Wellfleet-DS3-MIB

File: Wellfleet-DS3-MIB.mib (21137 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC-1215
RFC1213-MIB Wellfleet-COMMON-MIB

Imported symbols

IpAddress Counter Gauge
TimeTicks Opaque enterprises
mgmt OBJECT-TYPE TRAP-TYPE
DisplayString mib-2 wfDs3Group

Defined Types

WfDs3ConfigEntry  
SEQUENCE    
  wfDs3LineIndex INTEGER
  wfDs3TimeElapsed INTEGER
  wfDs3ValidIntervals INTEGER
  wfDs3LineType INTEGER
  wfDs3ZeroCoding INTEGER
  wfDs3SendCode INTEGER
  wfDs3CircuitIdentifier DisplayString
  wfDs3LoopbackConfig INTEGER
  wfDs3LineStatus INTEGER

WfDs3CurrentEntry  
SEQUENCE    
  wfDs3CurrentIndex INTEGER
  wfDs3CurrentESs Counter
  wfDs3CurrentSESs Counter
  wfDs3CurrentSEFs Counter
  wfDs3CurrentUASs Counter
  wfDs3CurrentBPVs Counter
  wfDs3CurrentCVs Counter

WfDs3IntervalEntry  
SEQUENCE    
  wfDs3IntervalIndex INTEGER
  wfDs3IntervalNumber INTEGER
  wfDs3IntervalESs Gauge
  wfDs3IntervalSESs Gauge
  wfDs3IntervalSEFs Gauge
  wfDs3IntervalUASs Gauge
  wfDs3IntervalBPVs Gauge
  wfDs3IntervalCVs Gauge

WfDs3TotalEntry  
SEQUENCE    
  wfDs3TotalIndex INTEGER
  wfDs3TotalESs Gauge
  wfDs3TotalSESs Gauge
  wfDs3TotalSEFs Gauge
  wfDs3TotalUASs Gauge
  wfDs3TotalBPVs Gauge
  wfDs3TotalCVs Gauge

WfDs3FeConfigEntry  
SEQUENCE    
  wfDs3FeConfigIndex INTEGER
  wfDs3FarEndEquipCode DisplayString
  wfDs3FarEndLocationIDCode DisplayString
  wfDs3FarEndFrameIDCode DisplayString
  wfDs3FarEndUnitCode DisplayString
  wfDs3FarEndFacilityIDCode DisplayString

WfDs3FeCurrentEntry  
SEQUENCE    
  wfDs3FeCurrentIndex INTEGER
  wfDs3FeCurrentESs Counter
  wfDs3FeCurrentSESs Counter
  wfDs3FeCurrentCVs Counter

WfDs3FeIntervalEntry  
SEQUENCE    
  wfDs3FeIntervalIndex INTEGER
  wfDs3FeIntervalNumber INTEGER
  wfDs3FeIntervalESs Gauge
  wfDs3FeIntervalSESs Gauge
  wfDs3FeIntervalCVs Gauge

WfDs3FeTotalEntry  
SEQUENCE    
  wfDs3FeTotalIndex INTEGER
  wfDs3FeTotalESs Gauge
  wfDs3FeTotalSESs Gauge
  wfDs3FeTotalCVs Gauge

Defined Values

wfDs3Config 1.3.6.1.4.1.18.3.4.13.1
The DS3 Configuration table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDs3ConfigEntry

wfDs3ConfigEntry 1.3.6.1.4.1.18.3.4.13.1.1
per circuit DS3 configuration objects; wfDs3LineIndex corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDs3ConfigEntry  

wfDs3LineIndex 1.3.6.1.4.1.18.3.4.13.1.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

wfDs3TimeElapsed 1.3.6.1.4.1.18.3.4.13.1.1.2
1..900 seconds within the current 15-minute interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfDs3ValidIntervals 1.3.6.1.4.1.18.3.4.13.1.1.3
0..96 previous intervals that valid data were collected. This is 96 unless the CSU device was brought on line within the last 24 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

wfDs3LineType 1.3.6.1.4.1.18.3.4.13.1.1.4
the variety of DS3 implementing this circuit
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ds3cbitparity(4), ds3clearchannel(5)  

wfDs3ZeroCoding 1.3.6.1.4.1.18.3.4.13.1.1.5
the variety of Zero Code Suppression used on the link
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ds3b3zs(2)  

wfDs3SendCode 1.3.6.1.4.1.18.3.4.13.1.1.6
the type of code being sent across the DS3 circuit by the CSU
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ds3sendnocode(2)  

wfDs3CircuitIdentifier 1.3.6.1.4.1.18.3.4.13.1.1.7
the transmission vendor's circuit identifier
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

wfDs3LoopbackConfig 1.3.6.1.4.1.18.3.4.13.1.1.8
the loopback state of the CSU
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ds3noloop(1), ds3mgrpayloadloop(2), ds3mgrlineloop(3), ds3netreqpayloadloop(4), ds3netreqlineloop(5), ds3otherloop(6)  

wfDs3LineStatus 1.3.6.1.4.1.18.3.4.13.1.1.9
the state of the DS3 line
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ds3noalarm(1), ds3farendalarm(2), ds3alarmindicationsignal(4), ds3lossofframe(8), ds3lossofsignal(16), ds3loopbackstate(32)  

wfDs3Current 1.3.6.1.4.1.18.3.4.13.2
The DS3 Current table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDs3CurrentEntry

wfDs3CurrentEntry 1.3.6.1.4.1.18.3.4.13.2.1
per circuit DS3 current objects - wfDs3CurrentIndex corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDs3CurrentEntry  

wfDs3CurrentIndex 1.3.6.1.4.1.18.3.4.13.2.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

wfDs3CurrentESs 1.3.6.1.4.1.18.3.4.13.2.1.2
the count of errored seconds in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfDs3CurrentSESs 1.3.6.1.4.1.18.3.4.13.2.1.3
the count of severely errored seconds in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfDs3CurrentSEFs 1.3.6.1.4.1.18.3.4.13.2.1.4
the count of severely errored framing seconds in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfDs3CurrentUASs 1.3.6.1.4.1.18.3.4.13.2.1.5
the number of unavailable seconds in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfDs3CurrentBPVs 1.3.6.1.4.1.18.3.4.13.2.1.6
the count of bipolar violations in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfDs3CurrentCVs 1.3.6.1.4.1.18.3.4.13.2.1.7
the count of code violation error events in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfDs3Interval 1.3.6.1.4.1.18.3.4.13.3
The DS3 Interval table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDs3IntervalEntry

wfDs3IntervalEntry 1.3.6.1.4.1.18.3.4.13.3.1
per circuit DS3 interval objects - wfDs3IntervalIndex corresponds to Wellfleet circuit number, wfDs3IntervalNumber is the numbered previous 15-minute interval
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDs3IntervalEntry  

wfDs3IntervalIndex 1.3.6.1.4.1.18.3.4.13.3.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

wfDs3IntervalNumber 1.3.6.1.4.1.18.3.4.13.3.1.2
1..96 where 1 is the most recent 15-minute interval and 96 is the least
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..96  

wfDs3IntervalESs 1.3.6.1.4.1.18.3.4.13.3.1.3
the count of errored seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDs3IntervalSESs 1.3.6.1.4.1.18.3.4.13.3.1.4
the count of severely errored seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDs3IntervalSEFs 1.3.6.1.4.1.18.3.4.13.3.1.5
the count of severely errored framing seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDs3IntervalUASs 1.3.6.1.4.1.18.3.4.13.3.1.6
the number of unavailable seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDs3IntervalBPVs 1.3.6.1.4.1.18.3.4.13.3.1.7
the count of bipolar violations in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDs3IntervalCVs 1.3.6.1.4.1.18.3.4.13.3.1.8
the count of code violation error events in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDs3Total 1.3.6.1.4.1.18.3.4.13.4
The DS3 Total table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDs3TotalEntry

wfDs3TotalEntry 1.3.6.1.4.1.18.3.4.13.4.1
per circuit DS3 total objects - wfDs3TotalIndex corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDs3TotalEntry  

wfDs3TotalIndex 1.3.6.1.4.1.18.3.4.13.4.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

wfDs3TotalESs 1.3.6.1.4.1.18.3.4.13.4.1.2
total count of errored seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDs3TotalSESs 1.3.6.1.4.1.18.3.4.13.4.1.3
total count of severely errored seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDs3TotalSEFs 1.3.6.1.4.1.18.3.4.13.4.1.4
total count of severely errored framing seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDs3TotalUASs 1.3.6.1.4.1.18.3.4.13.4.1.5
total number of unavailable seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDs3TotalBPVs 1.3.6.1.4.1.18.3.4.13.4.1.6
total count of bipolar violations
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDs3TotalCVs 1.3.6.1.4.1.18.3.4.13.4.1.7
total count of code violation error events
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDs3FeConfig 1.3.6.1.4.1.18.3.4.13.5
The DS3 Far End Configuration table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDs3FeConfigEntry

wfDs3FeConfigEntry 1.3.6.1.4.1.18.3.4.13.5.1
per circuit DS3 far end config objects - wfDs3FeIntervalIndex corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDs3FeConfigEntry  

wfDs3FeConfigIndex 1.3.6.1.4.1.18.3.4.13.5.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

wfDs3FarEndEquipCode 1.3.6.1.4.1.18.3.4.13.5.1.2
equipment description code - C-bit parity only
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

wfDs3FarEndLocationIDCode 1.3.6.1.4.1.18.3.4.13.5.1.3
equipment location code - C-bit parity only
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

wfDs3FarEndFrameIDCode 1.3.6.1.4.1.18.3.4.13.5.1.4
code for the equipment location within a building
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

wfDs3FarEndUnitCode 1.3.6.1.4.1.18.3.4.13.5.1.5
code for the equipment location within a bay
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

wfDs3FarEndFacilityIDCode 1.3.6.1.4.1.18.3.4.13.5.1.6
path identification code
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

wfDs3FeCurrent 1.3.6.1.4.1.18.3.4.13.6
The DS3 Far End Current table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDs3FeCurrentEntry

wfDs3FeCurrentEntry 1.3.6.1.4.1.18.3.4.13.6.1
per circuit DS3 far end current objects wfDs3FeCurrentIndex corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDs3FeCurrentEntry  

wfDs3FeCurrentIndex 1.3.6.1.4.1.18.3.4.13.6.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

wfDs3FeCurrentESs 1.3.6.1.4.1.18.3.4.13.6.1.2
the count of errored seconds in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfDs3FeCurrentSESs 1.3.6.1.4.1.18.3.4.13.6.1.3
the count of severely errored seconds in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfDs3FeCurrentCVs 1.3.6.1.4.1.18.3.4.13.6.1.4
the count of code violation error events in the current interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfDs3FeInterval 1.3.6.1.4.1.18.3.4.13.7
The DS3 Far End Interval table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDs3FeIntervalEntry

wfDs3FeIntervalEntry 1.3.6.1.4.1.18.3.4.13.7.1
per circuit DS3 far end interval objects - wfDs3FeIntervalIndex corresponds to Wellfleet circuit number, wfDs3FeIntervalNumber is the numbered previous 15-minute interval
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDs3FeIntervalEntry  

wfDs3FeIntervalIndex 1.3.6.1.4.1.18.3.4.13.7.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

wfDs3FeIntervalNumber 1.3.6.1.4.1.18.3.4.13.7.1.2
1..96 where 1 is the most recent 15-minute interval and 96 is the least
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..96  

wfDs3FeIntervalESs 1.3.6.1.4.1.18.3.4.13.7.1.3
the count of errored seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDs3FeIntervalSESs 1.3.6.1.4.1.18.3.4.13.7.1.4
the count of severely errored seconds in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDs3FeIntervalCVs 1.3.6.1.4.1.18.3.4.13.7.1.5
the count of code violation error events in the specified interval
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDs3FeTotal 1.3.6.1.4.1.18.3.4.13.8
The DS3 Far End Total table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfDs3FeTotalEntry

wfDs3FeTotalEntry 1.3.6.1.4.1.18.3.4.13.8.1
per circuit far end DS3 total objects - wfDs3FeTotalIndex corresponds to Wellfleet circuit number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfDs3FeTotalEntry  

wfDs3FeTotalIndex 1.3.6.1.4.1.18.3.4.13.8.1.1
this corresponds to the Wellfleet circuit number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

wfDs3FeTotalESs 1.3.6.1.4.1.18.3.4.13.8.1.2
total count of errored seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDs3FeTotalSESs 1.3.6.1.4.1.18.3.4.13.8.1.3
total count of severely errored seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

wfDs3FeTotalCVs 1.3.6.1.4.1.18.3.4.13.8.1.4
total count of code violation error events
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge