ZHONE-SECHTOR100-MIB

File: ZHONE-SECHTOR100-MIB.mib (23717 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC Zhone
Zhone-TC

Imported symbols

Integer32 OBJECT-TYPE MODULE-IDENTITY
OBJECT-IDENTITY NOTIFICATION-TYPE MacAddress
TruthValue sechtor100 zhoneModules
zhoneShelfIndex zhoneSlotIndex ZhoneRowStatus

Defined Types

Sechtor100ConfigEntry  
SEQUENCE    
  sechtor100PeerMacAddress MacAddress
  sechtor100RedundancyEnable TruthValue
  sechtor100FanOperationalStatus INTEGER
  sechtor100ThermoAUpperThreshold Integer32
  sechtor100ThermoBUpperThreshold Integer32
  sechtor100ThermoALowerThreshold Integer32
  sechtor100ThermoBLowerThreshold Integer32
  sechtor100ThermoATemperature Integer32
  sechtor100ThermoBTemperature Integer32
  sechtor100ThermoAOperationalStatus INTEGER
  sechtor100ThermoBOperationalStatus INTEGER
  sechtor100RowStatus ZhoneRowStatus

Defined Values

zhoneSechtor100 1.3.6.1.4.1.5504.6.19
MIB module for elements specific to Sechtor 100 products.
MODULE-IDENTITY    

sechtor100Environment 1.3.6.1.4.1.5504.2.4.1.1
All the scalar objects under sechor100Environment are deprecated and replaced by their respective objects indexed by zhoneShelfIndex and zhoneSlotIndex.
Status: deprecated Access: read-only
OBJECT-IDENTITY    

s100FanOperationalStatus 1.3.6.1.4.1.5504.2.4.1.1.1
This variable describes the working status of the four fans for the Sechtor 100. If any one of the four fans is not running correctly, this variable shows 'fanFailure'. When all the fans are working, the value of this variable is 'operational'.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER operational(1), fanFailure(2)  

s100ThermoAUpperThreshold 1.3.6.1.4.1.5504.2.4.1.1.2
This variable specifies the upper threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is above this value, s100ThermoAOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 65 degrees Celsius.
Status: deprecated Access: read-write
OBJECT-TYPE    
  Integer32 45..80  

s100ThermoBUpperThreshold 1.3.6.1.4.1.5504.2.4.1.1.3
This variable specifies the upper threshold for thermometer B in degrees Celsius. When s100ThermoBTemperature is above this value, s100ThermoBOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 60 degrees Celsius.
Status: deprecated Access: read-write
OBJECT-TYPE    
  Integer32 45..80  

s10ThermoALowerThreshold 1.3.6.1.4.1.5504.2.4.1.1.4
This variable specifies the lower threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoAOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius.
Status: deprecated Access: read-write
OBJECT-TYPE    
  Integer32 -10..5  

s100ThermoBLowerThreshold 1.3.6.1.4.1.5504.2.4.1.1.5
This variable specifies the lower threshold for thermometer B in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoBOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius.
Status: deprecated Access: read-write
OBJECT-TYPE    
  Integer32 -10..5  

s100ThermoATemperature 1.3.6.1.4.1.5504.2.4.1.1.6
The temperature in degrees Celsius read by the IC thermometer sensor A on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer A is located. The valid temperature range for the thermometer is -55..125 degrees Celsius.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32 -55..125  

s100ThermoBTemperature 1.3.6.1.4.1.5504.2.4.1.1.7
The temperature in degrees Celsius read by the IC thermometer sensor B on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer B is located. The valid temperature range for the thermometer is -55..125 degrees Celsius.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32 -55..125  

s100ThermoAOperationalStatus 1.3.6.1.4.1.5504.2.4.1.1.8
The operational status indicator for thermometer A. Valid values are: * withinOperationalRange - s100ThermoATemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoATemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoATemperature is lower than its lower threshold.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER withinOperationalRange(1), overUpperThreshold(2), belowLowerThreshold(3)  

s100ThermoBOperationalStatus 1.3.6.1.4.1.5504.2.4.1.1.9
The operational status indicator for thermometer B. Valid values are: * withinOperationalRange - s100ThermoBTemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoBTemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoBTemperature is lower than its lower threshold.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER withinOperationalRange(1), overUpperThreshold(2), belowLowerThreshold(3)  

sechtor100Traps 1.3.6.1.4.1.5504.2.4.1.2
All Sechtor 100 MIB traps are defined under sechtor100Traps.
Status: current Access: read-only
OBJECT-IDENTITY    

sechtor100TrapsPrefix 1.3.6.1.4.1.5504.2.4.1.2.0
Prefix 0 for Sechtor 100 MIB traps as required by SNMPv2.
Status: current Access: read-only
OBJECT-IDENTITY    

s100FanStatusChange 1.3.6.1.4.1.5504.2.4.1.2.0.1
This trap is generated whenever the value of s100FanOperationalStatus changes. This trap is deprecated and is replaced by sechtor100FanStatusChange.
Status: deprecated Access: read-only
NOTIFICATION-TYPE    

s100ThermoStatusChange 1.3.6.1.4.1.5504.2.4.1.2.0.2
This trap is generated whenever sechtor100ThermoAOperationalStatus or sechtor100ThermoBOperationalStatus changes its value. This trap is deprecated and is replaced by sechtor100ThermoStatusChange.
Status: deprecated Access: read-only
NOTIFICATION-TYPE    

sechtor100FanStatusChange 1.3.6.1.4.1.5504.2.4.1.2.0.3
This trap is generated whenever the value of sechtor100FanOperationalStatus changes. The Sechtor 100 is identified by the shelf and slot number from instance OID's contained in the trap VarBind objects.
Status: current Access: read-only
NOTIFICATION-TYPE    

sechtor100ThermoStatusChange 1.3.6.1.4.1.5504.2.4.1.2.0.4
This trap is generated whenever sechtor100ThermoAOperationalStatus or sechtor100ThermoBOperationalStatus changes its value. The Sechtor 100 is identified by the shelf and slot number from instance OID's contained in the trap VarBind objects.
Status: current Access: read-only
NOTIFICATION-TYPE    

sechtor100ConfigTable 1.3.6.1.4.1.5504.2.4.1.3
This table contains redundancy variables and environmental variables for monitoring fans and thermometers. For redundancy, the peer MAC address is maintained in this table. Also, one variable specifies whether redundancy is enabled or not. There are two thermometers on the Sechtor 100 board. In this MIB, thermometers 'A' and 'B' are used to differentiate these two thermometers: Thermometer A - the thermometer located near the 750 processor. It is expected that this thermometer have a higher temperature reading than thermometer B because of the heat generated by the processor. It is recommended that a higher upper threshold is set for this thermometer. Thermometer B - the thermometer located near the outlet on the right side of the Sechtor 100 board. The profile for this table will be auto-created as 1/1 with the sechtor100RedundancyEnable variable set to FALSE. This profile should not be deleted except for the following two cases: 1) When a unit operating in simplex mode is intended to be used in duplex mode as the slot 2 of the redundant system. The user needs to create a 1/2 profile. 2) The unit configured as slot 2 of a redundant system is intended to be used in simplex mode. Then the 1/2 profile should be deleted and replaced with a 1/1 profile.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sechtor100ConfigEntry

sechtor100ConfigEntry 1.3.6.1.4.1.5504.2.4.1.3.1
An entry in the sechtor100ConfigTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  Sechtor100ConfigEntry  

sechtor100PeerMacAddress 1.3.6.1.4.1.5504.2.4.1.3.1.1
This is the Mac address of the peer s100 unit.
Status: current Access: read-write
OBJECT-TYPE    
  MacAddress  

sechtor100RedundancyEnable 1.3.6.1.4.1.5504.2.4.1.3.1.2
Whether or not the redundancy functionality has been enabled. If this value is false, redundancy is not enable.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

sechtor100FanOperationalStatus 1.3.6.1.4.1.5504.2.4.1.3.1.3
This variable describes the working status of the four fans for the Sechtor 100. If any one of the four fans is not running correctly, this variable shows 'fanFailure'. When all the fans are working, the value of this variable is 'operational'.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER operational(1), fanFailure(2)  

sechtor100ThermoAUpperThreshold 1.3.6.1.4.1.5504.2.4.1.3.1.4
This variable specifies the upper threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is above this value, s100ThermoAOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 65 degrees Celsius.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 45..80  

sechtor100ThermoBUpperThreshold 1.3.6.1.4.1.5504.2.4.1.3.1.5
This variable specifies the upper threshold for thermometer B in degrees Celsius. When s100ThermoBTemperature is above this value, s100ThermoBOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 60 degrees Celsius.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 45..80  

sechtor100ThermoALowerThreshold 1.3.6.1.4.1.5504.2.4.1.3.1.6
This variable specifies the lower threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoAOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -10..5  

sechtor100ThermoBLowerThreshold 1.3.6.1.4.1.5504.2.4.1.3.1.7
This variable specifies the lower threshold for thermometer B in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoBOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -10..5  

sechtor100ThermoATemperature 1.3.6.1.4.1.5504.2.4.1.3.1.8
The temperature in degrees Celsius read by the IC thermometer sensor A on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer A is located. The valid temperature range for the thermometer is -55..125 degrees Celsius.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -55..125  

sechtor100ThermoBTemperature 1.3.6.1.4.1.5504.2.4.1.3.1.9
The temperature in degrees Celsius read by the IC thermometer sensor B on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer B is located. The valid temperature range for the thermometer is -55..125 degrees Celsius.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -55..125  

sechtor100ThermoAOperationalStatus 1.3.6.1.4.1.5504.2.4.1.3.1.10
The operational status indicator for thermometer A. Valid values are: * withinOperationalRange - s100ThermoATemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoATemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoATemperature is lower than its lower threshold.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER withinOperationalRange(1), overUpperThreshold(2), belowLowerThreshold(3)  

sechtor100ThermoBOperationalStatus 1.3.6.1.4.1.5504.2.4.1.3.1.11
The operational status indicator for thermometer B. Valid values are: * withinOperationalRange - s100ThermoBTemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoBTemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoBTemperature is lower than its lower threshold.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER withinOperationalRange(1), overUpperThreshold(2), belowLowerThreshold(3)  

sechtor100RowStatus 1.3.6.1.4.1.5504.2.4.1.3.1.12
Used to control row creation and deletion. A row in this table is created using a single SNMP SET request with varbinds for: a) sechtor100RowStatus set to'CreateAndGo', b) the following READ-CREATE object(s): * If 'createAndGo' successfully created a new row, the RowStatus will be 'active'. Subsequent to successful row creation, the RowStatus can be retrieved via an SNMP GET and the returned RowStatus value is active. If the 'createAndGo' was unsuccessful an SNMP error will be returned and a subsequent GET on the non-existent row will also return an SNMP error of noSuchInstance. An SNMP SET with the RowStatus value of 'destroy' indicates that the agent should remove the row from service and then delete it.
Status: current Access: read-create
OBJECT-TYPE    
  ZhoneRowStatus