ZHNSYSTEM

File: ZHNSYSTEM.mib (80304 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
Zhone Zhone-TC

Imported symbols

MODULE-IDENTITY OBJECT-TYPE enterprises
Integer32 Unsigned32 IpAddress
MODULE-COMPLIANCE OBJECT-GROUP TEXTUAL-CONVENTION
DisplayString MacAddress RowStatus
TruthValue zhoneWtn ZhoneRowStatus

Defined Types

WFNT  
The Wifi Network Type
TEXTUAL-CONVENTION    
  INTEGER notApplicable(0), baseStation(1), mesh(2)  

ELTYPE  
Ethernet Like Interface Type
TEXTUAL-CONVENTION    
  INTEGER ethernet(1), efm(2), shdsl(3), docsis(4), wimax(5)  

ELSUBTYPE  
Ethernet Like Interface Sub-Type
TEXTUAL-CONVENTION    
  INTEGER none(0)  

LPT  
Line Power Direction
TEXTUAL-CONVENTION    
  INTEGER none(0), in(1), out(2)  

UPT  
Unit Power Supply Type
TEXTUAL-CONVENTION    
  INTEGER ac(1), dc(2)  

TCSI  
Transmit Clock Source Items
TEXTUAL-CONVENTION    
  INTEGER notApplicable(0), loop(1), local(2), pwe(3)  

LTRI  
Local Timing Reference Items
TEXTUAL-CONVENTION    
  INTEGER notApplicable(0), ethernet(1), internal(2), shdsl(3)  

CSMI  
Pseudo Wire Clock Synchronization Mode Items
TEXTUAL-CONVENTION    
  INTEGER notApplicable(0), adaptive(1), differential(2), synchronous(3), dslAdaptive(4), loop(5)  

SEI  
Synchronous Ethernet Items
TEXTUAL-CONVENTION    
  INTEGER enable(1), disable(2)  

CMI  
Clock Mode Items
TEXTUAL-CONVENTION    
  INTEGER notApplicable(0), normal(1), differential(2)  

CDA  
Configuration Database Action
TEXTUAL-CONVENTION    
  INTEGER noAction(0), save(1), resetToDefaults(2)  

RBT  
Software Reboot Action
TEXTUAL-CONVENTION    
  INTEGER noAction(0), reboot(1)  

SCS  
System Clock Source Items
TEXTUAL-CONVENTION    
  INTEGER notApplicable(0), uplink(1), ds1(2), ieee1588(3)  

ETCS  
Ethernet Transmit Clock Source Items
TEXTUAL-CONVENTION    
  INTEGER notApplicable(0), internal(1), systemClock(2)  

SysFirmwareAction  
Action to take on the current firmware version.
TEXTUAL-CONVENTION    
  INTEGER noAction(0), restoreAltFirmware(1)  

SysAdminStatus  
Administrative status options for various system services, like syslog and power-shedding.
TEXTUAL-CONVENTION    
  INTEGER enable(1), disable(2)  

SysLogLevel  
SysLog logging level options, per RFC 3164.
TEXTUAL-CONVENTION    
  INTEGER emergency(0), alert(1), critical(2), error(3), warning(4), notice(5), informational(6), debug(7)  

SysLogMode  
SysLog logging mode of operation.
TEXTUAL-CONVENTION    
  INTEGER local(1), remote(2), both(3)  

SysSntpTimeZones  
Simple Network Timing Protocol time zones.
TEXTUAL-CONVENTION    
  INTEGER unknown(0), abu(1), adelaide(2), alaska(3), almaty(4), amsterdam(5), arizona(6), astana(7), athens(8), atlantic(9), auckland(10), azores(11), baghdad(12), baku(13), bangkok(14), beijing(15), belgrade(16), bogota(17), brasilia(18), brisbane(19), brussels(20), bucharest(21), buenos(22), cairo(23), canberra(24), cape(25), caracas(26), casablanca(27), central(28), centraltime(29), chennai(30), chihuahua(31), darwin(32), eastern(33), ekaterinburg(34), fiji(35), greenland(36), greenwich(37), guadalajara(38), guam(39), harare(40), hawaii(41), helsinki(42), hobart(43), indiana(44), international(45), irkutsk(46), islamabad(47), jerusalem(48), kabul(49), kathmandu(50), krasnoyarsk(51), kuala(52), kuwait(53), magadan(54), midatlantic(55), midway(56), moscow(57), mountain(58), nairobi(59), newfoundland(60), osaka(61), pacific(62), perth(63), rangoon(64), santiago(65), sarajevo(66), saskatchewan(67), seoul(68), solomon(69), sri(70), taipei(71), tehran(72), vladivostok(73), west(74), yakutsk(75)  

IPInterfaceAddressingTypeValues  
The addressing method used to assign the LAN-side IP Address. Enumeration of: Unknown Unconfigured Default DHCP Static PPPoE OMCI
TEXTUAL-CONVENTION    
  OCTET STRING Size(0..32)  

BasicAddressingTypeValues  
Enumeration of: DHCP - The DNS information is obtained via DHCP Static - The DNS information is manually provisioned
TEXTUAL-CONVENTION    
  OCTET STRING Size(0..16)  

BoardDescriptorEntry  
SEQUENCE    
  boardIndex Unsigned32
  boardName DisplayString
  boardPartNumber DisplayString
  boardSerialNumber DisplayString
  boardRevision DisplayString

PldDescriptorEntry  
SEQUENCE    
  pldIndex Unsigned32
  pldName DisplayString
  pldVersion DisplayString

EthernetlikeInterfaceEntry  
SEQUENCE    
  etherIndex Unsigned32
  etherName DisplayString
  etherType ELTYPE
  etherSubtype ELSUBTYPE
  etherNumberOfPorts Unsigned32
  etherLinePower LPT
  etherPowerPairs Integer32

TemperatureSensorEntry  
SEQUENCE    
  temperatureSensorIndex Unsigned32
  temperatureSensorName DisplayString
  temperatureSensorMaximum DisplayString
  temperatureSensorMinimum DisplayString

ZhnCommunityTableEntry  
SEQUENCE    
  communityName DisplayString
  communityType INTEGER
  communityRowStatus RowStatus

ZhnTrapManagerInfoTableEntry  
SEQUENCE    
  trapDestination IpAddress
  trapCommunityName DisplayString
  trapVersion INTEGER
  trapPort INTEGER
  trapRowStatus RowStatus

ZhnFixedCommunityTableEntry  
SEQUENCE    
  fixedCommunityName DisplayString
  fixedCommunityType INTEGER
  fixedCommunityRowStatus RowStatus

ZhnDnsProxyHostEntry  
SEQUENCE    
  dnsProxyHostIndex Unsigned32
  dnsProxyHostIPAddress IpAddress
  dnsProxyHostName OCTET STRING
  dnsProxyRowStatus ZhoneRowStatus

Defined Values

zhnSystem 1.3.6.1.4.1.5504.2.5.2
This file defines the private Enterprise MIB extensions that define system related objects. ============================================================== == == == Copyright (C) 2008-2012 Zhone Technologies, Inc. == == == ==============================================================
MODULE-IDENTITY    

zhnSystemObjects 1.3.6.1.4.1.5504.2.5.2.1
OBJECT IDENTIFIER    

zhnSystemGeneralObjects 1.3.6.1.4.1.5504.2.5.2.1.1
OBJECT IDENTIFIER    

zhnSystemBoardObjects 1.3.6.1.4.1.5504.2.5.2.1.2
OBJECT IDENTIFIER    

zhnSystemPldObjects 1.3.6.1.4.1.5504.2.5.2.1.3
OBJECT IDENTIFIER    

zhnSystemRadioObjects 1.3.6.1.4.1.5504.2.5.2.1.4
OBJECT IDENTIFIER    

zhnSystemEthernetLikeObjects 1.3.6.1.4.1.5504.2.5.2.1.5
OBJECT IDENTIFIER    

zhnSystemTempSensorObjects 1.3.6.1.4.1.5504.2.5.2.1.6
OBJECT IDENTIFIER    

zhnSystemSNMPObjects 1.3.6.1.4.1.5504.2.5.2.1.7
OBJECT IDENTIFIER    

zhnSystemTrapObjects 1.3.6.1.4.1.5504.2.5.2.1.8
OBJECT IDENTIFIER    

zhnSystemSyslogObjects 1.3.6.1.4.1.5504.2.5.2.1.9
OBJECT IDENTIFIER    

zhnSystemSNTPObjects 1.3.6.1.4.1.5504.2.5.2.1.10
OBJECT IDENTIFIER    

zhnSystemUserLoginObjects 1.3.6.1.4.1.5504.2.5.2.1.11
OBJECT IDENTIFIER    

zhnSystemPowerSheddingObjects 1.3.6.1.4.1.5504.2.5.2.1.12
OBJECT IDENTIFIER    

zhnSystemFirewallObjects 1.3.6.1.4.1.5504.2.5.2.1.13
OBJECT IDENTIFIER    

zhnSystemDNSClientObjects 1.3.6.1.4.1.5504.2.5.2.1.14
OBJECT IDENTIFIER    

zhnSystemDNSProxyObjects 1.3.6.1.4.1.5504.2.5.2.1.15
OBJECT IDENTIFIER    

zhnSystemWanBackupObjects 1.3.6.1.4.1.5504.2.5.2.1.16
OBJECT IDENTIFIER    

zhnSystemTr69cObjects 1.3.6.1.4.1.5504.2.5.2.1.17
OBJECT IDENTIFIER    

modelNumber 1.3.6.1.4.1.5504.2.5.2.1.1.1
model no. of the device
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

macBaseAddress 1.3.6.1.4.1.5504.2.5.2.1.1.2
First MAC Address in series
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

numberOfMacAddresses 1.3.6.1.4.1.5504.2.5.2.1.1.3
Number of MAC Address sequentially defined in the Unit starting at the MAC Base Address.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..10  

wifiNetworkType 1.3.6.1.4.1.5504.2.5.2.1.1.4
Defines the Network Type or Mode of the Unit, i.e. Mesh or Base Station
Status: current Access: read-write
OBJECT-TYPE    
  WFNT  

locationLatitude 1.3.6.1.4.1.5504.2.5.2.1.1.6
The latitude of the unit's location represented in degrees decimal. The format of the location's latitude is: [+ | -]ddd.dddddddd where + indicates north - indicates south d is a decimal digit (0 <= d <= 9) Valid range is -90 to +90 degrees.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

locationLongitude 1.3.6.1.4.1.5504.2.5.2.1.1.7
The longitude of the unit's location represented in degrees decimal. The format of the location's longitude is: [+ | -]ddd.dddddddd where + indicates east - indicates west d is a decimal digit (0 <= d <= 9) Valid range is -180 to +180 degrees.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

zhnSystemAction 1.3.6.1.4.1.5504.2.5.2.1.1.8
Action parameter to handle the action on other scalars.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

zhnSysLocation 1.3.6.1.4.1.5504.2.5.2.1.1.9
System location. This object is synonomous with the MIB II system sysLocation object.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

zhnSysContact 1.3.6.1.4.1.5504.2.5.2.1.1.10
System contact. This object is synonomous with the MIB II system sysContact object.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sysTransmitClockSource 1.3.6.1.4.1.5504.2.5.2.1.1.11
T1 Clock source for PWE device. Since both T1/E1 interfaces will be required to have the same source, this object will replace the dsx1TransmitClockSource object in the DS1-MIB. This object is not supported by ZNID devices.
Status: current Access: read-write
OBJECT-TYPE    
  TCSI  

sysLocalTimingReference 1.3.6.1.4.1.5504.2.5.2.1.1.12
Source of the sysTransmitClockSource when set to Local. This object is not supported by ZNID devices.
Status: current Access: read-write
OBJECT-TYPE    
  LTRI  

sysSynchronizationMode 1.3.6.1.4.1.5504.2.5.2.1.1.13
Determines the method of ensuring Service Clock synchronization between the Source and Remote PWE devices.
Status: current Access: read-write
OBJECT-TYPE    
  CSMI  

sysSynchronousEthernet 1.3.6.1.4.1.5504.2.5.2.1.1.14
Determines whether or not to use the 25MHz clock derived from the Synchronous Ethernet Port. This object is not supported by ZNID devices.
Status: current Access: read-write
OBJECT-TYPE    
  SEI  

sysClockMode 1.3.6.1.4.1.5504.2.5.2.1.1.15
Determines the mode for which the PWE chip will be initialized.
Status: current Access: read-write
OBJECT-TYPE    
  CMI  

sysCfgDBAction 1.3.6.1.4.1.5504.2.5.2.1.1.16
Perform an action on the configuration database.
Status: current Access: read-write
OBJECT-TYPE    
  CDA  

sysSoftwareReboot 1.3.6.1.4.1.5504.2.5.2.1.1.17
Perform a software reboot.
Status: current Access: read-write
OBJECT-TYPE    
  RBT  

sysSystemClockSource 1.3.6.1.4.1.5504.2.5.2.1.1.18
Determines the system-level clock mode for ZNID devices. uplink - the system will recover its clock from the configured uplink (e.g. GPON, SPF1, SFP2, etc.). ds1 - the system will recover its clock from the configured sysDs1ClockSourcePort. ieee1588 - the system will recover clock from the on-board 1588 clock circuitry.
Status: current Access: read-write
OBJECT-TYPE    
  SCS  

sysEthernetTransmitClockSource 1.3.6.1.4.1.5504.2.5.2.1.1.19
Determines the transmit clock source for all ethernet ports requiring a clock. internal - all ethernet ports will recover clock from the local oscillator. systemClock - all ethernet ports will recover clock from the sysSystemClockSource.
Status: current Access: read-write
OBJECT-TYPE    
  ETCS  

sysDs1ClockSourcePort 1.3.6.1.4.1.5504.2.5.2.1.1.20
The interface name for the DS1 port providing transmit clock when the sysSystemClockSource is set to ds1.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sysBootloaderVersion 1.3.6.1.4.1.5504.2.5.2.1.1.21
System bootloader (CFE) firmware version.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..64)  

sysFirmwareVersion 1.3.6.1.4.1.5504.2.5.2.1.1.22
The version of firmware the system is currently running.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..64)  

sysAltFirmwareVersion 1.3.6.1.4.1.5504.2.5.2.1.1.23
The alternate firmware version currently stored in system flash.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..64)  

sysRestoreAltFirmwareVersion 1.3.6.1.4.1.5504.2.5.2.1.1.24
This object can be used to restore the version of firmware to the alternate firmware version currently stored in flash.
Status: current Access: read-write
OBJECT-TYPE    
  SysFirmwareAction  

sysSnmpProvisioningLock 1.3.6.1.4.1.5504.2.5.2.1.1.25
This object can be set by an SNMP client to indicate that system configuration is in progress. All other SNMP clients will be locked out while this is set to true. This lock will timeout after 30 seconds.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

sysSnmpProvisioningChange 1.3.6.1.4.1.5504.2.5.2.1.1.26
This object can be incremented by SNMP clients to indicate a sysCfgDBAction save has taken place.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

numberOfBoards 1.3.6.1.4.1.5504.2.5.2.1.2.1
Number of boards in the Unit with Name, Part Number, Serial Number and Revision Number values
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4  

boardDescriptorTable 1.3.6.1.4.1.5504.2.5.2.1.2.2
Table of boards: Name, Part Number, Serial Number and Revision Number values
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BoardDescriptorEntry

boardDescriptorEntry 1.3.6.1.4.1.5504.2.5.2.1.2.2.1
Table of boards: Name, Part Number, Serial Number and Revision Number values
Status: current Access: not-accessible
OBJECT-TYPE    
  BoardDescriptorEntry  

boardIndex 1.3.6.1.4.1.5504.2.5.2.1.2.2.1.1
Board Index (Zero relative)
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..20  

boardName 1.3.6.1.4.1.5504.2.5.2.1.2.2.1.2
Name of the Board as created by the system
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

boardPartNumber 1.3.6.1.4.1.5504.2.5.2.1.2.2.1.3
Part Number of the Board. Read from the board
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

boardSerialNumber 1.3.6.1.4.1.5504.2.5.2.1.2.2.1.4
Serial Number of the Board. Read from the board
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

boardRevision 1.3.6.1.4.1.5504.2.5.2.1.2.2.1.5
Revision Number of the Board. Read from the board
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

numberOfPlds 1.3.6.1.4.1.5504.2.5.2.1.3.1
Number of PLDs in the Unit with Name and Version Number values
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..20  

pldDescriptorTable 1.3.6.1.4.1.5504.2.5.2.1.3.2
Table of boards: Name, Part Number, Serial Number and Revision Number values
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PldDescriptorEntry

pldDescriptorEntry 1.3.6.1.4.1.5504.2.5.2.1.3.2.1
Table of boards: Name, Part Number, Serial Number and Revision Number values
Status: current Access: not-accessible
OBJECT-TYPE    
  PldDescriptorEntry  

pldIndex 1.3.6.1.4.1.5504.2.5.2.1.3.2.1.1
PLD Index (Zero relative)
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..20  

pldName 1.3.6.1.4.1.5504.2.5.2.1.3.2.1.2
Name of the PLD as created by the system
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

pldVersion 1.3.6.1.4.1.5504.2.5.2.1.3.2.1.3
PLD Software Version. Read from the PLD
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

numberOfRadios 1.3.6.1.4.1.5504.2.5.2.1.4.1
Number of Radios in the Unit
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..20  

numberOfEthernetLikeInterfaces 1.3.6.1.4.1.5504.2.5.2.1.5.1
Number of Ethernet Like Interfaces with Name, Type and Subtype
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..20  

ethernetlikeInterfaceTable 1.3.6.1.4.1.5504.2.5.2.1.5.2
Table of ethernet-like Interfaces
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthernetlikeInterfaceEntry

ethernetlikeInterfaceEntry 1.3.6.1.4.1.5504.2.5.2.1.5.2.1
Table of ethernet-like interfaces having Name, type, subtype, number of ports, line power and number of pairs with power
Status: current Access: not-accessible
OBJECT-TYPE    
  EthernetlikeInterfaceEntry  

etherIndex 1.3.6.1.4.1.5504.2.5.2.1.5.2.1.1
Index of the Ethernet Like Interface (zero relative)
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..20  

etherName 1.3.6.1.4.1.5504.2.5.2.1.5.2.1.2
Name of the ethernet Like Interface as created by the system
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

etherType 1.3.6.1.4.1.5504.2.5.2.1.5.2.1.3
Type of Ethernet interface
Status: current Access: read-only
OBJECT-TYPE    
  ELTYPE  

etherSubtype 1.3.6.1.4.1.5504.2.5.2.1.5.2.1.4
Subtype of Ethernet interface
Status: current Access: read-only
OBJECT-TYPE    
  ELSUBTYPE  

etherNumberOfPorts 1.3.6.1.4.1.5504.2.5.2.1.5.2.1.5
Number of Ports on the Ethernet interface
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..400  

etherLinePower 1.3.6.1.4.1.5504.2.5.2.1.5.2.1.6
Line Power Type on this Ethernet Interface
Status: current Access: read-only
OBJECT-TYPE    
  LPT  

etherPowerPairs 1.3.6.1.4.1.5504.2.5.2.1.5.2.1.7
Number of line Pairs providing power on the Ethernet interface
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

numberOfTemperatureSensors 1.3.6.1.4.1.5504.2.5.2.1.6.1
Number of Temperature Sensors in the Unit
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..20  

temperatureSensorTable 1.3.6.1.4.1.5504.2.5.2.1.6.2
Table of Temperature Sensors: Name, Maximum, and Minimum values
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TemperatureSensorEntry

temperatureSensorEntry 1.3.6.1.4.1.5504.2.5.2.1.6.2.1
Table of Temperature Sensors: Name, Maximum, and Minimum values
Status: current Access: not-accessible
OBJECT-TYPE    
  TemperatureSensorEntry  

temperatureSensorIndex 1.3.6.1.4.1.5504.2.5.2.1.6.2.1.1
Temperature Sensor Index (Zero relative)
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..20  

temperatureSensorName 1.3.6.1.4.1.5504.2.5.2.1.6.2.1.2
Name of the ethernet Like Interface as created by the system
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

temperatureSensorMaximum 1.3.6.1.4.1.5504.2.5.2.1.6.2.1.3
Maximum Temperature Recorded
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

temperatureSensorMinimum 1.3.6.1.4.1.5504.2.5.2.1.6.2.1.4
Minimum Temperature Recorded
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerSupplyType 1.3.6.1.4.1.5504.2.5.2.1.1.5
Type of Power Supply that the unit is using
Status: current Access: read-only
OBJECT-TYPE    
  UPT  

numberOfCommunities 1.3.6.1.4.1.5504.2.5.2.1.7.1
Number of SNMP Communities configured in the Unit
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..9999  

zhnCommunityTable 1.3.6.1.4.1.5504.2.5.2.1.7.2
This table is used to set the various configuration parameters for a particular community.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhnCommunityTableEntry

zhnCommunityTableEntry 1.3.6.1.4.1.5504.2.5.2.1.7.2.1
This object corresponds to an entry in the community table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhnCommunityTableEntry  

communityName 1.3.6.1.4.1.5504.2.5.2.1.7.2.1.1
This object corresponds to the SNMP community string.
Status: current Access: not-accessible
OBJECT-TYPE    
  DisplayString  

communityType 1.3.6.1.4.1.5504.2.5.2.1.7.2.1.2
The access type of the community string. The default value of this object should be read-only(1).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER readOnly(1), readWrite(2)  

communityRowStatus 1.3.6.1.4.1.5504.2.5.2.1.7.2.1.3
When written, this object can be used to createAndGo(4) or destroy(6) a row from the table. A rowStatus value of notInService(2) will also destroy a row. RowStatus values of active(1), notReady(3), and createAndWait(5) are ignored.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

numberOfTrapManagers 1.3.6.1.4.1.5504.2.5.2.1.8.1
Number of Trap Managers configured in the Unit
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..9999  

zhnDefaultTrapCommunity 1.3.6.1.4.1.5504.2.5.2.1.8.2
This object corresponds to the default trap community string. The default trap community string will be used when a community name is not configured for a particular trap manager.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

zhnTrapTypeLinkUpDown 1.3.6.1.4.1.5504.2.5.2.1.8.3
Enable or disable all link up/down traps.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

zhnTrapTypeAuthFailure 1.3.6.1.4.1.5504.2.5.2.1.8.4
Enable or disable the generation of authorization failure traps.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

zhnTrapTypeConfigChange 1.3.6.1.4.1.5504.2.5.2.1.8.5
Enable or disable the generation of configuration change traps. This object is not supported by ZNID devices. Rather, the only mechanism to disable the generation of configuration change traps in a ZNID device is to disable the generation of all enterprise traps via the zhnTrapTypeEnterpise object.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

zhnTrapManagerInfoTable 1.3.6.1.4.1.5504.2.5.2.1.8.6
This table is used to set the trap destination address for a particular community.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhnTrapManagerInfoTableEntry

zhnTrapManagerInfoTableEntry 1.3.6.1.4.1.5504.2.5.2.1.8.6.1
This object corresponds to an entry in the community trap address info table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhnTrapManagerInfoTableEntry  

trapDestination 1.3.6.1.4.1.5504.2.5.2.1.8.6.1.1
The IP Address of the destination to which a trap must be sent.
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAddress  

trapCommunityName 1.3.6.1.4.1.5504.2.5.2.1.8.6.1.2
This object corresponds to the trap community string. If not specified, the trapCommunityName will be set to the zhnDefaultTrapCommunity object.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

trapVersion 1.3.6.1.4.1.5504.2.5.2.1.8.6.1.3
The trap types automatically supported by net-snmp and enabled/disabled in snmpd.conf. If not specified, the trapVersion will be set the default value of v2c.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER v1(1), v2c(2)  

trapPort 1.3.6.1.4.1.5504.2.5.2.1.8.6.1.4
The udp/tcp port number to which a trap must be sent. If not specified, the trapPort will be set the default value of 162.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..65536  

trapRowStatus 1.3.6.1.4.1.5504.2.5.2.1.8.6.1.5
When written, this object can be used to createAndGo(4) or destroy(6) a row from the table. A rowStatus value of notInService(2) will also destroy a row. RowStatus values of active(1), notReady(3), and createAndWait(5) are ignored.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zhnTrapTypeColdStart 1.3.6.1.4.1.5504.2.5.2.1.8.7
Enable or disable the generation of coldstart traps. A coldstart trap is generated each time the device is restarted.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

zhnTrapTypeWarmStart 1.3.6.1.4.1.5504.2.5.2.1.8.8
Enable or disable the generation of warmstart traps. A warmstart trap is generated each time the device's SNMP agent is restarted.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

zhnTrapTypeEnterprise 1.3.6.1.4.1.5504.2.5.2.1.8.9
Enable or disable the generation of all enterprise traps.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

zhnFixedCommunityTable 1.3.6.1.4.1.5504.2.5.2.1.7.3
This table is used to configure a read-only and a read-write community.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhnFixedCommunityTableEntry

zhnFixedCommunityTableEntry 1.3.6.1.4.1.5504.2.5.2.1.7.3.1
This object corresponds to an entry in the fixed community table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhnFixedCommunityTableEntry  

fixedCommunityName 1.3.6.1.4.1.5504.2.5.2.1.7.3.1.1
This object corresponds to the SNMP community string.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString  

fixedCommunityType 1.3.6.1.4.1.5504.2.5.2.1.7.3.1.2
The access type of the community string. The default value of this object should be read-only(1).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER readOnly(1), readWrite(2)  

fixedCommunityRowStatus 1.3.6.1.4.1.5504.2.5.2.1.7.3.1.3
When written, this object is ignored. When read, a value of active(1) or notReady(3) will be returned.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

sysLogAdminStatus 1.3.6.1.4.1.5504.2.5.2.1.9.1
Enable or disable the Syslog service.
Status: current Access: read-write
OBJECT-TYPE    
  SysAdminStatus  

sysLogLocalLogLevel 1.3.6.1.4.1.5504.2.5.2.1.9.2
SysLog local log level options, per RFC 3164. All logged events with a severity at or greater than this level will be logged to the local log file. Note, the local log file is not persistent across system reboots.
Status: current Access: read-write
OBJECT-TYPE    
  SysLogLevel  

sysLogRemoteLogLevel 1.3.6.1.4.1.5504.2.5.2.1.9.3
SysLog remote log level options, per RFC 3164. All logged events with a severity at or greater that this level will be sent to a remote Syslog server if the remote server address is configured and a route exists to the remote server.
Status: current Access: read-write
OBJECT-TYPE    
  SysLogLevel  

sysLogDisplayLogLevel 1.3.6.1.4.1.5504.2.5.2.1.9.4
SysLog log level options, per RFC 3164 for the display of log messages via a web browser. All logged events with a severity level at or greater than this level will be displayed.
Status: current Access: read-write
OBJECT-TYPE    
  SysLogLevel  

sysLogMode 1.3.6.1.4.1.5504.2.5.2.1.9.5
SysLog logging mode of operation: local(1), -- Log messages only to the local, non-persistent log file remote(2), -- Log messages only to a remote syslog server both(3), -- Log messages to both a local log file and a remote syslog server
Status: current Access: read-write
OBJECT-TYPE    
  SysLogMode  

sysLogRemoteServerAddress 1.3.6.1.4.1.5504.2.5.2.1.9.6
The IP address of the remote syslog server.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

sysLogRemoteServerPort 1.3.6.1.4.1.5504.2.5.2.1.9.7
The UDP port to use to transfer syslog messages to the remote syslog server.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..65535  

sntpAdminStatus 1.3.6.1.4.1.5504.2.5.2.1.10.1
Enable or disable the SNTP client.
Status: current Access: read-write
OBJECT-TYPE    
  SysAdminStatus  

sntpOperStatus 1.3.6.1.4.1.5504.2.5.2.1.10.2
Current operational status of the SNTP client.
Status: current Access: read-write
OBJECT-TYPE    
  SysAdminStatus  

sntpServer1 1.3.6.1.4.1.5504.2.5.2.1.10.3
The domain name or IP address of the first SNTP server with which to synchronize the system time.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

sntpServer2 1.3.6.1.4.1.5504.2.5.2.1.10.4
The domain name or IP address of the second SNTP server with which to synchronize the system time.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

sntpServer3 1.3.6.1.4.1.5504.2.5.2.1.10.5
The domain name or IP address of the third SNTP server with which to synchronize the system time.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

sntpServer4 1.3.6.1.4.1.5504.2.5.2.1.10.6
The domain name or IP address of the fourth SNTP server with which to synchronize the system time.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

sntpServer5 1.3.6.1.4.1.5504.2.5.2.1.10.7
The domain name or IP address of the fifth SNTP server with which to synchronize the system time.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

sntpLocalTimeZone 1.3.6.1.4.1.5504.2.5.2.1.10.8
Indicates the local time zone.
Status: current Access: read-write
OBJECT-TYPE    
  SysSntpTimeZones  

sntpCurrentDateAndTime 1.3.6.1.4.1.5504.2.5.2.1.10.9
Indicates the current date and time.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

adminUserName 1.3.6.1.4.1.5504.2.5.2.1.11.1
The username required to login as the system administrator. This user has unrestricted access to change and view all configuration, status and test parameters.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

adminPassword 1.3.6.1.4.1.5504.2.5.2.1.11.2
The password required to login as the system administrator. This field cannot contain a SPACE and is returned as a string of asterisks.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

supportUserName 1.3.6.1.4.1.5504.2.5.2.1.11.3
The username required to login to support the system. This user has access to system parameters required to maintain the system and run diagnostic tests.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

supportPassword 1.3.6.1.4.1.5504.2.5.2.1.11.4
The password required to login to support the system. This field cannot contain a SPACE and is returned as a string of asterisks.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

userUserName 1.3.6.1.4.1.5504.2.5.2.1.11.5
The username required to login as a general user of the system. This user can view configuration settings and statistics, as well as, update the system's software.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

userPassword 1.3.6.1.4.1.5504.2.5.2.1.11.6
The password required to login as a general user of the system. field cannot contain a SPACE and is returned as a string of asterisks.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

powerSheddingAdminStatus 1.3.6.1.4.1.5504.2.5.2.1.12.1
Configuration of parameters for the power-shedding feature. The power-shedding objects are only supported by systems that include on-board power-management circuitry. When the system detects that it is running on battery power, it has the option to shut down all support (excluding the voice over IP telephone service).The power-shedding administrative state will enable or disable the power-shedding feature.
Status: current Access: read-only
OBJECT-TYPE    
  SysAdminStatus  

powerSheddingShutdownDelay 1.3.6.1.4.1.5504.2.5.2.1.12.2
The shutdown delay is the time delay, in minutes, after AC power is lost, before shutting down non-voice services.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..60  

powerSheddingRestoreDelay 1.3.6.1.4.1.5504.2.5.2.1.12.3
The restore delay is the time delay, in minutes, after AC power is restored before switching on the services that were shut down due to the power loss.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..10  

sysFirewallEnable 1.3.6.1.4.1.5504.2.5.2.1.13.1
Enables or disables the firewall feature for the entire system.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

sysFirewallTcpSynCookies 1.3.6.1.4.1.5504.2.5.2.1.13.2
Enables or disables the TCP SYNCookie protection against SYN flooding denial-of-service attack.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sysDNSAddressingType 1.3.6.1.4.1.5504.2.5.2.1.14.1
Type of IP interface addressing method used to reach the DNS.
Status: current Access: read-write
OBJECT-TYPE    
  IPInterfaceAddressingTypeValues  

sysDNSDHCPSource 1.3.6.1.4.1.5504.2.5.2.1.14.2
Name of the interface used by the DHCP Client to obtain DNS information.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

sysDNSPrimaryIPAddress 1.3.6.1.4.1.5504.2.5.2.1.14.3
Primary Address of DNS when the addressing type is set to Static.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

sysDNSSecondaryIPAddress 1.3.6.1.4.1.5504.2.5.2.1.14.4
Secondary Address of DNS when the addressing type is set to Static.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

zhnDnsProxyHostMaxHostEntries 1.3.6.1.4.1.5504.2.5.2.1.15.1
The maximum number of host entries in the DnsProxyHostObjectTable.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..24  

zhnDnsProxyHostTable 1.3.6.1.4.1.5504.2.5.2.1.15.2
This table is used to configure a DNS Proxy Host entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhnDnsProxyHostEntry

zhnDnsProxyHostEntry 1.3.6.1.4.1.5504.2.5.2.1.15.2.1
This object corresponds to an entry in the DNS Proxy Host table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhnDnsProxyHostEntry  

dnsProxyHostIndex 1.3.6.1.4.1.5504.2.5.2.1.15.2.1.1
Index into the DNS Proxy Host table
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..24  

dnsProxyHostIPAddress 1.3.6.1.4.1.5504.2.5.2.1.15.2.1.2
The local proxy host IP address.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

dnsProxyHostName 1.3.6.1.4.1.5504.2.5.2.1.15.2.1.3
The domain name assigned to the host IP address.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

dnsProxyRowStatus 1.3.6.1.4.1.5504.2.5.2.1.15.2.1.4
Create or destroy a DNS Proxy Host. Upon creation, the dnsProxyHostIPAddress must be provided.
Status: current Access: read-create
OBJECT-TYPE    
  ZhoneRowStatus  

failoverTimer 1.3.6.1.4.1.5504.2.5.2.1.16.1
The WAN Failover Timer is used to determine how long (in seconds) the Fiber uplink interface must be operationally DOWN before a USB Cellular WAN Backup connection will be initiated. The Default value is 0 seconds, which DISABLES this feature. The recommended value to enable this feature is 60 seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

restoralTimer 1.3.6.1.4.1.5504.2.5.2.1.16.2
The WAN Restoral Timer is used to determine how long (in seconds) the Fiber uplink interface must remain in an operational UP condition before the Cellular Backup connection will be terminated and the traffic that was being forwarded out the USB interface is forwarded to the 5xx GEM instead. The default value is 60 seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

backupDataVlan 1.3.6.1.4.1.5504.2.5.2.1.16.3
This is the Internet Access VLAN (GEM 5xx), which is the only service that can be backed up using the USB Cellular modem.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..4096  

cellularPinNumber 1.3.6.1.4.1.5504.2.5.2.1.16.4
A 4 digit PIN code used to unlock the SIM card. For GPRS/UMTS networks, *99# is typically used. For CDMA/EVDO networks, #777 is typically used.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

cellularDataNumber 1.3.6.1.4.1.5504.2.5.2.1.16.5
This is the number that the USB modem will dial to establish a cellular a cellular data connection. For GPRS/UMTS networks, *99# is typically used. For CDMA/EVDO networks, #777 is typically used.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

atInitCommands 1.3.6.1.4.1.5504.2.5.2.1.16.6
AT initialization command strings, if needed.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

accessPointName 1.3.6.1.4.1.5504.2.5.2.1.16.7
The Access Point Name (APN) for connections to the GPRS/UMTS network. This should be provided by the ISP. In North America, 3G cellular carriers do not require an APN.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

chapPapUsername 1.3.6.1.4.1.5504.2.5.2.1.16.8
Required for CHAP or PAP authentication. This configuration item should be left blank if CHAP or PAP is not used.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

chapPapPassword 1.3.6.1.4.1.5504.2.5.2.1.16.9
Required for CHAP or PAP authentication. This configuration item should be left blank if CHAP or PAP is not used.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

connectionTimeout 1.3.6.1.4.1.5504.2.5.2.1.16.10
Specifies the duration of inactivity in seconds before the cellular data call will automatically terminate. A new call will be initiated automatically when a packet must be sent upstream on the designated VLAN if the WAN uplink is still Operationally Down. A value of 0 will DISABLE the Connection Timeout feature.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

backupIpAddressMode 1.3.6.1.4.1.5504.2.5.2.1.16.11
The WAN IP Address, Default Gateway IP Address, Subnet Mask and DNS Server IP Address must all be defined for the USB Cellular Backup connection. When IP Address Mode is set to DHCP, a DHCP Request will be sent upstream after the Cellular Data Connection has been established to acquire this information dynamically. When the WAN Backup IP Addess Mode is set to Static, this information ust be statically configured.
Status: current Access: read-write
OBJECT-TYPE    
  BasicAddressingTypeValues  

backupIpAddress 1.3.6.1.4.1.5504.2.5.2.1.16.12
The IP Address to be used on the WAN uplink interface of a Cellular Backhaul connection. This parameter is acquired dynamically in DHCP mode and only configurable if the BackupIpAddressMode is Static.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

backupDefaultGateway 1.3.6.1.4.1.5504.2.5.2.1.16.13
The IP Address of the Default Gateway to be used on the WAN uplink interface of a Cellular Backhaul connection. This parameter is acquired dynamically in DHCP mode and only configurable if the BackupIpAddressMode is Static.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

backupSubnetMask 1.3.6.1.4.1.5504.2.5.2.1.16.14
The Subnet Mask to be used on the WAN uplink interface of a Cellular Backhaul connection. This parameter is acquired dynamically in DHCP mode and only configurable if the BackupIpAddressMode is Static.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

backupPrimaryDns 1.3.6.1.4.1.5504.2.5.2.1.16.15
The IP Address of the Primary DNS Server to be used on the WAN uplink interface of a Cellular Backhaul connection. This parameter is acquired dynamically in DHCP mode and only configurable if the BackupIpAddressMode is Static.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

backupSecondaryDns 1.3.6.1.4.1.5504.2.5.2.1.16.16
The IP Address of the Secondary DNS Server to be used on the WAN uplink interface of a Cellular Backhaul connection. This parameter is acquired dynamically in DHCP mode and only configurable if the BackupIpAddressMode is Static.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

sysTr69cConfigObjects 1.3.6.1.4.1.5504.2.5.2.1.17.1
OBJECT IDENTIFIER    

sysTr69cServerObjects 1.3.6.1.4.1.5504.2.5.2.1.17.2
OBJECT IDENTIFIER    

sysTr69cConfigLoggingSOAP 1.3.6.1.4.1.5504.2.5.2.1.17.1.1
Enable or disable showing SOAP messages on serial console and local TR69 Client log file.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

sysTr69cConfigConnectionRequestAuthentication 1.3.6.1.4.1.5504.2.5.2.1.17.1.2
Enable or disable connection request authentication.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

sysTr69cServerURL 1.3.6.1.4.1.5504.2.5.2.1.17.2.1
URL for the CPE to connect to the ACS using the CPE WAN Management Protocol. This parameter MUST be in the form of a valid HTTP or HTTPS URL. The host portion of this URL is used by the CPE for server-side certificate authentication when using SSL or TLS.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

sysTr69cServerLastConnectedURL 1.3.6.1.4.1.5504.2.5.2.1.17.2.2
This value records the last URL which connected successfully to the TR69 client.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

sysTr69cServerUsername 1.3.6.1.4.1.5504.2.5.2.1.17.2.3
Username used to authenticate the CPE when making a connection to the ACS using the CPE WAN Management Protocol. This username is used only for HTTP-based authentication of the CPE.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

sysTr69cServerPassword 1.3.6.1.4.1.5504.2.5.2.1.17.2.4
Password used to authenticate the CPE when making a connection to the ACS using the CPE WAN Management Protocol. This username is used only for HTTP-based authentication of the CPE. When read by an ACS, this parameter returns an empty string, regardless of the value.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

sysTr69cServerPeriodicInformEnable 1.3.6.1.4.1.5504.2.5.2.1.17.2.5
When set to TRUE, the CPE will periodically send CPE information to the TR69 Server using the Inform method calls.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

sysTr69cServerPeriodicInformInterval 1.3.6.1.4.1.5504.2.5.2.1.17.2.6
The duration in seconds of the interval for which the CPE MUST attempt to connect with the ACS and call the Inform method if PeriodicInform-Enable is true.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

sysTr69cServerParameterKey 1.3.6.1.4.1.5504.2.5.2.1.17.2.7
ParameterKey provides the ACS a reliable and extensible means to track changes made by the ACS. The value of ParameterKey MUST be equal to the value of the ParameterKey argument from the most recent successful SetParameterValues, AddObject, or DeleteObject method call from the ACS. The CPE MUST set ParameterKey to the value specified in the corresponding method arguments if and only if the method completes successfully and no fault response is generated. If a method call does not complete successfully implying that the changes requested in the method did not take effect, the value of ParameterKey MUST NOT be modified. The CPE MUST only modify the value of ParameterKey as a result of SetParameterValues, AddObject, DeleteObject, or due to a factory reset. On factory reset, the value of ParameterKey MUST be set to empty.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

sysTr69cServerBoundIfName 1.3.6.1.4.1.5504.2.5.2.1.17.2.8
Name of the WAN interface that the TR69 client should use when establishing communications with the ACS.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

sysTr69cServerConnectionRequestURL 1.3.6.1.4.1.5504.2.5.2.1.17.2.9
HTTP URL for an ACS to make a Connection Request notification to the CPE. In the form: http://host:port/path. The host portion of the URL MAY be the IP address for the management interface of the CPE in lieu of a host name.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

sysTr69cServerConnectionRequestUsername 1.3.6.1.4.1.5504.2.5.2.1.17.2.10
Username used to authenticate an ACS making a Connection Request to the CPE.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

sysTr69cServerConnectionRequestPassword 1.3.6.1.4.1.5504.2.5.2.1.17.2.11
Password used to authenticate an ACS making a Connection Request to the CPE. When read by an ACS, this parameter returns an empty string, regardless of the actual value.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..256)  

sysTr69cServerUpgradesManaged 1.3.6.1.4.1.5504.2.5.2.1.17.2.12
Indicates whether or not the ACS will manage upgrades for the CPE. If true (1), the CPE SHOULD not use other means other than the ACS to seek out available upgrades. If false (0), the CPE MAY use other means for this purpose.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

zhnSystemConformance 1.3.6.1.4.1.5504.2.5.2.2
OBJECT IDENTIFIER    

zhnSystemGroups 1.3.6.1.4.1.5504.2.5.2.2.1
OBJECT IDENTIFIER    

zhnSystemCompliances 1.3.6.1.4.1.5504.2.5.2.2.2
OBJECT IDENTIFIER    

zhnSystemCompliance 1.3.6.1.4.1.5504.2.5.2.2.2.1
The Compliance statement for SNMP entities which manage the display of Zhone System Information
Status: current Access: read-only
MODULE-COMPLIANCE    

zhnSystemActiveGroup 1.3.6.1.4.1.5504.2.5.2.2.1.1
A collection of System Information objects that are required for the device to be functional
Status: current Access: read-only
OBJECT-GROUP    

zhnSystemTablesItems 1.3.6.1.4.1.5504.2.5.2.2.1.2
The table items for the device that are filled in when the table is present
Status: current Access: read-only
OBJECT-GROUP    

zhnSystemConfigItems 1.3.6.1.4.1.5504.2.5.2.2.1.3
The collection of configurable scalar system objects.
Status: current Access: read-only
OBJECT-GROUP    

zhnSystemTrapItems 1.3.6.1.4.1.5504.2.5.2.2.1.4
The collection of SNMP trap objects.
Status: current Access: read-only
OBJECT-GROUP    

zhnSystemCommunityItems 1.3.6.1.4.1.5504.2.5.2.2.1.5
The collection of SNMP community objects.
Status: current Access: read-only
OBJECT-GROUP    

zhnSystemFixedCommunityItems 1.3.6.1.4.1.5504.2.5.2.2.1.6
The collection of pre-provisioned SNMP community objects.
Status: current Access: read-only
OBJECT-GROUP    

zhnSystemClockingItems 1.3.6.1.4.1.5504.2.5.2.2.1.7
The collection of system-wide clocking parameters only supported by ZNID devices.
Status: current Access: read-only
OBJECT-GROUP    

zhnSyslogConfigGroup 1.3.6.1.4.1.5504.2.5.2.2.1.8
The collection of system-wide logging parameters only supported by ZNID devices.
Status: current Access: read-only
OBJECT-GROUP    

zhnSntpConfigGroup 1.3.6.1.4.1.5504.2.5.2.2.1.9
The collection of SNTP server parameters only supported by ZNID devices.
Status: current Access: read-only
OBJECT-GROUP    

zhnUserLoginGroup 1.3.6.1.4.1.5504.2.5.2.2.1.10
The collection of User login parameters only supported by ZNID devices.
Status: current Access: read-only
OBJECT-GROUP    

zhnPowerSheddingGroup 1.3.6.1.4.1.5504.2.5.2.2.1.11
The collection of configurable power-shedding parameters only supported by ZNID devices.
Status: current Access: read-only
OBJECT-GROUP    

zhnSystemFirewallGroup 1.3.6.1.4.1.5504.2.5.2.2.1.12
The collection of system firewall parameters only supported by ZNID devices.
Status: current Access: read-only
OBJECT-GROUP    

zhnSystemDNSClientGroup 1.3.6.1.4.1.5504.2.5.2.2.1.13
The collection of system DNS Client parameters only supported by ZNID devices.
Status: current Access: read-only
OBJECT-GROUP    

zhnSystemDNSProxyHostGroup 1.3.6.1.4.1.5504.2.5.2.2.1.14
The collection of system DNS Proxy Host parameters only supported by ZNID devices.
Status: current Access: read-only
OBJECT-GROUP    

zhnSystemWanBackupGroup 1.3.6.1.4.1.5504.2.5.2.2.1.15
The collection of system WAN Backup parameters only supported by ZNID devices.
Status: current Access: read-only
OBJECT-GROUP    

zhnSystemTr69cGroup 1.3.6.1.4.1.5504.2.5.2.2.1.16
The collection of system TR69 Client parameters only supported by ZNID devices.
Status: current Access: read-only
OBJECT-GROUP