-- **************************************************************************** -- -- Server Health Features -- Management Information Base for SNMP Network Management -- -- -- Copyright 1992,2008 Hewlett-Packard Development Company, L.P. -- -- Hewlett-Packard Company shall not be liable for technical or -- editorial errors or omissions contained herein. The information in -- this document is provided "as is" without warranty of any kind and -- is subject to change without notice. The warranties for HP products -- are set forth in the express limited warranty statements -- accompanying such products. Nothing herein should be construed as -- constituting an additional warranty. -- -- Confidential computer software. Valid license from HP required for -- possession, use or copying. Consistent with FAR 12.211 and 12.212, -- Commercial Computer Software, Computer Software Documentation, and -- Technical Data for Commercial Items are licensed to the U.S. -- Government under vendor's standard commercial license. -- -- Refer to the READMIB.RDM file for more information about the -- organization of the information in the Compaq Enterprise. -- -- The Compaq Enterprise number is 232. -- The ASN.1 prefix to, and including the Compaq Enterprise is: -- 1.3.6.1.4.1.232 -- -- **************************************************************************** CPQHLTH-MIB DEFINITIONS ::= BEGIN IMPORTS compaq FROM CPQHOST-MIB enterprises FROM RFC1155-SMI Counter FROM RFC1155-SMI DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 sysName FROM RFC1213-MIB cpqHoTrapFlags FROM CPQHOST-MIB cpqSiServerSystemId FROM CPQSINFO-MIB cpqSiMemModuleSize FROM CPQSINFO-MIB; -- compaq OBJECT IDENTIFIER ::= { enterprises 232 } cpqHealth OBJECT IDENTIFIER ::= { compaq 6 } cpqHeMibRev OBJECT IDENTIFIER ::= { cpqHealth 1 } cpqHeComponent OBJECT IDENTIFIER ::= { cpqHealth 2 } cpqHeTrap OBJECT IDENTIFIER ::= { cpqHealth 3 } cpqHeInterface OBJECT IDENTIFIER ::= { cpqHeComponent 1 } cpqHeCriticalError OBJECT IDENTIFIER ::= { cpqHeComponent 2 } cpqHeCorrectableMemory OBJECT IDENTIFIER ::= { cpqHeComponent 3 } cpqHeAsr OBJECT IDENTIFIER ::= { cpqHeComponent 5 } cpqHeThermal OBJECT IDENTIFIER ::= { cpqHeComponent 6 } cpqHePostMsg OBJECT IDENTIFIER ::= { cpqHeComponent 7 } cpqHeSysUtil OBJECT IDENTIFIER ::= { cpqHeComponent 8 } cpqHeFltTolPwrSupply OBJECT IDENTIFIER ::= { cpqHeComponent 9 } cpqHeIRC OBJECT IDENTIFIER ::= { cpqHeComponent 10 } cpqHeEventLog OBJECT IDENTIFIER ::= { cpqHeComponent 11 } cpqHeMgmtDisplay OBJECT IDENTIFIER ::= { cpqHeComponent 12 } cpqHePowerConverter OBJECT IDENTIFIER ::= { cpqHeComponent 13 } cpqHeResilientMemory OBJECT IDENTIFIER ::= { cpqHeComponent 14 } cpqHePowerMeter OBJECT IDENTIFIER ::= { cpqHeComponent 15 } cpqHeOsNetWare3x OBJECT IDENTIFIER ::= { cpqHeInterface 1 } cpqHeOsCommon OBJECT IDENTIFIER ::= { cpqHeInterface 4 } -- **************************************************************************** -- Health MIB Revision -- =================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeMibRev Group (1.3.6.1.4.1.232.6.1) -- -- An Insight Agent conforming to this document will return a -- cpqHeMibRevMajor of one (1) and a cpqHeMibRevMinor of thirty (30). -- -- -- Implementation of the MibRev group is mandatory for all agents -- supporting the Server Health MIB. -- -- **************************************************************************** cpqHeMibRevMajor OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The Major Revision level of the MIB. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of the supported information, correct interpretation of data may require a MIB document with the same major revision level." ::= { cpqHeMibRev 1 } cpqHeMibRevMinor OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The minor revision level of the MIB. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred." ::= { cpqHeMibRev 2 } cpqHeMibCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), -- default degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The overall condition. This object represents the overall status of the server health system represented by this MIB." ::= { cpqHeMibRev 3 } -- **************************************************************************** -- Health MIB NetWare OS Group -- =========================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeInterface Group (1.3.6.1.4.1.232.6.2.1) -- cpqHeOsNetWare3x Group (1.3.6.1.4.1.232.6.2.1.1) -- -- Implementation of the cpqHeOsNetWare3x group is mandatory for all -- agents that support the Server Health MIB in a NetWare host -- operating environment. -- -- **************************************************************************** cpqHeNw3xDriverName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS deprecated DESCRIPTION "Driver Name. This value identifies the NetWare Loadable Module providing the operating system access to the Server Health information." ::= { cpqHeOsNetWare3x 1 } cpqHeNw3xDriverDate OBJECT-TYPE SYNTAX DisplayString (SIZE (8)) ACCESS read-only STATUS deprecated DESCRIPTION "Driver Date. The date of the NetWare Loadable Module providing the operating system access to the Server Health logs. The date is provided in mm/dd/yy format." ::= { cpqHeOsNetWare3x 2 } cpqHeNw3xDriverVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..5)) ACCESS read-only STATUS deprecated DESCRIPTION "Driver Version. This is the version of the NetWare Loadable Module (NLM) providing the operating system access to the Server Health logs." ::= { cpqHeOsNetWare3x 3 } -- **************************************************************************** -- Health MIB OS Common Group -- ========================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeInterface Group (1.3.6.1.4.1.232.6.2.1) -- cpqHeOsCommon Group (1.3.6.1.4.1.232.6.2.1.4) -- -- The cpqHeOsCommon group describes the interface to the Server -- health components. This information describes the interface modules -- and general OS interface architectural information. -- -- Implementation of the cpqHeOsCommon group is mandatory for all -- agents that support the Server Health MIB. -- -- **************************************************************************** cpqHeOsCommonPollFreq OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The Insight Agent's polling frequency. The frequency, in seconds, at which the Insight Agent requests information from the device driver. A frequency of zero indicates that the Insight Agent retrieves the information upon request of a management station, it does not poll the device driver at a specific interval. If the poll frequency is 0 all attempts to write to this object will fail. If the poll frequency is non-zero, setting this value will change the polling frequency of the Insight Agent. Setting the poll frequency to zero will always fail, an agent may also choose to fail any request to change the poll frequency to a value that would severely impact system performance." ::= { cpqHeOsCommon 1 } -- **************************************************************************** -- Health MIB OS Common Module Table -- ================================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeInterface Group (1.3.6.1.4.1.232.6.2.1) -- cpqHeOsCommon Group (1.3.6.1.4.1.232.6.2.1.4) -- cpqHeOsCommonModuleTable (1.3.6.1.4.1.232.6.2.1.4.2) deprecated -- -- **************************************************************************** cpqHeOsCommonModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHeOsCommonModuleEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Supporting software table. This is a table of software modules that provide an interface to the device this server health MIB describes." ::= { cpqHeOsCommon 2 } cpqHeOsCommonModuleEntry OBJECT-TYPE SYNTAX CpqHeOsCommonModuleEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "A description of a software modules that provide an interface to the device this MIB describes." INDEX { cpqHeOsCommonModuleIndex } ::= { cpqHeOsCommonModuleTable 1 } CpqHeOsCommonModuleEntry ::= SEQUENCE { cpqHeOsCommonModuleIndex INTEGER, cpqHeOsCommonModuleName DisplayString, cpqHeOsCommonModuleVersion DisplayString, cpqHeOsCommonModuleDate OCTET STRING, cpqHeOsCommonModulePurpose DisplayString } cpqHeOsCommonModuleIndex OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS deprecated DESCRIPTION "A unique index for this module description." ::= { cpqHeOsCommonModuleEntry 1 } cpqHeOsCommonModuleName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS deprecated DESCRIPTION "The module name." ::= { cpqHeOsCommonModuleEntry 2 } cpqHeOsCommonModuleVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..5)) ACCESS read-only STATUS deprecated DESCRIPTION "The module version in XX.YY format. Where XX is the major version number and YY is the minor version number. This field will be null (size 0) string if the agent cannot provide the module version." ::= { cpqHeOsCommonModuleEntry 3 } cpqHeOsCommonModuleDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (7)) ACCESS read-only STATUS deprecated DESCRIPTION "The module date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the agent cannot provide the module date. The hour, minute, and second field will be set to zero (0) if they are not relevant. The year field is set with the most significant octet first." ::= { cpqHeOsCommonModuleEntry 4 } cpqHeOsCommonModulePurpose OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS deprecated DESCRIPTION "The purpose of the module described in this entry." ::= { cpqHeOsCommonModuleEntry 5 } -- **************************************************************************** -- Health MIB Critical Error Group -- =============================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeCriticalError Group (1.3.6.1.4.1.232.6.2.2) -- -- The cpqHeCriticalError group describes the health critical error log. -- -- Implementation of the cpqHeCriticalError group is mandatory for all -- agents that support the Server Health MIB. -- -- **************************************************************************** cpqHeCritLogSupported OBJECT-TYPE SYNTAX INTEGER { other(1), notSupported(2), supported(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies if this system supports the critical error logging feature." ::= { cpqHeCriticalError 1 } cpqHeCritLogCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the overall condition of the critical error log feature." ::= { cpqHeCriticalError 2 } cpqHeLastCritErrorAbendMsg OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Last Critical Termination message. The message associated with the last critical error of type criticalException(14) or abend(27)." ::= { cpqHeCriticalError 3 } -- **************************************************************************** -- Health MIB Critical Error Table -- =============================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeCriticalError Group (1.3.6.1.4.1.232.6.2.2) -- cpqHeCriticalErrorTable (1.3.6.1.4.1.232.6.2.2.4) -- -- **************************************************************************** cpqHeCriticalErrorTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHeCriticalErrorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of critical error descriptions." ::= { cpqHeCriticalError 4 } cpqHeCriticalErrorEntry OBJECT-TYPE SYNTAX CpqHeCriticalErrorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A critical error description." INDEX { cpqHeCriticalErrorIndex } ::= { cpqHeCriticalErrorTable 1 } CpqHeCriticalErrorEntry ::= SEQUENCE { cpqHeCriticalErrorIndex INTEGER, cpqHeCriticalErrorStatus INTEGER, cpqHeCriticalErrorType INTEGER, cpqHeCriticalErrorTime OCTET STRING, cpqHeCriticalErrorInfo OCTET STRING, cpqHeCriticalErrorDesc DisplayString } cpqHeCriticalErrorIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A number that uniquely specifies this critical error description. The entries will be in order of occurrence with the most recent entry first." ::= { cpqHeCriticalErrorEntry 1 } cpqHeCriticalErrorStatus OBJECT-TYPE SYNTAX INTEGER { uncorrected(1), corrected(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This value specifies if the user has marked this error as corrected. Marking errors as corrected may be performed with the Diagnostics or by a set operation on this variable. Attempting to set this variable to uncorrected(1) will fail." ::= { cpqHeCriticalErrorEntry 2 } cpqHeCriticalErrorType OBJECT-TYPE SYNTAX INTEGER { other(1), empty(2), nonCorrectableMemErr(3), busMasterTimeoutNmi(4), commandBusTimeoutNmi(5), ioCheckNmi(6), refreshOverflowNmi(7), cacheParityNmi(8), processorParityNmi(9), eisaHostMemReadHit(10), processorFailure(11), cautionTemperature(12), postCriticalError(13), criticalException(14), serverManagerIfFail(15), pentiumIperr(16), pentiumAperr(17), pentiumIeerr(18), pentiumApcheck(19), cpuLocalError(20), failsafeTimer(21), softwareNmi(22), asrBaseMemoryParity(23), asrExtendedMemParity(24), asrResetLimit(25), asrMemoryParity(26), abend(27), asrTestEvent(28), asrTimeoutNmi(29), fanFailure(30), upsDetectedLineFail(31), asrDetectedAtBoot(32), redunPowerSupplyFailure(33), pciBusParityError(34), diagnosticError(35), rtcChipBatteryFailure(36), pentiumBerr(37), dcConverterFailure(38), cpuInternalThreshPassed(39) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the type of error." ::= { cpqHeCriticalErrorEntry 3 } cpqHeCriticalErrorTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3)) ACCESS read-only STATUS mandatory DESCRIPTION "The time of the error: hour (first five bits), day of month (next 5 bits), month (next 4 bits), year of the current century (next 7 bits). The last 3 bits are reserved." ::= { cpqHeCriticalErrorEntry 4 } cpqHeCriticalErrorInfo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..4)) ACCESS read-only STATUS mandatory DESCRIPTION "Information about the error." ::= { cpqHeCriticalErrorEntry 5 } cpqHeCriticalErrorDesc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A text description of the critical error." ::= { cpqHeCriticalErrorEntry 6 } -- **************************************************************************** -- Health MIB Correctable Memory Error Group -- ========================================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeCorrectableMemory Group (1.3.6.1.4.1.232.6.2.3) -- -- The cpqHeCorrectableMemory group describes the health correctable memory -- error log. -- -- Implementation of the cpqHeCorrectableMemory group is mandatory for all -- agents that support the Server Health MIB on a system that has the -- correctable memory feature. -- -- **************************************************************************** cpqHeCorrMemLogStatus OBJECT-TYPE SYNTAX INTEGER { other(1), notSupported(2), disabled(3), enabled(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies whether this system is currently tracking correctable memory errors." ::= { cpqHeCorrectableMemory 1 } cpqHeCorrMemLogCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the overall condition of the correctable memory error log feature." ::= { cpqHeCorrectableMemory 2 } cpqHeCorrMemTotalErrs OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS deprecated DESCRIPTION "The number of correctable memory errors that have occurred." ::= { cpqHeCorrectableMemory 3 } -- **************************************************************************** -- Health MIB Correctable Memory Error Table -- ========================================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeCorrectableMemory Group (1.3.6.1.4.1.232.6.2.3) -- cpqHeCorrMemErrTable (1.3.6.1.4.1.232.6.2.3.4) -- -- **************************************************************************** cpqHeCorrMemErrTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHeCorrMemErrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of correctable memory error descriptions." ::= { cpqHeCorrectableMemory 4 } cpqHeCorrMemErrEntry OBJECT-TYPE SYNTAX CpqHeCorrMemErrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A correctable memory error description." INDEX { cpqHeCorrMemErrIndex } ::= { cpqHeCorrMemErrTable 1 } CpqHeCorrMemErrEntry ::= SEQUENCE { cpqHeCorrMemErrIndex INTEGER, cpqHeCorrMemErrCount INTEGER, cpqHeCorrMemErrTime OCTET STRING, cpqHeCorrMemErrDdr OCTET STRING, cpqHeCorrMemErrSyndrome OCTET STRING, cpqHeCorrMemErrDesc DisplayString, cpqHeCorrMemErrHwLocation DisplayString } cpqHeCorrMemErrIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A number that uniquely specifies this correctable memory error description. The entries will be in order of occurrence with the most recent new entry first." ::= { cpqHeCorrMemErrEntry 1 } cpqHeCorrMemErrCount OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The number of times this memory location has had a correctable memory error. The value zero (0) indicates that the user has marked this error as corrected. Marking errors as corrected may be performed with the Diagnostics or with a set operation of 0 on this variable. Any non-zero valued set operation will fail." ::= { cpqHeCorrMemErrEntry 2 } cpqHeCorrMemErrTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3)) ACCESS read-only STATUS mandatory DESCRIPTION "The time of the error: hour (first five bits), day of month (next 5 bits), month (next 4 bits), year of the current century (next 7 bits). The last 3 bits are reserved." ::= { cpqHeCorrMemErrEntry 3 } cpqHeCorrMemErrDdr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..2)) ACCESS read-only STATUS mandatory DESCRIPTION "The data destination register value. This contains information about the memory bank in which the error occurred. The interpretation of this value is dependent on the machine type." ::= { cpqHeCorrMemErrEntry 4 } cpqHeCorrMemErrSyndrome OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..2)) ACCESS read-only STATUS mandatory DESCRIPTION "The memory syndrome value. This contains information about the memory module in which the error occurred. The interpretation of this value is dependant on the machine type." ::= { cpqHeCorrMemErrEntry 5 } cpqHeCorrMemErrDesc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A text description of the correctable memory error." ::= { cpqHeCorrMemErrEntry 6 } cpqHeCorrMemErrHwLocation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS optional DESCRIPTION "A text description of the hardware location, on complex multi SBB hardware only, for the correctable memory error. A NULL string indicates that the hardware location could not be determined or is irrelevant." ::= { cpqHeCorrMemErrEntry 7 } cpqHeCorrMemErrorCntThresh OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The error threshold for Correctable memory errors. When cpqHeCorrMemErrCount is greater than or equal to this value user action is required to replace the failing memory module." ::= { cpqHeCorrectableMemory 5 } -- **************************************************************************** -- Health MIB Automatic Server Recovery (ASR) Group -- ================================================ -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeAsr Group (1.3.6.1.4.1.232.6.2.5) -- -- The cpqHeAsr group describes the Automatic Server Recovery Health -- feature. -- -- Implementation of the cpqHeAsr group is mandatory for all agents that -- support the Server Health MIB on a system that supports the ASR feature. -- -- **************************************************************************** cpqHeAsrStatus OBJECT-TYPE SYNTAX INTEGER { other(1), notAvailable(2), disabled(3), enabled(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The Automatic Server Recovery feature status. If this object is currently other(1) or notAvailable(2) all set operations will fail. Any attempt to set this object to other(1) or notAvailable(2) by a management station will fail. Setting this object to disabled(3) or enabled(4) will disable or enable the ASR feature. Setting this object to disabled(3) will disable the following objects: cpqHeAsrPagerStatus cpqHeAsrDialInStatus cpqHeAsrDialOutStatus" ::= { cpqHeAsr 1 } cpqHeAsrMajorVersion OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The major version number of the Automatic Server Recovery feature hardware." ::= { cpqHeAsr 2 } cpqHeAsrMinorVersion OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The minor version number of the Automatic Server Recovery feature hardware." ::= { cpqHeAsr 3 } cpqHeAsrTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The time-out in minutes for the Automatic Server Recovery feature hardware. If the variable is not supported, a value of -1 will be returned." ::= { cpqHeAsr 4 } cpqHeAsrBaseIo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Automatic Server Recovery feature Base I/O address." ::= { cpqHeAsr 5 } cpqHeAsrPost OBJECT-TYPE SYNTAX INTEGER { other(1), failed(2), ok(3) } ACCESS read-only STATUS deprecated DESCRIPTION "Indicates if the Automatic Server Recovery timer passed the server power-on self test." ::= { cpqHeAsr 6 } cpqHeAsrReset OBJECT-TYPE SYNTAX INTEGER { other(1), manualReset(2), asrReset(3), viewed-asrReset(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates if the previous reset was caused by the ASR timer. An asrReset(3) condition may be changed with a viewed-asrReset(4) set operation. This is only valid if this variable's current value is asrReset(3). Setting this variable to any other value than viewed-asrReset(4) will fail." ::= { cpqHeAsr 7 } cpqHeAsrReboot OBJECT-TYPE SYNTAX INTEGER { other(1), bootOs(2), bootUtilities(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates what software should be started when the server is rebooted by the ASR feature. If this object is currently set to other(1), set operations will fail. This object may not be set to other(1) by a management station. Setting this object to bootOs(2) or bootUtilities(3) will select the software to be started after an ASR reboot." ::= { cpqHeAsr 8 } cpqHeAsrRebootLimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of ASR timer reboots that should cause the server to boot the firmware console and override the standard reboot setting (cpqHeAsrReboot). If this value is 0 then no limit is defined and the standard reboot option will always be used. If the variable is not supported, a value of -1 will be returned." ::= { cpqHeAsr 9 } cpqHeAsrRebootCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of ASR reboots that have occurred on this server since the last manual reboot. Reboot count may be reset with a zero valued set operation on this variable. Setting this value to a non-zero value will fail. If the variable is not supported, a value of -1 will be returned." ::= { cpqHeAsr 10 } cpqHeAsrPagerStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of the ASR pager feature. If the current value of this object is not other(1), it may be set to disabled(2) or enabled(3). Attempting a set operation while the value is other(1) will fail. Attempting to set the value to other(1) will fail. Setting this object to enabled(3) will enable the cpqHeAsrStatus object." ::= { cpqHeAsr 11 } cpqHeAsrPagerNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..60)) ACCESS read-write STATUS mandatory DESCRIPTION "The pager number to be dialed after an ASR reboot." ::= { cpqHeAsr 12 } cpqHeAsrCommPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The communication port to be used by the firmware pager and console. The value zero (0) indicates this setting is undefined. If the current value of this object is zero (0) any attempt to set this object from a management station will fail. Any attempt to set this object to zero (0) by a management station will fail. If the variable is not supported, a value of -1 will be returned." ::= { cpqHeAsr 13 } cpqHeAsrBaudRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The baud rate to be used by the firmware pager and console. The value zero (0) indicates this setting is undefined. If the variable is not supported, a value of -1 will be returned." ::= { cpqHeAsr 14 } cpqHeAsrPagerMessage OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-write STATUS mandatory DESCRIPTION "The 8 character pager message entered by the user." ::= { cpqHeAsr 15 } cpqHeAsrBootFail OBJECT-TYPE SYNTAX INTEGER { other(1), interrupt18(2) } ACCESS read-only STATUS deprecated DESCRIPTION "The action to be taken if an ASR reboot failure occurs." ::= { cpqHeAsr 16 } cpqHeAsrCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the overall condition of the ASR feature." ::= { cpqHeAsr 17 } cpqHeAsrDialInStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of the ASR dial in feature. If the current value of this object is other(1) any attempt to set this object from a management station will fail. Any attempt to set this object to other(1) by a management station will fail. Setting this object to enabled(3) will enable the cpqHeAsrStatus object." ::= { cpqHeAsr 18 } cpqHeAsrDialOutStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of the ASR dial out feature. If the current value of this object is other(1) any attempt to set this object from a management station will fail. Any attempt to set this object to other(1) by a management station will fail. Setting this object to enabled(3) will enable the cpqHeAsrStatus and the cpqHeAsrDialInStatus objects." ::= { cpqHeAsr 19 } cpqHeAsrDialOutNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..60)) ACCESS read-write STATUS mandatory DESCRIPTION "The phone number to be dialed for remote diagnostics if an ASR reset occurs." ::= { cpqHeAsr 20 } cpqHeAsrNetworkAccessStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of the ASR network access feature. If the current value of this object is other(1) any attempt to set this object from a management station will fail. Any attempt to set this object to other(1) by a management station will fail." ::= { cpqHeAsr 21 } cpqHeAsrPollTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The poll time in seconds the ASR watchdog timer is being refreshed periodically." ::= { cpqHeAsr 22 } -- **************************************************************************** -- Health MIB Thermal Group -- ======================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeThermal Group (1.3.6.1.4.1.232.6.2.6) -- -- The cpqHeThermal group describes the status of the temperature and the -- fans that regulate the temperature. -- -- Implementation of the cpqHeThermal group is mandatory for all agents -- that support the Server Health MIB on a system that supports the thermal -- sensing features. -- -- **************************************************************************** cpqHeThermalCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the overall condition of the system's thermal environment." ::= { cpqHeThermal 1 } cpqHeThermalDegradedAction OBJECT-TYPE SYNTAX INTEGER { other(1), continue(2), shutdown(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The action to perform when the thermal condition is degraded. This value will be one of the following: other(1) This feature is not supported by this system or driver. continue(2) The system should be allowed to continue. shutdown(3) The system should be shutdown." ::= { cpqHeThermal 2 } cpqHeThermalTempStatus OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the system's temperature sensors: This value will be one of the following: other(1) Temp sensing is not supported by this system or driver. ok(2) All temp sensors are within normal operating range. degraded(3) A temp sensor is outside of normal operating range. failed(4) A temp sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs." ::= { cpqHeThermal 3 } cpqHeThermalSystemFanStatus OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the fan(s) in the system. This value will be one of the following: other(1) Fan status detection is not supported by this system or driver. ok(2) All fans are operating properly. degraded(3) A non-required fan is not operating properly. failed(4) A required fan is not operating properly. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the failed(4) condition occurs." ::= { cpqHeThermal 4 } cpqHeThermalCpuFanStatus OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the processor fan(s) in the system. This value will be one of the following: other(1) Fan status detection is not supported by this system or driver. ok(2) All fans are operating properly. failed(4) A fan is not operating properly. The system will be shutdown if the failed(4) condition occurs." ::= { cpqHeThermal 5 } -- **************************************************************************** -- Health MIB Thermal Fan Table -- ============================ -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeThermal Group (1.3.6.1.4.1.232.6.2.6) -- cpqHeThermalFanTable (1.3.6.1.4.1.232.6.2.6.6) -- -- **************************************************************************** cpqHeThermalFanTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHeThermalFanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of fan descriptions." ::= { cpqHeThermal 6 } cpqHeThermalFanEntry OBJECT-TYPE SYNTAX CpqHeThermalFanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A fan description." INDEX { cpqHeThermalFanIndex } ::= { cpqHeThermalFanTable 1 } CpqHeThermalFanEntry ::= SEQUENCE { cpqHeThermalFanIndex INTEGER, cpqHeThermalFanRequired INTEGER, cpqHeThermalFanPresent INTEGER, cpqHeThermalFanCpuFan INTEGER, cpqHeThermalFanStatus INTEGER, cpqHeThermalFanHwLocation DisplayString, cpqHeThermalFanCurrentSpeed INTEGER } cpqHeThermalFanIndex OBJECT-TYPE SYNTAX INTEGER (0..8) ACCESS read-only STATUS mandatory DESCRIPTION "A number that uniquely specifies this fan description." ::= { cpqHeThermalFanEntry 1 } cpqHeThermalFanRequired OBJECT-TYPE SYNTAX INTEGER { other(1), nonRequired(2), required(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies if the fan described is required for proper operation of the system." ::= { cpqHeThermalFanEntry 2 } cpqHeThermalFanPresent OBJECT-TYPE SYNTAX INTEGER { other(1), absent(2), present(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies if the fan described is present in the system." ::= { cpqHeThermalFanEntry 3 } cpqHeThermalFanCpuFan OBJECT-TYPE SYNTAX INTEGER { other(1), systemFan(2), cpuFan(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies if the described fan is intended specifically to cool the CPU(s)." ::= { cpqHeThermalFanEntry 4 } cpqHeThermalFanStatus OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies if the fan described is operating properly. This value will be one of the following: other(1) Fan status detection is not supported by this system or driver. ok(2) The fan is operating properly. failed(4) The fan is not operating properly." ::= { cpqHeThermalFanEntry 5 } cpqHeThermalFanHwLocation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS optional DESCRIPTION "A text description of the hardware location, on complex multi SBB hardware only, for the fan. A NULL string indicates that the hardware location could not be determined or is irrelevant." ::= { cpqHeThermalFanEntry 6 } cpqHeThermalFanCurrentSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The current speed of a fan in rpm - revolutions per minute." ::= { cpqHeThermalFanEntry 7 } -- **************************************************************************** -- Health MIB Fault Tolerant Fan Table -- =================================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeThermal Group (1.3.6.1.4.1.232.6.2.6) -- cpqHeFltTolFanTable (1.3.6.1.4.1.232.6.2.6.7) -- -- **************************************************************************** cpqHeFltTolFanTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHeFltTolFanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Fault Tolerant Fan Entries." ::= { cpqHeThermal 7 } cpqHeFltTolFanEntry OBJECT-TYPE SYNTAX CpqHeFltTolFanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A Fault Tolerant Fan Entry." INDEX { cpqHeFltTolFanChassis, cpqHeFltTolFanIndex } ::= { cpqHeFltTolFanTable 1 } CpqHeFltTolFanEntry ::= SEQUENCE { cpqHeFltTolFanChassis INTEGER, cpqHeFltTolFanIndex INTEGER, cpqHeFltTolFanLocale INTEGER, cpqHeFltTolFanPresent INTEGER, cpqHeFltTolFanType INTEGER, cpqHeFltTolFanSpeed INTEGER, cpqHeFltTolFanRedundant INTEGER, cpqHeFltTolFanRedundantPartner INTEGER, cpqHeFltTolFanCondition INTEGER, cpqHeFltTolFanHotPlug INTEGER, cpqHeFltTolFanHwLocation DisplayString, cpqHeFltTolFanCurrentSpeed INTEGER } cpqHeFltTolFanChassis OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The System Chassis number." ::= { cpqHeFltTolFanEntry 1 } cpqHeFltTolFanIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A number that uniquely specifies this fan description." ::= { cpqHeFltTolFanEntry 2 } cpqHeFltTolFanLocale OBJECT-TYPE SYNTAX INTEGER { other(1), unknown(2), system(3), systemBoard(4), ioBoard(5), cpu(6), memory(7), storage(8), removableMedia(9), powerSupply(10), ambient(11), chassis(12), bridgeCard(13), managementBoard(14), backplane(15), networkSlot(16), bladeSlot(17), virtual(18) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the location of the fan in the system." ::= { cpqHeFltTolFanEntry 3 } cpqHeFltTolFanPresent OBJECT-TYPE SYNTAX INTEGER { other(1), absent(2), present(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies if the fan described is present in the system." ::= { cpqHeFltTolFanEntry 4 } cpqHeFltTolFanType OBJECT-TYPE SYNTAX INTEGER { other(1), tachOutput(2), spinDetect(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the type of fan. other(1) The type of fan could not be determined. tachOutput(2) The fan can increase speed for greater cooling. Implies spin detect. spinDetect(3) The fan can detect when the fan stops spinning." ::= { cpqHeFltTolFanEntry 5 } cpqHeFltTolFanSpeed OBJECT-TYPE SYNTAX INTEGER { other(1), normal(2), high(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the speed of the fan. This value will be set if the fan type is tachOutput." ::= { cpqHeFltTolFanEntry 6 } cpqHeFltTolFanRedundant OBJECT-TYPE SYNTAX INTEGER { other(1), notRedundant(2), redundant(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies if the fan is in a redundant configuration." ::= { cpqHeFltTolFanEntry 7 } cpqHeFltTolFanRedundantPartner OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the index of the redundant partner. A value of zero will be used if there is no redundant partner." ::= { cpqHeFltTolFanEntry 8 } cpqHeFltTolFanCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The condition of the fan. This value will be one of the following: other(1) Fan status detection is not supported by this system or driver. ok(2) The fan is operating properly. degraded(3) A redundant fan is not operating properly. failed(4) A non-redundant fan is not operating properly." ::= { cpqHeFltTolFanEntry 9 } cpqHeFltTolFanHotPlug OBJECT-TYPE SYNTAX INTEGER { other(1), nonHotPluggable(2), hotPluggable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This indicates if the fan is capable of being removed and/or inserted while the system is in an operational state. If the value is hotPluggable(3), the fan can be safely removed if and only if the cpqHeFltTolFanRedundant field is in a redundant(3) state. This value will be one of the following: other(1) The state could not be determined. nonHotPluggable(2) The fan is not hot plug capable. hotPluggable(3) The fan is hot plug capable and can be removed if the system is operating in a redundant state. A fan may be added to an empty fan bay." ::= { cpqHeFltTolFanEntry 10 } cpqHeFltTolFanHwLocation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS optional DESCRIPTION "A text description of the hardware location, on complex multi SBB hardware only, for the fan. A NULL string indicates that the hardware location could not be determined or is irrelevant." ::= { cpqHeFltTolFanEntry 11 } cpqHeFltTolFanCurrentSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The current speed of a fan in rpm - revolutions per minute." ::= { cpqHeFltTolFanEntry 12 } -- **************************************************************************** -- Health MIB Temperature Sensor Table -- =================================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeThermal Group (1.3.6.1.4.1.232.6.2.6) -- cpqHeTemperatureTable (1.3.6.1.4.1.232.6.2.6.8) -- -- **************************************************************************** cpqHeTemperatureTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHeTemperatureEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Temperature Sensor Entries." ::= { cpqHeThermal 8 } cpqHeTemperatureEntry OBJECT-TYPE SYNTAX CpqHeTemperatureEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A Temperature Sensor Entry." INDEX { cpqHeTemperatureChassis, cpqHeTemperatureIndex } ::= { cpqHeTemperatureTable 1 } CpqHeTemperatureEntry ::= SEQUENCE { cpqHeTemperatureChassis INTEGER, cpqHeTemperatureIndex INTEGER, cpqHeTemperatureLocale INTEGER, cpqHeTemperatureCelsius INTEGER, cpqHeTemperatureThreshold INTEGER, cpqHeTemperatureCondition INTEGER, cpqHeTemperatureThresholdType INTEGER, cpqHeTemperatureHwLocation DisplayString } cpqHeTemperatureChassis OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The System Chassis number." ::= { cpqHeTemperatureEntry 1 } cpqHeTemperatureIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A number that uniquely specifies this temperature sensor description." ::= { cpqHeTemperatureEntry 2 } cpqHeTemperatureLocale OBJECT-TYPE SYNTAX INTEGER { other(1), unknown(2), system(3), systemBoard(4), ioBoard(5), cpu(6), memory(7), storage(8), removableMedia(9), powerSupply(10), ambient(11), chassis(12), bridgeCard(13) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the location of the temperature sensor present in the system." ::= { cpqHeTemperatureEntry 3 } cpqHeTemperatureCelsius OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the current temperature sensor reading in degrees celsius. If this value cannot be determined by software, then a value of -99 will be returned." ::= { cpqHeTemperatureEntry 4 } cpqHeTemperatureThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This is the shutdown threshold temperature sensor setting in degrees celsius. This is the temperature in which the sensor will be considered to be in a failed state thus causing the system to be shutdown. If this value cannot be determined by software, then a value of -99 will be returned. Only the Ambient zone type allows setting of the threshold temperature." ::= { cpqHeTemperatureEntry 5 } cpqHeTemperatureCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The Temperature sensor condition. This value will be one of the following: other(1) Temperature could not be determined. ok(2) The temperature sensor is within normal operating range. degraded(3) The temperature sensor is outside of normal operating range. failed(4) The temperature sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs." ::= { cpqHeTemperatureEntry 6 } cpqHeTemperatureThresholdType OBJECT-TYPE SYNTAX INTEGER { other(1), blowout(5), caution(9), critical(15), noreaction(16) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the type of this instance of temperature sensor. This value will be one of the following: other(1) Temperature threshold type could not be determined. blowout(5) If a blowout(5) temperature sensor reaches its threshold, the fan or fans in the area of the temperature sensor will increase in speed in an attempt to reduce the temperature before a caution or critical threshold is reached. caution(9) If a caution(9) temperature sensor reaches its threshold, the cpqHeTemperatureCondition will be set to degraded(3) and the system will either continue or shutdown depending on the setting of cpqHeThermalDegradedAction. critical(15) If a critical(15) temperature sensor reaches its threshold, the cpqHeTemperatureCondition will be set to failed(4) and the system will shutdown. noreaction(16) this value will be defined when a threshold value is zero and system will not react on those sensor as those threshold sensors are meant for display purpose only." ::= { cpqHeTemperatureEntry 7 } cpqHeTemperatureHwLocation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS optional DESCRIPTION "A text description of the hardware location, on complex multi SBB hardware only, for the temperature sensor. A NULL string indicates that the hardware location could not be determined or is irrelevant." ::= { cpqHeTemperatureEntry 8 } -- **************************************************************************** -- Health MIB Post Message Group -- ============================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHePostMsg Group (1.3.6.1.4.1.232.6.2.7) -- -- The cpqHePostMsg group contains a table of the non-critical POST -- errors that occurred during the last reboot. -- -- Implementation of the cpqHePostMsg group is mandatory for all agents -- that support the Server Health MIB on a system that supports the POST -- error recording feature. -- -- **************************************************************************** cpqHePostMsgCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the overall condition of the POST error recording feature." ::= { cpqHePostMsg 1 } -- **************************************************************************** -- Health MIB Post Message Table -- ============================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHePostMsg Group (1.3.6.1.4.1.232.6.2.7) -- cpqHePostMsgTable (1.3.6.1.4.1.232.6.2.7.2) -- -- This table may be empty if no errors occurred during POST. -- -- **************************************************************************** cpqHePostMsgTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHePostMsgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of POST error message numbers." ::= { cpqHePostMsg 2 } cpqHePostMsgEntry OBJECT-TYPE SYNTAX CpqHePostMsgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A POST error message number." INDEX { cpqHePostMsgIndex } ::= { cpqHePostMsgTable 1 } CpqHePostMsgEntry ::= SEQUENCE { cpqHePostMsgIndex INTEGER, cpqHePostMsgCode INTEGER, cpqHePostMsgDesc DisplayString } cpqHePostMsgIndex OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "A number that uniquely specifies this POST error description." ::= { cpqHePostMsgEntry 1 } cpqHePostMsgCode OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies POST message number for this error." ::= { cpqHePostMsgEntry 2 } cpqHePostMsgDesc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This contains a text description of the POST error. A string of length zero (0) will be returned if no description is available." ::= { cpqHePostMsgEntry 3 } cpqHePostMsgEv OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) ACCESS read-write STATUS mandatory DESCRIPTION "The EV used to store 8 non-critical POST error codes for use with Quicktest, Utilities, and CIM. Setting this variable with a zero length octet string will clear this variable. All other set operations will fail." ::= { cpqHePostMsg 3 } -- **************************************************************************** -- Health MIB System Utilization Group -- =================================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeSysUtil Group (1.3.6.1.4.1.232.6.2.8) -- -- The cpqHeSysUtil group contains measures of system utilization. -- This group includes long term utilization information like the total -- server up time since originally configured. This group also contains -- current operating utilization information such as the current EISA bus -- utilization. -- -- Implementation of the cpqHeSysUtil group is mandatory for all agents -- that support the Server Health MIB on a system that supports any system -- utilization features. -- -- **************************************************************************** cpqHeSysUtilLifeTime OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The total time (in minutes) the system has been in full operation (while the server health supporting software was running)." ::= { cpqHeSysUtil 1 } cpqHeSysUtilEisaBusMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The EISA bus utilization as a percentage of the theoretical maximum during the last minute. A value of -1 indicates that this feature is not supported on this machine or is not available." ::= { cpqHeSysUtil 2 } cpqHeSysUtilEisaBusFiveMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The EISA bus utilization as a percentage of the theoretical maximum during the last five minutes. A value of -1 indicates that this feature is not supported on this machine or is not available." ::= { cpqHeSysUtil 3 } cpqHeSysUtilEisaBusThirtyMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The EISA bus utilization as a percentage of the theoretical maximum during the last thirty minutes. A value of -1 indicates that this feature is not supported on this machine or is not available." ::= { cpqHeSysUtil 4 } cpqHeSysUtilEisaBusHour OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The EISA bus utilization as a percentage of the theoretical maximum during the last hour. A value of -1 indicates that this feature is not supported on this machine or is not available." ::= { cpqHeSysUtil 5 } -- **************************************************************************** -- Health MIB PCI Utilization Table -- ==================================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeSysUtil Group (1.3.6.1.4.1.232.6.2.8) -- cpqHeSysUtilPciTable (1.3.6.1.4.1.232.6.2.8.6) -- -- -- **************************************************************************** cpqHeSysUtilPciTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHeSysUtilPciEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of PCI utilization numbers for a whole aggregate PCI bus or a specific device on that bus." ::= { cpqHeSysUtil 6 } cpqHeSysUtilPciEntry OBJECT-TYPE SYNTAX CpqHeSysUtilPciEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "PCI utilization entry" INDEX { cpqHeSysUtilPciIndex } ::= { cpqHeSysUtilPciTable 1 } CpqHeSysUtilPciEntry ::= SEQUENCE { cpqHeSysUtilPciIndex INTEGER, cpqHeSysUtilPciBus INTEGER, cpqHeSysUtilPciDevice INTEGER, cpqHeSysUtilPciMin INTEGER, cpqHeSysUtilPciFiveMin INTEGER, cpqHeSysUtilPciThirtyMin INTEGER, cpqHeSysUtilPciHour INTEGER, cpqHeSysUtilPciHwLocation DisplayString } cpqHeSysUtilPciIndex OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "A unique index into each PCI utilization table entry. " ::= { cpqHeSysUtilPciEntry 1 } cpqHeSysUtilPciBus OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The PCI bus number for this set of utilization numbers. " ::= { cpqHeSysUtilPciEntry 2 } cpqHeSysUtilPciDevice OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The PCI device number for this set of utilization numbers. If this value is -1, the utilization reported is for the aggregate of all devices on this PCI bus. " ::= { cpqHeSysUtilPciEntry 3 } cpqHeSysUtilPciMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The utilization as a percentage of the theoretical maximum during the last minute. A value of -1 indicates that the utilization number is not available." ::= { cpqHeSysUtilPciEntry 4 } cpqHeSysUtilPciFiveMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The utilization as a percentage of the theoretical maximum during the last five minutes. A value of -1 indicates that the utilization number is not available." ::= { cpqHeSysUtilPciEntry 5 } cpqHeSysUtilPciThirtyMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The utilization as a percentage of the theoretical maximum during the last thirty minutes. A value of -1 indicates that the utilization number is not available." ::= { cpqHeSysUtilPciEntry 6 } cpqHeSysUtilPciHour OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The utilization as a percentage of the theoretical maximum during the last hour. A value of -1 indicates that the utilization number is not available." ::= { cpqHeSysUtilPciEntry 7 } cpqHeSysUtilPciHwLocation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS optional DESCRIPTION "A text description of the hardware location, on complex multi SBB hardware only, for the PCI drawer. A NULL string indicates that the hardware location could not be determined or is irrelevant." ::= { cpqHeSysUtilPciEntry 8 } -- **************************************************************************** -- Health MIB Fault Tolerant Power Supply Group -- ============================================ -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeFltTolPwrSupply Group (1.3.6.1.4.1.232.6.2.9) -- -- The cpqHeFltTolPwrSupply group contains management information about fault -- tolerant power supplies. -- -- Implementation of the cpqHeFltTolPwrSupply group is mandatory for all -- agents that support the Server Health MIB. -- -- **************************************************************************** cpqHeFltTolPwrSupplyCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the overall condition of the fault tolerant power supply sub-system." ::= { cpqHeFltTolPwrSupply 1 } cpqHeFltTolPwrSupplyStatus OBJECT-TYPE SYNTAX INTEGER { other(1), notSupported(2), notInstalled(3), installed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the status of the fault tolerant power supply." ::= { cpqHeFltTolPwrSupply 2 } -- **************************************************************************** -- Health MIB Fault Tolerant Power Supply Table -- ============================================ -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeFltTolPowerSupply Group (1.3.6.1.4.1.232.6.2.9) -- cpqHeFltTolPowerSupplyTable (1.3.6.1.4.1.232.6.2.9.3) -- -- **************************************************************************** cpqHeFltTolPowerSupplyTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHeFltTolPowerSupplyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Power Supply Entries." ::= { cpqHeFltTolPwrSupply 3 } cpqHeFltTolPowerSupplyEntry OBJECT-TYPE SYNTAX CpqHeFltTolPowerSupplyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A Fault Tolerant Power Supply Entry." INDEX { cpqHeFltTolPowerSupplyChassis, cpqHeFltTolPowerSupplyBay } ::= { cpqHeFltTolPowerSupplyTable 1 } CpqHeFltTolPowerSupplyEntry ::= SEQUENCE { cpqHeFltTolPowerSupplyChassis INTEGER, cpqHeFltTolPowerSupplyBay INTEGER, cpqHeFltTolPowerSupplyPresent INTEGER, cpqHeFltTolPowerSupplyCondition INTEGER, cpqHeFltTolPowerSupplyStatus INTEGER, cpqHeFltTolPowerSupplyMainVoltage INTEGER, cpqHeFltTolPowerSupplyCapacityUsed INTEGER, cpqHeFltTolPowerSupplyCapacityMaximum INTEGER, cpqHeFltTolPowerSupplyRedundant INTEGER, cpqHeFltTolPowerSupplyModel DisplayString, cpqHeFltTolPowerSupplySerialNumber DisplayString, cpqHeFltTolPowerSupplyAutoRev OCTET STRING, cpqHeFltTolPowerSupplyHotPlug INTEGER, cpqHeFltTolPowerSupplyFirmwareRev DisplayString, cpqHeFltTolPowerSupplyHwLocation DisplayString, cpqHeFltTolPowerSupplySparePartNum DisplayString, cpqHeFltTolPowerSupplyRedundantPartner INTEGER, cpqHeFltTolPowerSupplyErrorCondition INTEGER } cpqHeFltTolPowerSupplyChassis OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The system chassis number." ::= { cpqHeFltTolPowerSupplyEntry 1 } cpqHeFltTolPowerSupplyBay OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The bay number to index within this chassis." ::= { cpqHeFltTolPowerSupplyEntry 2 } cpqHeFltTolPowerSupplyPresent OBJECT-TYPE SYNTAX INTEGER { other(1), absent(2), present(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the power supply is present in the chassis." ::= { cpqHeFltTolPowerSupplyEntry 3 } cpqHeFltTolPowerSupplyCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The condition of the power supply. This value will be one of the following: other(1) The status could not be determined or not present. ok(2) The power supply is operating normally. degraded(3) A temperature sensor, fan or other power supply component is outside of normal operating range. failed(4) A power supply component detects a condition that could permanently damage the system." ::= { cpqHeFltTolPowerSupplyEntry 4 } cpqHeFltTolPowerSupplyStatus OBJECT-TYPE SYNTAX INTEGER { noError(1), generalFailure(2), bistFailure(3), fanFailure(4), tempFailure(5), interlockOpen(6), epromFailed(7), vrefFailed(8), dacFailed(9), ramTestFailed(10), voltageChannelFailed(11), orringdiodeFailed(12), brownOut(13), giveupOnStartup(14), nvramInvalid(15), calibrationTableInvalid(16) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the power supply." ::= { cpqHeFltTolPowerSupplyEntry 5 } cpqHeFltTolPowerSupplyMainVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The input main voltage of the power supply in volts." ::= { cpqHeFltTolPowerSupplyEntry 6 } cpqHeFltTolPowerSupplyCapacityUsed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The currently used capacity of the power supply in watts." ::= { cpqHeFltTolPowerSupplyEntry 7 } cpqHeFltTolPowerSupplyCapacityMaximum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum capacity of the power supply in watts." ::= { cpqHeFltTolPowerSupplyEntry 8 } cpqHeFltTolPowerSupplyRedundant OBJECT-TYPE SYNTAX INTEGER { other(1), notRedundant(2), redundant(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The redundancy state of the power supply. This value will be one of the following: other(1) The redundancy state could not be determined. notRedundant(2) The power supply is not operating in a redundant state. redundant(3) The power supply is operating in a redundant state." ::= { cpqHeFltTolPowerSupplyEntry 9 } cpqHeFltTolPowerSupplyModel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "The power supply model name." ::= { cpqHeFltTolPowerSupplyEntry 10 } cpqHeFltTolPowerSupplySerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "The power supply serial number." ::= { cpqHeFltTolPowerSupplyEntry 11 } cpqHeFltTolPowerSupplyAutoRev OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..4)) ACCESS read-only STATUS mandatory DESCRIPTION "The power supply auto revision number." ::= { cpqHeFltTolPowerSupplyEntry 12 } cpqHeFltTolPowerSupplyHotPlug OBJECT-TYPE SYNTAX INTEGER { other(1), nonHotPluggable(2), hotPluggable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This indicates if the power supply is capable of being removed and/or inserted while the system is in an operational state. If the value is hotPluggable(3), the power supply can be safely removed if and only if the cpqHeFltTolPowerSupplyRedundant field is in a redundant(3) state. This value will be one of the following: other(1) The state could not be determined. nonHotPluggable(2) The power supply is not hot plug capable. hotPluggable(3) The power supply is hot plug capable and can be removed if the system is operating in a redundant state. A power supply may be added to an empty power supply bay." ::= { cpqHeFltTolPowerSupplyEntry 13 } cpqHeFltTolPowerSupplyFirmwareRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..24)) ACCESS read-only STATUS mandatory DESCRIPTION "The power supply firmware revision. This field will be left blank if the firmware revision is unknown." ::= { cpqHeFltTolPowerSupplyEntry 14 } cpqHeFltTolPowerSupplyHwLocation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS optional DESCRIPTION "A text description of the hardware location, on complex multi SBB hardware only, for the power supply. A NULL string indicates that the hardware location could not be determined or is irrelevant." ::= { cpqHeFltTolPowerSupplyEntry 15 } cpqHeFltTolPowerSupplySparePartNum OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The power supply part number or spare part number." ::= { cpqHeFltTolPowerSupplyEntry 16 } cpqHeFltTolPowerSupplyRedundantPartner OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the index of the redundant partner. A value of zero will be used if there is no redundant partner." ::= { cpqHeFltTolPowerSupplyEntry 17 } cpqHeFltTolPowerSupplyErrorCondition OBJECT-TYPE SYNTAX INTEGER { noError(1), generalFailure(2), overvoltage(3), overcurrent(4), overtemperature(5), powerinputloss(6), fanfailure(7), vinhighwarning(8), vinlowwarning(9), vouthighwarning(10), voutlowwarning(11), inlettemphighwarning(12), iinternaltemphighwarning(13), vauxhighwarning(14), vauxlowwarning(15) } ACCESS read-only STATUS mandatory DESCRIPTION "The Error condition of the power supply." ::= { cpqHeFltTolPowerSupplyEntry 18 } -- **************************************************************************** -- Health MIB Integrated Remote Console (IRC) Group -- ================================================ -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeIRC Group (1.3.6.1.4.1.232.6.2.10) -- -- The cpqHeIRC group contains management information about the Integrated -- Remote Console ASIC. -- -- Implementation of the cpqHeIRC group is mandatory for all agents that -- support the Server Health MIB. -- -- **************************************************************************** cpqHeIRCStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), notavailable(2), disabled(3), enabled(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the Integrated Remote Console. A value of notavailable will be returned if this system does not contain IRC." ::= { cpqHeIRC 1 } -- **************************************************************************** -- Health MIB System Event Log Group -- ================================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeEventLog Group (1.3.6.1.4.1.232.6.2.11) -- -- The cpqHeEventLog group describes the health system event log. -- -- Implementation of the cpqHeEventLog group is mandatory for all -- agents that support the Server Health MIB. -- -- **************************************************************************** cpqHeEventLogSupported OBJECT-TYPE SYNTAX INTEGER { other(1), notSupported(2), supported(3), clear(4) -- Settable value to clear the log } ACCESS read-write STATUS mandatory DESCRIPTION "This value specifies if this system supports the Integrated Management Log feature. An SNMP set of the value clear(4) will clear the System Event Log of all entries." ::= { cpqHeEventLog 1 } cpqHeEventLogCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the overall condition of the Integrated Management Log feature." ::= { cpqHeEventLog 2 } -- **************************************************************************** -- Health MIB System Event Log Table -- ================================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeEventLog Group (1.3.6.1.4.1.232.6.2.11) -- cpqHeEventLogTable (1.3.6.1.4.1.232.6.2.11.3) -- -- **************************************************************************** cpqHeEventLogTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHeEventLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of System Event Log Entries." ::= { cpqHeEventLog 3 } cpqHeEventLogEntry OBJECT-TYPE SYNTAX CpqHeEventLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A System Event Log Entry." INDEX { cpqHeEventLogEntryNumber } ::= { cpqHeEventLogTable 1 } CpqHeEventLogEntry ::= SEQUENCE { cpqHeEventLogEntryNumber INTEGER, cpqHeEventLogEntrySeverity INTEGER, cpqHeEventLogEntryClass INTEGER, cpqHeEventLogEntryCode INTEGER, cpqHeEventLogEntryCount INTEGER, cpqHeEventLogInitialTime OCTET STRING, cpqHeEventLogUpdateTime OCTET STRING, cpqHeEventLogErrorDesc DisplayString, cpqHeEventLogFreeFormData OCTET STRING } cpqHeEventLogEntryNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A number that uniquely specifies this system event log entry." ::= { cpqHeEventLogEntry 1 } cpqHeEventLogEntrySeverity OBJECT-TYPE SYNTAX INTEGER { informational(2), -- informational with no action required infoWithAlert(3), -- informational but with LCD alert message repaired(6), -- corrective action taken caution(9), -- non-fatal error condition critical(15) -- component failure } ACCESS read-write STATUS mandatory DESCRIPTION "This value specifies the severity of the event log entry. A caution or critical entry can have it's severity lowered by setting this variable to the repaired state." ::= { cpqHeEventLogEntry 2 } cpqHeEventLogEntryClass OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the event log entry class designation." ::= { cpqHeEventLogEntry 3 } cpqHeEventLogEntryCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the event log entry code designation. The meaning of this changes depending on the class." ::= { cpqHeEventLogEntry 4 } cpqHeEventLogEntryCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the event log entry occurrence count. This represents the number of times this event has occurred starting from the initial time until the last modified time." ::= { cpqHeEventLogEntry 5 } cpqHeEventLogInitialTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) ACCESS read-only STATUS mandatory DESCRIPTION "The time stamp when the event log entry was first created. field octets contents range ===== ====== ======== ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 The year field is set with the most significant octet first. A value of 0 in the year indicates an unknown time stamp." ::= { cpqHeEventLogEntry 6 } cpqHeEventLogUpdateTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) ACCESS read-only STATUS mandatory DESCRIPTION "The time stamp when the event log entry was last modified. field octets contents range ===== ====== ======== ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 The year field is set with the most significant octet first. A value of 0 in the year indicates an unknown time stamp." ::= { cpqHeEventLogEntry 7 } cpqHeEventLogErrorDesc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A text description of the event log entry." ::= { cpqHeEventLogEntry 8 } cpqHeEventLogFreeFormData OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) ACCESS read-only STATUS mandatory DESCRIPTION "This is the free form data associated with a particular event." ::= { cpqHeEventLogEntry 9 } -- **************************************************************************** -- Health MIB Management Display Group -- =================================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeMgmtDisplay Group (1.3.6.1.4.1.232.6.2.12) -- -- **************************************************************************** -- The cpqHeMgmtDisplay group maintains information about the Management -- Display device. -- -- Implementation of the cpqHeTrap group is mandatory for agents that -- support the Server Health MIB. cpqHeMgmtDisplayType OBJECT-TYPE SYNTAX INTEGER { other(1), -- Unknown device or could not be determined none(2), -- No Management display device imd4x16(3), -- IMD display (4 lines by 16 chars) ocp1x16(4) -- Digital OCP display (1 line by 16 chars) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the type of Management Display device. If a display device is available on the server, the type will be set accordingly. If no device is present, the value will be set to none(2)." ::= { cpqHeMgmtDisplay 1 } cpqHeMgmtDisplayText OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "The text to be written to the Management display device. If this item is read, it may not accurately reflect what is currently displayed." ::= { cpqHeMgmtDisplay 2 } cpqHeMgmtUID OBJECT-TYPE SYNTAX INTEGER { other(1), -- Unknown device or could not be determined none(2), -- No unit identifier device ledOn(3), -- Unit identifier LED is On ledOff(4), -- Unit identifier LED is Off ledBlinking(5) -- Unit identifier LED is Blinking } ACCESS read-write STATUS mandatory DESCRIPTION "The Unit Identifier LED. This value will be one of the following: other(1) The state of the LED could not be determined. Setting the LED state is not allowed. none(2) The LED is not present. Setting LED state is not allowed. ledOn(3) The LED is present and ON. The LED can be turned Off or Blinking by setting the cpqHeMgmtUID to ledOff(4) or ledBlinking(5) respectively. ledOff(4) The LED is present and OFF. The LED can be turned On or Blinking by setting the cpqHeMgmtUID to ledOn(3) or ledBlinking(5) respectively. ledBlinking(5) The LED is present and is Blinking. The LED can be turned On or Off by setting the cpqHeMgmtUID to ledOn(3) or ledOff(4) respectively" ::= { cpqHeMgmtDisplay 3 } -- **************************************************************************** -- Health MIB Power Converter Group -- ================================ -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHePowerConverter Group (1.3.6.1.4.1.232.6.2.13) -- -- The cpqHePowerConverter group describes the power converter modules -- in the system. -- -- Implementation of the cpqHePowerConverter group is mandatory for all -- agents that support the Server Health MIB. -- -- **************************************************************************** cpqHePowerConverterSupported OBJECT-TYPE SYNTAX INTEGER { other(1), notSupported(2), supported(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies if this system supports reporting power converter module information." ::= { cpqHePowerConverter 1 } cpqHePowerConverterCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the overall condition of the power converters modules in the system." ::= { cpqHePowerConverter 2 } -- **************************************************************************** -- Health MIB Power Converter Table -- ================================ -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHePowerConverter Group (1.3.6.1.4.1.232.6.2.13) -- cpqHePowerConverterTable (1.3.6.1.4.1.232.6.2.13.3) -- -- **************************************************************************** cpqHePowerConverterTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHePowerConverterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Power Converter Module Entries." ::= { cpqHePowerConverter 3 } cpqHePowerConverterEntry OBJECT-TYPE SYNTAX CpqHePowerConverterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A Power Converter Module Entry." INDEX { cpqHePwrConvChassis, cpqHePwrConvIndex } ::= { cpqHePowerConverterTable 1 } CpqHePowerConverterEntry ::= SEQUENCE { cpqHePwrConvChassis INTEGER, cpqHePwrConvIndex INTEGER, cpqHePwrConvPresent INTEGER, cpqHePwrConvSlot INTEGER, cpqHePwrConvSocket INTEGER, cpqHePwrConvRedundant INTEGER, cpqHePwrConvRedundantGroupId INTEGER, cpqHePwrConvCondition INTEGER, cpqHePwrConvHwLocation DisplayString } cpqHePwrConvChassis OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The system chassis number containing the power converter modules." ::= { cpqHePowerConverterEntry 1 } cpqHePwrConvIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Power Converter Module number to index within the chassis." ::= { cpqHePowerConverterEntry 2 } cpqHePwrConvPresent OBJECT-TYPE SYNTAX INTEGER { other(1), absent(2), present(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies if the Power Converter Module described is present in the system." ::= { cpqHePowerConverterEntry 3 } cpqHePwrConvSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Power Converter Module slot number within the chassis." ::= { cpqHePowerConverterEntry 4 } cpqHePwrConvSocket OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Power Converter Module socket number within the slot." ::= { cpqHePowerConverterEntry 5 } cpqHePwrConvRedundant OBJECT-TYPE SYNTAX INTEGER { other(1), nonRedundant(2), redundant(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies if the Power Converter Module is redundant." ::= { cpqHePowerConverterEntry 6 } cpqHePwrConvRedundantGroupId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Power Converter Module group id. A redundant set of power converters will have the same group id." ::= { cpqHePowerConverterEntry 7 } cpqHePwrConvCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The Power Converter Module condition." ::= { cpqHePowerConverterEntry 8 } cpqHePwrConvHwLocation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS optional DESCRIPTION "A text description of the hardware location, on complex multi SBB hardware only, for the power converter. A NULL string indicates that the hardware location could not be determined or is irrelevant." ::= { cpqHePowerConverterEntry 9 } -- **************************************************************************** -- Health MIB Advanced Memory Protection Group (formerly Resilient Memory) -- ======================================================================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeResilientMemory Group (1.3.6.1.4.1.232.6.2.14) -- -- The cpqHeResilientMemory group describes the Advanced Memory Protection -- sub-system in the server. -- -- Implementation of the cpqHeResilientMemory group is mandatory for all -- Server Agents that support the Server Health MIB. -- -- **************************************************************************** cpqHeResilientMemTypeActive OBJECT-TYPE SYNTAX INTEGER { other(1), none(2), onLineSpare(3), mirrored(4), -- deprecated advancedEcc(5), mirroredSingleBoard(6), mirroredDualBoard(7), xor(8), lockStep(9), onLineSpareChannel(10), onLineSpareRank(11), mirroringIntrasocket(12), mirroringIntersocket(13) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the type of Advanced Memory Protection fault tolerance currently active on the system. The following connection states are supported: other(1) The Advanced Memory Protection fault tolerance cannot be determined by the Management Agent. You may need to upgrade your software. none(2) This system is not configured for Advanced Memory Protection fault tolerance or Advanced Memory Protection is not available on this system. onLineSpare(3) This system is configured for Online Spare Advanced Memory Protection. mirrored(4) This system is configured for Mirrored Advanced Memory Protection. advancedECC(5) This system is configured for the Advanced ECC type of Advanced Memory Protection. mirroredSingleBoard(6) This system is configured for Mirrored Advanced Memory Protection within a single memory board. mirroredDualBoard(7) This system is configured for Mirrored Advanced Memory Protection within a dual memory board configuration. The mirrored memory may be swapped with memory on the same memory board or with memory on the second memory board. xor(8) This system is configured for Advanced Memory Protection using the XOR engine. lockStep(9) This system is configured for LockStep type of Advanced Memory Protection. onLineSpareChannel(10) This system is configured for Online Spare Channel Advanced Memory Protection. onLineSpareRank(11) This system is configured for Online Spare Rank Advanced Memory Protection. mirroringIntrasocket(12) This system is configured for Mirrored Intrasocket Advanced Memory Protection between memory of single processor or board. mirroringIntersocket(13) This system is configured for Mirrored Intersocket Advanced Memory Protection between memory of two processors or boards." ::= { cpqHeResilientMemory 1 } cpqHeResilientMemTypeAvailable OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the type of Advanced Memory Protection Fault Tolerance available on the system. This is a collection of flags used to indicate the fault Advanced Memory Protection options available. This integer is a bitmap, with each bit indicating the availability of an option. If the bit is set to 1, the option is available; otherwise it is not. Multiple options are allowed. NOTE: bit 31 is the most significant bit, bit 0 is the least significant. Bit 31-11: RESERVED (0) Bit 10: Mirroring Intersocket Bit 9: Mirroring Intrasocket Bit 8: Online Rank Spare Bit 7: Online Channel Spare Bit 6: LockStep Bit 5: XOR Bit 4: Mirrored Memory with dual memory boards Bit 3: Mirrored Memory within a single memory board Bit 2: Advanced ECC Bit 1: Mirrored (deprecated) Bit 0: Online Spare" ::= { cpqHeResilientMemory 2 } cpqHeResilientMemStatus OBJECT-TYPE SYNTAX INTEGER { other(1), notProtected(2), protected(3), degraded(4), dimmEcc(5), mirrorNoFaults(6), mirrorWithFaults(7), hotSpareNoFaults(8), hotSpareWithFaults(9), xorNoFaults(10), xorWithFaults(11), advancedEcc(12), advancedEccWithFaults(13), lockStep(14), lockStepWithFaults(15) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the current state of the Advanced Memory Protection subsystem. The following states are supported: other(1) The system does not support Advanced Memory Protection or the status cannot be determined by the Management Agent. notProtected(2) This system supports Advanced Memory Protection but the feature is disabled. protected(3) The system is protected by Advanced Memory Protection. degraded(4) The system was protected, but the Advanced Memory Protection feature has been engaged. dimmEcc(5) The system is protected via DIMM ECC only. mirrorNoFaults(6) The system is protected by Advanced Memory Protection in the mirrored mode. No DIMM faults have been detected. mirrorWithFaults(7) The system is protected by Advanced Memory Protection in the mirrored mode. One or more DIMM faults have been detected. hotSpareNoFaults(8) The system is protected by Advanced Memory Protection in the hot spare mode. No DIMM faults have been detected. hotSpareWithFaults(9) The system is protected by Advanced Memory Protection in the hot spare mode. One or more DIMM faults have been detected. xorNoFaults(10) The system is protected by Advanced Memory Protection in the XOR memory mode. No DIMM faults have been detected. xorWithFaults(11) The system is protected by Advanced Memory Protection in the XOR memory mode. One or more DIMM faults have been detected. advancedEcc(12) The system is protected by Advanced Memory Protection in the Advanced ECC mode. advancedEccWithFaults(13) The system is protected by Advanced Memory Protection in the Advanced ECC mode. One or more DIMM faults have been detected. lockStep(14) The system is protected by Advanced Memory Protection in the Lock Step mode. localStepWithFaults(15) The system is protected by Advanced Memory Protection in the Lock Step mode. One or more DIMM faults have been detected." ::= { cpqHeResilientMemory 3 } cpqHeResilientMemCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the current condition of the Advanced Memory Protection subsystem. The following states are supported: other(1) The system does not support fault tolerant memory or the state cannot be determined by the Management Agent. ok(2) This system is operating normally. degraded(3) The system is running in a degraded state because the Advanced Memory Protection subsystem has been engaged." ::= { cpqHeResilientMemory 4 } cpqHeResilientMemHotPlug OBJECT-TYPE SYNTAX INTEGER { other(1), nonHotPluggable(2), hotPluggable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the current condition of the Advanced Memory Protection subsystem. The following states are supported: other(1) The state could not be determined or the system does not support Advanced Memory Protection. nonHotPluggable(2) The memory board or cartridge is not hot plug capable. hotPluggable(3) The memory board or cartridge is hot plug capable and can be removed if the system is operating in a redundant state. A memory board or cartridge may be added to an empty bay." ::= { cpqHeResilientMemory 5 } cpqHeResilientMemOperatingSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the current operating speed of the Advanced Memory Protection subsystem in MHz. If this system does not support Advanced Memory Protection or this value cannot be determined, then a value of 0 will be returned." ::= { cpqHeResilientMemory 6 } cpqHeResilientMemOsMemSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the size of memory as seen by the Operating System in MB (1 MB = 1048576 bytes). If this system does not support Advanced Memory Protection or this value cannot be determined, then a value of 0 will be returned." ::= { cpqHeResilientMemory 7 } cpqHeResilientMemTotalMemSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the total size of memory including memory seen by the Operating System and the memory used for spare, mirrored, or RAID configurations in MB (1 MB = 1048576 bytes). If this system does not support Advanced Memory Protection or this value cannot be determined, then a value of 0 will be returned." ::= { cpqHeResilientMemory 8 } cpqHeResilientMemRivState OBJECT-TYPE SYNTAX INTEGER { other(1), inactive(2), rebuilding(3), initializing(4), verifying(5) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the state of the Rebuild/Initialize/Verify (RIV) engine of the Advanced Memory Protection sub-system. The following states are supported: other(1) The system does not support Advanced Memory Protection or this value cannot be determined, inactive(2) The RIV engine is idle. rebuilding(3) The RIV engine is rebuilding the XOR data. initializing(4) The RIV engine is initializing memory. verifying(5) The RIV engine is verifying memory integrity." ::= { cpqHeResilientMemory 9 } -- **************************************************************************** -- Health MIB Advanced Memory Protection Board Group -- ================================================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeResilientMemory Group (1.3.6.1.4.1.232.6.2.14) -- cpqHeResMemBoardTable (1.3.6.1.4.1.232.6.2.14.10) -- cpqHeResMemBoardEntry (1.3.6.1.4.1.232.6.2.14.10.1) -- -- **************************************************************************** cpqHeResMemBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHeResMemBoardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of memory board or cartridge descriptions in Advanced Memory Protection systems." ::= { cpqHeResilientMemory 10 } cpqHeResMemBoardEntry OBJECT-TYPE SYNTAX CpqHeResMemBoardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A memory board or cartridge description." INDEX { cpqHeResMemBoardSlotIndex } ::= { cpqHeResMemBoardTable 1 } CpqHeResMemBoardEntry ::= SEQUENCE { cpqHeResMemBoardSlotIndex INTEGER, cpqHeResMemBoardOnlineStatus INTEGER, cpqHeResMemBoardErrorStatus INTEGER, cpqHeResMemBoardLocked INTEGER, cpqHeResMemBoardNumSockets INTEGER, cpqHeResMemBoardOsMemSize INTEGER, cpqHeResMemBoardTotalMemSize INTEGER, cpqHeResMemBoardCondition INTEGER, cpqHeResMemBoardHotPlug INTEGER } cpqHeResMemBoardSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the memory board or cartridge is installed." ::= { cpqHeResMemBoardEntry 1 } cpqHeResMemBoardOnlineStatus OBJECT-TYPE SYNTAX INTEGER { other(1), present(2), absent(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The online status of the Advanced Memory Protection board or cartridge. The following status values are supported: other(1) The value is unsupported or could not be determined. present(2) The board or cartridge has memory and is currently online. absent(3) The board or cartridge is missing or offline." ::= { cpqHeResMemBoardEntry 2 } cpqHeResMemBoardErrorStatus OBJECT-TYPE SYNTAX INTEGER { other(1), noError(2), dimmEccError(3), unlockError(4), configError(5), busError(6), powerError(7), advancedEcc(8), onlineSpare(9), mirrored(10), mirroredDimmError(11), memoryRaid(12), raidDimmError(13), lockstep(14), lockstepDimmError(15) } ACCESS read-only STATUS mandatory DESCRIPTION "The error status of the Advanced Memory Protection board or cartridge. The following status values are supported: other(1) The value is unsupported or could not be determined. noError(2) The board or cartridge is configured and operating correctly. dimmEccError(3) The board or cartridge has at least one DIMM ECC error. unlockError(4) The board or cartridge is unlocked when it should not be. Please insure the board of cartridge is locked. configError(5) The board or cartridge has a bad memory configuration. Please insure all memory modules are of the correct type, speed, latency, etc. busError(6) The board or cartridge has a memory bus error. Please insure all memory modules are of the correct type, speed, latency, etc. Also insure the cartridge is inserted properly. powerError(7) The board or cartridge has power error. Please insure all memory modules are of the correct type, speed, latency, etc. Also insure the cartridge is inserted properly. advancedEcc(8), The board or cartridge is configured for advanced Ecc mode. onlineSpare(9), The board or cartridge is configured for Online Spare mode. mirrored(10), The board or cartridge is configured for mirrored mode. mirroredDimmError(11), The board or cartridge has a mirrored Dimm error. memoryRaid(12), The board or cartridge is configured for memory raid mode. raidDimmError(13) The board or cartridge has a raid Dimm error. lockstep(14) The board or cartridge is configured for LockStep. lockstepDimmError(15) The board or cartridge has a lockStep Dimm error." ::= { cpqHeResMemBoardEntry 3 } cpqHeResMemBoardLocked OBJECT-TYPE SYNTAX INTEGER { other(1), unlocked(2), locked(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The locked state of the Advanced Memory Protection board or cartridge. The following status values are supported: other(1) The value is unsupported or could not be determined. If the system does not support hot plugging of the board or cartridge, then this value will be returned. unlocked(2) The board or cartridge is currently unlocked and may be removed. locked(3) The board or cartridge is currently locked and may not be removed." ::= { cpqHeResMemBoardEntry 4 } cpqHeResMemBoardNumSockets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of memory sockets for this memory board or cartridge. If this value could not be determined, or if the board or cartridge has been removed, this value will be -1." ::= { cpqHeResMemBoardEntry 5 } cpqHeResMemBoardOsMemSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the size of memory for this board or cartridge as seen by the Operating System in MB (1 MB = 1048576 bytes). If this system does not support Advanced Memory Protection or this value cannot be determined, then a value of 0 will be returned." ::= { cpqHeResMemBoardEntry 6 } cpqHeResMemBoardTotalMemSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the size of memory for this board or cartridge including memory seen by the Operating System and the memory used for spare, mirrored, or XOR configurations in MB (1 MB = 1048576 bytes). If this system does not support Advanced Memory Protection or this value cannot be determined, then a value of 0 will be returned." ::= { cpqHeResMemBoardEntry 7 } cpqHeResMemBoardCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This provides the current status of the Advanced Memory Protection memory board or cartridge. The following status values are supported: other(1): The condition of this memory board or cartridge could not be determined. ok(2): The memory board or cartridge is operating normally. degraded(3): The memory board or cartridge is in an error state. Check for correct memory installation and that the board has been inserted properly." ::= { cpqHeResMemBoardEntry 8 } cpqHeResMemBoardHotPlug OBJECT-TYPE SYNTAX INTEGER { other(1), nonHotPluggable(2), hotPluggable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This indicates if the memory board is capable of being removed and/or inserted while the system is in an operational state. The following states are supported: other(1) The state could not be determined or the system does not support Advanced Memory Protection. nonHotPluggable(2) The memory board or cartridge is not hot plug capable. hotPluggable(3) The memory board or cartridge is hot plug capable and can be removed if the system is operating in a redundant state. A memory board or cartridge may be added to an empty bay." ::= { cpqHeResMemBoardEntry 9 } -- **************************************************************************** -- Health MIB Advanced Memory Protection Memory Module Group -- ========================================================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeResilientMemory Group (1.3.6.1.4.1.232.6.2.14) -- cpqHeResMemModuleTable (1.3.6.1.4.1.232.6.2.14.11) -- cpqHeResMemModuleEntry (1.3.6.1.4.1.232.6.2.14.11.1) -- -- **************************************************************************** cpqHeResMemModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHeResMemModuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of memory module descriptions." ::= { cpqHeResilientMemory 11 } cpqHeResMemModuleEntry OBJECT-TYPE SYNTAX CpqHeResMemModuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A memory module description." INDEX { cpqHeResMemBoardIndex, cpqHeResMemModuleIndex } ::= { cpqHeResMemModuleTable 1 } CpqHeResMemModuleEntry ::= SEQUENCE { cpqHeResMemBoardIndex INTEGER, cpqHeResMemModuleIndex INTEGER, cpqHeResMemModuleSparePartNo DisplayString, cpqHeResMemModuleStatus INTEGER, cpqHeResMemModuleCondition INTEGER, cpqHeResMemModuleSpd OCTET STRING } cpqHeResMemBoardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the memory board or cartridge is installed. A value of 0 indicates memory installed directly on the system board." ::= { cpqHeResMemModuleEntry 1 } cpqHeResMemModuleIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The memory module number." ::= { cpqHeResMemModuleEntry 2 } cpqHeResMemModuleSparePartNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "The memory module's manufacturer part number. This field will be a null (size 0) string if the manufacturer part number is not available." ::= { cpqHeResMemModuleEntry 3 } cpqHeResMemModuleStatus OBJECT-TYPE SYNTAX INTEGER { other(1), notPresent(2), present(3), good(4), add(5), upgrade(6), missing(7), doesNotMatch(8), notSupported(9), badConfig(10), degraded(11) } ACCESS read-only STATUS mandatory DESCRIPTION "This provides the current status of the correctable memory errors for this memory module. The following status values are supported: other(1): The status is unknown or could not be determined. notPresent(2): The memory module is not present or is un-initialized. present(3): The memory module is present but not in use. good(4): The memory module is present and in use. The corrected error threshold has not been exceeded. add(5): The memory module has been added, but is not yet in use. upgraded(6): The memory module has been upgraded, but the memory is not yet in use. missing(7): An expected memory module is missing. doesNotMatch(8): The memory module does not match the other memory modules within the bank. notSupported(9): The memory module is not supported. badConfig(10): The memory module violates the add/upgrade configuration rules. degraded(11): The memory module's correctable error count has exceeded threshold." ::= { cpqHeResMemModuleEntry 4 } cpqHeResMemModuleCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This provides the current status of the correctable memory errors for this memory module. The following status values are supported: other(1): ECC is not supported on this memory module or the condition could not be determined. ok(2): The memory module is operating normally. degraded(3): The memory module is correctable error count has exceeded threshold or a configuration error has been detected." ::= { cpqHeResMemModuleEntry 5 } cpqHeResMemModuleSpd OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) ACCESS read-only STATUS mandatory DESCRIPTION "This is the raw Serial Presence Detect information contained in the memory module. If the SPD information is not available, this item will be empty." ::= { cpqHeResMemModuleEntry 6 } -- **************************************************************************** -- Health MIB Advanced Memory Protection Board Group -- ================================================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeResilientMemory Group (1.3.6.1.4.1.232.6.2.14) -- cpqHeResMem2BoardTable (1.3.6.1.4.1.232.6.2.14.12) -- cpqHeResMem2BoardEntry (1.3.6.1.4.1.232.6.2.14.12.1) -- -- **************************************************************************** cpqHeResMem2BoardTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHeResMem2BoardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of memory board or cartridge descriptions in Advanced Memory Protection systems." ::= { cpqHeResilientMemory 12 } cpqHeResMem2BoardEntry OBJECT-TYPE SYNTAX CpqHeResMem2BoardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A memory board or cartridge or CPU based Memory Board description." INDEX { cpqHeResMem2BoardIndex } ::= { cpqHeResMem2BoardTable 1 } CpqHeResMem2BoardEntry ::= SEQUENCE { cpqHeResMem2BoardIndex INTEGER, cpqHeResMem2BoardSlotNum INTEGER, cpqHeResMem2BoardCpuNum INTEGER, cpqHeResMem2BoardRiserNum INTEGER, cpqHeResMem2BoardOnlineStatus INTEGER, cpqHeResMem2BoardErrorStatus INTEGER, cpqHeResMem2BoardLocked INTEGER, cpqHeResMem2BoardNumSockets INTEGER, cpqHeResMem2BoardOsMemSize INTEGER, cpqHeResMem2BoardTotalMemSize INTEGER, cpqHeResMem2BoardCondition INTEGER, cpqHeResMem2BoardHotPlug INTEGER, cpqHeResMem2BoardOperatingFrequency INTEGER, cpqHeResMem2BoardOperatingVoltage INTEGER } cpqHeResMem2BoardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This will represent the unique memory board or cartridge or riser." ::= { cpqHeResMem2BoardEntry 1 } cpqHeResMem2BoardSlotNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the memory board or cartridge is installed." ::= { cpqHeResMem2BoardEntry 2 } cpqHeResMem2BoardCpuNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Processor Number to which the memory Riser belongs. Value 0 means memory is not CPU based." ::= { cpqHeResMem2BoardEntry 3 } cpqHeResMem2BoardRiserNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Riser Number on the Processor." ::= { cpqHeResMem2BoardEntry 4 } cpqHeResMem2BoardOnlineStatus OBJECT-TYPE SYNTAX INTEGER { other(1), present(2), absent(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The online status of the Advanced Memory Protection board or cartridge or riser. The following status values are supported: other(1) The value is unsupported or could not be determined. present(2) The board or cartridge or riser has memory and is currently online. absent(3) The board or cartridge or riser is missing or offline." ::= { cpqHeResMem2BoardEntry 5 } cpqHeResMem2BoardErrorStatus OBJECT-TYPE SYNTAX INTEGER { other(1), noError(2), dimmEccError(3), unlockError(4), configError(5), busError(6), powerError(7), advancedEcc(8), onlineSpare(9), mirrored(10), mirroredDimmError(11), memoryRaid(12), raidDimmError(13), lockStep(14), lockStepError(15) } ACCESS read-only STATUS mandatory DESCRIPTION "The error status of the Advanced Memory Protection board or Cartridge or riser. The following status values are supported: other(1) The value is unsupported or could not be determined. noError(2) The board or cartridge or riser is configured and operating correctly. dimmEccError(3) The board or cartridge or riser has at least one DIMM ECC error. unlockError(4) The board or cartridge or riser is unlocked when it should not be. Please insure the board of cartridge is locked. configError(5) The board or cartridge or riser has a bad memory configuration. Please insure all memory modules are of the correct type, speed, latency, etc. busError(6) The board or cartridge or riser has a memory bus error. Please insure all memory modules are of the correct type, speed, latency, etc. Also insure the cartridge is inserted properly. powerError(7) The board or cartridge or riser has power error. Please insure all memory modules are of the correct type, speed, latency, etc. Also insure the cartridge is inserted properly. advancedEcc(8), The board or cartridge or riser is configured for advanced Ecc mode. onlineSpare(9), The board or cartridge or riser is configured for Online Spare mode. mirrored(10), The board or cartridge or riser is configured for mirrored mode. mirroredDimmError(11), The board or cartridge or riser has a mirrored Dimm error. memoryRaid(12), The board or cartridge or riser is configured for memory raid mode. raidDimmError(13) The board or cartridge or riser has a raid Dimm error. lockStep(14), The board or cartridge or riser is configured for lockStep mode. lockStepError(15) The board or cartridge or riser has a lockStep Dimm error." ::= { cpqHeResMem2BoardEntry 6 } cpqHeResMem2BoardLocked OBJECT-TYPE SYNTAX INTEGER { other(1), unlocked(2), locked(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The locked state of the Advanced Memory Protection board or Cartridge or riser. The following status values are supported: other(1) The value is unsupported or could not be determined. If the system does not support hot plugging of the board or cartridge or riser, then this value will be returned. unlocked(2) The board or cartridge or riser is currently unlocked and may be removed. locked(3) The board or cartridge or riser is currently locked and may not be removed." ::= { cpqHeResMem2BoardEntry 7 } cpqHeResMem2BoardNumSockets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of memory sockets for this memory board or Cartridge or riser. If this value could not be determined, or if the board or Cartridge or riser has been removed, this value will be -1." ::= { cpqHeResMem2BoardEntry 8 } cpqHeResMem2BoardOsMemSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the size of memory for this board or cartridge or riser as seen by the Operating System in MB (1 MB = 1048576 bytes). If this system does not support Advanced Memory Protection or this value cannot be determined, then a value of 0 will be returned." ::= { cpqHeResMem2BoardEntry 9 } cpqHeResMem2BoardTotalMemSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the size of memory for this board or Cartridge or riser including memory seen by the Operating System and the memory used for spare, mirrored, or XOR configurations in MB (1 MB = 1048576 bytes). If this system does not support Advanced Memory Protection or this value cannot be determined, then a value of 0 will be returned." ::= { cpqHeResMem2BoardEntry 10 } cpqHeResMem2BoardCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This provides the current status of the Advanced Memory Protection memory board or cartridge or riser. The following status values are supported: other(1): The condition of this memory board or cartridge or riser could not be determined. ok(2): The memory board or cartridge or riser is operating normally. degraded(3): The memory board or cartridge or riser is in an error state. Check for correct memory installation and that the board has been inserted properly." ::= { cpqHeResMem2BoardEntry 11 } cpqHeResMem2BoardHotPlug OBJECT-TYPE SYNTAX INTEGER { other(1), nonHotPluggable(2), hotPluggable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This indicates if the memory board is capable of being removed and/or inserted while the system is in an operational state. The following states are supported: other(1) The state could not be determined or the system does not support Advanced Memory Protection. nonHotPluggable(2) The memory board or cartridge or riser is not hot plug capable. hotPluggable(3) The memory board or cartridge or riser is hot plug capable and can be removed if the system is operating in a redundant state. A memory board or cartridge or riser may be added to an empty bay." ::= { cpqHeResMem2BoardEntry 12} cpqHeResMem2BoardOperatingFrequency OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the operational memory frequency for this board or Cartridge or riser in MHz." ::= { cpqHeResMem2BoardEntry 13 } cpqHeResMem2BoardOperatingVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the operational memory voltage for this board or Cartridge or riser in millivolts." ::= { cpqHeResMem2BoardEntry 14 } -- **************************************************************************** -- Health MIB Advanced Memory Protection Memory Module Group -- ========================================================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHeResilientMemory Group (1.3.6.1.4.1.232.6.2.14) -- cpqHeResMem2ModuleTable (1.3.6.1.4.1.232.6.2.14.13) -- cpqHeResMem2ModuleEntry (1.3.6.1.4.1.232.6.2.14.13.1) -- -- **************************************************************************** cpqHeResMem2ModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHeResMem2ModuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of memory module descriptions." ::= { cpqHeResilientMemory 13 } cpqHeResMem2ModuleEntry OBJECT-TYPE SYNTAX CpqHeResMem2ModuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A memory module description." INDEX { cpqHeResMem2Module } ::= { cpqHeResMem2ModuleTable 1 } CpqHeResMem2ModuleEntry ::= SEQUENCE { cpqHeResMem2Module INTEGER, cpqHeResMem2BoardNum INTEGER, cpqHeResMem2CpuNum INTEGER, cpqHeResMem2RiserNum INTEGER, cpqHeResMem2ModuleNum INTEGER, cpqHeResMem2ModuleSize INTEGER, cpqHeResMem2ModuleType INTEGER, cpqHeResMem2ModuleTechnology INTEGER, cpqHeResMem2ModuleManufacturer DisplayString, cpqHeResMem2ModulePartNo DisplayString, cpqHeResMem2ModuleDate OCTET STRING, cpqHeResMem2ModuleSerialNo DisplayString, cpqHeResMem2ModuleHwLocation DisplayString, cpqHeResMem2ModuleFrequency INTEGER, cpqHeResMem2ModuleCellTablePtr INTEGER, cpqHeResMem2ModuleCellStatus INTEGER, cpqHeResMem2ModulePartNoMfgr DisplayString, cpqHeResMem2ModuleSerialNoMfgr DisplayString, cpqHeResMem2ModuleStatus INTEGER, cpqHeResMem2ModuleCondition INTEGER, cpqHeResMem2ModuleSpd OCTET STRING, cpqHeResMem2ModuleSmartMemory INTEGER, cpqHeResMem2ModuleMinVoltage INTEGER, cpqHeResMem2ModuleRanks INTEGER } cpqHeResMem2Module OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This will represent the unique memory DIMM on memory board or cartridge or riser. " ::= { cpqHeResMem2ModuleEntry 1 } cpqHeResMem2BoardNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the memory board or cartridge is installed. A value of 0 indicates memory installed directly on the system board." ::= { cpqHeResMem2ModuleEntry 2 } cpqHeResMem2CpuNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The memory module CPU number. Value 0 means memory is not Processor based." ::= { cpqHeResMem2ModuleEntry 3 } cpqHeResMem2RiserNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The memory module rasier number." ::= { cpqHeResMem2ModuleEntry 4 } cpqHeResMem2ModuleNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The memory module number." ::= { cpqHeResMem2ModuleEntry 5 } cpqHeResMem2ModuleSize OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Module memory size in kilobytes. A kilobyte of memory is defined as 1024 bytes. A size of 0 indicates the module is not present." ::= { cpqHeResMem2ModuleEntry 6 } cpqHeResMem2ModuleType OBJECT-TYPE SYNTAX INTEGER { other(1), board(2), cpqSingleWidthModule(3), cpqDoubleWidthModule(4), simm(5), pcmcia(6), compaq-specific(7), dimm(8), smallOutlineDimm(9), rimm(10), srimm(11), fb-dimm(12), dimmddr(13), dimmddr2(14), dimmddr3(15), dimmfbd2(16), fb-dimmddr2(17), fb-dimmddr3(18) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of memory module installed. The value other(1) will be given if the type is not known. The value board(2) will be given if the memory module is permanently mounted (not modular) on a system board or memory expansion board." ::= { cpqHeResMem2ModuleEntry 7 } cpqHeResMem2ModuleTechnology OBJECT-TYPE SYNTAX INTEGER { other(1), fastPageMode(2), edoPageMode(3), burstEdoPageMode(4), synchronous(5), rdram(6), rdimm(7), udimm(8), lrdimm(9) } ACCESS read-only STATUS mandatory DESCRIPTION "Technology type of memory module installed. The value other(1) will be given if the technology is not known." ::= { cpqHeResMem2ModuleEntry 8 } cpqHeResMem2ModuleManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The memory module's manufacturer name. This field will be a null (size 0) string if the manufacturer name is not available." ::= { cpqHeResMem2ModuleEntry 9 } cpqHeResMem2ModulePartNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The memory module's manufacturer part number. This field will be a null (size 0) string if the manufacturer part number is not available." ::= { cpqHeResMem2ModuleEntry 10 } cpqHeResMem2ModuleDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (7)) ACCESS read-only STATUS mandatory DESCRIPTION "The memory module date of manufacture. field octets contents range ===== ====== ====================== ======== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the date of manufacture is not available. The hour, minute, and second fields will always be set to 0." ::= { cpqHeResMem2ModuleEntry 11 } cpqHeResMem2ModuleSerialNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "The memory module's serial number. This field will be a null (size 0) string if the serial number is not available." ::= { cpqHeResMem2ModuleEntry 12 } cpqHeResMem2ModuleHwLocation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS optional DESCRIPTION "A text description of the hardware location, on complex multi SBB hardware only, for the memory module. A NULL string indicates that the hardware location could not be determined or is irrelevant." ::= { cpqHeResMem2ModuleEntry 13 } cpqHeResMem2ModuleFrequency OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The memory module maximum frequency in MHz. The value zero (0) will be given if the module frequency cannot be determined." ::= { cpqHeResMem2ModuleEntry 14 } cpqHeResMem2ModuleCellTablePtr OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-only STATUS optional DESCRIPTION "Index for the cell in cpqSeCellTable where the memory board is installed." ::= { cpqHeResMem2ModuleEntry 15 } cpqHeResMem2ModuleCellStatus OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), deconfigured(3) } ACCESS read-only STATUS optional DESCRIPTION "This provides the current status for this memory module. The following status values are supported: other(1): The memory module status is not available ok(2): The memory module is active deconfigured(3): The memory module is not ready" ::= { cpqHeResMem2ModuleEntry 16 } cpqHeResMem2ModulePartNoMfgr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS optional DESCRIPTION "The memory module's manufacturer's part number. This field will be a null (size 0) string if the manufacturer part number is not available." ::= { cpqHeResMem2ModuleEntry 17 } cpqHeResMem2ModuleSerialNoMfgr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS optional DESCRIPTION "The memory module's manufacturer's serial number. This field will be a null (size 0) string if the manufacturer serial number is not available." ::= { cpqHeResMem2ModuleEntry 18 } cpqHeResMem2ModuleStatus OBJECT-TYPE SYNTAX INTEGER { other(1), notPresent(2), present(3), good(4), add(5), upgrade(6), missing(7), doesNotMatch(8), notSupported(9), badConfig(10), degraded(11), spare(12), partial(13) } ACCESS read-only STATUS mandatory DESCRIPTION "This provides the current status of the correctable memory errors for this memory module. The following status values are supported: other(1): The status is unknown or could not be determined. notPresent(2): The memory module is not present or is un-initialized. present(3): The memory module is present but not in use. good(4): The memory module is present and in use. The corrected error threshold has not been exceeded. add(5): The memory module has been added, but is not yet in use. upgraded(6): The memory module has been upgraded, but the memory is not yet in use. missing(7): An expected memory module is missing. doesNotMatch(8): The memory module does not match the other memory modules within the bank. notSupported(9): The memory module is not supported. badConfig(10): The memory module violates the add/upgrade configuration rules. degraded(11): The memory module's correctable error count has exceeded threshold. spare(12): The memory module is configured as a spare. partial(13): The memory module is present and is partially in use." ::= { cpqHeResMem2ModuleEntry 19 } cpqHeResMem2ModuleCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), degradedModuleIndexUnknown(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This provides the current status of the correctable memory errors for this memory module. The following status values are supported: other(1): ECC is not supported on this memory module or the condition could not be determined. ok(2): The memory module is operating normally. degraded(3): The memory module is correctable error count has exceeded threshold or a configuration error has been detected. degradedModuleIndexUnknown(4): The correctable error count has exceeded threshold. The module number not available." ::= { cpqHeResMem2ModuleEntry 20 } cpqHeResMem2ModuleSpd OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) ACCESS read-only STATUS mandatory DESCRIPTION "This is the raw Serial Presence Detect information contained in the memory module. If the SPD information is not available, this item will be empty." ::= { cpqHeResMem2ModuleEntry 21 } cpqHeResMem2ModuleSmartMemory OBJECT-TYPE SYNTAX INTEGER { other(1), notHPSmartMemory(2), isHPSmartMemory(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This indicates whether the DIMM slot is populated with an HP Smart Memory DIMM. The following values are supported: other(1): HP SmartMemory not supported in this device. notHPSmartMemory(2): HP SmartMemory is NOT installed in DIMM slot (includes the case where the DIMM slot is not populated). isHPSmartMemory(3): HP SmartMemory is installed in DIMM slot." ::= { cpqHeResMem2ModuleEntry 22 } cpqHeResMem2ModuleMinVoltage OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This provides the minimum voltage needed for the module to operate, in millivolts." ::= { cpqHeResMem2ModuleEntry 23 } cpqHeResMem2ModuleRanks OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This provides the number of physical ranks on the module." ::= { cpqHeResMem2ModuleEntry 24 } -- **************************************************************************** -- Health MIB Power Meter Group -- ======================================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeComponent Group (1.3.6.1.4.1.232.6.2) -- cpqHePowerMeter Group (1.3.6.1.4.1.232.6.2.15) -- -- The cpqHePowerMeter group describes the Server's power consumption read -- -- -- Implementation of the cpqHePowerMeter group is mandatory for all -- platform that support Power Meter. -- -- **************************************************************************** cpqHePowerMeterSupport OBJECT-TYPE SYNTAX INTEGER { other(1), supported(2), unsupported(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies whether Power Meter is supported by this Server . The following values are supported: other(1) Could not read the Power Meter status. supported(2) This system support Power Meter. unsupported(3) This system does not support Power Meter." ::= { cpqHePowerMeter 1} cpqHePowerMeterStatus OBJECT-TYPE SYNTAX INTEGER { other(1), present(2), absent(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies whether Power Meter reading is supported by this Server . The following values are supported: other(1) Could not read the Power Meter status. present(2) The Power Meter data is available. absent(3) The Power Meter data is not available at this time." ::= { cpqHePowerMeter 2} cpqHePowerMeterCurrReading OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " This is the current Power Meter reading in Watts. This value shows the most recent power reading if available. On systems without Power Meter support, this value will be -1." ::= { cpqHePowerMeter 3 } cpqHePowerMeterPrevReading OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " This is the previous Power Meter reading in Watts. This value shows previous power reading if available. On systems without Power Meter support, this value will be -1." ::= { cpqHePowerMeter 4 } -- **************************************************************************** -- HealthMIB Trap Group -- ===================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeTrap Group (1.3.6.1.4.1.232.6.3) (deprecated) -- -- The cpqHeTrap group maintains information about the number of traps -- issued from the health enterprise. The trap group also maintains a table -- of the last several traps issued. This table is intended to give a -- management application some recent status information immediately upon -- accessing the agent. -- -- Implementation of the cpqHeTrap group is optional for agents that -- support the Server Health MIB. -- -- **************************************************************************** cpqHeTrapPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS deprecated DESCRIPTION "The total number of SNMP trap packets issued by the Server Health agent." ::= { cpqHeTrap 1 } cpqHeTrapLogMaxSize OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS deprecated DESCRIPTION "The maximum number of entries that will currently be kept in the trap log. If the maximum size has been reached and a new trap occurs the oldest trap will be removed." ::= { cpqHeTrap 2 } -- **************************************************************************** -- Health MIB Trap Log Table -- ========================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqHealth Group (1.3.6.1.4.1.232.6) -- cpqHeTrap Group (1.3.6.1.4.1.232.6.3) -- cpqHeTrapLogTable (1.3.6.1.4.1.232.6.3.3) (deprecated) -- -- **************************************************************************** cpqHeTrapLogTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqHeTrapLogEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "An ordered list of trap log entries (conceptually a queue). The trap log entries will be kept in the order in which they were generated with the most recent trap at index 1 and the oldest trap entry at index trapLogMaxSize. If the maximum number of entries has been reached and a new trap occurs the oldest trap will be removed when the new trap is added so the trapMaxLogSize is not exceeded." ::= { cpqHeTrap 3 } cpqHeTrapLogEntry OBJECT-TYPE SYNTAX CpqHeTrapLogEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "A description of a trap event." INDEX { cpqHeTrapLogIndex } ::= { cpqHeTrapLogTable 1 } CpqHeTrapLogEntry ::= SEQUENCE { cpqHeTrapLogIndex INTEGER, cpqHeTrapType INTEGER, cpqHeTrapTime OCTET STRING } cpqHeTrapLogIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS deprecated DESCRIPTION "The value of this object uniquely identifies this trapLogEntry at this time. The most recent trap will have an index of 1 and the oldest trap will have an index of trapLogMaxSize. Because of the queue-like nature of the trapLog this particular trap event's index will change as new traps are issued." ::= { cpqHeTrapLogEntry 1 } cpqHeTrapType OBJECT-TYPE SYNTAX INTEGER { cpqHeCorrectableMemoryError(1), cpqHeCorrectableMemoryLogDisabled(2), cpqHe2CorrectableMemoryError(6001), cpqHe2CorrectableMemoryLogDisabled(6002), cpqHeThermalTempFailed(6003), cpqHeThermalTempDegraded(6004), cpqHeThermalTempOk(6005), cpqHeThermalSystemFanFailed(6006), cpqHeThermalSystemFanDegraded(6007), cpqHeThermalSystemFanOk(6008), cpqHeThermalCpuFanFailed(6009), cpqHeThermalCpuFanOk(6010), cpqHeAsrConfirmation(6011), cpqHeThermalConfirmation(6012), cpqHePostError(6013) } ACCESS read-only STATUS deprecated DESCRIPTION "The type of the trap event this entry describes. This number refers to an entry in a list of traps enumerating the possible traps the Server Health agent may issue." ::= { cpqHeTrapLogEntry 2 } cpqHeTrapTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..6)) ACCESS read-only STATUS deprecated DESCRIPTION "The time of the trap event that this entry describes. The time is given in year (first octet), month, day of month, hour, minute, second (last octet) order. The octets are in Binary Coded Decimal (BCD)." ::= { cpqHeTrapLogEntry 3 } -- **************************************************************************** -- Health MIB Trap Definitions -- =========================== -- -- The SNMP trap messages must not be bigger than 484 octets (bytes). -- -- Trap support in an SNMP agent implementation is optional. An SNMP -- agent implementation may support all, some, or none of the traps. -- If traps are supported, The user should be provided with the option of -- disabling traps. -- ************************************************************************** cpqHeCorrectableMemoryError TRAP-TYPE ENTERPRISE cpqHealth VARIABLES { cpqHeCorrMemTotalErrs } DESCRIPTION "A correctable memory error occurred. The error has been corrected. The current number of correctable memory errors is reported in the variable cpqHeCorrMemTotalErrs." --#TYPE "Correctable Memory Error Occurred (1)" --#SUMMARY "Total correctable errors = %d." --#ARGUMENTS {0} --#SEVERITY MINOR --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 1 cpqHeCorrectableMemoryLogDisabled TRAP-TYPE ENTERPRISE cpqHealth VARIABLES { cpqHeCorrMemLogStatus } DESCRIPTION "Correctable memory error tracking disabled. The frequency of errors is so high that the error tracking logic has been temporarily disabled. The cpqHeCorrMemLogStatus variable indicated the current tracking status." --#TYPE "Memory Error Tracking Disabled (2)" --#SUMMARY "Too many memory errors - tracking now disabled." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED ::= 2 -- Trap definitions for Insight Manager version 2.00 and greater -- use the Compaq Enterprise (232) and have unique trap numbers between all -- of the MIBs. cpqHe2CorrectableMemoryError TRAP-TYPE ENTERPRISE compaq VARIABLES { cpqHeCorrMemTotalErrs } DESCRIPTION "A correctable memory error occurred. The error has been corrected. The current number of correctable memory errors is reported in the variable cpqHeCorrMemTotalErrs." --#TYPE "Correctable Memory Error Occurred (6001)" --#SUMMARY "Total correctable errors = %d." --#ARGUMENTS {0} --#SEVERITY MINOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 6001 cpqHe2CorrectableMemoryLogDisabled TRAP-TYPE ENTERPRISE compaq VARIABLES { cpqHeCorrMemLogStatus } DESCRIPTION "Correctable memory error tracking disabled. The frequency of errors is so high that the error tracking logic has been temporarily disabled. The cpqHeCorrMemLogStatus variable indicated the current tracking status." --#TYPE "Memory Error Tracking Disabled (6002)" --#SUMMARY "Too many memory errors - tracking now disabled." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED ::= 6002 cpqHeThermalTempFailed TRAP-TYPE ENTERPRISE compaq DESCRIPTION "The temperature status has been set to failed. The system will be shutdown due to this thermal condition." --#TYPE "Thermal Failure (6003)" --#SUMMARY "System will be shutdown due to this thermal condition." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED ::= 6003 cpqHeThermalTempDegraded TRAP-TYPE ENTERPRISE compaq VARIABLES { cpqHeThermalDegradedAction } DESCRIPTION "The temperature status has been set to degraded. The server's temperature is outside of the normal operating range. The server will be shutdown if the cpqHeThermalDegradedAction variable is set to shutdown(3)." --#TYPE "Thermal Status Degraded (6004)" --#SUMMARY "Temperature out of range. Shutdown may occur." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED ::= 6004 cpqHeThermalTempOk TRAP-TYPE ENTERPRISE compaq DESCRIPTION "The temperature status has been set to ok. The server's temperature has returned to the normal operating range." --#TYPE "Temperature OK (6005)" --#SUMMARY "Temperature has returned to normal range." --#ARGUMENTS {} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 6005 cpqHeThermalSystemFanFailed TRAP-TYPE ENTERPRISE compaq VARIABLES { cpqHeThermalDegradedAction } DESCRIPTION "The system fan status has been set to failed. A required system fan is not operating normally. The system will be shutdown if the cpqHeThermalDegradedAction variable is set to shutdown(3)." --#TYPE "System Fan Failure (6006)" --#SUMMARY "Required fan not operating normally. Shutdown may occur." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED ::= 6006 cpqHeThermalSystemFanDegraded TRAP-TYPE ENTERPRISE compaq DESCRIPTION "The system fan status has been set to degraded. An optional system fan is not operating normally." --#TYPE "System Fan Degraded (6007)" --#SUMMARY "An optional fan is not operating normally." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED ::= 6007 cpqHeThermalSystemFanOk TRAP-TYPE ENTERPRISE compaq DESCRIPTION "The system fan status has been set to ok. Any previously non-operational system fans have returned to normal operation." --#TYPE "System Fan OK (6008)" --#SUMMARY "System fan has returned to normal operation." --#ARGUMENTS {} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 6008 cpqHeThermalCpuFanFailed TRAP-TYPE ENTERPRISE compaq DESCRIPTION "The CPU fan status has been set to failed. A processor fan is not operating normally. The server will be shutdown." --#TYPE "CPU Fan Failure (6009)" --#SUMMARY "CPU fan has failed. Server will be shutdown." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE NONOPERATIONAL ::= 6009 cpqHeThermalCpuFanOk TRAP-TYPE ENTERPRISE compaq DESCRIPTION "The CPU fan status has been set to ok. Any previously non-operational processor fans have returned to normal operation." --#TYPE "CPU Fan OK (6010)" --#SUMMARY "CPU fan is now OK." --#ARGUMENTS {} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 6010 cpqHeAsrConfirmation TRAP-TYPE ENTERPRISE compaq DESCRIPTION "The server is operational again. The server has previously been shutdown by the Automatic Server Recovery (ASR) feature and has just become operational again." --#TYPE "Server Operational (6011)" --#SUMMARY "Server is operational again after ASR shutdown." --#ARGUMENTS {} --#SEVERITY MINOR --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 6011 cpqHeThermalConfirmation TRAP-TYPE ENTERPRISE compaq DESCRIPTION "The server is operational again. The server has previously been shutdown due to a thermal anomaly on the server and has just become operational again." --#TYPE "Server Operational (6012)" --#SUMMARY "Server is operational again after thermal shutdown." --#ARGUMENTS {} --#SEVERITY MINOR --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 6012 cpqHePostError TRAP-TYPE ENTERPRISE compaq DESCRIPTION "One or more POST errors occurred. Power On Self-Test (POST) errors occur during the server restart process. " --#TYPE "POST Errors Occurred (6013)" --#SUMMARY "Errors occurred during server restart." --#ARGUMENTS {} --#SEVERITY MINOR --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 6013 cpqHeFltTolPwrSupplyDegraded TRAP-TYPE ENTERPRISE compaq DESCRIPTION "The fault tolerant power supply sub-system condition has been set to degraded." --#TYPE "Server Power Supply Degraded (6014)" --#SUMMARY "The server power supply status has become degraded." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED ::= 6014 cpqHe3CorrectableMemoryError TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeCorrMemTotalErrs } DESCRIPTION "A correctable memory error occurred. The error has been corrected. The current number of correctable memory errors is reported in the variable cpqHeCorrMemTotalErrs." --#TYPE "Correctable Memory Error Occurred (6015)" --#SUMMARY "Total correctable errors = %d." --#ARGUMENTS {2} --#SEVERITY MINOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 6015 cpqHe3CorrectableMemoryLogDisabled TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeCorrMemLogStatus } DESCRIPTION "Correctable memory error tracking disabled. The frequency of errors is so high that the error tracking logic has been temporarily disabled. The cpqHeCorrMemLogStatus variable indicated the current tracking status." --#TYPE "Memory Error Tracking Disabled (6016)" --#SUMMARY "Too many memory errors - tracking now disabled." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY CRITICAL --#HWSTATUS_CATEGORY MEMORY ::= 6016 cpqHe3ThermalTempFailed TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "The temperature status has been set to failed. The system will be shutdown due to this thermal condition." --#TYPE "Thermal Failure (6017)" --#SUMMARY "System will be shutdown due to this thermal condition." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY CRITICAL --#HWSTATUS_CATEGORY THERMAL --#ACTION "Check the system for hardware failures and verify the environment is properly cooled." ::= 6017 cpqHe3ThermalTempDegraded TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeThermalDegradedAction } DESCRIPTION "The temperature status has been set to degraded. The server's temperature is outside of the normal operating range. The server will be shutdown if the cpqHeThermalDegradedAction variable is set to shutdown(3)." --#TYPE "Temperature Degraded (6018)" --#SUMMARY "Temperature out of range. Shutdown may occur." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY CRITICAL --#HWSTATUS_CATEGORY THERMAL --#ACTION "Check the system for hardware failures and verify the environment is properly cooled." ::= 6018 cpqHe3ThermalTempOk TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "The temperature status has been set to ok. The server's temperature has returned to the normal operating range." --#TYPE "Temperature OK (6019)" --#SUMMARY "Temperature has returned to normal range." --#ARGUMENTS {} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL --#SIMPLE_SEVERITY OK --#HWSTATUS_CATEGORY THERMAL ::= 6019 cpqHe3ThermalSystemFanFailed TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeThermalDegradedAction } DESCRIPTION "The system fan status has been set to failed. A required system fan is not operating normally. The system will be shutdown if the cpqHeThermalDegradedAction variable is set to shutdown(3)." --#TYPE "System Fan Failure (6020)" --#SUMMARY "Required fan not operating normally. Shutdown may occur." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY CRITICAL --#HWSTATUS_CATEGORY FAN --#ACTION "Replace the failed fan." ::= 6020 cpqHe3ThermalSystemFanDegraded TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "The system fan status has been set to degraded. An optional system fan is not operating normally." --#TYPE "System Fan Degraded (6021)" --#SUMMARY "An optional fan is not operating normally." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY CRITICAL --#HWSTATUS_CATEGORY FAN --#ACTION "Replace the failing fan." ::= 6021 cpqHe3ThermalSystemFanOk TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "The system fan status has been set to ok. Any previously non-operational system fans have returned to normal operation." --#TYPE "System Fan OK (6022)" --#SUMMARY "System fan has returned to normal operation." --#ARGUMENTS {} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL --#SIMPLE_SEVERITY OK --#HWSTATUS_CATEGORY FAN ::= 6022 cpqHe3ThermalCpuFanFailed TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "The CPU fan status has been set to failed. A processor fan is not operating normally. The server will be shutdown." --#TYPE "CPU Fan Failure (6023)" --#SUMMARY "CPU fan has failed. Server will be shutdown." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE NONOPERATIONAL --#SIMPLE_SEVERITY CRITICAL --#HWSTATUS_CATEGORY FAN --#ACTION "Replace the failed CPU fan." ::= 6023 cpqHe3ThermalCpuFanOk TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "The CPU fan status has been set to ok. Any previously non-operational processor fans have returned to normal operation." --#TYPE "CPU Fan OK (6024)" --#SUMMARY "CPU fan is now OK." --#ARGUMENTS {} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL --#SIMPLE_SEVERITY OK --#HWSTATUS_CATEGORY FAN ::= 6024 cpqHe3AsrConfirmation TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "The server is operational again. The server has previously been shutdown by the Automatic Server Recovery (ASR) feature and has just become operational again." --#TYPE "Server Operational (6025)" --#SUMMARY "Server is operational again after ASR shutdown." --#ARGUMENTS {} --#SEVERITY MINOR --#TIMEINDEX 99 --#STATE OPERATIONAL --#SIMPLE_SEVERITY MAJOR --#HWSTATUS_CATEGORY ASR --#LIFECYCLE ::= 6025 cpqHe3ThermalConfirmation TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "The server is operational again. The server has previously been shutdown due to a thermal anomaly on the server and has just become operational again." --#TYPE "Server Operational (6026)" --#SUMMARY "Server is operational again after thermal shutdown." --#ARGUMENTS {} --#SEVERITY MINOR --#TIMEINDEX 99 --#STATE OPERATIONAL --#SIMPLE_SEVERITY MAJOR --#HWSTATUS_CATEGORY THERMAL ::= 6026 cpqHe3PostError TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "One or more POST errors occurred. Power On Self-Test (POST) errors occur during the server restart process. Details of the POST error messages can be found in Integrated Management Log " --#TYPE "POST Errors Occurred (6027)" --#SUMMARY "Power on self-test errors occurred during server restart." --#ARGUMENTS {} --#SEVERITY MINOR --#TIMEINDEX 99 --#STATE OPERATIONAL --#SIMPLE_SEVERITY MAJOR --#HWSTATUS_CATEGORY LOGS --#ACTION "Refer to the Integrated Management Log for details on the POST error." ::= 6027 cpqHe3FltTolPwrSupplyDegraded TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "The fault tolerant power supply sub-system condition has been set to degraded." --#TYPE "Server Power Supply Degraded (6028)" --#SUMMARY "The server power supply status has become degraded." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY CRITICAL --#HWSTATUS_CATEGORY POWER --#ACTION "Check the system for a power supply failure. Replace the power supply." ::= 6028 -- Deprecated in 6.20 trap 6056 is the replacement cpqHe3CorrMemReplaceMemModule TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "A correctable memory log entry indicates a memory module needs to be replaced. The errors have been corrected, but the memory module should be replaced. The error information is reported in the variable cpqHeCorrMemErrDesc." --#TYPE "Corr Mem Errors Require a Replacement Memory Module. (6029)" --#SUMMARY "Correctable memory errs require a replacement memory module." --#ARGUMENTS {} --#SEVERITY MINOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 6029 -- Deprecated in 5.10 cpqHe3FltTolPowerSupplyDegraded TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeFltTolPowerSupplyChassis, cpqHeFltTolPowerSupplyBay } DESCRIPTION "The fault tolerant power supply condition has been set to degraded for the specified chassis and bay location." --#TYPE "Power Supply Degraded (6030)" --#SUMMARY "The Power Supply Degraded on Chassis %d, Bay %d." --#ARGUMENTS {2, 3} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED ::= 6030 -- Deprecated in 5.10 cpqHe3FltTolPowerSupplyFailed TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeFltTolPowerSupplyChassis, cpqHeFltTolPowerSupplyBay } DESCRIPTION "The fault tolerant power supply condition has been set to failed for the specified chassis and bay location." --#TYPE "Power Supply Failed (6031)" --#SUMMARY "The Power Supply Failed on Chassis %d, Bay %d." --#ARGUMENTS {2, 3} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE NONOPERATIONAL ::= 6031 cpqHe3FltTolPowerRedundancyLost TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeFltTolPowerSupplyChassis } DESCRIPTION "The Fault Tolerant Power Supplies have lost redundancy for the specified chassis." --#TYPE "Power Redundancy Lost (6032)" --#SUMMARY "The power supplies are no longer redundant on chassis %d." --#ARGUMENTS {2} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY MAJOR --#HWSTATUS_CATEGORY POWER --#ACTION "Check the system power supplies for a failure." ::= 6032 cpqHe3FltTolPowerSupplyInserted TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeFltTolPowerSupplyChassis, cpqHeFltTolPowerSupplyBay } DESCRIPTION "A Fault Tolerant Power Supply has been inserted into the specified chassis and bay location." --#TYPE "Power Supply Inserted (6033)" --#SUMMARY "The power supply has been inserted on chassis %d, bay %d." --#ARGUMENTS {2, 3} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL --#SIMPLE_SEVERITY OK --#HWSTATUS_CATEGORY POWER --#LIFECYCLE ::= 6033 cpqHe3FltTolPowerSupplyRemoved TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeFltTolPowerSupplyChassis, cpqHeFltTolPowerSupplyBay } DESCRIPTION "A Fault Tolerant Power Supply has been removed from the specified chassis and bay location." --#TYPE "Power Supply Removed (6034)" --#SUMMARY "The power supply has been removed on chassis %d, bay %d." --#ARGUMENTS {2, 3} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY MAJOR --#HWSTATUS_CATEGORY POWER --#LIFECYCLE ::= 6034 cpqHe3FltTolFanDegraded TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeFltTolFanChassis, cpqHeFltTolFanIndex } DESCRIPTION "The Fault Tolerant Fan condition has been set to degraded for the specified chassis and fan." --#TYPE "Fan Degraded (6035)" --#SUMMARY "The fan degraded on chassis %d, fan %d." --#ARGUMENTS {2, 3} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY CRITICAL --#HWSTATUS_CATEGORY FAN --#ACTION "Replace the failing fan." ::= 6035 cpqHe3FltTolFanFailed TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeFltTolFanChassis, cpqHeFltTolFanIndex } DESCRIPTION "The Fault Tolerant Fan condition has been set to failed for the specified chassis and fan." --#TYPE "Fan Failed (6036)" --#SUMMARY "The fan failed on chassis %d, fan %d." --#ARGUMENTS {2, 3} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE NONOPERATIONAL --#SIMPLE_SEVERITY CRITICAL --#HWSTATUS_CATEGORY FAN --#ACTION "Replace the failed fan." ::= 6036 cpqHe3FltTolFanRedundancyLost TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeFltTolFanChassis } DESCRIPTION "The Fault Tolerant Fans have lost redundancy for the specified chassis." --#TYPE "Fan Redundancy Lost (6037)" --#SUMMARY "The fans are no longer redundant on chassis %d." --#ARGUMENTS {2} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY MAJOR --#HWSTATUS_CATEGORY FAN --#ACTION "Check the system fans for a failure." ::= 6037 cpqHe3FltTolFanInserted TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeFltTolFanChassis, cpqHeFltTolFanIndex } DESCRIPTION "A Fault Tolerant Fan has been inserted into the specified chassis and fan location." --#TYPE "Fan Inserted (6038)" --#SUMMARY "The fan has been inserted on chassis %d, fan %d." --#ARGUMENTS {2, 3} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL --#SIMPLE_SEVERITY OK --#HWSTATUS_CATEGORY FAN --#LIFECYCLE ::= 6038 cpqHe3FltTolFanRemoved TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeFltTolFanChassis, cpqHeFltTolFanIndex } DESCRIPTION "A Fault Tolerant Fan has been removed from the specified chassis and fan location." --#TYPE "Fan Removed (6039)" --#SUMMARY "The fan has been removed on chassis %d, fan %d." --#ARGUMENTS {2, 3} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY MAJOR --#HWSTATUS_CATEGORY FAN --#LIFECYCLE ::= 6039 cpqHe3TemperatureFailed TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeTemperatureChassis, cpqHeTemperatureLocale } DESCRIPTION "The temperature status has been set to failed in the specified chassis and location. The system will be shutdown due to this condition." --#TYPE "Thermal Failure (6040)" --#SUMMARY "Temperature exceeded on chassis %d, location %d." --#ARGUMENTS {2, 3} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY CRITICAL --#HWSTATUS_CATEGORY THERMAL --#ACTION "Check the system for hardware failures and verify the environment is properly cooled." ::= 6040 cpqHe3TemperatureDegraded TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeThermalDegradedAction, cpqHeTemperatureChassis, cpqHeTemperatureLocale } DESCRIPTION "The temperature status has been set to degraded in the specified chassis and location. The server's temperature is outside of the normal operating range. The server will be shutdown if the cpqHeThermalDegradedAction variable is set to shutdown(3)." --#TYPE "Thermal Status Degraded (6041)" --#SUMMARY "Temperature out of range on chassis %d, location %d. Shutdown may occur." --#ARGUMENTS {3, 4} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY CRITICAL --#HWSTATUS_CATEGORY THERMAL --#ACTION "Check the system for hardware failures and verify the environment is properly cooled." ::= 6041 cpqHe3TemperatureOk TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeTemperatureChassis, cpqHeTemperatureLocale } DESCRIPTION "The temperature status has been set to ok in the specified chassis and location. The server's temperature has returned to the normal operating range." --#TYPE "Thermal Status OK (6042)" --#SUMMARY "Temperature normal on chassis %d, location %d." --#ARGUMENTS {2, 3} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL --#SIMPLE_SEVERITY OK --#HWSTATUS_CATEGORY THERMAL ::= 6042 cpqHe3PowerConverterDegraded TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHePwrConvChassis, cpqHePwrConvSlot, cpqHePwrConvSocket } DESCRIPTION "The DC-DC Power Converter condition has been set to degraded for the specified chassis, slot and socket." --#TYPE "Power Converter Degraded (6043)" --#SUMMARY "The power converter degraded on chassis %d, slot %d, socket %d." --#ARGUMENTS {2, 3, 4} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY CRITICAL --#HWSTATUS_CATEGORY POWER --#ACTION "Check for a failing power converter or for a failed power converter in a redundant pair. Replace the power converter." ::= 6043 cpqHe3PowerConverterFailed TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHePwrConvChassis, cpqHePwrConvSlot, cpqHePwrConvSocket } DESCRIPTION "The DC-DC Power Converter condition has been set to failed for the specified chassis, slot and socket." --#TYPE "Power Converter Failed (6044)" --#SUMMARY "The power converter failed on chassis %d, slot %d, socket %d." --#ARGUMENTS {2, 3, 4} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE NONOPERATIONAL --#SIMPLE_SEVERITY CRITICAL --#HWSTATUS_CATEGORY POWER --#ACTION "Replace the failed power converter." ::= 6044 cpqHe3PowerConverterRedundancyLost TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHePwrConvChassis } DESCRIPTION "The DC-DC Power Converters have lost redundancy for the specified chassis." --#TYPE "Power Converter Redundancy Lost (6045)" --#SUMMARY "The power converters are no longer redundant on chassis %d." --#ARGUMENTS {2} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY CRITICAL --#HWSTATUS_CATEGORY POWER --#ACTION "Check the power converters in the system for a failure in a redundant pair. Replace the power converter." ::= 6045 cpqHe3CacheAccelParityError TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "A cache accelerator parity error indicates a cache module needs to be replaced. The error information is reported in the variable cpqHeEventLogErrorDesc." --#TYPE "Cache Accel Parity Errors may require a module. (6046)" --#SUMMARY "Cache accelerator errors may require a replacement module." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE NONOPERATIONAL --#SIMPLE_SEVERITY CRITICAL --#HWSTATUS_CATEGORY MEMORY --#ACTION "Refer to the Integrated Management Log for details on the error. Replace the cache module." ::= 6046 cpqHeResilientMemOnlineSpareEngaged TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "Advanced Memory Protection Online Spare Engaged. The Advanced Memory Protection subsystem has detected a memory fault. The Online Spare Memory has been activated. User Action: Schedule server down-time to replace the faulty memory." --#TYPE "Online Spare Memory Engaged (6047)" --#SUMMARY "The Advanced Memory Protection subsystem has engaged the online spare memory." --#ARGUMENTS {} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY MAJOR --#HWSTATUS_CATEGORY MEMORY --#ACTION "Schedule server down-time to replace the faulty memory." ::= 6047 -- New for rev 5.10. cpqHe4FltTolPowerSupplyOk TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeFltTolPowerSupplyChassis, cpqHeFltTolPowerSupplyBay, cpqHeFltTolPowerSupplyStatus, cpqHeFltTolPowerSupplyModel, cpqHeFltTolPowerSupplySerialNumber, cpqHeFltTolPowerSupplyAutoRev, cpqHeFltTolPowerSupplyFirmwareRev, cpqHeFltTolPowerSupplySparePartNum, cpqSiServerSystemId } DESCRIPTION "The fault tolerant power supply condition has been set back to the OK state for the specified chassis and bay location." --#TYPE "Power Supply OK (6048)" --#SUMMARY "The power supply is ok on chassis %d, bay %d, status %d, model %s, serial number %s, firmware %s." --#ARGUMENTS {2, 3, 4, 5, 6, 8} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL --#SIMPLE_SEVERITY OK --#HWSTATUS_CATEGORY POWER ::= 6048 -- New for rev 5.10. Deprecated cpqHe3FltTolPowerSupplyDegraded cpqHe4FltTolPowerSupplyDegraded TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeFltTolPowerSupplyChassis, cpqHeFltTolPowerSupplyBay, cpqHeFltTolPowerSupplyStatus, cpqHeFltTolPowerSupplyModel, cpqHeFltTolPowerSupplySerialNumber, cpqHeFltTolPowerSupplyAutoRev, cpqHeFltTolPowerSupplyFirmwareRev, cpqHeFltTolPowerSupplySparePartNum, cpqSiServerSystemId } DESCRIPTION "The fault tolerant power supply condition has been set to degraded for the specified chassis and bay location." --#TYPE "Power Supply Degraded (6049)" --#SUMMARY "The power supply is degraded on chassis %d, bay %d, status %d, model %s, serial number %s, firmware %s." --#ARGUMENTS {2, 3, 4, 5, 6, 8} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY CRITICAL --#HWSTATUS_CATEGORY POWER --#ACTION "Replace the failing power supply." ::= 6049 -- New for rev 5.10. Deprecated cpqHe3FltTolPowerSupplyFailed cpqHe4FltTolPowerSupplyFailed TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeFltTolPowerSupplyChassis, cpqHeFltTolPowerSupplyBay, cpqHeFltTolPowerSupplyStatus, cpqHeFltTolPowerSupplyModel, cpqHeFltTolPowerSupplySerialNumber, cpqHeFltTolPowerSupplyAutoRev, cpqHeFltTolPowerSupplyFirmwareRev, cpqHeFltTolPowerSupplySparePartNum, cpqSiServerSystemId } DESCRIPTION "The fault tolerant power supply condition has been set to failed for the specified chassis and bay location." --#TYPE "Power Supply Failed (6050)" --#SUMMARY "The power supply is failed on chassis %d, bay %d, status %d, model %s, serial number %s, firmware %s." --#ARGUMENTS {2, 3, 4, 5, 6, 8} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE NONOPERATIONAL --#SIMPLE_SEVERITY CRITICAL --#HWSTATUS_CATEGORY POWER --#ACTION "Replace the failed power supply." ::= 6050 -- New for rev 5.40. cpqHeResilientMemMirroredMemoryEngaged TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "Advanced Memory Protection Mirrored Memory Engaged. The Advanced Memory Protection subsystem has detected a memory fault. Mirrored Memory has been activated. User Action: Replace the faulty memory." --#TYPE "Mirrored Memory Engaged (6051)" --#SUMMARY "The Advanced Memory Protection subsystem has engaged the online spare memory." --#ARGUMENTS {} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY MAJOR --#HWSTATUS_CATEGORY MEMORY --#ACTION "Replace the faulty memory." ::= 6051 -- New for rev 5.50. cpqHeResilientAdvancedECCMemoryEngaged TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "Advanced Memory Protection Advanced ECC Memory Engaged. The Advanced Memory Protection subsystem has detected a memory fault. Advanced ECC has been activated. User Action: Replace the faulty memory." --#TYPE "Advanced ECC Memory Engaged (6052)" --#SUMMARY "The Advanced Memory Protection subsystem has engaged the advanced ECC memory." --#ARGUMENTS {} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY MAJOR --#HWSTATUS_CATEGORY MEMORY --#ACTION "Replace the faulty memory." ::= 6052 -- New traps added for 6.20. cpqHeResilientMemXorMemoryEngaged TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "Advanced Memory Protection XOR Engine Memory Engaged. The Advanced Memory Protection subsystem has detected a memory fault. The XOR engine has been activated. User Action: Replace the faulty memory." --#TYPE "Advanced XOR Memory Engaged (6053)" --#SUMMARY "The Advanced Memory Protection subsystem has engaged the XOR memory." --#ARGUMENTS {} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY MAJOR --#HWSTATUS_CATEGORY MEMORY --#ACTION "Replace the faulty memory." ::= 6053 cpqHe3FltTolPowerRedundancyRestored TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeFltTolPowerSupplyChassis } DESCRIPTION "The Fault Tolerant Power Supplies have returned to a redundant state for the specified chassis." --#TYPE "Power Redundancy Restored (6054)" --#SUMMARY "The power supplies are now redundant on chassis %d." --#ARGUMENTS {2} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL --#SIMPLE_SEVERITY OK --#HWSTATUS_CATEGORY POWER ::= 6054 cpqHe3FltTolFanRedundancyRestored TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeFltTolFanChassis } DESCRIPTION "The Fault Tolerant Fans have returned to a redundant state for the specified chassis." --#TYPE "Fan Redundancy Restored (6055)" --#SUMMARY "The fans are now redundant on chassis %d." --#ARGUMENTS {2} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL --#SIMPLE_SEVERITY OK --#HWSTATUS_CATEGORY FAN ::= 6055 -- Updated for 6.20 trap replaced 6029 -- deprecateed in 8.20 replaced with 6064 cpqHe4CorrMemReplaceMemModule TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeResMemBoardIndex, cpqHeResMemModuleIndex, cpqHeResMemModuleSparePartNo, cpqSiMemModuleSize, cpqSiServerSystemId } DESCRIPTION "Corrected Memory Errors Detected The errors have been corrected, but the memory module should be replaced." --#TYPE "Corrected Memory Errors - Replace Memory Module. (6056)" --#SUMMARY "Correctable memory errors require a replacement of the memory module in slot %d, socket %d." --#ARGUMENTS {2, 3} --#SEVERITY MINOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 6056 -- deprecateed in 8.20 replaced with 6065 cpqHeResMemBoardRemoved TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeResMemBoardSlotIndex } DESCRIPTION "Memory board or cartridge removed. An Advanced Memory Protection sub-system board or cartridge has been removed from the system. User Action: Insure the board or cartridge has memory correctly installed and re-insert the memory board or cartridge back into the system." --#TYPE "Memory Board or Cartridge Removed (6057)" --#SUMMARY "Memory Board or Cartridge Removed from Slot %d." --#ARGUMENTS {2} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 6057 -- deprecateed in 8.20 replaced with 6066 cpqHeResMemBoardInserted TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeResMemBoardSlotIndex } DESCRIPTION "Memory board or cartridge inserted. An Advanced Memory Protection sub-system board or cartridge has been inserted into the system. User Action: None." --#TYPE "Memory Board or Cartridge Inserted (6058)" --#SUMMARY "Memory Board or Cartridge Inserted into Slot %d." --#ARGUMENTS {2} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 6058 -- deprecateed in 8.20 replaced with 6067 cpqHeResMemBoardBusError TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeResMemBoardSlotIndex } DESCRIPTION "Memory board or cartridge bus error detected. An Advanced Memory Protection sub-system board or cartridge bus error has been detected. User Action: Replace the indicated board or cartridge." --#TYPE "Memory Board or Cartridge Bus Error Detected (6059)" --#SUMMARY "Memory Board or Cartridge Bus Error Detected in Slot %d." --#ARGUMENTS {2} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED ::= 6059 -- The follow trap 6060 is supported only in Tru64 at this time. -- This trap is not currently supported for ProLiants. cpqHeEventOccurred TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeEventLogEntryNumber, cpqHeEventLogEntrySeverity, cpqHeEventLogUpdateTime, cpqHeEventLogErrorDesc } DESCRIPTION "An event has occurred. User Action: None." --#TYPE "Event has occurred (6060)" --#SUMMARY "Event %s has occurred, severity %d " --#ARGUMENTS {5,3} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL --#SIMPLE_SEVERITY OK --#HWSTATUS_CATEGORY NONE ::= 6060 cpqHeManagementProcInReset TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "The Management processor is currently in reset The management processor is currently in the process of being reset because of a firmware update or some other event. User action: None" --#TYPE "Management processor is currently in reset. (6061)" --#SUMMARY "The management processor is in the process of being reset." --#ARGUMENTS {} --#SEVERITY MINOR --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY MAJOR --#HWSTATUS_CATEGORY MANAGEMENTPROCESSOR ::= 6061 cpqHeManagementProcReady TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "The Management processor is ready The management processor has successfully reset and is now available again. User action: None" --#TYPE "Management processor is ready. (6062)" --#SUMMARY "The management processor is ready after a successfull reset." --#ARGUMENTS {} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL --#SIMPLE_SEVERITY OK --#HWSTATUS_CATEGORY MANAGEMENTPROCESSOR ::= 6062 cpqHeManagementProcFailedReset TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "The Management processor failed reset The management processor was not successfully reset and is not operational. User action: Reset the management procesessor again or re-flash the management processor firmware." --#TYPE "Management processor failed reset. (6063)" --#SUMMARY "The management processor failed reset." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE NONOPERATIONAL --#SIMPLE_SEVERITY CRITICAL --#HWSTATUS_CATEGORY MANAGEMENTPROCESSOR --#ACTION "Reset the management procesessor again or re-flash the management processor firmware." ::= 6063 -- Updated for 8.20 trap replaced 6056 cpqHe5CorrMemReplaceMemModule TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeResMem2BoardNum, cpqHeResMem2CpuNum, cpqHeResMem2RiserNum, cpqHeResMem2ModuleNum, cpqHeResMem2ModulePartNo, cpqHeResMem2ModuleSize, cpqSiServerSystemId } DESCRIPTION "Corrected \ uncorrected Memory Errors Detected The errors have been corrected, but the memory module should be replaced. Value 0 for CPU means memory is not Processor based" --#TYPE "Corrected \ uncorrectable Memory Errors - Replace Memory Module. (6064)" --#SUMMARY "Correctable \ uncorrectable memory errors require a replacement of the memory module in slot %d, cpu %d, riser %d, socket %d." --#ARGUMENTS {2, 3, 4, 5} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY MAJOR --#HWSTATUS_CATEGORY MEMORY --#ACTION "Replace the failing memory module." ::= 6064 -- Updated for 8.20 trap replaced 6057 cpqHe5ResMemBoardRemoved TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeResMem2BoardSlotNum, cpqHeResMem2BoardCpuNum, cpqHeResMem2BoardRiserNum } DESCRIPTION "Memory board or cartridge or riser removed. An Advanced Memory Protection sub-system board or cartridge or riser has been removed from the system. Value 0 for CPU means memory is not processor based. User Action: Insure the board or cartridge or riser has memory correctly installed and re-insert the memory board or cartridge or CPU back into the system." --#TYPE "Memory Board or Cartridge or Riser Removed (6065)" --#SUMMARY "Memory board or cartridge or riser removed from slot %d, CPU %d, riser %d." --#ARGUMENTS {2,3,4} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE OPERATIONAL --#SIMPLE_SEVERITY MAJOR --#HWSTATUS_CATEGORY MEMORY --#LIFECYCLE ::= 6065 -- Updated for 8.20 trap replaced 6058 cpqHe5ResMemBoardInserted TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeResMem2BoardSlotNum, cpqHeResMem2BoardCpuNum, cpqHeResMem2BoardRiserNum } DESCRIPTION "Memory board or cartridge or riser inserted. An Advanced Memory Protection sub-system board or cartridge or riser Has been inserted into the system. Value 0 for CPU means memory is not processor based. User Action: None." --#TYPE "Memory Board or Cartridge Inserted (6066)" --#SUMMARY "Memory board or cartridge inserted into slot %d, CPU %d, riser %d." --#ARGUMENTS {2,3,4} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL --#SIMPLE_SEVERITY OK --#HWSTATUS_CATEGORY MEMORY --#LIFECYCLE ::= 6066 -- Updated for 8.20 trap replaced 6059 cpqHe5ResMemBoardBusError TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeResMem2BoardSlotNum, cpqHeResMem2BoardCpuNum, cpqHeResMem2BoardRiserNum } DESCRIPTION "Memory board or cartridge or Riser bus error detected. An Advanced Memory Protection sub-system board or cartridge or Riser bus error has been detected. Value 0 for CPU means memory is not processor based. User Action: Replace the indicated board or cartridge or Riser." --#TYPE "Memory Board or Cartridge or Riser Bus Error Detected (6067)" --#SUMMARY "Memory board or cartridge bus error detected in slot %d, CPU %d, riser %d." --#ARGUMENTS {2,3,4} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY CRITICAL --#HWSTATUS_CATEGORY MEMORY --#ACTION "Replace the indicated board, cartridge, or riser." ::= 6067 -- Added for 8.20 cpqHeResilientMemLockStepMemoryEngaged TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "Advanced Memory Protection LockStep Engine Memory Engaged. The Advanced Memory Protection subsystem has detected a memory fault. The LockStep engine has been activated. User Action: Replace the faulty memory." --#TYPE "Advanced LockStep Memory Engaged (6068)" --#SUMMARY "The Advanced Memory Protection subsystem has engaged the LockStep memory." --#ARGUMENTS {} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED --#SIMPLE_SEVERITY MAJOR --#HWSTATUS_CATEGORY MEMORY --#ACTION "Replace the faulty memory." ::= 6068 -- New for rev 8.30. cpqHe4FltTolPowerSupplyACpowerloss TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqHeFltTolPowerSupplyChassis, cpqHeFltTolPowerSupplyBay, cpqHeFltTolPowerSupplyStatus, cpqHeFltTolPowerSupplyModel, cpqHeFltTolPowerSupplySerialNumber, cpqHeFltTolPowerSupplyAutoRev, cpqHeFltTolPowerSupplyFirmwareRev, cpqHeFltTolPowerSupplySparePartNum, cpqSiServerSystemId } DESCRIPTION "The fault tolerant power supply AC power loss for the specified chassis and bay location." --#TYPE "Power Supply AC Power Loss (6069)" --#SUMMARY "The power supply AC power loss in %d, bay %d, status %d, model %s, serial number %s, firmware %s." --#ARGUMENTS {2, 3, 4, 5, 6, 8} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE NONOPERATIONAL --#SIMPLE_SEVERITY CRITICAL --#HWSTATUS_CATEGORY POWER --#ACTION "Check the power source for the specified power supply." ::= 6069 END