XYLAN-OAM-MIB

File: XYLAN-OAM-MIB.mib (29688 bytes)

Imported modules

RFC-1212 RFC-1215 XYLAN-BASE-MIB

Imported symbols

OBJECT-TYPE TRAP-TYPE xylanOamArch

Defined Types

XylanOamF4VPEntry  
SEQUENCE    
  xylanOamF4VPSlotIndex INTEGER
  xylanOamF4VPPortIndex INTEGER
  xylanOamF4VPVpiIndex INTEGER
  xylanOamF4VPAdminEnable INTEGER
  xylanOamF4VPAisEnable INTEGER
  xylanOamF4VPRdiEnable INTEGER
  xylanOamF4VPContCheckEnable INTEGER
  xylanOamF4VPTrapOnAlarmEnable INTEGER
  xylanOamF4VPLoopbackEnable INTEGER
  xylanOamF4VPLoopbackType INTEGER
  xylanOamF4VPLoopbackStatus INTEGER
  xylanOamF4VPContCheckStatus INTEGER
  xylanOamF4VPAisRxCount INTEGER
  xylanOamF4VPAisTxCount INTEGER
  xylanOamF4VPRdiRxCount INTEGER
  xylanOamF4VPRdiTxCount INTEGER
  xylanOamF4VPLoopbackRxCount INTEGER
  xylanOamF4VPLoopbackTxCount INTEGER
  xylanOamF4VPContCheckRxCount INTEGER
  xylanOamF4VPContCheckTxCount INTEGER
  xylanOamF4VPLOCCount INTEGER
  xylanOamF4VPLoopbackSuccessCount INTEGER
  xylanOamF4VPLoopbackFailureCount INTEGER
  xylanOamF4VPSegmentAction INTEGER
  xylanOamF4VPEndtoendAction INTEGER

XylanOamF5VCEntry  
SEQUENCE    
  xylanOamF5VCSlotIndex INTEGER
  xylanOamF5VCPortIndex INTEGER
  xylanOamF5VCVpiIndex INTEGER
  xylanOamF5VCVciIndex INTEGER
  xylanOamF5VCAdminEnable INTEGER
  xylanOamF5VCAisEnable INTEGER
  xylanOamF5VCRdiEnable INTEGER
  xylanOamF5VCContCheckEnable INTEGER
  xylanOamF5VCTrapOnAlarmEnable INTEGER
  xylanOamF5VCLoopbackEnable INTEGER
  xylanOamF5VCLoopbackType INTEGER
  xylanOamF5VCLoopbackStatus INTEGER
  xylanOamF5VCContCheckStatus INTEGER
  xylanOamF5VCAisRxCount INTEGER
  xylanOamF5VCAisTxCount INTEGER
  xylanOamF5VCRdiRxCount INTEGER
  xylanOamF5VCRdiTxCount INTEGER
  xylanOamF5VCLoopbackRxCount INTEGER
  xylanOamF5VCLoopbackTxCount INTEGER
  xylanOamF5VCContCheckRxCount INTEGER
  xylanOamF5VCContCheckTxCount INTEGER
  xylanOamF5VCLOCCount INTEGER
  xylanOamF5VCLoopbackSuccessCount INTEGER
  xylanOamF5VCLoopbackFailureCount INTEGER
  xylanOamF5VCSegmentAction INTEGER
  xylanOamF5VCEndtoendAction INTEGER

Defined Values

xylanOam 1.3.6.1.4.1.800.2.28.1
OBJECT IDENTIFIER    

xylanOamF4VPTable 1.3.6.1.4.1.800.2.28.1.1
OAM F4 VP configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    XylanOamF4VPEntry

xylanOamF4VPEntry 1.3.6.1.4.1.800.2.28.1.1.1
An entry in the OAM F4 VP configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  XylanOamF4VPEntry  

xylanOamF4VPSlotIndex 1.3.6.1.4.1.800.2.28.1.1.1.1
A unique value which identifies CSM board slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..9  

xylanOamF4VPPortIndex 1.3.6.1.4.1.800.2.28.1.1.1.2
A unique value which identifies CSM module port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

xylanOamF4VPVpiIndex 1.3.6.1.4.1.800.2.28.1.1.1.3
A unique value which identifies this VP connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF4VPAdminEnable 1.3.6.1.4.1.800.2.28.1.1.1.4
A value to indicate whether this VP connection is enabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

xylanOamF4VPAisEnable 1.3.6.1.4.1.800.2.28.1.1.1.5
A value to indicate whether AIS transmission is enabled or disabled for this VP connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

xylanOamF4VPRdiEnable 1.3.6.1.4.1.800.2.28.1.1.1.6
A value to indicate whether RDI transmission is enabled or disabled for this VP connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

xylanOamF4VPContCheckEnable 1.3.6.1.4.1.800.2.28.1.1.1.7
A value to indicate whether VP Continuity Check is enabled or disabled for this VP connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

xylanOamF4VPTrapOnAlarmEnable 1.3.6.1.4.1.800.2.28.1.1.1.8
A value to indicate whether ATM Layer Trap generation on alarms is enabled or disabled for this VP connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

xylanOamF4VPLoopbackEnable 1.3.6.1.4.1.800.2.28.1.1.1.9
A value to indicate whether Loopback is enabled or disabled for this VP connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

xylanOamF4VPLoopbackType 1.3.6.1.4.1.800.2.28.1.1.1.10
A unique value indicates Loopback Type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER end-to-end(1), access-line(2), inter-domain(3), network-to-endpoint(4), intra-domain(5)  

xylanOamF4VPLoopbackStatus 1.3.6.1.4.1.800.2.28.1.1.1.11
A unique value indicates Loopback Status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), successful(2), unsuccessful(3), responsewaiting(4)  

xylanOamF4VPContCheckStatus 1.3.6.1.4.1.800.2.28.1.1.1.12
A unique value indicates VP Continuity Check Status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ready(1), waitingActivate(2), waitingDeactivate(3), active(4), disabled(5)  

xylanOamF4VPAisRxCount 1.3.6.1.4.1.800.2.28.1.1.1.13
A unique value indicates number of received AIS cells on this VP connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF4VPAisTxCount 1.3.6.1.4.1.800.2.28.1.1.1.14
A unique value indicates number of transmitted AIS cells on this VP connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF4VPRdiRxCount 1.3.6.1.4.1.800.2.28.1.1.1.15
A unique value indicates number of received RDI cells on this VP connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF4VPRdiTxCount 1.3.6.1.4.1.800.2.28.1.1.1.16
A unique value indicates number of transmitted RDI cells on this VP connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF4VPLoopbackRxCount 1.3.6.1.4.1.800.2.28.1.1.1.17
A unique value indicates number of received Loopback cells on this VP connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF4VPLoopbackTxCount 1.3.6.1.4.1.800.2.28.1.1.1.18
A unique value indicates number of transmitted Loopback cells on this VP connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF4VPContCheckRxCount 1.3.6.1.4.1.800.2.28.1.1.1.19
A unique value indicates number of received Continuity Check cells on this VP connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF4VPContCheckTxCount 1.3.6.1.4.1.800.2.28.1.1.1.20
A unique value indicates number of received Continuity Check cells on this VP connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF4VPLOCCount 1.3.6.1.4.1.800.2.28.1.1.1.21
A unique value indicates number of Loss of Continuity on this VP connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF4VPLoopbackSuccessCount 1.3.6.1.4.1.800.2.28.1.1.1.22
A unique value indicates number of successful Loopbacks on this VP connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF4VPLoopbackFailureCount 1.3.6.1.4.1.800.2.28.1.1.1.23
A unique value indicates number of unsuccessful Loopbacks on this VP connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF4VPSegmentAction 1.3.6.1.4.1.800.2.28.1.1.1.24
A unique value indicates the configuration on this VP connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), copy(2), extract(3)  

xylanOamF4VPEndtoendAction 1.3.6.1.4.1.800.2.28.1.1.1.25
A unique value indicates the configuration on this VP connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), copy(2), extract(3)  

xylanOamF5VCTable 1.3.6.1.4.1.800.2.28.1.2
OAM F4 VC connection configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    XylanOamF5VCEntry

xylanOamTraps 1.3.6.1.4.1.800.2.28.1.3
OBJECT IDENTIFIER    

xylanOamF5VCEntry 1.3.6.1.4.1.800.2.28.1.2.1
An entry in the OAM F5 VC connection configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  XylanOamF5VCEntry  

xylanOamF5VCSlotIndex 1.3.6.1.4.1.800.2.28.1.2.1.1
A unique value which identifies CSM board slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..9  

xylanOamF5VCPortIndex 1.3.6.1.4.1.800.2.28.1.2.1.2
A unique value which identifies CSM module port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

xylanOamF5VCVpiIndex 1.3.6.1.4.1.800.2.28.1.2.1.3
A unique value which identifies this VC connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF5VCVciIndex 1.3.6.1.4.1.800.2.28.1.2.1.4
A unique value which identifies this VC connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF5VCAdminEnable 1.3.6.1.4.1.800.2.28.1.2.1.5
A value to indicate whether this VC connection is enabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

xylanOamF5VCAisEnable 1.3.6.1.4.1.800.2.28.1.2.1.6
A value to indicate whether AIS tranmission is enabled or disabled for this VC connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

xylanOamF5VCRdiEnable 1.3.6.1.4.1.800.2.28.1.2.1.7
A value to indicate whether RDI transmission is enabled or disabled for this VC connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

xylanOamF5VCContCheckEnable 1.3.6.1.4.1.800.2.28.1.2.1.8
A value to indicate whether VCC Continuity Check is enabled or disabled for this VC connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

xylanOamF5VCTrapOnAlarmEnable 1.3.6.1.4.1.800.2.28.1.2.1.9
A value to indicate whether ATM Layer trap generation on alarms is enabled or disabled for this VC connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

xylanOamF5VCLoopbackEnable 1.3.6.1.4.1.800.2.28.1.2.1.10
A value to indicate whether Loopback is enabled or disabled for this VC connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

xylanOamF5VCLoopbackType 1.3.6.1.4.1.800.2.28.1.2.1.11
A unique value indicates Loopback Type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER end-to-end(1), access-line(2), inter-domain(3), network-to-endpoint(4), intra-domain(5)  

xylanOamF5VCLoopbackStatus 1.3.6.1.4.1.800.2.28.1.2.1.12
A unique value indicates Loopback Status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), successful(2), unsuccessful(3), responsewaiting(4)  

xylanOamF5VCContCheckStatus 1.3.6.1.4.1.800.2.28.1.2.1.13
A unique value indicates VCC Continuity Check Status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ready(1), waitingActivate(2), waitingDeactivate(3), active(4), disabled(5)  

xylanOamF5VCAisRxCount 1.3.6.1.4.1.800.2.28.1.2.1.14
A unique value indicates number of received AIS cells on this VC connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF5VCAisTxCount 1.3.6.1.4.1.800.2.28.1.2.1.15
A unique value indicates number of transmitted AIS cells on this VC connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF5VCRdiRxCount 1.3.6.1.4.1.800.2.28.1.2.1.16
A unique value indicates number of received RDI cells on this VC connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF5VCRdiTxCount 1.3.6.1.4.1.800.2.28.1.2.1.17
A unique value indicates number of transmitted RDI cells on this VC connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF5VCLoopbackRxCount 1.3.6.1.4.1.800.2.28.1.2.1.18
A unique value indicates number of received Loopback cells on this VC connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF5VCLoopbackTxCount 1.3.6.1.4.1.800.2.28.1.2.1.19
A unique value indicates number of transmitted Loopback cells on this VC connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF5VCContCheckRxCount 1.3.6.1.4.1.800.2.28.1.2.1.20
A unique value indicates number of received VCC Continuity Check cells on this VC connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF5VCContCheckTxCount 1.3.6.1.4.1.800.2.28.1.2.1.21
A unique value indicates number of transmitted VCC Continuity Check cells on this VC connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF5VCLOCCount 1.3.6.1.4.1.800.2.28.1.2.1.22
A unique value indicates number of Loss of Continuity on this VC connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF5VCLoopbackSuccessCount 1.3.6.1.4.1.800.2.28.1.2.1.23
A unique value indicates number of successful loopbacks on this VC connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF5VCLoopbackFailureCount 1.3.6.1.4.1.800.2.28.1.2.1.24
A unique value indicates number of unsuccessful loopbacks on this VC connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

xylanOamF5VCSegmentAction 1.3.6.1.4.1.800.2.28.1.2.1.25
A unique value indicates the F5 segment configuration on this VC connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), copy(2), extract(3)  

xylanOamF5VCEndtoendAction 1.3.6.1.4.1.800.2.28.1.2.1.26
A unique value indicates the F5 Endpoint configuration on this VC connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), copy(2), extract(3)  

xylanOamTrapVCAIS 1
This trap signifies that the specified connection is in VC-AIS state.
TRAP-TYPE    

xylanOamTrapVCRDI 2
This trap signifies that the specified connection is in VC-RDI state.
TRAP-TYPE    

xylanOamTrapVCLOC 3
This trap signifies that the specified connection is in VC-LOC state.
TRAP-TYPE    

xylanOamTrapVCUnsuccessLoop 4
This trap signifies that the specified connection is unsuccessful Loopback state.
TRAP-TYPE    

xylanOamTrapVPAIS 5
This trap signifies that the specified VP connection is in VP-AIS state.
TRAP-TYPE    

xylanOamTrapVPRDI 6
This trap signifies that the specified VP connection is in VP-RDI state.
TRAP-TYPE    

xylanOamTrapVPLOC 7
This trap signifies that the specified VP connection is in VP-LOC state.
TRAP-TYPE    

xylanOamTrapVPUnsuccessLoop 8
This trap signifies that the specified VP connection is in Unsuccessful loopback state.
TRAP-TYPE