ADSLATUR-MIB

File: ADSLATUR-MIB.mib (34140 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC RFC1213-MIB
ATM-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
IpAddress enterprises DateAndTime
RowStatus ifIndex atmVclVpi
atmVclVci

Defined Types

AdslAturPvcEntry  
SEQUENCE    
  adslAturPvcIndex INTEGER
  adslAturPvcAdminStatus INTEGER
  adslAturPvcIfIndex INTEGER
  adslAturPvcEncapsulation INTEGER
  adslAturPvcBridge INTEGER
  adslAturPvcIGMP INTEGER
  adslAturPvcDHCPClient INTEGER
  adslAturPvcRowStatus RowStatus

AdslAturPPPEntry  
SEQUENCE    
  adslAturPPPIndex INTEGER
  adslAturPPPAdminStatus INTEGER
  adslAturPPPIfIndex INTEGER
  adslAturPPPPhysicalIfIndex INTEGER
  adslAturPPPoEServiceName OCTET STRING
  adslAturPPPDisconnectTimeout INTEGER
  adslAturPPPMSS INTEGER
  adslAturPPPRowStatus RowStatus

AdslAturIPEntry  
SEQUENCE    
  adslAturIpIndex INTEGER
  adslAturIpAdminStatus INTEGER
  adslAturIpPhysicalIfIndex INTEGER
  adslAturIPAddress IpAddress
  adslAturSubnetMask IpAddress
  adslAturGateway IpAddress
  adslAturIPRowStatus RowStatus

AdslAturDHCPServerEntry  
SEQUENCE    
  adslAturDHCPServerIndex INTEGER
  adslAturDHCPServerAdminStatus INTEGER
  adslAturDHCPServerLowerIfIndex INTEGER
  adslAturDHCPServerIpIndex INTEGER
  adslAturDHCPServerAddressPoolSelection INTEGER
  adslAturDHCPServerAddressPoolBeginIp IpAddress
  adslAturDHCPServerAddressPoolEndIp IpAddress
  adslAturDHCPServerGatewaySelection INTEGER
  adslAturDHCPServerGatewayIp IpAddress
  adslAturDHCPServerLeaseTime INTEGER
  adslAturDHCPServerRowStatus RowStatus

AdslAturSysLogEntry  
SEQUENCE    
  adslAturSysLogIndex INTEGER
  adslAturSysLogContent OCTET STRING

Defined Values

adslAtur 1.3.6.1.4.1.4900.1.2.2
Adsl Atur Private Mib.
MODULE-IDENTITY    

adslAturSysInfo 1.3.6.1.4.1.4900.1.2.2.1
OBJECT IDENTIFIER    

adslAturConfig 1.3.6.1.4.1.4900.1.2.2.2
OBJECT IDENTIFIER    

adslAturSysLog 1.3.6.1.4.1.4900.1.2.2.3
OBJECT IDENTIFIER    

adslAturFirmwareUpgrade 1.3.6.1.4.1.4900.1.2.2.4
OBJECT IDENTIFIER    

adslAturDiagnose 1.3.6.1.4.1.4900.1.2.2.5
OBJECT IDENTIFIER    

adslAturTrap 1.3.6.1.4.1.4900.1.2.2.6
OBJECT IDENTIFIER    

adslAturSysInfoSystemTime 1.3.6.1.4.1.4900.1.2.2.1.1
System time specified by Manager after the trap adslAturTrapColdStart has received.
Status: current Access: read-write
OBJECT-TYPE    
  DateAndTime  

adslAturSysInfoMagicNumber 1.3.6.1.4.1.4900.1.2.2.1.2
Magic Number. This magic number is generated based on the system configuration change, and it will change if system configuraiton is changed. It can be used to compare with previous known magic number to detect system configuration change. Trap adslAturTrapColdStart will report this information to SNMP Manager when RTU coldstarts. After that, Manager can get this information any time.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(16)  

adslAturSysInfoFirmwareVersion 1.3.6.1.4.1.4900.1.2.2.1.3
Firmware Version. Trap adslAturTrapColdStart will report this information to Manager when RTU coldstarts. After that, Manager can get this information any time.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

adslAturSysInfoPID 1.3.6.1.4.1.4900.1.2.2.1.4
Product ID. Trap adslAturTrapColdStart will report this information to Manager when RTU coldstarts. After that, Manager can get this information any time.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

adslAturSysInfoVID 1.3.6.1.4.1.4900.1.2.2.1.5
Vendor ID. Trap adslAturTrapColdStart will report this information to Manager when RTU coldstarts. After that, Manager can get this information any time.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

adslAturSysInfoDataPumpVersion 1.3.6.1.4.1.4900.1.2.2.1.6
DataPump version. It is the firmware version of the ADSL data pump module. If the firmware of the data pump module is not separated from the RTU's firmware, it MIGHT have the same version number as the RTU's firmware. Trap adslAturTrapColdStart will report this information to Manager when RTU coldstarts. After that, Manager can get this information any time.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

adslAturConfigSystem 1.3.6.1.4.1.4900.1.2.2.2.1
OBJECT IDENTIFIER    

adslAturConfigSystemReboot 1.3.6.1.4.1.4900.1.2.2.2.1.1
RTU reboot. When Manager set this var to reboot(1), the RTU will reboot immediately. Other values except reboot(1) will be ignored. When RTU reboots, any modified and saved configuration take effect.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reboot(1)  

adslAturConfigSystemSave 1.3.6.1.4.1.4900.1.2.2.2.1.2
Save configuration to RTU's non-volatile memory. When Manager set this var to save(1), the RTU will save current configuration to non-volatile memory such as flash. Other values except save(1) will be ignored.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER save(1)  

adslAturConfigSystemReset 1.3.6.1.4.1.4900.1.2.2.2.1.3
Reset to RTU's null configuration or default configuration. When Manager set this var to resetToNull(1), the RTU will be resetted to null configuration; When Manager set this var to resetToDefault(1), the RTU will be resetted to default configuration. Other values will be ignored.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER resetToNull(1), resetToDefault(2)  

adslAturConfigSystemTrapEnable 1.3.6.1.4.1.4900.1.2.2.2.1.4
Toggle RTU Trap Send status. The default value is enabled(2). When Manager set this var to disabled(1), the RTU will not send trap any more until Manager set it back to enabled(2) again; adslAturConfigSystemTrapEnable will always start as enabled when RTU boots up, and the modified value of adslAturConfigSystemTrapEnable will not be saved when adslAturConfigSystemSave is set to 1(save). Other values will be ignored.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

adslAturConfigAdslLine 1.3.6.1.4.1.4900.1.2.2.2.2
OBJECT IDENTIFIER    

adslAturConfigAdslLineTrellis 1.3.6.1.4.1.4900.1.2.2.2.2.1
Adsl trellis coding, disabled or enabled. See G.DMT for detail.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

adslAturConfigAdslLineHandshake 1.3.6.1.4.1.4900.1.2.2.2.2.2
Adsl handshake protocol selection. See G.DMT for detail.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER autosense-g-dmt-first(1), autosense-t1-413-first(2), g-dmt-or-g-lite(3), t1-413(4), g-dmt(5), g-lite(6)  

adslAturConfigAdslLineBitSwapping 1.3.6.1.4.1.4900.1.2.2.2.2.3
Bit swapping, disabled or enabled. See G.DMT for detail.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

adslAturPvcTable 1.3.6.1.4.1.4900.1.2.2.2.3
The table includes the following extension items about Pvc configuration: 1. encapsulation (adslAturPvcEncapsulation) 2. bridge (adslAturPvcBridge) 3. IGMP (adslAturPvcIGMP) 4. DHCP Client (adslAturPvcDHCPClient) See AdslAturPvcEntry's definition below for detail.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AdslAturPvcEntry

adslAturPvcEntry 1.3.6.1.4.1.4900.1.2.2.2.3.1
An entry of adslAturPvcTable. See AdslAturPvcEntry's definition below for detail.
Status: current Access: not-accessible
OBJECT-TYPE    
  AdslAturPvcEntry  

adslAturPvcIndex 1.3.6.1.4.1.4900.1.2.2.2.3.1.1
The index of Pvc Table. It equals to the PVC instance Id. For example, for a RTU with 8 PVC: PVC1 to PVC8, the index PVC5 should be 5.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

adslAturPvcAdminStatus 1.3.6.1.4.1.4900.1.2.2.2.3.1.2
This Pvc's admin status, enabled or disabled.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

adslAturPvcIfIndex 1.3.6.1.4.1.4900.1.2.2.2.3.1.3
This PVC interface's location in ifTable, will be found by walking the entries with PVC types in ifTable and a specific instance Id(adslAturPvcIndex).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

adslAturPvcEncapsulation 1.3.6.1.4.1.4900.1.2.2.2.3.1.4
This Pvc's encapsulation.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER encapPPPoA-VC-Mux(1), encap1483-Bridged-IP-LLC(2), encap1483-Routed-IP-LLC(3), encapClassical-IP-over-ATM(4), encapPPPoE-LLC(5)  

adslAturPvcBridge 1.3.6.1.4.1.4900.1.2.2.2.3.1.5
This Pvc's bridge mode, disabled or enabled. If a PVC is bridge enabled, packets from this PVC side are transparently bridged to the LAN side, and packets from LAN side are transparently bridged to this PVC.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

adslAturPvcIGMP 1.3.6.1.4.1.4900.1.2.2.2.3.1.6
This Pvc's IGMP mode, disabled or enabled.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

adslAturPvcDHCPClient 1.3.6.1.4.1.4900.1.2.2.2.3.1.7
This Pvc's DHCP Client mode, disabled or enabled. if a PVC's DHCP client is enabled, A DHCP client will be started to get an IP configuration from DHCP servers.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

adslAturPvcRowStatus 1.3.6.1.4.1.4900.1.2.2.2.3.1.8
This object is used to create a new row or modify or delete an existing row in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

adslAturPPPTable 1.3.6.1.4.1.4900.1.2.2.2.4
The table extends ppp configuration by including: 1. Service name (adslAturPPPoEServiceName) 2. Disconnect Timeout (adslAturPPPDisconnectTimeout) 3. MSS (adslAturPPPMSS) See AdslAturPPPEntry's definition below for detail.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AdslAturPPPEntry

adslAturPPPEntry 1.3.6.1.4.1.4900.1.2.2.2.4.1
An entry of adslAturPPPTable. See AdslAturPPPEntry's definition below for detail.
Status: current Access: not-accessible
OBJECT-TYPE    
  AdslAturPPPEntry  

adslAturPPPIndex 1.3.6.1.4.1.4900.1.2.2.2.4.1.1
The index of PPP Table. It equals to the PPP instance Id. For example, for RTU with a maximum 16 PPP: PPP1 through PPP16, the index of PPP2 should be 2.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

adslAturPPPAdminStatus 1.3.6.1.4.1.4900.1.2.2.2.4.1.2
This PPP entry's admin status, disabled or enabled.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

adslAturPPPIfIndex 1.3.6.1.4.1.4900.1.2.2.2.4.1.3
This PPP entry's location in ifTable, will be found by walking the entries with PPP types in ifTable and a specific instance Id(adslAturPPPIndex).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

adslAturPPPPhysicalIfIndex 1.3.6.1.4.1.4900.1.2.2.2.4.1.4
The location of this PPP entry's physical interface (e.g. the PVC interface)in ifTable.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 150000..150007  

adslAturPPPoEServiceName 1.3.6.1.4.1.4900.1.2.2.2.4.1.5
PPPOE Service Name of this PPP connection if the underlying interface is of PPPOE encapsulation. A NULL string can be used to specify ANY service name.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..31)  

adslAturPPPDisconnectTimeout 1.3.6.1.4.1.4900.1.2.2.2.4.1.6
PPP Idle Disconnect Timeout. If a non-zero adslAturPPPDisconnectTimeout is specified, the PPP connection will be disconnected if there is no outbound traffic on the PPP for the specified period. If adslAturPPPDisconnectTimeout is 0, the PPP connection will not be disconnected just because the connection is idle.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..32767  

adslAturPPPMSS 1.3.6.1.4.1.4900.1.2.2.2.4.1.7
PPP MSS(Maximum Segment Size). To ensure interoperability with other hosts on the Internet, The MSS of any TCP connection established on this PPP connection will be reduced to the specified value if a larger value is requested during TCP handshake.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..32767  

adslAturPPPRowStatus 1.3.6.1.4.1.4900.1.2.2.2.4.1.8
This object is used to create a new row or modify or delete an existing row in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

adslAturIPTable 1.3.6.1.4.1.4900.1.2.2.2.5
The table includes the following: 1. IP Address (adslAturIPAddress) 2. Subnet Mask (adslAturSubnetMask) 3. Gateway (adslAturGateway) See AdslAturIPEntry's definition below for detail.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AdslAturIPEntry

adslAturIPEntry 1.3.6.1.4.1.4900.1.2.2.2.5.1
An entry of adslAturIPTable. See AdslAturIPEntry's definition below for detail.
Status: current Access: not-accessible
OBJECT-TYPE    
  AdslAturIPEntry  

adslAturIpIndex 1.3.6.1.4.1.4900.1.2.2.2.5.1.1
The index of IP Table.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

adslAturIpAdminStatus 1.3.6.1.4.1.4900.1.2.2.2.5.1.2
This IP entry's admin status, disabled or enabled.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

adslAturIpPhysicalIfIndex 1.3.6.1.4.1.4900.1.2.2.2.5.1.3
The location of this IP entry's physical interface (either PVC or PPP)in ifTable.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

adslAturIPAddress 1.3.6.1.4.1.4900.1.2.2.2.5.1.4
This IP entry's IP address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

adslAturSubnetMask 1.3.6.1.4.1.4900.1.2.2.2.5.1.5
This IP entry's Subnet Mask.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

adslAturGateway 1.3.6.1.4.1.4900.1.2.2.2.5.1.6
This IP entry's Gateway.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

adslAturIPRowStatus 1.3.6.1.4.1.4900.1.2.2.2.5.1.7
This object is used to create a new row or modify or delete an existing row in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

adslAturDHCPServerTable 1.3.6.1.4.1.4900.1.2.2.2.6
The DHCP Server table. See AdslAturDHCPServerEntry's definition below for detail.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AdslAturDHCPServerEntry

adslAturDHCPServerEntry 1.3.6.1.4.1.4900.1.2.2.2.6.1
An entry of adslAturDHCPServerTable. See AdslAturDHCPServerEntry's definition below for detail.
Status: current Access: not-accessible
OBJECT-TYPE    
  AdslAturDHCPServerEntry  

adslAturDHCPServerIndex 1.3.6.1.4.1.4900.1.2.2.2.6.1.1
The index of DHCP Server table.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

adslAturDHCPServerAdminStatus 1.3.6.1.4.1.4900.1.2.2.2.6.1.2
This DHCP Server entry's admin status, disabled or enabled.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

adslAturDHCPServerLowerIfIndex 1.3.6.1.4.1.4900.1.2.2.2.6.1.3
The IfIndex of the interface on top which the DHCP server operates.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

adslAturDHCPServerIpIndex 1.3.6.1.4.1.4900.1.2.2.2.6.1.4
the IpIndex of adslAturIPEntry, on top of which DHCP server operates.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

adslAturDHCPServerAddressPoolSelection 1.3.6.1.4.1.4900.1.2.2.2.6.1.5
How the address pool of the DHCP server is allocated. If systemAllocated is selected, DHCP server allocates IP address pool based on RTU LAN and WAN configuration. If userDefined is selected, DHCP server uses the address pool as specified by adslAturDHCPServerAddressPoolBeginIp, adslAturDHCPServerAddressPoolEndIp, adslAturDHCPServerGatewaySelection, adslAturDHCPServerGatewayIp, and adslAturDHCPServerLeaseTime.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER systemAllocated(1), userDefined(2)  

adslAturDHCPServerAddressPoolBeginIp 1.3.6.1.4.1.4900.1.2.2.2.6.1.6
The begin IP address of DHCP IP Pool.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

adslAturDHCPServerAddressPoolEndIp 1.3.6.1.4.1.4900.1.2.2.2.6.1.7
The End IP address of DHCP IP Pool.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

adslAturDHCPServerGatewaySelection 1.3.6.1.4.1.4900.1.2.2.2.6.1.8
How the gateway IP address is determined.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER automatic(1), userDefined(2)  

adslAturDHCPServerGatewayIp 1.3.6.1.4.1.4900.1.2.2.2.6.1.9
The user defined gateway IP address of DHCP IP Pool.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

adslAturDHCPServerLeaseTime 1.3.6.1.4.1.4900.1.2.2.2.6.1.10
The lease time in terms of seconds.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..2147483647  

adslAturDHCPServerRowStatus 1.3.6.1.4.1.4900.1.2.2.2.6.1.11
This object is used to create a new row or modify or delete an existing row in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

adslAturNat 1.3.6.1.4.1.4900.1.2.2.2.7
OBJECT IDENTIFIER    

adslAturNatAdminStatus 1.3.6.1.4.1.4900.1.2.2.2.7.1
NAT Mode: disabled, NAT, NAPT, or dynamic NAPT. NAT mode provides Network Address Translation service. Static NAT sessions are required. NAPT mode provides Network Address and Port Translation. Static NAT sessions are required at present for multiple WAN configuration, but not for single WAN configuration. Dynamic NAPT mode provides Network Address and Port Translation. No static NAT sessions are required.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), nat(2), napt(3), dnapt(4)  

adslAturSysLogBeginTime 1.3.6.1.4.1.4900.1.2.2.3.1
The start point of SysLog specified by Manager.
Status: current Access: read-write
OBJECT-TYPE    
  DateAndTime  

adslAturSysLogEndTime 1.3.6.1.4.1.4900.1.2.2.3.2
The end point of SysLog specified by Manager.
Status: current Access: read-write
OBJECT-TYPE    
  DateAndTime  

adslAturSysLogTable 1.3.6.1.4.1.4900.1.2.2.3.3
SysLog table confined by adslAturSysLogBeginTime and adslAturSysLogEndTime. It is a subset of the actual SysLog table in RTU.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AdslAturSysLogEntry

adslAturSysLogEntry 1.3.6.1.4.1.4900.1.2.2.3.3.1
An entry of adslAturSysLogTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  AdslAturSysLogEntry  

adslAturSysLogIndex 1.3.6.1.4.1.4900.1.2.2.3.3.1.1
The index of adslAturSysLogEntry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

adslAturSysLogContent 1.3.6.1.4.1.4900.1.2.2.3.3.1.2
The content of adslAturSysLogEntry.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

adslAturSysLogTrigger 1.3.6.1.4.1.4900.1.2.2.3.4
This is the trigger to start syslog fetch. When Manager set this var to start(1), the Manager will begin to fetch all the entries in adslAturSysLogTable. Other values except start(1) will be ignored.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER start(1)  

adslAturUpgradeIP 1.3.6.1.4.1.4900.1.2.2.4.1
The IP Address where to upgrade.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

adslAturUpgradeUSER 1.3.6.1.4.1.4900.1.2.2.4.3
The Username required when upgrade.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..127)  

adslAturUpgradePASSWD 1.3.6.1.4.1.4900.1.2.2.4.4
The Password required when upgrade.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..127)  

adslAturUpgradePATH 1.3.6.1.4.1.4900.1.2.2.4.5
The PATH(and FILENAME) of the file to be upgraded.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4..255)  

adslAturUpgradeStatus 1.3.6.1.4.1.4900.1.2.2.4.6
This is the state indication when upgrading firmware. After having finished saving firmware to non-volatile memory, RTU agent will send a trap (adslAturTrapUpgradeSuccess) to Manager to indicate upgrade status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notUpgrade(1), connectOK(2), connectFailed(3), downloading(4), downloadOK(5), downloadFailed(6), saving(7), saveFailed(8), upgradeOK(9), upgradeFailed(10)  

adslAturFTPOperCode 1.3.6.1.4.1.4900.1.2.2.4.7
The FTP operation code. When Manager set this var to firmwareUpgrade(1), the RTU will begin to upgrade firmware. Other values, say, throughputTest(2) and dataBackup(3) are not supported yet.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER firmwareUpgrade(1), throughputTest(2), dataBackup(3)  

adslAturDiagnosePing 1.3.6.1.4.1.4900.1.2.2.5.1
OBJECT IDENTIFIER    

adslAturPingAddr 1.3.6.1.4.1.4900.1.2.2.5.1.1
The aim address to be pinged.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4..255)  

adslAturPingPkgSize 1.3.6.1.4.1.4900.1.2.2.5.1.2
The size(bytes) of a packet to be pinged.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 32..4096  

adslAturPingCount 1.3.6.1.4.1.4900.1.2.2.5.1.3
The count of packets to be pinged.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..32767  

adslAturPingResult 1.3.6.1.4.1.4900.1.2.2.5.1.4
The result of ping. The format is following: Aim IP Address=xxx.xxx.xxx.xxx Sent=xx Received=xx Lost=xx Min=xxms Max=xxms Average=xxms
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

adslAturPingStatus 1.3.6.1.4.1.4900.1.2.2.5.1.5
The status of ping. NotStarted(1) means the ping is not started; Started(2) means the ping is in progress; Over(3) means the ping is over.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notStarted(1), started(2), over(3)  

adslAturPingTrigger 1.3.6.1.4.1.4900.1.2.2.5.1.6
This is the trigger to start PING. When Manager set this var to start(1), the RTU will start to ping immediately. Other values except start(1) will be ignored.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER start(1)  

adslAturTrapColdStart 1.3.6.1.4.1.4900.1.2.2.6.0.1
The TRAP is to report RTU coldstart to Manager. RTU agent will send this trap once every minute until Manager got it. Manager will specify RTU system time(adslAturSysInfoSystemTime) right after having got the trap. Parameters: Magic Number = 00112233445566778899AABBCCDDEEFF Version Number = 110502_REL4_S Product ID = 0x1234 Vendor ID = 0x0572 DataPump Version = 3.25
Status: current Access: read-write
NOTIFICATION-TYPE    

adslAturTrapUpgradeDone 1.3.6.1.4.1.4900.1.2.2.6.0.2
The TRAP is to report RTU upgrade status to Manager.
Status: current Access: read-write
NOTIFICATION-TYPE