AISLCANALOG-MIB
File:
AISLCANALOG-MIB.mib (16989 bytes)
Imported modules
Imported symbols
Defined Types
Defined Values
aii |
1.3.6.1.4.1.539 |
OBJECT IDENTIFIER |
|
|
|
aiSLCAnalog |
1.3.6.1.4.1.539.28 |
MIB module for SLCs with analog input points. |
MODULE-IDENTITY |
|
|
|
aislcainScanningEnabled |
1.3.6.1.4.1.539.28.1.1.2 |
Enable or disable scanning of the input. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enabled(1), disabled(2) |
|
aislcainDescription |
1.3.6.1.4.1.539.28.1.1.3 |
Textual description of the point.
Maximum length is 80 characters. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
aislcainTrapEnable |
1.3.6.1.4.1.539.28.1.1.4 |
Enable or disable alarm traps. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enabled(1), disabled(2) |
|
aislcainNormalStateTrap |
1.3.6.1.4.1.539.28.1.1.5 |
If enabled, transitions from an alarm state to the normal
state will generate an SNMP trap or TL1 message. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enabled(1), disabled(2) |
|
aislcainHighAlarmSeverity |
1.3.6.1.4.1.539.28.1.1.6 |
Severity of the point's alarm state, or notReported(5)
if the point does not generate an alarm. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
critical(1), major(2), minor(3), info(4), notReported(5) |
|
aislcainHighAlarmStateText |
1.3.6.1.4.1.539.28.1.1.7 |
Textual description of the point's alarm state.
Maximum length is 80 characters. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
aislcainLowAlarmSeverity |
1.3.6.1.4.1.539.28.1.1.8 |
Severity of the point's alarm state, or notReported(5)
if the point does not generate an alarm. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
critical(1), major(2), minor(3), info(4), notReported(5) |
|
aislcainLowAlarmStateText |
1.3.6.1.4.1.539.28.1.1.9 |
Textual description of the point's alarm state.
Maximum length is 80 characters. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
aislcainNormalStateText |
1.3.6.1.4.1.539.28.1.1.10 |
Textual description of the point's normal state.
Maximum length is 80 characters. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
aislcainUserUnits |
1.3.6.1.4.1.539.28.1.1.11 |
The user-defined units for this input (e.g. degC, degF, etc.). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..16) |
|
aislcainHighLimitScan |
1.3.6.1.4.1.539.28.1.1.16 |
If enabled, the high limit threshold will be checked when the input is scanned. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enabled(1), disabled(2) |
|
aislcainHighAlarmThresholdIntervaluu |
1.3.6.1.4.1.539.28.1.1.18 |
The high alarm level threshold interval in user-defined units.
When the high alarm is active, each time the input rises another
interval higher, a new alarm is sent. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
aislcainHighAlarmMinPeriod |
1.3.6.1.4.1.539.28.1.1.19 |
The minimum number of seconds the input(s) should be energized when
the input exceeds the high alarm threshold. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..600 |
|
aislcainHighAlarmHysteresisuu |
1.3.6.1.4.1.539.28.1.1.20 |
The amount by which the input must drop below the High Alarm Threshold
before the High Alarm will be cleared. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
aislcainLowLimitScan |
1.3.6.1.4.1.539.28.1.1.21 |
If enabled, the low limit threshold will be checked when the input is scanned. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enabled(1), disabled(2) |
|
aislcainLowAlarmThresholdIntervaluu |
1.3.6.1.4.1.539.28.1.1.23 |
The low alarm level threshold interval in user-defined units.
When the low alarm is active, each time the input drops another
interval lower, a new alarm is sent. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
aislcainLowAlarmMinPeriod |
1.3.6.1.4.1.539.28.1.1.24 |
The minimum number of seconds the input(s) should be energized when
the input falls below the low alarm threshold. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..600 |
|
aislcainLowAlarmHysteresisuu |
1.3.6.1.4.1.539.28.1.1.25 |
The amount by which the input must rise above the Low Alarm Threshold
before the Low Alarm will be cleared. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
aislcainLastChangeTime |
1.3.6.1.4.1.539.28.1.1.28 |
Textural representation of the time of the most recent
output change. 24-hour format YYYY-MM-DD HH:MM:SS. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(19..23) |
|
aislcaintl1AccessID |
1.3.6.1.4.1.539.28.1.1.29 |
Unique TL1 access identifier for this point.
Maximum length is 22 characters. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..22) |
|
aislcaintl1AccessIDType |
1.3.6.1.4.1.539.28.1.1.31 |
Identifies the point as either an equipment(1) alarm condition
or an environmental(2) alarm. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
equipment(1), environmental(2) |
|
aislcaintl1HighAlarmType |
1.3.6.1.4.1.539.28.1.1.32 |
String indicating the type of alarm, used only
when aislcaintl1AccessIDType is environmental(2).
Maximum length is 10 characters. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..10) |
|
aislcaintl1HighAlarmMessage |
1.3.6.1.4.1.539.28.1.1.33 |
Textual description of the alarm, used only when
aislcaintl1AccessIDType is environmental(2).
Maximum length is 40 characters. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..40) |
|
aislcaintl1LowAlarmType |
1.3.6.1.4.1.539.28.1.1.34 |
String indicating the type of alarm, used only
when aislcaintl1AccessIDType is environmental(2).
Maximum length is 10 characters. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..10) |
|
aislcaintl1LowAlarmMessage |
1.3.6.1.4.1.539.28.1.1.35 |
Textual description of the alarm, used only when
aislcaintl1AccessIDType is environmental(2).
Maximum length is 40 characters. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..40) |
|
aislcaintl1HighAlarmNotificationCode |
1.3.6.1.4.1.539.28.1.1.36 |
Severity of the point's alarm state. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
critical(1), major(2), minor(3) |
|
aislcaintl1HighAlarmServiceAffecting |
1.3.6.1.4.1.539.28.1.1.37 |
Indicates whether or not the alarm affects the functioning
of the equipment. This is only meaningful when
aislcaintl1AccessIDType is equipment(1). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
serviceAffecting(1), notServiceAffecting(2) |
|
aislcaintl1HighAlarmConditionType |
1.3.6.1.4.1.539.28.1.1.38 |
String indicating the type of alarm condition, used
only when aislcaintl1AccessIDType is equipment(1).
Maximum length is 20 characters. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..20) |
|
aislcaintl1HighAlarmConditionDesc |
1.3.6.1.4.1.539.28.1.1.39 |
Textual description of the alarm condition, used only
when aislcaintl1AccessIDType is equipment(1).
Maximum length is 64 characters. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..64) |
|
aislcaintl1LowAlarmNotificationCode |
1.3.6.1.4.1.539.28.1.1.40 |
Severity of the point's alarm state. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
critical(1), major(2), minor(3) |
|
aislcaintl1LowAlarmServiceAffecting |
1.3.6.1.4.1.539.28.1.1.41 |
Indicates whether or not the alarm affects the functioning
of the equipment. This is only meaningful when
aislcaintl1AccessIDType is equipment(1). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
serviceAffecting(1), notServiceAffecting(2) |
|
aislcaintl1LowAlarmConditionType |
1.3.6.1.4.1.539.28.1.1.42 |
String indicating the type of alarm condition, used
only when aislcaintl1AccessIDType is equipment(1).
Maximum length is 20 characters. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..20) |
|
aislcaintl1LowAlarmConditionDesc |
1.3.6.1.4.1.539.28.1.1.43 |
Textual description of the alarm condition, used only
when aislcaintl1AccessIDType is equipment(1).
Maximum length is 64 characters. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..64) |
|
aislcainAnalogStatus |
1.3.6.1.4.1.539.28.1.1.44 |
The current alarm status of the analog input. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normal(1), highLimitExceeded(2), lowLimitExceeded(3), lossOfSignal(4), saturated(5) |
|
aislcainCurrentStateText |
1.3.6.1.4.1.539.28.1.1.45 |
Textual description of the point's current state.
This is either aislcainNormalStateText or aislcainAlarmStateText. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..80) |
|
aislcainAnalogAlarmState |
1.3.6.1.4.1.539.28.1.1.46 |
The point's current alarm state, or normal(5). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
critical(1), major(2), minor(3), info(4), normal(5) |
|