G6-MSP1000-MIB

File: G6-MSP1000-MIB.mib (92858 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC MICROSENS-G6-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
Unsigned32 Counter32 enterprises
NOTIFICATION-TYPE DisplayString MacAddress
g6

Defined Types

SystemConfigEntry  
SEQUENCE    
  systemConfigIndex INTEGER
  systemConfigNmsOperationMode INTEGER
  systemConfigCoreMode INTEGER
  systemConfigNodeId Unsigned32
  systemConfigDisableLegacyAccess INTEGER

SlotConfigEntry  
SEQUENCE    
  slotConfigIndex INTEGER
  slotConfigModule INTEGER
  slotConfigSparepartMode INTEGER
  slotConfigPort1Alias DisplayString
  slotConfigPort2Alias DisplayString
  slotConfigPort3Alias DisplayString
  slotConfigPort4Alias DisplayString

X2gConfigEntry  
SEQUENCE    
  x2gConfigIndex INTEGER
  x2gConfigPort1Datarate INTEGER
  x2gConfigPort2Datarate INTEGER
  x2gConfigPort3Datarate INTEGER
  x2gConfigPort4Datarate INTEGER
  x2gConfigCrossConnect INTEGER
  x2gConfigDeactivatePort1 INTEGER
  x2gConfigDeactivatePort2 INTEGER
  x2gConfigDeactivatePort3 INTEGER
  x2gConfigDeactivatePort4 INTEGER
  x2gConfigFrontPanelMode INTEGER
  x2gConfigLossOfSignalHandling INTEGER
  x2gConfigOptimizedFor8b10b INTEGER
  x2gConfigBertPattern INTEGER
  x2gConfigSfpDeltaInterval INTEGER
  x2gConfigSfpDeltaThreshold INTEGER
  x2gConfigBackupTrigger INTEGER
  x2gConfigStayWithLastLink INTEGER
  x2gConfigBackupEnd INTEGER
  x2gConfigPermitLinkOverride INTEGER

TxgConfigEntry  
SEQUENCE    
  txgConfigIndex INTEGER
  txgConfigTxgDatarate INTEGER
  txgConfigTxgOperationMode INTEGER
  txgConfigPort1ItuChannel INTEGER
  txgConfigPort2ItuChannel INTEGER
  txgConfigDeactivatePort1 INTEGER
  txgConfigDeactivatePort2 INTEGER
  txgConfigFrontPanelMode INTEGER
  txgConfigLossOfSignalHandling INTEGER
  txgConfigBertPattern INTEGER
  txgConfigSfpDeltaInterval INTEGER
  txgConfigSfpDeltaThreshold INTEGER

CxgPlusConfigEntry  
SEQUENCE    
  cxgPlusConfigIndex INTEGER
  cxgPlusConfigCxgPort12Datarate INTEGER
  cxgPlusConfigCxgPort34Datarate INTEGER
  cxgPlusConfigPort1ItuChannel INTEGER
  cxgPlusConfigPort2ItuChannel INTEGER
  cxgPlusConfigPort3ItuChannel INTEGER
  cxgPlusConfigPort4ItuChannel INTEGER
  cxgPlusConfigDeactivatePort1 INTEGER
  cxgPlusConfigDeactivatePort2 INTEGER
  cxgPlusConfigDeactivatePort3 INTEGER
  cxgPlusConfigDeactivatePort4 INTEGER
  cxgPlusConfigFrontPanelMode INTEGER
  cxgPlusConfigLossOfSignalHandling INTEGER
  cxgPlusConfigSfpDeltaInterval INTEGER
  cxgPlusConfigSfpDeltaThreshold INTEGER

CxgConfigEntry  
SEQUENCE    
  cxgConfigIndex INTEGER
  cxgConfigCxgPort12Datarate INTEGER
  cxgConfigPort1ItuChannel INTEGER
  cxgConfigPort2ItuChannel INTEGER
  cxgConfigDeactivatePort1 INTEGER
  cxgConfigDeactivatePort2 INTEGER
  cxgConfigFrontPanelMode INTEGER
  cxgConfigLossOfSignalHandling INTEGER
  cxgConfigSfpDeltaInterval INTEGER
  cxgConfigSfpDeltaThreshold INTEGER

T4gConfigEntry  
SEQUENCE    
  t4gConfigIndex INTEGER
  t4gConfigT4gPort12Datarate INTEGER
  t4gConfigT4gPort34Datarate INTEGER
  t4gConfigT4gOperationMode INTEGER
  t4gConfigDeactivatePort1 INTEGER
  t4gConfigDeactivatePort2 INTEGER
  t4gConfigDeactivatePort3 INTEGER
  t4gConfigDeactivatePort4 INTEGER
  t4gConfigFrontPanelMode INTEGER
  t4gConfigLossOfSignalHandling INTEGER
  t4gConfigBertPattern INTEGER
  t4gConfigSfpDeltaInterval INTEGER
  t4gConfigSfpDeltaThreshold INTEGER

M2gConfigEntry  
SEQUENCE    
  m2gConfigIndex INTEGER
  m2gConfigChannel1Datarate INTEGER
  m2gConfigChannel2Datarate INTEGER
  m2gConfigPort1CopperSfp INTEGER
  m2gConfigPort2CopperSfp INTEGER
  m2gConfigSfpDeltaInterval INTEGER
  m2gConfigSfpDeltaThreshold INTEGER
  m2gConfigLinkBackupTrigger INTEGER
  m2gConfigStayWithLastLink INTEGER
  m2gConfigBackupEnd INTEGER
  m2gConfigPermitLinkOverride INTEGER

Om1ConfigEntry  
SEQUENCE    
  om1ConfigIndex INTEGER
  om1ConfigWavelengthPortA INTEGER
  om1ConfigLowThresholdPortA DisplayString
  om1ConfigHighThresholdPortA DisplayString
  om1ConfigWavelengthPortB INTEGER
  om1ConfigLowThresholdPortB DisplayString
  om1ConfigHighThresholdPortB DisplayString
  om1ConfigFrontPanelMode INTEGER

Lp1ConfigEntry  
SEQUENCE    
  lp1ConfigIndex INTEGER
  lp1ConfigWavelengthPortA INTEGER
  lp1ConfigLowThresholdPortA DisplayString
  lp1ConfigHighThresholdPortA DisplayString
  lp1ConfigWavelengthPortB INTEGER
  lp1ConfigLowThresholdPortB DisplayString
  lp1ConfigHighThresholdPortB DisplayString
  lp1ConfigBackupCriteria INTEGER
  lp1ConfigStayWithLastLink INTEGER
  lp1ConfigBackupEnd INTEGER
  lp1ConfigFrontPanelMode INTEGER

EmConfigEntry  
SEQUENCE    
  emConfigIndex INTEGER
  emConfigEdfaOperationMode INTEGER
  emConfigLossOfSignalHandling INTEGER
  emConfigSignalGain DisplayString
  emConfigMaxOutputPower DisplayString
  emConfigLowThresholdEdfaIn DisplayString
  emConfigHighThresholdEdfaIn DisplayString
  emConfigLowThresholdPortB DisplayString
  emConfigHighThresholdPortB DisplayString
  emConfigFrontPanelMode INTEGER

ModuleControlEntry  
SEQUENCE    
  moduleControlIndex INTEGER
  moduleControlEnterPassword DisplayString
  moduleControlRebootModule DisplayString
  moduleControlWarmStart DisplayString
  moduleControlClearCounter DisplayString
  moduleControlSwitchOffBackup DisplayString
  moduleControlSwitchToBackup DisplayString
  moduleControlAutomaticBackup DisplayString
  moduleControlWriteDisplay DisplayString
  moduleControlLedTest DisplayString
  moduleControlLoopOff DisplayString
  moduleControlLoopPort1 DisplayString
  moduleControlLoopPort2 DisplayString
  moduleControlLoopPort3 DisplayString
  moduleControlLoopPort4 DisplayString
  moduleControlBertRestart DisplayString
  moduleControlBertInsertError DisplayString
  moduleControlBertClearCounter DisplayString

SystemStatusEntry  
SEQUENCE    
  systemStatusIndex INTEGER
  systemStatusAnyErrorCondition INTEGER
  systemStatusAnyTestMode INTEGER
  systemStatusAnySparePart INTEGER
  systemStatusUsedNodeId Unsigned32
  systemStatusLocalRack Unsigned32
  systemStatusLocalSlot Unsigned32

ModuleInventoryEntry  
SEQUENCE    
  moduleInventoryIndex INTEGER
  moduleInventoryExpectedModule DisplayString
  moduleInventoryModule DisplayString
  moduleInventoryType INTEGER
  moduleInventoryBoardCode Integer32
  moduleInventoryAdditionalInfo DisplayString
  moduleInventorySerialNumber DisplayString
  moduleInventoryOccupiedSlots Unsigned32
  moduleInventoryProjectNumber DisplayString
  moduleInventoryBuildVersion DisplayString
  moduleInventoryProductionDate DisplayString
  moduleInventoryMfgTestInfo DisplayString
  moduleInventoryNumberOfOpticalPorts Integer32
  moduleInventoryNumberOfSfpPorts Integer32
  moduleInventoryNumberOfXfpPorts Integer32
  moduleInventoryCoreFirmwareVersion DisplayString
  moduleInventoryCoreFirmwareDate DisplayString
  moduleInventoryApplFirmwareVersion DisplayString
  moduleInventoryApplFirmwareDate DisplayString

ModuleStatusEntry  
SEQUENCE    
  moduleStatusIndex INTEGER
  moduleStatusModule DisplayString
  moduleStatusSystemOk INTEGER
  moduleStatusErrorCondition INTEGER
  moduleStatusTestMode INTEGER
  moduleStatusSparePart INTEGER
  moduleStatusUptime Counter32
  moduleStatusTimeSinceCounterReset Counter32
  moduleStatusTemperature Integer32
  moduleStatusTooHot INTEGER
  moduleStatusBackupState BITS
  moduleStatusBackupCounter Unsigned32
  moduleStatusBackupDuration Counter32

PortStatusEntry  
SEQUENCE    
  portStatusPortIndex INTEGER
  portStatusModule DisplayString
  portStatusLocation DisplayString
  portStatusSnmpPort Unsigned32
  portStatusAlias DisplayString
  portStatusAdminStatus INTEGER
  portStatusOperStatus INTEGER
  portStatusDetailedStatus BITS
  portStatusPortDatarate INTEGER
  portStatusUpdateTimeStamp DisplayString
  portStatusTimeSinceValueReset Counter32
  portStatusTimeSinceLastError Counter32
  portStatusTimeSignalTooLow Counter32
  portStatusSignalTooLowCounter Unsigned32
  portStatusTimeSignalTooHigh Counter32
  portStatusSignalTooHighCounter Unsigned32
  portStatusLowThreshold DisplayString
  portStatusCurrentInputSignal DisplayString
  portStatusHighThreshold DisplayString

EmStatusEntry  
SEQUENCE    
  emStatusIndex INTEGER
  emStatusSystemOk INTEGER
  emStatusErrors BITS
  emStatusHardwareCode DisplayString
  emStatusTimeSincePowerError Counter32
  emStatusTimeWithPowerLoss Counter32
  emStatusInputSignalLowCounter Unsigned32
  emStatusInputPower DisplayString
  emStatusSignalGain DisplayString
  emStatusOptimalFlatGain DisplayString
  emStatusBackReflection DisplayString
  emStatusSignalOutputPower DisplayString
  emStatusTotalOutputPower DisplayString
  emStatusMinOutputPower DisplayString
  emStatusMaxOutputPower DisplayString
  emStatusCfgOutputPower DisplayString

BertStatusEntry  
SEQUENCE    
  bertStatusIndex INTEGER
  bertStatusLocation DisplayString
  bertStatusBertOperation INTEGER
  bertStatusTotalErrors Unsigned32
  bertStatusTimeSinceLastError Counter32
  bertStatusTotalTestTime Counter32
  bertStatusErroredTime Counter32
  bertStatusBitErrorRate DisplayString
  bertStatusBerSinceLastError DisplayString
  bertStatusTheoreticalBer DisplayString
  bertStatusAvailability DisplayString

Defined Values

device 1.3.6.1.4.1.3181.10.6.1
Microsens private MIB for Generation 6 Ethernet Switches
MODULE-IDENTITY    

msp1000 1.3.6.1.4.1.3181.10.6.1.94
OBJECT IDENTIFIER    

systemConfigTable 1.3.6.1.4.1.3181.10.6.1.94.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SystemConfigEntry

systemConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.1.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SystemConfigEntry  

systemConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.1.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0  

systemConfigNmsOperationMode 1.3.6.1.4.1.3181.10.6.1.94.1.1.2
Read and learn in PASSIVE mode or ACTIVE mode forcing configuration upon the other modules.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER passive(0), active(1)  

systemConfigCoreMode 1.3.6.1.4.1.3181.10.6.1.94.1.1.3
Use V2 unless used with an older system running in V1 mode. Only change when instructed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER v1(0), v2(1)  

systemConfigNodeId 1.3.6.1.4.1.3181.10.6.1.94.1.1.4
Node Id used when NMS is used in combination with SEEmiles V5 management software. When in doubt use default node id 60000.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

systemConfigDisableLegacyAccess 1.3.6.1.4.1.3181.10.6.1.94.1.1.5
When set network access via SEEmiles is no longer possible.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

slotConfigTable 1.3.6.1.4.1.3181.10.6.1.94.2
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SlotConfigEntry

slotConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.2.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SlotConfigEntry  

slotConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.2.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..11  

slotConfigModule 1.3.6.1.4.1.3181.10.6.1.94.2.1.2
Defines which module is expected to be placed in this slot. This should be identical to the actual hardware. The value may be set prior to actual roll-out to preconfigure the system.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER undefined(0), empty(1), legacy(2), passive(3), x2g(61), txg(63), cxg(87), t4g(62), em2(105), em3(109), om1(104), lp1(106), os1(72), m2g(56), cxgp(88), nm1(65), nm2(66), nm3(108), nm3p(110), xcm1(60), tdm4(50), wcm2(57), fc8Filter(10), fc8aFilter(11), fc8xFilter(12), b4sFilter(13), b4xFilter(14), b8mFilter(15), b8dFilter(16), fd4Filter(17), dc1Filter(18), se1(19)  

slotConfigSparepartMode 1.3.6.1.4.1.3181.10.6.1.94.2.1.3
When enabled the module is operating normally but will not generate any alarms. This is useful for modules that are inserted but only used as spare and are not properly connected at this time. This way unnecassary alarms are avoided.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

slotConfigPort1Alias 1.3.6.1.4.1.3181.10.6.1.94.2.1.4
User defined port name for easier reference.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

slotConfigPort2Alias 1.3.6.1.4.1.3181.10.6.1.94.2.1.5
User defined port name for easier reference.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

slotConfigPort3Alias 1.3.6.1.4.1.3181.10.6.1.94.2.1.6
User defined port name for easier reference.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

slotConfigPort4Alias 1.3.6.1.4.1.3181.10.6.1.94.2.1.7
User defined port name for easier reference.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

x2gConfigTable 1.3.6.1.4.1.3181.10.6.1.94.3
This table is used to define any X2G or OFX-3 modules in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    X2gConfigEntry

x2gConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.3.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  X2gConfigEntry  

x2gConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.3.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..11  

x2gConfigPort1Datarate 1.3.6.1.4.1.3181.10.6.1.94.3.1.2
This parameter defines the data rate used to setup the internal retimer to provide 3R regeneration. Note that internally interconnected ports must be set to the same rate.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER transparent(0), ms100mEth(2), ms1gEth(8), ms1xFc(7), ms2xFc(10), oc3(3), oc12(6), oc48(11), otu1(13), fix100(1), escon(4), sdi(5), hdtv(9), m2g(12)  

x2gConfigPort2Datarate 1.3.6.1.4.1.3181.10.6.1.94.3.1.3
This parameter defines the data rate used to setup the internal retimer to provide 3R regeneration. Note that internally interconnected ports must be set to the same rate.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER transparent(0), ms100mEth(2), ms1gEth(8), ms1xFc(7), ms2xFc(10), oc3(3), oc12(6), oc48(11), otu1(13), fix100(1), escon(4), sdi(5), hdtv(9), m2g(12)  

x2gConfigPort3Datarate 1.3.6.1.4.1.3181.10.6.1.94.3.1.4
This parameter defines the data rate used to setup the internal retimer to provide 3R regeneration. Note that internally interconnected ports must be set to the same rate.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER transparent(0), ms100mEth(2), ms1gEth(8), ms1xFc(7), ms2xFc(10), oc3(3), oc12(6), oc48(11), otu1(13), fix100(1), escon(4), sdi(5), hdtv(9), m2g(12)  

x2gConfigPort4Datarate 1.3.6.1.4.1.3181.10.6.1.94.3.1.5
This parameter defines the data rate used to setup the internal retimer to provide 3R regeneration. Note that internally interconnected ports must be set to the same rate.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER transparent(0), ms100mEth(2), ms1gEth(8), ms1xFc(7), ms2xFc(10), oc3(3), oc12(6), oc48(11), otu1(13), fix100(1), escon(4), sdi(5), hdtv(9), m2g(12)  

x2gConfigCrossConnect 1.3.6.1.4.1.3181.10.6.1.94.3.1.6
This parameter defines the data path through the module. It is also used to setup a permanent bit error rate test.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disconnect(0), normal(20), alternate(1), backup(5), ringBackupWest(9), ringBackupEast(15), multicast(11), dropContinue(12), addDropWest(13), addDropEast(14), crossOver(16), switchP1P2(17), switchP1P3(18), switchP1P4(19), bertPort4(21)  

x2gConfigDeactivatePort1 1.3.6.1.4.1.3181.10.6.1.94.3.1.7
When enabled, the optical interface is disabled and communication is cut.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

x2gConfigDeactivatePort2 1.3.6.1.4.1.3181.10.6.1.94.3.1.8
When enabled, the optical interface is disabled and communication is cut.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

x2gConfigDeactivatePort3 1.3.6.1.4.1.3181.10.6.1.94.3.1.9
When enabled, the optical interface is disabled and communication is cut.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

x2gConfigDeactivatePort4 1.3.6.1.4.1.3181.10.6.1.94.3.1.10
When enabled, the optical interface is disabled and communication is cut.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

x2gConfigFrontPanelMode 1.3.6.1.4.1.3181.10.6.1.94.3.1.11
Determines what is displayed on the front panel, when available. Also controls the modules local buttons.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(0), extended(1), normalLocked(4), extendedLocked(5), remote(7)  

x2gConfigLossOfSignalHandling 1.3.6.1.4.1.3181.10.6.1.94.3.1.12
When set to LOCAL a loss of input signal will not affect another port. When set to PERCOLATE, a loss of signal will turn off the transmitter of the currently associated port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER local(0), percolate(1)  

x2gConfigOptimizedFor8b10b 1.3.6.1.4.1.3181.10.6.1.94.3.1.13
Enable this feature when Ethernet or FibreChannel is used. Do not set when SDH is used on any port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

x2gConfigBertPattern 1.3.6.1.4.1.3181.10.6.1.94.3.1.14
Defines the bit pattern with which the build-in bit error rate tester (BERT) operates when cross connect is set to BERT.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ms27(0), ms223(2), ms231(3), cjPat(4), crPat(5), ms8b10bCnt(6)  

x2gConfigSfpDeltaInterval 1.3.6.1.4.1.3181.10.6.1.94.3.1.15
This enables and defines the interval in which the optical receive power level of each SFP is read and compared to previous value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), ms1Sec(1), ms5Sec(2), ms10Sec(3), ms30Sec(4), ms60Sec(5), ms240Sec(6)  

x2gConfigSfpDeltaThreshold 1.3.6.1.4.1.3181.10.6.1.94.3.1.16
This defines how much the optical receive power level can differ between successive reads before a warning trap is generated.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ms05Db(0), ms1Db(1), ms15Db(2), ms2Db(3), ms3Db(4), ms5Db(5)  

x2gConfigBackupTrigger 1.3.6.1.4.1.3181.10.6.1.94.3.1.17
Defines under which optical signal condition an automated backup is initiated.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), signalLoss(1), clockLoss(2)  


x2gConfigBackupEnd 1.3.6.1.4.1.3181.10.6.1.94.3.1.19
Defines how long the signal must remain steady before proper operation is assumed and the backup is terminated.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noDelay(0), ms15Seconds(1), ms15Minutes(2), manually(3)  

x2gConfigPermitLinkOverride 1.3.6.1.4.1.3181.10.6.1.94.3.1.20
Permits the manual selection of a failed link using the link selection. Defaults to false to safeguard against accidential link selection which would result in loss of connection.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

txgConfigTable 1.3.6.1.4.1.3181.10.6.1.94.4
This table is used to define any TXG or XCM-2 modules in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TxgConfigEntry

txgConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.4.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  TxgConfigEntry  

txgConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.4.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..11  

txgConfigTxgDatarate 1.3.6.1.4.1.3181.10.6.1.94.4.1.2
This parameter defines the data rate used to setup the internal retimer to provide 3R regeneration. Note that internally interconnected ports must be set to the same rate.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER oc192(1), oc192Fec(3), ms10gEth(2), ms10xFc(5), otu2(4), otu1f(7), otu2e(6), otu2f(8)  

txgConfigTxgOperationMode 1.3.6.1.4.1.3181.10.6.1.94.4.1.3
This parameter defines the data path through the module when an internal cross connect is avalable. It is also used to setup a permanent bit error rate test. (most settings apply to X2G, TXG, OFX-3, XCM-2 only)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), transponder(2), repeater(3), bertPort1(4), bertPort2(5)  

txgConfigPort1ItuChannel 1.3.6.1.4.1.3181.10.6.1.94.4.1.4
Tunable laser are supported. Select the wavelength from the supplied 100GHZ ITU-T grid. If the wavelength is not supported by the XFP, a warning event will be received.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fixed(0), ch11(22), ch12(24), ch13(26), ch14(28), ch15(30), ch16(32), ch17(34), ch18(36), ch19(38), ch20(40), ch21(42), ch22(44), ch23(46), ch24(48), ch25(50), ch26(52), ch27(54), ch28(56), ch29(58), ch30(60), ch31(62), ch32(64), ch33(66), ch34(68), ch35(70), ch36(72), ch37(74), ch38(76), ch39(78), ch40(80), ch41(82), ch42(84), ch43(86), ch44(88), ch45(90), ch46(92), ch47(94), ch48(96), ch49(98), ch50(100), ch51(102), ch52(104), ch53(106), ch54(108), ch55(110), ch56(112), ch57(114), ch58(116), ch59(118), ch60(120), ch61(122), ch62(124), ch63(126)  

txgConfigPort2ItuChannel 1.3.6.1.4.1.3181.10.6.1.94.4.1.5
Tunable laser are supported. Select the wavelength from the supplied 100GHZ ITU-T grid. If the wavelength is not supported by the XFP, a warning event will be received.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fixed(0), ch11(22), ch12(24), ch13(26), ch14(28), ch15(30), ch16(32), ch17(34), ch18(36), ch19(38), ch20(40), ch21(42), ch22(44), ch23(46), ch24(48), ch25(50), ch26(52), ch27(54), ch28(56), ch29(58), ch30(60), ch31(62), ch32(64), ch33(66), ch34(68), ch35(70), ch36(72), ch37(74), ch38(76), ch39(78), ch40(80), ch41(82), ch42(84), ch43(86), ch44(88), ch45(90), ch46(92), ch47(94), ch48(96), ch49(98), ch50(100), ch51(102), ch52(104), ch53(106), ch54(108), ch55(110), ch56(112), ch57(114), ch58(116), ch59(118), ch60(120), ch61(122), ch62(124), ch63(126)  

txgConfigDeactivatePort1 1.3.6.1.4.1.3181.10.6.1.94.4.1.6
When enabled, the optical interface is disabled and communication is cut.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

txgConfigDeactivatePort2 1.3.6.1.4.1.3181.10.6.1.94.4.1.7
When enabled, the optical interface is disabled and communication is cut.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

txgConfigFrontPanelMode 1.3.6.1.4.1.3181.10.6.1.94.4.1.8
Determines what is displayed on the front panel, when available. Also controls the modules local buttons.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(0), extended(1), normalLocked(4), extendedLocked(5), remote(7)  

txgConfigLossOfSignalHandling 1.3.6.1.4.1.3181.10.6.1.94.4.1.9
When set to LOCAL a loss of input signal will not affect another port. When set to PERCOLATE, a loss of signal will turn off the transmitter of the other port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER local(0), percolate(1)  

txgConfigBertPattern 1.3.6.1.4.1.3181.10.6.1.94.4.1.10
Defines the bit pattern with which the build-in bit error rate tester (BERT) operates when cross connect is set to BERT.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ms27(0), ms223(2), ms231(3), cjPat(4), crPat(5), ms8b10bCnt(6)  

txgConfigSfpDeltaInterval 1.3.6.1.4.1.3181.10.6.1.94.4.1.11
This enables and defines the interval in which the optical receive power level of each SFP/XFP is read and compared to previous value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), ms1Sec(1), ms5Sec(2), ms10Sec(3), ms30Sec(4), ms60Sec(5), ms240Sec(6)  

txgConfigSfpDeltaThreshold 1.3.6.1.4.1.3181.10.6.1.94.4.1.12
This defines how much the optical receive power level can differ between successive reads before a warning trap is generated.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ms05Db(0), ms1Db(1), ms15Db(2), ms2Db(3), ms3Db(4), ms5Db(5)  

cxgPlusConfigTable 1.3.6.1.4.1.3181.10.6.1.94.5
This table is used to define any CXG+ or OFC-10 modules in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CxgPlusConfigEntry

cxgPlusConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.5.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  CxgPlusConfigEntry  

cxgPlusConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.5.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..11  

cxgPlusConfigCxgPort12Datarate 1.3.6.1.4.1.3181.10.6.1.94.5.1.2
The CXG relies on the features of the XFP to define its datarate. Since various XFP offer different rates with the same settings, only a general setting is provided. Both ports must operate at the same rate.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER transparent(0), ms8xFc(1), ms10gEth(2), ms10xFc16xFc(3)  

cxgPlusConfigCxgPort34Datarate 1.3.6.1.4.1.3181.10.6.1.94.5.1.3
The CXG relies on the features of the XFP to define its datarate. Since various XFP offer different rates with the same settings, only a general setting is provided. Both ports must operate at the same rate.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER transparent(0), ms8xFc(1), ms10gEth(2), ms10xFc16xFc(3)  

cxgPlusConfigPort1ItuChannel 1.3.6.1.4.1.3181.10.6.1.94.5.1.4
Tunable laser are supported. Select the wavelength from the supplied 100GHZ ITU-T grid. If the wavelength is not supported by the XFP, a warning event will be received.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fixed(0), ch11(22), ch12(24), ch13(26), ch14(28), ch15(30), ch16(32), ch17(34), ch18(36), ch19(38), ch20(40), ch21(42), ch22(44), ch23(46), ch24(48), ch25(50), ch26(52), ch27(54), ch28(56), ch29(58), ch30(60), ch31(62), ch32(64), ch33(66), ch34(68), ch35(70), ch36(72), ch37(74), ch38(76), ch39(78), ch40(80), ch41(82), ch42(84), ch43(86), ch44(88), ch45(90), ch46(92), ch47(94), ch48(96), ch49(98), ch50(100), ch51(102), ch52(104), ch53(106), ch54(108), ch55(110), ch56(112), ch57(114), ch58(116), ch59(118), ch60(120), ch61(122), ch62(124), ch63(126)  

cxgPlusConfigPort2ItuChannel 1.3.6.1.4.1.3181.10.6.1.94.5.1.5
Tunable laser are supported. Select the wavelength from the supplied 100GHZ ITU-T grid. If the wavelength is not supported by the XFP, a warning event will be received.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fixed(0), ch11(22), ch12(24), ch13(26), ch14(28), ch15(30), ch16(32), ch17(34), ch18(36), ch19(38), ch20(40), ch21(42), ch22(44), ch23(46), ch24(48), ch25(50), ch26(52), ch27(54), ch28(56), ch29(58), ch30(60), ch31(62), ch32(64), ch33(66), ch34(68), ch35(70), ch36(72), ch37(74), ch38(76), ch39(78), ch40(80), ch41(82), ch42(84), ch43(86), ch44(88), ch45(90), ch46(92), ch47(94), ch48(96), ch49(98), ch50(100), ch51(102), ch52(104), ch53(106), ch54(108), ch55(110), ch56(112), ch57(114), ch58(116), ch59(118), ch60(120), ch61(122), ch62(124), ch63(126)  

cxgPlusConfigPort3ItuChannel 1.3.6.1.4.1.3181.10.6.1.94.5.1.6
Tunable laser are supported. Select the wavelength from the supplied 100GHZ ITU-T grid. If the wavelength is not supported by the XFP, a warning event will be received.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fixed(0), ch11(22), ch12(24), ch13(26), ch14(28), ch15(30), ch16(32), ch17(34), ch18(36), ch19(38), ch20(40), ch21(42), ch22(44), ch23(46), ch24(48), ch25(50), ch26(52), ch27(54), ch28(56), ch29(58), ch30(60), ch31(62), ch32(64), ch33(66), ch34(68), ch35(70), ch36(72), ch37(74), ch38(76), ch39(78), ch40(80), ch41(82), ch42(84), ch43(86), ch44(88), ch45(90), ch46(92), ch47(94), ch48(96), ch49(98), ch50(100), ch51(102), ch52(104), ch53(106), ch54(108), ch55(110), ch56(112), ch57(114), ch58(116), ch59(118), ch60(120), ch61(122), ch62(124), ch63(126)  

cxgPlusConfigPort4ItuChannel 1.3.6.1.4.1.3181.10.6.1.94.5.1.7
Tunable laser are supported. Select the wavelength from the supplied 100GHZ ITU-T grid. If the wavelength is not supported by the XFP, a warning event will be received.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fixed(0), ch11(22), ch12(24), ch13(26), ch14(28), ch15(30), ch16(32), ch17(34), ch18(36), ch19(38), ch20(40), ch21(42), ch22(44), ch23(46), ch24(48), ch25(50), ch26(52), ch27(54), ch28(56), ch29(58), ch30(60), ch31(62), ch32(64), ch33(66), ch34(68), ch35(70), ch36(72), ch37(74), ch38(76), ch39(78), ch40(80), ch41(82), ch42(84), ch43(86), ch44(88), ch45(90), ch46(92), ch47(94), ch48(96), ch49(98), ch50(100), ch51(102), ch52(104), ch53(106), ch54(108), ch55(110), ch56(112), ch57(114), ch58(116), ch59(118), ch60(120), ch61(122), ch62(124), ch63(126)  

cxgPlusConfigDeactivatePort1 1.3.6.1.4.1.3181.10.6.1.94.5.1.8
When enabled, the optical interface is disabled and communication is cut.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

cxgPlusConfigDeactivatePort2 1.3.6.1.4.1.3181.10.6.1.94.5.1.9
When enabled, the optical interface is disabled and communication is cut.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

cxgPlusConfigDeactivatePort3 1.3.6.1.4.1.3181.10.6.1.94.5.1.10
When enabled, the optical interface is disabled and communication is cut.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

cxgPlusConfigDeactivatePort4 1.3.6.1.4.1.3181.10.6.1.94.5.1.11
When enabled, the optical interface is disabled and communication is cut.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

cxgPlusConfigFrontPanelMode 1.3.6.1.4.1.3181.10.6.1.94.5.1.12
Determines what is displayed on the front panel, when available. Also controls the modules local buttons.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(0), extended(1), normalLocked(4), extendedLocked(5), remote(7)  

cxgPlusConfigLossOfSignalHandling 1.3.6.1.4.1.3181.10.6.1.94.5.1.13
When set to LOCAL a loss of input signal will not affect another port. When set to PERCOLATE, a loss of signal will turn off the transmitter of the other port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER local(0), percolate(1)  

cxgPlusConfigSfpDeltaInterval 1.3.6.1.4.1.3181.10.6.1.94.5.1.14
This enables and defines the interval in which the optical receive power level of each SFP/XFP is read and compared to previous value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), ms1Sec(1), ms5Sec(2), ms10Sec(3), ms30Sec(4), ms60Sec(5), ms240Sec(6)  

cxgPlusConfigSfpDeltaThreshold 1.3.6.1.4.1.3181.10.6.1.94.5.1.15
This defines how much the optical receive power level can differ between successive reads before a warning trap is generated.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ms05Db(0), ms1Db(1), ms15Db(2), ms2Db(3), ms3Db(4), ms5Db(5)  

cxgConfigTable 1.3.6.1.4.1.3181.10.6.1.94.6
This table is used to define any CXG or XCM-3 modules in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CxgConfigEntry

cxgConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.6.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  CxgConfigEntry  

cxgConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.6.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..11  

cxgConfigCxgPort12Datarate 1.3.6.1.4.1.3181.10.6.1.94.6.1.2
The CXG relies on the features of the XFP to define its datarate. Since various XFP offer different rates with the same settings, only a general setting is provided. Both ports must operate at the same rate.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER transparent(0), ms8xFc(1), ms10gEth(2), ms10xFc16xFc(3)  

cxgConfigPort1ItuChannel 1.3.6.1.4.1.3181.10.6.1.94.6.1.3
Tunable laser are supported. Select the wavelength from the supplied 100GHZ ITU-T grid. If the wavelength is not supported by the XFP, a warning event will be received.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fixed(0), ch11(22), ch12(24), ch13(26), ch14(28), ch15(30), ch16(32), ch17(34), ch18(36), ch19(38), ch20(40), ch21(42), ch22(44), ch23(46), ch24(48), ch25(50), ch26(52), ch27(54), ch28(56), ch29(58), ch30(60), ch31(62), ch32(64), ch33(66), ch34(68), ch35(70), ch36(72), ch37(74), ch38(76), ch39(78), ch40(80), ch41(82), ch42(84), ch43(86), ch44(88), ch45(90), ch46(92), ch47(94), ch48(96), ch49(98), ch50(100), ch51(102), ch52(104), ch53(106), ch54(108), ch55(110), ch56(112), ch57(114), ch58(116), ch59(118), ch60(120), ch61(122), ch62(124), ch63(126)  

cxgConfigPort2ItuChannel 1.3.6.1.4.1.3181.10.6.1.94.6.1.4
Tunable laser are supported. Select the wavelength from the supplied 100GHZ ITU-T grid. If the wavelength is not supported by the XFP, a warning event will be received.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fixed(0), ch11(22), ch12(24), ch13(26), ch14(28), ch15(30), ch16(32), ch17(34), ch18(36), ch19(38), ch20(40), ch21(42), ch22(44), ch23(46), ch24(48), ch25(50), ch26(52), ch27(54), ch28(56), ch29(58), ch30(60), ch31(62), ch32(64), ch33(66), ch34(68), ch35(70), ch36(72), ch37(74), ch38(76), ch39(78), ch40(80), ch41(82), ch42(84), ch43(86), ch44(88), ch45(90), ch46(92), ch47(94), ch48(96), ch49(98), ch50(100), ch51(102), ch52(104), ch53(106), ch54(108), ch55(110), ch56(112), ch57(114), ch58(116), ch59(118), ch60(120), ch61(122), ch62(124), ch63(126)  

cxgConfigDeactivatePort1 1.3.6.1.4.1.3181.10.6.1.94.6.1.5
When enabled, the optical interface is disabled and communication is cut.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

cxgConfigDeactivatePort2 1.3.6.1.4.1.3181.10.6.1.94.6.1.6
When enabled, the optical interface is disabled and communication is cut.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

cxgConfigFrontPanelMode 1.3.6.1.4.1.3181.10.6.1.94.6.1.7
Determines what is displayed on the front panel, when available. Also controls the modules local buttons.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(0), extended(1), normalLocked(4), extendedLocked(5), remote(7)  

cxgConfigLossOfSignalHandling 1.3.6.1.4.1.3181.10.6.1.94.6.1.8
When set to LOCAL a loss of input signal will not affect another port. When set to PERCOLATE, a loss of signal will turn off the transmitter of the other port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER local(0), percolate(1)  

cxgConfigSfpDeltaInterval 1.3.6.1.4.1.3181.10.6.1.94.6.1.9
This enables and defines the interval in which the optical receive power level of each SFP/XFP is read and compared to previous value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), ms1Sec(1), ms5Sec(2), ms10Sec(3), ms30Sec(4), ms60Sec(5), ms240Sec(6)  

cxgConfigSfpDeltaThreshold 1.3.6.1.4.1.3181.10.6.1.94.6.1.10
This defines how much the optical receive power level can differ between successive reads before a warning trap is generated.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ms05Db(0), ms1Db(1), ms15Db(2), ms2Db(3), ms3Db(4), ms5Db(5)  

t4gConfigTable 1.3.6.1.4.1.3181.10.6.1.94.7
This table is used to define any T4G or OFC-4 modules in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    T4gConfigEntry

t4gConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.7.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  T4gConfigEntry  

t4gConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.7.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..11  

t4gConfigT4gPort12Datarate 1.3.6.1.4.1.3181.10.6.1.94.7.1.2
The CXG relies on the features of the XFP to define its datarate. Since various XFP offer different rates with the same settings, only a general setting is provided. Both ports must operate at the same rate.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER transparent(0), ms100mEth(2), ms1gEth(8), escon(4), ms1xFc(7), ms2xFc(10), ms4xFc(14), infiniband(12), oc3(3), oc12(6), oc48(11)  

t4gConfigT4gPort34Datarate 1.3.6.1.4.1.3181.10.6.1.94.7.1.3
Tunable laser are supported. Select the wavelength from the supplied 100GHZ ITU-T grid. If the wavelength is not supported by the XFP, a warning event will be received.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER transparent(0), ms100mEth(2), ms1gEth(8), escon(4), ms1xFc(7), ms2xFc(10), ms4xFc(14), infiniband(12), oc3(3), oc12(6), oc48(11)  

t4gConfigT4gOperationMode 1.3.6.1.4.1.3181.10.6.1.94.7.1.4
This parameter defines the data path through the module when an internal cross connect is avalable. It is also used to setup a permanent bit error rate test. (most settings apply to X2G, TXG, OFX-3, XCM-2 only)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), transponder(1), bertPort4(2)  

t4gConfigDeactivatePort1 1.3.6.1.4.1.3181.10.6.1.94.7.1.5
When enabled, the optical interface is disabled and communication is cut.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

t4gConfigDeactivatePort2 1.3.6.1.4.1.3181.10.6.1.94.7.1.6
When enabled, the optical interface is disabled and communication is cut.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

t4gConfigDeactivatePort3 1.3.6.1.4.1.3181.10.6.1.94.7.1.7
When enabled, the optical interface is disabled and communication is cut.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

t4gConfigDeactivatePort4 1.3.6.1.4.1.3181.10.6.1.94.7.1.8
When enabled, the optical interface is disabled and communication is cut.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

t4gConfigFrontPanelMode 1.3.6.1.4.1.3181.10.6.1.94.7.1.9
Determines what is displayed on the front panel, when available. Also controls the modules local buttons.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(0), extended(1), normalLocked(4), extendedLocked(5), remote(7)  

t4gConfigLossOfSignalHandling 1.3.6.1.4.1.3181.10.6.1.94.7.1.10
When set to LOCAL a loss of input signal will not affect another port. When set to PERCOLATE, a loss of signal will turn off the transmitter of the other port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER local(0), percolate(1)  

t4gConfigBertPattern 1.3.6.1.4.1.3181.10.6.1.94.7.1.11
Defines the bit pattern with which the build-in bit error rate tester (BERT) operates when cross connect is set to BERT.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ms27(0), ms223(2), ms231(3), cjPat(4), crPat(5), ms8b10bCnt(6)  

t4gConfigSfpDeltaInterval 1.3.6.1.4.1.3181.10.6.1.94.7.1.12
This enables and defines the interval in which the optical receive power level of each SFP/XFP is read and compared to previous value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), ms1Sec(1), ms5Sec(2), ms10Sec(3), ms30Sec(4), ms60Sec(5), ms240Sec(6)  

t4gConfigSfpDeltaThreshold 1.3.6.1.4.1.3181.10.6.1.94.7.1.13
This defines how much the optical receive power level can differ between successive reads before a warning trap is generated.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ms05Db(0), ms1Db(1), ms15Db(2), ms2Db(3), ms3Db(4), ms5Db(5)  

m2gConfigTable 1.3.6.1.4.1.3181.10.6.1.94.8
This table is used to define any M2G or TDM-2 modules in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    M2gConfigEntry

m2gConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.8.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  M2gConfigEntry  

m2gConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.8.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..11  

m2gConfigChannel1Datarate 1.3.6.1.4.1.3181.10.6.1.94.8.1.2
Devices the datarate of the first TDM channel (port 1)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), ms1gEth(1), ms1xFc(2)  

m2gConfigChannel2Datarate 1.3.6.1.4.1.3181.10.6.1.94.8.1.3
Devices the datarate of the second TDM channel (port 2)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), ms1gEth(1), ms1xFc(2)  

m2gConfigPort1CopperSfp 1.3.6.1.4.1.3181.10.6.1.94.8.1.4
Set when local copper RJ45 SFP is used and connection cannot be established.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

m2gConfigPort2CopperSfp 1.3.6.1.4.1.3181.10.6.1.94.8.1.5
Set when local copper RJ45 SFP is used and connection cannot be established.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

m2gConfigSfpDeltaInterval 1.3.6.1.4.1.3181.10.6.1.94.8.1.6
This enables and defines the interval in which the optical receive power level of each SFP/XFP is read and compared to previous value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), ms1Sec(1), ms5Sec(2), ms10Sec(3), ms30Sec(4), ms60Sec(5), ms240Sec(6)  

m2gConfigSfpDeltaThreshold 1.3.6.1.4.1.3181.10.6.1.94.8.1.7
This defines how much the optical receive power level can differ between successive reads before a warning trap is generated.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ms05Db(0), ms1Db(1), ms15Db(2), ms2Db(3), ms3Db(4), ms5Db(5)  

m2gConfigLinkBackupTrigger 1.3.6.1.4.1.3181.10.6.1.94.8.1.8
Defines under which optical signal condition an automated backup is initiated.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), signalLoss(1), errorBurst(2)  


m2gConfigBackupEnd 1.3.6.1.4.1.3181.10.6.1.94.8.1.10
Defines how long the signal must remain steady before proper operation is assumed and the backup is terminated.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noDelay(0), ms15Seconds(1), ms15Minutes(2), manually(3)  

m2gConfigPermitLinkOverride 1.3.6.1.4.1.3181.10.6.1.94.8.1.11
Permits the manual selection of a failed link using the link selection. Defaults to false to safeguard against accidential link selection which would result in loss of connection.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

om1ConfigTable 1.3.6.1.4.1.3181.10.6.1.94.9
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Om1ConfigEntry

om1ConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.9.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  Om1ConfigEntry  

om1ConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.9.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..11  

om1ConfigWavelengthPortA 1.3.6.1.4.1.3181.10.6.1.94.9.1.2
Defines which wavelength band is measured. Use 1550 setting when a WDM link is measured.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ms1550nm(0), ms1310nm(1), disabled(3)  

om1ConfigLowThresholdPortA 1.3.6.1.4.1.3181.10.6.1.94.9.1.3
Defines the lower optical signal level in dBm. A signal level below this threshold will trigger an event.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

om1ConfigHighThresholdPortA 1.3.6.1.4.1.3181.10.6.1.94.9.1.4
Defines the upper optical signal level in dBm. A signal level above this threshold will trigger an event.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

om1ConfigWavelengthPortB 1.3.6.1.4.1.3181.10.6.1.94.9.1.5
Defines which wavelength band is measured. Use 1550 setting when a WDM link is measured.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ms1550nm(0), ms1310nm(1), disabled(3)  

om1ConfigLowThresholdPortB 1.3.6.1.4.1.3181.10.6.1.94.9.1.6
Defines the lower optical signal level in dBm. A signal level below this threshold will trigger an event.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

om1ConfigHighThresholdPortB 1.3.6.1.4.1.3181.10.6.1.94.9.1.7
Defines the upper optical signal level in dBm. A signal level above this threshold will trigger an event.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

om1ConfigFrontPanelMode 1.3.6.1.4.1.3181.10.6.1.94.9.1.8
Determines what is displayed on the front panel, when available. Also controls the modules local buttons.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(0), extended(1), normalLocked(4), extendedLocked(5), remote(7)  

lp1ConfigTable 1.3.6.1.4.1.3181.10.6.1.94.10
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Lp1ConfigEntry

lp1ConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.10.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  Lp1ConfigEntry  

lp1ConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.10.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..11  

lp1ConfigWavelengthPortA 1.3.6.1.4.1.3181.10.6.1.94.10.1.2
Defines which wavelength band is measured. Use 1550 setting when a WDM link is measured.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ms1550nm(0), ms1310nm(1), disabled(3)  

lp1ConfigLowThresholdPortA 1.3.6.1.4.1.3181.10.6.1.94.10.1.3
Defines the lower optical signal level in dBm. A signal level below this threshold will trigger an event and a backup when configured.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

lp1ConfigHighThresholdPortA 1.3.6.1.4.1.3181.10.6.1.94.10.1.4
Defines the upper optical signal level in dBm. A signal level above this threshold will trigger an event and a backup when configured.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

lp1ConfigWavelengthPortB 1.3.6.1.4.1.3181.10.6.1.94.10.1.5
Defines which wavelength band is measured. Use 1550 setting when a WDM link is measured.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ms1550nm(0), ms1310nm(1), disabled(3)  

lp1ConfigLowThresholdPortB 1.3.6.1.4.1.3181.10.6.1.94.10.1.6
Defines the lower optical signal level in dBm. A signal level below this threshold will trigger an event and a backup when configured.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

lp1ConfigHighThresholdPortB 1.3.6.1.4.1.3181.10.6.1.94.10.1.7
Defines the upper optical signal level in dBm. A signal level above this threshold will trigger an event and a backup when configured.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

lp1ConfigBackupCriteria 1.3.6.1.4.1.3181.10.6.1.94.10.1.8
Defines under which optical signal condition an automated backup is initiated.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER signalLow(0), signalHigh(1), manually(2)  


lp1ConfigBackupEnd 1.3.6.1.4.1.3181.10.6.1.94.10.1.10
Defines how long the signal must remain steady before proper operation is assumed and the backup is terminated.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noDelay(0), ms15Seconds(1), ms15Minutes(2), manually(3)  

lp1ConfigFrontPanelMode 1.3.6.1.4.1.3181.10.6.1.94.10.1.11
Determines what is displayed on the front panel, when available. Also controls the modules local buttons.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(0), extended(1), normalLocked(4), extendedLocked(5), remote(7)  

emConfigTable 1.3.6.1.4.1.3181.10.6.1.94.11
Configuration for EDFA amplifier modules EM2 and EM3.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EmConfigEntry

emConfigEntry 1.3.6.1.4.1.3181.10.6.1.94.11.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  EmConfigEntry  

emConfigIndex 1.3.6.1.4.1.3181.10.6.1.94.11.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..11  

emConfigEdfaOperationMode 1.3.6.1.4.1.3181.10.6.1.94.11.1.2
Defines which wavelength band is measured. Use 1550 setting when a WDM link is measured.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER pumpDisabled(3), preAmp(0), booster(1)  

emConfigLossOfSignalHandling 1.3.6.1.4.1.3181.10.6.1.94.11.1.3
Defines if loss of input signal turns off the EDFA pump (PERCOLATE) or not (LOCAL)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER local(0), percolate(1)  

emConfigSignalGain 1.3.6.1.4.1.3181.10.6.1.94.11.1.4
Desired signal gain in dB.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

emConfigMaxOutputPower 1.3.6.1.4.1.3181.10.6.1.94.11.1.5
Maximum output power permitted to exit the module.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

emConfigLowThresholdEdfaIn 1.3.6.1.4.1.3181.10.6.1.94.11.1.6
This corresponds to the unamplified input signal before entering the EDFA section. Defines the lower optical signal level in dBm. A signal level below this threshold will trigger an event.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

emConfigHighThresholdEdfaIn 1.3.6.1.4.1.3181.10.6.1.94.11.1.7
This corresponds to the unamplified input signal before entering the EDFA section. Defines the upper optical signal level in dBm. A signal level above this threshold will trigger an event.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

emConfigLowThresholdPortB 1.3.6.1.4.1.3181.10.6.1.94.11.1.8
Port B is the unamplified return path through the module. Defines the lower optical signal level in dBm. A signal level below this threshold will trigger an event.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

emConfigHighThresholdPortB 1.3.6.1.4.1.3181.10.6.1.94.11.1.9
Port B is the unamplified return path through the module. Defines the upper optical signal level in dBm. A signal level above this threshold will trigger an event.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

emConfigFrontPanelMode 1.3.6.1.4.1.3181.10.6.1.94.11.1.10
Determines what is displayed on the front panel, when available. Also controls the modules local buttons.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(0), extended(1), normalLocked(4), extendedLocked(5), remote(7)  

moduleControlTable 1.3.6.1.4.1.3181.10.6.1.94.12
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ModuleControlEntry

moduleControlEntry 1.3.6.1.4.1.3181.10.6.1.94.12.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  ModuleControlEntry  

moduleControlIndex 1.3.6.1.4.1.3181.10.6.1.94.12.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..11  

moduleControlEnterPassword 1.3.6.1.4.1.3181.10.6.1.94.12.1.2
This command will set the module password. Only required when the nms_operation_mode is set to passive mode. Enter the password before configuration or actions can be accepted by the module.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

moduleControlRebootModule 1.3.6.1.4.1.3181.10.6.1.94.12.1.3
This command will restart the module. All communication will be disrupted! Syntax: reboot_module = CONFIRM.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

moduleControlWarmStart 1.3.6.1.4.1.3181.10.6.1.94.12.1.4
This command will warm start the module. Communication shall not be disrupted. (Firmware dependend) Syntax: warm_start = CONFIRM.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

moduleControlClearCounter 1.3.6.1.4.1.3181.10.6.1.94.12.1.5
This command will clear all module and port related statistics counter.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

moduleControlSwitchOffBackup 1.3.6.1.4.1.3181.10.6.1.94.12.1.6
For a module that supports backup and which currently is in backup condition this command will revert to normal operation. If this would disrupt traffic a warning is returned and nothing is executed. To override this warning and switch back nonetheless type switch_off_backup = CONFIRM
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

moduleControlSwitchToBackup 1.3.6.1.4.1.3181.10.6.1.94.12.1.7
For a module that supports backup this command will switch to the backup link. If this would disrupt traffic because backup link is not available a warning is returned and nothing is executed. To override this warning and switch over nonetheless type switch_to_backup = CONFIRM
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

moduleControlAutomaticBackup 1.3.6.1.4.1.3181.10.6.1.94.12.1.8
This command returns a manually overridden backup module to normal automatic mode. No parameter are required.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

moduleControlWriteDisplay 1.3.6.1.4.1.3181.10.6.1.94.12.1.9
Writes to the front panel display of the module. Only for modules that offer a front panel display.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

moduleControlLedTest 1.3.6.1.4.1.3181.10.6.1.94.12.1.10
This will start the modules LED test and will return the LED back up automatic mode after a few seconds. May be also be used to identify a certain module.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

moduleControlLoopOff 1.3.6.1.4.1.3181.10.6.1.94.12.1.11
Turns all loops off
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

moduleControlLoopPort1 1.3.6.1.4.1.3181.10.6.1.94.12.1.12
Tries to engage a loop at port 1. Note not all modules support loops. View port status to check success.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

moduleControlLoopPort2 1.3.6.1.4.1.3181.10.6.1.94.12.1.13
Tries to engage a loop at port 2. Note not all modules support loops. View port status to check success.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

moduleControlLoopPort3 1.3.6.1.4.1.3181.10.6.1.94.12.1.14
Tries to engage a loop at port 3. Note not all modules support loops. View port status to check success.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

moduleControlLoopPort4 1.3.6.1.4.1.3181.10.6.1.94.12.1.15
Tries to engage a loop at port 4. Note not all modules support loops. View port status to check success.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

moduleControlBertRestart 1.3.6.1.4.1.3181.10.6.1.94.12.1.16
Resynchronizes BERT. Only has an effect if a BERT is available on the module and configured to be active.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

moduleControlBertInsertError 1.3.6.1.4.1.3181.10.6.1.94.12.1.17
Inserts an error in the data pattern. This can be used to confirm that a BERT is actually operating. Only has an effect if a BERT is available on the module and configured to be active.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

moduleControlBertClearCounter 1.3.6.1.4.1.3181.10.6.1.94.12.1.18
Clears the BERT counter. Only has an effect if a BERT is available on the module and configured to be active.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

systemStatusTable 1.3.6.1.4.1.3181.10.6.1.94.100
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SystemStatusEntry

systemStatusEntry 1.3.6.1.4.1.3181.10.6.1.94.100.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SystemStatusEntry  

systemStatusIndex 1.3.6.1.4.1.3181.10.6.1.94.100.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0  

systemStatusAnyErrorCondition 1.3.6.1.4.1.3181.10.6.1.94.100.1.2
True when any error condition is currently present in any module.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

systemStatusAnyTestMode 1.3.6.1.4.1.3181.10.6.1.94.100.1.3
True when any module is in loopback test or has a backup engaged.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

systemStatusAnySparePart 1.3.6.1.4.1.3181.10.6.1.94.100.1.4
True when any module is marked as spare part.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

systemStatusUsedNodeId 1.3.6.1.4.1.3181.10.6.1.94.100.1.5
Actually used node id as discovered from device
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

systemStatusLocalRack 1.3.6.1.4.1.3181.10.6.1.94.100.1.6
Indicates in which rack the mangement module over which this information is retrieved is inserted.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

systemStatusLocalSlot 1.3.6.1.4.1.3181.10.6.1.94.100.1.7
Indicates in which slot the mangement module over which this information is retrieved is inserted.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

moduleInventoryTable 1.3.6.1.4.1.3181.10.6.1.94.101
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ModuleInventoryEntry

moduleInventoryEntry 1.3.6.1.4.1.3181.10.6.1.94.101.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  ModuleInventoryEntry  

moduleInventoryIndex 1.3.6.1.4.1.3181.10.6.1.94.101.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..11  

moduleInventoryExpectedModule 1.3.6.1.4.1.3181.10.6.1.94.101.1.2
Name of module configured for this slot.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

moduleInventoryModule 1.3.6.1.4.1.3181.10.6.1.94.101.1.3
Name of module actually discovered in this slot. This name should be equal to the above name otherwise configuration may not apply properly.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

moduleInventoryType 1.3.6.1.4.1.3181.10.6.1.94.101.1.4
General functional type of module inserted.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER empty(0), unknown(1), transponder(2), measurement(3), amplifier(4), management(5), passive(6), occupied(7)  

moduleInventoryBoardCode 1.3.6.1.4.1.3181.10.6.1.94.101.1.5
Internal code of actually inserted module.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

moduleInventoryAdditionalInfo 1.3.6.1.4.1.3181.10.6.1.94.101.1.6
Additional information that may be saved in some modules during production.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

moduleInventorySerialNumber 1.3.6.1.4.1.3181.10.6.1.94.101.1.7
Serial number as stored within the hardware.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

moduleInventoryOccupiedSlots 1.3.6.1.4.1.3181.10.6.1.94.101.1.8
Number of slots taken by this module. Usually 1.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

moduleInventoryProjectNumber 1.3.6.1.4.1.3181.10.6.1.94.101.1.9
Internal hardware project number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

moduleInventoryBuildVersion 1.3.6.1.4.1.3181.10.6.1.94.101.1.10
Precise build code for hardware version tracking.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

moduleInventoryProductionDate 1.3.6.1.4.1.3181.10.6.1.94.101.1.11
Production data of the module
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

moduleInventoryMfgTestInfo 1.3.6.1.4.1.3181.10.6.1.94.101.1.12
Internal information for quality management. Manufacturing Site / Test Site / Test Person
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

moduleInventoryNumberOfOpticalPorts 1.3.6.1.4.1.3181.10.6.1.94.101.1.13
Indicates the number of actively monitored optical ports of this type of module.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

moduleInventoryNumberOfSfpPorts 1.3.6.1.4.1.3181.10.6.1.94.101.1.14
Indicates the number of optical SFP or SFP+ ports of this type of module.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

moduleInventoryNumberOfXfpPorts 1.3.6.1.4.1.3181.10.6.1.94.101.1.15
Indicates the number of optical XFP ports of this type of module.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

moduleInventoryCoreFirmwareVersion 1.3.6.1.4.1.3181.10.6.1.94.101.1.16
Core operating system software version.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

moduleInventoryCoreFirmwareDate 1.3.6.1.4.1.3181.10.6.1.94.101.1.17
Core operating system software creation date.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

moduleInventoryApplFirmwareVersion 1.3.6.1.4.1.3181.10.6.1.94.101.1.18
Application software version.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

moduleInventoryApplFirmwareDate 1.3.6.1.4.1.3181.10.6.1.94.101.1.19
Application software creation date.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

moduleStatusTable 1.3.6.1.4.1.3181.10.6.1.94.102
This table holds a record for each module in the system. Note that not all modules deliver every kind of status.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ModuleStatusEntry

moduleStatusEntry 1.3.6.1.4.1.3181.10.6.1.94.102.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  ModuleStatusEntry  

moduleStatusIndex 1.3.6.1.4.1.3181.10.6.1.94.102.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..11  

moduleStatusModule 1.3.6.1.4.1.3181.10.6.1.94.102.1.2
Name of module actually discovered in this slot.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

moduleStatusSystemOk 1.3.6.1.4.1.3181.10.6.1.94.102.1.3
True when the module has booted and appears ok.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

moduleStatusErrorCondition 1.3.6.1.4.1.3181.10.6.1.94.102.1.4
True when any error condition is currently present.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

moduleStatusTestMode 1.3.6.1.4.1.3181.10.6.1.94.102.1.5
True when module is in loopback test or a backup is engaged.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

moduleStatusSparePart 1.3.6.1.4.1.3181.10.6.1.94.102.1.6
True when module is marked as spare part.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

moduleStatusUptime 1.3.6.1.4.1.3181.10.6.1.94.102.1.7
Uptime since last reboot in seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

moduleStatusTimeSinceCounterReset 1.3.6.1.4.1.3181.10.6.1.94.102.1.8
How long ago have the statistics counter been restarted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

moduleStatusTemperature 1.3.6.1.4.1.3181.10.6.1.94.102.1.9
Temperature value in centigrade.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

moduleStatusTooHot 1.3.6.1.4.1.3181.10.6.1.94.102.1.10
True when module is running too hot.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

moduleStatusBackupState 1.3.6.1.4.1.3181.10.6.1.94.102.1.11
Indicates if a backup is active and in which state.
Status: current Access: read-only
OBJECT-TYPE    
  BITS disrupted(0), backup(1), awaitSwitchback(2), manual(3)  

moduleStatusBackupCounter 1.3.6.1.4.1.3181.10.6.1.94.102.1.12
Counts the number of times this module has initiated a backup (if backup feature is available for this module type).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

moduleStatusBackupDuration 1.3.6.1.4.1.3181.10.6.1.94.102.1.13
How long the backup has been activated in total since last value reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

portStatusTable 1.3.6.1.4.1.3181.10.6.1.94.103
This table holds a record for each optical port of the system. Note that not all modules deliver every kind of statistic.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PortStatusEntry

portStatusEntry 1.3.6.1.4.1.3181.10.6.1.94.103.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  PortStatusEntry  

portStatusPortIndex 1.3.6.1.4.1.3181.10.6.1.94.103.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..47  

portStatusModule 1.3.6.1.4.1.3181.10.6.1.94.103.1.2
Name of module in which this port is present.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

portStatusLocation 1.3.6.1.4.1.3181.10.6.1.94.103.1.3
Textual description of port location.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

portStatusSnmpPort 1.3.6.1.4.1.3181.10.6.1.94.103.1.4
Slot and port representation as used in SNMP. Formula is Slot*10000 + Port*10.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

portStatusAlias 1.3.6.1.4.1.3181.10.6.1.94.103.1.5
Configured alias nickname of this port.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

portStatusAdminStatus 1.3.6.1.4.1.3181.10.6.1.94.103.1.6
Reflects the administrative setting of this port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), up(1), down(2), testing(3)  

portStatusOperStatus 1.3.6.1.4.1.3181.10.6.1.94.103.1.7
Indicates the combined operation port status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), up(1), down(2), testing(3)  

portStatusDetailedStatus 1.3.6.1.4.1.3181.10.6.1.94.103.1.8
Indicates detailed issues related to the port.
Status: current Access: read-only
OBJECT-TYPE    
  BITS disabled(0), sfpMissing(1), pllNotLocked(2), signalLow(3), tooHigh(4), laserOff(5), loop(6), reserved(7), unknown(8), none(9)  

portStatusPortDatarate 1.3.6.1.4.1.3181.10.6.1.94.103.1.9
Reflects the data rate setting of this port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), txp(1), ms100mEth(2), ms1gEth(3), ms10gEth(4), ms1xFc(10), ms2xFc(11), ms4xFc(12), ms8xFc(13), ms10xFc(14), ms16xFc(15), oc3(20), oc12(21), oc48(22), oc192(23), otu1(30), otu1e(31), otu1f(32), otu2(33), otu2e(34), otu2f(35), fix100(40), escon(41), sdi(42), hdtv(43), tdm2(44), other(45)  

portStatusUpdateTimeStamp 1.3.6.1.4.1.3181.10.6.1.94.103.1.10
Indicates the time when this record was last updated.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

portStatusTimeSinceValueReset 1.3.6.1.4.1.3181.10.6.1.94.103.1.11
Time since when the following statistics have been accumulated. They restart upon module power up or on forced value reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

portStatusTimeSinceLastError 1.3.6.1.4.1.3181.10.6.1.94.103.1.12
Time since last input signal loss or input signal too high.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

portStatusTimeSignalTooLow 1.3.6.1.4.1.3181.10.6.1.94.103.1.13
Total time the input signal was below threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

portStatusSignalTooLowCounter 1.3.6.1.4.1.3181.10.6.1.94.103.1.14
Number of times a transition to signal too low has occured.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

portStatusTimeSignalTooHigh 1.3.6.1.4.1.3181.10.6.1.94.103.1.15
Total time the input signal was above high threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

portStatusSignalTooHighCounter 1.3.6.1.4.1.3181.10.6.1.94.103.1.16
Number of times a transition to signal too high has occured.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

portStatusLowThreshold 1.3.6.1.4.1.3181.10.6.1.94.103.1.17
Defined signal too low threshold.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

portStatusCurrentInputSignal 1.3.6.1.4.1.3181.10.6.1.94.103.1.18
Actual current signal level.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

portStatusHighThreshold 1.3.6.1.4.1.3181.10.6.1.94.103.1.19
Defined signal too high threshold.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

emStatusTable 1.3.6.1.4.1.3181.10.6.1.94.104
Optical amplifier status
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EmStatusEntry

emStatusEntry 1.3.6.1.4.1.3181.10.6.1.94.104.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  EmStatusEntry  

emStatusIndex 1.3.6.1.4.1.3181.10.6.1.94.104.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..11  

emStatusSystemOk 1.3.6.1.4.1.3181.10.6.1.94.104.1.2
True when no errors are present
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

emStatusErrors 1.3.6.1.4.1.3181.10.6.1.94.104.1.3
Indicates various optical error conditions.
Status: current Access: read-only
OBJECT-TYPE    
  BITS lossOfInput(0), lossOfOutput(1), tooHot(2), eyeSafetyShutdown(3), backReflection(4), powerLimit(5), overCurrent(6), pumpDown(7)  

emStatusHardwareCode 1.3.6.1.4.1.3181.10.6.1.94.104.1.4
Details codes about the installed hardware components.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

emStatusTimeSincePowerError 1.3.6.1.4.1.3181.10.6.1.94.104.1.5
How long ago since the last time the output power was in error condition.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

emStatusTimeWithPowerLoss 1.3.6.1.4.1.3181.10.6.1.94.104.1.6
Accumulated time the output power has been down.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

emStatusInputSignalLowCounter 1.3.6.1.4.1.3181.10.6.1.94.104.1.7
Number of times a loss of signal has occured.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

emStatusInputPower 1.3.6.1.4.1.3181.10.6.1.94.104.1.8
Optical input power of port A.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

emStatusSignalGain 1.3.6.1.4.1.3181.10.6.1.94.104.1.9
Indicates how strong the input signal is amplified.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

emStatusOptimalFlatGain 1.3.6.1.4.1.3181.10.6.1.94.104.1.10
Indicates the best gain setting for an even amplification accross the wavelength channels
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

emStatusBackReflection 1.3.6.1.4.1.3181.10.6.1.94.104.1.11
The value should be low and indicates cable issues if not.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

emStatusSignalOutputPower 1.3.6.1.4.1.3181.10.6.1.94.104.1.12
Indicated the actually achieved optical signal output power.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

emStatusTotalOutputPower 1.3.6.1.4.1.3181.10.6.1.94.104.1.13
Indicated the actually achieved optical output power leaving the module (including noise).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

emStatusMinOutputPower 1.3.6.1.4.1.3181.10.6.1.94.104.1.14
Indicates the minimum optical output level that must be send out
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

emStatusMaxOutputPower 1.3.6.1.4.1.3181.10.6.1.94.104.1.15
Indicates the maximum optical output level that can be send out
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

emStatusCfgOutputPower 1.3.6.1.4.1.3181.10.6.1.94.104.1.16
Indicated the desired configured optical output power
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bertStatusTable 1.3.6.1.4.1.3181.10.6.1.94.105
Displays the results of the bit error rate tester (BERT) if it is present and enabled in a slot
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BertStatusEntry

bertStatusEntry 1.3.6.1.4.1.3181.10.6.1.94.105.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  BertStatusEntry  

bertStatusIndex 1.3.6.1.4.1.3181.10.6.1.94.105.1.1
Automatically generated
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..11  

bertStatusLocation 1.3.6.1.4.1.3181.10.6.1.94.105.1.2
Textual description of BERT port location.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bertStatusBertOperation 1.3.6.1.4.1.3181.10.6.1.94.105.1.3
Indicates the general bit error rate tester operational status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unused(0), inSync(1), wasOutOfSync(2), outOfSync(3)  

bertStatusTotalErrors 1.3.6.1.4.1.3181.10.6.1.94.105.1.4
Number of errored bits. Only valid when BERT is synchronized.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

bertStatusTimeSinceLastError 1.3.6.1.4.1.3181.10.6.1.94.105.1.5
Seconds elapsed since the last error was detected.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

bertStatusTotalTestTime 1.3.6.1.4.1.3181.10.6.1.94.105.1.6
Accumulated time how long the test was run since last value clear.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

bertStatusErroredTime 1.3.6.1.4.1.3181.10.6.1.94.105.1.7
Accumulated seconds in which at least on errored bit was detected.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

bertStatusBitErrorRate 1.3.6.1.4.1.3181.10.6.1.94.105.1.8
Averaged bit error rate during test interval.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bertStatusBerSinceLastError 1.3.6.1.4.1.3181.10.6.1.94.105.1.9
Bit error rate since last error.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bertStatusTheoreticalBer 1.3.6.1.4.1.3181.10.6.1.94.105.1.10
Theoretical best possible error rate in the given time frame of the current test interval.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

bertStatusAvailability 1.3.6.1.4.1.3181.10.6.1.94.105.1.11
Relation of transmitted vs. Errored bits.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString