VERILINK-ENTERPRISE-NCMM13-MIB

File: VERILINK-ENTERPRISE-NCMM13-MIB.mib (93373 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212
VERILINK-ENTERPRISE-NCMALARM-MIB

Imported symbols

Gauge DisplayString OBJECT-TYPE
ncm-m13

Defined Types

Ncmm13DS3PortEntry  
SEQUENCE    
  ncmm13DS3PortNIDIndex INTEGER
  ncmm13DS3PortIndex INTEGER
  ncmm13DS3ModeControl INTEGER
  ncmm13DS3LineType INTEGER
  ncmm13DS3PerfControl INTEGER
  ncmm13DS3AlarmControl INTEGER
  ncmm13DS3FarEndControl INTEGER
  ncmm13DS3BusType INTEGER
  ncmm13DS3InbandControl INTEGER
  ncmm13DS3CableLength INTEGER
  ncmm13DS3EquipCode DisplayString
  ncmm13DS3LocationIDCode DisplayString
  ncmm13DS3FrameIDCode DisplayString
  ncmm13DS3UnitCode DisplayString
  ncmm13DS3FacilityIDCode DisplayString
  ncmm13DS3PortIdCode DisplayString
  ncmm13DS3GenIDCode DisplayString

Ncmm13StatEntry  
SEQUENCE    
  ncmm13StatNIDIndex INTEGER
  ncmm13StatIndex INTEGER
  ncmm13StatAIS INTEGER
  ncmm13StatIdle INTEGER
  ncmm13StatYellowAlm INTEGER
  ncmm13StatOOF INTEGER
  ncmm13StatLOS INTEGER
  ncmm13DS3NearEndLocalLoopback INTEGER
  ncmm13DS3NearEndLineLoopback INTEGER
  ncmm13DS3FarEndLineLoopback INTEGER
  ncmm13T1NearEndLineLoopback DisplayString
  ncmm13T1FarEndLineLoopback DisplayString
  ncmm13FarEndAllT1LineLoopback INTEGER
  ncmm13T1LocalLoopback DisplayString

Ncmm13CurrentEntry  
SEQUENCE    
  ncmm13CurrentNIDIndex INTEGER
  ncmm13CurrentIndex INTEGER
  ncmm13CurrentCRCStatus INTEGER
  ncmm13CurrentTimeStampSecs INTEGER
  ncmm13CurrentTimeStampMSecs INTEGER
  ncmm13CurrentIntervalSecsElaps INTEGER
  ncmm13CurrentFarEndCCV Gauge
  ncmm13CurrentFarEndCES Gauge
  ncmm13CurrentFarEndCSES Gauge
  ncmm13CurrentFarEndLUAS Gauge
  ncmm13CurrentLCV Gauge
  ncmm13CurrentLES Gauge
  ncmm13CurrentLSES Gauge
  ncmm13CurrentPCV Gauge
  ncmm13CurrentPES Gauge
  ncmm13CurrentPSES Gauge
  ncmm13CurrentCCV Gauge
  ncmm13CurrentCES Gauge
  ncmm13CurrentCSES Gauge
  ncmm13CurrentSEFS Gauge
  ncmm13CurrentAISS Gauge
  ncmm13CurrentLUAS Gauge
  ncmm13CurrentLOOS Gauge
  ncmm13CurrentLOFS Gauge

Ncmm13IntervalEntry  
SEQUENCE    
  ncmm13IntervalNIDIndex INTEGER
  ncmm13IntervalIndex INTEGER
  ncmm13IntervalNumber INTEGER
  ncmm13IntervalFarEndCCV Gauge
  ncmm13IntervalFarEndCES Gauge
  ncmm13IntervalFarEndCSES Gauge
  ncmm13IntervalFarEndLUAS Gauge
  ncmm13IntervalLCV Gauge
  ncmm13IntervalLES Gauge
  ncmm13IntervalLSES Gauge
  ncmm13IntervalPCV Gauge
  ncmm13IntervalPES Gauge
  ncmm13IntervalPSES Gauge
  ncmm13IntervalCCV Gauge
  ncmm13IntervalCES Gauge
  ncmm13IntervalCSES Gauge
  ncmm13IntervalSEFS Gauge
  ncmm13IntervalAISS Gauge
  ncmm13IntervalLUAS Gauge
  ncmm13IntervalLOSS Gauge
  ncmm13IntervalLOFS Gauge

Ncmm13TotalEntry  
SEQUENCE    
  ncmm13TotalNIDIndex INTEGER
  ncmm13TotalIndex INTEGER
  ncmm13TotalCRCStatus INTEGER
  ncmm13TotalValidInterv INTEGER
  ncmm13TotalFarEndCCV Gauge
  ncmm13TotalFarEndCES Gauge
  ncmm13TotalFarEndCSES Gauge
  ncmm13TotalFarEndLUAS Gauge
  ncmm13TotalLCV Gauge
  ncmm13TotalLES Gauge
  ncmm13TotalLSES Gauge
  ncmm13TotalPCV Gauge
  ncmm13TotalPES Gauge
  ncmm13TotalPSES Gauge
  ncmm13TotalCCV Gauge
  ncmm13TotalCES Gauge
  ncmm13TotalCSES Gauge
  ncmm13TotalSEFS Gauge
  ncmm13TotalAISS Gauge
  ncmm13TotalLUAS Gauge
  ncmm13TotalLOSS Gauge
  ncmm13TotalLOFS Gauge

Ncmm13PerformanceSnapShotEntry  
SEQUENCE    
  ncmm13SnapShotNIDIndex INTEGER
  ncmm13SnapShotIndex INTEGER
  ncmm13SnapShotCRCStatus INTEGER
  ncmm13SnapShot INTEGER
  ncmm13TimeStampSec INTEGER
  ncmm13TimeStampMilliSec INTEGER
  ncmm13SnapShotSecs INTEGER
  ncmm13ResetPerfReg INTEGER

Ncmm13TCAQtrEntry  
SEQUENCE    
  ncmm13TCAQtrNIDIndex INTEGER
  ncmm13TCAQtrIndex INTEGER
  ncmm13TCAQtrFarEndCCV INTEGER
  ncmm13TCAQtrFarEndCES INTEGER
  ncmm13TCAQtrFarEndCSES INTEGER
  ncmm13TCAQtrFarEndLUAS INTEGER
  ncmm13TCAQtrLCV INTEGER
  ncmm13TCAQtrLES INTEGER
  ncmm13TCAQtrLSES INTEGER
  ncmm13TCAQtrPCV INTEGER
  ncmm13TCAQtrPES INTEGER
  ncmm13TCAQtrPSES INTEGER
  ncmm13TCAQtrCCV INTEGER
  ncmm13TCAQtrCES INTEGER
  ncmm13TCAQtrCSES INTEGER
  ncmm13TCAQtrSEFS INTEGER
  ncmm13TCAQtrAISS INTEGER
  ncmm13TCAQtrLUAS INTEGER
  ncmm13TCAQtrLOSS INTEGER
  ncmm13TCAQtrLOFS INTEGER

Ncmm13TCADayEntry  
SEQUENCE    
  ncmm13TCADayNIDIndex INTEGER
  ncmm13TCADayIndex INTEGER
  ncmm13TCADayFarEndCCV INTEGER
  ncmm13TCADayFarEndCES INTEGER
  ncmm13TCADayFarEndCSES INTEGER
  ncmm13TCADayFarEndLUAS INTEGER
  ncmm13TCADayLCV INTEGER
  ncmm13TCADayLES INTEGER
  ncmm13TCADayLSES INTEGER
  ncmm13TCADayPCV INTEGER
  ncmm13TCADayPES INTEGER
  ncmm13TCADayPSES INTEGER
  ncmm13TCADayCCV INTEGER
  ncmm13TCADayCES INTEGER
  ncmm13TCADayCSES INTEGER
  ncmm13TCADaySEFS INTEGER
  ncmm13TCADayAISS INTEGER
  ncmm13TCADayLUAS INTEGER
  ncmm13TCADayLOSS INTEGER
  ncmm13TCADayLOFS INTEGER

Ncmm13TxAlarmEntry  
SEQUENCE    
  ncmm13TxAlarmNIDIndex INTEGER
  ncmm13TxAlarmIndex INTEGER
  ncmm13TxYellowAlarm INTEGER
  ncmm13TxAIS INTEGER
  ncmm13TxIdleSignal INTEGER
  ncmm13TxFEBE INTEGER
  ncmm13TxFEACAlarm INTEGER

Ncmm13DS3LPBKEntry  
SEQUENCE    
  ncmm13DS3LPBKNIDIndex INTEGER
  ncmm13DS3LPBKIndex INTEGER
  ncmm13DS3LPBKAction INTEGER

Ncmm13T1LPBKEntry  
SEQUENCE    
  ncmm13T1LPBKNIDIndex INTEGER
  ncmm13T1LPBKIndex INTEGER
  ncmm13T1LPBKAction INTEGER

Ncmm13T1ConfigEntry  
SEQUENCE    
  ncmm13T1ConfigNIDIndex INTEGER
  ncmm13T1LineIndex INTEGER
  ncmm13T1FramingFormat INTEGER
  ncmm13T1LineCoding INTEGER
  ncmm13T1EnableNetOnesDensity INTEGER
  ncmm13T1DensityPattern INTEGER
  ncmm13T1PortService INTEGER

Defined Values

ncmm13DS3PortTable 1.3.6.1.4.1.321.1.3037.14000
The m13 DS3 Port table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ncmm13DS3PortEntry

ncmm13DS3PortEntry 1.3.6.1.4.1.321.1.3037.14000.1
An entry in the m13 information table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ncmm13DS3PortEntry  

ncmm13DS3PortNIDIndex 1.3.6.1.4.1.321.1.3037.14000.1.1
This variable indicates the node id value of the node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

ncmm13DS3PortIndex 1.3.6.1.4.1.321.1.3037.14000.1.2
The index value which uniquely identifies the DS3 interface to which this entry is applica- ble. The interface identified by a particular value of this index is the same interface as identified by the same value as a dsx1LineIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

ncmm13DS3ModeControl 1.3.6.1.4.1.321.1.3037.14000.1.3
The Mode Control Bit for M13.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER c-bit(1), m23-bit(2)  

ncmm13DS3LineType 1.3.6.1.4.1.321.1.3037.14000.1.4
The Line Type for M13.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER bi-polar(1), uni-polar(2)  

ncmm13DS3PerfControl 1.3.6.1.4.1.321.1.3037.14000.1.5
Performance Control Enabled/Disabled for M13.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

ncmm13DS3AlarmControl 1.3.6.1.4.1.321.1.3037.14000.1.6
Alarm Control Enabled/Disabled for M13.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

ncmm13DS3FarEndControl 1.3.6.1.4.1.321.1.3037.14000.1.7
Far End Control Enabled/Disabled for M13.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

ncmm13DS3BusType 1.3.6.1.4.1.321.1.3037.14000.1.8
Inband Control Enabled/Disabled for M13.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER c-bus(1), a-bus(2)  

ncmm13DS3InbandControl 1.3.6.1.4.1.321.1.3037.14000.1.9
Inband Control Enabled/Disabled for M13.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

ncmm13DS3CableLength 1.3.6.1.4.1.321.1.3037.14000.1.10
Cable length for M13.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER short(1), long(2)  

ncmm13DS3EquipCode 1.3.6.1.4.1.321.1.3037.14000.1.11
This is the Far End Equipment Identification code that describes the specific piece of equipment. It is sent within the Path Identification Message.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..10)  

ncmm13DS3LocationIDCode 1.3.6.1.4.1.321.1.3037.14000.1.12
This is the Far End Location Identification code that describes the specific location of the equipment. It is sent within the Path Identification Message.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..11)  

ncmm13DS3FrameIDCode 1.3.6.1.4.1.321.1.3037.14000.1.13
This is the Far End Frame Identification code that identifies where the equipment is located within a building at a given location. It is sent within the Path Identification Message.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..10)  

ncmm13DS3UnitCode 1.3.6.1.4.1.321.1.3037.14000.1.14
This is the Far End code that identifies the equipment location within a bay. It is sent within the Path Identification Message.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..6)  

ncmm13DS3FacilityIDCode 1.3.6.1.4.1.321.1.3037.14000.1.15
This code identifies a specific Far End DS3 path. It is sent within the Path Identification Message.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..38)  

ncmm13DS3PortIdCode 1.3.6.1.4.1.321.1.3037.14000.1.16
Port ID.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..38)  

ncmm13DS3GenIDCode 1.3.6.1.4.1.321.1.3037.14000.1.17
Test Signal Generator ID.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..38)  

ncmm13StatTable 1.3.6.1.4.1.321.1.3037.14001
The m13 Stats.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ncmm13StatEntry

ncmm13StatEntry 1.3.6.1.4.1.321.1.3037.14001.1
An entry in the m13 stats table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ncmm13StatEntry  

ncmm13StatNIDIndex 1.3.6.1.4.1.321.1.3037.14001.1.1
This variable indicates the node id value of the node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

ncmm13StatIndex 1.3.6.1.4.1.321.1.3037.14001.1.2
The index value which uniquely identifies the DS1 interface to which this entry is applica- ble. The interface identified by a particular value of this index is the same interface as identified by the same value as a dsx1LineIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

ncmm13StatAIS 1.3.6.1.4.1.321.1.3037.14001.1.3
Port Status m13 AIS off/on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER oFF(1), oN(2)  

ncmm13StatIdle 1.3.6.1.4.1.321.1.3037.14001.1.4
port Status m13 Idle off/on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER oFF(1), oN(2)  

ncmm13StatYellowAlm 1.3.6.1.4.1.321.1.3037.14001.1.5
Port Status m13 Yellow Alarm off/on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER oFF(1), oN(2)  

ncmm13StatOOF 1.3.6.1.4.1.321.1.3037.14001.1.6
port status m13 off/on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER oFF(1), oN(2)  

ncmm13StatLOS 1.3.6.1.4.1.321.1.3037.14001.1.7
Port Status m13 LOS off/on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER oFF(1), oN(2)  

ncmm13DS3NearEndLocalLoopback 1.3.6.1.4.1.321.1.3037.14001.1.8
Port Status m13 Ds3 Local Loopback off/on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER oFF(1), oN(2)  

ncmm13DS3NearEndLineLoopback 1.3.6.1.4.1.321.1.3037.14001.1.9
Port Status m13 ds3 near end Line loopback off/on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER oFF(1), oN(2)  

ncmm13DS3FarEndLineLoopback 1.3.6.1.4.1.321.1.3037.14001.1.10
Port Status m13 ds3 far end line loopback off/on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER oFF(1), oN(2)  

ncmm13T1NearEndLineLoopback 1.3.6.1.4.1.321.1.3037.14001.1.11
Port Status m13 T1 near end line loopback.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ncmm13T1FarEndLineLoopback 1.3.6.1.4.1.321.1.3037.14001.1.12
Port Status m13 T1 Far end line loopback.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ncmm13FarEndAllT1LineLoopback 1.3.6.1.4.1.321.1.3037.14001.1.13
Port Status m13 T1 Far End All T1 Line Loopback.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

ncmm13T1LocalLoopback 1.3.6.1.4.1.321.1.3037.14001.1.14
Port Status m13 T1 Local loopback.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ncmm13CurrentTable 1.3.6.1.4.1.321.1.3037.14002
The m13 Current table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ncmm13CurrentEntry

ncmm13CurrentEntry 1.3.6.1.4.1.321.1.3037.14002.1
An entry in the m13 Current table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ncmm13CurrentEntry  

ncmm13CurrentNIDIndex 1.3.6.1.4.1.321.1.3037.14002.1.1
This variable indicates the node id value of the node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

ncmm13CurrentIndex 1.3.6.1.4.1.321.1.3037.14002.1.2
The index value which uniquely identifies the m13 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an ncmhdmLineIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

ncmm13CurrentCRCStatus 1.3.6.1.4.1.321.1.3037.14002.1.3
Current CRC4 Status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1)  

ncmm13CurrentTimeStampSecs 1.3.6.1.4.1.321.1.3037.14002.1.4
Current Time in seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

ncmm13CurrentTimeStampMSecs 1.3.6.1.4.1.321.1.3037.14002.1.5
Current Time in milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

ncmm13CurrentIntervalSecsElaps 1.3.6.1.4.1.321.1.3037.14002.1.6
Seconds elapsed in the current interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

ncmm13CurrentFarEndCCV 1.3.6.1.4.1.321.1.3037.14002.1.7
The counter associated with the number of Far End C-bit Code Violations, in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13CurrentFarEndCES 1.3.6.1.4.1.321.1.3037.14002.1.8
The counter associated with the number of Far End C-bit Errored Seconds, in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13CurrentFarEndCSES 1.3.6.1.4.1.321.1.3037.14002.1.9
The counter associated with the number of Far End C-bit Severely Errored Seconds, in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13CurrentFarEndLUAS 1.3.6.1.4.1.321.1.3037.14002.1.10
Far End Line Unavailable Seconds. The counter associated with the number of Seconds the Far End m13 interface was Out Of Service in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13CurrentLCV 1.3.6.1.4.1.321.1.3037.14002.1.11
The counter associated with the number of Line Code Violations, a bipolar or excesive zero violation, in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13CurrentLES 1.3.6.1.4.1.321.1.3037.14002.1.12
Line Errored Second Total. The counter associated with the number of Seconds of in which one or more LCV occurred in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13CurrentLSES 1.3.6.1.4.1.321.1.3037.14002.1.13
The counter associated with the number of Line Severely Errored Seconds (LSES) in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13CurrentPCV 1.3.6.1.4.1.321.1.3037.14002.1.14
The counter associated with the number of Parity Code Violations (locally calculated P-bits disagree with those received), in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13CurrentPES 1.3.6.1.4.1.321.1.3037.14002.1.15
The counter associated with the number of Seconds having at least one Parity Code Violation, in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13CurrentPSES 1.3.6.1.4.1.321.1.3037.14002.1.16
The counter associated with the number of Seconds having 44 or more Parity Code Violations, in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13CurrentCCV 1.3.6.1.4.1.321.1.3037.14002.1.17
The counter associated with the number of C-bit Code Violations, in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13CurrentCES 1.3.6.1.4.1.321.1.3037.14002.1.18
The counter associated with the number of C-bit Errored Seconds, in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13CurrentCSES 1.3.6.1.4.1.321.1.3037.14002.1.19
The counter associated with the number of C-bit Severely Errored Seconds, in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13CurrentSEFS 1.3.6.1.4.1.321.1.3037.14002.1.20
The counter associated with the number of seconds in which one or more Out of Frame occurred in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13CurrentAISS 1.3.6.1.4.1.321.1.3037.14002.1.21
The counter associated with the number of Seconds in which one or more incoming AISS was detected in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13CurrentLUAS 1.3.6.1.4.1.321.1.3037.14002.1.22
The counter associated with the number of Seconds in which one or more incoming LUAS was detected in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13CurrentLOOS 1.3.6.1.4.1.321.1.3037.14002.1.23
The counter associated with the number of Seconds the m13 interface was Out Of Service in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13CurrentLOFS 1.3.6.1.4.1.321.1.3037.14002.1.24
The counter associated with the number of Seconds Of system Loss Of Signal (LOS) in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13IntervalTable 1.3.6.1.4.1.321.1.3037.14003
The DS3/E3 Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ncmm13IntervalEntry

ncmm13IntervalEntry 1.3.6.1.4.1.321.1.3037.14003.1
An entry in the m13 Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ncmm13IntervalEntry  

ncmm13IntervalNIDIndex 1.3.6.1.4.1.321.1.3037.14003.1.1
This variable indicates the node id value of the node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

ncmm13IntervalIndex 1.3.6.1.4.1.321.1.3037.14003.1.2
The index value which uniquely identifies the m13 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an ncmhdmLineIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

ncmm13IntervalNumber 1.3.6.1.4.1.321.1.3037.14003.1.3
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes inter- val (assuming that all 96 intervals are valid).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..96  

ncmm13IntervalFarEndCCV 1.3.6.1.4.1.321.1.3037.14003.1.4
The counter associated with the number of Far End C-bit Code Violations, in the previous 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13IntervalFarEndCES 1.3.6.1.4.1.321.1.3037.14003.1.5
The counter associated with the number of Far End C-bit Errored Seconds, in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13IntervalFarEndCSES 1.3.6.1.4.1.321.1.3037.14003.1.6
The counter associated with the number of Far End C-bit Severely Errored Seconds, in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13IntervalFarEndLUAS 1.3.6.1.4.1.321.1.3037.14003.1.7
Far End Line Unavailable Seconds. The counter associated with the number of Seconds the Far End m13 interface was Out Of Service in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13IntervalLCV 1.3.6.1.4.1.321.1.3037.14003.1.8
The counter associated with the number of Line Code Violations, a bipolar or excesive zero violation, in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13IntervalLES 1.3.6.1.4.1.321.1.3037.14003.1.9
Line Errored Second Total. The counter associated with the number of Seconds of in which one or more LCV occurred in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13IntervalLSES 1.3.6.1.4.1.321.1.3037.14003.1.10
The counter associated with the number of Line Severely Errored Seconds (LSES) in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13IntervalPCV 1.3.6.1.4.1.321.1.3037.14003.1.11
The counter associated with the number of Parity Code Violations (locally calculated P-bits disagree with those received), in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13IntervalPES 1.3.6.1.4.1.321.1.3037.14003.1.12
The counter associated with the number of Seconds having at least one Parity Code Violation, in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13IntervalPSES 1.3.6.1.4.1.321.1.3037.14003.1.13
The counter associated with the number of Seconds having 44 or more Parity Code Violations, in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13IntervalCCV 1.3.6.1.4.1.321.1.3037.14003.1.14
The counter associated with the number of C-bit Code Violations, in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13IntervalCES 1.3.6.1.4.1.321.1.3037.14003.1.15
The counter associated with the number of C-bit Errored Seconds, in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13IntervalCSES 1.3.6.1.4.1.321.1.3037.14003.1.16
The counter associated with the number of C-bit Severely Errored Seconds, in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13IntervalSEFS 1.3.6.1.4.1.321.1.3037.14003.1.17
The counter associated with the number of seconds in which one or more Out of Frame occurred in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13IntervalAISS 1.3.6.1.4.1.321.1.3037.14003.1.18
The counter associated with the number of Seconds in which one or more incoming AIS was detected in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13IntervalLUAS 1.3.6.1.4.1.321.1.3037.14003.1.19
The counter associated with the number of Seconds the m13 interface was Out Of Service in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13IntervalLOSS 1.3.6.1.4.1.321.1.3037.14003.1.20
The counter associated with the number of Seconds Of system Loss Of Signal (LOS) in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13IntervalLOFS 1.3.6.1.4.1.321.1.3037.14003.1.21
The counter associated with the number of Seconds Of system Loss Of Frame (LOF) in the current 15 minute interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13TotalTable 1.3.6.1.4.1.321.1.3037.14004
The m13 Total table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ncmm13TotalEntry

ncmm13TotalEntry 1.3.6.1.4.1.321.1.3037.14004.1
An entry in the m13 Total table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ncmm13TotalEntry  

ncmm13TotalNIDIndex 1.3.6.1.4.1.321.1.3037.14004.1.1
This variable indicates the node id value of the node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

ncmm13TotalIndex 1.3.6.1.4.1.321.1.3037.14004.1.2
The index value which uniquely identifies the m13 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an ncmhdmLineIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

ncmm13TotalCRCStatus 1.3.6.1.4.1.321.1.3037.14004.1.3
CRC4 Status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1)  

ncmm13TotalValidInterv 1.3.6.1.4.1.321.1.3037.14004.1.4
The number of valid intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

ncmm13TotalFarEndCCV 1.3.6.1.4.1.321.1.3037.14004.1.5
The counter associated with the number of Far End C-bit Code Violations, in the last 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13TotalFarEndCES 1.3.6.1.4.1.321.1.3037.14004.1.6
The counter associated with the number of Far End C-bit Errored Seconds, in the last 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13TotalFarEndCSES 1.3.6.1.4.1.321.1.3037.14004.1.7
The counter associated with the number of Far End C-bit Severely Errored Seconds, in the last 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13TotalFarEndLUAS 1.3.6.1.4.1.321.1.3037.14004.1.8
Far End Line Unavailable Seconds. The counter associated with the number of Seconds the Far End m13 interface was Out Of Service in the last 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13TotalLCV 1.3.6.1.4.1.321.1.3037.14004.1.9
The counter associated with the number of Line Code Violations, a bipolar or excesive zero violation, in the last 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13TotalLES 1.3.6.1.4.1.321.1.3037.14004.1.10
Line Errored Second Total. The counter associated with the number of Seconds of in which one or more LCV occurred in the last 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13TotalLSES 1.3.6.1.4.1.321.1.3037.14004.1.11
The counter associated with the number of Seconds Of Line Severely Errored Seconds (LSES) in the last 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13TotalPCV 1.3.6.1.4.1.321.1.3037.14004.1.12
The counter associated with the number of Parity Code Violations (locally calculated P-bits disagree with those received), in the last 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13TotalPES 1.3.6.1.4.1.321.1.3037.14004.1.13
The counter associated with the number of Seconds having at least one Parity Code Violation, in the last 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13TotalPSES 1.3.6.1.4.1.321.1.3037.14004.1.14
The counter associated with the number of Seconds having 44 or more Parity Code Violations, in the last 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13TotalCCV 1.3.6.1.4.1.321.1.3037.14004.1.15
The counter associated with the number of C-bit Code Violations, in the last 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13TotalCES 1.3.6.1.4.1.321.1.3037.14004.1.16
The counter associated with the number of C-bit Errored Seconds, in the last 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13TotalCSES 1.3.6.1.4.1.321.1.3037.14004.1.17
The counter associated with the number of C-bit Severely Errored Seconds, in the last 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13TotalSEFS 1.3.6.1.4.1.321.1.3037.14004.1.18
The counter associated with the number of seconds in which one or more Out of Frame occurred in the last 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13TotalAISS 1.3.6.1.4.1.321.1.3037.14004.1.19
The counter associated with the number of Seconds in which one or more incoming AIS was detected in the last 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13TotalLUAS 1.3.6.1.4.1.321.1.3037.14004.1.20
The counter associated with the number of Seconds the m13 interface was Out Of Service in the last 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13TotalLOSS 1.3.6.1.4.1.321.1.3037.14004.1.21
The counter associated with the number of Seconds Of system Loss Of Signal (LOS) in the last 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13TotalLOFS 1.3.6.1.4.1.321.1.3037.14004.1.22
The counter associated with the number of Seconds Of system Loss Of Frame (LOF) in the last 24 hour interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ncmm13PerformanceSnapShotTable 1.3.6.1.4.1.321.1.3037.14005
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ncmm13PerformanceSnapShotEntry

ncmm13PerformanceSnapShotEntry 1.3.6.1.4.1.321.1.3037.14005.1
An entry in the m13 Performance Snap Shot Entry table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ncmm13PerformanceSnapShotEntry  

ncmm13SnapShotNIDIndex 1.3.6.1.4.1.321.1.3037.14005.1.1
The object specifies the node id index of the node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

ncmm13SnapShotIndex 1.3.6.1.4.1.321.1.3037.14005.1.2
The index value which uniquely identifies the m13 interface to which this entry is applica- ble. The interface identified by a particular value of this index is the same interface as identified by the same value as a LineIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

ncmm13SnapShotCRCStatus 1.3.6.1.4.1.321.1.3037.14005.1.3
CRC4 Status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1)  

ncmm13SnapShot 1.3.6.1.4.1.321.1.3037.14005.1.4
The variable specifies the option to initiate snap shot command.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

ncmm13TimeStampSec 1.3.6.1.4.1.321.1.3037.14005.1.5
The variable specifies the Time Stamp in Seconds .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

ncmm13TimeStampMilliSec 1.3.6.1.4.1.321.1.3037.14005.1.6
The variable specifies the Time Stamp in milli Seconds .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

ncmm13SnapShotSecs 1.3.6.1.4.1.321.1.3037.14005.1.7
The variable specifies number of seconds in the current interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

ncmm13ResetPerfReg 1.3.6.1.4.1.321.1.3037.14005.1.8
Reset Performance Monitoring registers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

ncmm13TCAQtrTable 1.3.6.1.4.1.321.1.3037.14006
The quarter hour Alert Threshold Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ncmm13TCAQtrEntry

ncmm13TCAQtrEntry 1.3.6.1.4.1.321.1.3037.14006.1
An entry in the m13 table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ncmm13TCAQtrEntry  

ncmm13TCAQtrNIDIndex 1.3.6.1.4.1.321.1.3037.14006.1.1
This variable indicates the node id value of the node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

ncmm13TCAQtrIndex 1.3.6.1.4.1.321.1.3037.14006.1.2
The index value which uniquely identifies the alert crossing threshold interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an plcpLineIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

ncmm13TCAQtrFarEndCCV 1.3.6.1.4.1.321.1.3037.14006.1.3
The performance alert threshold for m13 layer Far End C-bit Code Violation in 1/4 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCAQtrFarEndCES 1.3.6.1.4.1.321.1.3037.14006.1.4
The performance alert threshold for m13 Far End C-bit Errored Seconds, in 1/4 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCAQtrFarEndCSES 1.3.6.1.4.1.321.1.3037.14006.1.5
The performance alert threshold for m13 Far End C-bit Severely Errored Seconds, in 1/4 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCAQtrFarEndLUAS 1.3.6.1.4.1.321.1.3037.14006.1.6
The performance alert threshold for m13 layer Far End Line Unavailable Seconds in 1/4 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCAQtrLCV 1.3.6.1.4.1.321.1.3037.14006.1.7
The performance alert threshold for m13 layer Line code Violation in 1/4 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCAQtrLES 1.3.6.1.4.1.321.1.3037.14006.1.8
The performance alert threshold for m13 layer Line Errored Second in 1/4 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCAQtrLSES 1.3.6.1.4.1.321.1.3037.14006.1.9
The performance alert threshold for m13 layer Line Severely Errored Second in 1/4 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCAQtrPCV 1.3.6.1.4.1.321.1.3037.14006.1.10
The performance alert threshold for m13 layer Parity Code Violation in 1/4 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCAQtrPES 1.3.6.1.4.1.321.1.3037.14006.1.11
The performance alert threshold for m13 layer Parity Errored Second in 1/4 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCAQtrPSES 1.3.6.1.4.1.321.1.3037.14006.1.12
The performance alert threshold for m13 layer Parity Severely Errored Second in 1/4 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCAQtrCCV 1.3.6.1.4.1.321.1.3037.14006.1.13
The performance alert threshold for m13 layer C-bit Code Violation in 1/4 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCAQtrCES 1.3.6.1.4.1.321.1.3037.14006.1.14
The performance alert threshold for m13 Far End C-bit Errored Seconds, layer Errored Second in 1/4 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCAQtrCSES 1.3.6.1.4.1.321.1.3037.14006.1.15
The performance alert threshold for m13 layer C-bit Severely Errored Second in 1/4 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCAQtrSEFS 1.3.6.1.4.1.321.1.3037.14006.1.16
The performance alert threshold for m13 layer Severely Errored Framing Seconds in 1/4 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCAQtrAISS 1.3.6.1.4.1.321.1.3037.14006.1.17
The performance alert threshold for m13 layer Alarm Indication Signal Second in 1/4 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCAQtrLUAS 1.3.6.1.4.1.321.1.3037.14006.1.18
The performance alert threshold for m13 layer Unavailable Second in 1/4 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCAQtrLOSS 1.3.6.1.4.1.321.1.3037.14006.1.19
The performance alert threshold for m13 Loss of Signal (LOS) Seconds in 1/4 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCAQtrLOFS 1.3.6.1.4.1.321.1.3037.14006.1.20
The performance alert threshold for m13 Loss of Frame (LOF) Seconds in 1/4 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCADayTable 1.3.6.1.4.1.321.1.3037.14007
The 24 hour m13 Alert Threshold Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ncmm13TCADayEntry

ncmm13TCADayEntry 1.3.6.1.4.1.321.1.3037.14007.1
An entry in the 24 hour m13 Alert Threshold Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ncmm13TCADayEntry  

ncmm13TCADayNIDIndex 1.3.6.1.4.1.321.1.3037.14007.1.1
This variable indicates the node id value of the node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

ncmm13TCADayIndex 1.3.6.1.4.1.321.1.3037.14007.1.2
The index value which uniquely identifies the alert crossing threshold interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an plcpLineIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

ncmm13TCADayFarEndCCV 1.3.6.1.4.1.321.1.3037.14007.1.3
The performance alert threshold for m13 layer Far End C-bit Code Violation in 24 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCADayFarEndCES 1.3.6.1.4.1.321.1.3037.14007.1.4
The performance alert threshold for m13 Far End C-bit Errored Seconds, in 24 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCADayFarEndCSES 1.3.6.1.4.1.321.1.3037.14007.1.5
The performance alert threshold for m13 Far End C-bit Severely Errored Seconds, in 24 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCADayFarEndLUAS 1.3.6.1.4.1.321.1.3037.14007.1.6
The performance alert threshold for m13 layer Far End Line Unavailable Seconds in 24 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCADayLCV 1.3.6.1.4.1.321.1.3037.14007.1.7
The performance alert threshold for m13 layer Line code Violation in 24 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCADayLES 1.3.6.1.4.1.321.1.3037.14007.1.8
The performance alert threshold for m13 layer Line Errored Second in 24 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCADayLSES 1.3.6.1.4.1.321.1.3037.14007.1.9
The performance alert threshold for m13 layer Line Severely Errored Second in 24 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCADayPCV 1.3.6.1.4.1.321.1.3037.14007.1.10
The performance alert threshold for m13 layer Parity Code Violation in 24 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCADayPES 1.3.6.1.4.1.321.1.3037.14007.1.11
The performance alert threshold for m13 layer Parity Errored Second in 24 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCADayPSES 1.3.6.1.4.1.321.1.3037.14007.1.12
The performance alert threshold form 13 layer Parity Severely Errored Second in 24 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCADayCCV 1.3.6.1.4.1.321.1.3037.14007.1.13
The performance alert threshold for m13 layer C-bit Code Violation in 24 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCADayCES 1.3.6.1.4.1.321.1.3037.14007.1.14
The performance alert threshold for m13 C-bit Errored Seconds, in 24 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCADayCSES 1.3.6.1.4.1.321.1.3037.14007.1.15
The performance alert threshold for DS3 C-bit Severely Errored Seconds, in 24 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCADaySEFS 1.3.6.1.4.1.321.1.3037.14007.1.16
The performance alert threshold for m13 layer Severely Errored Framing Seconds in 24 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCADayAISS 1.3.6.1.4.1.321.1.3037.14007.1.17
The performance alert threshold for m13 layer Alarm Indication Signal Second in 24 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCADayLUAS 1.3.6.1.4.1.321.1.3037.14007.1.18
The performance alert threshold for m13 layer Unavailable Second in 24 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCADayLOSS 1.3.6.1.4.1.321.1.3037.14007.1.19
The performance alert threshold for m13 Loss of Signal (LOS) Seconds in 24 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TCADayLOFS 1.3.6.1.4.1.321.1.3037.14007.1.20
The performance alert threshold for m13 Loss of Frame (LOF) Seconds in 24 hour boundary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4294967295  

ncmm13TxAlarmTable 1.3.6.1.4.1.321.1.3037.14008
m13 Transmit alarm Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ncmm13TxAlarmEntry

ncmm13TxAlarmEntry 1.3.6.1.4.1.321.1.3037.14008.1
An entry in the m13 Transmit Alarm table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ncmm13TxAlarmEntry  

ncmm13TxAlarmNIDIndex 1.3.6.1.4.1.321.1.3037.14008.1.1
This variable indicates the node id value of the node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

ncmm13TxAlarmIndex 1.3.6.1.4.1.321.1.3037.14008.1.2
The index value which uniquely identifies the Transmit Alarm interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an m13 LineIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

ncmm13TxYellowAlarm 1.3.6.1.4.1.321.1.3037.14008.1.3
Transmit the near-end yellow alarm for m13.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

ncmm13TxAIS 1.3.6.1.4.1.321.1.3037.14008.1.4
Transmit the near-end AIS alarm for m13.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

ncmm13TxIdleSignal 1.3.6.1.4.1.321.1.3037.14008.1.5
Transmit the near-end Idle alarm for m13.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

ncmm13TxFEBE 1.3.6.1.4.1.321.1.3037.14008.1.6
Near end unit transmits the FEBE alarm for m13.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

ncmm13TxFEACAlarm 1.3.6.1.4.1.321.1.3037.14008.1.7
This object describes which, if any, FEAC Alarm is enabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-FEAC-Alarm-enabled(1), eqpt-FailureSA-Alarm(2), los-HBER-Alarm(3), oof-Alarm(4), ais-Received-Alarm(5), idle-Received-Alarm(6), eqpt-NSA-Alarm(7), common-Eqpt-NSA-Alarm(8)  

ncmm13DS3LPBKTable 1.3.6.1.4.1.321.1.3037.14009
The m13 DS3 Loopback table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ncmm13DS3LPBKEntry

ncmm13DS3LPBKEntry 1.3.6.1.4.1.321.1.3037.14009.1
An entry in the m13 Loopback table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ncmm13DS3LPBKEntry  

ncmm13DS3LPBKNIDIndex 1.3.6.1.4.1.321.1.3037.14009.1.1
This variable indicates the node id value of the node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

ncmm13DS3LPBKIndex 1.3.6.1.4.1.321.1.3037.14009.1.2
The index value which uniquely identifies the m13 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an ncmm13LineIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

ncmm13DS3LPBKAction 1.3.6.1.4.1.321.1.3037.14009.1.3
m13 DS3 Loopback Activation/Deactivation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-Loopback(1), m13-DS3-Activate-Local(2), m13-DS3-Activate-Line(3), m13-DS3-Activate-FEAC-Far-End(4), m13-DS3-Activate-Inband-Far-End(5), m13-DS3-DeActivate-Local(6), m13-DS3-DeActivate-Line(7), m13-DS3-DeActivate-FEAC-Far-End(8), m13-DS3-DeActivate-Inband-Far-End(9)  

ncmm13T1LPBKTable 1.3.6.1.4.1.321.1.3037.14010
The m13 Loopback table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ncmm13T1LPBKEntry

ncmm13T1LPBKEntry 1.3.6.1.4.1.321.1.3037.14010.1
An entry in the m13 Loopback table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ncmm13T1LPBKEntry  

ncmm13T1LPBKNIDIndex 1.3.6.1.4.1.321.1.3037.14010.1.1
This variable indicates the node id value of the node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

ncmm13T1LPBKIndex 1.3.6.1.4.1.321.1.3037.14010.1.2
The index value which uniquely identifies the m13 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an ncmm13LineIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

ncmm13T1LPBKAction 1.3.6.1.4.1.321.1.3037.14010.1.3
m13 Loopback Activate if Line Type = 0 (DS3 Loopback) 1 No Active 2 Local Loopback 3 Line Loopback 4 FEAC Far End 5 Inband Far End if Line Type = 1 (T1 Line Command) 6 1-28 T1 Line Loopback if Line Type = 2(T1 Far End Line) 7 1-28 T1 Far End Loopback if Line Type = 3(T1 Local Loopback ) 8 1-28 T1 Local Loopback m13 Loopback DeActivate if Line Type = 0 (DS3 Loopback) 1 No Active 9 Local Loopback 10 Line Loopback 11 FEAC Far End 12 Inband Far End if Line Type = 1 (T1 Line Command) 13 1-28 T1 Line Loopback if Line Type = 2(T1 Far End Line) 14 1-28 T1 Far End Loopback if Line Type = 3(T1 Local Loopback ) 15 1-28 T1 Local Loopback.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-Loopback(1), m13-Activate-1-28-T1-Line(10), m13-Activate-All-T1-Line(11), m13-Activate-1-28-T1-Far-End(12), m13-Activate-All-T1-Far-End(13), m13-Activate-1-28-T1-Local(14), m13-Activate-All-T1-Local(15), m13-DeActivate-1-28-T1-Line(16), m13-DeActivate-All-T1-Line(17), m13-DeActivate-1-28-T1-Far-End(18), m13-DeActivate-All-T1-Far-End(19), m13-DeActivate-1-28-T1-Local(20), m13-DeActivate-All-T1-Local(21)  

ncmm13T1ConfigTable 1.3.6.1.4.1.321.1.3037.14011
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ncmm13T1ConfigEntry

ncmm13T1ConfigEntry 1.3.6.1.4.1.321.1.3037.14011.1
An entry in the ncm m13 T1 Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ncmm13T1ConfigEntry  

ncmm13T1ConfigNIDIndex 1.3.6.1.4.1.321.1.3037.14011.1.1
This object is the identifier of the node id index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

ncmm13T1LineIndex 1.3.6.1.4.1.321.1.3037.14011.1.2
This object is the identifier of a Inter- f on a managed device. If there is an ifEn- try that is directly associated with this and only this m13 interface, it should have the same value as ifIndex. Otherwise, the value exceeds ifNumber, and is a unique identifier following this rule: inside interfaces (e.g., equipment side) with even numbers and outside interfaces (e.g., network side) with odd numbers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

ncmm13T1FramingFormat 1.3.6.1.4.1.321.1.3037.14011.1.3
This variable indicates the variety of Line implementing this circuit. The type of circuit affects the number of bits per second that the circuit can reasonably carry, as well as the interpretation of the usage and error statistics. The values, in sequence, describe: TITLE: SPECIFICATION: ESF Extended SuperFrame DS1 SF Super Frame
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER sF(1), eSF(2)  

ncmm13T1LineCoding 1.3.6.1.4.1.321.1.3037.14011.1.4
This variable describes the variety of Zero Code Suppression used on the link, which in turn affects a number of its characteristics. B8ZS refers to the use of a specified pat- tern of normal bits and bipolar violations which are used to replace a sequence of eight zero bits. AMI refers to a mode wherein no zero code suppression is present and the line encoding does not solve the problem directly. In this application, the higher layer must provide data which meets or exceeds the pulse density re- quirements, such as inverting HDLC data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER aMI(1), b8ZS(2)  

ncmm13T1EnableNetOnesDensity 1.3.6.1.4.1.321.1.3037.14011.1.5
The variable specifies the Disable/Enable of the Network One's Density.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

ncmm13T1DensityPattern 1.3.6.1.4.1.321.1.3037.14011.1.6
This variable indicates what type of density network is being sent on the port or line by the device. The values mean : 'Disabled' refers to no network ones density exist. 'D80Zeros' refers to send a request for network one's density of 80 zeroes density pattern. 'D15Zeros' refers to send a request for network one's density of 15 zeroes density pattern. 'D12d5c80Zero'refers to send a request for 12.5% and 80 zeroes network one's density pattern. 'TR-62411' refers to sending a request for TR6241 network density pattern. 'Other' refers to sending a network's density pattern other than those described by this object[pvt]**.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER d80Zeros(1), d15Zeros(2), d12d5c80Zero(3), tR-62411(4)  

ncmm13T1PortService 1.3.6.1.4.1.321.1.3037.14011.1.7
The variable specifies whether port state is in service or not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER out-of-service(1), in-service(2)