DELL-MM-MIB

File: DELL-MM-MIB.mib (121941 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC-1215
RFC1213-MIB

Imported symbols

enterprises TimeTicks OBJECT-TYPE
TRAP-TYPE DisplayString

Defined Types

DellString  
DisplayString Size(0..1023)    

DellMmType  
INTEGER other(1), unknown(2), mxMM(3)    

DellStatus  
INTEGER other(1), unknown(2), ok(3), nonCritical(4), critical(5), nonRecoverable(6)    

DellPowerReading  
DisplayString Size(0..32)    

DellPowerIndexRange  
INTEGER 1..1    

DellPSUIndexRange  
INTEGER 1..6    

DellPSUCapable  
INTEGER absent(1), none(2), basic(3)    

DellTemperatureReading  
INTEGER    

DellTimestamp  
DisplayString Size(26)    

DmmPowerTableEntry  
SEQUENCE    
  dmmPowerChassisIndex DellPowerIndexRange
  dmmPowerIdlePower DellPowerReading
  dmmPowerKWhCumulative DellPowerReading
  dmmPowerKWhCumulativeTime DellTimestamp
  dmmPowerWattsPeakUsage DellPowerReading
  dmmPowerWattsPeakTime DellTimestamp
  dmmPowerWattsMinUsage DellPowerReading
  dmmPowerWattsMinTime DellTimestamp
  dmmPowerWattsReading DellPowerReading

DmmPSUTableEntry  
SEQUENCE    
  dmmPSUChassisIndex DellPowerIndexRange
  dmmPSUIndex DellPSUIndexRange
  dmmPSULocation DellString
  dmmPSUState DellString
  dmmPSUType DellString
  dmmPSUCapacity DellPowerReading
  dmmPSUVoltage DellPowerReading
  dmmPSUCurrStatus DellStatus

Defined Values

dell 1.3.6.1.4.1.674
OBJECT IDENTIFIER    

server3 1.3.6.1.4.1.674.10892
OBJECT IDENTIFIER    

dmmOutOfBandGroup 1.3.6.1.4.1.674.10892.6
OBJECT IDENTIFIER    

dmmInformationGroup 1.3.6.1.4.1.674.10892.6.1
OBJECT IDENTIFIER    

dmmProductInfoGroup 1.3.6.1.4.1.674.10892.6.1.1
OBJECT IDENTIFIER    

dmmFirmwareGroup 1.3.6.1.4.1.674.10892.6.1.2
OBJECT IDENTIFIER    

dmmStatusGroup 1.3.6.1.4.1.674.10892.6.2
OBJECT IDENTIFIER    

dmmChassisStatusGroup 1.3.6.1.4.1.674.10892.6.3
OBJECT IDENTIFIER    

dmmStatusNowGroup 1.3.6.1.4.1.674.10892.6.3.1
OBJECT IDENTIFIER    

dmmChassisPowerGroup 1.3.6.1.4.1.674.10892.6.4
OBJECT IDENTIFIER    

dmmChassisAlert2Group 1.3.6.1.4.1.674.10892.6.5
OBJECT IDENTIFIER    

dmmChassisAlert2Variables 1.3.6.1.4.1.674.10892.6.5.1
OBJECT IDENTIFIER    

dmmGenericAlertGroup 1.3.6.1.4.1.674.10892.6.6
OBJECT IDENTIFIER    

dmmGenericAlertVariables 1.3.6.1.4.1.674.10892.6.6.1
OBJECT IDENTIFIER    

dmmProductName 1.3.6.1.4.1.674.10892.6.1.1.1
This attribute defines the product name of a chassis management module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmProductShortName 1.3.6.1.4.1.674.10892.6.1.1.2
This attribute defines the short product name of a chassis management module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmProductDescription 1.3.6.1.4.1.674.10892.6.1.1.3
This attribute defines the product description of a chassis management module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmProductManufacturer 1.3.6.1.4.1.674.10892.6.1.1.4
This attribute defines the product manufacturer of a chassis management module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmProductVersion 1.3.6.1.4.1.674.10892.6.1.1.5
This attribute defines the product version of a chassis management module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmChassisServiceTag 1.3.6.1.4.1.674.10892.6.1.1.6
This attribute defines the Service Tag of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmProductURL 1.3.6.1.4.1.674.10892.6.1.1.7
This attribute defines the out-of-band UI URL of a chassis management module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmProductChassisAssetTag 1.3.6.1.4.1.674.10892.6.1.1.8
This attribute defines the Asset Tag of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmProductChassisName 1.3.6.1.4.1.674.10892.6.1.1.9
This attribute defines the name of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmProductType 1.3.6.1.4.1.674.10892.6.1.1.10
This attribute defines type of a remote management module
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellMmType  

dmmProductChassisDataCenter 1.3.6.1.4.1.674.10892.6.1.1.11
This attribute defines the Data Center locator of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmProductChassisAisle 1.3.6.1.4.1.674.10892.6.1.1.12
This attribute defines the Aisle locator of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmProductChassisRack 1.3.6.1.4.1.674.10892.6.1.1.13
This attribute defines the Rack locator of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmProductChassisRackSlot 1.3.6.1.4.1.674.10892.6.1.1.14
This attribute defines the Rack Slot locator of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmProductChassisModel 1.3.6.1.4.1.674.10892.6.1.1.15
This attribute defines the Model of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmProductChassisExpressServiceCode 1.3.6.1.4.1.674.10892.6.1.1.16
This attribute defines the Express Service Code of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmProductChassisSystemID 1.3.6.1.4.1.674.10892.6.1.1.17
This attribute defines the System ID of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dmmFirmwareVersion 1.3.6.1.4.1.674.10892.6.1.2.1
This attribute defines the firmware version of chassis management module 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmFirmwareVersion2 1.3.6.1.4.1.674.10892.6.1.2.2
This attribute defines the firmware version of chassis management module 2.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmGlobalSystemStatus 1.3.6.1.4.1.674.10892.6.2.1
This attribute defines the overall chassis status being monitored by the chassis management module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

dmmIOMCurrStatus 1.3.6.1.4.1.674.10892.6.3.1.1
This attribute defines the IOM subsystem status being monitored by the chassis management module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

dmmRedCurrStatus 1.3.6.1.4.1.674.10892.6.3.1.2
This attribute defines the Redundancy status being monitored by the chassis management module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

dmmPowerCurrStatus 1.3.6.1.4.1.674.10892.6.3.1.3
This attribute defines the power subsystem health status being monitored by the chassis management module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

dmmFanCurrStatus 1.3.6.1.4.1.674.10892.6.3.1.4
This attribute defines the Fan subsystem health status being monitored by the chassis management module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

dmmBladeCurrStatus 1.3.6.1.4.1.674.10892.6.3.1.5
This attribute defines the Blade subsystem health status being monitored by the chassis management module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

dmmTempCurrStatus 1.3.6.1.4.1.674.10892.6.3.1.6
This attribute defines the Temp Sensor subsystem health status being monitored by the chassis management module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

dmmMMCurrStatus 1.3.6.1.4.1.674.10892.6.3.1.7
This attribute defines the health status being monitored by the chassis management module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

dmmChassisFrontPanelAmbientTemperature 1.3.6.1.4.1.674.10892.6.3.1.8
This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis front panel module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellTemperatureReading  

dmmPowerTable 1.3.6.1.4.1.674.10892.6.4.1
This object defines the power table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DmmPowerTableEntry

dmmPowerTableEntry 1.3.6.1.4.1.674.10892.6.4.1.1
This object defines the power table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DmmPowerTableEntry  

dmmPSUTable 1.3.6.1.4.1.674.10892.6.4.2
This object defines the PSU table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DmmPSUTableEntry

dmmPSUTableEntry 1.3.6.1.4.1.674.10892.6.4.2.1
This object defines the PSU table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DmmPSUTableEntry  

dmmPowerChassisIndex 1.3.6.1.4.1.674.10892.6.4.1.1.1
This attribute defines the index (one-based) of the associated chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerIndexRange  

dmmPowerIdlePower 1.3.6.1.4.1.674.10892.6.4.1.1.2
This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the minimum power requirements for all currently powered-on servers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerReading  

dmmPowerKWhCumulative 1.3.6.1.4.1.674.10892.6.4.1.1.3
This attribute defines the cumulative chassis power usage (in KWh) since last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerReading  

dmmPowerKWhCumulativeTime 1.3.6.1.4.1.674.10892.6.4.1.1.4
This attribute defines the timestamp of the most recent chassis power accumulator reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellTimestamp  

dmmPowerWattsPeakUsage 1.3.6.1.4.1.674.10892.6.4.1.1.5
This attribute defines the chassis peak power usage (in Watts) since last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerReading  

dmmPowerWattsPeakTime 1.3.6.1.4.1.674.10892.6.4.1.1.6
This attribute defines the timestamp of the most recent chassis peak power usage.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellTimestamp  

dmmPowerWattsMinUsage 1.3.6.1.4.1.674.10892.6.4.1.1.7
This attribute defines the chassis mimimum power usage (in Watts) since last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerReading  

dmmPowerWattsMinTime 1.3.6.1.4.1.674.10892.6.4.1.1.8
This attribute defines the timestamp of the most recent chassis minimum power usage.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellTimestamp  

dmmPowerWattsReading 1.3.6.1.4.1.674.10892.6.4.1.1.9
This attribute defines the instantaneous chassis power usage (in Watts).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerReading  

dmmPSUChassisIndex 1.3.6.1.4.1.674.10892.6.4.2.1.1
This attribute defines the index (one-based) of the associated chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerIndexRange  

dmmPSUIndex 1.3.6.1.4.1.674.10892.6.4.2.1.2
This attribute defines the index (one-based) of the associated PSU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPSUIndexRange  

dmmPSULocation 1.3.6.1.4.1.674.10892.6.4.2.1.3
This attribute defines the location of the PSU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmPSUState 1.3.6.1.4.1.674.10892.6.4.2.1.4
This attribute defines the enabled state of of the PSU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmPSUType 1.3.6.1.4.1.674.10892.6.4.2.1.5
This attribute defines the type of the PSU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmPSUCapacity 1.3.6.1.4.1.674.10892.6.4.2.1.6
This attribute defines the capacity in watts of the PSU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerReading  

dmmPSUVoltage 1.3.6.1.4.1.674.10892.6.4.2.1.7
This attribute defines the input voltage of the PSU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellPowerReading  

dmmPSUCurrStatus 1.3.6.1.4.1.674.10892.6.4.2.1.8
This attribute defines the current status of the PSU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

dmmCA2MessageID 1.3.6.1.4.1.674.10892.6.5.1.1
Message ID of the alert.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

dmmCA2Message 1.3.6.1.4.1.674.10892.6.5.1.2
Message describing the alert.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmCA2MessageArgs 1.3.6.1.4.1.674.10892.6.5.1.3
Concatenated set of strings representing any message arguments that were used to construct the alert message. Each message argument string is enclosed in double quotes, and there is a comma after the ending double quote of each message argument string, except the last one. Any double quotes found within a message argument string were preprocessed and changed to single quotes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

dmmCA2AlertStatus 1.3.6.1.4.1.674.10892.6.5.1.4
Status of the alert.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellStatus  

dmmCA2FQDD 1.3.6.1.4.1.674.10892.6.5.1.5
Fully qualified device descriptor of device causing the alert.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..512)  

dmmDeviceServiceTag 1.3.6.1.4.1.674.10892.6.6.1.1
Service tag of the device.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DellString  

alert2AmperageProbeNormal 2179
Current sensor reading is within range.
TRAP-TYPE    

alert2AmperageProbeWarning 2178
Current sensor has detected a warning value.
TRAP-TYPE    

alert2AmperageProbeFailure 2177
Current sensor has detected a failure value.
TRAP-TYPE    

alert2BatteryNormal 2227
Battery state has returned to normal; or battery presence had been detected.
TRAP-TYPE    

alert2BatteryWarning 2226
Battery is low.
TRAP-TYPE    

alert2BatteryFailure 2225
Battery has failed or battery is absent.
TRAP-TYPE    

alert2CableFailure 2393
Cable failure.
TRAP-TYPE    

alert2CMCWarning 2546
Chassis Management Module detected a warning.
TRAP-TYPE    

alert2CMCFailure 2545
Chassis Management Module detected an error.
TRAP-TYPE    

alert2FanInformation 2155
Fan information.
TRAP-TYPE    

alert2FanWarning 2154
Fan warning.
TRAP-TYPE    

alert2FanFailure 2153
Fan failure.
TRAP-TYPE    

alert2HardwareConfigurationInformation 2331
Hardware configuration information.
TRAP-TYPE    

alert2HardwareConfigurationWarning 2330
Hardware configuration warning.
TRAP-TYPE    

alert2HardwareConfigurationFailure 2329
Hardware configuration failure or critical event.
TRAP-TYPE    

alert2IOVirtualizationInformation 2555
IO Virtualization information.
TRAP-TYPE    

alert2IOVirtualizationWarning 2554
IO Virtualization warning.
TRAP-TYPE    

alert2IOVirtualizationFailure 2553
IO Virtualization failure or critical event.
TRAP-TYPE    

alert2LinkStatusInformation 2251
Link status information.
TRAP-TYPE    

alert2LinkStatusWarning 2250
Link status warning.
TRAP-TYPE    

alert2LinkStatusFailure 2249
Link status failure or critical event.
TRAP-TYPE    

alert2PowerSupplyNormal 2187
Power supply has returned to normal.
TRAP-TYPE    

alert2PowerSupplyWarning 2186
Power supply has detected a warning.
TRAP-TYPE    

alert2PowerSupplyFailure 2185
Power supply has detected a failure.
TRAP-TYPE    

alert2PowerSupplyAbsent 2465
Power supply is absent.
TRAP-TYPE    

alert2PowerUsageInformation 2275
Power usage information.
TRAP-TYPE    

alert2PowerUsageWarning 2274
Power usage warning.
TRAP-TYPE    

alert2PowerUsageFailure 2273
Power usage failure.
TRAP-TYPE    

alert2RedundancyInformation 2475
Redundancy information.
TRAP-TYPE    

alert2RedundancyDegraded 2474
Redundancy is degraded.
TRAP-TYPE    

alert2RedundancyLost 2473
Redundancy is lost.
TRAP-TYPE    

alert2SecurityInformation 2387
Security information.
TRAP-TYPE    

alert2SecurityWarning 2386
Security warning.
TRAP-TYPE    

alert2SecurityFailure 2385
Security failure or critical event.
TRAP-TYPE    

alert2SystemEventLogInformation 2379
System Event Log information.
TRAP-TYPE    

alert2SystemEventLogWarning 2378
System Event Log warning.
TRAP-TYPE    

alert2SystemEventLogFailure 2377
System Event Log failure or critical event.
TRAP-TYPE    

alert2SoftwareConfigurationInformation 2339
Software configuration information.
TRAP-TYPE    

alert2SoftwareConfigurationWarning 2338
Software configuration warning.
TRAP-TYPE    

alert2SoftwareConfigurationFailure 2337
Software configuration failure.
TRAP-TYPE    

alert2TemperatureProbeNormal 2163
Temperature sensor value is within range.
TRAP-TYPE    

alert2TemperatureProbeWarning 2162
Temperature sensor has detected a warning value.
TRAP-TYPE    

alert2TemperatureProbeFailure 2161
Temperature sensor has detected a failure value.
TRAP-TYPE    

alert2VoltageProbeNormal 2171
Voltage sensor reading is within range.
TRAP-TYPE    

alert2VoltageProbeWarning 2170
Voltage sensor has detected a warning value.
TRAP-TYPE    

alert2VoltageProbeFailure 2169
Voltage sensor has detected a failure value.
TRAP-TYPE    

alert2StorageBatteryInformation 4275
Storage Battery information.
TRAP-TYPE    

alert2StorageBatteryWarning 4274
Storage Battery warning.
TRAP-TYPE    

alert2StorageBatteryFailure 4273
Storage Battery failure.
TRAP-TYPE    

alert2StorageControllerInformation 4331
Storage Controller information.
TRAP-TYPE    

alert2StorageControllerWarning 4330
Storage Controller warning.
TRAP-TYPE    

alert2StorageControllerFailure 4329
Storage Controller failure.
TRAP-TYPE    

alert2StorageEnclosureInformation 4339
Storage Enclosure information.
TRAP-TYPE    

alert2StorageEnclosureWarning 4338
Storage Enclosure warning.
TRAP-TYPE    

alert2StorageEnclosureFailure 4337
Storage Enclosure failure.
TRAP-TYPE    

alert2StorageFanInformation 4203
Storage Fan information.
TRAP-TYPE    

alert2StorageFanWarning 4202
Storage Fan warning.
TRAP-TYPE    

alert2StorageFanFailure 4201
Storage Fan failure.
TRAP-TYPE    

alert2StoragePhysicalDiskInformation 4347
Storage Physical disk information.
TRAP-TYPE    

alert2StoragePhysicalDiskWarning 4346
Storage Physical disk warning.
TRAP-TYPE    

alert2StoragePhysicalDiskFailure 4345
Storage Physical disk failure.
TRAP-TYPE    

alert2StoragePowerSupplyInformation 4235
Storage Power supply information.
TRAP-TYPE    

alert2StoragePowerSupplyWarning 4234
Storage Power supply warning.
TRAP-TYPE    

alert2StoragePowerSupplyFailure 4233
Storage Power supply failure.
TRAP-TYPE    

alert2StorageSecurityInformation 4435
Storage Security information.
TRAP-TYPE    

alert2StorageSecurityWarning 4434
Storage Security warning.
TRAP-TYPE    

alert2StorageSecurityFailure 4433
Storage Security failure or critical event.
TRAP-TYPE    

alert2StorageManagementInformation 4179
Storage Management information. There is no global status change associated with this trap.
TRAP-TYPE    

alert2StorageManagementWarning 4178
Storage Management has detected a device independent warning condition. There is no global status change associated with this trap.
TRAP-TYPE    

alert2StorageManagementFailure 4177
Storage Management has detected a device independent error condition. There is no global status change associated with this trap.
TRAP-TYPE    

alert2StorageTemperatureProbeInformation 4211
Storage Temperature probe information.
TRAP-TYPE    

alert2StorageTemperatureProbeWarning 4210
Storage Temperature probe warning.
TRAP-TYPE    

alert2StorageTemperatureProbeFailure 4209
Storage Temperature probe failure.
TRAP-TYPE    

alert2StorageVirtualDiskInformation 4355
Storage Virtual disk information.
TRAP-TYPE    

alert2StorageVirtualDiskWarning 4354
Storage Virtual disk warning.
TRAP-TYPE    

alert2StorageVirtualDiskFailure 4353
Storage Virtual disk failure.
TRAP-TYPE    

alert2SoftwareChangeUpdateWarning 6314
Software change update warning.
TRAP-TYPE    

alert2CMCAuditInformation 8691
Chassis Management Module audit information.
TRAP-TYPE    

alert2CMCAuditWarning 8690
Chassis Management Module audit warning.
TRAP-TYPE    

alert2CMCAuditFailure 8689
Chassis Management Module audit failure or critical event.
TRAP-TYPE    

alert2IOVirtualizationAuditWarning 8698
IO Virtualization audit warning.
TRAP-TYPE    

alert2LicenseInformation 8515
License information.
TRAP-TYPE    

alert2LicenseWarning 8514
License warning.
TRAP-TYPE    

alert2LicenseFailure 8513
License failure.
TRAP-TYPE    

alert2PCIDeviceAuditWarning 8562
PCI device audit warning.
TRAP-TYPE    

alert2PowerSupplyAuditWarning 8330
Power Supply audit warning.
TRAP-TYPE    

alert2PowerSupplyAuditFailure 8329
Power Supply audit failure or critical event.
TRAP-TYPE    

alert2PowerUsageAuditInformation 8419
Power usage audit information.
TRAP-TYPE    

alert2PowerUsageAuditWarning 8418
Power usage audit warning.
TRAP-TYPE    

alert2PowerUsageAuditFailure 8417
Power usage audit failure or critical event.
TRAP-TYPE    

alert2SoftwareChangeAuditFailure 8361
Software change audit failure or critical event.
TRAP-TYPE    

alert2IOVConfigurationInformation 10747
IO Virtualization configuration information.
TRAP-TYPE    

alert2IOVConfigurationWarning 10746
IO Virtualization configuration warning.
TRAP-TYPE    

alert2PCIDeviceConfigurationInformation 10611
PCI device configuration information.
TRAP-TYPE    

alert2SWCConfigurationWarning 10530
Software configuration warning.
TRAP-TYPE    

alert2SWCConfigurationFailure 10529
Software configuration failure.
TRAP-TYPE    

alert2CMCTestTrap 10395
Test trap generated in response to a user request.
TRAP-TYPE    

alertGenericCritical 100
MM generic critical system alert.
TRAP-TYPE    

alertGenericWarning 200
MM generic warning system alert.
TRAP-TYPE    

alertGenericNormal 300
MM generic normal system alert.
TRAP-TYPE    

alertGenericInformational 400
MM generic information system alert.
TRAP-TYPE    

alertGenericTestTrapEvent 500
MM Generated a test trap event in response to a user request.
TRAP-TYPE