WWP-LEOS-PORT-XCVR-MIB

File: WWP-LEOS-PORT-XCVR-MIB.mib (46636 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC WWP-SMI

Imported symbols

Integer32 Unsigned32 OBJECT-TYPE
NOTIFICATION-TYPE MODULE-IDENTITY DisplayString
TruthValue wwpModules wwpModulesLeos

Defined Types

WwpLeosPortXcvrEntry  
SEQUENCE    
  wwpLeosPortXcvrId INTEGER
  wwpLeosPortXcvrOperState INTEGER
  wwpLeosPortXcvrIdentiferType INTEGER
  wwpLeosPortXcvrExtIdentiferType INTEGER
  wwpLeosPortXcvrConnectorType INTEGER
  wwpLeosPortXcvrType INTEGER
  wwpLeosPortXcvrVendorName DisplayString
  wwpLeosPortXcvrVendorOUI OCTET STRING
  wwpLeosPortXcvrVendorPN DisplayString
  wwpLeosPortXcvrRevNum DisplayString
  wwpLeosPortXcvrSerialNum DisplayString
  wwpLeosPortXcvrEncodingType INTEGER
  wwpLeosPortXcvrMfgDate DisplayString
  wwpLeosPortXcvrComplianceVer INTEGER
  wwpLeosPortXcvrWaveLength INTEGER
  wwpLeosPortXcvrTemperature INTEGER
  wwpLeosPortXcvrVcc INTEGER
  wwpLeosPortXcvrBias INTEGER
  wwpLeosPortXcvrRxPower INTEGER
  wwpLeosPortXcvrTxState INTEGER
  wwpLeosPortXcvrTxFaultStatus INTEGER
  wwpLeosPortXcvrRxRateStatus INTEGER
  wwpLeosPortXcvr9by125um INTEGER
  wwpLeosPortXcvr50by125um INTEGER
  wwpLeosPortXcvr62dot5by125um INTEGER
  wwpLeosPortXcvrCu INTEGER
  wwpLeosPortXcvrTxOutputPw INTEGER
  wwpLeosPortXcvrLosState TruthValue
  wwpLeosPortXcvrDiagSupported TruthValue
  wwpLeosPortXcvrEnhDiagAlarmSupported TruthValue
  wwpLeosPortXcvrEnhDiagSoftTxDisableSupported TruthValue
  wwpLeosPortXcvrEnhDiagSoftTxFaultSupported TruthValue
  wwpLeosPortXcvrEnhDiagRxLosSupported TruthValue
  wwpLeosPortXcvrHighTempAlarmThreshold Integer32
  wwpLeosPortXcvrLowTempAlarmThreshold Integer32
  wwpLeosPortXcvrHighVccAlarmThreshold Integer32
  wwpLeosPortXcvrLowVccAlarmThreshold Integer32
  wwpLeosPortXcvrHighBiasAlarmThreshold Integer32
  wwpLeosPortXcvrLowBiasAlarmThreshold Integer32
  wwpLeosPortXcvrHighTxPwAlarmThreshold Integer32
  wwpLeosPortXcvrLowTxPwAlarmThreshold Integer32
  wwpLeosPortXcvrHighRxPwAlarmThreshold Integer32
  wwpLeosPortXcvrLowRxPwAlarmThreshold Integer32
  wwpLeosPortXcvrLowRxPwAlarmThreshold Integer32
  wwpLeosPortXcvrLowRxPwAlarmThreshold Integer32
  wwpLeosPortXcvrEnhDiagRateSelectSupported TruthValue
  wwpLeosPortXcvrAdminState INTEGER
  wwpLeosPortXcvrXfpMinBitRate INTEGER
  wwpLeosPortXcvrXfpMaxBitRate INTEGER
  wwpLeosPortXcvrXfpLinkLenSmf1km INTEGER
  wwpLeosPortXcvrXfpLinkLenE50u2m INTEGER
  wwpLeosPortXcvrXfpLinkLen50u1m INTEGER
  wwpLeosPortXcvrXfpLinkLen62dot5u1m INTEGER
  wwpLeosPortXcvrXfpLinkLenCopper1m INTEGER
  wwpLeosPortXcvrXfpDevTech INTEGER
  wwpLeosPortXcvrXfpTransmitterTech INTEGER
  wwpLeosPortXcvrXfpCdrSupport INTEGER
  wwpLeosPortXcvrXfpWaveLengthTol INTEGER
  wwpLeosPortXcvrXfpMaxCaseTemp INTEGER
  wwpLeosPortXcvrXfpMaxPower INTEGER
  wwpLeosPortXcvrXfpMax5vCurrent INTEGER
  wwpLeosPortXcvrXfpMax3p3vCurrent INTEGER
  wwpLeosPortXcvrXfpMax1p8vCurrent INTEGER
  wwpLeosPortXcvrXfpMaxNeg5p2vCurrent INTEGER
  wwpLeosPortXcvrXfpDiagMonitorType INTEGER
  wwpLeosPortXcvrXfpEnhancedOptions INTEGER
  wwpLeosPortXcvrXfpAuxMonitoringInput1 INTEGER
  wwpLeosPortXcvrXfpAuxMonitoringInput2 INTEGER
  wwpLeosPortXcvrAdminFrequency Unsigned32
  wwpLeosPortXcvrXfpLaserFirstFrequency Unsigned32
  wwpLeosPortXcvrXfpLaserLastFrquency Unsigned32
  wwpLeosPortXcvrXfpMaxGridScacing INTEGER
  wwpLeosPortXcvrXfpChannelNum INTEGER
  wwpLeosPortXcvrXfpFrequencyError INTEGER
  wwpLeosPortXcvrAdminWavelength Unsigned32
  wwpLeosPortXcvrAdminChannel Unsigned32
  wwpLeosPortXcvrXfpLaserFirstWavelenth Unsigned32
  wwpLeosPortXcvrXfpLaserLastWavelength Unsigned32
  wwpLeosPortXcvrXfpLaserFirstChannel Unsigned32
  wwpLeosPortXcvrXfpLaserLastChannel Unsigned32
  wwpLeosPortXcvrOperFrequency Unsigned32
  wwpLeosPortXcvrOperWavelength Unsigned32
  wwpLeosPortXcvrRxDbmPower Integer32
  wwpLeosPortXcvrTxDbmPower Integer32
  wwpLeosPortXcvrHighTxDbmPwAlarmThreshold Integer32
  wwpLeosPortXcvrLowTxDbmPwAlarmThreshold Integer32
  wwpLeosPortXcvrHighRxDbmPwAlarmThreshold Integer32
  wwpLeosPortXcvrLowRxDbmPwAlarmThreshold Integer32

Defined Values

wwpLeosPortXcvrMIB 1.3.6.1.4.1.6141.2.60.4
Corrected Units changed watts to uW in descriptions.
MODULE-IDENTITY    

wwpLeosPortXcvrMIBObjects 1.3.6.1.4.1.6141.2.60.4.1
OBJECT IDENTIFIER    

wwpLeosPortXcvr 1.3.6.1.4.1.6141.2.60.4.1.1
OBJECT IDENTIFIER    

wwpLeosPortXcvrNotif 1.3.6.1.4.1.6141.2.60.4.1.2
OBJECT IDENTIFIER    

wwpLeosPortXcvrMIBNotificationPrefix 1.3.6.1.4.1.6141.2.60.4.2
OBJECT IDENTIFIER    

wwpLeosPortXcvrMIBNotifications 1.3.6.1.4.1.6141.2.60.4.2.0
OBJECT IDENTIFIER    

wwpLeosPortXcvrMIBConformance 1.3.6.1.4.1.6141.2.60.4.3
OBJECT IDENTIFIER    

wwpLeosPortXcvrMIBCompliances 1.3.6.1.4.1.6141.2.60.4.3.1
OBJECT IDENTIFIER    

wwpLeosPortXcvrMIBGroups 1.3.6.1.4.1.6141.2.60.4.3.2
OBJECT IDENTIFIER    

wwpLeosPortXcvrTable 1.3.6.1.4.1.6141.2.60.4.1.1.1
This table contains descriptions and settings for each of the physical transceiver devices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WwpLeosPortXcvrEntry

wwpLeosPortXcvrEntry 1.3.6.1.4.1.6141.2.60.4.1.1.1.1
The Transciever Device Entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  WwpLeosPortXcvrEntry  

wwpLeosPortXcvrId 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.1
The ID for the transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrOperState 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.2
The operational state of the transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), loopback(3), notPresent(4), faulted(5)  

wwpLeosPortXcvrIdentiferType 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.3
Type for the transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), gbic(2), solderedType(3), sfp(4), reserved(5), vendorSpecific(6), xbi(7), xenpak(8), xfp(9), xff(10), xfpe(11), xpak(12), x2(13)  

wwpLeosPortXcvrExtIdentiferType 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.4
Extended identifier type for this transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), sfp-gbic(2)  

wwpLeosPortXcvrConnectorType 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.5
Type of connector. unknown(1), sc(2), fiberChannelStyle1(3), fiberChannelStyle2(4), bnc/tnc(5), coaxialHeader(6), fiberJack(7), lc(8), mt-rj(9), mu(10), sg(11), opticalPitTail(12), reserved(13..32), hssdc(33), copperPitTail(34), reserved(35..128), vendorSpecific(129..256).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrType 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.6
Type of Transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrVendorName 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.7
String containing this transceiver's vendor name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

wwpLeosPortXcvrVendorOUI 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.8
String containing this transceiver's vendor OUI.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

wwpLeosPortXcvrVendorPN 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.9
String containing this transceiver's vendor OUI.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

wwpLeosPortXcvrRevNum 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.10
String containing this transceiver's part revision number.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

wwpLeosPortXcvrSerialNum 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.11
String containing this transceiver's part serial number.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

wwpLeosPortXcvrEncodingType 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.12
If wwpLeosPortXcvrIdentiferType is SFP, then the following values is defined for the encoding type: unspecified(1), 8B10B(2), 4b5b(3), NRZ(4), Manchester(5), SONET(6), reserved(7-256) If wwpLeosPortXcvrIdentiferType is XFP, then the following values is defined for the encoding type: Bit 7: 64B/66B (yes/no) Bit 6: 8B10B (yes/no) Bit 5: Sonet Scrambled (yes/no) Bit 4: NRZ (yes/no) Bit 3: RZ (yes/no) Bit 2: Tx Dither Support (yes/no) Bit 1: Reserved Bit 0: Reserved Multiple bits can be set at once in the case of XFP. For instance, to indicate support for NRZ(4) and Sonet scrambled (5), the user would see this object with the value of 16 + 32 = 48
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrMfgDate 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.13
The transceiver's manufacture date in string.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

wwpLeosPortXcvrComplianceVer 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.14
This represents the compliance version. Value 1 means digital diagnostic functionality not included or undefined Value 2 means includes functionality defined in Rev 9.0 SFF-8472 Value 3 means TBD Value 4 means TBD.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

wwpLeosPortXcvrWaveLength 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.15
This represents the wavelength of the transceiver. Units are nano meter.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrTemperature 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.16
This represents the temperature of the transceiver. Units are in degrees C
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrVcc 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.17
This represents the voltage of the transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrBias 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.18
This represents the bias of the transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrRxPower 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.19
This represents the measured receive power of the transceiver. Units are micro Watts.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrTxState 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.20
Indicates whether this transceiver is currently set to transmit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wwpLeosPortXcvrTxFaultStatus 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.21
Indicates the fault status of this transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER fault(1), noFault(2)  

wwpLeosPortXcvrRxRateStatus 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.22
Indicates the Rx rate status of this transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wwpLeosPortXcvr9by125um 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.23
Indicates the link length for 9/125um fiber.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvr50by125um 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.24
Indicates the link length for 50/125um fiber.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvr62dot5by125um 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.25
Indicates the link length for 62.5/125um fiber.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrCu 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.26
Indicates the link length for copper.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrTxOutputPw 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.27
Indicates the Tx Output power for the transceiver. Units are micro Watts.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrLosState 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.28
Indicates the Loss Of Signal State for the optical transceiver. Ports without optical transceiver will always report 'false'.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

wwpLeosPortXcvrDiagSupported 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.29
Indicates if diagnostics are supported on this transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

wwpLeosPortXcvrEnhDiagAlarmSupported 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.30
Indicates if enhanced diagnostics alarms / warnings implemented.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

wwpLeosPortXcvrEnhDiagSoftTxDisableSupported 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.31
Indicates if enhanced diagnostics soft Tx disable control is implemented.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

wwpLeosPortXcvrEnhDiagSoftTxFaultSupported 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.32
Indicates if enhanced diagnostics soft Tx fault monitoring is implemented.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

wwpLeosPortXcvrEnhDiagRxLosSupported 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.33
Indicates if enhanced diagnostics Rx LOS monitoring is implemented.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

wwpLeosPortXcvrHighTempAlarmThreshold 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.34
Indicates the higher threshold for temperature alarm.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wwpLeosPortXcvrLowTempAlarmThreshold 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.35
Indicates the lower threshold for temperature alarm.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wwpLeosPortXcvrHighVccAlarmThreshold 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.36
Indicates the higher threshold for voltage alarm.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wwpLeosPortXcvrLowVccAlarmThreshold 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.37
Indicates the lower threshold for voltage alarm.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wwpLeosPortXcvrHighBiasAlarmThreshold 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.38
Indicates the higher threshold for bias alarm.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wwpLeosPortXcvrLowBiasAlarmThreshold 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.39
Indicates the lower threshold for bias alarm.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wwpLeosPortXcvrHighTxPwAlarmThreshold 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.40
Indicates the higher threshold for Tx power alarm. Units are micro watts
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wwpLeosPortXcvrLowTxPwAlarmThreshold 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.41
Indicates the lower threshold for Tx power alarm. Units are micro watts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wwpLeosPortXcvrHighRxPwAlarmThreshold 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.42
Indicates the higher threshold for Rx power alarm. Units are micro watts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wwpLeosPortXcvrLowRxPwAlarmThreshold 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.43
Indicates the lower threshold for Rx power alarm. Units are micro watts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wwpLeosPortXcvrEnhDiagRateSelectSupported 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.44
Indicates if enhanced diagnostics soft rate select control is implemented.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

wwpLeosPortXcvrAdminState 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.45
The admin state of the transceiver.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), loopback(3)  

wwpLeosPortXcvrXfpMinBitRate 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.70
This represents the minimum bit rate.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrXfpMaxBitRate 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.71
This represents the maximum bit rate.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrXfpLinkLenSmf1km 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.72
This represents the length (SMF fiber) 1km.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrXfpLinkLenE50u2m 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.73
This represents the length (ext. BW MMF) 2m.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrXfpLinkLen50u1m 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.74
This represents the length (50um) 1m.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrXfpLinkLen62dot5u1m 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.75
This represents the length (62.5um) 1m.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrXfpLinkLenCopper1m 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.76
This represents the length (copper) 1m.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrXfpDevTech 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.77
This represents the device technology.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER vcsel850nm(1), vcsel1310nm(2), vcsel1550nm(3), fp1310nm(4), dfb1310nm(5), dfb1550nm(6), eml1310nm(7), eml1550nm(8), copperOrOther(9), tunable1550nm(10), reserved(11)  

wwpLeosPortXcvrXfpTransmitterTech 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.78
This represents the device transmitter technology: Bit 3: Wavelength Control (active/none) Bit 2: Transmitter Cooling (cooled/uncooled) Bit 1: Detector Type (apd/pin) Bit 0: Transmitter Tuning (Tunable/non-Tunable)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrXfpCdrSupport 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.79
This represents the CDR support: Bit 7: 9.95 Gb/s (yes/no) Bit 6: 10.3 Gb/s (yes/no) Bit 5: 10.5 Gb/s (yes/no) Bit 4: 10.7 Gb/s (yes/no) Bit 3: 11.1 Gb/s (yes/no) Bit 2: N/A Bit 1: Lineside Loopback (yes/no) Bit 0: XFI Loopback (yes/no)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrXfpWaveLengthTol 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.80
This represents the wavelength tolerance.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrXfpMaxCaseTemp 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.81
This represents the maximum case temperature.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrXfpMaxPower 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.82
This represents the maximum power dissipation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrXfpMax5vCurrent 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.83
This represents the 5.0 Volt Max Current.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrXfpMax3p3vCurrent 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.84
This represents the 3.3 Volt Max Current.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrXfpMax1p8vCurrent 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.85
This represents the 1.8 Volt Max Current.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrXfpMaxNeg5p2vCurrent 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.86
This represents the -5.2 Volt Max Current.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrXfpDiagMonitorType 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.87
This represents the diag monitor type: Bit 4 indicates BER support. Bit 3 indidates the Rx Power Meas. type of Avg or OMA.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrXfpEnhancedOptions 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.88
This represents the enhanced options: Bit 7: VPS Support (yes/no) Bit 6: Soft TX_DISABLE (yes/no) Bit 5: Soft P_down (yes/no) Bit 4: VPS LV Regulator Mode (yes/no) Bit 3: VPS bypassed Reg. Mode (yes/no) Bit 2: Active FEC Ctrl (yes/no) Bit 1: Wavelength or frequency Tunability (yes/no) Bit 0: CMU Support Mode (yes/no)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrXfpAuxMonitoringInput1 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.89
This represents the Aux monitoring of A/D input 1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), aPDBiasVoltage(2), reserved(3), tECCurrentMa(4), laserTemp(5), laserWavelength(6), voltage5V(7), voltage3p3V(8), voltage1p8V(9), voltageNeg5p2V(10), voltage5VCurrent(11), voltage3p3VCurrent(12), voltage1p8VCurrent(13), voltageNeg5p2VCurrent(14), unknown(15)  

wwpLeosPortXcvrXfpAuxMonitoringInput2 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.90
This represents the Aux monitoring of A/D input 2.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), aPDBiasVoltage(2), reserved(3), tECCurrentMa(4), laserTemp(5), laserWavelength(6), voltage5V(7), voltage3p3V(8), voltage1p8V(9), voltageNeg5p2V(10), voltage5VCurrent(11), voltage3p3VCurrent(12), voltage1p8VCurrent(13), voltageNeg5p2VCurrent(14), unknown(15)  

wwpLeosPortXcvrAdminFrequency 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.91
The admin frequency of the transceiver in GHz
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..4294967295  

wwpLeosPortXcvrXfpLaserFirstFrequency 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.92
This represents the first frequency in GHz
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

wwpLeosPortXcvrXfpLaserLastFrquency 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.93
This represents the last frequency in GHz
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

wwpLeosPortXcvrXfpMaxGridScacing 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.94
This represents the maximun support grid spacing in GHz
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

wwpLeosPortXcvrXfpChannelNum 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.95
This represents the channel number
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

wwpLeosPortXcvrXfpFrequencyError 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.96
This represents the frequency error
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -32768..32767  

wwpLeosPortXcvrAdminWavelength 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.97
The admin wavelength of the transceiver in pico-meter
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

wwpLeosPortXcvrAdminChannel 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.98
The admin channel number of the transceiver
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

wwpLeosPortXcvrXfpLaserFirstWavelenth 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.99
This represents the first wavelength in pico meter
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

wwpLeosPortXcvrXfpLaserLastWavelength 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.100
This represents the last wavelength in pico meter
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

wwpLeosPortXcvrXfpLaserFirstChannel 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.101
This represents the first channel number
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

wwpLeosPortXcvrXfpLaserLastChannel 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.102
This represents the last channel number
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

wwpLeosPortXcvrOperFrequency 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.103
The operational frequency of the transceiver in GHz
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

wwpLeosPortXcvrOperWavelength 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.104
The operational wavelength of the transceiver in pico-meter
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

wwpLeosPortXcvrRxDbmPower 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.105
Indicates the Rx power level in dBm after scaling and conversion to an integer. To convert back to dBm, convert this value to floating point and divide by 10,000.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wwpLeosPortXcvrTxDbmPower 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.106
Indicates the Tx power level in dBm after scaling and conversion to an integer. To convert back to dBm, convert this value to floating point and divide by 10,000.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wwpLeosPortXcvrHighTxDbmPwAlarmThreshold 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.107
Indicates the higher threshold for Tx power alarm in dBm after scaling and conversion to an integer. To convert back to dBm, convert this value to floating point and divide by 10,000.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wwpLeosPortXcvrLowTxDbmPwAlarmThreshold 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.108
Indicates the lower threshold for Tx power alarm in dBm after scaling and conversion to an integer. To convert back to dBm, convert this value to floating point and divide by 10,000.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wwpLeosPortXcvrHighRxDbmPwAlarmThreshold 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.109
Indicates the higher threshold for Rx power alarm in dBm after scaling and conversion to an integer. To convert back to dBm, convert this value to floating point and divide by 10,000.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wwpLeosPortXcvrLowRxDbmPwAlarmThreshold 1.3.6.1.4.1.6141.2.60.4.1.1.1.1.110
Indicates the lower threshold for Rx power alarm in dBm after scaling and conversion to an integer. To convert back to dBm, convert this value to floating point and divide by 10,000.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wwpLeosPortXcvrEventType 1.3.6.1.4.1.6141.2.60.4.1.2.1
Indicates if the Xcvr specified by the wwpLeosPortXcvrId has come up, gone down or has been selected.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inserted(1), removed(2), enabled(3), disabled(4)  

wwpLeosPortXcvrErrorType 1.3.6.1.4.1.6141.2.60.4.1.2.2
Indicates if the Xcvr specified by the wwpLeosPortXcvrId is faulted because of checksum failure or optical fault. This object only makes sense if transceiver has been detected faulted otherwise it returns none.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), chksumFailed(1), opticalFault(2)  

wwpLeosPortXcvrLinkStateChangeNotification 1.3.6.1.4.1.6141.2.60.4.2.0.4
A wwpLeosPortXcvrLinkStateChangeNotification is sent if the Xcvr state has changed.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrErrorTypeNotification 1.3.6.1.4.1.6141.2.60.4.2.0.5
A wwpLeosPortXcvrErrorTypeNotification is sent if the Xcvr is detected faulted because of some reason. Reason of failure is specified by wwpLeosPortXcvrErrorType.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrTempHighNotification 1.3.6.1.4.1.6141.2.60.4.2.0.6
A wwpLeosPortXcvrTempHighNotification is sent if the Xcvr temperature exceeds the threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrTempLowNotification 1.3.6.1.4.1.6141.2.60.4.2.0.7
A wwpLeosPortXcvrTempLowNotification is sent if the Xcvr temperature decreases the threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrTempNormalNotification 1.3.6.1.4.1.6141.2.60.4.2.0.8
A wwpLeosPortXcvrTempNormalNotification is sent if the Xcvr temperature returns back to normal state.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrVoltageHighNotification 1.3.6.1.4.1.6141.2.60.4.2.0.9
A wwpLeosPortXcvrVoltageHighNotification is sent if the Xcvr voltage exceeds the threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrVoltageLowNotification 1.3.6.1.4.1.6141.2.60.4.2.0.10
A wwpLeosPortXcvrVoltageLowNotification is sent if the Xcvr voltage decreases the threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrVoltageNormalNotification 1.3.6.1.4.1.6141.2.60.4.2.0.11
A wwpLeosPortXcvrVoltageNormalNotification is sent if the Xcvr voltage returns back to normal state.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrBiasHighNotification 1.3.6.1.4.1.6141.2.60.4.2.0.12
A wwpLeosPortXcvrBiasHighNotification is sent if the Xcvr Bias exceeds the threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrBiasLowNotification 1.3.6.1.4.1.6141.2.60.4.2.0.13
A wwpLeosPortXcvrBiasLowNotification is sent if the Xcvr voltage decreases the threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrBiasNormalNotification 1.3.6.1.4.1.6141.2.60.4.2.0.14
A wwpLeosPortXcvrBiasNormalNotification is sent if the Xcvr Bias returns back to normal state.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrTxPowerHighNotification 1.3.6.1.4.1.6141.2.60.4.2.0.15
A wwpLeosPortXcvrTxPowerHighNotification is sent if the Xcvr TxPower exceeds the threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrTxPowerLowNotification 1.3.6.1.4.1.6141.2.60.4.2.0.16
A wwpLeosPortXcvrTxPowerLowNotification is sent if the Xcvr voltage decreases the threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrTxPowerNormalNotification 1.3.6.1.4.1.6141.2.60.4.2.0.17
A wwpLeosPortXcvrTxPowerNormalNotification is sent if the Xcvr TxPower returns back to normal state.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrRxPowerHighNotification 1.3.6.1.4.1.6141.2.60.4.2.0.18
A wwpLeosPortXcvrRxPowerHighNotification is sent if the Xcvr RxPower exceeds the threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrRxPowerLowNotification 1.3.6.1.4.1.6141.2.60.4.2.0.19
A wwpLeosPortXcvrRxPowerLowNotification is sent if the Xcvr voltage decreases the threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrRxPowerNormalNotification 1.3.6.1.4.1.6141.2.60.4.2.0.20
A wwpLeosPortXcvrRxPowerNormalNotification is sent if the Xcvr RxPower returns back to normal state.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrSpeedInfoMissingNotification 1.3.6.1.4.1.6141.2.60.4.2.0.21
A wwpLeosPortXcvrSpeedInfoMissingNotification is sent if the Xcvr speed information is not found.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrBiasHighWarningNotification 1.3.6.1.4.1.6141.2.60.4.2.0.22
A wwpLeosPortXcvrBiasHighNotification is sent if the Xcvr Bias exceeds the warning threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrBiasLowWarningNotification 1.3.6.1.4.1.6141.2.60.4.2.0.23
A wwpLeosPortXcvrBiasLowNotification is sent if the Xcvr voltage decreases below the warning threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrTempHighWarningNotification 1.3.6.1.4.1.6141.2.60.4.2.0.24
A wwpLeosPortXcvrTempHighNotification is sent if the Xcvr temperature exceeds the warning threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrTempLowWarningNotification 1.3.6.1.4.1.6141.2.60.4.2.0.25
A wwpLeosPortXcvrTempLowNotification is sent if the Xcvr temperature decreases below the warning threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrVoltageHighWarningNotification 1.3.6.1.4.1.6141.2.60.4.2.0.26
A wwpLeosPortXcvrVoltageHighNotification is sent if the Xcvr voltage exceeds the warning threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrVoltageLowWarningNotification 1.3.6.1.4.1.6141.2.60.4.2.0.27
A wwpLeosPortXcvrVoltageLowNotification is sent if the Xcvr voltage decreases below the warning threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrTxPowerHighWarningNotification 1.3.6.1.4.1.6141.2.60.4.2.0.28
A wwpLeosPortXcvrTxPowerHighNotification is sent if the Xcvr TxPower exceeds the warning threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrTxPowerLowWarningNotification 1.3.6.1.4.1.6141.2.60.4.2.0.29
A wwpLeosPortXcvrTxPowerLowNotification is sent if the Xcvr TxPower decreases below the warning threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrRxPowerHighWarningNotification 1.3.6.1.4.1.6141.2.60.4.2.0.30
A wwpLeosPortXcvrRxPowerHighNotification is sent if the Xcvr RxPower exceeds the warning threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

wwpLeosPortXcvrRxPowerLowWarningNotification 1.3.6.1.4.1.6141.2.60.4.2.0.31
A wwpLeosPortXcvrRxPowerLowNotification is sent if the Xcvr RxPower decreases below the warning threshold.
Status: current Access: read-only
NOTIFICATION-TYPE