ZTSAMIB

File: ZTSAMIB.mib (14645 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC-1215
RFC1213-MIB

Imported symbols

private IpAddress Counter
OBJECT-TYPE TRAP-TYPE DisplayString

Defined Types

ZtsaTableEntry  
SEQUENCE    
  ztsaTcpIpName DisplayString
  ztsaTcpIpStatus INTEGER

ZtsaSubnetEntry  
SEQUENCE    
  ztsaSubnetName DisplayString
  ztsaSubnetStatus INTEGER
  ztsaSubnetAddr IpAddress

Defined Values

enterprises 1.3.6.1.4.1
OBJECT IDENTIFIER    

tandem 1.3.6.1.4.1.169
OBJECT IDENTIFIER    

nonstopsystems 1.3.6.1.4.1.169.3
OBJECT IDENTIFIER    

ztsa 1.3.6.1.4.1.169.3.202
OBJECT IDENTIFIER    

ztsaAgentName 1.3.6.1.4.1.169.3.202.1
the name of the SNMP Agent process.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

ztsaAgentState 1.3.6.1.4.1.169.3.202.2
current status of the agent interface. The state of this variable will always be connected(1) when returned in a management request
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER connected(1), disconnected(2)  

ztsaProcessName 1.3.6.1.4.1.169.3.202.3
the fully qualified NSK process name of this subagent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..49)  

ztsaProcessVersion 1.3.6.1.4.1.169.3.202.4
the version of this subagent process object file. Format: T7862xxx_ddmmmyy_TCPIPSA
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

ztsaProgramFile 1.3.6.1.4.1.169.3.202.5
the TCP/IP subagent program file name
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..36)  

ztsaProcessPriority 1.3.6.1.4.1.169.3.202.6
the current NSK process priority of this subagent process.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..199  

ztsaProcessGroupID 1.3.6.1.4.1.169.3.202.7
the NSK process group ID part of the PAID for this subagent process.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

ztsaProcessUserID 1.3.6.1.4.1.169.3.202.8
the NSK process user ID part of the PAID for this subagent process.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

ztsaPrimaryCPU 1.3.6.1.4.1.169.3.202.9
The CPU number of the primary process of this subagent
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

ztsaPrimaryPIN 1.3.6.1.4.1.169.3.202.10
The process number of the primary process of this subagent
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

ztsaBackupCPU 1.3.6.1.4.1.169.3.202.11
The CPU the backup process will start in or is running in. ztsaBackupState must be set to disabled(3) prior to setting this object
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -1..255  

ztsaBackupPIN 1.3.6.1.4.1.169.3.202.12
The process number of the backup process of this subagent. Its value is -1 when the backup is not running
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER -1..255  

ztsaBackupState 1.3.6.1.4.1.169.3.202.13
The state of the backup process of this subagent. The settable values for this object are disabled(3) and enabled(4). The connected(1) and disconnected(2) states are set by the subagent to reflect the running state of the backup resource
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER connected(1), disconnected(2), disabled(3), enabled(4)  

ztsaSwitchToBackupNow 1.3.6.1.4.1.169.3.202.14
This object normally reads 0 (autoProcessPairControl) . Setting this object to 1 (forceBackupTakeover) causes the subagent to switch to its backup process immediately after replying OK. Setting this object is only permitted if the ztsaBackupState is connected(1)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER autoProcessPairControl(0), forceBackupTakeover(1)  

ztsaEmsCollectorName 1.3.6.1.4.1.169.3.202.15
the process name of the EMS Collector the subagent should send its EMS events to. ztsaEmsCollectorState must be set to disabled(3) prior to setting this object
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..15)  

ztsaEmsCollectorState 1.3.6.1.4.1.169.3.202.16
The state of the connection to the EMS Collector. The settable values for this object are disabled(3) and enabled(4). The connected(1) and disconnected(2) states are set by the subagent to reflect the running state of the EMS collector interface
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER connected(1), disconnected(2), disabled(3), enabled(4)  

ztsaKeepAliveTimer 1.3.6.1.4.1.169.3.202.17
The number of seconds between attempts the subagent makes to connect to an SNMP Agent, TCP/IP, or restart the backup process.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..32000  

ztsaRefreshNow 1.3.6.1.4.1.169.3.202.18
This object normally reads 0 (autoDynamicRefresh). Setting this object to 1 (forceDynamicRefresh) causes the subagent to update the MIB tables and generate traps (if needed). The object will return a value of 1 until the refresh is complete.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER autoDynamicRefresh(0), forceDynamicRefresh(1)  

ztsaStatsCache 1.3.6.1.4.1.169.3.202.19
The cache update interval (in seconds) for SPI STATISTICS command based objects. Value 0 disables cache timing such that updates occur to objects derived from STATISTICS only when the ztsaRefreshNow object is set
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..32000  

ztsaStatusCache 1.3.6.1.4.1.169.3.202.20
The cache update interval (in seconds) for SPI STATUS command based objects. Value 0 disables cache timing such that updates occur to objects derived from STATUS only when the ztsaRefreshNow object is set. This value is also used to control the interval for determining if a linkUp or linkDown trap should be generated
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..32000  

ztsaInfoCache 1.3.6.1.4.1.169.3.202.21
The cache update interval for SPI INFO command based objects. Value 0 disables cache timing such that updates occur to objects derived from INFO only when the refreshNow object is set
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..32000  

ztsaTcpIpProcess 1.3.6.1.4.1.169.3.202.22
The TCP/IP process being monitored by the subagent. ztsaTcpIpState must be set to disabled(3) prior to setting this object
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

ztsaTcpIpState 1.3.6.1.4.1.169.3.202.23
The state of the connection to the monitored TCP/IP process. The settable values for this object are disabled(3) and enabled(4). The connected(1) and disconnected(2) states are set by the subagent to reflect the running state of the TCP/IP resource interface
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER connected(1), disconnected(2), disabled(3), enabled(4)  

ztsaScpProcess 1.3.6.1.4.1.169.3.202.25
the name of the SCP process used for SPI requests. Value is set by the -scp startup parameter. Default is
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

ztsaTcpIpTable 1.3.6.1.4.1.169.3.202.26
This table holds information about the TCP/IP processes
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZtsaTableEntry

ztsaTableEntry 1.3.6.1.4.1.169.3.202.26.1
This entry contains information related to TCP/IP processes
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ZtsaTableEntry  

ztsaTcpIpName 1.3.6.1.4.1.169.3.202.26.1.1
The TCP/IP process name monitored by the TCP/IP SA
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ztsaTcpIpStatus 1.3.6.1.4.1.169.3.202.26.1.2
The status of TCP/IP process monitored by the TCP/IP SA
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2)  

ztsaSubnetTable 1.3.6.1.4.1.169.3.202.27
This table holds the subnets information associated with the TCP/IP processes
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZtsaSubnetEntry

ztsaSubnetEntry 1.3.6.1.4.1.169.3.202.27.1
This entry contains information related to the subnets associated with the TCP/IP processes
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ZtsaSubnetEntry  

ztsaSubnetName 1.3.6.1.4.1.169.3.202.27.1.1
The Subnet name corresponding to the TCP/IP process monitored by TCP/IP SA
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ztsaSubnetStatus 1.3.6.1.4.1.169.3.202.27.1.2
The status of the Subnet corresponding to the TCP/IP process monitored by TCP/IP SA
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER aborting(0), defined(1), diagnosis(2), started(3), starting(4), stopped(5), stopping(6), suspended(7), unknown(8), suspending(9)  

ztsaSubnetAddr 1.3.6.1.4.1.169.3.202.27.1.3
The IP address of the Subnet corresponding to the TCP/IP process monitored by TCP/IP SA
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress