ZTE-AN-PORT-IDENTIFICATION-MIB
File:
ZTE-AN-PORT-IDENTIFICATION-MIB.mib (7519 bytes)
Imported modules
Imported symbols
Defined Types
ZxAnPortIdIfConfEntry |
|
SEQUENCE |
|
|
|
|
zxAnPortIdIfConfRid |
DisplayString |
|
|
zxAnPortIdIfConfUserDefinedCid |
DisplayString |
|
Defined Values
zxAnPortIdentificationMib |
1.3.6.1.4.1.3902.1082.70.50 |
This MIB defines managed objects of port identification
for Access Node. |
MODULE-IDENTITY |
|
|
|
zxAnPortIdAccessNodeIdType |
1.3.6.1.4.1.3902.1082.70.50.1.2 |
Access Node Identifier type. There are three types:
- inbandMac: the inband mac of access node
- accessNodeName: the name of access node.
- sysName: the system name.
If set to inbandMac, the inband mac will be used
as the Access-Node-ID or Access-Node-ID1 in the
circuit ID;
If set to accessNodeName, the name of access node
will be used;
If set to sysName, the system name will be used.
C6XX only support inbandMac(1), accessNodeName(2).
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
inbandMac(1), accessNodeName(2), sysName(3) |
|
zxAnPortIdRack |
1.3.6.1.4.1.3902.1082.70.50.1.4 |
Rack Number of access node, which will be used in circuit ID. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..63 |
|
zxAnPortIdShelf |
1.3.6.1.4.1.3902.1082.70.50.1.5 |
Shelf Number of access node, which will be used in circuit ID. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..31 |
|
zxAnPortIdIfConfEntry |
1.3.6.1.4.1.3902.1082.70.50.2.1.1 |
The entry of the table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
ZxAnPortIdIfConfEntry |
|
|
zxAnPortIdIfConfRid |
1.3.6.1.4.1.3902.1082.70.50.2.1.1.3 |
The remote ID, which is a string with maximum length 64. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..64) |
|
zxAnPortIdIfConfUserDefinedCid |
1.3.6.1.4.1.3902.1082.70.50.2.1.1.5 |
The user-defined circuit ID, which is a string with maximum length 64.
It will be used as the circuit ID of an interface, if the format of the
interface is set to franceTel(9). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..64) |
|
zxAnPortIdCompliance |
1.3.6.1.4.1.3902.1082.70.50.4.1.1 |
The compliance statement for entities which implement the
ZTE-AN-PORT-IDENTIFICATION-MIB. |
Status: current |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|
zxAnPortIdGlobalGroup |
1.3.6.1.4.1.3902.1082.70.50.4.2.1 |
A collection of global objects providing port-identification
functions. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
zxAnPortIdGroup |
1.3.6.1.4.1.3902.1082.70.50.4.2.2 |
A collection of interface objects providing port-identification
functions. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|