 2^13 Errored Seconds (ES)
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 3 bit 7 - parity
bit 6 - 2^6 Errored Seconds (ES)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 4 bit 7 - parity Severely Errored Seconds (SES)
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 5 bit 7 - parity
bit 6 - 2^6 Severely Errored Seconds (SES)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 6 bit 7 - parity Severely Errored Frame (SAS)
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 7 bit 7 - parity
bit 6 - 2^6 Severely Errored Frame (SAS)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 8 bit 7 - parity Unavailable Seconds (UAS)
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 9 bit 7 - parity
bit 6 - 2^6 Unavailable Seconds (UAS)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 10 bit 7 - parity Code Violations (CV)
bit 6 - Invalid Data Flag
bit 5 - 2^19
bit 4 - 2^18
bit 3 - 2^17
bit 2 - 2^16
bit 1 - 2^15
bit 0 - 2^14
Octet 11 bit 7 - parity
bit 6 - 2^13 Code Violations (CV)
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 12 bit 7 - parity
bit 6 - 2^6 Code Violations (CV)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 13 bit 7 - parity FCCP-PFE Path Failure Events
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - n/a
bit 1 - 2^15
bit 0 - 2^14
Octet 14 bit 7 - parity
bit 6 - 2^13 FCCP-PFE Path Failure Events
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 15 bit 7 - parity
bit 6 - 2^6 FCCP-PFE Path Failure Events
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(15) |
|
sc800t3NearEndIntervalEntry |
1.3.6.1.4.1.498.19.1.6.7.1 |
An entry in the Interval table. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Sc800t3NearEndIntervalEntry |
|
|
sc800t3NearEndIntervalIndex |
1.3.6.1.4.1.498.19.1.6.7.1.1 |
Integer value which uniquely identifies the SC800T3 to which this
entry is applicable. SCinstance is defined to be SLDi where:
S (byte value) - physical shelf slot location (01-32)
L (byte value) - line number (01)
D (byte value) - drop number (00)
i (byte value) - interface number (00) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SCinstance |
|
|
sc800t3NearEndIntervalNumber |
1.3.6.1.4.1.498.19.1.6.7.1.2 |
A number between 1 and 31, where 1 is the most recently completed
minute interval and 31 is the least recently completed 15 minutes
interval (assuming that all 31 intervals are valid). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..31 |
|
sc800t3NearEndIntervalStats |
1.3.6.1.4.1.498.19.1.6.7.1.3 |
Returns a bitwise snapshot of the statistics.
Octet 1 bit 7 - parity
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - 2^9 Errored Seconds (ES)
bit 1 - 2^8
bit 0 - 2^7
Octet 2 bit 7 - parity
bit 6 - 2^6 Errored Seconds (ES)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 3 bit 7 - parity Severely Errored Seconds (SES)
bit 6 - Invalid Data Flag
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 4 bit 7 - parity Severely Errored Frames (SAS)
bit 6 - Invalid Data Flag
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 5 bit 7 - parity Unavailable Seconds (UAS)
bit 6 - Invalid Data Flag
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 6 bit 7 - parity Code Violations (CV)
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - n/a
bit 1 - n/a
bit 0 - n/a
Octet 7 bit 7 - parity
bit 6 - 2^13 Code Violations (CV)
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 8 bit 7 - parity
bit 6 - 2^6 Code Violations (CV)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 9 bit 7 - parity
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - 2^9 Errored Seconds Line (ESl)
bit 1 - 2^8
bit 0 - 2^7
Octet 10 bit 7 - parity
bit 6 - 2^6 Errored Seconds Line (ESl)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 11 bit 7 - parity
bit 6 - n/a Interval (1-31)
bit 5 - n/a
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(11) |
|
sc800t3FarEndIntervalEntry |
1.3.6.1.4.1.498.19.1.6.9.1 |
An entry in the Interval table. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Sc800t3FarEndIntervalEntry |
|
|
sc800t3FarEndIntervalIndex |
1.3.6.1.4.1.498.19.1.6.9.1.1 |
Integer value which uniquely identifies the SC800T3 to which this
entry is applicable. SCinstance is defined to be SLDi where:
S (byte value) - physical shelf slot location (01-32)
L (byte value) - line number (01)
D (byte value) - drop number (00)
i (byte value) - interface number (00) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SCinstance |
|
|
sc800t3FarEndIntervalNumber |
1.3.6.1.4.1.498.19.1.6.9.1.2 |
A number between 1 and 31, where 1 is the most recently completed
minute interval and 31 is the least recently completed 15 minutes
interval (assuming that all 31 intervals are valid). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..31 |
|
sc800t3FarEndIntervalStats |
1.3.6.1.4.1.498.19.1.6.9.1.3 |
Returns a bitwise snapshot of the statistics.
Octet 1 bit 7 - parity
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - 2^9 Errored Seconds (ES)
bit 1 - 2^8
bit 0 - 2^7
Octet 2 bit 7 - parity
bit 6 - 2^6 Errored Seconds (ES)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 3 bit 7 - parity Severely Errored Seconds (SES)
bit 6 - Invalid Data Flag
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 4 bit 7 - parity Severely Errored Frames (SAS)
bit 6 - Invalid Data Flag
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 5 bit 7 - parity Unavailable Seconds (UAS)
bit 6 - Invalid Data Flag
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 6 bit 7 - parity Code Violations (CV)
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - n/a
bit 1 - n/a
bit 0 - n/a
Octet 7 bit 7 - parity
bit 6 - 2^13 Code Violations (CV)
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 8 bit 7 - parity
bit 6 - 2^6 Code Violations (CV)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 9 bit 7 - parity
bit 6 - n/a Interval (1-31)
bit 5 - n/a
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(9) |
|
sc800t3PreviousNearEndEntry |
1.3.6.1.4.1.498.19.1.6.10.1 |
An entry in the sc800t3 PreviousNearEnd table. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Sc800t3PreviousNearEndEntry |
|
|
sc800t3PreviousNearEndIndex |
1.3.6.1.4.1.498.19.1.6.10.1.1 |
Integer value which uniquely identifies the SC800T3 to which this
entry is applicable. SCinstance is defined to be SLDi where:
S (byte value) - physical shelf slot location (01-32)
L (byte value) - line number (01)
D (byte value) - drop number (00)
i (byte value) - interface number (00) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SCinstance |
|
|
sc800t3PreviousNearEndStat |
1.3.6.1.4.1.498.19.1.6.10.1.2 |
Returns a bitwise snapshot of the statistics.
Octet 1 bit 7 - f/u
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - 2^9 Errored Seconds (ES)
bit 1 - 2^8
bit 0 - 2^7
Octet 2 bit 7 - f/u
bit 6 - 2^6 Errored Seconds (ES)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 3 bit 7 - f/u Severely Errored Seconds (SES)
bit 6 - Invalid Data Flag
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 4 bit 7 - f/u Severely Errored Frames (SAS)
bit 6 - Invalid Data Flag
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 5 bit 7 - f/u Unavailable Seconds (UAS)
bit 6 - Invalid Data Flag
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 6 bit 7 - f/u Code Violations (CV)
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - n/a
bit 1 - n/a
bit 0 - n/a
Octet 7 bit 7 - f/u
bit 6 - 2^13 Code Violations (CV)
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 8 bit 7 - f/u
bit 6 - 2^6 Code Violations (CV)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 9 bit 7 - fu
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - 2^9 Errored Seconds Line (ESl)
bit 1 - 2^8
bit 0 - 2^7
Octet 10 bit 7 - f/u
bit 6 - 2^6 Errored Seconds Line (ESl)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 11 bit 7 - f/u
bit 6 - 2^6 Percent Complete
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(11) |
|
sc800t3PreviousFarEndEntry |
1.3.6.1.4.1.498.19.1.6.11.1 |
An entry in the sc800t3 PreviousFarEnd table. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Sc800t3PreviousFarEndEntry |
|
|
sc800t3PreviousFarEndIndex |
1.3.6.1.4.1.498.19.1.6.11.1.1 |
Integer value which uniquely identifies the SC800T3 to which this
entry is applicable. SCinstance is defined to be SLDi where:
S (byte value) - physical shelf slot location (01-32)
L (byte value) - line number (01)
D (byte value) - drop number (00)
i (byte value) - interface number (00) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SCinstance |
|
|
sc800t3PreviousFarEndStat |
1.3.6.1.4.1.498.19.1.6.11.1.2 |
Returns a bitwise snapshot of the statistics.
Octet 1 bit 7 - f/u
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - 2^9 Errored Seconds (ES)
bit 1 - 2^8
bit 0 - 2^7
Octet 2 bit 7 - f/u
bit 6 - 2^6 Errored Seconds (ES)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 3 bit 7 - f/u Severely Errored Seconds (SES)
bit 6 - Invalid Data Flag
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 4 bit 7 - f/u Severely Errored Frames (SAS)
bit 6 - Invalid Data Flag
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 5 bit 7 - f/u Unavailable Seconds (UAS)
bit 6 - Invalid Data Flag
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0
Octet 6 bit 7 - f/u Code Violations (CV)
bit 6 - Invalid Data Flag
bit 5 - n/a
bit 4 - n/a
bit 3 - n/a
bit 2 - n/a
bit 1 - n/a
bit 0 - n/a
Octet 7 bit 7 - f/u
bit 6 - 2^13 Code Violations (CV)
bit 5 - 2^12
bit 4 - 2^11
bit 3 - 2^10
bit 2 - 2^9
bit 1 - 2^8
bit 0 - 2^7
Octet 8 bit 7 - f/u
bit 6 - 2^6 Code Violations (CV)
bit 5 - 2^5
bit 4 - 2^4
bit 3 - 2^3
bit 2 - 2^2
bit 1 - 2^1
bit 0 - 2^0 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(8) |
|
sc800t3LocalAlarmConfigTable |
1.3.6.1.4.1.498.19.1.8.1 |
The sc800t3LocalAlarmConfigTable contains entries that configure
alarm
reporting. The structure of the table is such that alarm
configuration is supported on a unit and interface basis, and
then on an alarm type basis within the interface. For
simplicity sake alarms, be they unit or interface
related, are represented in one table. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Sc800t3LocalAlarmConfigEntry |
|
sc800t3LocalAlarmConfigEntry |
1.3.6.1.4.1.498.19.1.8.1.1 |
An entry in the GDC Local Alarm Configuration table. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Sc800t3LocalAlarmConfigEntry |
|
|
sc800t3LocalAlarmConfigIndex |
1.3.6.1.4.1.498.19.1.8.1.1.1 |
The index value which uniquely identifies the interface to
which this entry is applicable. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SCinstance |
|
|
sc800t3OOF |
1.3.6.1.4.1.498.19.1.8.1.1.2 |
Disables or enables the alarm on the Major buss or Minor
buss. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabledMajor(2), enabledMinor(3) |
|
sc800t3AISLOCAL |
1.3.6.1.4.1.498.19.1.8.1.1.3 |
Disables or enables the alarm on the Major buss or Minor
buss. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabledMajor(2), enabledMinor(3) |
|
sc800t3TIMLOS |
1.3.6.1.4.1.498.19.1.8.1.1.4 |
Disables or enables the alarm on the Major buss or Minor
buss. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabledMajor(2), enabledMinor(3) |
|
sc800t3TXDLOS |
1.3.6.1.4.1.498.19.1.8.1.1.5 |
Disables or enables the alarm on the Major buss or Minor
buss. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabledMajor(2), enabledMinor(3) |
|
sc800t3RXDLOS |
1.3.6.1.4.1.498.19.1.8.1.1.6 |
Disables or enables the alarm on the Major buss or Minor
buss. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabledMajor(2), enabledMinor(3) |
|
sc800t3LOS |
1.3.6.1.4.1.498.19.1.8.1.1.7 |
Disables or enables the alarm on the Major buss or Minor
buss. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabledMajor(2), enabledMinor(3) |
|
sc800t3TPSFAIL |
1.3.6.1.4.1.498.19.1.8.1.1.8 |
Disables or enables the alarm on the Major buss or Minor
buss. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabledMajor(2), enabledMinor(3) |
|
sc800t3BPSFAIL |
1.3.6.1.4.1.498.19.1.8.1.1.9 |
Disables or enables the alarm on the Major buss or Minor
buss. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabledMajor(2), enabledMinor(3) |
|
sc800t3DTECLKLOS |
1.3.6.1.4.1.498.19.1.8.1.1.10 |
Disables or enables the alarm on the Major buss or Minor
buss. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabledMajor(2), enabledMinor(3) |
|
sc800t3DTERDYLOS |
1.3.6.1.4.1.498.19.1.8.1.1.11 |
Disables or enables the alarm on the Major buss or Minor
buss. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabledMajor(2), enabledMinor(3) |
|
sc800t3RAILOCAL |
1.3.6.1.4.1.498.19.1.8.1.1.12 |
Disables or enables the alarm on the Major buss or Minor
buss. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabledMajor(2), enabledMinor(3) |
|
sc800t3THRESHESL |
1.3.6.1.4.1.498.19.1.8.1.1.13 |
Disables or enables the alarm on the Major buss or Minor
buss. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabledMajor(2), enabledMinor(3) |
|
sc800t3THRESHES |
1.3.6.1.4.1.498.19.1.8.1.1.14 |
Disables or enables the alarm on the Major buss or Minor
buss. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabledMajor(2), enabledMinor(3) |
|
sc800t3THRESHSES |
1.3.6.1.4.1.498.19.1.8.1.1.15 |
Disables or enables the alarm on the Major buss or Minor
buss. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabledMajor(2), enabledMinor(3) |
|
sc800t3THRESHSAS |
1.3.6.1.4.1.498.19.1.8.1.1.16 |
Disables or enables the alarm on the Major buss or Minor
buss. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabledMajor(2), enabledMinor(3) |
|
sc800t3THRESHUAS |
1.3.6.1.4.1.498.19.1.8.1.1.17 |
Disables or enables the alarm on the Major buss or Minor
buss. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabledMajor(2), enabledMinor(3) |
|
sc800t3THRESHCV |
1.3.6.1.4.1.498.19.1.8.1.1.18 |
Disables or enables the alarm on the Major buss or Minor
buss. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), enabledMajor(2), enabledMinor(3) |
|