Wellfleet-X25PAD-MIB

File: Wellfleet-X25PAD-MIB.mib (52382 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
Wellfleet-COMMON-MIB

Imported symbols

Counter OBJECT-TYPE DisplayString
wfX25PadGroup

Defined Types

WfX25PadDefaultCfgEntry  
SEQUENCE    
  wfX25PadDefaultCfgDelete INTEGER
  wfX25PadDefaultCfgDisable INTEGER
  wfX25PadDefaultCfgState INTEGER
  wfX25PadDefaultCfgSlot INTEGER
  wfX25PadDefaultCfgConnector INTEGER
  wfX25PadDefaultCfgCircuit INTEGER
  wfX25PadDefaultCfgX121Addr DisplayString
  wfX25PadDefaultCfgDNIC DisplayString
  wfX25PadDefaultCfgLenSubAddress INTEGER
  wfX25PadDefaultCfgLCNLow INTEGER
  wfX25PadDefaultCfgLCNHigh INTEGER

WfX25PadCurrentCfgEntry  
SEQUENCE    
  wfX25PadCurrentCfgState INTEGER
  wfX25PadCurrentCfgSlot INTEGER
  wfX25PadCurrentCfgConnector INTEGER
  wfX25PadCurrentCfgCircuit INTEGER
  wfX25PadCurrentCfgX121Addr DisplayString
  wfX25PadCurrentCfgDNIC DisplayString
  wfX25PadCurrentCfgLenSubAddress INTEGER
  wfX25PadCurrentCfgLCNLow INTEGER
  wfX25PadCurrentCfgLCNHigh INTEGER

WfX25PadStatEntry  
SEQUENCE    
  wfX25PadStatState INTEGER
  wfX25PadStatSlot INTEGER
  wfX25PadStatConnector INTEGER
  wfX25PadStatTotalConnCount Counter
  wfX25PadStatRxRR Counter
  wfX25PadStatTxRR Counter
  wfX25PadStatRxRNR Counter
  wfX25PadStatTxRNR Counter
  wfX25PadStatRxRestart Counter
  wfX25PadStatTxRestart Counter

WfX25PadPortDefaultCfgEntry  
SEQUENCE    
  wfX25PadPortDefaultCfgDelete INTEGER
  wfX25PadPortDefaultCfgDisable INTEGER
  wfX25PadPortDefaultCfgState INTEGER
  wfX25PadPortDefaultCfgSlot INTEGER
  wfX25PadPortDefaultCfgConnector INTEGER
  wfX25PadPortDefaultCfgNumber INTEGER
  wfX25PadPortDefaultCfgSubAddress DisplayString
  wfX25PadPortDefaultCfgLenSubAddress INTEGER
  wfX25PadPortDefaultCfgX3escape INTEGER
  wfX25PadPortDefaultCfgX3echo INTEGER
  wfX25PadPortDefaultCfgX3forward INTEGER
  wfX25PadPortDefaultCfgX3idle INTEGER
  wfX25PadPortDefaultCfgX3device INTEGER
  wfX25PadPortDefaultCfgX3signals INTEGER
  wfX25PadPortDefaultCfgX3break INTEGER
  wfX25PadPortDefaultCfgX3discard INTEGER
  wfX25PadPortDefaultCfgX3CRpad INTEGER
  wfX25PadPortDefaultCfgX3folding INTEGER
  wfX25PadPortDefaultCfgX3speed INTEGER
  wfX25PadPortDefaultCfgX3flow INTEGER
  wfX25PadPortDefaultCfgX3LFinsert INTEGER
  wfX25PadPortDefaultCfgX3LFpad INTEGER
  wfX25PadPortDefaultCfgX3Edit INTEGER
  wfX25PadPortDefaultCfgX3Cdelete INTEGER
  wfX25PadPortDefaultCfgX3Ldelete INTEGER
  wfX25PadPortDefaultCfgX3Ldisplay INTEGER
  wfX25PadPortDefaultCfgX3Esignals INTEGER
  wfX25PadPortDefaultCfgX3Mask INTEGER
  wfX25PadPortDefaultCfgX3parity INTEGER
  wfX25PadPortDefaultCfgX3page INTEGER
  wfX25PadPortDefaultCfgLenUserData INTEGER
  wfX25PadPortDefaultCfgUserData OCTET STRING
  wfX25PadPortDefaultCfgLenRawFacilities INTEGER
  wfX25PadPortDefaultCfgRawFacilitiesData OCTET STRING
  wfX25PadPortDefaultCfgReverseCharge OCTET STRING
  wfX25PadPortDefaultCfgThruClassNegotiation OCTET STRING
  wfX25PadPortDefaultCfgPacketSizeNegotiation OCTET STRING
  wfX25PadPortDefaultCfgWindowSizeNegotiation OCTET STRING
  wfX25PadPortDefaultCfgIntervalTimer INTEGER
  wfX25PadPortDefaultCfgFullAddressing INTEGER

WfX25PadPortCurrentCfgEntry  
SEQUENCE    
  wfX25PadPortCurrentCfgState INTEGER
  wfX25PadPortCurrentCfgSlot INTEGER
  wfX25PadPortCurrentCfgConnector INTEGER
  wfX25PadPortCurrentCfgNumber INTEGER
  wfX25PadPortCurrentCfgSubAddress DisplayString
  wfX25PadPortCurrentCfgLenSubAddress INTEGER
  wfX25PadPortCurrentCfgX3escape INTEGER
  wfX25PadPortCurrentCfgX3echo INTEGER
  wfX25PadPortCurrentCfgX3forward INTEGER
  wfX25PadPortCurrentCfgX3idle INTEGER
  wfX25PadPortCurrentCfgX3device INTEGER
  wfX25PadPortCurrentCfgX3signals INTEGER
  wfX25PadPortCurrentCfgX3break INTEGER
  wfX25PadPortCurrentCfgX3discard INTEGER
  wfX25PadPortCurrentCfgX3CRpad INTEGER
  wfX25PadPortCurrentCfgX3folding INTEGER
  wfX25PadPortCurrentCfgX3speed INTEGER
  wfX25PadPortCurrentCfgX3flow INTEGER
  wfX25PadPortCurrentCfgX3LFinsert INTEGER
  wfX25PadPortCurrentCfgX3LFpad INTEGER
  wfX25PadPortCurrentCfgX3Edit INTEGER
  wfX25PadPortCurrentCfgX3Cdelete INTEGER
  wfX25PadPortCurrentCfgX3Ldelete INTEGER
  wfX25PadPortCurrentCfgX3Ldisplay INTEGER
  wfX25PadPortCurrentCfgX3Esignals INTEGER
  wfX25PadPortCurrentCfgX3Mask INTEGER
  wfX25PadPortCurrentCfgX3parity INTEGER
  wfX25PadPortCurrentCfgX3page INTEGER
  wfX25PadPortCurrentCfgLenUserData INTEGER
  wfX25PadPortCurrentCfgUserData OCTET STRING
  wfX25PadPortCurrentCfgLenRawFacilities INTEGER
  wfX25PadPortCurrentCfgRawFacilitiesData OCTET STRING
  wfX25PadPortCurrentCfgReverseCharge OCTET STRING
  wfX25PadPortCurrentCfgThruClassNegotiation OCTET STRING
  wfX25PadPortCurrentCfgPacketSizeNegotiation OCTET STRING
  wfX25PadPortCurrentCfgWindowSizeNegotiation OCTET STRING
  wfX25PadPortCurrentCfgIntervalTimer INTEGER
  wfX25PadPortCurrentCfgFullAddressing INTEGER

WfX25PadPortStatEntry  
SEQUENCE    
  wfX25PadPortStatState INTEGER
  wfX25PadPortStatSlot INTEGER
  wfX25PadPortStatConnector INTEGER
  wfX25PadPortStatNumber INTEGER
  wfX25PadPortStatRxOctets Counter
  wfX25PadPortStatTxOctets Counter
  wfX25PadPortStatRxPackets Counter
  wfX25PadPortStatTxPackets Counter
  wfX25PadPortStatRemoteX121Addr DisplayString
  wfX25PadPortStatLCN INTEGER
  wfX25PadPortStatDuration INTEGER
  wfX25PadPortStatRxRR Counter
  wfX25PadPortStatTxRR Counter
  wfX25PadPortStatRxRNR Counter
  wfX25PadPortStatTxRNR Counter
  wfX25PadPortStatRxClr Counter
  wfX25PadPortStatTxClr Counter
  wfX25PadPortStatRxReset Counter
  wfX25PadPortStatTxReset Counter
  wfX25PadPortStatRxCall Counter
  wfX25PadPortStatTxCall Counter
  wfX25PadPortStatConnections Counter
  wfX25PadPortStatDisconnects Counter
  wfX25PadPortStatLastCause INTEGER
  wfX25PadPortStatLastDiag INTEGER

Defined Values

wfX25PadDefaultCfgTable 1.3.6.1.4.1.18.3.5.9.12.1
Table of X25 PAD Config Objects
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfX25PadDefaultCfgEntry

wfX25PadDefaultCfgEntry 1.3.6.1.4.1.18.3.5.9.12.1.1
An entry in the X25 Pad Config Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfX25PadDefaultCfgEntry  

wfX25PadDefaultCfgDelete 1.3.6.1.4.1.18.3.5.9.12.1.1.1
Create/Delete parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfX25PadDefaultCfgDisable 1.3.6.1.4.1.18.3.5.9.12.1.1.2
Enable/Disable parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfX25PadDefaultCfgState 1.3.6.1.4.1.18.3.5.9.12.1.1.3
Current state of X.25 PAD sofware on the I-SDB
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), init(3)  

wfX25PadDefaultCfgSlot 1.3.6.1.4.1.18.3.5.9.12.1.1.4
Instance ID Slot, filled in by ISDB mib gate
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfX25PadDefaultCfgConnector 1.3.6.1.4.1.18.3.5.9.12.1.1.5
Instance ID Connector, filled in by ISDB mib gate. For the ASN this attribute is an encoded value and is equal to 'module'*10 + 'connector'. Where 'module' is defined in attribute 86 and 'connector' is defined in attribute 78 of this table. For non-ASN platforms this attribute is the physical connector number on the slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfX25PadDefaultCfgCircuit 1.3.6.1.4.1.18.3.5.9.12.1.1.6
Circuit number, filled in by ISDB mib gate
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfX25PadDefaultCfgX121Addr 1.3.6.1.4.1.18.3.5.9.12.1.1.7
X.121 address of the X.25 Pad
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..15)  

wfX25PadDefaultCfgDNIC 1.3.6.1.4.1.18.3.5.9.12.1.1.8
Data Network Identification Code
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..4)  

wfX25PadDefaultCfgLenSubAddress 1.3.6.1.4.1.18.3.5.9.12.1.1.9
Length of X.121 subaddress
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..8  

wfX25PadDefaultCfgLCNLow 1.3.6.1.4.1.18.3.5.9.12.1.1.10
Lower range for logical channel numbers
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..4095  

wfX25PadDefaultCfgLCNHigh 1.3.6.1.4.1.18.3.5.9.12.1.1.11
Upper range for logical channel numbers
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..4095  

wfX25PadCurrentCfgTable 1.3.6.1.4.1.18.3.5.9.12.2
Table of X25 PAD Config Objects
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfX25PadCurrentCfgEntry

wfX25PadCurrentCfgEntry 1.3.6.1.4.1.18.3.5.9.12.2.1
An entry in the X25 Pad Config Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfX25PadCurrentCfgEntry  

wfX25PadCurrentCfgState 1.3.6.1.4.1.18.3.5.9.12.2.1.1
Current state of X.25 PAD sofware on the I-SDB
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), init(3)  

wfX25PadCurrentCfgSlot 1.3.6.1.4.1.18.3.5.9.12.2.1.2
Instance ID Slot, filled in by ISDB mib gate
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfX25PadCurrentCfgConnector 1.3.6.1.4.1.18.3.5.9.12.2.1.3
Instance ID Connector, filled in by ISDB mib gate. For the ASN this attribute is an encoded value and is equal to 'module'*10 + 'connector'. Where 'module' is defined in attribute 86 and 'connector' is defined in attribute 78 of this table. For non-ASN platforms this attribute is the physical connector number on the slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfX25PadCurrentCfgCircuit 1.3.6.1.4.1.18.3.5.9.12.2.1.4
Circuit number, filled in by ISDB mib gate
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfX25PadCurrentCfgX121Addr 1.3.6.1.4.1.18.3.5.9.12.2.1.5
X.121 address of the X.25 Pad
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..15)  

wfX25PadCurrentCfgDNIC 1.3.6.1.4.1.18.3.5.9.12.2.1.6
Data Network Identification Code
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..4)  

wfX25PadCurrentCfgLenSubAddress 1.3.6.1.4.1.18.3.5.9.12.2.1.7
Length of X.121 subaddress
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..8  

wfX25PadCurrentCfgLCNLow 1.3.6.1.4.1.18.3.5.9.12.2.1.8
Lower range for logical channel numbers
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4095  

wfX25PadCurrentCfgLCNHigh 1.3.6.1.4.1.18.3.5.9.12.2.1.9
Upper range for logical channel numbers
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4095  

wfX25PadStatTable 1.3.6.1.4.1.18.3.5.9.12.3
Table of X25 PAD Stat Objects
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfX25PadStatEntry

wfX25PadStatEntry 1.3.6.1.4.1.18.3.5.9.12.3.1
An entry in the X25 Pad Config Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfX25PadStatEntry  

wfX25PadStatState 1.3.6.1.4.1.18.3.5.9.12.3.1.1
Current state of X.25 PAD sofware on the I-SDB
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), init(3)  

wfX25PadStatSlot 1.3.6.1.4.1.18.3.5.9.12.3.1.2
Instance ID Slot, filled in by ISDB mib gate
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfX25PadStatConnector 1.3.6.1.4.1.18.3.5.9.12.3.1.3
Instance ID Connector, filled in by ISDB mib gate. For the ASN this attribute is an encoded value and is equal to 'module'*10 + 'connector'. Where 'module' is defined in attribute 86 and 'connector' is defined in attribute 78 of this table. For non-ASN platforms this attribute is the physical connector number on the slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfX25PadStatTotalConnCount 1.3.6.1.4.1.18.3.5.9.12.3.1.4
Total number of connections made to the X.25 Pad
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadStatRxRR 1.3.6.1.4.1.18.3.5.9.12.3.1.5
Number of receiver ready packets received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadStatTxRR 1.3.6.1.4.1.18.3.5.9.12.3.1.6
Number of receiver ready packets transmitted
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadStatRxRNR 1.3.6.1.4.1.18.3.5.9.12.3.1.7
Number of receiver not ready packets received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadStatTxRNR 1.3.6.1.4.1.18.3.5.9.12.3.1.8
Number of receiver not ready packets transmitted
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadStatRxRestart 1.3.6.1.4.1.18.3.5.9.12.3.1.9
Number of restart packets received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadStatTxRestart 1.3.6.1.4.1.18.3.5.9.12.3.1.10
Number of restart packets transmitted
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadPortDefaultCfgTable 1.3.6.1.4.1.18.3.5.9.12.4
Table of X25 PAD Port Config Objects
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfX25PadPortDefaultCfgEntry

wfX25PadPortDefaultCfgEntry 1.3.6.1.4.1.18.3.5.9.12.4.1
An entry in the X25 Pad Port Config Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfX25PadPortDefaultCfgEntry  

wfX25PadPortDefaultCfgDelete 1.3.6.1.4.1.18.3.5.9.12.4.1.1
Create/Delete parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfX25PadPortDefaultCfgDisable 1.3.6.1.4.1.18.3.5.9.12.4.1.2
Enable/Disable parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfX25PadPortDefaultCfgState 1.3.6.1.4.1.18.3.5.9.12.4.1.3
Current state of X.25 PAD sofware on the I-SDB
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), init(3)  

wfX25PadPortDefaultCfgSlot 1.3.6.1.4.1.18.3.5.9.12.4.1.4
Instance ID Slot, filled in by ISDB mib gate
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfX25PadPortDefaultCfgConnector 1.3.6.1.4.1.18.3.5.9.12.4.1.5
Instance ID Connector, filled in by ISDB mib gate. For the ASN this attribute is an encoded value and is equal to 'module'*10 + 'connector'. Where 'module' is defined in attribute 86 and 'connector' is defined in attribute 78 of this table. For non-ASN platforms this attribute is the physical connector number on the slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfX25PadPortDefaultCfgNumber 1.3.6.1.4.1.18.3.5.9.12.4.1.6
Instance ID Async Port, filled in by ISDB mib gate
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfX25PadPortDefaultCfgSubAddress 1.3.6.1.4.1.18.3.5.9.12.4.1.7
Subaddress portion of an X.121 address that is used by an application and is transparent to the network
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..8)  

wfX25PadPortDefaultCfgLenSubAddress 1.3.6.1.4.1.18.3.5.9.12.4.1.8
Size of the Subaddress portion of an X.121 address
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..8  

wfX25PadPortDefaultCfgX3escape 1.3.6.1.4.1.18.3.5.9.12.4.1.9
PAD recall using a character
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..126  

wfX25PadPortDefaultCfgX3echo 1.3.6.1.4.1.18.3.5.9.12.4.1.10
PAD echo
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2  

wfX25PadPortDefaultCfgX3forward 1.3.6.1.4.1.18.3.5.9.12.4.1.11
Selection of the data forwarding characters
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..126  

wfX25PadPortDefaultCfgX3idle 1.3.6.1.4.1.18.3.5.9.12.4.1.12
Selection of the idle timer delay
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

wfX25PadPortDefaultCfgX3device 1.3.6.1.4.1.18.3.5.9.12.4.1.13
Ancillary device control
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2  

wfX25PadPortDefaultCfgX3signals 1.3.6.1.4.1.18.3.5.9.12.4.1.14
Control of PAD service signals
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..5  

wfX25PadPortDefaultCfgX3break 1.3.6.1.4.1.18.3.5.9.12.4.1.15
Selection of operation of the PAD on receipt of the break signal
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..21  

wfX25PadPortDefaultCfgX3discard 1.3.6.1.4.1.18.3.5.9.12.4.1.16
Discard output
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

wfX25PadPortDefaultCfgX3CRpad 1.3.6.1.4.1.18.3.5.9.12.4.1.17
Padding after carriage return
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

wfX25PadPortDefaultCfgX3folding 1.3.6.1.4.1.18.3.5.9.12.4.1.18
Line folding
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

wfX25PadPortDefaultCfgX3speed 1.3.6.1.4.1.18.3.5.9.12.4.1.19
Binary speed
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..18  

wfX25PadPortDefaultCfgX3flow 1.3.6.1.4.1.18.3.5.9.12.4.1.20
Flow Control of the PAD by the start-stop mode DTE
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

wfX25PadPortDefaultCfgX3LFinsert 1.3.6.1.4.1.18.3.5.9.12.4.1.21
Linefeed insertion after carriage return
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..7  

wfX25PadPortDefaultCfgX3LFpad 1.3.6.1.4.1.18.3.5.9.12.4.1.22
Linefeed padding
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

wfX25PadPortDefaultCfgX3Edit 1.3.6.1.4.1.18.3.5.9.12.4.1.23
Editing
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

wfX25PadPortDefaultCfgX3Cdelete 1.3.6.1.4.1.18.3.5.9.12.4.1.24
Character delete
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

wfX25PadPortDefaultCfgX3Ldelete 1.3.6.1.4.1.18.3.5.9.12.4.1.25
Line delete
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

wfX25PadPortDefaultCfgX3Ldisplay 1.3.6.1.4.1.18.3.5.9.12.4.1.26
Line display
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

wfX25PadPortDefaultCfgX3Esignals 1.3.6.1.4.1.18.3.5.9.12.4.1.27
Editing PAD service signals
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..126  

wfX25PadPortDefaultCfgX3Mask 1.3.6.1.4.1.18.3.5.9.12.4.1.28
Echo mask
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

wfX25PadPortDefaultCfgX3parity 1.3.6.1.4.1.18.3.5.9.12.4.1.29
Parity treatment
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..3  

wfX25PadPortDefaultCfgX3page 1.3.6.1.4.1.18.3.5.9.12.4.1.30
Page wait
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

wfX25PadPortDefaultCfgLenUserData 1.3.6.1.4.1.18.3.5.9.12.4.1.31
Length of the user defined data
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16  

wfX25PadPortDefaultCfgUserData 1.3.6.1.4.1.18.3.5.9.12.4.1.32
User defined data field represented in hexadecimal
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

wfX25PadPortDefaultCfgLenRawFacilities 1.3.6.1.4.1.18.3.5.9.12.4.1.33
Length of the user defined facilities
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..63  

wfX25PadPortDefaultCfgRawFacilitiesData 1.3.6.1.4.1.18.3.5.9.12.4.1.34
User defined facilities filed represented in hexadecimal
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..63)  

wfX25PadPortDefaultCfgReverseCharge 1.3.6.1.4.1.18.3.5.9.12.4.1.35
If subscribed to, authorizes the DCE to transmit to the DTE incoming calls which request the reverse charging facility. In absence of this facility the DCE will not transmit to the DTE incoming calls which request the reverse charging facility.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..2)  

wfX25PadPortDefaultCfgThruClassNegotiation 1.3.6.1.4.1.18.3.5.9.12.4.1.36
This facility, if subscribed to, allows negotiation on a per call basis of the throughput classes. The throughput classes are considered independently for each direction of data transmission.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..2)  

wfX25PadPortDefaultCfgPacketSizeNegotiation 1.3.6.1.4.1.18.3.5.9.12.4.1.37
This facility, if subscribed to, will cause the DTE to request packet sizes for both directions of data transmission
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..3)  

wfX25PadPortDefaultCfgWindowSizeNegotiation 1.3.6.1.4.1.18.3.5.9.12.4.1.38
This facility, if subscribed to, will cause the DTE to request window sizes for both directions of data transmission
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..3)  

wfX25PadPortDefaultCfgIntervalTimer 1.3.6.1.4.1.18.3.5.9.12.4.1.39
Time (where 1 equals 10 milliseconds) that the X.25 PAD will wait before forwarding packets with characters in them
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..999  

wfX25PadPortDefaultCfgFullAddressing 1.3.6.1.4.1.18.3.5.9.12.4.1.40
Determines whether calling addresses should be included or not
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfX25PadPortCurrentCfgTable 1.3.6.1.4.1.18.3.5.9.12.5
Table of X25 PAD Port Config Objects
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfX25PadPortCurrentCfgEntry

wfX25PadPortCurrentCfgEntry 1.3.6.1.4.1.18.3.5.9.12.5.1
An entry in the X25 Pad Port Config Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfX25PadPortCurrentCfgEntry  

wfX25PadPortCurrentCfgState 1.3.6.1.4.1.18.3.5.9.12.5.1.1
Current state of X.25 PAD sofware on the I-SDB
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), init(3)  

wfX25PadPortCurrentCfgSlot 1.3.6.1.4.1.18.3.5.9.12.5.1.2
Instance ID Slot, filled in by ISDB mib gate
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfX25PadPortCurrentCfgConnector 1.3.6.1.4.1.18.3.5.9.12.5.1.3
Instance ID Connector, filled in by ISDB mib gate. For the ASN this attribute is an encoded value and is equal to 'module'*10 + 'connector'. Where 'module' is defined in attribute 86 and 'connector' is defined in attribute 78 of this table. For non-ASN platforms this attribute is the physical connector number on the slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfX25PadPortCurrentCfgNumber 1.3.6.1.4.1.18.3.5.9.12.5.1.4
Instance ID Async Port, filled in by ISDB mib gate
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfX25PadPortCurrentCfgSubAddress 1.3.6.1.4.1.18.3.5.9.12.5.1.5
Subaddress portion of an X.121 address that is used by an application and is transparent to the network
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

wfX25PadPortCurrentCfgLenSubAddress 1.3.6.1.4.1.18.3.5.9.12.5.1.6
Size of the Subaddress portion of an X.121 address
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..8  

wfX25PadPortCurrentCfgX3escape 1.3.6.1.4.1.18.3.5.9.12.5.1.7
PAD recall using a character
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..126  

wfX25PadPortCurrentCfgX3echo 1.3.6.1.4.1.18.3.5.9.12.5.1.8
PAD echo
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2  

wfX25PadPortCurrentCfgX3forward 1.3.6.1.4.1.18.3.5.9.12.5.1.9
Selection of the data forwarding characters
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..126  

wfX25PadPortCurrentCfgX3idle 1.3.6.1.4.1.18.3.5.9.12.5.1.10
Selection of the idle timer delay
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

wfX25PadPortCurrentCfgX3device 1.3.6.1.4.1.18.3.5.9.12.5.1.11
Ancillary device control
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2  

wfX25PadPortCurrentCfgX3signals 1.3.6.1.4.1.18.3.5.9.12.5.1.12
Control of PAD service signals
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..48  

wfX25PadPortCurrentCfgX3break 1.3.6.1.4.1.18.3.5.9.12.5.1.13
Selection of operation of the PAD on receipt of the break signal
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..21  

wfX25PadPortCurrentCfgX3discard 1.3.6.1.4.1.18.3.5.9.12.5.1.14
Discard output
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

wfX25PadPortCurrentCfgX3CRpad 1.3.6.1.4.1.18.3.5.9.12.5.1.15
Padding after carriage return
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

wfX25PadPortCurrentCfgX3folding 1.3.6.1.4.1.18.3.5.9.12.5.1.16
Line folding
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

wfX25PadPortCurrentCfgX3speed 1.3.6.1.4.1.18.3.5.9.12.5.1.17
Binary speed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..18  

wfX25PadPortCurrentCfgX3flow 1.3.6.1.4.1.18.3.5.9.12.5.1.18
Flow Control of the PAD by the start-stop mode DTE
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

wfX25PadPortCurrentCfgX3LFinsert 1.3.6.1.4.1.18.3.5.9.12.5.1.19
Linefeed insertion after carriage return
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..7  

wfX25PadPortCurrentCfgX3LFpad 1.3.6.1.4.1.18.3.5.9.12.5.1.20
Linefeed padding
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

wfX25PadPortCurrentCfgX3Edit 1.3.6.1.4.1.18.3.5.9.12.5.1.21
Editing
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

wfX25PadPortCurrentCfgX3Cdelete 1.3.6.1.4.1.18.3.5.9.12.5.1.22
Character delete
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..127  

wfX25PadPortCurrentCfgX3Ldelete 1.3.6.1.4.1.18.3.5.9.12.5.1.23
Line delete
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..127  

wfX25PadPortCurrentCfgX3Ldisplay 1.3.6.1.4.1.18.3.5.9.12.5.1.24
Line display
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..127  

wfX25PadPortCurrentCfgX3Esignals 1.3.6.1.4.1.18.3.5.9.12.5.1.25
Editing PAD service signals
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..126  

wfX25PadPortCurrentCfgX3Mask 1.3.6.1.4.1.18.3.5.9.12.5.1.26
Echo mask
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

wfX25PadPortCurrentCfgX3parity 1.3.6.1.4.1.18.3.5.9.12.5.1.27
Parity treatment
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..3  

wfX25PadPortCurrentCfgX3page 1.3.6.1.4.1.18.3.5.9.12.5.1.28
Page wait
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

wfX25PadPortCurrentCfgLenUserData 1.3.6.1.4.1.18.3.5.9.12.5.1.29
Length of the user defined data
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

wfX25PadPortCurrentCfgUserData 1.3.6.1.4.1.18.3.5.9.12.5.1.30
User defined data field represented in hexadecimal
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

wfX25PadPortCurrentCfgLenRawFacilities 1.3.6.1.4.1.18.3.5.9.12.5.1.31
Length of the user defined facilities
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..63  

wfX25PadPortCurrentCfgRawFacilitiesData 1.3.6.1.4.1.18.3.5.9.12.5.1.32
User defined facilities filed represented in hexadecimal
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..63)  

wfX25PadPortCurrentCfgReverseCharge 1.3.6.1.4.1.18.3.5.9.12.5.1.33
If subscribed to, authorizes the DCE to transmit to the DTE incoming calls which request the reverse charging facility. In absence of this facility the DCE will not transmit to the DTE incoming calls which request the reverse charging facility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..2)  

wfX25PadPortCurrentCfgThruClassNegotiation 1.3.6.1.4.1.18.3.5.9.12.5.1.34
This facility, if subscribed to, allows negotiation on a per call basis of the throughput classes. The throughput classes are considered independently for each direction of data transmission.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..2)  

wfX25PadPortCurrentCfgPacketSizeNegotiation 1.3.6.1.4.1.18.3.5.9.12.5.1.35
This facility, if subscribed to, will cause the DTE to request packet sizes for both directions of data transmission.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..3)  

wfX25PadPortCurrentCfgWindowSizeNegotiation 1.3.6.1.4.1.18.3.5.9.12.5.1.36
This facility, if subscribed to, will cause the DTE to request window sizes for both directions of data transmission.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..3)  

wfX25PadPortCurrentCfgIntervalTimer 1.3.6.1.4.1.18.3.5.9.12.5.1.37
Time (where 1 equals 10 milliseconds) that the X.25 PAD will wait before forwarding packets with characters in them
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..999  

wfX25PadPortCurrentCfgFullAddressing 1.3.6.1.4.1.18.3.5.9.12.5.1.38
Determines whether calling addresses should be included or not
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfX25PadPortStatTable 1.3.6.1.4.1.18.3.5.9.12.6
Table of X25 PAD Port Stat Objects
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfX25PadPortStatEntry

wfX25PadPortStatEntry 1.3.6.1.4.1.18.3.5.9.12.6.1
An entry in the X25 Pad Port Stat Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfX25PadPortStatEntry  

wfX25PadPortStatState 1.3.6.1.4.1.18.3.5.9.12.6.1.1
Current state of X.25 PAD sofware on the I-SDB
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), init(3)  

wfX25PadPortStatSlot 1.3.6.1.4.1.18.3.5.9.12.6.1.2
Instance ID Slot, filled in by ISDB mib gate
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfX25PadPortStatConnector 1.3.6.1.4.1.18.3.5.9.12.6.1.3
Instance ID Connector, filled in by ISDB mib gate. For the ASN this attribute is an encoded value and is equal to 'module'*10 + 'connector'. Where 'module' is defined in attribute 86 and 'connector' is defined in attribute 78 of this table. For non-ASN platforms this attribute is the physical connector number on the slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfX25PadPortStatNumber 1.3.6.1.4.1.18.3.5.9.12.6.1.4
Instance ID Async Port, filled in by ISDB mib gate
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfX25PadPortStatRxOctets 1.3.6.1.4.1.18.3.5.9.12.6.1.5
Number of octets received on this async port
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadPortStatTxOctets 1.3.6.1.4.1.18.3.5.9.12.6.1.6
Number of octets transmitted on this async port
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadPortStatRxPackets 1.3.6.1.4.1.18.3.5.9.12.6.1.7
Number of packets received on this async port
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadPortStatTxPackets 1.3.6.1.4.1.18.3.5.9.12.6.1.8
Number of packets transmitted on this async port
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadPortStatRemoteX121Addr 1.3.6.1.4.1.18.3.5.9.12.6.1.9
Remote X.121 address
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..15)  

wfX25PadPortStatLCN 1.3.6.1.4.1.18.3.5.9.12.6.1.10
Current connection's logical channel number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfX25PadPortStatDuration 1.3.6.1.4.1.18.3.5.9.12.6.1.11
Time in seconds of the call
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfX25PadPortStatRxRR 1.3.6.1.4.1.18.3.5.9.12.6.1.12
Number of receiver ready packets received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadPortStatTxRR 1.3.6.1.4.1.18.3.5.9.12.6.1.13
Number of receiver ready packets transmitted
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadPortStatRxRNR 1.3.6.1.4.1.18.3.5.9.12.6.1.14
Number of receiver not ready packets received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadPortStatTxRNR 1.3.6.1.4.1.18.3.5.9.12.6.1.15
Number of receiver not ready packets transmitted
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadPortStatRxClr 1.3.6.1.4.1.18.3.5.9.12.6.1.16
Number of call clear packets received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadPortStatTxClr 1.3.6.1.4.1.18.3.5.9.12.6.1.17
Number of call clear packets transmitted
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadPortStatRxReset 1.3.6.1.4.1.18.3.5.9.12.6.1.18
Number of reset packets received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadPortStatTxReset 1.3.6.1.4.1.18.3.5.9.12.6.1.19
Number of reset packets transmitted
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadPortStatRxCall 1.3.6.1.4.1.18.3.5.9.12.6.1.20
Number of call request packets received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadPortStatTxCall 1.3.6.1.4.1.18.3.5.9.12.6.1.21
Number of call request packets transmitted
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadPortStatConnections 1.3.6.1.4.1.18.3.5.9.12.6.1.22
Number of connections made
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadPortStatDisconnects 1.3.6.1.4.1.18.3.5.9.12.6.1.23
Number of disconnects made
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfX25PadPortStatLastCause 1.3.6.1.4.1.18.3.5.9.12.6.1.24
Last cause code
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfX25PadPortStatLastDiag 1.3.6.1.4.1.18.3.5.9.12.6.1.25
Last diag code
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER