-- -- Sonus Networks CONFIDENTIAL -- -- This listing of source code is proprietary and confidential to -- Sonus Networks, Inc. It may not be copied or made available in -- any form (electronic or hard copy) to any person not authorized -- by Sonus Networks, Inc. All rights reserved. -- -- Copyright (C) 2009-2013 -- Sonus Networks, Inc. -- 4 Technology Park Drive -- Westford, MA 01886, U.S.A. -- -- -- Release: 3.0 -- UX-OBJECTS-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, IpAddress, enterprises, Counter32, Counter64, Integer32, TimeTicks FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF InterfaceIndex, InterfaceIndexOrZero, ifIndex FROM IF-MIB PerfCurrentCount, PerfIntervalCount,PerfTotalCount FROM PerfHist-TC-MIB -- [RFC3593] dsx0ConfigEntry FROM DS0-MIB; --iso OBJECT IDENTIFIER ::= { 1 } --org OBJECT IDENTIFIER ::= { iso 3 } --dod OBJECT IDENTIFIER ::= { org 6 } --internet OBJECT IDENTIFIER ::= { dod 1 } --directory OBJECT IDENTIFIER ::= { internet 1 } --mgmt OBJECT IDENTIFIER ::= { internet 2 } --mib-2 OBJECT IDENTIFIER ::= { mgmt 1 } --transmission OBJECT IDENTIFIER ::= { mib-2 10 } --experimental OBJECT IDENTIFIER ::= { internet 3 } --private OBJECT IDENTIFIER ::= { internet 4 } --enterprises OBJECT IDENTIFIER ::= { private 1 } ux MODULE-IDENTITY LAST-UPDATED "200911041705Z" ORGANIZATION "net.com" CONTACT-INFO " TAC E-mail: tac@net.com" DESCRIPTION "The MIB module for net.com entities." REVISION "200911041705Z" DESCRIPTION "This MIB will describe the entries for the UX line of products." ::= { enterprises 177 15 } net OBJECT IDENTIFIER ::= { enterprises 177 } uxObjects OBJECT IDENTIFIER ::= { ux 1 } uxTraps OBJECT IDENTIFIER ::= { ux 2 } uxChassis OBJECT IDENTIFIER ::= {uxObjects 1 } ipTelephony OBJECT IDENTIFIER ::= { uxObjects 5 } chasiDescUX2000 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The description for the UX2000 chassis type" ::= { uxChassis 1 } chasiDescUX1000 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The description for the UX1000 chassis type" ::= { uxChassis 2 } chasiType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The chassis type for the system." ::= { uxChassis 3 } -- -- 1. uxAlarmCfgTable -- The following is the definition of the alarm/event config table, and -- can be used to get a table (or entry) of the configured alarm or event -- uxAlarmCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF UxAlarmCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table gives the information about the alarms and events that this device is capable of generating. When a condition satisfying the alarms configured in this table occurs, an alarm is posted in uxActAlarmTable with associated information." ::= {uxObjects 2} uxAlarmCfgEntry OBJECT-TYPE SYNTAX UxAlarmCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the alarm table" INDEX { uxAlarmIndex } ::= {uxAlarmCfgTable 1} UxAlarmCfgEntry ::= SEQUENCE { uxAlarmIndex INTEGER, uxAlarmID INTEGER, uxAlarmSubID INTEGER, uxAlarmCondition DisplayString, uxAlarmSeverity INTEGER, uxAlarmCategory INTEGER, uxAlarmCancelType INTEGER, uxAlarmEvtType INTEGER, uxAlarmDecodeKey DisplayString, uxAlarmClrID INTEGER, uxAlarmClrSubID INTEGER, uxAlarmDescription DisplayString } uxAlarmIndex OBJECT-TYPE SYNTAX INTEGER (1..2147418112) MAX-ACCESS read-only STATUS current DESCRIPTION "Index of this alarm/event in the config table. This will be the combination of uxAlarmID and uxAlarmSubID uxAlarmIndex =uxAlarmID *65536+ uxAlarmSubID" ::= { uxAlarmCfgEntry 1 } uxAlarmID OBJECT-TYPE SYNTAX INTEGER (1..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "Event ID of this alarm/event." ::= { uxAlarmCfgEntry 2 } uxAlarmSubID OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Event SubID of this alarm/event." ::= { uxAlarmCfgEntry 3 } uxAlarmCondition OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm/event name." ::= { uxAlarmCfgEntry 4} uxAlarmSeverity OBJECT-TYPE SYNTAX INTEGER{ none(0), warning(1), minor(2), major(3), critical(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm severity level. Eg: none warning minor major critical" ::= { uxAlarmCfgEntry 5 } uxAlarmCategory OBJECT-TYPE SYNTAX INTEGER { communication (1), equipment (2), processing (3), general (4), environmental (5), qos (6), security (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm/event category number. As per Bell Core Standard GR-1248-CORE" ::= { uxAlarmCfgEntry 6} uxAlarmCancelType OBJECT-TYPE SYNTAX INTEGER { autoCancel (1), nonAutoCancel (0) } MAX-ACCESS read-only STATUS current DESCRIPTION "When an alarm is configured as auto-cancel(1), it clears from the UX active alarm table, when the condition causing it goes away. These alarms do not need explicit user intervention to cancel (clear) them. Non-auto-cancel(0) alarm requires user intervention to clear from the active alarm table. User needs to cancel (clear) it explicitly by setting the corresponding column object in the active alarm table." ::= { uxAlarmCfgEntry 7 } uxAlarmEvtType OBJECT-TYPE SYNTAX INTEGER { alarm (1), event (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of the evnt, whether it is an alarm or a normal event" ::= { uxAlarmCfgEntry 8 } uxAlarmDecodeKey OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Decode key that is used to interpret alarm/event instances when the alarms are posted to active alarm Table. The index attribute uxAlarmInstanceID is decoded based on the value of this attribute. Eg: Decode Key - shelf;card;port Possible decode keys are: shelf, shelf;card, shelf;interface;card;port, service, channel, username, IPAddress, etc.. AFFECTS: uxAlarmInstanceID This attribute affects uxAlarmInstanceID as explained in the example above." ::= { uxAlarmCfgEntry 9 } uxAlarmClrID OBJECT-TYPE SYNTAX INTEGER (1..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "Clearing event Event ID of this alarm. Applicable to the alarms for which the auto clear is set" ::= { uxAlarmCfgEntry 10 } uxAlarmClrSubID OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Clearing event Event sub ID of this alarm. Applicable to the alarms for which the auto clear is set." ::= { uxAlarmCfgEntry 11 } uxAlarmDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm description. Any info user wants to note" ::= { uxAlarmCfgEntry 12 } uxActAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF UxActAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Active Alarm table in the system" ::= {uxObjects 3} uxActAlarmEntry OBJECT-TYPE SYNTAX UxActAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the active alarm table" INDEX { uxAlarmActiveIndex } ::= {uxActAlarmTable 1} UxActAlarmEntry ::= SEQUENCE { uxAlarmActiveIndex INTEGER, uxAlarmConfigIndex INTEGER, uxAlarmActiveID INTEGER, uxAlarmActiveSubID INTEGER, uxAlarmActiveCondition DisplayString, uxAlarmActiveSeverity INTEGER, uxAlarmActiveCategory INTEGER, uxAlarmActiveCancelType INTEGER, uxAlarmActiveFirstOccur Counter64, uxAlarmActiveLastOccur Counter64, uxAlarmActiveCount INTEGER, uxAlarmActiveDecodeKey DisplayString, uxAlarmActiveSourceInstance DisplayString, uxAlarmActiveState INTEGER, uxAlarmActiveClrEvtID INTEGER, uxAlarmActiveClrEvtSubID INTEGER, uxAlarmActiveDescription DisplayString, uxAlarmActiveHighestSeverityAlarm INTEGER, uxAlarmActiveHardWareID DisplayString } uxAlarmActiveIndex OBJECT-TYPE SYNTAX INTEGER (1..2147418112) MAX-ACCESS read-only STATUS current DESCRIPTION "Index of Active alarm table" ::= { uxActAlarmEntry 1 } uxAlarmConfigIndex OBJECT-TYPE SYNTAX INTEGER (1..2147418112) MAX-ACCESS read-only STATUS current DESCRIPTION "Index value of Alarm configuration number" ::= { uxActAlarmEntry 2 } uxAlarmActiveID OBJECT-TYPE SYNTAX INTEGER (1..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "EventID of the active alarm" ::= { uxActAlarmEntry 3 } uxAlarmActiveSubID OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "EventID of the active alarm" ::= { uxActAlarmEntry 4 } uxAlarmActiveCondition OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Active alarm/event name." ::= { uxActAlarmEntry 5} uxAlarmActiveSeverity OBJECT-TYPE SYNTAX INTEGER{ none(0), warning(1), minor(2), major(3), critical(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm severity level. Eg: none warning minor major critical" ::= { uxActAlarmEntry 6 } uxAlarmActiveCategory OBJECT-TYPE SYNTAX INTEGER { communication (1), equipment (2), processing (3), general (4), environmental (5), qos (6), security (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm/event category number. As per Bell Core Standard GR-1248-CORE" ::= { uxActAlarmEntry 7} uxAlarmActiveCancelType OBJECT-TYPE SYNTAX INTEGER { autoCancel (1), nonAutoCancel (0) } MAX-ACCESS read-only STATUS current DESCRIPTION "When an alarm is configured as auto-cancel(1), it clears from the UX active alarm table, when the condition causing it goes away. These alarms do not need explicit user intervention to cancel (clear) them. Non-auto-cancel(0) alarm requires user intervention to clear from the active alarm table. User needs to cancel (clear) it explicitly by setting the corresponding column object in the active alarm table." ::= { uxActAlarmEntry 8 } uxAlarmActiveFirstOccur OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm first occurrence Time displayed in milli sec." ::= { uxActAlarmEntry 9 } uxAlarmActiveLastOccur OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm last occurrence Time displayed in milli sec." ::= { uxActAlarmEntry 10 } uxAlarmActiveCount OBJECT-TYPE SYNTAX INTEGER (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of times this alert occurred. This count is relevant only for non-auto-cancelling alerts." ::= { uxActAlarmEntry 11} uxAlarmActiveDecodeKey OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Decode key that is used to interpret alarm/event instances when the alarms are posted to active alarm Table. The index attribute uxAlarmInstanceID is decoded based on the value of this attribute. Eg: Decode Key - shelf;card;port Possible decode keys are: shelf, shelf;card, shelf;interface;card;port, service, channel, username, IPAddress, etc.. AFFECTS: uxAlarmInstanceID This attribute affects uxAlarmInstanceID as explained in the example above." ::= { uxActAlarmEntry 12 } uxAlarmActiveSourceInstance OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Instance that has generated this alert. This is encoded as illustrated in the following example : decode key = shelf;card;port Source instance = 1;1;1 indicates that the alert is generated on shelf 1 card 1 and port 1 DEPENDS ON: uxAlarmDecodeKey Management station will use uxAlarmDecodeKey to decode this instance." ::= { uxActAlarmEntry 13 } uxAlarmActiveState OBJECT-TYPE SYNTAX INTEGER{ acklnowledged(1), unacknowledged(2), cancel(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Informs if an active alarm is acknowledged/unacknowledged/cancelled." ::= { uxActAlarmEntry 14 } uxAlarmActiveClrEvtID OBJECT-TYPE SYNTAX INTEGER (1..32767) MAX-ACCESS read-only STATUS current DESCRIPTION "Clearing event Event ID of this alarm. Applicable to the alarms for which the auto clear is set" ::= { uxActAlarmEntry 15} uxAlarmActiveClrEvtSubID OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Clearing event Event sub ID of this alarm. Applicable to the alarms for which the auto clear is set." ::= { uxActAlarmEntry 16 } uxAlarmActiveDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm description. Any info user wants to note" ::= { uxActAlarmEntry 17 } uxAlarmActiveHighestSeverityAlarm OBJECT-TYPE SYNTAX INTEGER (0..5) MAX-ACCESS read-only STATUS current DESCRIPTION "Highest Severity Active alarm" ::= { uxActAlarmEntry 18 } uxAlarmActiveHardWareID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware ID of the node" ::= { uxActAlarmEntry 19 } -- -- 6. uxDSPResourceTable -- The following is the definition of the DSP resource- can be used to get a table (or entry) of the DSP resources in UX -- uxDSPResourceTable OBJECT-TYPE SYNTAX SEQUENCE OF UxDSPResourceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table gives the information about the DSP resources in UX." ::= {uxObjects 6} uxDSPResourceEntry OBJECT-TYPE SYNTAX UxDSPResourceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DSP resource table" INDEX { uxDSPIndex } ::= {uxDSPResourceTable 1} UxDSPResourceEntry ::= SEQUENCE { uxDSPIndex INTEGER, uxDSPModType DisplayString, uxDSPIsPresent INTEGER, uxDSPCPUUsage INTEGER, uxDSPChannelsInUse INTEGER, uxDSPServiceStatus INTEGER, uxCodecsSupported DisplayString } uxDSPIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "DSP Resource table index" ::= { uxDSPResourceEntry 1} uxDSPModType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "DSP module type " ::= { uxDSPResourceEntry 2} uxDSPIsPresent OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "If the DSP resource is present. This is because we list all the possible DSP resources through this table and this object specifies if the DSP resource is actually installed on UX." ::= { uxDSPResourceEntry 3} uxDSPCPUUsage OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "DSP Resource usage in % rounded of to the next integer. " ::= { uxDSPResourceEntry 4} uxDSPChannelsInUse OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Number of channels in use by this DSP " ::= { uxDSPResourceEntry 5} uxDSPServiceStatus OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Service state of the DSP " ::= { uxDSPResourceEntry 6} uxCodecsSupported OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Codecs supported by this DSP, displayed as a '|' seperated string " ::= { uxDSPResourceEntry 7} -- -- 7. uxDSX0ConfigTable -- The following is extension of the standard DS0 MIB (RFC 2494) definition. -- uxDSX0ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF UxDSX0ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS0 Configuration table." ::= {uxObjects 7} uxDSX0ConfigEntry OBJECT-TYPE SYNTAX UxDSX0ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS0 Configuration table. There is an entry in this table for each DS0 interface." AUGMENTS { dsx0ConfigEntry } ::= { uxDSX0ConfigTable 1 } UxDSX0ConfigEntry ::= SEQUENCE { uxDSX0Type INTEGER, uxDSX0Speed INTEGER, uxDSX0Lastchange INTEGER, uxDSX0AdminState INTEGER } uxDSX0Type OBJECT-TYPE SYNTAX INTEGER{ e1(0), t1(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of DS0" ::= { uxDSX0ConfigEntry 1 } uxDSX0Speed OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Speed of DS0" ::= { uxDSX0ConfigEntry 2 } uxDSX0Lastchange OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Last change of status on this DS0 in EPOCH secs" ::= { uxDSX0ConfigEntry 3 } uxDSX0AdminState OBJECT-TYPE SYNTAX INTEGER{ down(0), up(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Admin state of this DS0" ::= { uxDSX0ConfigEntry 4 } -- -- 8. uxModuleTable -- The following is definition of the Module table on UX. -- The purpose of this table is to provide inventory information of the -- installed on UX platform device -- uxModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF UxModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table gives the information about all the installed Modules in UX." ::= {uxObjects 8} uxModuleEntry OBJECT-TYPE SYNTAX UxModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Module table" INDEX { uxModuleIndex } ::= { uxModuleTable 1 } UxModuleEntry ::= SEQUENCE { uxModuleIndex INTEGER, uxModuleType INTEGER, uxModulePartNumber DisplayString, uxModuleVersionNumber DisplayString, uxModuleSerialNumber DisplayString, uxModuleMfgWeek INTEGER, uxModuleMfgYear INTEGER } uxModuleIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Index of the Module. It also represents the physical location of the card/module on the system. NOTE: For different UX Chassis, the index of modules/cards may differ. " ::= { uxModuleEntry 1 } uxModuleType OBJECT-TYPE SYNTAX INTEGER { unknown(0), dS1-2Spans(1), dS1-4Spans(2), dS1-8Spans(3), eX(4), mSPDC910DSP(5), mSPDC300DSP(6), reservedModule1(7), reservedModule2(8), reservedModule3(9), reservedModule4(10), aSM(11), mainBoard(12), chassis(13), powerSupply(14), reservedModule5(15), node(16), fXS-8PortsLineCard(17), fXS-16PortsLineCard(18), fXS-24PortsLineCard(19), fXS-4PortsLowerBoard(20), fXS-4PortsUpperBoard(21), fXO-4PortsLowerBoard(22), fXO-4PortsUpperBoard(23), bRI-4PortsBoard(24), dS1-1SpanBoard(25), dS1-2SpansBoard(26), fXS-4PortsNRLowerBoard(27) } MAX-ACCESS read-only STATUS current DESCRIPTION "Module type indicating the physical module type. Integer values 7, 8, 9, 10, 15 - reserved for future modules. " ::= { uxModuleEntry 2 } uxModulePartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Module part information Example: 404-40001 " ::= { uxModuleEntry 3 } uxModuleVersionNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Module version information Example: 001 " ::= { uxModuleEntry 4 } uxModuleSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Module serial number information Example: A4000110040059 " ::= { uxModuleEntry 5 } uxModuleMfgWeek OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Module manufacturing week number NOTE: This object is not applicable for uxModuleType of PowerSupply type. For PowerSupply Modules, 0 will be returned. " ::= { uxModuleEntry 6 } uxModuleMfgYear OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Module manufacturing year number NOTE: This object is not applicable for uxModuleType of PowerSupply type. For PowerSupply Modules, 0 will be returned. " ::= { uxModuleEntry 7 } -- -- 9. uxPSUTable -- The following is definition of the Power Supply table on UX. -- The purpose of this table is to provide power supply health and runtime -- information on UX device -- uxPSUTable OBJECT-TYPE SYNTAX SEQUENCE OF UxPSUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides health and runtime information on all Power Supplies on UX. This table returns all applicable power supply slots. NOTE: THIS MIB IS NOT SUPPORTED FOR UX1000 MODEL " ::= {uxObjects 9} uxPSUEntry OBJECT-TYPE SYNTAX UxPSUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the PSU table" INDEX { uxPSUIndex } ::= { uxPSUTable 1 } UxPSUEntry ::= SEQUENCE { uxPSUIndex INTEGER, uxPSUIsPresent INTEGER, uxPSUIsInputGood INTEGER, uxPSUInputType INTEGER, uxPSUPowerIn INTEGER, uxPSUPowerOut INTEGER, uxPSUVoltageIn INTEGER, uxPSUVoltageOut INTEGER, uxPSUCurrentIn INTEGER, uxPSUCurrentOut INTEGER, uxPSUTemperature INTEGER, uxPSUFanSpeed1 INTEGER, uxPSUFanSpeed2 INTEGER } uxPSUIndex OBJECT-TYPE SYNTAX INTEGER (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "Index of the Power Supply. NOTE: UX2000: Index 1, is the left PSU Index 2, is the right PSU " ::= { uxPSUEntry 1 } uxPSUIsPresent OBJECT-TYPE SYNTAX INTEGER {present(1),notpresent(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Provides indication if the power supply is present on the device. " ::= { uxPSUEntry 2 } uxPSUIsInputGood OBJECT-TYPE SYNTAX INTEGER {yes(1), no(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Provides status of PSU Input health. This could be used to deduce the health state of the Power Supply as following: uxPSUIsPresent(1) and yes(1) - Power Supply is Up no(2) - Power Supply is Down " ::= { uxPSUEntry 3 } uxPSUInputType OBJECT-TYPE SYNTAX INTEGER {notapplicable(0), ac(1), dc(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Provides the type of PSU Input i.e. AC or DC" ::= { uxPSUEntry 4 } uxPSUPowerIn OBJECT-TYPE SYNTAX INTEGER (0..500) MAX-ACCESS read-only STATUS current DESCRIPTION "Provides Power (W) coming into the supply" ::= { uxPSUEntry 5 } uxPSUPowerOut OBJECT-TYPE SYNTAX INTEGER (0..500) MAX-ACCESS read-only STATUS current DESCRIPTION "Provides Power (W) going out from the supply" ::= { uxPSUEntry 6 } uxPSUVoltageIn OBJECT-TYPE SYNTAX INTEGER (0..300) MAX-ACCESS read-only STATUS current DESCRIPTION "Provides Voltage coming into the supply" ::= { uxPSUEntry 7 } uxPSUVoltageOut OBJECT-TYPE SYNTAX INTEGER (0..15000) MAX-ACCESS read-only STATUS current DESCRIPTION "Provides Voltage going out from the supply This information is returned in 1000s of the unit value" ::= { uxPSUEntry 8 } uxPSUCurrentIn OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Provides Current (A) coming into the supply This information is returned in 1000s of the unit value" ::= { uxPSUEntry 9 } uxPSUCurrentOut OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Provides Current (A) going out from the supply This information is returned in 1000s of the unit value" ::= { uxPSUEntry 10 } uxPSUTemperature OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Provides temperature (C) of the supply" ::= { uxPSUEntry 11 } uxPSUFanSpeed1 OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Provides speed (RPM) of the Fan 1 of the supply" ::= { uxPSUEntry 12 } uxPSUFanSpeed2 OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Provides speed (RPM) of the Fan 2 of the supply" ::= { uxPSUEntry 13 } -- -- 10. uxFanTable -- The following is definition of the Fan table on UX. -- The purpose of this table is to provide Fan information on UX device -- uxFanTable OBJECT-TYPE SYNTAX SEQUENCE OF UxFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table gives the information about all the installed Fans on UX. NOTE: THIS MIB IS NOT SUPPORTED FOR UX1000 MODEL " ::= {uxObjects 10} uxFanEntry OBJECT-TYPE SYNTAX UxFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Fan table" INDEX { uxFanIndex } ::= { uxFanTable 1 } UxFanEntry ::= SEQUENCE { uxFanIndex INTEGER, uxFanSpeed INTEGER } uxFanIndex OBJECT-TYPE SYNTAX INTEGER (1..9) MAX-ACCESS read-only STATUS current DESCRIPTION "Index of the installed Fan." ::= { uxFanEntry 1 } uxFanSpeed OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Speed (RPM) of the Fan Note: Fan can be considered Down if the speed is 0 " ::= { uxFanEntry 2 } -- -- 11. uxCardTable -- The following is definition of the Card table on UX. -- The purpose of this table is to provide installed Card -- information on UX device -- uxCardTable OBJECT-TYPE SYNTAX SEQUENCE OF UxCardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table gives information about all the installed Cards on UX. NOTE: THIS MIB IS NOT SUPPORTED FOR UX1000 MODEL " ::= {uxObjects 11} uxCardEntry OBJECT-TYPE SYNTAX UxCardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Card table" INDEX { uxCardIndex } ::= { uxCardTable 1 } UxCardEntry ::= SEQUENCE { uxCardIndex INTEGER, uxCardType INTEGER, uxCardServiceStatus INTEGER } uxCardIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Index of the installed Card." ::= { uxCardEntry 1 } uxCardType OBJECT-TYPE SYNTAX INTEGER { unknown(0), dS1-2Spans(1), dS1-4Spans(2), dS1-8Spans(3), eX(4), fXS-8PortsLineCard(17), fXS-16PortsLineCard(18), fXS-24PortsLineCard(19), fXS-4PortsLowerBoard(20), fXS-4PortsUpperBoard(21), fXO-4PortsLowerBoard(22), fXO-4PortsUpperBoard(23), bRI-4PortsBoard(24), dS1-1SpanBoard(25), dS1-2SpansBoard(26), fXS-4PortsNRLowerBoard(27) } MAX-ACCESS read-only STATUS current DESCRIPTION "Card type indicating the physical card type. Integer values 5 to 16 do not indicate a physical card type. " ::= { uxCardEntry 2 } uxCardServiceStatus OBJECT-TYPE SYNTAX INTEGER { down(0), up(1), notapplicable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Operational status of the installed card. Note: This attribute is not applicable for cards/modules on UX1000 hardware. " ::= { uxCardEntry 3 } -- -- UX System Group -- A collection of UX system level information. -- uxSystem OBJECT IDENTIFIER ::= {uxObjects 12 } uxSystemHighestSeverityAlarm OBJECT-TYPE SYNTAX INTEGER{ unknown(0), normal(1), warning(2), minor(3), major(4), critical(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Provides highest severity of all active alarms in the system." ::= { uxSystem 1 } uxSystemCoreSwitchTemp OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Provides core switch temperature (C)." ::= { uxSystem 2 } uxSystemCurrentCPUUsage OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "Provides CPU Usage statistics for the current interval." ::= { uxSystem 3 } uxSystemCurrentMemoryUsage OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "Provides Memory Usage statistics for the current interval." ::= { uxSystem 4 } uxLicenseCurrentPeakSIPCall OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "Peak value of used SIP call licenses for the current 1 hour interval." ::= { uxSystem 5 } uxLicenseCurrentPeakSIPRegistration OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION " Peak value of used SIP Registrations licenses for the current interval." ::= { uxSystem 6 } uxDSPPeakCurrentUsage OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION " Peak DSP usage for the current 1 hour interval." ::= { uxSystem 7} uxLicenseCurrentPeakTDMChannel OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION " Peak value of used TDM channel licenses." ::= { uxSystem 8 } uxLicenseCurrentPeakDSP OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION " Peak value of used DSP licenses." ::= { uxSystem 9 } uxSystemUsageStatsIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF UxSystemUsageIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The System Usage Interval table contains various system usage statitics collected over the previous 4 hours.The past 4 hours are broken into 240 completed 1 minute intervals. Each row in this table represents one such interval ." ::= {ipTelephony 9} uxSystemUsageIntervalEntry OBJECT-TYPE SYNTAX UxSystemUsageIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the System Usage Interval table" INDEX { uxSystemUsageIntervalNumber } ::= {uxSystemUsageStatsIntervalTable 1} UxSystemUsageIntervalEntry ::= SEQUENCE { uxSystemUsageIntervalNumber INTEGER, uxSystemUsageIntervalCPUUsage PerfTotalCount, uxSystemUsageIntervalMemoryUsage PerfTotalCount } uxSystemUsageIntervalNumber OBJECT-TYPE SYNTAX INTEGER (1..240) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 240, where 1 is the most recently completed 1 minute interval and 240 is the 1 minute interval completed 239 minutes prior to interval 1." ::= { uxSystemUsageIntervalEntry 1} uxSystemUsageIntervalCPUUsage OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "CPU Usage statistics for 1 minute interval." ::= { uxSystemUsageIntervalEntry 2} uxSystemUsageIntervalMemoryUsage OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "Memory Usage statistics for 1 minute interval." ::= { uxSystemUsageIntervalEntry 3} uxDSPPeakUsageStatsIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF UxDSPPeakUsageIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DSP Usage Stats table contains various statistics being collected by DSP for the previous 24 hours. The past 24 hours are broken into 24 completed 1 hour intervals. Each row in this table represents one such interval." ::= {ipTelephony 14} uxDSPPeakUsageIntervalEntry OBJECT-TYPE SYNTAX UxDSPPeakUsageIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the System Usage Current table" INDEX { uxDSPPeakUsageIntervalIndex } ::= {uxDSPPeakUsageStatsIntervalTable 1} UxDSPPeakUsageIntervalEntry ::= SEQUENCE { uxDSPPeakUsageIntervalIndex INTEGER, uxDSPPeakIntervalUsage PerfCurrentCount } uxDSPPeakUsageIntervalIndex OBJECT-TYPE SYNTAX INTEGER (1..24) MAX-ACCESS read-only STATUS current DESCRIPTION "The Index value which identifies the interval." ::= { uxDSPPeakUsageIntervalEntry 1} uxDSPPeakIntervalUsage OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "Peak DSP usage." ::= { uxDSPPeakUsageIntervalEntry 2} uxUserStatsPeakSessionsCurrentInerval OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Provides peak number of user sessions in the current interval." ::= {uxSystem 10} uxUserStatsIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF UxUserStatsIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Provides peak number of user sessions for the specified interval." ::= {uxSystem 11} uxUserStatsIntervalEntry OBJECT-TYPE SYNTAX UxUserStatsIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the user statistics interval table." INDEX {uxUserStatsIntervalNumber} ::= {uxUserStatsIntervalTable 1} UxUserStatsIntervalEntry ::= SEQUENCE { uxUserStatsIntervalNumber INTEGER, uxUserStatsPeakSessions INTEGER } uxUserStatsIntervalNumber OBJECT-TYPE SYNTAX INTEGER (1..24) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 24, where 1 is the most recently completed 1 hour interval and 24 is the 1 hour interval completed 23 hours and 45 minutes prior to interval 1." ::= {uxUserStatsIntervalEntry 1} uxUserStatsPeakSessions OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Peak user sessions during the requested interval." ::= {uxUserStatsIntervalEntry 2} END