Wellfleet-OSI-MIB

File: Wellfleet-OSI-MIB.mib (94745 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
Wellfleet-COMMON-MIB

Imported symbols

IpAddress Counter Opaque
OBJECT-TYPE DisplayString wfOsiGroup

Defined Types

WfOsiStaticRouteEntry  
SEQUENCE    
  wfOsiStaticRouteDelete INTEGER
  wfOsiStaticRouteDisable INTEGER
  wfOsiStaticRouteAddr OCTET STRING
  wfOsiStaticRouteNibbleLength INTEGER
  wfOsiStaticRouteNextHopIs OCTET STRING
  wfOsiStaticRouteType INTEGER
  wfOsiStaticRouteCost INTEGER

WfOsiCircuitEntry  
SEQUENCE    
  wfOsiCircuitDelete INTEGER
  wfOsiCircuitDisable INTEGER
  wfOsiCircuitState INTEGER
  wfOsiCircuitId INTEGER
  wfOsiCircuitRouterLevel INTEGER
  wfOsiCircuitL1DefaultMetric INTEGER
  wfOsiCircuitL2DefaultMetric INTEGER
  wfOsiCircuitL1DrPriority INTEGER
  wfOsiCircuitL2DrPriority INTEGER
  wfOsiCircuitIsisHelloTimer INTEGER
  wfOsiCircuitEsisHelloTimer INTEGER
  wfOsiCircuitEshConfigTime INTEGER
  wfOsiCircuitPassword DisplayString
  wfOsiCircuitReceivedPkts Counter
  wfOsiCircuitSentPkts Counter
  wfOsiCircuitDroppedPkts Counter
  wfOsiCircuitFragmentedPdus Counter
  wfOsiCircuitCongestionDiscards Counter
  wfOsiCircuitAddrUnreachDiscards Counter
  wfOsiCircuitAgedPduDiscards Counter
  wfOsiCircuitPduFormatErrDiscards Counter
  wfOsiCircuitUnsuppOptsDiscards Counter
  wfOsiCircuitSentErrorReports Counter
  wfOsiCircuitReceivedControlPdus Counter
  wfOsiCircuitSentControlPdus Counter
  wfOsiCircuitStateChanges Counter
  wfOsiCircuitAdjStateChanges Counter
  wfOsiCircuitInitFailures Counter
  wfOsiCircuitRejectedAdjs Counter
  wfOsiCircuitReceivedBadLsps Counter
  wfOsiCircuitReceivedBadSnps Counter
  wfOsiCircuitReceivedBadEshs Counter
  wfOsiCircuitReceivedBadL1Iihs Counter
  wfOsiCircuitReceivedBadL2Iihs Counter
  wfOsiCircuitL1DrChanges Counter
  wfOsiCircuitL2DrChanges Counter
  wfOsiCircuitClnpForwarding Counter
  wfOsiCircuitClnpDefaultLifeTime Counter
  wfOsiCircuitClnpInReceives Counter
  wfOsiCircuitClnpInAddrErrors Counter
  wfOsiCircuitClnpForwPdus Counter
  wfOsiCircuitClnpInUnknownNlps Counter
  wfOsiCircuitClnpInDelivers Counter
  wfOsiCircuitClnpInUnknownUlps Counter
  wfOsiCircuitClnpSegCreates Counter
  wfOsiCircuitClnpInOpts Counter
  wfOsiCircuitClnpOutOpts Counter
  wfOsiCircuitEsisEshIns Counter
  wfOsiCircuitEsisIshOuts Counter
  wfOsiCircuitEsisRduOuts Counter
  wfOsiCircuitL1DesignatedRouter OCTET STRING
  wfOsiCircuitL2DesignatedRouter OCTET STRING
  wfOsiCircuitClnpOutEchoReplies Counter
  wfOsiCircuitClnpOutEchoRequests Counter
  wfOsiCircuitClnpInEchoReplies Counter
  wfOsiCircuitClnpInEchoRequests Counter
  wfOsiCircuitNumDynEsAdjs Counter
  wfOsiCircuitNumDynL1Adjs Counter
  wfOsiCircuitNumDynL2Adjs Counter
  wfOsiCircuitNumDynPtpIsAdjs Counter
  wfOsiCircuitNumDynPtpEsAdjs Counter
  wfOsiCircuitBadIshReceived Counter
  wfOsiCircuitEsisIshIns Counter
  wfOsiCircuitIihHoldMultiplier INTEGER
  wfOsiCircuitIshHoldMultiplier INTEGER
  wfOsiCircuitDisableRedirect INTEGER

WfOsiExternalAddressEntry  
SEQUENCE    
  wfOsiExtAddrDelete INTEGER
  wfOsiExtAddrDisable INTEGER
  wfOsiExtAddr OCTET STRING
  wfOsiExtAddrCircuit INTEGER
  wfOsiExtAddrNibbleLength INTEGER
  wfOsiExtAddrSnpa OCTET STRING
  wfOsiExtAddrCost INTEGER

WfOsiStaticEsEntry  
SEQUENCE    
  wfOsiStaticEsDelete INTEGER
  wfOsiStaticEsDisable INTEGER
  wfOsiStaticEsId OCTET STRING
  wfOsiStaticEsCircuit INTEGER
  wfOsiStaticEsSnpa OCTET STRING

WfOsiTrafficFilterEntry  
SEQUENCE    
  wfOsiTrafficFilterDelete INTEGER
  wfOsiTrafficFilterDisable INTEGER
  wfOsiTrafficFilterStatus INTEGER
  wfOsiTrafficFilterCounter Counter
  wfOsiTrafficFilterDefinition Opaque
  wfOsiTrafficFilterReserved INTEGER
  wfOsiTrafficFilterCircuit INTEGER
  wfOsiTrafficFilterRuleNumber INTEGER
  wfOsiTrafficFilterFragment INTEGER
  wfOsiTrafficFilterName DisplayString

WfOsiL1LspHdrEntry  
SEQUENCE    
  wfOsiL1LspHdrLspId OCTET STRING
  wfOsiL1LspHdrLifetime INTEGER
  wfOsiL1LspHdrSeqnum INTEGER
  wfOsiL1LspHdrFlags OCTET STRING
  wfOsiL1LspHdrCksum OCTET STRING

WfOsiL2LspHdrEntry  
SEQUENCE    
  wfOsiL2LspHdrLspId OCTET STRING
  wfOsiL2LspHdrLifetime INTEGER
  wfOsiL2LspHdrSeqnum INTEGER
  wfOsiL2LspHdrFlags OCTET STRING
  wfOsiL2LspHdrCksum OCTET STRING

WfOsiDynAdjEntry  
SEQUENCE    
  wfOsiDynAdjId INTEGER
  wfOsiDynAdjDatabase INTEGER
  wfOsiDynAdjType INTEGER
  wfOsiDynAdjState INTEGER
  wfOsiDynAdjCircuitId INTEGER
  wfOsiDynAdjHoldTime INTEGER
  wfOsiDynAdjPriority INTEGER
  wfOsiDynAdjSnpaAddr OCTET STRING
  wfOsiDynAdjNsapAddr OCTET STRING
  wfOsiDynAdjLanId OCTET STRING

WfOsiL1RouteEntry  
SEQUENCE    
  wfOsiL1RouteId OCTET STRING
  wfOsiL1RoutePathSplit INTEGER
  wfOsiL1RouteType INTEGER
  wfOsiL1RouteNextHopSnpa OCTET STRING
  wfOsiL1RouteNextHopId OCTET STRING
  wfOsiL1RouteNextHopType INTEGER
  wfOsiL1RouteNextHopCircuit INTEGER
  wfOsiL1RouteDefaultMetricCost INTEGER

WfOsiL2RouteEntry  
SEQUENCE    
  wfOsiL2RouteId OCTET STRING
  wfOsiL2RoutePathSplit INTEGER
  wfOsiL2RouteType INTEGER
  wfOsiL2RouteNextHopSnpa OCTET STRING
  wfOsiL2RouteNextHopId OCTET STRING
  wfOsiL2RouteNextHopType INTEGER
  wfOsiL2RouteNextHopCircuit INTEGER
  wfOsiL2RouteDefaultMetricCost INTEGER

WfOsiAreaAddressEntry  
SEQUENCE    
  wfOsiAreaAddrDelete INTEGER
  wfOsiAreaAddrDisable INTEGER
  wfOsiAreaAddress OCTET STRING

WfOsiTarpCircuitEntry  
SEQUENCE    
  wfOsiTarpCircuitCreate INTEGER
  wfOsiTarpCircuitEnable INTEGER
  wfOsiTarpCircuitState INTEGER
  wfOsiTarpCircuitCct INTEGER
  wfOsiTarpCircuitPropagate INTEGER
  wfOsiTarpCircuitOriginate INTEGER
  wfOsiTarpCircuitType1Rcv Counter
  wfOsiTarpCircuitType1Xmt Counter
  wfOsiTarpCircuitType2Rcv Counter
  wfOsiTarpCircuitType2Xmt Counter
  wfOsiTarpCircuitType3Rcv Counter
  wfOsiTarpCircuitType3Xmt Counter
  wfOsiTarpCircuitType4Rcv Counter
  wfOsiTarpCircuitType4Xmt Counter
  wfOsiTarpCircuitType5Rcv Counter
  wfOsiTarpCircuitType5Xmt Counter
  wfOsiTarpCircuitNoBufs Counter

WfOsiTarpLDBEntry  
SEQUENCE    
  wfOsiTarpLDBCreate INTEGER
  wfOsiTarpLDBNSAP OCTET STRING
  wfOsiTarpLDBSequence INTEGER
  wfOsiTarpLDBCurrentTimer INTEGER

WfOsiTarpStaticAdjEntry  
SEQUENCE    
  wfOsiTarpStaticAdjCreate INTEGER
  wfOsiTarpStaticAdjEnable INTEGER
  wfOsiTarpStaticAdjNSAP OCTET STRING
  wfOsiTarpStaticNibbleLength INTEGER

WfOsiTarpIgnoreAdjEntry  
SEQUENCE    
  wfOsiTarpIgnoreAdjCreate INTEGER
  wfOsiTarpIgnoreAdjEnable INTEGER
  wfOsiTarpIgnoreAdjNSAP OCTET STRING
  wfOsiTarpIgnoreNibbleLength INTEGER

WfOsiGreAdjEntry  
SEQUENCE    
  wfOsiGreAdjDelete INTEGER
  wfOsiGreAdjDisable INTEGER
  wfOsiGreAdjTnlNum INTEGER
  wfOsiGreAdjConnNum INTEGER
  wfOsiGreAdjRemoteISId IpAddress
  wfOsiGreAdjCircuitId INTEGER

Defined Values

wfOsi 1.3.6.1.4.1.18.3.5.6.1
OBJECT IDENTIFIER    

wfOsiDelete 1.3.6.1.4.1.18.3.5.6.1.1
This value determines whether OSI is configured on this slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfOsiDisable 1.3.6.1.4.1.18.3.5.6.1.2
This value determines whether OSI is to startup.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiState 1.3.6.1.4.1.18.3.5.6.1.3
This value determines whether OSI is to startup.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), init(3), notpresent(4)  

wfOsiIsisVersion 1.3.6.1.4.1.18.3.5.6.1.4
This read-only parameter identifies the version number of the IS-IS protocol to which this node conforms to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

wfOsiRouterType 1.3.6.1.4.1.18.3.5.6.1.5
This value determines whether this system is an L1-only router or L1-L2 IS.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER l1only(1), l1l2(3)  

wfOsiRouterId 1.3.6.1.4.1.18.3.5.6.1.6
This value contains the system ID of this Intermediate System. If no value is entered by the user, Site Manager should supply a 6-byte value that will be unique (a MAC address would work).
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wfOsiLoadBal 1.3.6.1.4.1.18.3.5.6.1.7
This Boolean defines whether or not we are doing load balancing over multiple paths.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiMaxAreas 1.3.6.1.4.1.18.3.5.6.1.8
This value defines the maximum allowable number of areas addresses for the domain that this router exists in.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..1000  

wfOsiMaxEs 1.3.6.1.4.1.18.3.5.6.1.9
This value defines the maximum allowable number of End Systems for the area that this router exists in.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..4000  

wfOsiMaxL1Is 1.3.6.1.4.1.18.3.5.6.1.10
This value defines the maximum allowable number of L1 Intermediate Systems for the area that this router exists in.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..1000  

wfOsiMaxL2Is 1.3.6.1.4.1.18.3.5.6.1.11
This value defines the maximum allowable number of L2 Intermediate Systems for the domain that this router exists in.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..1000  

wfOsiMaxExtAddr 1.3.6.1.4.1.18.3.5.6.1.12
This value defines the maximum allowable number of External Addresses for the domain that this router exists in. The default value of this field is 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..500  

wfOsiCksumIsPdus 1.3.6.1.4.1.18.3.5.6.1.13
This value indicates whether ISIS PDUs will carry a checksum.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiL1LspPassword 1.3.6.1.4.1.18.3.5.6.1.14
This assigns a password such that only L1 Lsps with the matching password will be accepted. All L1 Lsps generated by this system will contain this string in the password option.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

wfOsiL2LspPassword 1.3.6.1.4.1.18.3.5.6.1.15
This assigns a password such that only L2 Lsps with the matching password will be accepted. All L2 Lsps generated by this system will contain this string in the password option.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

wfOsiAreaAddr 1.3.6.1.4.1.18.3.5.6.1.16
This Assigns the area address for this router. This field must be filled in. If the user doesn't enter a value, then assign 490040. Site Manager must force the user to enter at least a 3-byte value for this field.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wfOsiAreaAddrAlias1 1.3.6.1.4.1.18.3.5.6.1.17
This Assigns the first area address alias for this router. This field does no have to be filled in, but if the user tries to enter a value, Site Manager must make sure that it is at least 3-bytes in length.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wfOsiAreaAddrAlias2 1.3.6.1.4.1.18.3.5.6.1.18
This Assigns the second area address alias for this router. This field does no have to be filled in, but if the user tries to enter a value, Site Manager must make sure that it is at least 3-bytes in length.
Status: obsolete Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wfOsiCorruptedLsps 1.3.6.1.4.1.18.3.5.6.1.19
Number of Corrupted Lsps Detected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiL1LspDbOverloads 1.3.6.1.4.1.18.3.5.6.1.20
Number of times the L1 Lsp Database Overload event has been generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiL2LspDbOverloads 1.3.6.1.4.1.18.3.5.6.1.21
Number of times the L2 Lsp Database Overload event has been generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiManAddrDroppedAreas 1.3.6.1.4.1.18.3.5.6.1.22
Number of times the Manual Address Dropped from Area event has been generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiSeqNumberSkips 1.3.6.1.4.1.18.3.5.6.1.23
Number of times the Sequence Number Skipped event has been generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiOwnLspPurges 1.3.6.1.4.1.18.3.5.6.1.24
Number of times the Own Lsp Purged event has been generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiOthLspPurges 1.3.6.1.4.1.18.3.5.6.1.25
Number of times the Other Lsp Purged event has been generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiExceedMaxSeqNums 1.3.6.1.4.1.18.3.5.6.1.26
Number of times the Attempt tp Exceed Maximum Sequence Number event has been generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiNearestL2Is 1.3.6.1.4.1.18.3.5.6.1.27
This is the ID of the Nearest L2 system in this area.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wfOsiMaxDynEs 1.3.6.1.4.1.18.3.5.6.1.28
This is the maximum number of dynamically learned (via Hello) End Systems allowed per slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..4000  

wfOsiMaxDynL1Is 1.3.6.1.4.1.18.3.5.6.1.29
This is the maximum number of dynamically learned (via Hello) Level 1 Intermediate Systems allowed per slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..1000  

wfOsiMaxDynL2Is 1.3.6.1.4.1.18.3.5.6.1.30
This is the maximum number of dynamically learned (via Hello) Level 2 Intermediate Systems allowed per slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..1000  

wfOsiNumDynEsAdjs 1.3.6.1.4.1.18.3.5.6.1.31
Number of Dynamic ES adjs the osi master gate receives from the cct gate.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiNumDynL1Adjs 1.3.6.1.4.1.18.3.5.6.1.32
Number of Dynamic L1 adjs the osi master gate receives from the cct gate.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiNumDynL2Adjs 1.3.6.1.4.1.18.3.5.6.1.33
Number of Dynamic L2 adjs the osi master gate receives from the cct gate.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiNumL1Routes 1.3.6.1.4.1.18.3.5.6.1.34
Number of L1 Routes. WL 2.27.93
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiNumL2Routes 1.3.6.1.4.1.18.3.5.6.1.35
Number of L2 Routes. WL 2.27.93
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiNumDynPtpEsAdjs 1.3.6.1.4.1.18.3.5.6.1.36
Number of Dynamic Point-to-Point ES adjs the osi master gate receives on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiNumDynPtpIsAdjs 1.3.6.1.4.1.18.3.5.6.1.37
Number of Dynamic Point-to-Point IS adjs the osi master gate receives on .
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiClnpSrcRtOptionDisable 1.3.6.1.4.1.18.3.5.6.1.38
Enable/Disable processing of Source Route options in CLNP PDUs. This is required for GOSIP v2 support. GOSIP prohibits processing Source Routing options.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiNumL1Lsps 1.3.6.1.4.1.18.3.5.6.1.39
Number of L1 LSPs stored in database.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiNumL2Lsps 1.3.6.1.4.1.18.3.5.6.1.40
Number of L2 LSPs stored in database.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiFletchRelaxedEnable 1.3.6.1.4.1.18.3.5.6.1.41
Enable/Disable whether non-standard Fletcher Checksums are allowed in LSP's. If enabled, a log message will be generated, otherwise the LSP will be rejected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiStaticRouteTable 1.3.6.1.4.1.18.3.5.6.2
This table contains all the static routes for this system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfOsiStaticRouteEntry

wfOsiStaticRouteEntry 1.3.6.1.4.1.18.3.5.6.2.1
This is the Static Route Entry for the Static Route Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfOsiStaticRouteEntry  

wfOsiStaticRouteDelete 1.3.6.1.4.1.18.3.5.6.2.1.1
Create/Delete parameter for Osi Static Route Record.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfOsiStaticRouteDisable 1.3.6.1.4.1.18.3.5.6.2.1.2
Enable/Disable parameter for this Static Route.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiStaticRouteAddr 1.3.6.1.4.1.18.3.5.6.2.1.3
This specifies the address of the static route. It is also the inst_id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(20)  

wfOsiStaticRouteNibbleLength 1.3.6.1.4.1.18.3.5.6.2.1.4
This is the length in nibbles of the static route address. It is necessary to specify it in nibbles since the static route may be an external address which can be specified in nibbles.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wfOsiStaticRouteNextHopIs 1.3.6.1.4.1.18.3.5.6.2.1.5
This is the 6-octet ID of the next Hop IS that all data destined to wfOsiStaticRouteAddr will be forwarded to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wfOsiStaticRouteType 1.3.6.1.4.1.18.3.5.6.2.1.6
This specifies whether the destination is an End System, an area, or an external Domain.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER es(9), areaaddr(11), extaddr(13)  

wfOsiStaticRouteCost 1.3.6.1.4.1.18.3.5.6.2.1.7
This value is the cost to get to this address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..1023  

wfOsiCircuitTable 1.3.6.1.4.1.18.3.5.6.3
This Table contains all circuit configuration info counters available on a per circuit basis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfOsiCircuitEntry

wfOsiCircuitEntry 1.3.6.1.4.1.18.3.5.6.3.1
This is the circuit entry record that appears in the Circuit Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfOsiCircuitEntry  

wfOsiCircuitDelete 1.3.6.1.4.1.18.3.5.6.3.1.1
This value determines whether this circuit is configured.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfOsiCircuitDisable 1.3.6.1.4.1.18.3.5.6.3.1.2
Enable/Disable parameter for this circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiCircuitState 1.3.6.1.4.1.18.3.5.6.3.1.3
This indicates whether the circuit state is up or down.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2)  

wfOsiCircuitId 1.3.6.1.4.1.18.3.5.6.3.1.4
A unique value for each known circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiCircuitRouterLevel 1.3.6.1.4.1.18.3.5.6.3.1.5
This is the level protocol that the circuit runs. Its a bit mask to allow for some combination of L1, L2, External, ES-IS-only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER l1(1), l2(2), l1l2(3), ext(4), l2ext(6), l1l2ext(7), esisonly(8)  

wfOsiCircuitL1DefaultMetric 1.3.6.1.4.1.18.3.5.6.3.1.6
This is the default cost of using this circuit for L1 traffic.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..63  

wfOsiCircuitL2DefaultMetric 1.3.6.1.4.1.18.3.5.6.3.1.7
This is the default cost of using this circuit for L2 traffic.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..63  

wfOsiCircuitL1DrPriority 1.3.6.1.4.1.18.3.5.6.3.1.8
This is the priority for this system to become L1 designated router on this LAN circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

wfOsiCircuitL2DrPriority 1.3.6.1.4.1.18.3.5.6.3.1.9
This is the priority for this system to become L2 designated router on this LAN circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

wfOsiCircuitIsisHelloTimer 1.3.6.1.4.1.18.3.5.6.3.1.10
This is the period (secs) between IIH hello transmissions.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..3600  

wfOsiCircuitEsisHelloTimer 1.3.6.1.4.1.18.3.5.6.3.1.11
This is the period (secs) between ISH hello transmissions.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..3600  

wfOsiCircuitEshConfigTime 1.3.6.1.4.1.18.3.5.6.3.1.12
This is the suggested time between ESH transmissions from an ES went in ISHs (ESCT).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..3600  

wfOsiCircuitPassword 1.3.6.1.4.1.18.3.5.6.3.1.13
This is Circuit Password for this circuit. Used to filter out Hellos from systems without the correct password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

wfOsiCircuitReceivedPkts 1.3.6.1.4.1.18.3.5.6.3.1.14
This is the number of pkts that have been received on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitSentPkts 1.3.6.1.4.1.18.3.5.6.3.1.15
This is the number of pkts sent out this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitDroppedPkts 1.3.6.1.4.1.18.3.5.6.3.1.16
This is the number of pkts dropped on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitFragmentedPdus 1.3.6.1.4.1.18.3.5.6.3.1.17
This is the number of pdus that had to be fragmented when forwarded out this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitCongestionDiscards 1.3.6.1.4.1.18.3.5.6.3.1.18
This is the number of PDUs dropped because of congestion.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitAddrUnreachDiscards 1.3.6.1.4.1.18.3.5.6.3.1.19
This is the number of PDUs dropped because the destination is unreachable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitAgedPduDiscards 1.3.6.1.4.1.18.3.5.6.3.1.20
This is the number of PDUs dropped because of aging.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitPduFormatErrDiscards 1.3.6.1.4.1.18.3.5.6.3.1.21
This is the number of PDUs dropped because of Format Error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitUnsuppOptsDiscards 1.3.6.1.4.1.18.3.5.6.3.1.22
This is the number of PDUs dropped because they contain unsupported options.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitSentErrorReports 1.3.6.1.4.1.18.3.5.6.3.1.23
This is the number of error reports sent out this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitReceivedControlPdus 1.3.6.1.4.1.18.3.5.6.3.1.24
This is the number of ESIS or ISIS PDUs received on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitSentControlPdus 1.3.6.1.4.1.18.3.5.6.3.1.25
This is the number of ESIS or ISIS PDUs sent out this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitStateChanges 1.3.6.1.4.1.18.3.5.6.3.1.26
This is the number of times the circuit goes from down to up or from up to down.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitAdjStateChanges 1.3.6.1.4.1.18.3.5.6.3.1.27
This is the number of times an adjacency off of this circuit goes from down to up or from up to down state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitInitFailures 1.3.6.1.4.1.18.3.5.6.3.1.28
This is the number of times this circuit fails to initialize.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitRejectedAdjs 1.3.6.1.4.1.18.3.5.6.3.1.29
This is the number of Adjacencies that were rejected on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitReceivedBadLsps 1.3.6.1.4.1.18.3.5.6.3.1.30
This is the number of bad Lsps received on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitReceivedBadSnps 1.3.6.1.4.1.18.3.5.6.3.1.31
This is the number of BAD Sequence Number Pdus received on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitReceivedBadEshs 1.3.6.1.4.1.18.3.5.6.3.1.32
This is the number of bad ESHs received on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitReceivedBadL1Iihs 1.3.6.1.4.1.18.3.5.6.3.1.33
This is the number of bad L1 IIHs received on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitReceivedBadL2Iihs 1.3.6.1.4.1.18.3.5.6.3.1.34
This is the number of bad L2 IIHs received on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitL1DrChanges 1.3.6.1.4.1.18.3.5.6.3.1.35
This is the number of times the L1 Designated Router has been elected on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitL2DrChanges 1.3.6.1.4.1.18.3.5.6.3.1.36
This is the number of times the L2 Designated Router has been elected on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitClnpForwarding 1.3.6.1.4.1.18.3.5.6.3.1.37
This shows whether forwarding is enabled over this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitClnpDefaultLifeTime 1.3.6.1.4.1.18.3.5.6.3.1.38
This is the lifetime included in clnp pdus generated by this router (i.e. echo and echo reply pdus, error report pdus).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitClnpInReceives 1.3.6.1.4.1.18.3.5.6.3.1.39
This is the number of CLNP pdus received from this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitClnpInAddrErrors 1.3.6.1.4.1.18.3.5.6.3.1.40
This is the number of CLNP pdus recived from this circuit with Address format errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitClnpForwPdus 1.3.6.1.4.1.18.3.5.6.3.1.41
This is the number of Clnp PDUs received on this circuit that are forwarded.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitClnpInUnknownNlps 1.3.6.1.4.1.18.3.5.6.3.1.42
This is the number of Clnp PDUs received on this circuit where the network layer addressed is unknown (Bad NLPID).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitClnpInDelivers 1.3.6.1.4.1.18.3.5.6.3.1.43
This is the number of Clnp PDUs received on this circuit whose destination is this router.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitClnpInUnknownUlps 1.3.6.1.4.1.18.3.5.6.3.1.44
This is number of Clnp PDUs received on this circuit addressed to this router where the upper layer is unknown.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitClnpSegCreates 1.3.6.1.4.1.18.3.5.6.3.1.45
This is the number of CLNP segments created from pdus received on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitClnpInOpts 1.3.6.1.4.1.18.3.5.6.3.1.46
This is the number of CLNP pdus received with an options portion.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitClnpOutOpts 1.3.6.1.4.1.18.3.5.6.3.1.47
This is the number of CLNP pdus sent with an options portion.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitEsisEshIns 1.3.6.1.4.1.18.3.5.6.3.1.48
This is the number of ESHs received from this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitEsisIshOuts 1.3.6.1.4.1.18.3.5.6.3.1.49
This is the number of ISHs sent out this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitEsisRduOuts 1.3.6.1.4.1.18.3.5.6.3.1.50
This is the number of Redirects sent out this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitL1DesignatedRouter 1.3.6.1.4.1.18.3.5.6.3.1.51
This is the ID of the L1 Designated Router on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wfOsiCircuitL2DesignatedRouter 1.3.6.1.4.1.18.3.5.6.3.1.52
This is the ID of the L2 Designated Router on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wfOsiCircuitClnpOutEchoReplies 1.3.6.1.4.1.18.3.5.6.3.1.53
This is the number of CLNP Echo Replies sent out this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitClnpOutEchoRequests 1.3.6.1.4.1.18.3.5.6.3.1.54
This is the number of Clnp Echo Requests sent out this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitClnpInEchoReplies 1.3.6.1.4.1.18.3.5.6.3.1.55
This is the number of CLNP Echo Replies received on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitClnpInEchoRequests 1.3.6.1.4.1.18.3.5.6.3.1.56
This is the number of CLNP Echo Requests recived on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitNumDynEsAdjs 1.3.6.1.4.1.18.3.5.6.3.1.57
This is the number of Dynamic End System Adjacencies formed on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitNumDynL1Adjs 1.3.6.1.4.1.18.3.5.6.3.1.58
This is the number of Dynamic Level 1 Intermediate System Adjacencies formed on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitNumDynL2Adjs 1.3.6.1.4.1.18.3.5.6.3.1.59
This is the number of Dynamic Level 2 Intermediate System Adjacencies formed on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitNumDynPtpIsAdjs 1.3.6.1.4.1.18.3.5.6.3.1.60
This is the number of Dynamic Intermediate System Point-to-Point Adjacencies formed on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitNumDynPtpEsAdjs 1.3.6.1.4.1.18.3.5.6.3.1.61
This is the number of Dynamic End System Point-to-Point Adjaciences formed on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitBadIshReceived 1.3.6.1.4.1.18.3.5.6.3.1.62
This is the number of bad Intermediate System Hellos received on this circuit. These will only be received on Point-to-Point circuits.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitEsisIshIns 1.3.6.1.4.1.18.3.5.6.3.1.63
This is the number of good Intermediate System Hellos received on this circuit. These will only be received on Point-to-Point circuits.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiCircuitIihHoldMultiplier 1.3.6.1.4.1.18.3.5.6.3.1.64
This is the multiplier value used to compute the hold time set in the IIH PDUs transmitted from this router. Hold time equals IIH Timer times IIH Hold Multiplier.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..5  

wfOsiCircuitIshHoldMultiplier 1.3.6.1.4.1.18.3.5.6.3.1.65
This is the multiplier value used to compute the hold time set in the ISH PDUs transmitted from this router. Hold time equals IIH Timer times IIH Hold Multiplier.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..5  

wfOsiCircuitDisableRedirect 1.3.6.1.4.1.18.3.5.6.3.1.66
Allow Redirects to be disabled. This is required when operating over Frame Relay in group mode in a partial mesh topology.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiExternalAddressTable 1.3.6.1.4.1.18.3.5.6.4
This is the table of External Addresses for this Router.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfOsiExternalAddressEntry

wfOsiExternalAddressEntry 1.3.6.1.4.1.18.3.5.6.4.1
This is the External Address Record for this Router.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfOsiExternalAddressEntry  

wfOsiExtAddrDelete 1.3.6.1.4.1.18.3.5.6.4.1.1
This is the Create/Delete parameter for this ExtAddr entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfOsiExtAddrDisable 1.3.6.1.4.1.18.3.5.6.4.1.2
Enable/Disable parameter for this ExtAddr.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiExtAddr 1.3.6.1.4.1.18.3.5.6.4.1.3
This is the prefix external address. It is also the inst_id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(20)  

wfOsiExtAddrCircuit 1.3.6.1.4.1.18.3.5.6.4.1.4
This is the circuit to go out for this adj.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiExtAddrNibbleLength 1.3.6.1.4.1.18.3.5.6.4.1.5
This is the length in nibbles of the external address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wfOsiExtAddrSnpa 1.3.6.1.4.1.18.3.5.6.4.1.6
This is the SNPA of the neighbor on this circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wfOsiExtAddrCost 1.3.6.1.4.1.18.3.5.6.4.1.7
This is the external metric cost to this address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..63  

wfOsiStaticEsTable 1.3.6.1.4.1.18.3.5.6.5
This is the Static ES Table for this router.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfOsiStaticEsEntry

wfOsiStaticEsEntry 1.3.6.1.4.1.18.3.5.6.5.1
This is the Static ES entry for the Static ES Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfOsiStaticEsEntry  

wfOsiStaticEsDelete 1.3.6.1.4.1.18.3.5.6.5.1.1
This is the Create/Delete parameter for this Static ES entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfOsiStaticEsDisable 1.3.6.1.4.1.18.3.5.6.5.1.2
Enable/Disable parameter for this Static ES.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiStaticEsId 1.3.6.1.4.1.18.3.5.6.5.1.3
This is the ESID of the neighbor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

wfOsiStaticEsCircuit 1.3.6.1.4.1.18.3.5.6.5.1.4
This is the circuit to go out for this adj.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiStaticEsSnpa 1.3.6.1.4.1.18.3.5.6.5.1.5
This is the SNPA of the neighbor on this circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

wfOsiTrafficFilterTable 1.3.6.1.4.1.18.3.5.6.6
OSI Traffic Filters
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfOsiTrafficFilterEntry

wfOsiTrafficFilterEntry 1.3.6.1.4.1.18.3.5.6.6.1
A traffic filter definition
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfOsiTrafficFilterEntry  

wfOsiTrafficFilterDelete 1.3.6.1.4.1.18.3.5.6.6.1.1
Defines the existence of the traffic filter rule: created - traffic filter exists delete - traffic filter does not exist and can be deleted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfOsiTrafficFilterDisable 1.3.6.1.4.1.18.3.5.6.6.1.2
Defines whether or not the traffic filter rule should be used: enabled - activate the rule. disabled - inactivate the rule.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiTrafficFilterStatus 1.3.6.1.4.1.18.3.5.6.6.1.3
Defines the current status of the traffic filter: inactive - the rule is not in use. active - the rule is being used. error - the application detected an error in the rule.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), error(2), inactive(3)  

wfOsiTrafficFilterCounter 1.3.6.1.4.1.18.3.5.6.6.1.4
The number of received packets that have matched this rule.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTrafficFilterDefinition 1.3.6.1.4.1.18.3.5.6.6.1.5
The filter rule definition.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Opaque  

wfOsiTrafficFilterReserved 1.3.6.1.4.1.18.3.5.6.6.1.6
Reserved field.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiTrafficFilterCircuit 1.3.6.1.4.1.18.3.5.6.6.1.7
The ID of the Circuit to which the filter is applied.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiTrafficFilterRuleNumber 1.3.6.1.4.1.18.3.5.6.6.1.8
ID for the rule.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiTrafficFilterFragment 1.3.6.1.4.1.18.3.5.6.6.1.9
Fragment number - for large rules.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiTrafficFilterName 1.3.6.1.4.1.18.3.5.6.6.1.10
name of the rule number
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

wfOsiL1LspHdrTable 1.3.6.1.4.1.18.3.5.6.7
2 u_int32's so the inst_id len is 2.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfOsiL1LspHdrEntry

wfOsiL1LspHdrEntry 1.3.6.1.4.1.18.3.5.6.7.1
A Record in the Level 1 Lsp Header Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfOsiL1LspHdrEntry  

wfOsiL1LspHdrLspId 1.3.6.1.4.1.18.3.5.6.7.1.1
LSPID = Source ID + Pseudo-node ID + LSP number
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

wfOsiL1LspHdrLifetime 1.3.6.1.4.1.18.3.5.6.7.1.2
Lsp Lifetime
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiL1LspHdrSeqnum 1.3.6.1.4.1.18.3.5.6.7.1.3
Lsp sequence number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiL1LspHdrFlags 1.3.6.1.4.1.18.3.5.6.7.1.4
Flags: P/ATT/LSPDBOL/IS type
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wfOsiL1LspHdrCksum 1.3.6.1.4.1.18.3.5.6.7.1.5
Checksum
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wfOsiL2LspHdrTable 1.3.6.1.4.1.18.3.5.6.8
2 u_int32's so the inst_id len is 2.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfOsiL2LspHdrEntry

wfOsiL2LspHdrEntry 1.3.6.1.4.1.18.3.5.6.8.1
A Record in the Lsp Header Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfOsiL2LspHdrEntry  

wfOsiL2LspHdrLspId 1.3.6.1.4.1.18.3.5.6.8.1.1
LSPID = Source ID + Pseudo-node ID + LSP number
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

wfOsiL2LspHdrLifetime 1.3.6.1.4.1.18.3.5.6.8.1.2
Lsp Lifetime
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiL2LspHdrSeqnum 1.3.6.1.4.1.18.3.5.6.8.1.3
Lsp sequence number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiL2LspHdrFlags 1.3.6.1.4.1.18.3.5.6.8.1.4
Flags: P/ATT/LSPDBOL/IS type
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wfOsiL2LspHdrCksum 1.3.6.1.4.1.18.3.5.6.8.1.5
Checksum
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wfOsiDynAdjTable 1.3.6.1.4.1.18.3.5.6.9
Dynamic Adjacency Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfOsiDynAdjEntry

wfOsiDynAdjEntry 1.3.6.1.4.1.18.3.5.6.9.1
Adjacency Table - the real index is the adjacency id
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfOsiDynAdjEntry  

wfOsiDynAdjId 1.3.6.1.4.1.18.3.5.6.9.1.1
Index in the Adjacency Table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiDynAdjDatabase 1.3.6.1.4.1.18.3.5.6.9.1.2
Database into which the Adjacency is stored, 1=ES, 2=Level 1 IS, 3=Level 2 IS.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiDynAdjType 1.3.6.1.4.1.18.3.5.6.9.1.3
The type of adjacency. (see Osi_const.h)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiDynAdjState 1.3.6.1.4.1.18.3.5.6.9.1.4
The state of the adjacency. INITIALIZING, UP or FAILED
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiDynAdjCircuitId 1.3.6.1.4.1.18.3.5.6.9.1.5
A unique value for each known circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiDynAdjHoldTime 1.3.6.1.4.1.18.3.5.6.9.1.6
Hold Time received from neighbor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiDynAdjPriority 1.3.6.1.4.1.18.3.5.6.9.1.7
Priority to become designated router. IS only.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiDynAdjSnpaAddr 1.3.6.1.4.1.18.3.5.6.9.1.8
SNAP address for neighbor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wfOsiDynAdjNsapAddr 1.3.6.1.4.1.18.3.5.6.9.1.9
Neighbor address (NSAP).
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wfOsiDynAdjLanId 1.3.6.1.4.1.18.3.5.6.9.1.10
LAN ID from Designated Router. IS only.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wfOsiL1RoutesTable 1.3.6.1.4.1.18.3.5.6.10
This is the L1 Routes Table for this router.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfOsiL1RouteEntry

wfOsiL1RouteEntry 1.3.6.1.4.1.18.3.5.6.10.1
This is the L1 Route entry for the Routes Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfOsiL1RouteEntry  

wfOsiL1RouteId 1.3.6.1.4.1.18.3.5.6.10.1.1
This is the SysID of the L1 Destination.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

wfOsiL1RoutePathSplit 1.3.6.1.4.1.18.3.5.6.10.1.2
This assigns a number to each equal cost path to the destination. There can be up to 2 equal cost paths to a destination.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiL1RouteType 1.3.6.1.4.1.18.3.5.6.10.1.3
This tells what kind of a route this entry is.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiL1RouteNextHopSnpa 1.3.6.1.4.1.18.3.5.6.10.1.4
This is the SNPA of the next hop adj for this route.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wfOsiL1RouteNextHopId 1.3.6.1.4.1.18.3.5.6.10.1.5
This is the ID of the next hop adjacency to this route. If its just an ES then it is the 6byte System ID. If the next HOP is an IS then it is the NET.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wfOsiL1RouteNextHopType 1.3.6.1.4.1.18.3.5.6.10.1.6
This is the adj type of the next hop for this route.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiL1RouteNextHopCircuit 1.3.6.1.4.1.18.3.5.6.10.1.7
This is the circuit to forward out for this route.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiL1RouteDefaultMetricCost 1.3.6.1.4.1.18.3.5.6.10.1.8
This is the cost to from this system to this destination.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiL2RoutesTable 1.3.6.1.4.1.18.3.5.6.11
This is the L2 Routes Table for this router.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfOsiL2RouteEntry

wfOsiL2RouteEntry 1.3.6.1.4.1.18.3.5.6.11.1
This is the L2 Route entry for the Routes Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfOsiL2RouteEntry  

wfOsiL2RouteId 1.3.6.1.4.1.18.3.5.6.11.1.1
This is the SysID of the L2 Destination.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(13)  

wfOsiL2RoutePathSplit 1.3.6.1.4.1.18.3.5.6.11.1.2
This assigns a number to each equal cost path to the destination. There can be up to 2 equal cost paths to a destination.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiL2RouteType 1.3.6.1.4.1.18.3.5.6.11.1.3
This tells what kind of a route this entry is.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiL2RouteNextHopSnpa 1.3.6.1.4.1.18.3.5.6.11.1.4
This is the SNPA of the neighbor on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wfOsiL2RouteNextHopId 1.3.6.1.4.1.18.3.5.6.11.1.5
This is the ID of the next hop adjacency to this route. If its just an ES then it is the 6byte System ID. If the next HOP is an IS then it is the NET.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wfOsiL2RouteNextHopType 1.3.6.1.4.1.18.3.5.6.11.1.6
This is the adj type of the next hop for this route.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiL2RouteNextHopCircuit 1.3.6.1.4.1.18.3.5.6.11.1.7
This is the circuit to go out for this adj.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiL2RouteDefaultMetricCost 1.3.6.1.4.1.18.3.5.6.11.1.8
This is the cost to from this system to this destination.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiDecnetTrans 1.3.6.1.4.1.18.3.5.6.12
OBJECT IDENTIFIER    

wfOsiDecnetTransDelete 1.3.6.1.4.1.18.3.5.6.12.1
This value determines whether DECnet Phase 4 to Phase 5 Transition functions are configured.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfOsiDecnetTransDisable 1.3.6.1.4.1.18.3.5.6.12.2
This value determines whether DECnet Phase 4 to Phase 5 Transition functions are enabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiDecnetTransState 1.3.6.1.4.1.18.3.5.6.12.3
This value displays the state of the DECnet Phase 4 to Phase 5 Transition function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), init(3), notpresent(4)  

wfOsiDecnetTransPhase4Pkts 1.3.6.1.4.1.18.3.5.6.12.4
Number of successfully translated Phase 4 packets
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiDecnetTransSegFail 1.3.6.1.4.1.18.3.5.6.12.5
Number of times Phase 5 translation failed because the packet was segmented.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiDecnetTransNselFail 1.3.6.1.4.1.18.3.5.6.12.6
Number of times Phase 5 translation failed because the NSELs were not the same.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiDecnetTransUnrFail 1.3.6.1.4.1.18.3.5.6.12.7
Number of times Phase 5 failed to find a route to the destination.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiDecnetTransNumPhase4Es 1.3.6.1.4.1.18.3.5.6.12.8
Number of Phase 4 ES Adjacencies announced by the Phase 4 (DECnet IV) router.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiAreaAddressTable 1.3.6.1.4.1.18.3.5.6.13
This is the table of Area Addresses for this Router.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfOsiAreaAddressEntry

wfOsiAreaAddressEntry 1.3.6.1.4.1.18.3.5.6.13.1
This is the Area Address Record for this Router.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfOsiAreaAddressEntry  

wfOsiAreaAddrDelete 1.3.6.1.4.1.18.3.5.6.13.1.1
This is the Create/Delete parameter for this AreaAddr entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfOsiAreaAddrDisable 1.3.6.1.4.1.18.3.5.6.13.1.2
Enable/Disable parameter for this AreaAddr.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiAreaAddress 1.3.6.1.4.1.18.3.5.6.13.1.3
This is the prefix area address. It is also the inst_id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3..13)  

wfOsiTarpEntry 1.3.6.1.4.1.18.3.5.6.14
OBJECT IDENTIFIER    

wfOsiTarpCreate 1.3.6.1.4.1.18.3.5.6.14.1
This value determines whether OSI Tarp is configured on this slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfOsiTarpEnable 1.3.6.1.4.1.18.3.5.6.14.2
This value dtermines if OSI Tarp is to startup.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiTarpState 1.3.6.1.4.1.18.3.5.6.14.3
This value describes the state of OSI Tarp.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), init(3), notpresent(4)  

wfOsiTarpTID 1.3.6.1.4.1.18.3.5.6.14.4
This value contains the Target Identifier assigned to the router (Network Entity).
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

wfOsiTarpOriginate 1.3.6.1.4.1.18.3.5.6.14.5
This value determines if TARP is allowed to originate any tarp requests.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiTarpLifetime 1.3.6.1.4.1.18.3.5.6.14.6
This value determines what the lifetime of of TARP packets originated by this router will be.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wfOsiTarpStartSeq 1.3.6.1.4.1.18.3.5.6.14.7
This value determines what the starting sequence number of TARP packets originated by this router will be.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

wfOsiTarpNextSeq 1.3.6.1.4.1.18.3.5.6.14.8
This value determines what the next sequence number of TARP packets originated by this router will be.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

wfOsiTarpTarPro 1.3.6.1.4.1.18.3.5.6.14.9
This value describes what the Protocol Address Type field within the TARP packet must be. A value of 'FE' describes a CLNP address type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

wfOsiTarpTDC 1.3.6.1.4.1.18.3.5.6.14.10
This value determines whether or not TARP uses and maintains a Tarp Data Cache.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiTarpL2TDC 1.3.6.1.4.1.18.3.5.6.14.11
This value determines whether or not TARP uses and maintains a Level 2 Tarp Data Cache.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiTarpT1 1.3.6.1.4.1.18.3.5.6.14.12
This value configures the Tarp T1 Timer - how many seconds to wait for a response to a Type1 Request PDU.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..3600  

wfOsiTarpT2 1.3.6.1.4.1.18.3.5.6.14.13
This value configures the Tarp T2 Timer - how many seconds to wait for a response to a Type2 Request PDU.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..3600  

wfOsiTarpT3 1.3.6.1.4.1.18.3.5.6.14.14
This value configures the Tarp T3 Timer - how many seconds to wait for a response to a Type5 Request PDU.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..3600  

wfOsiTarpT4 1.3.6.1.4.1.18.3.5.6.14.15
This value configures the Tarp T4 Timer, which is used during the Error Recovery process after T2 expires.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..3600  

wfOsiTarpLDBTimer 1.3.6.1.4.1.18.3.5.6.14.16
This value configures the Loop Detection Buffer's Entry Timer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..600  

wfOsiTarpLDBFlush 1.3.6.1.4.1.18.3.5.6.14.17
This value configures the timer that signals the flushing of the Loop Detection Buffer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..86400  

wfOsiTarpLDBSize 1.3.6.1.4.1.18.3.5.6.14.18
This value specifies the maximum number of entries the the Loop Detection Buffer can hold.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..5000  

wfOsiTarpType1Rcv 1.3.6.1.4.1.18.3.5.6.14.19
This value counts the number of Type 1 Tarp packets received by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpType1Xmt 1.3.6.1.4.1.18.3.5.6.14.20
This value counts the number of Type 1 Tarp packets transmitted by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpType2Rcv 1.3.6.1.4.1.18.3.5.6.14.21
This value counts the number of Type 2 Tarp packets received by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpType2Xmt 1.3.6.1.4.1.18.3.5.6.14.22
This value counts the number of Type 2 Tarp packets transmitted by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpType3Rcv 1.3.6.1.4.1.18.3.5.6.14.23
This value counts the number of Type 3 Tarp packets received by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpType3Xmt 1.3.6.1.4.1.18.3.5.6.14.24
This value counts the number of Type 3 Tarp packets transmitted by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpType4Rcv 1.3.6.1.4.1.18.3.5.6.14.25
This value counts the number of Type 4 Tarp packets received by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpType4Xmt 1.3.6.1.4.1.18.3.5.6.14.26
This value counts the number of Type 4 Tarp packets transmitted by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpType5Rcv 1.3.6.1.4.1.18.3.5.6.14.27
This value counts the number of Type 5 Tarp packets received by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpType5Xmt 1.3.6.1.4.1.18.3.5.6.14.28
This value counts the number of Type 5 Tarp packets transmitted by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpCircuitTable 1.3.6.1.4.1.18.3.5.6.15
This table contains all of the Tarp interfaces for this system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfOsiTarpCircuitEntry

wfOsiTarpCircuitEntry 1.3.6.1.4.1.18.3.5.6.15.1
This is the Tarp Interface Entry for the Tarp Interface Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfOsiTarpCircuitEntry  

wfOsiTarpCircuitCreate 1.3.6.1.4.1.18.3.5.6.15.1.1
This value determines if the Tarp Interface is to be created for this OSI interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfOsiTarpCircuitEnable 1.3.6.1.4.1.18.3.5.6.15.1.2
This value determines if the Tarp Interface is to be enabled for this OSI interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiTarpCircuitState 1.3.6.1.4.1.18.3.5.6.15.1.3
This value reflects the state of the Tarp interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), init(3), notpresent(4)  

wfOsiTarpCircuitCct 1.3.6.1.4.1.18.3.5.6.15.1.4
Circuit number for this Tarp Interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiTarpCircuitPropagate 1.3.6.1.4.1.18.3.5.6.15.1.5
This value determines if this interface will propagate transit Tarp packets out this interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiTarpCircuitOriginate 1.3.6.1.4.1.18.3.5.6.15.1.6
This value determines if this interface will send out Tarp packets originated by the router.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiTarpCircuitType1Rcv 1.3.6.1.4.1.18.3.5.6.15.1.7
This value counts the number of Type 1 Tarp packets received by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpCircuitType1Xmt 1.3.6.1.4.1.18.3.5.6.15.1.8
This value counts the number of Type 1 Tarp packets transmitted by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpCircuitType2Rcv 1.3.6.1.4.1.18.3.5.6.15.1.9
This value counts the number of Type 2 Tarp packets received by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpCircuitType2Xmt 1.3.6.1.4.1.18.3.5.6.15.1.10
This value counts the number of Type 2 Tarp packets transmitted by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpCircuitType3Rcv 1.3.6.1.4.1.18.3.5.6.15.1.11
This value counts the number of Type 3 Tarp packets received by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpCircuitType3Xmt 1.3.6.1.4.1.18.3.5.6.15.1.12
This value counts the number of Type 3 Tarp packets transmitted by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpCircuitType4Rcv 1.3.6.1.4.1.18.3.5.6.15.1.13
This value counts the number of Type 4 Tarp packets received by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpCircuitType4Xmt 1.3.6.1.4.1.18.3.5.6.15.1.14
This value counts the number of Type 4 Tarp packets transmitted by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpCircuitType5Rcv 1.3.6.1.4.1.18.3.5.6.15.1.15
This value counts the number of Type 5 Tarp packets received by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpCircuitType5Xmt 1.3.6.1.4.1.18.3.5.6.15.1.16
This value counts the number of Type 5 Tarp packets transmitted by this interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpCircuitNoBufs 1.3.6.1.4.1.18.3.5.6.15.1.17
This value represents the number of times Tarp tried to allocate a buffer but was unable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfOsiTarpLDBTable 1.3.6.1.4.1.18.3.5.6.16
Table of wfOsiTarpLDBEntry's.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfOsiTarpLDBEntry

wfOsiTarpLDBEntry 1.3.6.1.4.1.18.3.5.6.16.1
Each entry in the Loop Detection Buffer.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfOsiTarpLDBEntry  

wfOsiTarpLDBCreate 1.3.6.1.4.1.18.3.5.6.16.1.1
Specifies the creation or deletion of the instance.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfOsiTarpLDBNSAP 1.3.6.1.4.1.18.3.5.6.16.1.2
The NSAP address for this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wfOsiTarpLDBSequence 1.3.6.1.4.1.18.3.5.6.16.1.3
The sequence number for this LDB entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

wfOsiTarpLDBCurrentTimer 1.3.6.1.4.1.18.3.5.6.16.1.4
Current timer for this LDB Entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..600  

wfOsiTarpStaticAdjTable 1.3.6.1.4.1.18.3.5.6.17
Table of wfOsiTarpStaticAdjEntry's.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfOsiTarpStaticAdjEntry

wfOsiTarpStaticAdjEntry 1.3.6.1.4.1.18.3.5.6.17.1
This is the static adjacency record that appears in the adjacency table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfOsiTarpStaticAdjEntry  

wfOsiTarpStaticAdjCreate 1.3.6.1.4.1.18.3.5.6.17.1.1
This value determines if this instance should be created or deleted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfOsiTarpStaticAdjEnable 1.3.6.1.4.1.18.3.5.6.17.1.2
This value determines if the Static Adjacency should be enabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiTarpStaticAdjNSAP 1.3.6.1.4.1.18.3.5.6.17.1.3
This specifies the address of the Static Adjacency. It is also the instance ID.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(20)  

wfOsiTarpStaticNibbleLength 1.3.6.1.4.1.18.3.5.6.17.1.4
Describes the number of nibbles in the Static NSAP Address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wfOsiTarpIgnoreAdjTable 1.3.6.1.4.1.18.3.5.6.18
This table contains all the adjacency entries that should be ignored.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfOsiTarpIgnoreAdjEntry

wfOsiTarpIgnoreAdjEntry 1.3.6.1.4.1.18.3.5.6.18.1
This is the ignore static route entry for the wfOsiTarpIgnoreAdj table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfOsiTarpIgnoreAdjEntry  

wfOsiTarpIgnoreAdjCreate 1.3.6.1.4.1.18.3.5.6.18.1.1
Signifies this instance should be created.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfOsiTarpIgnoreAdjEnable 1.3.6.1.4.1.18.3.5.6.18.1.2
This value determines if this instance should be enabled or disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiTarpIgnoreAdjNSAP 1.3.6.1.4.1.18.3.5.6.18.1.3
Identifies the OSI Adjacency that should be ignored.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(20)  

wfOsiTarpIgnoreNibbleLength 1.3.6.1.4.1.18.3.5.6.18.1.4
Describes the number of nibbles in the Static NSAP Address for the Ignore Static Route.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

wfOsiGreAdjTable 1.3.6.1.4.1.18.3.5.6.19
Gre Adjacency Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfOsiGreAdjEntry

wfOsiGreAdjEntry 1.3.6.1.4.1.18.3.5.6.19.1
GRE Adjacency Entry
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfOsiGreAdjEntry  

wfOsiGreAdjDelete 1.3.6.1.4.1.18.3.5.6.19.1.1
Delete/Create parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfOsiGreAdjDisable 1.3.6.1.4.1.18.3.5.6.19.1.2
Enable/Disable parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfOsiGreAdjTnlNum 1.3.6.1.4.1.18.3.5.6.19.1.3
GRE tunnel number from GRE MIB
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiGreAdjConnNum 1.3.6.1.4.1.18.3.5.6.19.1.4
GRE remote tunnel connection number from GRE MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfOsiGreAdjRemoteISId 1.3.6.1.4.1.18.3.5.6.19.1.5
This is the Physical IP address of the Destination.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

wfOsiGreAdjCircuitId 1.3.6.1.4.1.18.3.5.6.19.1.6
Circuit number on which this link in configured.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER