ALTIGA-SYNC-STATS-MIB
File:
ALTIGA-SYNC-STATS-MIB.mib (11555 bytes)
Imported modules
Imported symbols
Defined Types
AlSyncStatsEntry |
|
SEQUENCE |
|
|
|
|
alSyncStatsRowStatus |
RowStatus |
|
|
alSyncStatsSlot |
Integer32 |
|
|
alSyncStatsConn |
Integer32 |
|
|
alSyncStatsChannel |
Integer32 |
|
|
alSyncStatsIfIndex |
InterfaceIndex |
|
|
alSyncStatsPortState |
INTEGER |
|
|
alSyncStatsRxFrames |
Counter32 |
|
|
alSyncStatsRxOctets |
Counter32 |
|
|
alSyncStatsRxReplenFails |
Counter32 |
|
|
alSyncStatsRxClockErrors |
Counter32 |
|
|
alSyncStatsRxDpllErrors |
Counter32 |
|
|
alSyncStatsRxFrameTooLongErrors |
Counter32 |
|
|
alSyncStatsRxFrameOctetAlignErrors |
Counter32 |
|
|
alSyncStatsRxAbortErrors |
Counter32 |
|
|
alSyncStatsRxCrcErrors |
Counter32 |
|
|
alSyncStatsRxRcvrOverrunErrors |
Counter32 |
|
|
alSyncStatsTxFrames |
Counter32 |
|
|
alSyncStatsTxOctets |
Counter32 |
|
|
alSyncStatsTxRingFullDropsErrors |
Counter32 |
|
|
alSyncStatsTxClockErrors |
Counter32 |
|
|
alSyncStatsTxFrameTooLongErrors |
Counter32 |
|
|
alSyncStatsTxUnderrunErrors |
Counter32 |
|
Defined Values
altigaSyncStatsMibModule |
1.3.6.1.4.1.3076.1.1.37.2 |
The Altiga Sync Statistics MIB models counters and objects
that are of management interest.
Acronyms
The following acronyms are used in this document:
CRC: Cyclic Redundancy Check
HDLC: High-level Data Link Control
MIB: Management Information Base
MTU: Maximum Transmission Unit
|
MODULE-IDENTITY |
|
|
|
alSyncStatsEntry |
1.3.6.1.4.1.3076.2.1.2.32.2.1 |
An entry the alSyncStatsTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AlSyncStatsEntry |
|
|
alSyncStatsSlot |
1.3.6.1.4.1.3076.2.1.2.32.2.1.2 |
The physical slot for this Sync port. Part of the index. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2147483647 |
|
alSyncStatsConn |
1.3.6.1.4.1.3076.2.1.2.32.2.1.3 |
The physical connector for this Sync port. Part of the index. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2147483647 |
|
alSyncStatsChannel |
1.3.6.1.4.1.3076.2.1.2.32.2.1.4 |
The virtual channel for this Sync port. Part of the index. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..2147483647 |
|
alSyncStatsIfIndex |
1.3.6.1.4.1.3076.2.1.2.32.2.1.5 |
The IfIndex of this SYNC slot/conn/channel. This is
configured, but configuration is not available via
SNMP. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
InterfaceIndex |
|
|
alSyncStatsPortState |
1.3.6.1.4.1.3076.2.1.2.32.2.1.6 |
The current operational state of the interface.
The init(1) state indicates the port is in the state
of trying to come up. It will transition to running(2)
once initialization is complete. up(3) indicates the
interface is capable of passing packets. down(4) indicates
the interface is no longer capable of passing packets. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
init(1), running(2), up(3), down(4) |
|
alSyncStatsRxFrames |
1.3.6.1.4.1.3076.2.1.2.32.2.1.7 |
The number of frames received on this HDLC interface. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
alSyncStatsRxOctets |
1.3.6.1.4.1.3076.2.1.2.32.2.1.8 |
The number of octets received on this HDLC interface. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
alSyncStatsRxReplenFails |
1.3.6.1.4.1.3076.2.1.2.32.2.1.9 |
The number of times receive buffers could not be allocated
on this HDLC interface. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
alSyncStatsRxDpllErrors |
1.3.6.1.4.1.3076.2.1.2.32.2.1.11 |
The number of DPLL errors received on this HDLC interface. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
alSyncStatsRxAbortErrors |
1.3.6.1.4.1.3076.2.1.2.32.2.1.14 |
The number of received abort errors received on
this HDLC interface. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
alSyncStatsRxCrcErrors |
1.3.6.1.4.1.3076.2.1.2.32.2.1.15 |
The number of received CRC errors received on
this HDLC interface. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
alSyncStatsTxFrames |
1.3.6.1.4.1.3076.2.1.2.32.2.1.17 |
The number of transmitted frames on this HDLC interface. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
alSyncStatsTxOctets |
1.3.6.1.4.1.3076.2.1.2.32.2.1.18 |
The number of transmitted frames on this HDLC interface. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
alSyncStatsTxRingFullDropsErrors |
1.3.6.1.4.1.3076.2.1.2.32.2.1.19 |
The number of frames dropped on this HDLC interface because
the transmit ring was full. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
alSyncStatsTxClockErrors |
1.3.6.1.4.1.3076.2.1.2.32.2.1.20 |
The number of transmit clock errors on this HDLC interface. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
altigaSyncStatsMibCompliance |
1.3.6.1.4.1.3076.1.1.37.2.1.1.1 |
The compliance statement for agents which
implement the Altiga Sync Statistics MIB. |
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|
altigaSyncStatsGroup |
1.3.6.1.4.1.3076.2.1.1.1.32.2 |
The objects for SYNC configuration. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|