ZxAnPonProtectGroupEntry |
|
SEQUENCE |
|
|
|
|
zxAnPonProtectGroupId |
Unsigned32 |
|
|
zxAnPonProtectGroupName |
DisplayString |
|
|
zxAnPonProtectGroupWorkPort |
InterfaceIndex |
|
|
zxAnPonProtectGroupProtectPort |
InterfaceIndex |
|
|
zxAnPonProtectType |
INTEGER |
|
|
zxAnPonProtectSubType |
INTEGER |
|
|
zxAnPonProtectSystemMode |
INTEGER |
|
|
zxAnPonProtectPeerAddrType |
InetAddressType |
|
|
zxAnPonProtectPeerIpAddr |
InetAddress |
|
|
zxAnPonProtectSpanNeEncryptKey |
DisplayString |
|
|
zxAnPonProtectGroupRowStatus |
RowStatus |
|
ZxAnPonProtectGroupPropEntry |
|
SEQUENCE |
|
|
|
|
zxAnPonProtectActiveChannel |
INTEGER |
|
|
zxAnPonProtectRevertMode |
INTEGER |
|
|
zxAnPonProtectWtrInterval |
Integer32 |
|
|
zxAnPonProtectLastApsRequest |
INTEGER |
|
|
zxAnPonProtectWorkLinkStatus |
INTEGER |
|
|
zxAnPonProtectPrtcLinkStatus |
INTEGER |
|
|
zxAnPonProtectPonAlmDuration |
Integer32 |
|
ZxAnPonProtectActionEntry |
|
SEQUENCE |
|
|
|
|
zxAnPonProtectSwitchCommand |
INTEGER |
|
|
zxAnPonProtectSwitchOnuList |
OCTET STRING |
|
ZxAnPonProtectGroupExtPropEntry |
|
SEQUENCE |
|
|
|
|
zxAnPonProtectWorkChannelOnuId |
Integer32 |
|
|
zxAnPonProtectChannelOnuId |
Integer32 |
|
|
zxAnPonProtectOnuActiveChannel |
INTEGER |
|
|
zxAnPonProtectOnuLastApsRequest |
INTEGER |
|
|
zxAnPonProtectOnuWorkLinkStatus |
INTEGER |
|
|
zxAnPonProtectOnuPrtcLinkStatus |
INTEGER |
|
|
zxAnPonProtectOnuLinkAlmDuration |
Integer32 |
|
|
zxAnPonProtectExtPropRowStatus |
RowStatus |
|
zxAnPonProtectGroupEntry |
1.3.6.1.4.1.3902.1082.500.5.2.1.1 |
Pon protection group entry.
Entries in the zxAnPonProtectGroupTable are created and
deleted using the zxAnPonProtectGroupRowStatus object,
modify is prohibited.
The multi-variables binding rule should be complied with
when a manager configures protection group. According to this rule,
all the related mib variables must be included in one SNMP
set operation.
There are two types of variables: mandatory and optional.
All of the mandatory variables must be included in one SNMP
set operation. Optional variables may be included in one
SNMP set operation with the mandatory variables, but must
not be used alone.
To create protection group, the mandatory and optional variables
are as follows:
mandatoty: zxAnPonProtectGroupName,
zxAnPonProtectGroupWorkPort,
zxAnPonProtectGroupProtectPort,
zxAnPonProtectType
optional:none |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
ZxAnPonProtectGroupEntry |
|
|
zxAnPonProtectGroupPropEntry |
1.3.6.1.4.1.3902.1082.500.5.2.2.1 |
Property of a PON protection group. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
ZxAnPonProtectGroupPropEntry |
|
|
zxAnPonProtectLastApsRequest |
1.3.6.1.4.1.3902.1082.500.5.2.2.1.4 |
The last automatic protection switch request status. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noRequest(1), doNotRevert(2), reverseRequest(3), exercise(4), waitToRestore(5), manualSwitchToProtection(6), manualSwitchToWork(7), workSignalDegrade(8), protectionSignalDegrade(9), workSignalFail(10), protectionSignalFail(11), forcedSwitchToProtection(12), forcedSwitchToWork(13), lockoutOfProtection(14) |
|
zxAnPonProtectActionEntry |
1.3.6.1.4.1.3902.1082.500.5.2.3.1 |
Action of a PON protection group. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
ZxAnPonProtectActionEntry |
|
|
zxAnPonProtectGroupExtPropEntry |
1.3.6.1.4.1.3902.1082.500.5.2.4.1 |
PON protection group extend property entry,
only for type C and type D protection.
Entries in the zxAnPonProtectGroupExtPropTable are created and
deleted using the zxAnPonProtectExtPropRowStatus object.
modify is prohibited.
The multi-variables binding rule should be complied with
when a manager configures protection group. According to this rule,
all the related mib variables must be included in one SNMP
set operation.
There are two types of variables: mandatory and optional.
All of the mandatory variables must be included in one SNMP
set operation. Optional variables may be included in one
SNMP set operation with the mandatory variables, but must
not be used alone.
To create protection group extend property, the mandatory and
optional variables are as follows:
mandatoty: zxAnPonProtectProtectChannelOnuId
optional:none |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
ZxAnPonProtectGroupExtPropEntry |
|
|
zxAnPonProtectOnuLastApsRequest |
1.3.6.1.4.1.3902.1082.500.5.2.4.1.4 |
ONU last automatic protection switch request status. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noRequest(1), doNotRevert(2), reverseRequest(3), exercise(4), waitToRestore(5), manualSwitchToProtection(6), manualSwitchToWork(7), workSignalDegrade(8), protectionSignalDegrade(9), workSignalFail(10), protectionSignalFail(11), forcedSwitchToProtection(12), forcedSwitchToWork(13), lockoutOfProtection(14) |
|
zxAnPonProtectExtPropRowStatus |
1.3.6.1.4.1.3902.1082.500.5.2.4.1.50 |
The status of this conceptual row.
The supported actions of this conceptual row only include:
'createAndGo' and 'destroy'.
To create a row in this table, a manager must
set this object to createAndGo(4).
In particular, a newly created row cannot be created
until the corresponding zxAnPonProtectWorkChannelOnuId
and zxAnPonProtectChannelOnuId have been set.
To delete a row in this table, a manager must
set this object to destroy(6).
To get this object, the agent always returns active(1). |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
RowStatus |
|
|