BIANCA-X8000-MIBSYS-MIB

File: BIANCA-X8000-MIBSYS-MIB.mib (10043 bytes)

Imported modules

RFC1155-SMI RFC1158-MIB RFC-1215
RFC-1212

Imported symbols

Counter enterprises DisplayString
TRAP-TYPE OBJECT-TYPE

Defined Values

bintec 1.3.6.1.4.1.272
OBJECT IDENTIFIER    

bibo 1.3.6.1.4.1.272.4
OBJECT IDENTIFIER    

sys 1.3.6.1.4.1.272.4.17
OBJECT IDENTIFIER    

x8 1.3.6.1.4.1.272.4.17.3
OBJECT IDENTIFIER    

sysX8Config 1.3.6.1.4.1.272.4.17.3.1
OBJECT IDENTIFIER    

sysX8Traps 1.3.6.1.4.1.272.4.17.3.2
OBJECT IDENTIFIER    

sysX8ConfigPowerSupply1State 1.3.6.1.4.1.272.4.17.3.1.1
This variable shows the state of the power supply.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER missing(1), off(2), running(3), fail(4)  

sysX8ConfigPowerSupply1Temp 1.3.6.1.4.1.272.4.17.3.1.2
This variable shows the actual power supply temperature in the unit Celsius.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..250  

sysX8ConfigPowerSupply1TempAlarmThreshold 1.3.6.1.4.1.272.4.17.3.1.3
Power supply 1 temperature threshold.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

sysX8ConfigPowerSupply1TempAlarmTrap 1.3.6.1.4.1.272.4.17.3.1.4
If the power supply temperature raises above the threshold, a alarm trap is generated every 60 seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), critical(2)  

sysX8ConfigPowerSupply2State 1.3.6.1.4.1.272.4.17.3.1.5
This variable show the the state of the power supply.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER missing(1), off(2), running(3), fail(4)  

sysX8ConfigPowerSupply2Temp 1.3.6.1.4.1.272.4.17.3.1.6
This variable shows the actual power supply temperature in the unit Celsius.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..250  

sysX8ConfigPowerSupply2TempAlarmThreshold 1.3.6.1.4.1.272.4.17.3.1.7
Power supply 2 temperature threshold.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..250  

sysX8ConfigPowerSupply2TempAlarmTrap 1.3.6.1.4.1.272.4.17.3.1.8
If the power supply temperature raises above the threshold, a alarm trap is generated every 60 seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), critical(2)  

sysX8ConfigFanControl 1.3.6.1.4.1.272.4.17.3.1.9
This variable defines automatic fan control. In mode 'auto' the fans are automatically adjusted depending on the current temperature. In mode 'high' all fans remain at maximum speed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), high(2)  

sysX8ConfigFanVersion 1.3.6.1.4.1.272.4.17.3.1.10
This variable shows the firmware version of the fan unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sysX8ConfigFan1 1.3.6.1.4.1.272.4.17.3.1.11
This variable shows the current turning speed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysX8ConfigFan2 1.3.6.1.4.1.272.4.17.3.1.12
This variable shows the current turning speed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysX8ConfigFan3 1.3.6.1.4.1.272.4.17.3.1.13
This variable shows the current turning speed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysX8ConfigFan4 1.3.6.1.4.1.272.4.17.3.1.14
This variable shows the current turning speed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sysX8TrapPowerSupply1Missing 1
This trap signifies that the power supply 1 has been removed
TRAP-TYPE    

sysX8TrapPowerSupply1PowerOff 2
This trap signifies that the power supply 1 has no power-good signal (no power input)
TRAP-TYPE    

sysX8TrapPowerSupply1PowerFail 3
This trap signifies that the power supply 1 has been in the failure (bad DC output)
TRAP-TYPE    

sysX8TrapPowerSupply1PowerGood 4
This trap signifies that the power supply 1 is running (supplying power)
TRAP-TYPE    

sysX8TrapPowerSupply1TempCritical 5
This trap signifies that the power supply 1 temperature raises above the critical alarm-threshold
TRAP-TYPE    

sysX8TrapPowerSupply1TempOk 6
A normal power supply 1 temperature has been restored.
TRAP-TYPE    

sysX8TrapPowerSupply2Missing 7
This trap signifies that the power supply 2 has been removed
TRAP-TYPE    

sysX8TrapPowerSupply2PowerOff 8
This trap signifies that the power supply 2 has no power-good signal (no power input)
TRAP-TYPE    

sysX8TrapPowerSupply2PowerFail 9
This trap signifies that the power supply 2 has been in the failure (bad DC output)
TRAP-TYPE    

sysX8TrapPowerSupply2PowerGood 10
This trap signifies that the power supply 2 is running (supplying power)
TRAP-TYPE    

sysX8TrapPowerSupply2TempCritical 11
This trap signifies that the power supply 2 temperature raises above the critical alarm-threshold
TRAP-TYPE    

sysX8TrapPowerSupply2TempOk 12
A normal power supply 2 temperature has been restored.
TRAP-TYPE