Wellfleet-SIP-MIB

File: Wellfleet-SIP-MIB.mib (7519 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC-1215
RFC1213-MIB Wellfleet-COMMON-MIB

Imported symbols

IpAddress Counter Gauge
TimeTicks Opaque enterprises
mgmt OBJECT-TYPE TRAP-TYPE
DisplayString mib-2 wfSipGroup

Defined Types

WfSipL2Entry  
SEQUENCE    
  wfSipL2Index INTEGER
  wfSipL2ReceivedCounts Counter
  wfSipL2SentCounts Counter
  wfSipHcsOrCRCErrors Counter
  wfSipL2PayloadLengthErrors Counter
  wfSipL2SequenceNumberErrors Counter
  wfSipL2MidCurrentlyActiveErrors Counter
  wfSipL2BomOrSSMsMIDErrors Counter
  wfSipL2EomsMIDErrors Counter

WfSipDs1PlcpEntry  
SEQUENCE    
  wfSipDs1PlcpIndex INTEGER
  wfSipDs1PlcpSEFs Counter
  wfSipDs1PlcpAlarmState INTEGER
  wfSipDs1PlcpUASs Counter

WfSipDs3PlcpEntry  
SEQUENCE    
  wfSipDs3PlcpIndex INTEGER
  wfSipDs3PlcpSEFs Counter
  wfSipDs3PlcpAlarmState INTEGER
  wfSipDs3PlcpUASs Counter

Defined Values

wfSipPlcpGroup 1.3.6.1.4.1.18.3.4.14.2
OBJECT IDENTIFIER    

wfSipL2 1.3.6.1.4.1.18.3.4.14.1
The SIP L2 Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfSipL2Entry

wfSipL2Entry 1.3.6.1.4.1.18.3.4.14.1.1
per circuit SIP Level 2 objects - wfSipL2Index corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfSipL2Entry  

wfSipL2Index 1.3.6.1.4.1.18.3.4.14.1.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

wfSipL2ReceivedCounts 1.3.6.1.4.1.18.3.4.14.1.1.2
total of unerrored received SIP L2 PDUs
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfSipL2SentCounts 1.3.6.1.4.1.18.3.4.14.1.1.3
total of unerrored SIP L2 PDU's sent across the SNI
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfSipHcsOrCRCErrors 1.3.6.1.4.1.18.3.4.14.1.1.4
total SIP L2 PDUs with HCS or CRC errors
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfSipL2PayloadLengthErrors 1.3.6.1.4.1.18.3.4.14.1.1.5
total SIP L2 PDUs with length errors
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfSipL2SequenceNumberErrors 1.3.6.1.4.1.18.3.4.14.1.1.6
total SIP L2 PDUs with unexpected sequence numbers
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfSipL2MidCurrentlyActiveErrors 1.3.6.1.4.1.18.3.4.14.1.1.7
number of SIP L2 PDUs with BOMs previously started
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfSipL2BomOrSSMsMIDErrors 1.3.6.1.4.1.18.3.4.14.1.1.8
number of SIP L2 PDUs with zero BOMs or SSMs not zero
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfSipL2EomsMIDErrors 1.3.6.1.4.1.18.3.4.14.1.1.9
number of SIP L2 PDUs with zero EOMs or EOMs without BOMs
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfSipDs1Plcp 1.3.6.1.4.1.18.3.4.14.2.1
The SIP DS1 PLCP Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfSipDs1PlcpEntry

wfSipDs1PlcpEntry 1.3.6.1.4.1.18.3.4.14.2.1.1
per circuit DS1 PLCP objects - wfSipDs1PlcpIndex corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfSipDs1PlcpEntry  

wfSipDs1PlcpIndex 1.3.6.1.4.1.18.3.4.14.2.1.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

wfSipDs1PlcpSEFs 1.3.6.1.4.1.18.3.4.14.2.1.1.2
number of second intervals containing one or more severely errored seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfSipDs1PlcpAlarmState 1.3.6.1.4.1.18.3.4.14.2.1.1.3
alarm state
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noalarm(1), receivedfarendalarm(2), incominglof(3)  

wfSipDs1PlcpUASs 1.3.6.1.4.1.18.3.4.14.2.1.1.4
number of second intervals containing one or more unavailable seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfSipDs3Plcp 1.3.6.1.4.1.18.3.4.14.2.2
The SIP DS3 PLCP Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfSipDs3PlcpEntry

wfSipDs3PlcpEntry 1.3.6.1.4.1.18.3.4.14.2.2.1
per circuit DS3 PLCP objects - wfSipDs3PlcpIndex corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfSipDs3PlcpEntry  

wfSipDs3PlcpIndex 1.3.6.1.4.1.18.3.4.14.2.2.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

wfSipDs3PlcpSEFs 1.3.6.1.4.1.18.3.4.14.2.2.1.2
number of second intervals containing one or more severely errored seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfSipDs3PlcpAlarmState 1.3.6.1.4.1.18.3.4.14.2.2.1.3
alarm state
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noalarm(1), receivedfarendalarm(2), incominglof(3)  

wfSipDs3PlcpUASs 1.3.6.1.4.1.18.3.4.14.2.2.1.4
number of second intervals containing one or more unavailable seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter