AUTOMATION-SYSTEM-MIB

File: AUTOMATION-SYSTEM-MIB.mib (42847 bytes)

Imported modules

AUTOMATION-SMI AUTOMATION-TC SNMPv2-TC
SNMPv2-SMI SNMPv2-CONF

Imported symbols

automationMgmt AutomationSerialNumberTC AutomationVersionNumberTC
AutomationTriggerTC AutomationOrderNumberTC AutomationFunctionStringTC
AutomationLocationStringTC DisplayString DateAndTime
Counter32 IpAddress Unsigned32
Integer32 OBJECT-TYPE NOTIFICATION-TYPE
MODULE-IDENTITY MODULE-COMPLIANCE OBJECT-GROUP
NOTIFICATION-GROUP

Defined Values

automationSystemMIB 1.3.6.1.4.1.4329.6.3.2
Definition of generic management objects which describe a general I IA product.
MODULE-IDENTITY    

automationSystemObjects 1.3.6.1.4.1.4329.6.3.2.1
OBJECT IDENTIFIER    

automationSystemNotifications 1.3.6.1.4.1.4329.6.3.2.2
OBJECT IDENTIFIER    

automationSystemConformance 1.3.6.1.4.1.4329.6.3.2.3
OBJECT IDENTIFIER    

automationSystemIdent 1.3.6.1.4.1.4329.6.3.2.1.1
OBJECT IDENTIFIER    

automationManufacturerId 1.3.6.1.4.1.4329.6.3.2.1.1.1
A code which identifies the vendor of the component (e. g. the specific department or OEM).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

automationOrderNumber 1.3.6.1.4.1.4329.6.3.2.1.1.2
The type / order number of the system.
Status: current Access: read-only
OBJECT-TYPE    
  AutomationOrderNumberTC  

automationSerialNumber 1.3.6.1.4.1.4329.6.3.2.1.1.3
The serial number of the system.
Status: current Access: read-only
OBJECT-TYPE    
  AutomationSerialNumberTC  

automationHwRevision 1.3.6.1.4.1.4329.6.3.2.1.1.4
The hardware version of the system.
Status: current Access: read-only
OBJECT-TYPE    
  AutomationVersionNumberTC  

automationSwRevision 1.3.6.1.4.1.4329.6.3.2.1.1.5
The firmware version of the system.
Status: current Access: read-only
OBJECT-TYPE    
  AutomationVersionNumberTC  

automationRevisionCounter 1.3.6.1.4.1.4329.6.3.2.1.1.6
This value will be incremented every time one of the other values of automationIM0Group or automationIM1Group (cp. conformance statements) changes. The counter starts with 1 (default configuration).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

automationRevisionDate 1.3.6.1.4.1.4329.6.3.2.1.1.7
The time of the last change of the value of automationRevisionCounter. The value starts with the date of the default configuration. If a system doesn't support an absolute time it must not support the value (cp. conformance statements). If the system supports the ENTITY-MIB the value of this entry correlates to entLastChangeTime.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

automationFunctionTag 1.3.6.1.4.1.4329.6.3.2.1.1.8
A code which describes the function of the component within the plant. This value will be set by the engineering system. It is comparable to the 'sysName'of MIB-II but from the automation point of view.
Status: current Access: read-only
OBJECT-TYPE    
  AutomationFunctionStringTC  

automationLocationTag 1.3.6.1.4.1.4329.6.3.2.1.1.9
A code which describes the location where the component is installed within the plant. This value will be set by the engineering system. It is comparable to the 'sysLocation' of MIB-II but from the automation point of view.
Status: current Access: read-only
OBJECT-TYPE    
  AutomationLocationStringTC  

automationGeoLatitude 1.3.6.1.4.1.4329.6.3.2.1.1.10
geographical latitude of the equipment site shown in one of the following formats: - DD.DDDDDD^ - DD^MM.MMMM' - DD^MM'SS.SS. a leading '+' sign or the trailing letter 'N' indicates northern latitude, a leading '-' sign or the trailing letter 'S' indicates southern latitude. The geodesic reference system is WGS84. Only so many shall be written for fractional digits until the desired precision is represented. Examples: 49.025^, 49^01.5224', 49^01'31.343 N, +49^01'31.343 or 49^01'31.343
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

automationGeoLongitude 1.3.6.1.4.1.4329.6.3.2.1.1.11
geographical longitude of the equipment site shown in one of the following formats: - DDD.DDDDD^ - DDD^MM.MMMM' - DDD^MM'SS.SS a leading '+' sign or the trailing letter 'O' or 'E' indicates eastern longitude, a leading '-' sign or the trailing letter 'W' indicates western longitude, The geodesic reference system is WGS84. Only so many shall be written for fractional digits until the desired precision is represented. Examples: 8.3498^, 8^20.986', 8^20'59.2 E, +8^20'59.2 or 8^20'59.2
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

automationGeoHeight 1.3.6.1.4.1.4329.6.3.2.1.1.12
geographical height of the equipment site in the following format: - dddddd m (high-order zeros are suppressed) a leading sign '-' indicates a height below zero. The geodesic reference system is WGS84. Examples: 158 m, - 20 m
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

automationTimeZoneOffsetHours 1.3.6.1.4.1.4329.6.3.2.1.1.13
The offset hours of the time zone group's time zone from UTC.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -23..23  

automationTimeZoneOffsetMinutes 1.3.6.1.4.1.4329.6.3.2.1.1.14
The offset minutes of the time zone group's time zone from UTC.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -59..59  

automationSwUser 1.3.6.1.4.1.4329.6.3.2.1.1.15
The name of the user who made the last firmware update. The value 'unknown' shall be given, if the user is not known.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

automationSwDate 1.3.6.1.4.1.4329.6.3.2.1.1.16
The time of the last firmware update. The value starts with the date of the default configuration. If a system doesn't support an absolute time it must not support the value.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

automationSystemStatus 1.3.6.1.4.1.4329.6.3.2.1.2
OBJECT IDENTIFIER    

automationOperState 1.3.6.1.4.1.4329.6.3.2.1.2.1
General operational status of the component. ok(0) indicates that the component works, no errors. maintenanceRequired(1) indicates, that at the moment there aren't any problems but maintenace is required e. g. because a service interval has expired or the component determined a software update and so on. maintenanceDemanded(2) indicates, that the component works, but there are problems which could lead to fault situations. fault(3) indicates a failure condition on the component. If a fault-LED is available (on front panel), the fault-LED indication shall be synchronized with the fault value of automationOperState. If the automationOperState signals a fault, the fault-LED must be lit (ON). In all other states of automationOperState the fault-LED is off.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ok(0), maintenanceRequired(1), maintenanceDemanded(2), fault(3)  

automationApplicationOperState 1.3.6.1.4.1.4329.6.3.2.1.2.2
Operating status of the application within the automation system. This status indicates whether the device context is part of an automation system that is in operation (run or stop) or not (no_control).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noControl(1), run(2), stop(3)  

automationSystemGeneric 1.3.6.1.4.1.4329.6.3.2.1.3
OBJECT IDENTIFIER    

automationSystemRestart 1.3.6.1.4.1.4329.6.3.2.1.3.1
Restart the system. Setting the value to 1 causes a coldstart, a value of 2 causes a warmstart. The different behaviour of coldstart and warmstart depends on the component and is described in the user manual of the component. If a warmstart is triggered by the values of 3 or 4 the settings of the component will be reseted to factory defaults. The value of 3 means that only the basic parameters will be reseted, the value of 4 causes a complete reset. Which parameters are affected by this action is described in the components manual. If write access is not allowed, no matter what reason (e.g. an active PROFINET configuration), write requests must be rejected with error 'noSuchName' (SNMPv1 agents) or 'notWriteable' (SNMPv2 and SNMPv3 agents) respectively.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noOperation(0), coldstart(1), warmstart(2), restartBasicDefaults(3), restartCompleteDefaults(4)  

automationPowerUpCount 1.3.6.1.4.1.4329.6.3.2.1.3.3
Number of system starts.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

automationResetCounters 1.3.6.1.4.1.4329.6.3.2.1.3.4
Reset all statistic counters of the component. On write access only a value of set(1) will be accepted (and causes a reset of the counters of the system), all other values will be rejected. If write access is not allowed, no matter what reason (e.g. an active PROFINET configuration), write requests must be rejected with error 'noSuchName' (SNMPv1 agents) or 'notWriteable' (SNMPv2 and SNMPv3 agents) respectively.
Status: current Access: read-write
OBJECT-TYPE    
  AutomationTriggerTC  

automationConfigId 1.3.6.1.4.1.4329.6.3.2.1.3.5
Signature of all configuration parameter values. The special value of all bytes 0x00 denotes the situation of a temporarily not available signature, what might happen during a configuration download while the signature is under construction. If the ConfigId cannot be built, no matter what reason (e.g. incompatibilities between parameter layout and build algorithm, out of resources, ...), get requestes must be responded with error 'noSuchInstance'.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(64)  

automationConfigUser 1.3.6.1.4.1.4329.6.3.2.1.3.6
The name of the user who made the last change to any parameter of the configuration parameter set. The value 'unknown' shall be given, if the user is not known.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

automationConfigDate 1.3.6.1.4.1.4329.6.3.2.1.3.7
The time of the last change to a parameter of the configuration parameter set. The value starts with the date of the default configuration. If a system doesn't support an absolute time it must not support the value (cp. conformance statements).
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

automationSystemIp 1.3.6.1.4.1.4329.6.3.2.1.4
OBJECT IDENTIFIER    

automationSystemIpAddress 1.3.6.1.4.1.4329.6.3.2.1.4.1
This object contains the IP address of the system (which is used to connect to the SNMP agent, the web entity etc.). If the component features an outbandport, this object contains the inband IP address.
Status: deprecated Access: read-write
OBJECT-TYPE    
  IpAddress  

automationSystemIpSubnetMask 1.3.6.1.4.1.4329.6.3.2.1.4.2
This object contains the subnet mask of the system (which is used to connect to the SNMP agent, the webentity etc.). If the component features an outbandport, this object contains the inband subnet mask.
Status: deprecated Access: read-write
OBJECT-TYPE    
  IpAddress  

automationSystemIpGateway 1.3.6.1.4.1.4329.6.3.2.1.4.3
The default gateway of the system.
Status: deprecated Access: read-write
OBJECT-TYPE    
  IpAddress  

automationSystemOutbandIp 1.3.6.1.4.1.4329.6.3.2.1.4.4
If the system features an outband port, this object contains its IP address.
Status: deprecated Access: read-write
OBJECT-TYPE    
  IpAddress  

automationSystemOutbandSubnetMask 1.3.6.1.4.1.4329.6.3.2.1.4.5
If the system features an outband port, this object contains its subnet mask.
Status: deprecated Access: read-write
OBJECT-TYPE    
  IpAddress  

automationSystemNotificationsV2 1.3.6.1.4.1.4329.6.3.2.2.0
OBJECT IDENTIFIER    

automationOperStateChanged 1.3.6.1.4.1.4329.6.3.2.2.0.1
The system triggers this event in case the value of automationOperState changed.
Status: current Access: read-write
NOTIFICATION-TYPE    

automationRevisionChanged 1.3.6.1.4.1.4329.6.3.2.2.0.2
The system triggers this event in case the configuration changed (e. g. the hardware configuration, a firmware update or IP parameter).
Status: current Access: read-write
NOTIFICATION-TYPE    

automationSystemGroups 1.3.6.1.4.1.4329.6.3.2.3.1
OBJECT IDENTIFIER    

automationIM0Group 1.3.6.1.4.1.4329.6.3.2.3.1.1
This group collects the named parameters according to the referenced guideline.
Status: current Access: read-write
OBJECT-GROUP    

automationIM1Group 1.3.6.1.4.1.4329.6.3.2.3.1.2
This group collects the named parameters according to the referenced guideline.
Status: current Access: read-write
OBJECT-GROUP    

automationIM2Group 1.3.6.1.4.1.4329.6.3.2.3.1.3
This group collects the named parameters according to the referenced guideline. The revision date is only available if the system supports an absolute time, therefore this group must be only supported if the absolute time is available.
Status: current Access: read-write
OBJECT-GROUP    

automationStatusGroup 1.3.6.1.4.1.4329.6.3.2.3.1.4
Generic status information.
Status: current Access: read-write
OBJECT-GROUP    

automationRemoteRestartGroup 1.3.6.1.4.1.4329.6.3.2.3.1.5
Allows restart via SNMP.
Status: current Access: read-write
OBJECT-GROUP    

automationResetCounterGroup 1.3.6.1.4.1.4329.6.3.2.3.1.6
Allows reset of all counters.
Status: current Access: read-write
OBJECT-GROUP    

automationIpGroup 1.3.6.1.4.1.4329.6.3.2.3.1.7
IP configuration of the agent.
Status: deprecated Access: read-write
OBJECT-GROUP    

automationOutbandGroup 1.3.6.1.4.1.4329.6.3.2.3.1.8
Configuration of the outband port.
Status: deprecated Access: read-write
OBJECT-GROUP    

automationStatusEvents 1.3.6.1.4.1.4329.6.3.2.3.1.9
Notifications about status changes.
Status: current Access: read-write
NOTIFICATION-GROUP    

automationConfigurationEvents 1.3.6.1.4.1.4329.6.3.2.3.1.10
Notifications about configuration changes.
Status: current Access: read-write
NOTIFICATION-GROUP    

automationGeoLocation 1.3.6.1.4.1.4329.6.3.2.3.1.11
This group collects the named parameters according to the geographical coordinates.
Status: current Access: read-write
OBJECT-GROUP    

automationGeoLocationTimeShift 1.3.6.1.4.1.4329.6.3.2.3.1.12
This group collects the named parameters according to the geographical coordinates and the location dependent time shift.
Status: current Access: read-write
OBJECT-GROUP    

automationConfigIdGroup 1.3.6.1.4.1.4329.6.3.2.3.1.13
This group collects the named parameters for the suppport of a config signature.
Status: current Access: read-write
OBJECT-GROUP    

automationSwDownloadGroup 1.3.6.1.4.1.4329.6.3.2.3.1.14
This group collects the named parameters for a firmware download.
Status: current Access: read-write
OBJECT-GROUP    

automationSystemCompliances 1.3.6.1.4.1.4329.6.3.2.3.2
OBJECT IDENTIFIER    

automationSystemBasicCompliance 1.3.6.1.4.1.4329.6.3.2.3.2.1
Minimum implementation requirements for all Industry Automation Division systems with SNMP support.
Status: current Access: read-write
MODULE-COMPLIANCE    

automationSystemExtCompliance 1.3.6.1.4.1.4329.6.3.2.3.2.2
Extended requirements for Industry Automation Division systems.
Status: deprecated Access: read-write
MODULE-COMPLIANCE    

automationSystemExtCompliance2 1.3.6.1.4.1.4329.6.3.2.3.2.3
Extended requirements for Industry Automation Division systems.
Status: current Access: read-write
MODULE-COMPLIANCE