Unisphere-Data-ERX-System-MIB

File: Unisphere-Data-ERX-System-MIB.mib (70543 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
IF-MIB Unisphere-Data-MIBs Unisphere-Data-TC

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Integer32 Unsigned32 TimeTicks
TEXTUAL-CONVENTION DisplayString TruthValue
DateAndTime MODULE-COMPLIANCE OBJECT-GROUP
NOTIFICATION-GROUP InterfaceIndexOrZero usDataMibs
UsdEnable

Defined Types

UsdTimingSelector  
The system timing selector. A value of 1 corresponds to the primary timing selector. A value of 2 corresponds to the secondary timing selector. A value of 3 corresponds to the tertiary timing selector. A value of 4 indicates an error with the timing selector.
TEXTUAL-CONVENTION    
  INTEGER 1..4  

UsdTimingSourceType  
The set of selectable timing source types. The timing source type determines the timing source parameters.
TEXTUAL-CONVENTION    
  INTEGER timingInterfaceIfIndex(1), timingInternal(2), timingLine(3)  

UsdTimingSourceLineType  
The set of choices for line type timing.
TEXTUAL-CONVENTION    
  INTEGER timingSourceLineUndefined(0), timingSourceLineE1PortA(1), timingSourceLineE1PortB(2), timingSourceLineT1PortA(3), timingSourceLineT1PortB(4)  

UsdSysCardType  
The type of card in a system slot: unknown Unknown type. srp Switch/Route Processor. ct3 Channelized T3. oc3 OC-3 (SONET/SDH). ut3Atm Unchannelized T3 (ATM service). ut3Frame Unchannelized T3 (Frame service). ue3Atm Unchannelized E3 (ATM service). ue3Frame Uncahnnelized E3 (Frame service). ce1 Channelized E1. ct1 Channelized T1. dpfe Dual Port Fast Ethernet. oc12Pos OC-12 (POS/SDH). oc12Atm OC-12 (ATM service). oc3Pos Quad OC-3 (POS/SDH). oc3Atm Quad OC-3 (ATM service). ge Gigabit Ethernet. fe8 Fast Ethernet 8-port. oc3oc12Pos Generic OC3/OC12 POS (multi-personality). oc3oc12Atm Generic OC3/OC12 ATM (multi-personality). coc3oc12 Channelized generic OC3/OC12 (multi-personality). coc3 Channelized OC3. coc12 Channelized OC12. oc12Server OC-12 Rate Server Card. hssi High Speed Serial Interface. geFe Generic GE/FE (multi-personality). ct3P12 Channelized T3 12-port. v35 X.21/V.35 Card. ut3f12 Unchannelized T3 12-port. ue3f12 Unchannelized E3 12-port. coc3F3 OC-3 channelized to T3. coc12F3 OC-12 channelized to T3. cocxF3 12-port T3/E3 or OC3/OC12 (multi-personality).
TEXTUAL-CONVENTION    
  INTEGER unknown(0), srp(1), ct3(2), oc3(3), ut3Atm(4), ut3Frame(5), ue3Atm(6), ue3Frame(7), ce1(8), ct1(9), dpfe(10), oc12Pos(11), oc12Atm(12), oc3Pos(13), oc3Atm(14), ge(15), fe8(16), oc3oc12Pos(17), oc3oc12Atm(18), coc3oc12(19), coc3(20), coc12(21), oc12Server(22), hssi(23), geFe(24), ct3P12(25), v35(26), ut3f12(27), ue3f12(28), coc12F3(29), coc3F3(30), cocxF3(31)  

UsdERXSysTimingSelectorEntry  
SEQUENCE    
  usdERXSysTimingSelectorIndex UsdTimingSelector
  usdERXSysTimingSourceType UsdTimingSourceType
  usdERXSysTimingSourceIfIndex InterfaceIndexOrZero
  usdERXSysTimingSourceLine UsdTimingSourceLineType
  usdERXSysTimingStatus INTEGER

UsdERXSysSlotEntry  
SEQUENCE    
  usdERXSysSlotIndex Integer32
  usdERXSysSlotDescr DisplayString
  usdERXSysSlotCurrentCardType UsdSysCardType
  usdERXSysSlotRev Integer32
  usdERXSysSlotAdminStatus UsdEnable
  usdERXSysSlotOperStatus INTEGER
  usdERXSysSlotDisableReason INTEGER
  usdERXSysSlotExpectedCardType UsdSysCardType
  usdERXSysSlotControl INTEGER
  usdERXSysSlotCpuUtilPct Integer32
  usdERXSysSlotMemUtilPct Integer32
  usdERXSysSlotIoaPresent TruthValue
  usdERXSysSlotPortCount Integer32
  usdERXSysSlotLastChange TimeTicks
  usdERXSysSlotRedundancyLockout UsdEnable
  usdERXSysSlotRedundancyGroupId Unsigned32
  usdERXSysSlotSpareServer TruthValue
  usdERXSysSlotAssociatedSlot Integer32
  usdERXSysSlotRevertControl INTEGER
  usdERXSysSlotRedundancyRevertTime DateAndTime
  usdERXSysSlotBootReleaseFile DisplayString
  usdERXSysSlotBootBackupReleaseFile DisplayString
  usdERXSysSlotSerialNumber DisplayString
  usdERXSysSlotAssemblyPartNumber DisplayString
  usdERXSysSlotAssemblyRev DisplayString
  usdERXSysSlotIoaSerialNumber DisplayString
  usdERXSysSlotIoaAssemblyPartNumber DisplayString
  usdERXSysSlotIoaAssemblyRev DisplayString

UsdERXSysPortEntry  
SEQUENCE    
  usdERXSysPortIndex Integer32
  usdERXSysPortDescr DisplayString
  usdERXSysPortType INTEGER
  usdERXSysPortIfIndex InterfaceIndexOrZero

UsdERXSysPowerEntry  
SEQUENCE    
  usdERXSysPowerIndex Integer32
  usdERXSysPowerDescr DisplayString
  usdERXSysPowerStatus INTEGER

UsdERXSysTempEntry  
SEQUENCE    
  usdERXSysTempIndex Integer32
  usdERXSysTempDescr DisplayString
  usdERXSysTempStatus INTEGER
  usdERXSysTempValue Integer32

UsdERXSysSubsystemEntry  
SEQUENCE    
  usdERXSysSubsystemIndex Integer32
  usdERXSysSubsystemName DisplayString
  usdERXSysSubsystemControl INTEGER
  usdERXSysSubsystemBootReleaseFile DisplayString
  usdERXSysSubsystemBootBackupReleaseFile DisplayString

Defined Values

usdERXSysMIB 1.3.6.1.4.1.4874.2.2.17
MIB objects for managing ERX Edge Router systems.
MODULE-IDENTITY    

usdERXSysTrap 1.3.6.1.4.1.4874.2.2.17.0
OBJECT IDENTIFIER    

usdERXSysObjects 1.3.6.1.4.1.4874.2.2.17.1
OBJECT IDENTIFIER    

usdERXSysConformance 1.3.6.1.4.1.4874.2.2.17.2
OBJECT IDENTIFIER    

usdERXSysGeneral 1.3.6.1.4.1.4874.2.2.17.1.1
OBJECT IDENTIFIER    

usdERXSysFabric 1.3.6.1.4.1.4874.2.2.17.1.2
OBJECT IDENTIFIER    

usdERXSysNvs 1.3.6.1.4.1.4874.2.2.17.1.3
OBJECT IDENTIFIER    

usdERXSysSlot 1.3.6.1.4.1.4874.2.2.17.1.4
OBJECT IDENTIFIER    

usdERXSysPort 1.3.6.1.4.1.4874.2.2.17.1.5
OBJECT IDENTIFIER    

usdERXSysPower 1.3.6.1.4.1.4874.2.2.17.1.6
OBJECT IDENTIFIER    

usdERXSysTemperature 1.3.6.1.4.1.4874.2.2.17.1.7
OBJECT IDENTIFIER    

usdERXSysSubsystem 1.3.6.1.4.1.4874.2.2.17.1.8
OBJECT IDENTIFIER    

usdERXSysChassisRev 1.3.6.1.4.1.4874.2.2.17.1.1.1
Chassis revision number. If unknown, the value 255 is reported.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

usdERXSysSwVersion 1.3.6.1.4.1.4874.2.2.17.1.1.2
Currently executing operational software version.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

usdERXSysSwBuildDate 1.3.6.1.4.1.4874.2.2.17.1.1.3
Build date of currently executing operational software version.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

usdERXSysRevertControl 1.3.6.1.4.1.4874.2.2.17.1.1.4
Global revert control: off Disable global revert. immediate All slots are to revert immediately (asap). timeOfDay All slots are to revert at time specified by usdRxSysRevertTimeOfDay. This object/value must be set concurrently with usdERXSysRevertTimeOfDay.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), immediate(1), timeOfDay(2)  

usdERXSysRevertTimeOfDay 1.3.6.1.4.1.4874.2.2.17.1.1.5
The number of seconds past midnight on any given day at which time reverts are allowed to occur. This object must be set concurrently with usdERXSysRevertControl.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..86399  

usdERXSysBootConfigControl 1.3.6.1.4.1.4874.2.2.17.1.1.6
System boot configuration control: file Revert to configuration settings specified by usdERXSysBootConfigFile. The usdERXSysBootConfigControl and usdERXSysBootConfigFile must be specified together in the same set request PDU. fileOnce Revert to configuration settings specified by usdERXSysBootConfigFile. Do not continue to use file after using it once. The usdERXSysBootConfigControl and usdERXSysBootConfigFile must be specified together in the same set request PDU. factoryDefaults Revert to factory default settings. runningConfiguration Revert to current settings.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER file(0), fileOnce(1), factoryDefaults(2), runningConfiguration(3)  

usdERXSysBootBackupConfigControl 1.3.6.1.4.1.4874.2.2.17.1.1.7
System boot backup configuration control: file Revert to backup configuration settings specified by usdERXSysBootBackupConfigFile. The usdERXSysBootBackupConfigControl and usdERXSysBootBackupConfigFile must be specified together in the same set request PDU. factoryDefaults Revert to factory default settings. none Specify no backup.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER file(0), factoryDefaults(1), none(2)  

usdERXSysBootForceBackupControl 1.3.6.1.4.1.4874.2.2.17.1.1.8
System boot force backup control: off Do not force revert to backup settings. on Do force revert to backup settings.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1)  

usdERXSysBootAutoRevertControl 1.3.6.1.4.1.4874.2.2.17.1.1.9
System boot auto revert control: default Use default auto-revert tolerances. never Never auto-revert to backup. set Set auto-revert settings at specified tolerances.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER default(0), never(1), set(2)  

usdERXSysBootAutoRevertCountTolerance 1.3.6.1.4.1.4874.2.2.17.1.1.10
The auto-revert reboot count tolerance. This object cannot be set to zero, but may contain a zero value when the control is set to never(1).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..4294967294  

usdERXSysBootAutoRevertTimeTolerance 1.3.6.1.4.1.4874.2.2.17.1.1.11
The auto-revert reboot time tolerance. This object cannot be set to zero, but will contain a zero value when the control is set to never(1).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..4294967294  

usdERXSysBootReleaseFile 1.3.6.1.4.1.4874.2.2.17.1.1.12
The local boot release file name, with extension .rel.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

usdERXSysBootConfigFile 1.3.6.1.4.1.4874.2.2.17.1.1.13
The local boot configuration file name, with extension .cnf. The usdERXSysBootConfigControl and usdERXSysBootConfigFile must be specified together in the same set request PDU.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

usdERXSysBootBackupReleaseFile 1.3.6.1.4.1.4874.2.2.17.1.1.14
The local backup boot release file name, with extension .rel.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

usdERXSysBootBackupConfigFile 1.3.6.1.4.1.4874.2.2.17.1.1.15
The local backup boot configuration file name, with extension .cnf. The usdERXSysBootBackupConfigControl and usdERXSysBootBackupConfigFile must be specified together in the same set request PDU.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

usdERXSysAdminTimingSource 1.3.6.1.4.1.4874.2.2.17.1.1.16
The administrative timing source for the ERX system. The ERX periodically monitors the status of three timing sources, primary, secondary and tertiary. If the systems current timing source fails, the system will automatically downgrade to the next timing source. If the system is configured to automatically upgrade (usdERXSysTimingDisableAutoUpgrade is set to false(2)) the system will switch back to the higher timing source when it becomes available. A timing source failure can be detected by comparing the operational and admin timing sources. If they are not equal, the system has swapped timing sources because the administratively set value is in the error state.
Status: current Access: read-write
OBJECT-TYPE    
  UsdTimingSelector  

usdERXSysOperTimingSource 1.3.6.1.4.1.4874.2.2.17.1.1.17
The operations timing source for the ERX system. The ERX periodically monitors the status of three timing sources, primary, secondary and tertiary. If the systems current timing source fails, the system will automatically downgrade to the next timing source. If the system is configured to automatically upgrade (usdERXSysTimingDisableAutoUpgrade is set to false(2)) the system will switch back to the higher timing source when it becomes available.
Status: current Access: read-only
OBJECT-TYPE    
  UsdTimingSelector  

usdERXSysTimingDisableAutoUpgrade 1.3.6.1.4.1.4874.2.2.17.1.1.18
This object controls the automatic timing selector upgrade. Setting this object to true(1) will prevent automatic upgrade to the next highest timing selector. Setting this object to false(2) will enable the automatic upgrade of timing selectors.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

usdERXSysTimingSelectorTable 1.3.6.1.4.1.4874.2.2.17.1.1.19
Table of system timing selectors.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UsdERXSysTimingSelectorEntry

usdERXSysTimingSelectorEntry 1.3.6.1.4.1.4874.2.2.17.1.1.19.1
A table entry describing a system timing selector.
Status: current Access: not-accessible
OBJECT-TYPE    
  UsdERXSysTimingSelectorEntry  

usdERXSysTimingSelectorIndex 1.3.6.1.4.1.4874.2.2.17.1.1.19.1.1
The system timing selector index associated with this entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  UsdTimingSelector  

usdERXSysTimingSourceType 1.3.6.1.4.1.4874.2.2.17.1.1.19.1.2
The system timing source type for this entry. This object must be present when setting either the usdERXSysTimingSourceIfIndex or usdERXSysTimingSourceLine objects. Also, if the value of this object is set to timingInternal(2), no other objects should be simultanously set, otherwise the agent will return an error.
Status: current Access: read-write
OBJECT-TYPE    
  UsdTimingSourceType  

usdERXSysTimingSourceIfIndex 1.3.6.1.4.1.4874.2.2.17.1.1.19.1.3
The ifIndex of the interface selected as the system timing source. The usdERXSysTimingSourceType object must be set to timingInterfaceIfIndex(1) otherwise setting this object will fail.
Status: current Access: read-write
OBJECT-TYPE    
  InterfaceIndexOrZero  

usdERXSysTimingSourceLine 1.3.6.1.4.1.4874.2.2.17.1.1.19.1.4
The line type timing source for this entry. The usdRxSysTimingSourceType object must be set to timingLine(3) for the agent to accept a set to this object.
Status: current Access: read-write
OBJECT-TYPE    
  UsdTimingSourceLineType  

usdERXSysTimingStatus 1.3.6.1.4.1.4874.2.2.17.1.1.19.1.5
The status associated with this system timing selector.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER timingStatusOk(1), timingStatusError(2), timingStatusUnknown(3)  

usdERXSysMemUtilPct 1.3.6.1.4.1.4874.2.2.17.1.1.20
Percentage of system memory utilization. A value of -1 indicates the utilization is unknown.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..100  

usdERXSysMemCapacity 1.3.6.1.4.1.4874.2.2.17.1.1.21
The total memory capacity of the system.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usdERXSysHighMemUtilThreshold 1.3.6.1.4.1.4874.2.2.17.1.1.22
The value of system memory utilization, where if reached for the first time will generate a high memory utilization event to the management entity on this system. The value of this object must be greated than the value of usdERXSysAbatedMemUtilThreshold.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..100  

usdERXSysAbatedMemUtilThreshold 1.3.6.1.4.1.4874.2.2.17.1.1.23
The value of system memory utilization that is used to determine when to generate an abated memory utilization event notification to the management entity on this system. The value of this object must be less than the value of usdERXSysHighMemUtilThreshold. The abated memory utilization trap is sent once if the high memory threshold was reached, and memory utilization falls to the value of this object.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..99  

usdERXSysMemUtilTrapEnable 1.3.6.1.4.1.4874.2.2.17.1.1.24
Controls the sending of system memory utilization events. Setting the value of this object to true(1) will cause system memory utilization event notification, if they occur, to be sent to the management entity on this system. Setting the value of this object to false(2) will disable event notifications.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

usdERXSysFabricSpeed 1.3.6.1.4.1.4874.2.2.17.1.2.1
Speed of switching fabric, in gigabits per second.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usdERXSysFabricRev 1.3.6.1.4.1.4874.2.2.17.1.2.2
Fabric revision number. If unknown, the value 255 is reported.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

usdERXSysNvsStatus 1.3.6.1.4.1.4874.2.2.17.1.3.1
Status of non-volatile storage (NVS): notPresent NVS is not installed. writeProtected NVS is write-protected. volumeError Status poll of NVS failed. nearCapacity Utilization exceeds 85% of NVS capacity. ok NVS is operational, none of the preceding conditions apply. nearConfigCapacity Utilization exceeds the ability to save the running configuration.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notPresent(0), writeProtected(1), volumeError(2), nearCapacity(3), ok(4), nearConfigCapacity(5)  

usdERXSysNvsCapacity 1.3.6.1.4.1.4874.2.2.17.1.3.2
Capacity of NVS storage in megabytes.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usdERXSysNvsUtilPct 1.3.6.1.4.1.4874.2.2.17.1.3.3
Percentage of NVS storage used. A value of -1 indicates NVS utilization is unknown.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..100  

usdERXSysSlotCount 1.3.6.1.4.1.4874.2.2.17.1.4.1
The number of slots in the system.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usdERXSysSlotTable 1.3.6.1.4.1.4874.2.2.17.1.4.2
Table of system slots.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UsdERXSysSlotEntry

usdERXSysSlotEntry 1.3.6.1.4.1.4874.2.2.17.1.4.2.1
A table entry describing contents of a system slot.
Status: current Access: not-accessible
OBJECT-TYPE    
  UsdERXSysSlotEntry  

usdERXSysSlotIndex 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.1
Slot number. NOTE: Slot numbers are zero-based.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..255  

usdERXSysSlotDescr 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.2
Textual description of the card.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..63)  

usdERXSysSlotCurrentCardType 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.3
Type of card actually in the slot. This could be different from the type reported in usdERXSysSlotExpectedCardType, in which case it may be necessary to set usdERXSysSlotControl to 'flush' before this card can be made operational.
Status: current Access: read-only
OBJECT-TYPE    
  UsdSysCardType  

usdERXSysSlotRev 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.4
Revision number of the card. If unknown, the value 255 is reported.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

usdERXSysSlotAdminStatus 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.5
Exerts administrative control to enable/disable the slot.
Status: current Access: read-write
OBJECT-TYPE    
  UsdEnable  

usdERXSysSlotOperStatus 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.6
Status of the card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), empty(1), disabled(2), failed(3), booting(4), initializing(5), online(6), standby(7), inactive(8)  

usdERXSysSlotDisableReason 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.7
Indicates the condition causing the slot to be disabled: none Value when card is not disabled. unknown Unknown reason for disablement. assessing The slot content is being assessed (transient initialization state). admin The slot is administratively disabled. cardMismatch The current card type conflicts with configuration associated with a different card type that previously occupied the slot. fabricLimit Card resource requirements exceed available fabric capacity. imageError Software image for card is missing or invalid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), unknown(1), assessing(2), admin(3), cardMismatch(4), fabricLimit(5), imageError(6)  

usdERXSysSlotExpectedCardType 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.8
Type of card associated with this slot through prior presence. After the card is removed, this association persists (and inhibits operation of a different card type in this slot, if one is inserted) until usdERXSysSlotControl is set to 'flush'.
Status: current Access: read-only
OBJECT-TYPE    
  UsdSysCardType  

usdERXSysSlotControl 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.9
Administrative control of this slot: noOperation Setting this value has no effect. flush Flushes configuration associated with a card type that previously occupied this slot. Used to explicitly confirm that the slot is now empty, or contains a different card type. Card must be disabled when this value is asserted. See description for usdERXSysSlotDisableReason. reset Resets the slot. forceFailover Forces the slot to failover to backup. noBoot Deconfigure primary release file for the slot. noBootBackup Deconfigure backup release file for the slot.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noOperation(0), flush(1), reset(2), forceFailover(3), noBoot(4), noBootBackup(5)  

usdERXSysSlotCpuUtilPct 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.10
Percentage of CPU utilization. A value of -1 indicates the utilization is unknown.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..100  

usdERXSysSlotMemUtilPct 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.11
Percentage of memory utilization. A value of -1 indicates the utilization is unknown.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..100  

usdERXSysSlotIoaPresent 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.12
Indicates whether the card's corresponding I/O adapter is present.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

usdERXSysSlotPortCount 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.13
Number of physical ports for the EXPECTED card type for this slot. NOTE: In event of a card mismatch in this slot, the port count for the CURRENT card in this slot is not recognized/reported until the configuration for the EXPECTED card is explicitly flushed via usdERXSysSlotControl.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usdERXSysSlotLastChange 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.14
The value of sysUpTime when the value of usdERXSysSlotOperStatus last changed.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

usdERXSysSlotRedundancyLockout 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.15
Exerts administrative control to enable/disable Redundancy protection for the slot.
Status: current Access: read-write
OBJECT-TYPE    
  UsdEnable  

usdERXSysSlotRedundancyGroupId 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.16
Identifies the Redundancy group as derived from hardware settings.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

usdERXSysSlotSpareServer 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.17
True only if the line card in slot is a spare redundant server.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

usdERXSysSlotAssociatedSlot 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.18
If the module is a primary card and the spare is acting on its behalf, then the value of this object is the slot number of the associated spare. If the module is a primary card and is active (not spared), then the value of this object is the cards actual slot number. If the module is a spare card and it is active, then the value of this object is the slot number of the primary card that is being spared for. If the module is a spare and it is inactive, then the value of this object is the its own slot number. If module is not part of a redundancy group, or the slot is empty, the value of this object is 255.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usdERXSysSlotRevertControl 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.19
Per-slot revert control: off Disable slot revert. immediate Slot is to revert immediately (asap). timeAndDate Slot is to revert at time specified by usdRxSysSlotRedundancyRevertTime.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), immediate(1), timeAndDate(2)  

usdERXSysSlotRedundancyRevertTime 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.20
The date and time associated with the timeAndDate (delayed) revert operation.
Status: current Access: read-write
OBJECT-TYPE    
  DateAndTime  

usdERXSysSlotBootReleaseFile 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.21
The local boot release file name for this slot, with extension .rel.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

usdERXSysSlotBootBackupReleaseFile 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.22
The local backup boot release file name for this slot, with extension .rel.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

usdERXSysSlotSerialNumber 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.23
The serial number of the card in this slot.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

usdERXSysSlotAssemblyPartNumber 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.24
The part number of the card in this slot.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

usdERXSysSlotAssemblyRev 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.25
The revision number of the card assembly in this slot.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..3)  

usdERXSysSlotIoaSerialNumber 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.26
The serial number of the I/O adaptor on the card in this slot.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

usdERXSysSlotIoaAssemblyPartNumber 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.27
The part number of the I/O adaptor on the card in this slot.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

usdERXSysSlotIoaAssemblyRev 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.28
The revision number of the I/O adaptor assembly on the card in this slot.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..3)  

usdERXSysPortTable 1.3.6.1.4.1.4874.2.2.17.1.5.1
Table of system physical ports. The information in this table reflects the ports for the EXPECTED card type in each slot; in event of a card mismatch, this table permits navigation of the existing configuration of the expected card type.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UsdERXSysPortEntry

usdERXSysPortEntry 1.3.6.1.4.1.4874.2.2.17.1.5.1.1
A table entry describing a physical port of the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  UsdERXSysPortEntry  

usdERXSysPortIndex 1.3.6.1.4.1.4874.2.2.17.1.5.1.1.1
Port number of this physical port, relative to the slot in which it resides. Each physical port is uniquely distinguished by its slot/port pair. NOTE: Port numbers are zero-based.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..255  

usdERXSysPortDescr 1.3.6.1.4.1.4874.2.2.17.1.5.1.1.2
Textual description of this port.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..63)  

usdERXSysPortType 1.3.6.1.4.1.4874.2.2.17.1.5.1.1.3
Type of the physical port: unknown Unknown port type. eth Ethernet. ct3 Channelized T3. oc3c OC-3c (SONET/SDH). ut3Atm Unchannelized T3 (ATM service). ut3Frame Unchannelized T3 (Frame service). ue3Atm Unchannelized E3 (ATM service). ue3Frame Unchannelized E3 (Frame service). ce1 Channelized E1. ct1 Channelized T1. oc12Pos OC-12 (POS/SDH). oc12Atm OC-12 (ATM service). oc3Pos OC-3 (POS/SDH). oc3Atm OC-3 (ATM service). coc3 Channelized OC-3. coc12 Channelized OC-12. oc12Server OC-12 (Server card). hssi High Speed Serial Interface. v35 X.21/V.35.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), eth(1), ct3(2), oc3c(3), ut3Atm(4), ut3Frame(5), ue3Atm(6), ue3Frame(7), ce1(8), ct1(9), oc12cPos(10), oc12cAtm(11), oc3cPos(12), oc3cAtm(13), coc3(14), coc12(15), oc12Server(16), hssi(17), v35(18)  

usdERXSysPortIfIndex 1.3.6.1.4.1.4874.2.2.17.1.5.1.1.4
The ifIndex of the Interfaces MIB ifTable entry corresponding to this physical port; if zero, the ifIndex is unknown or does not exist.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndexOrZero  

usdERXSysPowerTable 1.3.6.1.4.1.4874.2.2.17.1.6.1
Table of system power elements.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UsdERXSysPowerEntry

usdERXSysPowerEntry 1.3.6.1.4.1.4874.2.2.17.1.6.1.1
A table entry describing status of a system power element.
Status: current Access: not-accessible
OBJECT-TYPE    
  UsdERXSysPowerEntry  

usdERXSysPowerIndex 1.3.6.1.4.1.4874.2.2.17.1.6.1.1.1
Arbitrary integer index to distinguish entries in this table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..255  

usdERXSysPowerDescr 1.3.6.1.4.1.4874.2.2.17.1.6.1.1.2
Textual description of this power element.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..63)  

usdERXSysPowerStatus 1.3.6.1.4.1.4874.2.2.17.1.6.1.1.3
The status of the power element: inactive No power available from this element. active Power available from this element.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inactive(0), active(1)  

usdERXSysTempFanStatus 1.3.6.1.4.1.4874.2.2.17.1.7.1
Status of fan subsystem. ok All components operational warning The fan subsystem has a non-critical failure. failed The fan subsystem has a critical failure, or has been removed, and is now non-operational.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER failed(0), ok(1), warning(2)  

usdERXSysTempTable 1.3.6.1.4.1.4874.2.2.17.1.7.2
Table of system temperature sensors. Sensors are distributed across the chassis, at least one sensor per populated slot.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UsdERXSysTempEntry

usdERXSysTempEntry 1.3.6.1.4.1.4874.2.2.17.1.7.2.1
A table entry describing status of a temperature sensor.
Status: current Access: not-accessible
OBJECT-TYPE    
  UsdERXSysTempEntry  

usdERXSysTempIndex 1.3.6.1.4.1.4874.2.2.17.1.7.2.1.1
Arbitrary integer index to distinguish sensors associated with the same chassis slot.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..255  

usdERXSysTempDescr 1.3.6.1.4.1.4874.2.2.17.1.7.2.1.2
Textual description of this sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..63)  

usdERXSysTempStatus 1.3.6.1.4.1.4874.2.2.17.1.7.2.1.3
The status of a temperature sensor: unknown unknown failed failed tooLow below nominal range nominal within nominal range tooHigh above nominal range tooLowWarning near lower limit tooHighWarning near upper limit
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), failed(1), tooLow(2), nominal(3), tooHigh(4), tooLowWarning(5), tooHighWarning(6)  

usdERXSysTempValue 1.3.6.1.4.1.4874.2.2.17.1.7.2.1.4
The temperature measured by this sensor in degrees Celsius. This measurement is valid only if the value of the corresponding usdERXSysTempStatus is nominal.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

usdERXSysTempProtectionStatus 1.3.6.1.4.1.4874.2.2.17.1.7.3
Thermal protection status: monitoring monitoring inHoldOff hold off time has begun activatedHoldOffExpired hold off time has expired, the system is in thermal protection mode activatedTempTooHigh temperature too high, the system is in thermal protection mode
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER monitoring(1), inHoldOff(2), activatedHoldOffExpired(3), activatedTempTooHigh(4)  

usdERXSysTempProtectionHoldOffTime 1.3.6.1.4.1.4874.2.2.17.1.7.4
The time, in seconds, before the system enters thermal protection mode after a critical fan subsystem failure is detected.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..1200  

usdERXSysTempProtectionHoldOffTimeRemaining 1.3.6.1.4.1.4874.2.2.17.1.7.5
The time remaining, in seconds, before the system enters thermal protection mode while the thermal protection status is set to inHoldOff. The value decrements every second until it reaches zero, and the status changes to activatedHoldOffExpired. When the thermal protection status is not inHoldOff or activatedHoldOffExpired, the value is set to the hold off time.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..1200  

usdERXSysSubsystemTable 1.3.6.1.4.1.4874.2.2.17.1.8.1
Table of subsystems.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UsdERXSysSubsystemEntry

usdERXSysSubsystemEntry 1.3.6.1.4.1.4874.2.2.17.1.8.1.1
A table entry containing information pertaining to a subsystem.
Status: current Access: not-accessible
OBJECT-TYPE    
  UsdERXSysSubsystemEntry  

usdERXSysSubsystemIndex 1.3.6.1.4.1.4874.2.2.17.1.8.1.1.1
Subsystem number.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..255  

usdERXSysSubsystemName 1.3.6.1.4.1.4874.2.2.17.1.8.1.1.2
The name of the subsystem.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..128)  

usdERXSysSubsystemControl 1.3.6.1.4.1.4874.2.2.17.1.8.1.1.3
Administrative control of this subsystem: noOperation Setting this value has no effect. noBoot Deconfigure primary release file for the subsystem. noBootBackup Deconfigure backup release file for the subsystem.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noOperation(0), noBoot(1), noBootBackup(2)  

usdERXSysSubsystemBootReleaseFile 1.3.6.1.4.1.4874.2.2.17.1.8.1.1.4
The local boot release file name for this subsystem, with extension .rel.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

usdERXSysSubsystemBootBackupReleaseFile 1.3.6.1.4.1.4874.2.2.17.1.8.1.1.5
The local backup boot release file name for this subsystem, with extension .rel.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

usdERXSysSlotOperStatusChange 1.3.6.1.4.1.4874.2.2.17.0.1
Reports a status change for a slot. This trap is generated on a transition into a stable state (online or disabled) or on a transition out of online.
Status: current Access: read-write
NOTIFICATION-TYPE    

usdERXSysPowerStatusChange 1.3.6.1.4.1.4874.2.2.17.0.2
Reports a change in the status of a power element.
Status: current Access: read-write
NOTIFICATION-TYPE    

usdERXSysTempFanStatusChange 1.3.6.1.4.1.4874.2.2.17.0.3
Reports a transition between the three states of the fan subsystem. When the fan subsystem transitions to the failed state the thermal protection hold off time begins.
Status: current Access: read-write
NOTIFICATION-TYPE    

usdERXSysTempStatusChange 1.3.6.1.4.1.4874.2.2.17.0.4
Reports a change in the temperature status. When the status transitions to the tooHigh state the system enters thermal protection mode.
Status: current Access: read-write
NOTIFICATION-TYPE    

usdERXSysHighMemUtil 1.3.6.1.4.1.4874.2.2.17.0.5
Report system memory utilization has met the conditions of usdERXSysHighMemUtilThreshold.
Status: current Access: read-write
NOTIFICATION-TYPE    

usdERXSysAbatedMemUtil 1.3.6.1.4.1.4874.2.2.17.0.6
Reports system memory utilization has met the conditions of usdERXSysAbatedMemUtilThreshold.
Status: current Access: read-write
NOTIFICATION-TYPE    

usdERXSysTempProtectionStatusChange 1.3.6.1.4.1.4874.2.2.17.0.7
Notification about changes in the state of Thermal Protection. This notification is sent when the tempProtectionStatus changes. It is also sent when the holdOffTimeRemaining is 50% of the holdOffTime.
Status: current Access: read-write
NOTIFICATION-TYPE    

usdERXSysCompliances 1.3.6.1.4.1.4874.2.2.17.2.1
OBJECT IDENTIFIER    

usdERXSysGroups 1.3.6.1.4.1.4874.2.2.17.2.2
OBJECT IDENTIFIER    

usdERXSysCompliance 1.3.6.1.4.1.4874.2.2.17.2.1.1
Obsolete compliance statement for entities which implement the ERX System MIB. This compliance statement became obsolete when new slot information objects were added.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

usdERXSysCompliance1 1.3.6.1.4.1.4874.2.2.17.2.1.2
Obsolete compliance statement for entities which implement the ERX System MIB. This compliance statement became obsolete when the timing group was added.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

usdERXSysCompliance2 1.3.6.1.4.1.4874.2.2.17.2.1.3
Obsolete compliance statement for entities which implement the ERX System MIB. This compliance statement became obsolete when new memory information objects and notifications were added.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

usdERXSysCompliance3 1.3.6.1.4.1.4874.2.2.17.2.1.4
Obsolete compliance statement for entities which implement the ERX System MIB. This compliance statement became obsolete when new system temperature information objects and notifications were added.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

usdERXSysCompliance4 1.3.6.1.4.1.4874.2.2.17.2.1.5
The compliance statement for entities which implement the ERX System MIB.
Status: current Access: read-write
MODULE-COMPLIANCE    

usdERXSysGroup 1.3.6.1.4.1.4874.2.2.17.2.2.1
Obsolete collection of management objects pertaining to system capabilities in a Juniper product. This group became obsolete when new slot information objects were added.
Status: obsolete Access: read-write
OBJECT-GROUP    

usdERXSysNotifyGroup 1.3.6.1.4.1.4874.2.2.17.2.2.2
Obsolete collection of management notifications pertaining to system operations in a Juniper product. This group became obsolete when new memory threshold notificaitons were added.
Status: obsolete Access: read-write
NOTIFICATION-GROUP    

usdERXSysGeneralGroup 1.3.6.1.4.1.4874.2.2.17.2.2.3
Obsolete collection of management objects pertaining to general system capabilities in a Juniper product. This group became obsolete when new memory management objects were added.
Status: obsolete Access: read-write
OBJECT-GROUP    

usdERXSysFabricGroup 1.3.6.1.4.1.4874.2.2.17.2.2.4
A collection of management objects pertaining to system fabric capabilities in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

usdERXSysNvsGroup 1.3.6.1.4.1.4874.2.2.17.2.2.5
A collection of management objects pertaining to non-volitile storage subsystem capabilities in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

usdERXSysSlotGroup 1.3.6.1.4.1.4874.2.2.17.2.2.6
A collection of management objects pertaining to slot-specific system capabilities in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

usdERXSysPortGroup 1.3.6.1.4.1.4874.2.2.17.2.2.7
A collection of management objects pertaining to port-related system capabilities in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

usdERXSysPowerGroup 1.3.6.1.4.1.4874.2.2.17.2.2.8
A collection of management objects pertaining to the power subsystem capabilities in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

usdERXSysTemperatureGroup 1.3.6.1.4.1.4874.2.2.17.2.2.9
Obsolete collection of management objects pertaining to system temperature monitoring capabilities in a Juniper product. This group became obsolete when temperature shutdown parameters were added.
Status: obsolete Access: read-write
OBJECT-GROUP    

usdERXSysSubsystemGroup 1.3.6.1.4.1.4874.2.2.17.2.2.10
A collection of management objects pertaining to subsystem capabilities in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

usdERXSysTimingGroup 1.3.6.1.4.1.4874.2.2.17.2.2.11
A collection of management objects pertaining to system timing capabilities in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

usdERXSysGeneralGroup2 1.3.6.1.4.1.4874.2.2.17.2.2.12
A collection of management objects pertaining to general system capabilities in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

usdERXSysNotifyGroup2 1.3.6.1.4.1.4874.2.2.17.2.2.13
Obsolete collection of management notifications pertaining to system operations in a Juniper product. This group became obsolete when the tempProtectionStatusChange notification was added.
Status: obsolete Access: read-write
NOTIFICATION-GROUP    

usdERXSysTemperatureGroup2 1.3.6.1.4.1.4874.2.2.17.2.2.14
A collection of management objects pertaining to system temperature monitoring capabilities in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

usdERXSysNotifyGroup3 1.3.6.1.4.1.4874.2.2.17.2.2.15
A collection of management notifications pertaining to system operations in a Juniper product.
Status: current Access: read-write
NOTIFICATION-GROUP