ZHONE-SECHTOR100-MIB
File:
ZHONE-SECHTOR100-MIB.mib (23717 bytes)
Imported modules
Imported symbols
Defined Types
Sechtor100ConfigEntry |
|
SEQUENCE |
|
|
|
|
sechtor100PeerMacAddress |
MacAddress |
|
|
sechtor100RedundancyEnable |
TruthValue |
|
|
sechtor100FanOperationalStatus |
INTEGER |
|
|
sechtor100ThermoAUpperThreshold |
Integer32 |
|
|
sechtor100ThermoBUpperThreshold |
Integer32 |
|
|
sechtor100ThermoALowerThreshold |
Integer32 |
|
|
sechtor100ThermoBLowerThreshold |
Integer32 |
|
|
sechtor100ThermoATemperature |
Integer32 |
|
|
sechtor100ThermoBTemperature |
Integer32 |
|
|
sechtor100ThermoAOperationalStatus |
INTEGER |
|
|
sechtor100ThermoBOperationalStatus |
INTEGER |
|
|
sechtor100RowStatus |
ZhoneRowStatus |
|
Defined Values
zhoneSechtor100 |
1.3.6.1.4.1.5504.6.19 |
MIB module for elements specific to Sechtor 100 products. |
MODULE-IDENTITY |
|
|
|
sechtor100Environment |
1.3.6.1.4.1.5504.2.4.1.1 |
All the scalar objects under sechor100Environment are deprecated
and replaced by their respective objects indexed by zhoneShelfIndex
and zhoneSlotIndex.
|
Status: deprecated |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
s100FanOperationalStatus |
1.3.6.1.4.1.5504.2.4.1.1.1 |
This variable describes the working status of the four fans
for the Sechtor 100. If any one of the four fans is not
running correctly, this variable shows 'fanFailure'. When
all the fans are working, the value of this variable is
'operational'.
|
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
operational(1), fanFailure(2) |
|
s100ThermoAUpperThreshold |
1.3.6.1.4.1.5504.2.4.1.1.2 |
This variable specifies the upper threshold for thermometer
A in degrees Celsius. When s100ThermoATemperature is
above this value, s100ThermoAOperationalStatus would be
'overUpperThreshold' and a trap will be generated.
Valid range is 45..80 degrees Celsius and the default
is 65 degrees Celsius. |
Status: deprecated |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
45..80 |
|
s100ThermoBUpperThreshold |
1.3.6.1.4.1.5504.2.4.1.1.3 |
This variable specifies the upper threshold for thermometer
B in degrees Celsius. When s100ThermoBTemperature is
above this value, s100ThermoBOperationalStatus would be
'overUpperThreshold' and a trap will be generated.
Valid range is 45..80 degrees Celsius and the default
is 60 degrees Celsius. |
Status: deprecated |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
45..80 |
|
s10ThermoALowerThreshold |
1.3.6.1.4.1.5504.2.4.1.1.4 |
This variable specifies the lower threshold for thermometer
A in degrees Celsius. When s100ThermoATemperature is
below this value, s100ThermoAOperationalStatus would be
'belowLowerThreshold' and a trap will be generated.
Valid range is -10..5 degrees Celsius and the default
is -5 degrees Celsius. |
Status: deprecated |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
-10..5 |
|
s100ThermoBLowerThreshold |
1.3.6.1.4.1.5504.2.4.1.1.5 |
This variable specifies the lower threshold for thermometer
B in degrees Celsius. When s100ThermoATemperature is
below this value, s100ThermoBOperationalStatus would be
'belowLowerThreshold' and a trap will be generated.
Valid range is -10..5 degrees Celsius and the default
is -5 degrees Celsius. |
Status: deprecated |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
-10..5 |
|
s100ThermoATemperature |
1.3.6.1.4.1.5504.2.4.1.1.6 |
The temperature in degrees Celsius read by the IC
thermometer sensor A on the PCB board. It is effectively
the internal ambient temperature inside the enclosure
where thermometer A is located.
The valid temperature range for the thermometer is
-55..125 degrees Celsius. |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
-55..125 |
|
s100ThermoBTemperature |
1.3.6.1.4.1.5504.2.4.1.1.7 |
The temperature in degrees Celsius read by the IC
thermometer sensor B on the PCB board. It is effectively
the internal ambient temperature inside the enclosure
where thermometer B is located.
The valid temperature range for the thermometer is
-55..125 degrees Celsius. |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
-55..125 |
|
s100ThermoAOperationalStatus |
1.3.6.1.4.1.5504.2.4.1.1.8 |
The operational status indicator for thermometer A.
Valid values are:
* withinOperationalRange - s100ThermoATemperature is within
its lower and upper threshold range.
* overUpperThreshold - s100ThermoATemperature is higher
than its upper threshold.
* belowLowerThreshold - s100ThermoATemperature is lower
than its lower threshold. |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
withinOperationalRange(1), overUpperThreshold(2), belowLowerThreshold(3) |
|
s100ThermoBOperationalStatus |
1.3.6.1.4.1.5504.2.4.1.1.9 |
The operational status indicator for thermometer B.
Valid values are:
* withinOperationalRange - s100ThermoBTemperature is within
its lower and upper threshold range.
* overUpperThreshold - s100ThermoBTemperature is higher
than its upper threshold.
* belowLowerThreshold - s100ThermoBTemperature is lower
than its lower threshold. |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
withinOperationalRange(1), overUpperThreshold(2), belowLowerThreshold(3) |
|
sechtor100Traps |
1.3.6.1.4.1.5504.2.4.1.2 |
All Sechtor 100 MIB traps are defined under sechtor100Traps. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
sechtor100TrapsPrefix |
1.3.6.1.4.1.5504.2.4.1.2.0 |
Prefix 0 for Sechtor 100 MIB traps as required by SNMPv2. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
s100FanStatusChange |
1.3.6.1.4.1.5504.2.4.1.2.0.1 |
This trap is generated whenever the value of
s100FanOperationalStatus changes.
This trap is deprecated and is replaced by sechtor100FanStatusChange. |
Status: deprecated |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
s100ThermoStatusChange |
1.3.6.1.4.1.5504.2.4.1.2.0.2 |
This trap is generated whenever sechtor100ThermoAOperationalStatus
or sechtor100ThermoBOperationalStatus changes its value.
This trap is deprecated and is replaced by sechtor100ThermoStatusChange. |
Status: deprecated |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
sechtor100FanStatusChange |
1.3.6.1.4.1.5504.2.4.1.2.0.3 |
This trap is generated whenever the value of
sechtor100FanOperationalStatus changes.
The Sechtor 100 is identified by the shelf and slot number from
instance OID's contained in the trap VarBind objects. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
sechtor100ThermoStatusChange |
1.3.6.1.4.1.5504.2.4.1.2.0.4 |
This trap is generated whenever sechtor100ThermoAOperationalStatus
or sechtor100ThermoBOperationalStatus changes its value.
The Sechtor 100 is identified by the shelf and slot number from
instance OID's contained in the trap VarBind objects. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
sechtor100ConfigTable |
1.3.6.1.4.1.5504.2.4.1.3 |
This table contains redundancy variables and environmental
variables for monitoring fans and thermometers.
For redundancy, the peer MAC address is maintained in this
table. Also, one variable specifies whether redundancy is
enabled or not.
There are two thermometers on the Sechtor 100 board. In this
MIB, thermometers 'A' and 'B' are used to differentiate
these two thermometers:
Thermometer A - the thermometer located near the 750
processor. It is expected that this thermometer have a higher
temperature reading than thermometer B because of the heat
generated by the processor. It is recommended that a higher
upper threshold is set for this thermometer.
Thermometer B - the thermometer located near the outlet on
the right side of the Sechtor 100 board.
The profile for this table will be auto-created as 1/1 with
the sechtor100RedundancyEnable variable set to FALSE.
This profile should not be deleted except for the following
two cases:
1) When a unit operating in simplex mode is intended to be used
in duplex mode as the slot 2 of the redundant system. The
user needs to create a 1/2 profile.
2) The unit configured as slot 2 of a redundant system is intended
to be used in simplex mode. Then the 1/2 profile should be
deleted and replaced with a 1/1 profile. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Sechtor100ConfigEntry |
|
sechtor100ConfigEntry |
1.3.6.1.4.1.5504.2.4.1.3.1 |
An entry in the sechtor100ConfigTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Sechtor100ConfigEntry |
|
|
sechtor100RedundancyEnable |
1.3.6.1.4.1.5504.2.4.1.3.1.2 |
Whether or not the redundancy functionality has been enabled.
If this value is false, redundancy is not enable. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
sechtor100FanOperationalStatus |
1.3.6.1.4.1.5504.2.4.1.3.1.3 |
This variable describes the working status of the four fans
for the Sechtor 100. If any one of the four fans is not
running correctly, this variable shows 'fanFailure'. When
all the fans are working, the value of this variable is
'operational'. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
operational(1), fanFailure(2) |
|
sechtor100ThermoAUpperThreshold |
1.3.6.1.4.1.5504.2.4.1.3.1.4 |
This variable specifies the upper threshold for thermometer
A in degrees Celsius. When s100ThermoATemperature is
above this value, s100ThermoAOperationalStatus would be
'overUpperThreshold' and a trap will be generated.
Valid range is 45..80 degrees Celsius and the default
is 65 degrees Celsius. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
45..80 |
|
sechtor100ThermoBUpperThreshold |
1.3.6.1.4.1.5504.2.4.1.3.1.5 |
This variable specifies the upper threshold for thermometer
B in degrees Celsius. When s100ThermoBTemperature is
above this value, s100ThermoBOperationalStatus would be
'overUpperThreshold' and a trap will be generated.
Valid range is 45..80 degrees Celsius and the default
is 60 degrees Celsius. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
45..80 |
|
sechtor100ThermoALowerThreshold |
1.3.6.1.4.1.5504.2.4.1.3.1.6 |
This variable specifies the lower threshold for thermometer
A in degrees Celsius. When s100ThermoATemperature is
below this value, s100ThermoAOperationalStatus would be
'belowLowerThreshold' and a trap will be generated.
Valid range is -10..5 degrees Celsius and the default
is -5 degrees Celsius. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
-10..5 |
|
sechtor100ThermoBLowerThreshold |
1.3.6.1.4.1.5504.2.4.1.3.1.7 |
This variable specifies the lower threshold for thermometer
B in degrees Celsius. When s100ThermoATemperature is
below this value, s100ThermoBOperationalStatus would be
'belowLowerThreshold' and a trap will be generated.
Valid range is -10..5 degrees Celsius and the default
is -5 degrees Celsius. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
-10..5 |
|
sechtor100ThermoATemperature |
1.3.6.1.4.1.5504.2.4.1.3.1.8 |
The temperature in degrees Celsius read by the IC
thermometer sensor A on the PCB board. It is effectively
the internal ambient temperature inside the enclosure
where thermometer A is located.
The valid temperature range for the thermometer is
-55..125 degrees Celsius. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
-55..125 |
|
sechtor100ThermoBTemperature |
1.3.6.1.4.1.5504.2.4.1.3.1.9 |
The temperature in degrees Celsius read by the IC
thermometer sensor B on the PCB board. It is effectively
the internal ambient temperature inside the enclosure
where thermometer B is located.
The valid temperature range for the thermometer is
-55..125 degrees Celsius. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
-55..125 |
|
sechtor100ThermoAOperationalStatus |
1.3.6.1.4.1.5504.2.4.1.3.1.10 |
The operational status indicator for thermometer A.
Valid values are:
* withinOperationalRange - s100ThermoATemperature is within
its lower and upper threshold range.
* overUpperThreshold - s100ThermoATemperature is higher
than its upper threshold.
* belowLowerThreshold - s100ThermoATemperature is lower
than its lower threshold. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
withinOperationalRange(1), overUpperThreshold(2), belowLowerThreshold(3) |
|
sechtor100ThermoBOperationalStatus |
1.3.6.1.4.1.5504.2.4.1.3.1.11 |
The operational status indicator for thermometer B.
Valid values are:
* withinOperationalRange - s100ThermoBTemperature is within
its lower and upper threshold range.
* overUpperThreshold - s100ThermoBTemperature is higher
than its upper threshold.
* belowLowerThreshold - s100ThermoBTemperature is lower
than its lower threshold. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
withinOperationalRange(1), overUpperThreshold(2), belowLowerThreshold(3) |
|
sechtor100RowStatus |
1.3.6.1.4.1.5504.2.4.1.3.1.12 |
Used to control row creation and deletion.
A row in this table is created using a single
SNMP SET request with varbinds for:
a) sechtor100RowStatus set to'CreateAndGo',
b) the following READ-CREATE object(s):
*
If 'createAndGo' successfully created a new row,
the RowStatus will be 'active'. Subsequent to
successful row creation, the RowStatus can be
retrieved via an SNMP GET and the returned
RowStatus value is active. If the 'createAndGo'
was unsuccessful an SNMP error will be returned
and a subsequent GET on the non-existent row
will also return an SNMP error of noSuchInstance.
An SNMP SET with the RowStatus value of 'destroy'
indicates that the agent should remove the row
from service and then delete it. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
ZhoneRowStatus |
|
|