Wellfleet-DSX3-MIB

File: Wellfleet-DSX3-MIB.mib (87680 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
Wellfleet-COMMON-MIB

Imported symbols

Gauge OBJECT-TYPE DisplayString
wfDsx3Group

Defined Types

WfDsx3ConfigEntry  
SEQUENCE    
  wfDsx3LineIndex INTEGER
  wfDsx3IfIndex INTEGER
  wfDsx3TimeElapsed INTEGER
  wfDsx3ValidIntervals INTEGER
  wfDsx3LineType INTEGER
  wfDsx3LineCoding INTEGER
  wfDsx3SendCode INTEGER
  wfDsx3CircuitIdentifier DisplayString
  wfDsx3LoopbackConfig INTEGER
  wfDsx3LineStatus INTEGER
  wfDsx3TransmitClockSource INTEGER

WfDsx3CurrentEntry  
SEQUENCE    
  wfDsx3CurrentIndex INTEGER
  wfDsx3CurrentPESs Gauge
  wfDsx3CurrentPSESs Gauge
  wfDsx3CurrentSEFSs Gauge
  wfDsx3CurrentUASs Gauge
  wfDsx3CurrentLCVs Gauge
  wfDsx3CurrentPCVs Gauge
  wfDsx3CurrentLESs Gauge
  wfDsx3CurrentCCVs Gauge
  wfDsx3CurrentCESs Gauge
  wfDsx3CurrentCSESs Gauge
  wfDsx3CurrentSASs Gauge
  wfDsx3CurrentAISSs Gauge
  wfDsx3CurrentFCs Gauge
  wfDsx3CurrentTimeElapsed INTEGER
  wfDsx3CurrentValidIntervals INTEGER
  wfDsx3CurrentValidFlag INTEGER

WfDsx3IntervalEntry  
SEQUENCE    
  wfDsx3IntervalIndex INTEGER
  wfDsx3IntervalNumber INTEGER
  wfDsx3IntervalPESs Gauge
  wfDsx3IntervalPSESs Gauge
  wfDsx3IntervalSEFSs Gauge
  wfDsx3IntervalUASs Gauge
  wfDsx3IntervalLCVs Gauge
  wfDsx3IntervalPCVs Gauge
  wfDsx3IntervalLESs Gauge
  wfDsx3IntervalCCVs Gauge
  wfDsx3IntervalCESs Gauge
  wfDsx3IntervalCSESs Gauge
  wfDsx3IntervalSASs Gauge
  wfDsx3IntervalAISSs Gauge
  wfDsx3IntervalFCs Gauge
  wfDsx3IntervalValidFlag INTEGER

WfDsx3TotalEntry  
SEQUENCE    
  wfDsx3TotalIndex INTEGER
  wfDsx3TotalPESs Gauge
  wfDsx3TotalPSESs Gauge
  wfDsx3TotalSEFSs Gauge
  wfDsx3TotalUASs Gauge
  wfDsx3TotalLCVs Gauge
  wfDsx3TotalPCVs Gauge
  wfDsx3TotalLESs Gauge
  wfDsx3TotalCCVs Gauge
  wfDsx3TotalCESs Gauge
  wfDsx3TotalCSESs Gauge
  wfDsx3TotalSASs Gauge
  wfDsx3TotalAISSs Gauge
  wfDsx3TotalFCs Gauge
  wfDsx3TotalValidFlag INTEGER

WfDsx3FarEndConfigEntry  
SEQUENCE    
  wfDsx3FarEndLineIndex INTEGER
  wfDsx3FarEndEquipCode DisplayString
  wfDsx3FarEndLocationIDCode DisplayString
  wfDsx3FarEndFrameIDCode DisplayString
  wfDsx3FarEndUnitCode DisplayString
  wfDsx3FarEndFacilityIDCode DisplayString

WfDsx3FarEndCurrentEntry  
SEQUENCE    
  wfDsx3FarEndCurrentIndex INTEGER
  wfDsx3FarEndTimeElapsed INTEGER
  wfDsx3FarEndValidIntervals INTEGER
  wfDsx3FarEndCurrentCESs Gauge
  wfDsx3FarEndCurrentCSESs Gauge
  wfDsx3FarEndCurrentCCVs Gauge
  wfDsx3FarEndCurrentUASs Gauge
  wfDsx3FarEndCurrentSASs Gauge
  wfDsx3FarEndCurrentFCs Gauge
  wfDsx3FarEndCurrentValidFlag INTEGER

WfDsx3FarEndIntervalEntry  
SEQUENCE    
  wfDsx3FarEndIntervalIndex INTEGER
  wfDsx3FarEndIntervalNumber INTEGER
  wfDsx3FarEndIntervalCESs Gauge
  wfDsx3FarEndIntervalCSESs Gauge
  wfDsx3FarEndIntervalCCVs Gauge
  wfDsx3FarEndIntervalUASs Gauge
  wfDsx3FarEndIntervalSASs Gauge
  wfDsx3FarEndIntervalFCs Gauge
  wfDsx3FarEndIntervalValidFlag INTEGER

WfDsx3FarEndTotalEntry  
SEQUENCE    
  wfDsx3FarEndTotalIndex INTEGER
  wfDsx3FarEndTotalCESs Gauge
  wfDsx3FarEndTotalCSESs Gauge
  wfDsx3FarEndTotalCCVs Gauge
  wfDsx3FarEndTotalUASs Gauge
  wfDsx3FarEndTotalSASs Gauge
  wfDsx3FarEndTotalFCs Gauge
  wfDsx3FarEndTotalValidFlag INTEGER

WfAtmInterfaceDs3PlcpEntry  
SEQUENCE    
  wfAtmInterfaceDs3PlcpIndex INTEGER
  wfAtmInterfaceDs3PlcpSEFSs Gauge
  wfAtmInterfaceDs3PlcpAlarmState INTEGER
  wfAtmInterfaceDs3PlcpUASs Gauge

WfDsx3DayCurrentEntry  
SEQUENCE    
  wfDsx3DayCurrentIndex INTEGER
  wfDsx3DayCurrentPESs Gauge
  wfDsx3DayCurrentPSESs Gauge
  wfDsx3DayCurrentSEFSs Gauge
  wfDsx3DayCurrentUASs Gauge
  wfDsx3DayCurrentLCVs Gauge
  wfDsx3DayCurrentPCVs Gauge
  wfDsx3DayCurrentLESs Gauge
  wfDsx3DayCurrentCCVs Gauge
  wfDsx3DayCurrentCESs Gauge
  wfDsx3DayCurrentCSESs Gauge
  wfDsx3DayCurrentSASs Gauge
  wfDsx3DayCurrentAISSs Gauge
  wfDsx3DayCurrentFCs Gauge
  wfDsx3DayCurrentTimeElapsed INTEGER
  wfDsx3DayCurrentValidIntervals INTEGER
  wfDsx3DayCurrentValidFlag INTEGER

WfDsx3DayIntervalEntry  
SEQUENCE    
  wfDsx3DayIntervalIndex INTEGER
  wfDsx3DayIntervalNumber INTEGER
  wfDsx3DayIntervalPESs Gauge
  wfDsx3DayIntervalPSESs Gauge
  wfDsx3DayIntervalSEFSs Gauge
  wfDsx3DayIntervalUASs Gauge
  wfDsx3DayIntervalLCVs Gauge
  wfDsx3DayIntervalPCVs Gauge
  wfDsx3DayIntervalLESs Gauge
  wfDsx3DayIntervalCCVs Gauge
  wfDsx3DayIntervalCESs Gauge
  wfDsx3DayIntervalCSESs Gauge
  wfDsx3DayIntervalSASs Gauge
  wfDsx3DayIntervalAISSs Gauge
  wfDsx3DayIntervalFCs Gauge
  wfDsx3DayIntervalValidFlag INTEGER

WfDsx3DayTotalEntry  
SEQUENCE    
  wfDsx3DayTotalIndex INTEGER
  wfDsx3DayTotalPESs Gauge
  wfDsx3DayTotalPSESs Gauge
  wfDsx3DayTotalSEFSs Gauge
  wfDsx3DayTotalUASs Gauge
  wfDsx3DayTotalLCVs Gauge
  wfDsx3DayTotalPCVs Gauge
  wfDsx3DayTotalLESs Gauge
  wfDsx3DayTotalCCVs Gauge
  wfDsx3DayTotalCESs Gauge
  wfDsx3DayTotalCSESs Gauge
  wfDsx3DayTotalSASs Gauge
  wfDsx3DayTotalAISSs Gauge
  wfDsx3DayTotalFCs Gauge
  wfDsx3DayTotalValidFlag INTEGER

WfDsx3FarEndDayCurrentEntry  
SEQUENCE    
  wfDsx3FarEndDayCurrentIndex INTEGER
  wfDsx3FarEndDayTimeElapsed INTEGER
  wfDsx3FarEndDayValidIntervals INTEGER
  wfDsx3FarEndDayCurrentCESs Gauge
  wfDsx3FarEndDayCurrentCSESs Gauge
  wfDsx3FarEndDayCurrentCCVs Gauge
  wfDsx3FarEndDayCurrentUASs Gauge
  wfDsx3FarEndDayCurrentSASs Gauge
  wfDsx3FarEndDayCurrentFCs Gauge
  wfDsx3FarEndDayCurrentValidFlag INTEGER

WfDsx3FarEndDayIntervalEntry  
SEQUENCE    
  wfDsx3FarEndDayIntervalIndex INTEGER
  wfDsx3FarEndDayIntervalNumber INTEGER
  wfDsx3FarEndDayIntervalCESs Gauge
  wfDsx3FarEndDayIntervalCSESs Gauge
  wfDsx3FarEndDayIntervalCCVs Gauge
  wfDsx3FarEndDayIntervalUASs Gauge
  wfDsx3FarEndDayIntervalSASs Gauge
  wfDsx3FarEndDayIntervalFCs Gauge
  wfDsx3FarEndDayIntervalValidFlag INTEGER

WfDsx3FarEndDayTotalEntry  
SEQUENCE    
  wfDsx3FarEndDayTotalIndex INTEGER
  wfDsx3FarEndDayTotalCESs Gauge
  wfDsx3FarEndDayTotalCSESs Gauge
  wfDsx3FarEndDayTotalCCVs Gauge
  wfDsx3FarEndDayTotalUASs Gauge
  wfDsx3FarEndDayTotalSASs Gauge
  wfDsx3FarEndDayTotalFCs Gauge
  wfDsx3FarEndDayTotalValidFlag INTEGER

WfDsx3ThrAlrtEntry  
SEQUENCE    
  wfDsx3ThrAlrtDelete INTEGER
  wfDsx3ThrAlrtIndex INTEGER
  wfDsx3ThrAlrtPESs Gauge
  wfDsx3ThrAlrtPSESs Gauge
  wfDsx3ThrAlrtSEFSs Gauge
  wfDsx3ThrAlrtUASs Gauge
  wfDsx3ThrAlrtLCVs Gauge
  wfDsx3ThrAlrtPCVs Gauge
  wfDsx3ThrAlrtLESs Gauge
  wfDsx3ThrAlrtCCVs Gauge
  wfDsx3ThrAlrtCESs Gauge
  wfDsx3ThrAlrtCSESs Gauge
  wfDsx3ThrAlrtSASs Gauge
  wfDsx3ThrAlrtAISSs Gauge
  wfDsx3ThrAlrtFCs Gauge

WfDsx3FarEndThrAlrtEntry  
SEQUENCE    
  wfDsx3FarEndThrAlrtDelete INTEGER
  wfDsx3FarEndThrAlrtIndex INTEGER
  wfDsx3FarEndThrAlrtCESs Gauge
  wfDsx3FarEndThrAlrtCSESs Gauge
  wfDsx3FarEndThrAlrtCCVs Gauge
  wfDsx3FarEndThrAlrtUASs Gauge
  wfDsx3FarEndThrAlrtSASs Gauge
  wfDsx3FarEndThrAlrtFCs Gauge

WfDsx3DayThrAlrtEntry  
SEQUENCE    
  wfDsx3DayThrAlrtDelete INTEGER
  wfDsx3DayThrAlrtIndex INTEGER
  wfDsx3DayThrAlrtPESs Gauge
  wfDsx3DayThrAlrtPSESs Gauge
  wfDsx3DayThrAlrtSEFSs Gauge
  wfDsx3DayThrAlrtUASs Gauge
  wfDsx3DayThrAlrtLCVs Gauge
  wfDsx3DayThrAlrtPCVs Gauge
  wfDsx3DayThrAlrtLESs Gauge
  wfDsx3DayThrAlrtCCVs Gauge
  wfDsx3DayThrAlrtCESs Gauge
  wfDsx3DayThrAlrtCSESs Gauge
  wfDsx3DayThrAlrtSASs Gauge
  wfDsx3DayThrAlrtAISSs Gauge
  wfDsx3DayThrAlrtFCs Gauge

WfDsx3FarEndDayThrAlrtEntry  
SEQUENCE    
  wfDsx3FarEndDayThrAlrtDelete INTEGER
  wfDsx3FarEndDayThrAlrtIndex INTEGER
  wfDsx3FarEndDayThrAlrtCESs Gauge
  wfDsx3FarEndDayThrAlrtCSESs Gauge
  wfDsx3FarEndDayThrAlrtCCVs Gauge
  wfDsx3FarEndDayThrAlrtUASs Gauge
  wfDsx3FarEndDayThrAlrtSASs Gauge
  wfDsx3FarEndDayThrAlrtFCs Gauge

Defined Values

wfDsx3ConfigTable 1.3.6.1.4.1.18.3.4.26.1
The DS3/E3 Configuration table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDsx3ConfigEntry

wfDsx3ConfigEntry 1.3.6.1.4.1.18.3.4.26.1.1
per circuit DS3/E3 configuration objects; wfDsx3LineIndex corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDsx3ConfigEntry  

wfDsx3LineIndex 1.3.6.1.4.1.18.3.4.26.1.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wfDsx3IfIndex 1.3.6.1.4.1.18.3.4.26.1.1.2
this is value of ifIndex from the Interfaces table of MIB II (RFC 1213).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfDsx3TimeElapsed 1.3.6.1.4.1.18.3.4.26.1.1.3
0..899 seconds elapsed within the current 15-minute interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfDsx3ValidIntervals 1.3.6.1.4.1.18.3.4.26.1.1.4
0..96 previous intervals that valid data were collected. This is 96 unless the device was brought on line within the last 24 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfDsx3LineType 1.3.6.1.4.1.18.3.4.26.1.1.5
the variety of DS3/E3 application implementing this circuit
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ds3other(1), ds3m23(2), ds3syntran(3), ds3cbitparity(4), ds3clearchannel(5), e3other(6), e3framed(7), e3plcp(8)  

wfDsx3LineCoding 1.3.6.1.4.1.18.3.4.26.1.1.6
the variety of Zero Code Suppression used on the link
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), b3zs(2), hdb3(3)  

wfDsx3SendCode 1.3.6.1.4.1.18.3.4.26.1.1.7
the type of code being sent across the DS3/E3 circuit by the device
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER nocode(1), linecode(2), payloadcode(3), resetcode(4), ds1loopcode(5), testpattern(6)  

wfDsx3CircuitIdentifier 1.3.6.1.4.1.18.3.4.26.1.1.8
the transmission vendor's circuit identifier
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

wfDsx3LoopbackConfig 1.3.6.1.4.1.18.3.4.26.1.1.9
the loopback configuration of the DS3/E3 interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noloop(1), payloadloop(2), lineloop(3), otherloop(4)  

wfDsx3LineStatus 1.3.6.1.4.1.18.3.4.26.1.1.10
the status of the DS3/E3 line
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noalarm(1), rcrai(2), txrai(4), rcais(8), txais(16), lof(32), los(64), loopback(128), rctestcode(256), otherfailure(512)  

wfDsx3TransmitClockSource 1.3.6.1.4.1.18.3.4.26.1.1.11
the source of Transmit Clock for the DS3/E3 interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER looptiming(1), localtiming(2), throughtiming(3)  

wfDsx3CurrentTable 1.3.6.1.4.1.18.3.4.26.2
The DS3/E3 Current table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDsx3CurrentEntry

wfDsx3CurrentEntry 1.3.6.1.4.1.18.3.4.26.2.1
per circuit DS3/E3 current objects - wfDsx3CurrentIndex corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDsx3CurrentEntry  

wfDsx3CurrentIndex 1.3.6.1.4.1.18.3.4.26.2.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wfDsx3CurrentPESs 1.3.6.1.4.1.18.3.4.26.2.1.2
the number of P-bit Errored Seconds in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3CurrentPSESs 1.3.6.1.4.1.18.3.4.26.2.1.3
the number of P-bit Severely Errored Seconds in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3CurrentSEFSs 1.3.6.1.4.1.18.3.4.26.2.1.4
the number of Severely Errored Framing Seconds in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3CurrentUASs 1.3.6.1.4.1.18.3.4.26.2.1.5
the number of Unavailable Seconds in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3CurrentLCVs 1.3.6.1.4.1.18.3.4.26.2.1.6
the number of Line Coding Violations in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3CurrentPCVs 1.3.6.1.4.1.18.3.4.26.2.1.7
the number of P-bit Coding Violations in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3CurrentLESs 1.3.6.1.4.1.18.3.4.26.2.1.8
the number of Line Errored Seconds in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3CurrentCCVs 1.3.6.1.4.1.18.3.4.26.2.1.9
the number of C-bit Coding Violations in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3CurrentCESs 1.3.6.1.4.1.18.3.4.26.2.1.10
the number of C-bit Errored Seconds in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3CurrentCSESs 1.3.6.1.4.1.18.3.4.26.2.1.11
the number of C-bit Severely Errored Seconds in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3CurrentSASs 1.3.6.1.4.1.18.3.4.26.2.1.12
the number of Seconds containing one or more SEFs or AIS defects in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3CurrentAISSs 1.3.6.1.4.1.18.3.4.26.2.1.13
the number of Seconds containing one or more AIS defect in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3CurrentFCs 1.3.6.1.4.1.18.3.4.26.2.1.14
the number of Path Failure Count error events detected in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3CurrentTimeElapsed 1.3.6.1.4.1.18.3.4.26.2.1.15
the number of seconds since the beginning of the far end current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfDsx3CurrentValidIntervals 1.3.6.1.4.1.18.3.4.26.2.1.16
the number of previous far end intervals for which valid data is available
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfDsx3CurrentValidFlag 1.3.6.1.4.1.18.3.4.26.2.1.17
Indicates whether this interval reported by the Mib Table is valid or invalid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

wfDsx3IntervalTable 1.3.6.1.4.1.18.3.4.26.3
The DS3/E3 Interval table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDsx3IntervalEntry

wfDsx3IntervalEntry 1.3.6.1.4.1.18.3.4.26.3.1
per circuit DS3/E3 interval objects - wfDsx3IntervalIndex corresponds to Wellfleet circuit number, wfDsx3IntervalNumber is the numbered previous 15-minute interval
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDsx3IntervalEntry  

wfDsx3IntervalIndex 1.3.6.1.4.1.18.3.4.26.3.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wfDsx3IntervalNumber 1.3.6.1.4.1.18.3.4.26.3.1.2
1..96 where 1 is the most recent 15-minute interval and 96 is the least
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..96  

wfDsx3IntervalPESs 1.3.6.1.4.1.18.3.4.26.3.1.3
the number of P-bit Errored Seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3IntervalPSESs 1.3.6.1.4.1.18.3.4.26.3.1.4
the number of P-bit Severely Errored Seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3IntervalSEFSs 1.3.6.1.4.1.18.3.4.26.3.1.5
the number of Severely Errored Framing Seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3IntervalUASs 1.3.6.1.4.1.18.3.4.26.3.1.6
the number of Unavailable Seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3IntervalLCVs 1.3.6.1.4.1.18.3.4.26.3.1.7
the number of Line Coding Violations in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3IntervalPCVs 1.3.6.1.4.1.18.3.4.26.3.1.8
the number of P-bit Coding Violations in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3IntervalLESs 1.3.6.1.4.1.18.3.4.26.3.1.9
the number of Line Errored Seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3IntervalCCVs 1.3.6.1.4.1.18.3.4.26.3.1.10
the number of C-bit Coding Violations in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3IntervalCESs 1.3.6.1.4.1.18.3.4.26.3.1.11
the number of C-bit Errored Seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3IntervalCSESs 1.3.6.1.4.1.18.3.4.26.3.1.12
the number of C-bit Severely Errored Seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3IntervalSASs 1.3.6.1.4.1.18.3.4.26.3.1.13
the number of Seconds containing one or more SEFs or AIS defects in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3IntervalAISSs 1.3.6.1.4.1.18.3.4.26.3.1.14
the number of Seconds containing one or more AIS defect in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3IntervalFCs 1.3.6.1.4.1.18.3.4.26.3.1.15
the number of Path Failure Count error events detected in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3IntervalValidFlag 1.3.6.1.4.1.18.3.4.26.3.1.16
Indicates whether this interval reported by the Mib Table is valid or invalid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

wfDsx3TotalTable 1.3.6.1.4.1.18.3.4.26.4
The DS3/E3 Total table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDsx3TotalEntry

wfDsx3TotalEntry 1.3.6.1.4.1.18.3.4.26.4.1
per circuit DS3/E3 total objects - wfDsx3TotalIndex corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDsx3TotalEntry  

wfDsx3TotalIndex 1.3.6.1.4.1.18.3.4.26.4.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wfDsx3TotalPESs 1.3.6.1.4.1.18.3.4.26.4.1.2
the number of P-bit Errored Seconds in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3TotalPSESs 1.3.6.1.4.1.18.3.4.26.4.1.3
the number of P-bit Severely Errored Seconds in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3TotalSEFSs 1.3.6.1.4.1.18.3.4.26.4.1.4
the number of Severely Errored Framing Seconds in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3TotalUASs 1.3.6.1.4.1.18.3.4.26.4.1.5
the number of Unavailable Seconds in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3TotalLCVs 1.3.6.1.4.1.18.3.4.26.4.1.6
the number of Line Coding Violations in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3TotalPCVs 1.3.6.1.4.1.18.3.4.26.4.1.7
the number of P-bit Coding Violations in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3TotalLESs 1.3.6.1.4.1.18.3.4.26.4.1.8
the number of Line Errored Seconds in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3TotalCCVs 1.3.6.1.4.1.18.3.4.26.4.1.9
the number of C-bit Coding Violations in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3TotalCESs 1.3.6.1.4.1.18.3.4.26.4.1.10
the number of C-bit Errored Seconds in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3TotalCSESs 1.3.6.1.4.1.18.3.4.26.4.1.11
the number of C-bit Severely Errored Seconds in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3TotalSASs 1.3.6.1.4.1.18.3.4.26.4.1.12
the number of Seconds containing one or more SEFs or AIS defects in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3TotalAISSs 1.3.6.1.4.1.18.3.4.26.4.1.13
the number of Seconds containing one or more AIS defect in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3TotalFCs 1.3.6.1.4.1.18.3.4.26.4.1.14
the number of Path Failure Count error events detected in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3TotalValidFlag 1.3.6.1.4.1.18.3.4.26.4.1.15
Indicates whether this interval reported by the Mib Table is valid or invalid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

wfDsx3FarEndConfigTable 1.3.6.1.4.1.18.3.4.26.5
The DS3/E3 Far End Configuration table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDsx3FarEndConfigEntry

wfDsx3FarEndConfigEntry 1.3.6.1.4.1.18.3.4.26.5.1
per circuit DS3/E3 far end config objects - wfDsx3FarEndLineIndex corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDsx3FarEndConfigEntry  

wfDsx3FarEndLineIndex 1.3.6.1.4.1.18.3.4.26.5.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wfDsx3FarEndEquipCode 1.3.6.1.4.1.18.3.4.26.5.1.2
equipment description code - C-bit parity only
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

wfDsx3FarEndLocationIDCode 1.3.6.1.4.1.18.3.4.26.5.1.3
equipment location code - C-bit parity only
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

wfDsx3FarEndFrameIDCode 1.3.6.1.4.1.18.3.4.26.5.1.4
code for the equipment location within a building
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

wfDsx3FarEndUnitCode 1.3.6.1.4.1.18.3.4.26.5.1.5
code for the equipment location within a bay
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

wfDsx3FarEndFacilityIDCode 1.3.6.1.4.1.18.3.4.26.5.1.6
path identification code
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

wfDsx3FarEndCurrentTable 1.3.6.1.4.1.18.3.4.26.6
The DS3/E3 Far End Current table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDsx3FarEndCurrentEntry

wfDsx3FarEndCurrentEntry 1.3.6.1.4.1.18.3.4.26.6.1
per circuit DS3/E3 far end current objects wfDsx3FarEndCurrentIndex corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDsx3FarEndCurrentEntry  

wfDsx3FarEndCurrentIndex 1.3.6.1.4.1.18.3.4.26.6.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

wfDsx3FarEndTimeElapsed 1.3.6.1.4.1.18.3.4.26.6.1.2
the number of seconds since the beginning of the far end current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfDsx3FarEndValidIntervals 1.3.6.1.4.1.18.3.4.26.6.1.3
the number of previous far end intervals for which valid data is available
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfDsx3FarEndCurrentCESs 1.3.6.1.4.1.18.3.4.26.6.1.4
the number of C-bit Errored Seconds in the current far end interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndCurrentCSESs 1.3.6.1.4.1.18.3.4.26.6.1.5
the number of C-bit Severely Errored Seconds in the current far end interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndCurrentCCVs 1.3.6.1.4.1.18.3.4.26.6.1.6
the number of C-bit Coding Violations in the current far end interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndCurrentUASs 1.3.6.1.4.1.18.3.4.26.6.1.7
the number of Unavailable Seconds in the current far end interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndCurrentSASs 1.3.6.1.4.1.18.3.4.26.6.1.8
the number of Seconds containing one or more SEFs or AIS defects in the current far end interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndCurrentFCs 1.3.6.1.4.1.18.3.4.26.6.1.9
the number of Path Failure Count error events detected in the current far end interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndCurrentValidFlag 1.3.6.1.4.1.18.3.4.26.6.1.10
Indicates whether this interval reported by the Mib Table is valid or invalid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

wfDsx3FarEndIntervalTable 1.3.6.1.4.1.18.3.4.26.7
The DS3/E3 Far End Interval table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDsx3FarEndIntervalEntry

wfDsx3FarEndIntervalEntry 1.3.6.1.4.1.18.3.4.26.7.1
per circuit DS3/E3 far end interval objects - wfDsx3FarEndIntervalIndex corresponds to Wellfleet circuit number, wfDsx3FarEndIntervalNumber is the numbered previous 15-minute interval
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDsx3FarEndIntervalEntry  

wfDsx3FarEndIntervalIndex 1.3.6.1.4.1.18.3.4.26.7.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wfDsx3FarEndIntervalNumber 1.3.6.1.4.1.18.3.4.26.7.1.2
1..96 where 1 is the most recent 15-minute interval and 96 is the least
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..96  

wfDsx3FarEndIntervalCESs 1.3.6.1.4.1.18.3.4.26.7.1.3
the count of C-bit Errored Seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndIntervalCSESs 1.3.6.1.4.1.18.3.4.26.7.1.4
the count of C-bit Severely Errored Seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndIntervalCCVs 1.3.6.1.4.1.18.3.4.26.7.1.5
the count of C-bit Code Violation error events in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndIntervalUASs 1.3.6.1.4.1.18.3.4.26.7.1.6
the count of Unavailable Seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndIntervalSASs 1.3.6.1.4.1.18.3.4.26.7.1.7
the number of Seconds containing one or more SEFs or AIS defects in the specified far end interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndIntervalFCs 1.3.6.1.4.1.18.3.4.26.7.1.8
the number of Path Failure Count error events detected in the specified far end interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndIntervalValidFlag 1.3.6.1.4.1.18.3.4.26.7.1.9
Indicates whether this interval reported by the Mib Table is valid or invalid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

wfDsx3FarEndTotalTable 1.3.6.1.4.1.18.3.4.26.8
The DS3/E3 Far End Total table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDsx3FarEndTotalEntry

wfDsx3FarEndTotalEntry 1.3.6.1.4.1.18.3.4.26.8.1
per circuit far end DS3/E3 total objects - wfDsx3FarEndTotalIndex corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDsx3FarEndTotalEntry  

wfDsx3FarEndTotalIndex 1.3.6.1.4.1.18.3.4.26.8.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wfDsx3FarEndTotalCESs 1.3.6.1.4.1.18.3.4.26.8.1.2
total count of C-bit Errored Seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndTotalCSESs 1.3.6.1.4.1.18.3.4.26.8.1.3
total count of C-bit Severely Errored Seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndTotalCCVs 1.3.6.1.4.1.18.3.4.26.8.1.4
total count of C-bit Code Violation error events
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndTotalUASs 1.3.6.1.4.1.18.3.4.26.8.1.5
total count of Unavailable Seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndTotalSASs 1.3.6.1.4.1.18.3.4.26.8.1.6
the number of Seconds containing one or more SEFs or AIS defects at the far end in the last 24 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndTotalFCs 1.3.6.1.4.1.18.3.4.26.8.1.7
the number of Path Failure Count error events detected at the far end in the last 24 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndTotalValidFlag 1.3.6.1.4.1.18.3.4.26.8.1.8
Indicates whether this interval reported by the Mib Table is valid or invalid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

wfAtmInterfaceDs3PlcpTable 1.3.6.1.4.1.18.3.4.26.9
The Atm Interface DS3 PLCP table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfAtmInterfaceDs3PlcpEntry

wfAtmInterfaceDs3PlcpEntry 1.3.6.1.4.1.18.3.4.26.9.1
This table contains ATM interface DS3 PLCP parameters and state variables, one entry per ATM interface port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfAtmInterfaceDs3PlcpEntry  

wfAtmInterfaceDs3PlcpIndex 1.3.6.1.4.1.18.3.4.26.9.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wfAtmInterfaceDs3PlcpSEFSs 1.3.6.1.4.1.18.3.4.26.9.1.2
the number of DS3 PLCP Severely Errored Framing Second (SEFS)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfAtmInterfaceDs3PlcpAlarmState 1.3.6.1.4.1.18.3.4.26.9.1.3
the state of the DS3 PLCP
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noalarm(1), farendalarm(2), lof(3)  

wfAtmInterfaceDs3PlcpUASs 1.3.6.1.4.1.18.3.4.26.9.1.4
the number of Unavailable Seconds encountered by the PLCP
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayCurrentTable 1.3.6.1.4.1.18.3.4.26.11
The DS3/E3 Current table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDsx3DayCurrentEntry

wfDsx3DayCurrentEntry 1.3.6.1.4.1.18.3.4.26.11.1
per circuit DS3/E3 current objects - wfDsx3DayCurrentIndex corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDsx3DayCurrentEntry  

wfDsx3DayCurrentIndex 1.3.6.1.4.1.18.3.4.26.11.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wfDsx3DayCurrentPESs 1.3.6.1.4.1.18.3.4.26.11.1.2
the number of P-bit Errored Seconds in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayCurrentPSESs 1.3.6.1.4.1.18.3.4.26.11.1.3
the number of P-bit Severely Errored Seconds in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayCurrentSEFSs 1.3.6.1.4.1.18.3.4.26.11.1.4
the number of Severely Errored Framing Seconds in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayCurrentUASs 1.3.6.1.4.1.18.3.4.26.11.1.5
the number of Unavailable Seconds in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayCurrentLCVs 1.3.6.1.4.1.18.3.4.26.11.1.6
the number of Line Coding Violations in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayCurrentPCVs 1.3.6.1.4.1.18.3.4.26.11.1.7
the number of P-bit Coding Violations in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayCurrentLESs 1.3.6.1.4.1.18.3.4.26.11.1.8
the number of Line Errored Seconds in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayCurrentCCVs 1.3.6.1.4.1.18.3.4.26.11.1.9
the number of C-bit Coding Violations in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayCurrentCESs 1.3.6.1.4.1.18.3.4.26.11.1.10
the number of C-bit Errored Seconds in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayCurrentCSESs 1.3.6.1.4.1.18.3.4.26.11.1.11
the number of C-bit Severely Errored Seconds in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayCurrentSASs 1.3.6.1.4.1.18.3.4.26.11.1.12
the number of Seconds containing one or more SEFs or AIS defects in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayCurrentAISSs 1.3.6.1.4.1.18.3.4.26.11.1.13
the number of Seconds containing one or more AIS defect in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayCurrentFCs 1.3.6.1.4.1.18.3.4.26.11.1.14
the number of Path Failure Count error events detected in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayCurrentTimeElapsed 1.3.6.1.4.1.18.3.4.26.11.1.15
the number of seconds since the beginning of the far end current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfDsx3DayCurrentValidIntervals 1.3.6.1.4.1.18.3.4.26.11.1.16
the number of previous far end intervals for which valid data is available
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfDsx3DayCurrentValidFlag 1.3.6.1.4.1.18.3.4.26.11.1.17
Indicates whether this interval reported by the Mib Table is valid or invalid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

wfDsx3DayIntervalTable 1.3.6.1.4.1.18.3.4.26.12
The DS3/E3 Interval table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDsx3DayIntervalEntry

wfDsx3DayIntervalEntry 1.3.6.1.4.1.18.3.4.26.12.1
per circuit DS3/E3 interval objects - wfDsx3DayIntervalIndex corresponds to Wellfleet circuit number, wfDsx3DayIntervalNumber is the numbered previous 15-minute interval
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDsx3DayIntervalEntry  

wfDsx3DayIntervalIndex 1.3.6.1.4.1.18.3.4.26.12.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wfDsx3DayIntervalNumber 1.3.6.1.4.1.18.3.4.26.12.1.2
1..96 where 1 is the most recent 15-minute interval and 96 is the least
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..96  

wfDsx3DayIntervalPESs 1.3.6.1.4.1.18.3.4.26.12.1.3
the number of P-bit Errored Seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayIntervalPSESs 1.3.6.1.4.1.18.3.4.26.12.1.4
the number of P-bit Severely Errored Seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayIntervalSEFSs 1.3.6.1.4.1.18.3.4.26.12.1.5
the number of Severely Errored Framing Seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayIntervalUASs 1.3.6.1.4.1.18.3.4.26.12.1.6
the number of Unavailable Seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayIntervalLCVs 1.3.6.1.4.1.18.3.4.26.12.1.7
the number of Line Coding Violations in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayIntervalPCVs 1.3.6.1.4.1.18.3.4.26.12.1.8
the number of P-bit Coding Violations in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayIntervalLESs 1.3.6.1.4.1.18.3.4.26.12.1.9
the number of Line Errored Seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayIntervalCCVs 1.3.6.1.4.1.18.3.4.26.12.1.10
the number of C-bit Coding Violations in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayIntervalCESs 1.3.6.1.4.1.18.3.4.26.12.1.11
the number of C-bit Errored Seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayIntervalCSESs 1.3.6.1.4.1.18.3.4.26.12.1.12
the number of C-bit Severely Errored Seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayIntervalSASs 1.3.6.1.4.1.18.3.4.26.12.1.13
the number of Seconds containing one or more SEFs or AIS defects in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayIntervalAISSs 1.3.6.1.4.1.18.3.4.26.12.1.14
the number of Seconds containing one or more AIS defect in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayIntervalFCs 1.3.6.1.4.1.18.3.4.26.12.1.15
the number of Path Failure Count error events detected in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayIntervalValidFlag 1.3.6.1.4.1.18.3.4.26.12.1.16
Indicates whether this interval reported by the Mib Table is valid or invalid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

wfDsx3DayTotalTable 1.3.6.1.4.1.18.3.4.26.13
The DS3/E3 Total table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDsx3DayTotalEntry

wfDsx3DayTotalEntry 1.3.6.1.4.1.18.3.4.26.13.1
per circuit DS3/E3 total objects - wfDsx3DayTotalIndex corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDsx3DayTotalEntry  

wfDsx3DayTotalIndex 1.3.6.1.4.1.18.3.4.26.13.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wfDsx3DayTotalPESs 1.3.6.1.4.1.18.3.4.26.13.1.2
the number of P-bit Errored Seconds in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayTotalPSESs 1.3.6.1.4.1.18.3.4.26.13.1.3
the number of P-bit Severely Errored Seconds in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayTotalSEFSs 1.3.6.1.4.1.18.3.4.26.13.1.4
the number of Severely Errored Framing Seconds in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayTotalUASs 1.3.6.1.4.1.18.3.4.26.13.1.5
the number of Unavailable Seconds in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayTotalLCVs 1.3.6.1.4.1.18.3.4.26.13.1.6
the number of Line Coding Violations in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayTotalPCVs 1.3.6.1.4.1.18.3.4.26.13.1.7
the number of P-bit Coding Violations in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayTotalLESs 1.3.6.1.4.1.18.3.4.26.13.1.8
the number of Line Errored Seconds in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayTotalCCVs 1.3.6.1.4.1.18.3.4.26.13.1.9
the number of C-bit Coding Violations in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayTotalCESs 1.3.6.1.4.1.18.3.4.26.13.1.10
the number of C-bit Errored Seconds in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayTotalCSESs 1.3.6.1.4.1.18.3.4.26.13.1.11
the number of C-bit Severely Errored Seconds in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayTotalSASs 1.3.6.1.4.1.18.3.4.26.13.1.12
the number of Seconds containing one or more SEFs or AIS defects in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayTotalAISSs 1.3.6.1.4.1.18.3.4.26.13.1.13
the number of Seconds containing one or more AIS defect in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayTotalFCs 1.3.6.1.4.1.18.3.4.26.13.1.14
the number of Path Failure Count error events detected in the last 24 hours
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3DayTotalValidFlag 1.3.6.1.4.1.18.3.4.26.13.1.15
Indicates whether this interval reported by the Mib Table is valid or invalid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

wfDsx3FarEndDayCurrentTable 1.3.6.1.4.1.18.3.4.26.14
The DS3/E3 Far End Current table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDsx3FarEndDayCurrentEntry

wfDsx3FarEndDayCurrentEntry 1.3.6.1.4.1.18.3.4.26.14.1
per circuit DS3/E3 far end current objects wfDsx3FarEndDayCurrentIndex corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDsx3FarEndDayCurrentEntry  

wfDsx3FarEndDayCurrentIndex 1.3.6.1.4.1.18.3.4.26.14.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

wfDsx3FarEndDayTimeElapsed 1.3.6.1.4.1.18.3.4.26.14.1.2
the number of seconds since the beginning of the far end current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfDsx3FarEndDayValidIntervals 1.3.6.1.4.1.18.3.4.26.14.1.3
the number of previous far end intervals for which valid data is available
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfDsx3FarEndDayCurrentCESs 1.3.6.1.4.1.18.3.4.26.14.1.4
the number of C-bit Errored Seconds in the current far end interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayCurrentCSESs 1.3.6.1.4.1.18.3.4.26.14.1.5
the number of C-bit Severely Errored Seconds in the current far end interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayCurrentCCVs 1.3.6.1.4.1.18.3.4.26.14.1.6
the number of C-bit Coding Violations in the current far end interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayCurrentUASs 1.3.6.1.4.1.18.3.4.26.14.1.7
the number of Unavailable Seconds in the current far end interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayCurrentSASs 1.3.6.1.4.1.18.3.4.26.14.1.8
the number of Seconds containing one or more SEFs or AIS defects in the current far end interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayCurrentFCs 1.3.6.1.4.1.18.3.4.26.14.1.9
the number of Path Failure Count error events detected in the current far end interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayCurrentValidFlag 1.3.6.1.4.1.18.3.4.26.14.1.10
Indicates whether this interval reported by the Mib Table is valid or invalid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

wfDsx3FarEndDayIntervalTable 1.3.6.1.4.1.18.3.4.26.15
The DS3/E3 Far End Interval table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDsx3FarEndDayIntervalEntry

wfDsx3FarEndDayIntervalEntry 1.3.6.1.4.1.18.3.4.26.15.1
per circuit DS3/E3 far end interval objects - wfDsx3FarEndDayIntervalIndex corresponds to Wellfleet circuit number, wfDsx3FarEndDayIntervalNumber is the numbered previous 15-minute interval
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDsx3FarEndDayIntervalEntry  

wfDsx3FarEndDayIntervalIndex 1.3.6.1.4.1.18.3.4.26.15.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wfDsx3FarEndDayIntervalNumber 1.3.6.1.4.1.18.3.4.26.15.1.2
1..96 where 1 is the most recent 15-minute interval and 96 is the least
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..96  

wfDsx3FarEndDayIntervalCESs 1.3.6.1.4.1.18.3.4.26.15.1.3
the count of C-bit Errored Seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayIntervalCSESs 1.3.6.1.4.1.18.3.4.26.15.1.4
the count of C-bit Severely Errored Seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayIntervalCCVs 1.3.6.1.4.1.18.3.4.26.15.1.5
the count of C-bit Code Violation error events in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayIntervalUASs 1.3.6.1.4.1.18.3.4.26.15.1.6
the count of Unavailable Seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayIntervalSASs 1.3.6.1.4.1.18.3.4.26.15.1.7
the number of Seconds containing one or more SEFs or AIS defects in the specified far end interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayIntervalFCs 1.3.6.1.4.1.18.3.4.26.15.1.8
the number of Path Failure Count error events detected in the specified far end interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayIntervalValidFlag 1.3.6.1.4.1.18.3.4.26.15.1.9
Indicates whether this interval reported by the Mib Table is valid or invalid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

wfDsx3FarEndDayTotalTable 1.3.6.1.4.1.18.3.4.26.16
The DS3/E3 Far End Total table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDsx3FarEndDayTotalEntry

wfDsx3FarEndDayTotalEntry 1.3.6.1.4.1.18.3.4.26.16.1
per circuit far end DS3/E3 total objects - wfDsx3FarEndDayTotalIndex corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDsx3FarEndDayTotalEntry  

wfDsx3FarEndDayTotalIndex 1.3.6.1.4.1.18.3.4.26.16.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wfDsx3FarEndDayTotalCESs 1.3.6.1.4.1.18.3.4.26.16.1.2
total count of C-bit Errored Seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayTotalCSESs 1.3.6.1.4.1.18.3.4.26.16.1.3
total count of C-bit Severely Errored Seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayTotalCCVs 1.3.6.1.4.1.18.3.4.26.16.1.4
total count of C-bit Code Violation error events
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayTotalUASs 1.3.6.1.4.1.18.3.4.26.16.1.5
total count of Unavailable Seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayTotalSASs 1.3.6.1.4.1.18.3.4.26.16.1.6
the number of Seconds containing one or more SEFs or AIS defects at the far end in the last 24 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayTotalFCs 1.3.6.1.4.1.18.3.4.26.16.1.7
the number of Path Failure Count error events detected at the far end in the last 24 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayTotalValidFlag 1.3.6.1.4.1.18.3.4.26.16.1.8
Indicates whether this interval reported by the Mib Table is valid or invalid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

wfDsx3ThrAlrtTable 1.3.6.1.4.1.18.3.4.26.18
Current statistics Alarm Threshold Crossing table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDsx3ThrAlrtEntry

wfDsx3ThrAlrtEntry 1.3.6.1.4.1.18.3.4.26.18.1
An entry in the Dsx3 ThrAlrt table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDsx3ThrAlrtEntry  

wfDsx3ThrAlrtDelete 1.3.6.1.4.1.18.3.4.26.18.1.1
Create/Delete parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfDsx3ThrAlrtIndex 1.3.6.1.4.1.18.3.4.26.18.1.2
The instance ID that identifies the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfDsx3ThrAlrtPESs 1.3.6.1.4.1.18.3.4.26.18.1.3
The number of P-bit Errored Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3ThrAlrtPSESs 1.3.6.1.4.1.18.3.4.26.18.1.4
The number of P-bit Severely Errored Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3ThrAlrtSEFSs 1.3.6.1.4.1.18.3.4.26.18.1.5
The number of Severely Errored Framing Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3ThrAlrtUASs 1.3.6.1.4.1.18.3.4.26.18.1.6
The number of Unavailable Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3ThrAlrtLCVs 1.3.6.1.4.1.18.3.4.26.18.1.7
The number of Line Coding Violations which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3ThrAlrtPCVs 1.3.6.1.4.1.18.3.4.26.18.1.8
The number of P-bit Coding Violations which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3ThrAlrtLESs 1.3.6.1.4.1.18.3.4.26.18.1.9
The number of Line Errored Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3ThrAlrtCCVs 1.3.6.1.4.1.18.3.4.26.18.1.10
The number of C-bit Coding Violations which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3ThrAlrtCESs 1.3.6.1.4.1.18.3.4.26.18.1.11
The number of C-bit Errored Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3ThrAlrtCSESs 1.3.6.1.4.1.18.3.4.26.18.1.12
The number of C-bit Severely Errored Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3ThrAlrtSASs 1.3.6.1.4.1.18.3.4.26.18.1.13
The number of SEF/AIS Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3ThrAlrtAISSs 1.3.6.1.4.1.18.3.4.26.18.1.14
The number of AIS defect Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3ThrAlrtFCs 1.3.6.1.4.1.18.3.4.26.18.1.15
The number of Path Failure Counts which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndThrAlrtTable 1.3.6.1.4.1.18.3.4.26.19
Current Far End statistics Alarm Threshold Crossing table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDsx3FarEndThrAlrtEntry

wfDsx3FarEndThrAlrtEntry 1.3.6.1.4.1.18.3.4.26.19.1
An entry in the Dsx3 ThrAlrt table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDsx3FarEndThrAlrtEntry  

wfDsx3FarEndThrAlrtDelete 1.3.6.1.4.1.18.3.4.26.19.1.1
Create/Delete parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfDsx3FarEndThrAlrtIndex 1.3.6.1.4.1.18.3.4.26.19.1.2
The instance ID that identifies the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfDsx3FarEndThrAlrtCESs 1.3.6.1.4.1.18.3.4.26.19.1.3
The number of C-bit Errored Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndThrAlrtCSESs 1.3.6.1.4.1.18.3.4.26.19.1.4
The number of C-bit Severely Errored Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndThrAlrtCCVs 1.3.6.1.4.1.18.3.4.26.19.1.5
The number of C-bit Coding Violations which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndThrAlrtUASs 1.3.6.1.4.1.18.3.4.26.19.1.6
The number of Unavailable Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndThrAlrtSASs 1.3.6.1.4.1.18.3.4.26.19.1.7
The number of SEF/AIS Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndThrAlrtFCs 1.3.6.1.4.1.18.3.4.26.19.1.8
The number of Path Failure Counts which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3DayThrAlrtTable 1.3.6.1.4.1.18.3.4.26.20
Current Day statistics Alarm Threshold Crossing table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDsx3DayThrAlrtEntry

wfDsx3DayThrAlrtEntry 1.3.6.1.4.1.18.3.4.26.20.1
An entry in the Dsx3 ThrAlrt table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDsx3DayThrAlrtEntry  

wfDsx3DayThrAlrtDelete 1.3.6.1.4.1.18.3.4.26.20.1.1
Create/Delete parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfDsx3DayThrAlrtIndex 1.3.6.1.4.1.18.3.4.26.20.1.2
The instance ID that identifies the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfDsx3DayThrAlrtPESs 1.3.6.1.4.1.18.3.4.26.20.1.3
The number of P-bit Errored Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3DayThrAlrtPSESs 1.3.6.1.4.1.18.3.4.26.20.1.4
The number of P-bit Severely Errored Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3DayThrAlrtSEFSs 1.3.6.1.4.1.18.3.4.26.20.1.5
The number of Severely Errored Framing Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3DayThrAlrtUASs 1.3.6.1.4.1.18.3.4.26.20.1.6
The number of Unavailable Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3DayThrAlrtLCVs 1.3.6.1.4.1.18.3.4.26.20.1.7
The number of Line Coding Violations which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3DayThrAlrtPCVs 1.3.6.1.4.1.18.3.4.26.20.1.8
The number of P-bit Coding Violations which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3DayThrAlrtLESs 1.3.6.1.4.1.18.3.4.26.20.1.9
The number of Line Errored Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3DayThrAlrtCCVs 1.3.6.1.4.1.18.3.4.26.20.1.10
The number of C-bit Coding Violations which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3DayThrAlrtCESs 1.3.6.1.4.1.18.3.4.26.20.1.11
The number of C-bit Errored Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3DayThrAlrtCSESs 1.3.6.1.4.1.18.3.4.26.20.1.12
The number of C-bit Severely Errored Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3DayThrAlrtSASs 1.3.6.1.4.1.18.3.4.26.20.1.13
The number of SEF/AIS Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3DayThrAlrtAISSs 1.3.6.1.4.1.18.3.4.26.20.1.14
The number of AIS defect Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3DayThrAlrtFCs 1.3.6.1.4.1.18.3.4.26.20.1.15
The number of Path Failure Counts which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayThrAlrtTable 1.3.6.1.4.1.18.3.4.26.21
Current Far End Day statistics Alarm Threshold Crossing table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDsx3FarEndDayThrAlrtEntry

wfDsx3FarEndDayThrAlrtEntry 1.3.6.1.4.1.18.3.4.26.21.1
An entry in the Dsx3 ThrAlrt table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDsx3FarEndDayThrAlrtEntry  

wfDsx3FarEndDayThrAlrtDelete 1.3.6.1.4.1.18.3.4.26.21.1.1
Create/Delete parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfDsx3FarEndDayThrAlrtIndex 1.3.6.1.4.1.18.3.4.26.21.1.2
The instance ID that identifies the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfDsx3FarEndDayThrAlrtCESs 1.3.6.1.4.1.18.3.4.26.21.1.3
The number of C-bit Errored Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayThrAlrtCSESs 1.3.6.1.4.1.18.3.4.26.21.1.4
The number of C-bit Severely Errored Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayThrAlrtCCVs 1.3.6.1.4.1.18.3.4.26.21.1.5
The number of C-bit Coding Violations which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayThrAlrtUASs 1.3.6.1.4.1.18.3.4.26.21.1.6
The number of Unavailable Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayThrAlrtSASs 1.3.6.1.4.1.18.3.4.26.21.1.7
The number of SEF/AIS Seconds which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

wfDsx3FarEndDayThrAlrtFCs 1.3.6.1.4.1.18.3.4.26.21.1.8
The number of Path Failure Counts which must be received prior to the generation of a Threshold Crossing Alert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge