NonNegativeInteger  
INTEGER    

PositiveInteger  
INTEGER    

UpsConfigScheduleEntry  
SEQUENCE    
  upsConfigScheduleIndex INTEGER
  upsConfigScheduleShutdownDay INTEGER
  upsConfigScheduleShutdownTime DisplayString
  upsConfigScheduleRestartDay INTEGER
  upsConfigScheduleRestartTime DisplayString

UpsConfigTrapsReceiversEntry  
SEQUENCE    
  trapsIndex INTEGER
  trapsReceiverAddr IpAddress
  receiverCommunityString DisplayString
  severityLevel INTEGER
  receiverAccept INTEGER

UpsRegisteredShutdownClientsEntry  
SEQUENCE    
  upsRegisteredShutdownClientsIndex PositiveInteger
  upsRegisteredShutdownClientsIPAddress IpAddress

UpsAlarmEntry  
SEQUENCE    
  upsAlarmIndex PositiveInteger
  upsAlarmName INTEGER
  upsAlarmTime DisplayString

Defined Values

bestPower 1.3.6.1.4.1.2947
OBJECT IDENTIFIER    


upsIdent 1.3.6.1.4.1.2947.1.1
OBJECT IDENTIFIER    

upsBattery 1.3.6.1.4.1.2947.1.2
OBJECT IDENTIFIER    

upsInput 1.3.6.1.4.1.2947.1.3
OBJECT IDENTIFIER    

upsOutput 1.3.6.1.4.1.2947.1.4
OBJECT IDENTIFIER    

upsConfig 1.3.6.1.4.1.2947.1.5
OBJECT IDENTIFIER    

upsControl 1.3.6.1.4.1.2947.1.6
OBJECT IDENTIFIER    

upsTest 1.3.6.1.4.1.2947.1.7
OBJECT IDENTIFIER    

upsAlarm 1.3.6.1.4.1.2947.1.8
OBJECT IDENTIFIER    

upsIdentUpsName 1.3.6.1.4.1.2947.1.1.1
An ID string identifying the Family of UPS.
OBJECT-TYPE    
  DisplayString Size(0..19)  

upsIdentModel 1.3.6.1.4.1.2947.1.1.2
The UPS model name (example: 'FE500VA').
OBJECT-TYPE    
  DisplayString Size(0..29)  

upsIdentVARating 1.3.6.1.4.1.2947.1.1.3
The capacity rating of the UPS expressed in VoltAmperes(VA).
OBJECT-TYPE    
  DisplayString  

upsIdentUpsType 1.3.6.1.4.1.2947.1.1.4
Type of UPS.
OBJECT-TYPE    
  INTEGER standby(1), online(2), offline(3), lineInteractive(4), hybrid(5)  

upsIdentUpsSerialNumber 1.3.6.1.4.1.2947.1.1.5
A unique identification number provided by the factory.
OBJECT-TYPE    
  DisplayString  

upsIdentUpsIdentification 1.3.6.1.4.1.2947.1.1.6
A string entered by the administrator to provide a unique name for the UPS.
OBJECT-TYPE    
  DisplayString  

upsIdentFirmwareRevision 1.3.6.1.4.1.2947.1.1.7
The firmware revision of the UPS.
OBJECT-TYPE    
  DisplayString Size(0..19)  

upsIdentDateOfManufacture 1.3.6.1.4.1.2947.1.1.8
The date when the UPS was manufactured in mm/dd/yyyy format.
OBJECT-TYPE    
  DisplayString Size(6..10)  

upsBatteryStatus 1.3.6.1.4.1.2947.1.2.1
The status of the inverter .
OBJECT-TYPE    
  INTEGER inverterOff(1), inverterOn(2)  

upsBatteryTimeOnBattery 1.3.6.1.4.1.2947.1.2.2
The elapsed time in seconds since the UPS has switched to battery power.
OBJECT-TYPE    
  INTEGER  

upsBatteryRuntimeRemaining 1.3.6.1.4.1.2947.1.2.3
The remaining time in minutes that the UPS will be able to run on battery power.
OBJECT-TYPE    
  INTEGER  

upsBatteryVoltage 1.3.6.1.4.1.2947.1.2.4
The UPS battery voltage expressed in 1/10 VDC.
OBJECT-TYPE    
  INTEGER  

upsBatteryCurrent 1.3.6.1.4.1.2947.1.2.5
The battery current expressed in 1/10 ADC.
OBJECT-TYPE    
  INTEGER  

upsBatteryTemperature 1.3.6.1.4.1.2947.1.2.6
The internal UPS temperature expressed in 1/10 degree C.
OBJECT-TYPE    
  INTEGER  

upsBatteryLastReplaceDate 1.3.6.1.4.1.2947.1.2.7
The date when the UPS system's batteries were last replaced in mm/dd/yyyy format. When the UPS batteries are replaced, this value should be reset by the administrator.
OBJECT-TYPE    
  DisplayString Size(6..10)  

upsInputPhase 1.3.6.1.4.1.2947.1.3.1
The AC input phase.
OBJECT-TYPE    
  INTEGER  

upsInputFrequency 1.3.6.1.4.1.2947.1.3.2
The utility line frequency in 1/10 Hz.
OBJECT-TYPE    
  INTEGER  

upsInputVoltage 1.3.6.1.4.1.2947.1.3.3
The utility line voltage in 1/10 VAC.
OBJECT-TYPE    
  INTEGER  

upsInputCurrent 1.3.6.1.4.1.2947.1.3.4
The utility line current in 1/10 Ampere AC.
OBJECT-TYPE    
  INTEGER  

upsInputPower 1.3.6.1.4.1.2947.1.3.5
The utility line power in 1/10 Watts.
OBJECT-TYPE    
  INTEGER  

upsInputPhase2 1.3.6.1.4.1.2947.1.3.6
OBJECT IDENTIFIER    

upsInputP2 1.3.6.1.4.1.2947.1.3.6.1
The AC input phase.
OBJECT-TYPE    
  INTEGER  

upsInputFrequency2 1.3.6.1.4.1.2947.1.3.6.2
The utility line frequency in 1/10 Hz.
OBJECT-TYPE    
  INTEGER  

upsInputVoltage2 1.3.6.1.4.1.2947.1.3.6.3
The utility line voltage in 1/10 VAC.
OBJECT-TYPE    
  INTEGER  

upsInputCurrent2 1.3.6.1.4.1.2947.1.3.6.4
The utility line current in 1/10 Ampere AC.
OBJECT-TYPE    
  INTEGER  

upsInputPower2 1.3.6.1.4.1.2947.1.3.6.5
The utility line power in 1/10 Watts.
OBJECT-TYPE    
  INTEGER  

upsInputPhase3 1.3.6.1.4.1.2947.1.3.7
OBJECT IDENTIFIER    

upsInputP3 1.3.6.1.4.1.2947.1.3.7.1
The AC input phase.
OBJECT-TYPE    
  INTEGER  

upsInputFrequency3 1.3.6.1.4.1.2947.1.3.7.2
The utility line frequency in 1/10 Hz.
OBJECT-TYPE    
  INTEGER  

upsInputVoltage3 1.3.6.1.4.1.2947.1.3.7.3
The utility line voltage in 1/10 VAC.
OBJECT-TYPE    
  INTEGER  

upsInputCurrent3 1.3.6.1.4.1.2947.1.3.7.4
The utility line current in 1/10 Ampere AC.
OBJECT-TYPE    
  INTEGER  

upsInputPower3 1.3.6.1.4.1.2947.1.3.7.5
The utility line power in 1/10 Watts.
OBJECT-TYPE    
  INTEGER  

upsOutputStatus 1.3.6.1.4.1.2947.1.4.1
The current state of the UPS. If the UPS is unable to determine its state, this variable is set to unknown(1).
OBJECT-TYPE    
  INTEGER unknown(1), onLine(2), onBattery(3), onBypass(4)  

upsOutputPhase 1.3.6.1.4.1.2947.1.4.2
The output phase.
OBJECT-TYPE    
  INTEGER  

upsOutputFrequency 1.3.6.1.4.1.2947.1.4.3
The output frequency of the UPS expressed in 1/10 Hz.
OBJECT-TYPE    
  INTEGER  

upsOutputVoltage 1.3.6.1.4.1.2947.1.4.4
The output voltage of the UPS expressed in 1/10 VAC.
OBJECT-TYPE    
  INTEGER  

upsOutputCurrent 1.3.6.1.4.1.2947.1.4.5
The output current of the UPS expressed in 1/10 AC Amperes.
OBJECT-TYPE    
  NonNegativeInteger  

upsOutputTruePower 1.3.6.1.4.1.2947.1.4.6
The true output power of the UPS expressed in 1/10 Watts.
OBJECT-TYPE    
  NonNegativeInteger  

upsOutputApparentPower 1.3.6.1.4.1.2947.1.4.7
The apparent output power of the UPS expressed in 1/10 VoltAmperes(VA).
OBJECT-TYPE    
  NonNegativeInteger  

upsOutputPowerFactor 1.3.6.1.4.1.2947.1.4.8
The output powerfactor of the UPS expressed in +/- 1/10 units deviating from 1.
OBJECT-TYPE    
  INTEGER  

upsOutputPercentLoad 1.3.6.1.4.1.2947.1.4.9
The percentage of the total UPS power capacity being used expressed in % of 100.
OBJECT-TYPE    
  INTEGER  

upsOutputPhase2 1.3.6.1.4.1.2947.1.4.10
OBJECT IDENTIFIER    

upsOutputP2 1.3.6.1.4.1.2947.1.4.10.1
The output phase.
OBJECT-TYPE    
  INTEGER  

upsOutputFrequency2 1.3.6.1.4.1.2947.1.4.10.2
The output frequency of the UPS expressed in 1/10 Hz.
OBJECT-TYPE    
  INTEGER  

upsOutputVoltage2 1.3.6.1.4.1.2947.1.4.10.3
The output voltage of the UPS expressed in 1/10 VAC.
OBJECT-TYPE    
  INTEGER  

upsOutputCurrent2 1.3.6.1.4.1.2947.1.4.10.4
The output current of the UPS expressed in 1/10 AC Amperes.
OBJECT-TYPE    
  NonNegativeInteger  

upsOutputTruePower2 1.3.6.1.4.1.2947.1.4.10.5
The true output power of the UPS expressed in 1/10 Watts.
OBJECT-TYPE    
  NonNegativeInteger  

upsOutputApparentPower2 1.3.6.1.4.1.2947.1.4.10.6
The apparent output power of the UPS expressed in 1/10 VoltAmperes(VA).
OBJECT-TYPE    
  NonNegativeInteger  

upsOutputPowerFactor2 1.3.6.1.4.1.2947.1.4.10.7
The output powerfactor of the UPS expressed in +\- 1/10 units deviating from 1.
OBJECT-TYPE    
  INTEGER  

upsOutputPhase3 1.3.6.1.4.1.2947.1.4.11
OBJECT IDENTIFIER    

upsOutputP3 1.3.6.1.4.1.2947.1.4.11.1
The output phase.
OBJECT-TYPE    
  INTEGER  

upsOutputFrequency3 1.3.6.1.4.1.2947.1.4.11.2
The output frequency of the UPS expressed in 1/10 Hz.
OBJECT-TYPE    
  INTEGER  

upsOutputVoltage3 1.3.6.1.4.1.2947.1.4.11.3
The output voltage of the UPS expressed in 1/10 VAC.
OBJECT-TYPE    
  INTEGER  

upsOutputCurrent3 1.3.6.1.4.1.2947.1.4.11.4
The output current of the UPS expressed in 1/10 AC Amperes.
OBJECT-TYPE    
  NonNegativeInteger  

upsOutputTruePower3 1.3.6.1.4.1.2947.1.4.11.5
The true output power of the UPS expressed in 1/10 Watts.
OBJECT-TYPE    
  NonNegativeInteger  

upsOutputApparentPower3 1.3.6.1.4.1.2947.1.4.11.6
The apparent output power of the UPS expressed in 1/10 VoltAmperes = (VA).
OBJECT-TYPE    
  NonNegativeInteger  

upsOutputPowerFactor3 1.3.6.1.4.1.2947.1.4.11.7
The output powerfactor of the UPS expressed in +/- 1/10 units deviating from 1.
OBJECT-TYPE    
  INTEGER  

upsConfigLowRuntimeSetpoint 1.3.6.1.4.1.2947.1.5.1
This setpoint controls when the UPS will initiate a Low Runtime Alarm.
OBJECT-TYPE    
  INTEGER  

upsConfigDelayBeforeRestart 1.3.6.1.4.1.2947.1.5.2
The delay in seconds after utility line power returns before the UPS will turn on. This value is used in conjunction with TurnUPSOff, RebootUPS, and the Scheduled Shutdown objects.
OBJECT-TYPE    
  INTEGER  

upsConfigDelayBeforeShutdown 1.3.6.1.4.1.2947.1.5.3
The delay in seconds that the UPS waits before executing an off command upon request of an external device.
OBJECT-TYPE    
  INTEGER  

upsConfigTest 1.3.6.1.4.1.2947.1.5.4
OBJECT IDENTIFIER    

upsConfigTestLevel 1.3.6.1.4.1.2947.1.5.4.1
This is the level of the System Test.
OBJECT-TYPE    
  INTEGER none(1), logic(2), inverter(3), battery(4)  

upsConfigDaysBetweenTests 1.3.6.1.4.1.2947.1.5.4.3
The number of days between Tests.
OBJECT-TYPE    
  INTEGER 0..366  

upsConfigBatteryTestDuration 1.3.6.1.4.1.2947.1.5.4.4
The number of seconds the UPS must run on battery power during a battery test.
OBJECT-TYPE    
  INTEGER 0..9999  

upsConfigScheduleTable 1.3.6.1.4.1.2947.1.5.5
The table to schedule shutting down the ups.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsConfigScheduleEntry

upsConfigScheduleEntry 1.3.6.1.4.1.2947.1.5.5.1
The entries for each day.
OBJECT-TYPE    
  UpsConfigScheduleEntry  

upsConfigScheduleIndex 1.3.6.1.4.1.2947.1.5.5.1.1
The index of scheduled events.
OBJECT-TYPE    
  INTEGER  

upsConfigScheduleShutdownDay 1.3.6.1.4.1.2947.1.5.5.1.2
The weekday on which the UPS should shut down.
OBJECT-TYPE    
  INTEGER sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saturday(7), none(8)  

upsConfigScheduleShutdownTime 1.3.6.1.4.1.2947.1.5.5.1.3
The time that the process of shutting down the UPS will be initiated
OBJECT-TYPE    
  DisplayString  

upsConfigScheduleRestartDay 1.3.6.1.4.1.2947.1.5.5.1.4
The weekday on which the UPS should restart
OBJECT-TYPE    
  INTEGER sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saturday(7), none(8)  

upsConfigScheduleRestartTime 1.3.6.1.4.1.2947.1.5.5.1.5
The time the UPS will restart in hh:mm:ss format.
OBJECT-TYPE    
  DisplayString  


bestLinkHistoryLogFrequency 1.3.6.1.4.1.2947.1.5.8.1
The frequency of updating the history log in minutes.
OBJECT-TYPE    
  INTEGER  

bestLinkRefreshFrequency 1.3.6.1.4.1.2947.1.5.8.2
The frequency of saving configuration,history and event log data in non-volatile memory. If the value is set to 0, then saving data is disabled.
OBJECT-TYPE    
  INTEGER  

bestLinkNetId 1.3.6.1.4.1.2947.1.5.8.3
The IP address of the device. Setting this parameter causes BestLink to reboot.
OBJECT-TYPE    
  IpAddress  

bestLinkGateway 1.3.6.1.4.1.2947.1.5.8.4
The gateway address for the network BestLink is connected to.
OBJECT-TYPE    
  IpAddress  

bestLinkNetMask 1.3.6.1.4.1.2947.1.5.8.5
The net mask of the device.
OBJECT-TYPE    
  IpAddress  

bestLinkSysDate 1.3.6.1.4.1.2947.1.5.8.6
The system date of the device. The date is in mm/dd/yyyy format. The range of system date is from 1/1/1980 to 12/31/2037.
OBJECT-TYPE    
  DisplayString Size(6..10)  

bestLinkSysTime 1.3.6.1.4.1.2947.1.5.8.7
The system time of the device. The time is in hh:mm:ss format.
OBJECT-TYPE    
  DisplayString Size(5..8)  

bestLinkTftpFileName 1.3.6.1.4.1.2947.1.5.8.8
The tftp file name that contains the software upgrade image.
OBJECT-TYPE    
  DisplayString Size(0..59)  

bestLinkTftpHost 1.3.6.1.4.1.2947.1.5.8.9
The tftp host IP address from where to get the image.
OBJECT-TYPE    
  IpAddress  

bestLinkFlashEEPROM 1.3.6.1.4.1.2947.1.5.8.10
Saves the history log, eventlog, and configuration data to non-volatile memory.
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

bestLinkPrimaryTimeServer 1.3.6.1.4.1.2947.1.5.8.11
The primary time server is responsible for sending the correct time to the UPS.
OBJECT-TYPE    
  IpAddress  

bestLinkSecondaryTimeServer 1.3.6.1.4.1.2947.1.5.8.12
The secondary time server responsible for sending the correct time to the UPS.
OBJECT-TYPE    
  IpAddress  

bestLinkSoftwareVersion 1.3.6.1.4.1.2947.1.5.8.13
The version of BestLink software.
OBJECT-TYPE    
  DisplayString  

upsConfigTrapsReceivers 1.3.6.1.4.1.2947.1.5.9
OBJECT IDENTIFIER    

upsConfigTrapsReceiversTable 1.3.6.1.4.1.2947.1.5.9.1
A list of managers to send traps to.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsConfigTrapsReceiversEntry

upsConfigTrapsReceiversEntry 1.3.6.1.4.1.2947.1.5.9.1.1
The managers to send traps to.
OBJECT-TYPE    
  UpsConfigTrapsReceiversEntry  

trapsIndex 1.3.6.1.4.1.2947.1.5.9.1.1.1
The index to a trap receiver entry.
OBJECT-TYPE    
  INTEGER  

trapsReceiverAddr 1.3.6.1.4.1.2947.1.5.9.1.1.2
The IP address of the manager to send a trap to.
OBJECT-TYPE    
  IpAddress  

receiverCommunityString 1.3.6.1.4.1.2947.1.5.9.1.1.3
The community name to use in the trap when sent to the manager.
OBJECT-TYPE    
  DisplayString Size(0..19)  

severityLevel 1.3.6.1.4.1.2947.1.5.9.1.1.4
The severity threshold of traps to send to the manager. Traps are labeled by severity as informational(1), warning(2), severe(3). Only traps of equal or greater severity than this value are sent to the manager.
OBJECT-TYPE    
  INTEGER information(1), warning(2), severe(3)  

receiverAccept 1.3.6.1.4.1.2947.1.5.9.1.1.5
An entry will become active if yes, otherwise it will be disabled.
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

upsConfigRegisteredShutdownClients 1.3.6.1.4.1.2947.1.5.10
OBJECT IDENTIFIER    

upsRegisteredShutdownClientsTable 1.3.6.1.4.1.2947.1.5.10.1
A list of registered shutdown client table entries. The table contains zero, one, or many rows at any moment, depending upon the number of Netwatch clients registered with BestLink
OBJECT-TYPE    
  SEQUENCE OF  
    UpsRegisteredShutdownClientsEntry

upsRegisteredShutdownClientsEntry 1.3.6.1.4.1.2947.1.5.10.1.1
An entry containing information applicable to a particular registered shutdown client.
OBJECT-TYPE    
  UpsRegisteredShutdownClientsEntry  

upsRegisteredShutdownClientsIndex 1.3.6.1.4.1.2947.1.5.10.1.1.1
An index of alarm entries in the RegisteredShutdownClientsTable.
OBJECT-TYPE    
  PositiveInteger  

upsRegisteredShutdownClientsIPAddress 1.3.6.1.4.1.2947.1.5.10.1.1.2
The IP Address of the registered shutdown client
OBJECT-TYPE    
  IpAddress  

upsRegisteredShutdownClientsTotalNumberOf 1.3.6.1.4.1.2947.1.5.10.2
The total number of registered shutdown clients.
OBJECT-TYPE    
  INTEGER  

upsControlTurnOffUPS 1.3.6.1.4.1.2947.1.6.1
Setting this variable to UpsOff(2) causes the UPS to shut off. When the UPS is in the off state, the UPS will remain off until the ON/OFF switch is manually toggled. Setting this variable to cancelUpsOff(1) allows for a method to cancel the upsOff(2) command to the UPS that is still pending, or will make an attempt to restart a UPS that has been shutdown, provided that BestLink is powered by some other means. Setting this variable to rebootUps(3) causes the UPS to shut off and turn back on. Setting this variable to cancelrebootUps(4) allows for a method to cancel the rebootUps(3) command to the UPS that is still pending, or will make an attempt to restart a UPS that has been shutdown, provided that BestLink is powered by some other means.
OBJECT-TYPE    
  INTEGER cancelUpsOff(1), upsOff(2), rebootUps(3), cancelrebootUps(7)  

upsControlActivateUpsScheduling 1.3.6.1.4.1.2947.1.6.4
Setting this variable to On(2) causes the UPS to activate the scheduling parameters that have been previously configured within the upsConfigDailyShutdownScheduleTable and the upsConfigWeeklyShutdownScheduleTable. Setting this variable to Off(1) suspends all currently configured schedules.
OBJECT-TYPE    
  INTEGER off(1), on(2)  

upsManualTests 1.3.6.1.4.1.2947.1.7.1
Setting this variable to any value other than (1) causes the UPS to perform a manual test or abort a particular test in progress.
OBJECT-TYPE    
  INTEGER noTestInitiated(1), initiateManualBeeperTest(2), initiateManualSystemTest(3), initiateManualInverterTest(4), initiateManualBatteryTest(5), abortManualBeeperTest(6), abortManualSystemTest(7), abortManualInverterTest(8), abortManualBatteryTest(9)  

upsAlarmsPresent 1.3.6.1.4.1.2947.1.8.1
The present number of active alarm conditions.
OBJECT-TYPE    
  Gauge  

upsLastKnownAlarm 1.3.6.1.4.1.2947.1.8.2
A unique identifier for an alarm condition. This value must remain constant. Value 'noAlarm(37)' will be returned if no Alarm has occured till the point of GET operation.
OBJECT-TYPE    
  INTEGER onBattery(1), lowRuntime(2), nearLowBattery(3), lowBattery(4), highBattery(5), checkBattery(6), replaceBattery(7), checkInverter(8), batteriesDisconnected(9), outputOverload(10), lowAcOut(11), circuitBreakerWarning(12), circuitBreakerShdn(13), bypassOn(14), autoBypass(15), siteWiringFault(16), checkFan(17), highAmbTemp(18), highHSTemp(19), highXFMRTemp(20), highPFMTemp(21), probeMissing(22), checkPowerSupply(23), tapRegulator(24), relayFailure(25), checkFuse(26), checkMOV(27), memoryError(28), callService(29), upsFailed(30), userTest(31), testInProgress(32), diagnosticTestFailed(33), ePO(34), upsOff(35), communicationsLost(36), noAlarm(37)  

upsAlarmTable 1.3.6.1.4.1.2947.1.8.3
A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with upsAlarmIndex equal to 1, and increments the value of upsAlarmIndex each time a new row is created.
OBJECT-TYPE    
  SEQUENCE OF  
    UpsAlarmEntry

upsAlarmEntry 1.3.6.1.4.1.2947.1.8.3.1
An entry containing information applicable to a particular alarm.
OBJECT-TYPE    
  UpsAlarmEntry  

upsAlarmIndex 1.3.6.1.4.1.2947.1.8.3.1.1
An index of alarm entries in the alarm log.
OBJECT-TYPE    
  PositiveInteger  

upsAlarmName 1.3.6.1.4.1.2947.1.8.3.1.2
A unique identifier for an alarm condition. This value must remain constant.
OBJECT-TYPE    
  INTEGER onBattery(1), lowRuntime(2), nearLowBattery(3), lowBattery(4), highBattery(5), checkBattery(6), replaceBattery(7), checkInverter(8), batteriesDisconnected(9), outputOverload(10), lowAcOut(11), circuitBreakerWarning(12), circuitBreakerShdn(13), bypassOn(14), autoBypass(15), siteWiringFault(16), checkFan(17), highAmbTemp(18), highHSTemp(19), highXFMRTemp(20), highPFMTemp(21), probeMissing(22), checkPowerSupply(23), tapRegulator(24), relayFailure(25), checkFuse(26), checkMOV(27), memoryError(28), callService(29), upsFailed(30), userTest(31), testInProgress(32), diagnosticTestFailed(33), ePO(34), upsOff(35), communicationsLost(36)  

upsAlarmTime 1.3.6.1.4.1.2947.1.8.3.1.3
The time that the alarm occurred in hh:mm:ss format.
OBJECT-TYPE    
  DisplayString  

upsWellKnownAlarms 1.3.6.1.4.1.2947.1.8.4
OBJECT IDENTIFIER    

upsAlarmOnBattery 1.3.6.1.4.1.2947.1.8.4.1
The UPS is drawing power from the batteries.
OBJECT-TYPE    
  INTEGER  

upsAlarmLowRuntime 1.3.6.1.4.1.2947.1.8.4.2
The remaining battery runtime is less than or equal to the upsConfigLowRuntimeSetpoint.
OBJECT-TYPE    
  INTEGER  

upsAlarmNearLowBattery 1.3.6.1.4.1.2947.1.8.4.3
The battery voltage on the UPS has reached a value where the inverter will not be able to function very much longer.
OBJECT-TYPE    
  INTEGER  

upsAlarmLowBattery 1.3.6.1.4.1.2947.1.8.4.4
The battery voltage on the UPS has reached a value where the inverter has stopped providing output power to the connected load equipment. The UPS has shutdown to protect the batteries from complete discharge.
OBJECT-TYPE    
  INTEGER  

upsAlarmHighBattery 1.3.6.1.4.1.2947.1.8.4.5
The battery charger voltage on the UPS has reached a value that is too high for safe battery maintenance.
OBJECT-TYPE    
  INTEGER  

upsAlarmCheckBattery 1.3.6.1.4.1.2947.1.8.4.6
The periodic battery test has failed. A manual test of the batteries needs to be performed to determine which battery\batteries need replaced.
OBJECT-TYPE    
  INTEGER  

upsAlarmReplaceBattery 1.3.6.1.4.1.2947.1.8.4.7
One or more batteries have been determined to require replacement. Compatibility: Fortress II
OBJECT-TYPE    
  INTEGER  

upsAlarmCheckInverter 1.3.6.1.4.1.2947.1.8.4.8
The inverter has failed the automatic system test.
OBJECT-TYPE    
  INTEGER  

upsAlarmBatteriesDisconnected 1.3.6.1.4.1.2947.1.8.4.9
The UPS has detected that the DC voltage needed to start up is too low or missing.
OBJECT-TYPE    
  INTEGER  

upsAlarmOutputOverload 1.3.6.1.4.1.2947.1.8.4.10
The output load exceeds the UPS output capacity.
OBJECT-TYPE    
  INTEGER  

upsAlarmLowAcOut 1.3.6.1.4.1.2947.1.8.4.11
The output load has exceeded the UPS output capacity, and the UPS has shut down.
OBJECT-TYPE    
  INTEGER  

upsAlarmCircuitBreakerWarning 1.3.6.1.4.1.2947.1.8.4.12
To much load equipment has been connected to the UPS and has has caused excess current draw from the output.
OBJECT-TYPE    
  INTEGER  

upsAlarmCircuitBreakerShdn 1.3.6.1.4.1.2947.1.8.4.13
The UPS has shut down due to an extended excess of current draw from the output.
OBJECT-TYPE    
  INTEGER  

upsAlarmBypassOn 1.3.6.1.4.1.2947.1.8.4.14
The Bypass is presently engaged on the UPS.
OBJECT-TYPE    
  INTEGER  

upsAlarmAutoBypass 1.3.6.1.4.1.2947.1.8.4.15
The UPS has gone into the Auto Bypass mode to redirect power around the UPS circuitry.
OBJECT-TYPE    
  INTEGER  

upsAlarmSiteWiringFault 1.3.6.1.4.1.2947.1.8.4.16
The UPS has found a problem in your wall outlet.
OBJECT-TYPE    
  INTEGER  

upsAlarmCheckFan 1.3.6.1.4.1.2947.1.8.4.17
The fan on the UPS has stopped
OBJECT-TYPE    
  INTEGER  

upsAlarmHighAmbTemp 1.3.6.1.4.1.2947.1.8.4.18
The internal temperature inside the UPS is too hot.
OBJECT-TYPE    
  INTEGER  

upsAlarmHighHSTemp 1.3.6.1.4.1.2947.1.8.4.19
The Inverter heatsink assembly inside the UPS is to hot .
OBJECT-TYPE    
  INTEGER  

upsAlarmHighXFMRTemp 1.3.6.1.4.1.2947.1.8.4.20
The temperature of the main transformer inside the UPS is too hot .
OBJECT-TYPE    
  INTEGER  

upsAlarmHighPFMTemp 1.3.6.1.4.1.2947.1.8.4.21
The temperature of the PFM module inside the UPS is too hot .
OBJECT-TYPE    
  INTEGER  

upsAlarmProbeMissing 1.3.6.1.4.1.2947.1.8.4.22
One or all of the sense probes has been disconnected on the UPS.
OBJECT-TYPE    
  INTEGER  

upsAlarmCheckPowerSupply 1.3.6.1.4.1.2947.1.8.4.23
The internal DC supply voltages are attenuated or missing.
OBJECT-TYPE    
  INTEGER  

upsAlarmTapRegulator 1.3.6.1.4.1.2947.1.8.4.24
The UPS detected a possible failure in the tap changer (open or welded relay, etc.)
OBJECT-TYPE    
  INTEGER  

upsAlarmRelayFailure 1.3.6.1.4.1.2947.1.8.4.25
There is a hardware problem inside the UPS.
OBJECT-TYPE    
  INTEGER  

upsAlarmCheckFuse 1.3.6.1.4.1.2947.1.8.4.26
The failure of one or more fuses has been detected.
OBJECT-TYPE    
  INTEGER  

upsAlarmCheckMOV 1.3.6.1.4.1.2947.1.8.4.27
One or more MOVs have failed due to a voltage surge.
OBJECT-TYPE    
  INTEGER  

upsAlarmMemoryError 1.3.6.1.4.1.2947.1.8.4.28
The UPS has lost the programmed settings in the memory of the logic board.
OBJECT-TYPE    
  INTEGER  

upsAlarmCallService 1.3.6.1.4.1.2947.1.8.4.29
A hardware malfunction has occurred inside the UPS. Please consult a factory authorized service representative for assistance.
OBJECT-TYPE    
  INTEGER  

upsAlarmupsFailed 1.3.6.1.4.1.2947.1.8.4.30
A general fault in the UPS has been detected.
OBJECT-TYPE    
  INTEGER  

upsAlarmUserTest 1.3.6.1.4.1.2947.1.8.4.31
A user test of the alarm beeper is in progress.
OBJECT-TYPE    
  INTEGER  

upsAlarmTestInProgress 1.3.6.1.4.1.2947.1.8.4.32
A test is in progress.
OBJECT-TYPE    
  INTEGER  

upsAlarmDiagnosticTestFailed 1.3.6.1.4.1.2947.1.8.4.33
The result of the last diagnostic test indicates a failure.
OBJECT-TYPE    
  INTEGER  

upsAlarmEPO 1.3.6.1.4.1.2947.1.8.4.34
The Emergency Power OFF feature has been activiated at the RS-232 port on the UPS.
OBJECT-TYPE    
  INTEGER  

upsAlarmUpsOff 1.3.6.1.4.1.2947.1.8.4.35
The output of the UPS is in the off state.
OBJECT-TYPE    
  INTEGER  

upsAlarmCommunicationsLost 1.3.6.1.4.1.2947.1.8.4.36
A problem has been encountered in the communications between the agent and the UPS.
OBJECT-TYPE    
  INTEGER