G6-NTP-MIB

File: G6-NTP-MIB.mib (6354 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC MICROSENS-G6-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
Unsigned32 Counter32 enterprises
NOTIFICATION-TYPE DisplayString MacAddress
g6

Defined Values

management 1.3.6.1.4.1.3181.10.6.3
Microsens private MIB for Generation 6 Ethernet Switches
MODULE-IDENTITY    

ntp 1.3.6.1.4.1.3181.10.6.3.73
OBJECT IDENTIFIER    

ntpEnableNtp 1.3.6.1.4.1.3181.10.6.3.73.1
When enabled the local clock will be synchronized with the time provided by a time server.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

ntpSyncNow 1.3.6.1.4.1.3181.10.6.3.73.2
Action command to read time server now and setup the internal clock.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ntpDhcpProvidesNtpServer 1.3.6.1.4.1.3181.10.6.3.73.3
Enable DHCP to automatically retrieve NTP server address(es). When disabled, the locally defined addresses are used instead.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

ntpMainNtpServer 1.3.6.1.4.1.3181.10.6.3.73.4
This is the preferred NTP server address. IP address or symbolic name may be used.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ntpBackupNtpServer 1.3.6.1.4.1.3181.10.6.3.73.5
This defines an optional alternate ntp server address. IP address or symbolic name may be used.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ntpTrustedServer 1.3.6.1.4.1.3181.10.6.3.73.6
Some NTP server (Windows) indicate a too large deviation or indicate they are unreliable when they are not externally synchronized. To be able to still use such a server set this option to true.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

ntpSyncInterval 1.3.6.1.4.1.3181.10.6.3.73.7
Resynchronization interval (minutes), default once per day.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

ntpShowTimeDate 1.3.6.1.4.1.3181.10.6.3.73.8
Show system time and date.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ntpListTimeZones 1.3.6.1.4.1.3181.10.6.3.73.9
Displays a long list of available timezones. Pick the timezone that matches your location and use this name for the time_zone parameter.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ntpTimeZone 1.3.6.1.4.1.3181.10.6.3.73.10
Enter a string exactly as obtained via list_time_zones command. Note that a change of the time zone if only effective after a system reboot.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ntpTimeFormat 1.3.6.1.4.1.3181.10.6.3.73.11
This parameter permits definition of the time format displayed under ntp.local_time. When left blank the default format hrs:min:sec is used. The parameter follows the Linux date command syntax. Please refer to external documentation for details. Use %k:%M for time without seconds. Use %P to add AM/PM where is applies. There are more options.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ntpDateFormat 1.3.6.1.4.1.3181.10.6.3.73.12
This parameter permits definition of the data format displayed under ntp.local_date. When left blank the default format year-month-date is used. The parameter follows the Linux date command syntax. Please refer to external documentation for details. It is also possible to add weekday %A or month %B or week of year %V, etc.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ntpStatus 1.3.6.1.4.1.3181.10.6.3.73.100
Indicates by which means the clock was last set.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unset(0), manuallySet(1), synchronized(2), syncFailed(4), dayLightSavingTime(16)  

ntpLocalTime 1.3.6.1.4.1.3181.10.6.3.73.101
Displays the current local date according to selected time zone in the format defined user ntp.time_format.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ntpLocalDate 1.3.6.1.4.1.3181.10.6.3.73.102
Displays the current local date according to selected time zone in the format defined user ntp.date_format.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ntpUsedNtpServer 1.3.6.1.4.1.3181.10.6.3.73.103
Actually used ntp server IP address or name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ntpDynamicNtpServer1 1.3.6.1.4.1.3181.10.6.3.73.104
Main dynamically assigned ntp server IP address.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

ntpDynamicNtpServer2 1.3.6.1.4.1.3181.10.6.3.73.105
Alternate dynamically assigned ntp server IP address.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

ntpDynamicNtpServer3 1.3.6.1.4.1.3181.10.6.3.73.106
Alternate dynamically assigned ntp server IP address.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

ntpDynamicNtpServer4 1.3.6.1.4.1.3181.10.6.3.73.107
Alternate dynamically assigned ntp server IP address.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..20)