ADTRAN-ATLAS-VOICE-MIB

File: ADTRAN-ATLAS-VOICE-MIB.mib (9537 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB

Imported symbols

enterprises OBJECT-TYPE DisplayString

Defined Types

AdATLASVoiceIfEntry  
SEQUENCE    
  adATLASVoiceIfIndex INTEGER
  adATLASVoiceIfSlotNum INTEGER
  adATLASVoiceIfPortNum INTEGER
  adATLASVoiceIfPortStat INTEGER
  adATLASVoiceIfTxSignalBits DisplayString
  adATLASVoiceIfRxSignalBits DisplayString

AdATLASVoiceTstEntry  
SEQUENCE    
  adATLASVoiceTstIndex INTEGER
  adATLASVoiceTst2W INTEGER
  adATLASVoiceTstTxABCD INTEGER
  adATLASVoiceTst1kHzTone INTEGER
  adATLASVoiceTstLpBk INTEGER

Defined Values

adtran 1.3.6.1.4.1.664
OBJECT IDENTIFIER    

adMgmt 1.3.6.1.4.1.664.2
OBJECT IDENTIFIER    

adATLASmg 1.3.6.1.4.1.664.2.154
OBJECT IDENTIFIER    

adGenATLASmg 1.3.6.1.4.1.664.2.154.1
OBJECT IDENTIFIER    

adATLASVoicemg 1.3.6.1.4.1.664.2.154.1.10
OBJECT IDENTIFIER    

adATLASVoiceIfNumber 1.3.6.1.4.1.664.2.154.1.10.1
The number of voice ports (regardless of their current state) present on this system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

adATLASVoiceIfTable 1.3.6.1.4.1.664.2.154.1.10.2
The ATLAS Voice Interface Status Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AdATLASVoiceIfEntry

adATLASVoiceIfEntry 1.3.6.1.4.1.664.2.154.1.10.2.1
An entry in the ATLAS Voice Interface Status Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AdATLASVoiceIfEntry  

adATLASVoiceIfIndex 1.3.6.1.4.1.664.2.154.1.10.2.1.1
The index value which uniquely identifies the object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

adATLASVoiceIfSlotNum 1.3.6.1.4.1.664.2.154.1.10.2.1.2
This variable indicates the slot number of a particular ATLAS module with a voice interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

adATLASVoiceIfPortNum 1.3.6.1.4.1.664.2.154.1.10.2.1.3
This variable indicates the port number of a particular voice interface on an ATLAS module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

adATLASVoiceIfPortStat 1.3.6.1.4.1.664.2.154.1.10.2.1.4
This variable indicates the call or port status of a particular voice interface on an ATLAS module. Applicable voice interfaces for each option follow: 1 - 4 FXS, FXO, E&M 5 - 8 FXS, FXO 9 - 15 FXS 16 - 20 FXO 21 - 24 E&M
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inactive(1), disabled(2), idle(3), test(4), tipOpen(5), offhook(6), reverseBattery(7), testActive(8), testOffhook(9), testRevBatt(10), testRinging(11), testTipOpen(12), testTipOpenRingGND(13), testDisabled(14), testRingOffhook(15), testLO(16), testLCNormTRPolarity(17), testLCNoBatt(18), testLCRevTRPolarity(19), testRingGND(20), transOnly(21), testELeadOpen(22), testELeadClosed(23), callInProgress(24)  

adATLASVoiceIfTxSignalBits 1.3.6.1.4.1.664.2.154.1.10.2.1.5
Transmit signaling bits: ABCD represented as a character string of 1's and 0's.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

adATLASVoiceIfRxSignalBits 1.3.6.1.4.1.664.2.154.1.10.2.1.6
Receive signaling bits: ABCD represented as a character string of 1's and 0's.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

adATLASVoiceTstTable 1.3.6.1.4.1.664.2.154.1.10.3
The ATLAS Voice Interface Test Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AdATLASVoiceTstEntry

adATLASVoiceTstEntry 1.3.6.1.4.1.664.2.154.1.10.3.1
An entry in the ATLAS Voice Interface Test Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AdATLASVoiceTstEntry  

adATLASVoiceTstIndex 1.3.6.1.4.1.664.2.154.1.10.3.1.1
The index value which uniquely identifies the object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

adATLASVoiceTst2W 1.3.6.1.4.1.664.2.154.1.10.3.1.2
This variable indicates the 2 Wire Test setting on a particular voice interface on an ATLAS module. Applicable voice interfaces for each option follow: 1 FXS, FXO, E&M 2 - 4 FXO 5 - 9 FXS 10 - 11 E&M
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), loopOpen(2), loopClosed(3), ringGround(4), active(5), tipOpen(6), reverseBattery(7), disable(8), ringing(9), eLeadOpen(10), eLeadClosed(11)  

adATLASVoiceTstTxABCD 1.3.6.1.4.1.664.2.154.1.10.3.1.3
This variable indicates the Transmit Signaling Bits Test setting on a particular voice interface on an ATLAS module.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER txOff(1), tx0000(2), tx0101(3), tx1010(4), tx1111(5)  

adATLASVoiceTst1kHzTone 1.3.6.1.4.1.664.2.154.1.10.3.1.4
This variable indicates the Tone Test setting on a particular voice interface on an ATLAS module. Near is for sending tone towards the 2W port. Far is for sending tone towards the PCM (DS0 or B-Channel).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), near(2), far(3)  

adATLASVoiceTstLpBk 1.3.6.1.4.1.664.2.154.1.10.3.1.5
This variable indicates the Loopback Test setting on a particular voice interface on an ATLAS module.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), analog(2), digital(3)