TELESTE-LUMINATO-MIB

File: TELESTE-LUMINATO-MIB.mib (87883 bytes)

Imported modules

RFC-1212 RFC1155-SMI RFC1213-MIB
SNMPv2-SMI TELESTE-ROOT-MIB UCD-SNMP-MIB

Imported symbols

OBJECT-TYPE TimeTicks DisplayString
Unsigned32 Counter32 luminato
Float

Defined Types

InterfaceTypeEntry  
SEQUENCE    
  interfaceTypeId INTEGER

StatusCodeDeviceEntry  
SEQUENCE    
  scdObjectId Unsigned32
  scdObjectValue INTEGER
  scdObjectDescriptor DisplayString
  scdObjectAlarmValue INTEGER

StatusCodeModuleEntry  
SEQUENCE    
  scmModuleId INTEGER
  scmObjectId Unsigned32
  scmObjectValue INTEGER
  scmObjectDescriptor DisplayString
  scmObjectAlarmValue INTEGER

StatusCodeInterfaceEntry  
SEQUENCE    
  sciInterfaceId INTEGER
  sciObjectId Unsigned32
  sciObjectValue INTEGER
  sciObjectDescriptor DisplayString
  sciObjectAlarmValue INTEGER

StatusCodeTransportStreamEntry  
SEQUENCE    
  sctsTransportStreamId INTEGER
  sctsObjectId Unsigned32
  sctsObjectValue INTEGER
  sctsObjectDescriptor DisplayString
  sctsObjectAlarmValue INTEGER

StatusCodeServiceEntry  
SEQUENCE    
  scsSID INTEGER
  scsObjectId Unsigned32
  scsObjectValue INTEGER
  scsObjectDescriptor DisplayString
  scsServiceName DisplayString
  scsObjectAlarmValue INTEGER

StatusCodePidEntry  
SEQUENCE    
  scpPID INTEGER
  scpObjectId Unsigned32
  scpObjectValue INTEGER
  scpObjectDescriptor DisplayString
  scpObjectAlarmValue INTEGER

IfExtEntry  
SEQUENCE    
  ifExtIndex INTEGER
  ifExtName DisplayString
  ifExtModule INTEGER
  ifExtPhysInterface INTEGER
  ifExtLogiInterface INTEGER
  ifExtDirection INTEGER

SignalPhysEntry  
SEQUENCE    
  signalSnr INTEGER
  signalSnrMin INTEGER
  signalSnrMax INTEGER
  signalCcErrors INTEGER
  signalBer Float
  signalVber Float

TransferEntry  
SEQUENCE    
  transBitrate INTEGER
  transBitrateMin INTEGER
  transBitrateMax INTEGER

ProMpegFecEntry  
SEQUENCE    
  fecValidPkts Counter32
  fecUncorrectedPkts Counter32
  fecCorrectedPkts Counter32
  fecDuplicatePkts Counter32
  fecReorderedPkts Counter32
  fecIncorrectSeqNumbers Counter32
  fecDiscontinuities Counter32

ModuleStatusEntry  
SEQUENCE    
  moduleId INTEGER
  modulePidConflictStatus INTEGER
  moduleTemperatureHigh INTEGER
  moduleTemperatureLow INTEGER
  modulePidCapaStatus INTEGER
  modulePsisiCaptureCapaStatus INTEGER
  moduleSidAllocStatus INTEGER
  moduleCaDetectStatus INTEGER
  moduleDetectStatus INTEGER
  moduleVoltageHigh INTEGER
  moduleVoltageLow INTEGER
  moduleCurrentHigh INTEGER
  moduleCurrentLow INTEGER
  moduleDaemonInitStatus INTEGER
  moduleDriverStatus INTEGER
  moduleHwStatus INTEGER
  moduleFanStatus INTEGER
  modulePowerSourceStatus INTEGER
  modulePsuOverloadStatus INTEGER
  moduleBootupProgressStatus INTEGER
  moduleBootupRetryStatus INTEGER
  moduleBootupStatus INTEGER
  moduleShutdownProgressStatus INTEGER
  moduleConnStatus INTEGER
  moduleCompatStatus INTEGER
  moduleUpcPowerLow INTEGER
  moduleUpcPowerHigh INTEGER
  moduleCalibrDataStatus INTEGER
  moduleCalibrDataCheckStatus INTEGER
  moduleDescrStatus INTEGER
  moduleBackupStatus INTEGER
  moduleNitOutputsStatus INTEGER
  moduleNitSelectionStatus INTEGER
  moduleNitConfChangeStatus INTEGER
  moduleNitDataQueryStatus INTEGER
  moduleNitWizardStatus INTEGER
  moduleQamFreqStatus INTEGER
  moduleOutputSidStatus INTEGER
  moduleConfStatus INTEGER
  moduleFreqStatus INTEGER
  moduleOutputPowerStatus INTEGER
  moduleSymrateStatus INTEGER
  moduleChanDistStatus INTEGER
  moduleLnbVoltStatus INTEGER
  moduleFecRateStatus INTEGER
  moduleLnbCurrStatus INTEGER
  moduleFreqOffsetStatus INTEGER
  moduleDescrRestartStatus INTEGER
  moduleCamRestartStatus INTEGER
  moduleEcmgStatus INTEGER
  moduleEcmStreamStatus INTEGER
  moduleEmmStatus INTEGER
  moduleEmmStreamStatus INTEGER
  moduleEcmgConnStatus INTEGER
  moduleEmmConnStatus INTEGER
  moduleEcmgSpareStatus INTEGER
  moduleBootloaderAvailStatus INTEGER
  moduleBl1UpdateProgStatus INTEGER
  moduleBl2UpdateProgStatus INTEGER
  moduleBl1UpdateStatus INTEGER
  moduleBl2UpdateStatus INTEGER
  moduleActiveBackupStatus INTEGER
  moduleConfProgressStatus INTEGER
  modulePresenceStatus INTEGER
  moduleProcessRestartStatus INTEGER
  moduleBackupLicenseStatus INTEGER
  modulePsisiEditorLicenseStatus INTEGER
  moduleMuxLicenseStatus INTEGER
  moduleDemuxLicenseStatus INTEGER
  moduleDvbLicenseStatus INTEGER
  moduleMsdLicenseStatus INTEGER
  moduleDvbs2LicenseStatus INTEGER
  moduleDvbt2LicenseStatus INTEGER
  moduleScsLicenseStatus INTEGER
  moduleCliLoginStatus INTEGER
  moduleRedunActivationStatus INTEGER
  moduleExtioPinSignalingStatus INTEGER
  moduleBackupPsuStatus INTEGER
  moduleIntrusionStatus INTEGER
  moduleRedunStatus INTEGER
  moduleBackupHwStatus INTEGER
  moduleSwUpdateProgress INTEGER
  moduleSwUpdateStatus INTEGER
  moduleEitLicenseStatus INTEGER
  moduleDescramblingStatus INTEGER
  moduleDvbTimeStatus INTEGER
  moduleTunerDcFeedStatus INTEGER
  moduleTunerPlpSelectionReqStatus INTEGER
  moduleTunerPlpStatus INTEGER
  moduleTunerHierarchyStatus INTEGER
  moduleEcmStatus INTEGER
  moduleScramConflictStatus INTEGER
  moduleScramSharedStatus INTEGER
  moduleBackupVoltageHigh INTEGER
  moduleBackupVoltageLow INTEGER
  moduleSdtTableStatus INTEGER
  moduleDescramblingRestart INTEGER
  moduleCaModuleRestart INTEGER
  moduleCaMenuStatus INTEGER
  moduleInvalidCamRouting INTEGER
  moduleNitSidConflict INTEGER
  moduleLicenseMissingFEC INTEGER
  moduleFecCorrectionStatus INTEGER
  moduleFecPacketDropStatus INTEGER
  moduleFecMediaPktsStatus INTEGER
  moduleSfpLinkStatus INTEGER
  moduleBackupSyncModeOff INTEGER
  moduleBackupSyncModeManual INTEGER
  moduleBackupSyncModeAuto INTEGER
  moduleBackupSyncConfStatus INTEGER
  moduleBackupSyncStatus INTEGER
  moduleBackupSyncSwCompatibility INTEGER
  moduleBackupSyncHwCompatibility INTEGER
  moduleBackupSyncConfFaultStatus INTEGER
  moduleBackupSyncConnectionStatus INTEGER
  moduleBackupSyncFromBackupStatus INTEGER
  moduleBackupSyncRebootStatus INTEGER
  moduleBackupSyncLicenseCompatStatus INTEGER
  moduleBackupSyncLicenseCompareStatus INTEGER
  moduleDeviceFirstBootStatus INTEGER
  modulePartitionConfigurationBackup INTEGER
  modulePartitionConfigurationRestore INTEGER
  moduleSwRevertStatus INTEGER
  moduleMaxOutputPidsStatus INTEGER
  moduleUserRebootStatus INTEGER
  moduleRemovalStatus INTEGER
  moduleInsertionStatus INTEGER
  moduleSptsInputConfStatus INTEGER

IfStatusEntry  
SEQUENCE    
  ifId INTEGER
  ifDirection INTEGER
  ifSignalStatus INTEGER
  ifAsiLinkStatus INTEGER
  ifLinkStatus INTEGER

TsStatusEntry  
SEQUENCE    
  tsPidRemappingStatus INTEGER
  tsManualTableInsertStatus INTEGER
  tsPassthruDupStatus INTEGER
  tsSyncStatus INTEGER
  tsRxStatus INTEGER
  tsInputBufferStatus INTEGER
  tsNetworkStatus INTEGER
  tsPsisiCapaStatus INTEGER
  tsMultiplexDiscardStatus INTEGER
  tsMultiplexDelayStatus INTEGER
  tsCbrOversubscriptionStatus INTEGER
  tsCbrDiscardStatus INTEGER
  tsIpInputCapaStatus INTEGER
  tsEitReinsertCapaStatus INTEGER
  tsSectionCapaStatus INTEGER
  tsRtpInputStatus INTEGER
  tsRtpSeqStatus INTEGER
  tsTdtTotGenStatus INTEGER
  tsSttGenStatus INTEGER
  tsFecPacketCorrectionStatus INTEGER
  tsFecInputAnomalyStatus INTEGER
  tsFecCorrectionCapacityStatus INTEGER
  tsIpMirrorOutputPacketLossStatus INTEGER

ServiceStatusEntry  
SEQUENCE    
  serviceId INTEGER
  serviceStatus INTEGER

PidStatusEntry  
SEQUENCE    
  pId INTEGER
  pidStatus INTEGER

Defined Values

general 1.3.6.1.4.1.3715.17.1
OBJECT IDENTIFIER    

deviceName 1.3.6.1.4.1.3715.17.1.1
The identification name ('aliasname') of the device
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

generalStatus 1.3.6.1.4.1.3715.17.1.2
General status of device
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER statusAlert(1), statusCritical(2), statusError(3), statusWarning(4), statusNotice(5), statusInformational(6), statusDebug(7)  

redundancyStatus 1.3.6.1.4.1.3715.17.1.3
Status of device in 1+1 backup operation mode
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER redundancyStandalone(1), redundancyMaster(16), redundancyMasterHandover(24), redundancyBackup(32), redundancyBackupHandover(40), redundancyError(64)  

hwSerialNumber 1.3.6.1.4.1.3715.17.1.10
Device serial number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

hwType 1.3.6.1.4.1.3715.17.1.11
The hardware type name of the device
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

hwVersion 1.3.6.1.4.1.3715.17.1.12
Device hardware version
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

swVersion 1.3.6.1.4.1.3715.17.1.13
Device running software version
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

upTime 1.3.6.1.4.1.3715.17.1.14
Device uptime
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

cumulativeUptime 1.3.6.1.4.1.3715.17.1.15
Device cummulative uptime
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

statusCode 1.3.6.1.4.1.3715.17.2
OBJECT IDENTIFIER    

interfaceTypeTable 1.3.6.1.4.1.3715.17.2.1
InterfaceTypeTable lists possible interface types in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    InterfaceTypeEntry

interfaceTypeEntry 1.3.6.1.4.1.3715.17.2.1.1
Each InterfaceTypeEntry describes type of the interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceTypeEntry  

interfaceTypeId 1.3.6.1.4.1.3715.17.2.1.1.1
Interfacetype Id has two values input(1) and output(2). Values are used in other tables as index.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER input(1), output(2)  

statusCodeDeviceTable 1.3.6.1.4.1.3715.17.2.2
This table describes monitorable objects of the device. The objects may represents real objects or classes. The monitoring system or user shall not poll this table to detect device state. Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB. In this case statusCodeDeviceTable shall be used to obtains text definition of alarm.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StatusCodeDeviceEntry

statusCodeDeviceEntry 1.3.6.1.4.1.3715.17.2.2.1
Status: current Access: not-accessible
OBJECT-TYPE    
  StatusCodeDeviceEntry  

scdObjectId 1.3.6.1.4.1.3715.17.2.2.1.1
Unique identifier of the monitorable object.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

scdObjectValue 1.3.6.1.4.1.3715.17.2.2.1.2
Value of the monitorable object. The scdObjectDescriptor tells name, scale and unit of the object.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

scdObjectDescriptor 1.3.6.1.4.1.3715.17.2.2.1.3
Description of the monitorable object. Free text if object has two states or Format: Name, Scale, Unit, [optional text] ------------------------------------ Example 1 (Analogue object): 'MainVoltage, 0.01, V' Usage: scdObjectId:7 (example) scdObjectValue:2399 scdObjectDescriptor:'MainVoltage, 0.01, V' means Main voltage is 23.99 V ------------------------------------ Example 2 (Discrete object): 'TemperatureHigh, 1, high(2)/nominal(1), Alarm state of the temperature' Usage: scdObjectId:12 (example) scdObjectValue:2 means Temperature is in high alarm state. ------------------------------------
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

scdObjectAlarmValue 1.3.6.1.4.1.3715.17.2.2.1.4
When the object has this value it is in the alarm state. One object id can have only one alarm state. If more alarm states exist then new associated object needs to be created. Note that alarm state value can have only discrete values. If the value is zero then there is no alarm for this object. Example: TemperatureHigh object can have values high(2) or nominal(1). Alarm monitoring for this object is triggered by setting dmObjectAlarmValue to value 2 meaning high(2). How the alarm processing is done is out of scope of this MIB.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

statusCodeModuleTable 1.3.6.1.4.1.3715.17.2.3
This table describes monitorable objects per module inside the device. The objects may represents real objects or classes. The monitoring system or user shall not poll this table to detect device state. Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB. In this case statusCodeModuleTable shall be used to obtains text definition of alarm.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StatusCodeModuleEntry

statusCodeModuleEntry 1.3.6.1.4.1.3715.17.2.3.1
Status: current Access: not-accessible
OBJECT-TYPE    
  StatusCodeModuleEntry  

scmModuleId 1.3.6.1.4.1.3715.17.2.3.1.1
Module Id within the device (usually slot number).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..7  

scmObjectId 1.3.6.1.4.1.3715.17.2.3.1.2
Unique identifier of the monitorable object within the module.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

scmObjectValue 1.3.6.1.4.1.3715.17.2.3.1.3
Value of the monitorable object. The scmObjectDescriptor tells name, scale and unit of the object.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

scmObjectDescriptor 1.3.6.1.4.1.3715.17.2.3.1.4
Description of the monitorable object. See scdObjectDescriptor for format, example and usage.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

scmObjectAlarmValue 1.3.6.1.4.1.3715.17.2.3.1.5
See scdObjectAlarmValue for format, example and usage.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

statusCodeInterfaceTable 1.3.6.1.4.1.3715.17.2.4
This table describes monitorable objects per interface per module. The objects may represents real objects or classes. The monitoring system or user shall not poll this table to detect device state. Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB. In this case statusCodeInterfaceTable shall be used to obtains text definition of alarm.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StatusCodeInterfaceEntry

statusCodeInterfaceEntry 1.3.6.1.4.1.3715.17.2.4.1
Status: current Access: not-accessible
OBJECT-TYPE    
  StatusCodeInterfaceEntry  

sciInterfaceId 1.3.6.1.4.1.3715.17.2.4.1.1
Unique interface Id within the module (e.g. RF connector number).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

sciObjectId 1.3.6.1.4.1.3715.17.2.4.1.2
Unique identifier of the monitorable object within the interface.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

sciObjectValue 1.3.6.1.4.1.3715.17.2.4.1.3
Value of the monitorable object. The sciObjectDescriptor tells name, scale and unit of the object.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

sciObjectDescriptor 1.3.6.1.4.1.3715.17.2.4.1.4
Description of the monitorable object. See scdObjectDescriptor for format, example and usage.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sciObjectAlarmValue 1.3.6.1.4.1.3715.17.2.4.1.5
See dmObjectAlarmValue for format, example and usage.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

statusCodeTransportStreamTable 1.3.6.1.4.1.3715.17.2.5
This table describes monitorable objects of each transport stream. The objects may represents real objects or classes. The monitoring system or user shall not poll this table to detect device state. Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB. In this case statusCodeTransportStreamTable shall be used to obtains text definition of alarm.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StatusCodeTransportStreamEntry

statusCodeTransportStreamEntry 1.3.6.1.4.1.3715.17.2.5.1
Status: current Access: not-accessible
OBJECT-TYPE    
  StatusCodeTransportStreamEntry  

sctsTransportStreamId 1.3.6.1.4.1.3715.17.2.5.1.1
Unique transport stream id inside the interface.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..8192  

sctsObjectId 1.3.6.1.4.1.3715.17.2.5.1.2
Unique identifier of the monitorable object.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

sctsObjectValue 1.3.6.1.4.1.3715.17.2.5.1.3
Value of the monitorable object. The sctsObjectDescriptor tells name, scale and unit of the object.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

sctsObjectDescriptor 1.3.6.1.4.1.3715.17.2.5.1.4
Description of the monitorable object. See dmObjectDescriptor for format, example and usage.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sctsObjectAlarmValue 1.3.6.1.4.1.3715.17.2.5.1.5
See scdObjectAlarmValue for format, example and usage.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

statusCodeServiceTable 1.3.6.1.4.1.3715.17.2.6
This table describes monitorable objects of each service. The objects may represents real objects or classes. The monitoring system or user shall not poll this table to detect device state. Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB. In this case statusCodeServiceTable shall be used to obtains text definition of alarm.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StatusCodeServiceEntry

statusCodeServiceEntry 1.3.6.1.4.1.3715.17.2.6.1
Status: current Access: not-accessible
OBJECT-TYPE    
  StatusCodeServiceEntry  

scsSID 1.3.6.1.4.1.3715.17.2.6.1.1
Unique service id number inside the transport stream.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

scsObjectId 1.3.6.1.4.1.3715.17.2.6.1.2
Unique identifier of the monitorable object.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

scsObjectValue 1.3.6.1.4.1.3715.17.2.6.1.3
Value of the monitorable object. The scsObjectDescriptor tells name, scale and unit of the object.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

scsObjectDescriptor 1.3.6.1.4.1.3715.17.2.6.1.4
Description of the monitorable object. See scdObjectDescriptor for format, example and usage.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

scsServiceName 1.3.6.1.4.1.3715.17.2.6.1.5
The name of the service.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

scsObjectAlarmValue 1.3.6.1.4.1.3715.17.2.6.1.6
See scdObjectAlarmValue for format, example and usage.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

statusCodePidTable 1.3.6.1.4.1.3715.17.2.7
This table lists monitorable objects of each PID. The objects may represents real objects or classes. The monitoring system or user shall not poll this table to detect device state. Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB. In this case statusCodePidTable shall be used to obtains text definition of alarm.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StatusCodePidEntry

statusCodePidEntry 1.3.6.1.4.1.3715.17.2.7.1
Status: current Access: not-accessible
OBJECT-TYPE    
  StatusCodePidEntry  

scpPID 1.3.6.1.4.1.3715.17.2.7.1.1
Unique PID value inside the transport stream.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..8191  

scpObjectId 1.3.6.1.4.1.3715.17.2.7.1.2
Unique identifier of the monitorable object.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

scpObjectValue 1.3.6.1.4.1.3715.17.2.7.1.3
Value of the monitorable object. The scpObjectDescriptor tells name, scale and unit of the object.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

scpObjectDescriptor 1.3.6.1.4.1.3715.17.2.7.1.4
Description of the monitorable object. See scdObjectDescriptor for format, example and usage.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

scpObjectAlarmValue 1.3.6.1.4.1.3715.17.2.7.1.5
See scdObjectAlarmValue for format, example and usage.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

interface 1.3.6.1.4.1.3715.17.3
OBJECT IDENTIFIER    

ifExtTable 1.3.6.1.4.1.3715.17.3.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IfExtEntry

ifExtEntry 1.3.6.1.4.1.3715.17.3.1.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  IfExtEntry  

ifExtIndex 1.3.6.1.4.1.3715.17.3.1.1.1
A unique index for an interface. The index is of following format: SDPPVVVV, where: - S = Slot number - D = input(1) / output(2) - PP = Physical interface number - VVVV = Virtual interface number
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER  

ifExtName 1.3.6.1.4.1.3715.17.3.1.1.2
Description for the interface.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ifExtModule 1.3.6.1.4.1.3715.17.3.1.1.3
Number of the physical module or slot housing the interface.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

ifExtPhysInterface 1.3.6.1.4.1.3715.17.3.1.1.4
Physical interface number.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

ifExtLogiInterface 1.3.6.1.4.1.3715.17.3.1.1.5
Logical interface number.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

ifExtDirection 1.3.6.1.4.1.3715.17.3.1.1.6
Direction for the data going through the interface.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER input(1), output(2), both(3)  

signalPhysTable 1.3.6.1.4.1.3715.17.3.2
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SignalPhysEntry

signalPhysEntry 1.3.6.1.4.1.3715.17.3.2.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SignalPhysEntry  

signalSnr 1.3.6.1.4.1.3715.17.3.2.1.2
Recent signal to noise ratio in 1/10th of dB.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

signalSnrMin 1.3.6.1.4.1.3715.17.3.2.1.3
Lowest measured SNR value since last device startup or last counter reset.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

signalSnrMax 1.3.6.1.4.1.3715.17.3.2.1.4
Highest measured SNR value since last device startup or last counter reset.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

signalCcErrors 1.3.6.1.4.1.3715.17.3.2.1.5
The number of continuity errors since last device startup or last counter reset.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

signalBer 1.3.6.1.4.1.3715.17.3.2.1.6
Calculated bit error ratio of the signal.
Status: current Access: read-only
OBJECT-TYPE    
  Float  

signalVber 1.3.6.1.4.1.3715.17.3.2.1.7
Calculated Viterbi bit error ratio of the signal.
Status: current Access: read-only
OBJECT-TYPE    
  Float  

transferTable 1.3.6.1.4.1.3715.17.3.3
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TransferEntry

transferEntry 1.3.6.1.4.1.3715.17.3.3.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  TransferEntry  

transBitrate 1.3.6.1.4.1.3715.17.3.3.1.2
Recent measured bitrate of the interface in kilobits per second.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

transBitrateMin 1.3.6.1.4.1.3715.17.3.3.1.3
Lowest measured bitrate since last device startup or last counter reset. Writing clears the counter.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

transBitrateMax 1.3.6.1.4.1.3715.17.3.3.1.4
Highest measured bitrate since last device startup or last counter reset. Writing clears the counter.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

proMpegFecTable 1.3.6.1.4.1.3715.17.3.20
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ProMpegFecEntry

proMpegFecEntry 1.3.6.1.4.1.3715.17.3.20.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  ProMpegFecEntry  

fecValidPkts 1.3.6.1.4.1.3715.17.3.20.1.1
Number of media stream packets received. Writing any value in this oid will clear all ProMpegFec related counters on the current interface.
Status: current Access: read-write
OBJECT-TYPE    
  Counter32  

fecUncorrectedPkts 1.3.6.1.4.1.3715.17.3.20.1.2
Number of missing media stream packets after FEC decoding. Writing any value in this oid will clear all ProMpegFec related counters on the current interface.
Status: current Access: read-write
OBJECT-TYPE    
  Counter32  

fecCorrectedPkts 1.3.6.1.4.1.3715.17.3.20.1.3
Number of corrected packets after FEC decoding. Writing any value in this oid will clear all ProMpegFec related counters on the current interface.
Status: current Access: read-write
OBJECT-TYPE    
  Counter32  

fecDuplicatePkts 1.3.6.1.4.1.3715.17.3.20.1.4
Number of duplicate packets received. Defined as a received packet with the same RTP sequence number as any of the packets already in the decoding buffer. All duplicate packets are automatically discarded and do not cause missing packets or duplicates to the output stream. Writing any value in this oid will clear all ProMpegFec related counters on the current interface.
Status: current Access: read-write
OBJECT-TYPE    
  Counter32  

fecReorderedPkts 1.3.6.1.4.1.3715.17.3.20.1.5
Number of reordered packets received. Defined as a received packet which RTP sequence number is smaller than the highest RTP sequence number already received, excluding duplicate packets and packets which are out of the decoding buffer range. These packets will be re-ordered and do not cause missing packets to the output stream. Writing any value in this oid will clear all ProMpegFec related counters on the current interface.
Status: current Access: read-write
OBJECT-TYPE    
  Counter32  

fecIncorrectSeqNumbers 1.3.6.1.4.1.3715.17.3.20.1.6
Number of received media packets that have RTP sequence number out of decoding buffer range. All these packet are discarded. If 10 consecutive packets are out of range then decoding buffer is flushed and re-initialised i.e. all packets in the buffer are discarded. Incorrect sequence numbers counter will not be incremented if decoding buffer has been flushed. Writing any value in this oid will clear all ProMpegFec related counters on the current interface.
Status: current Access: read-write
OBJECT-TYPE    
  Counter32  

fecDiscontinuities 1.3.6.1.4.1.3715.17.3.20.1.7
Number of RTP sequence number discontinuities after FEC decoding. Discontinuity is detected when the sequence number of received RTP packet (after decoding) is not equal to sequence number of previous packet. Discontinuities are typically detected when there are uncorrected packets in the stream, or when there are brief interruptions in the stream (in range of about 1-20 seconds). Also abrupt change of stream source will be counted as discontinuity because of jump in RTP sequence numbers. Writing any value in this oid will clear all ProMpegFec related counters on the current interface.
Status: current Access: read-write
OBJECT-TYPE    
  Counter32  

notifications 1.3.6.1.4.1.3715.17.4
OBJECT IDENTIFIER    

statusFlags 1.3.6.1.4.1.3715.17.5
OBJECT IDENTIFIER    

moduleStatusTable 1.3.6.1.4.1.3715.17.5.2
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ModuleStatusEntry

moduleStatusEntry 1.3.6.1.4.1.3715.17.5.2.1
Status: current Access: not-accessible
OBJECT-TYPE    
  ModuleStatusEntry  

moduleId 1.3.6.1.4.1.3715.17.5.2.1.1
Module identifier
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER  

modulePidConflictStatus 1.3.6.1.4.1.3715.17.5.2.1.4
PID conflict status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER pidOk(1), pidConflict(2)  

moduleTemperatureHigh 1.3.6.1.4.1.3715.17.5.2.1.6
High temperature status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER temperatureNominal(1), temperatureHigh(2)  

moduleTemperatureLow 1.3.6.1.4.1.3715.17.5.2.1.7
Low temperature status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER temperatureNominal(1), temperatureLow(2)  

modulePidCapaStatus 1.3.6.1.4.1.3715.17.5.2.1.4104
Module PID capacity status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER capacityNominal(1), capacityExceeded(2)  

modulePsisiCaptureCapaStatus 1.3.6.1.4.1.3715.17.5.2.1.4105
Module PSI/SI table capture capacity status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER capacityNominal(1), capacityExceeded(2)  

moduleSidAllocStatus 1.3.6.1.4.1.3715.17.5.2.1.4106
Module service ID allocation capacity status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER sidAllocOk(1), sidAllocCapaExceeded(2)  

moduleCaDetectStatus 1.3.6.1.4.1.3715.17.5.2.1.4108
CA module detection status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER moduleOk(1), moduleMissing(2)  

moduleDetectStatus 1.3.6.1.4.1.3715.17.5.2.1.4111
Module detection status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER moduleOk(1), moduleUnknown(2)  

moduleVoltageHigh 1.3.6.1.4.1.3715.17.5.2.1.4112
High voltage status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER voltageNominal(1), voltageHigh(2)  

moduleVoltageLow 1.3.6.1.4.1.3715.17.5.2.1.4113
Low voltage status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER voltageNominal(1), voltageLow(2)  

moduleCurrentHigh 1.3.6.1.4.1.3715.17.5.2.1.4114
High current status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER currentNominal(1), currentHigh(2)  

moduleCurrentLow 1.3.6.1.4.1.3715.17.5.2.1.4115
Low current status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER currentNominal(1), currentLow(2)  

moduleDaemonInitStatus 1.3.6.1.4.1.3715.17.5.2.1.4127
Module daemon initialization status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER daemonNominal(1), daemonInitFailed(2)  

moduleDriverStatus 1.3.6.1.4.1.3715.17.5.2.1.4129
Module device driver status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER driverNominal(1), driverFailure(2)  

moduleHwStatus 1.3.6.1.4.1.3715.17.5.2.1.4130
Module hardware status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER hwNominal(1), hwFailure(2)  

moduleFanStatus 1.3.6.1.4.1.3715.17.5.2.1.4131
Fan status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER fanNominal(1), fanFailure(2)  

modulePowerSourceStatus 1.3.6.1.4.1.3715.17.5.2.1.4132
Power source status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER runningOnMainPower(1), runningOnBackupPower(2)  

modulePsuOverloadStatus 1.3.6.1.4.1.3715.17.5.2.1.4133
Power supply overload status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER psuNominal(1), psuOverloaded(2)  

moduleBootupProgressStatus 1.3.6.1.4.1.3715.17.5.2.1.4134
Module bootup progress
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER moduleNominal(1), moduleBootingUp(2)  

moduleBootupRetryStatus 1.3.6.1.4.1.3715.17.5.2.1.4135
Module bootup retry status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER moduleNominal(1), moduleBootingRetrying(2)  

moduleBootupStatus 1.3.6.1.4.1.3715.17.5.2.1.4136
Module bootup status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER moduleNominal(1), moduleBootFailure(2)  

moduleShutdownProgressStatus 1.3.6.1.4.1.3715.17.5.2.1.4137
Module shutdown progress
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER moduleNominal(1), moduleShuttingDown(2)  

moduleConnStatus 1.3.6.1.4.1.3715.17.5.2.1.4138
Module connection status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER connectionNominal(1), connectionLost(2)  

moduleCompatStatus 1.3.6.1.4.1.3715.17.5.2.1.4139
Module compatibility status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER moduleNominal(1), moduleIncompatible(2)  

moduleUpcPowerLow 1.3.6.1.4.1.3715.17.5.2.1.4147
Module UPC input power low status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ucpPowerNominal(1), ucpPowerLow(2)  

moduleUpcPowerHigh 1.3.6.1.4.1.3715.17.5.2.1.4148
Module UPC input power high status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ucpPowerNominal(1), ucpPowerHigh(2)  

moduleCalibrDataStatus 1.3.6.1.4.1.3715.17.5.2.1.4149
Module calibration data status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER calibrationDataNominal(1), calibrationDataMissing(2)  

moduleCalibrDataCheckStatus 1.3.6.1.4.1.3715.17.5.2.1.4150
Module calibration data check status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER checkOk(1), checkSkipped(2)  

moduleDescrStatus 1.3.6.1.4.1.3715.17.5.2.1.4151
Module descrambling status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER descramblingOk(1), descramblingFailure(2)  

moduleBackupStatus 1.3.6.1.4.1.3715.17.5.2.1.4153
Module backup status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER moduleNominal(1), moduleSwitchedToBackup(2)  

moduleNitOutputsStatus 1.3.6.1.4.1.3715.17.5.2.1.4154
Supported Nit output module status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nitOutputsNominal(1), noSupportedNitOutputs(2)  

moduleNitSelectionStatus 1.3.6.1.4.1.3715.17.5.2.1.4155
Nit output selection status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nitSelectionNominal(1), noSelectedNitOutputs(2)  

moduleNitConfChangeStatus 1.3.6.1.4.1.3715.17.5.2.1.4156
Nit configuration change status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nitConfNominal(1), nitConfChanged(2)  

moduleNitDataQueryStatus 1.3.6.1.4.1.3715.17.5.2.1.4157
Nit data query status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nitDataQueryNominal(1), nitDataQueryFailure(2)  

moduleNitWizardStatus 1.3.6.1.4.1.3715.17.5.2.1.4158
Nit wizard status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nitWizardNominal(1), nitWizardFailure(2)  

moduleQamFreqStatus 1.3.6.1.4.1.3715.17.5.2.1.4159
QAM output unique frequency status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER qamFreqUnique(1), qamFreqDuplicate(2)  

moduleOutputSidStatus 1.3.6.1.4.1.3715.17.5.2.1.4173
Module output SID status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER sidOk(1), sidConflict(2)  

moduleConfStatus 1.3.6.1.4.1.3715.17.5.2.1.4175
Module configuration status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER configurationOk(1), configurationUnsupported(2)  

moduleFreqStatus 1.3.6.1.4.1.3715.17.5.2.1.4176
Module frequency configuration range status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER freqOk(1), freqOutOfRange(2)  

moduleOutputPowerStatus 1.3.6.1.4.1.3715.17.5.2.1.4177
Module output power status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER powerOk(1), powerOutOfRange(2)  

moduleSymrateStatus 1.3.6.1.4.1.3715.17.5.2.1.4178
Module symbol rate configuration status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER symbolRateOk(1), symbolRateOutOfRange(2)  

moduleChanDistStatus 1.3.6.1.4.1.3715.17.5.2.1.4179
Module channel distance configuration status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER chanDistOk(1), chanDistTooNarrow(2)  

moduleLnbVoltStatus 1.3.6.1.4.1.3715.17.5.2.1.4180
Module LNB voltage configuration status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER lnbVoltageOk(1), lnbVoltageInvalid(2)  

moduleFecRateStatus 1.3.6.1.4.1.3715.17.5.2.1.4181
Module FEC rate configuration vs modulation status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER fecRateOk(1), fecRateInvalid(2)  

moduleLnbCurrStatus 1.3.6.1.4.1.3715.17.5.2.1.4182
Module LNB current status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER lnbCurrentOk(1), lnbCurrentInvalid(2)  

moduleFreqOffsetStatus 1.3.6.1.4.1.3715.17.5.2.1.4183
Module frequency offset configuration status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER freqOffsetOk(1), freqOffsetInvalid(2)  

moduleDescrRestartStatus 1.3.6.1.4.1.3715.17.5.2.1.4185
Module descrambling restart status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER descramblingNominal(1), descramblingRestarting(2)  

moduleCamRestartStatus 1.3.6.1.4.1.3715.17.5.2.1.4186
Module CAM restart status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER camNominal(1), camRestarting(2)  

moduleEcmgStatus 1.3.6.1.4.1.3715.17.5.2.1.4187
Ecmg status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ecmgNominal(1), ecmgFailure(2)  

moduleEcmStreamStatus 1.3.6.1.4.1.3715.17.5.2.1.4188
Ecm stream status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ecmStreamNominal(1), ecmStreamFailure(2)  

moduleEmmStatus 1.3.6.1.4.1.3715.17.5.2.1.4189
Emm status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER emmNominal(1), emmFailure(2)  

moduleEmmStreamStatus 1.3.6.1.4.1.3715.17.5.2.1.4190
Emm stream status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER emmStreamNominal(1), emmStreamFailure(2)  

moduleEcmgConnStatus 1.3.6.1.4.1.3715.17.5.2.1.4191
Ecmg connection status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ecmgConnNominal(1), ecmgNotConnected(2)  

moduleEmmConnStatus 1.3.6.1.4.1.3715.17.5.2.1.4192
Emm connection status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER emmConnNominal(1), emmNotConnected(2)  

moduleEcmgSpareStatus 1.3.6.1.4.1.3715.17.5.2.1.4194
Ecmg spare connection status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ecmgNominal(1), ecmgSwitchedToSpare(2)  

moduleBootloaderAvailStatus 1.3.6.1.4.1.3715.17.5.2.1.4195
Module bootloader availability status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER bootloaderOk(1), bootloaderObsolete(2)  

moduleBl1UpdateProgStatus 1.3.6.1.4.1.3715.17.5.2.1.4196
Module bootloader update progress
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER bootloaderNominal(1), bootloaderUpdating(2)  

moduleBl2UpdateProgStatus 1.3.6.1.4.1.3715.17.5.2.1.4197
Module bootloader update progress
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER bootloaderNominal(1), bootloaderUpdating(2)  

moduleBl1UpdateStatus 1.3.6.1.4.1.3715.17.5.2.1.4198
Module bootloader update status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER bootloaderNominal(1), bootloaderUpdateFailure(2)  

moduleBl2UpdateStatus 1.3.6.1.4.1.3715.17.5.2.1.4199
Module bootloader update status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER bootloaderNominal(1), bootloaderUpdateFailure(2)  

moduleActiveBackupStatus 1.3.6.1.4.1.3715.17.5.2.1.4203
Backup module status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER backupPassive(1), backupActive(2)  

moduleConfProgressStatus 1.3.6.1.4.1.3715.17.5.2.1.4205
Module configuration progress
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER moduleNominal(1), moduleConfiguring(2)  

modulePresenceStatus 1.3.6.1.4.1.3715.17.5.2.1.4206
Module presence progress
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER moduleNominal(1), noModule(2)  

moduleProcessRestartStatus 1.3.6.1.4.1.3715.17.5.2.1.4208
Process restart status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER processesNominal(1), processRestarted(2)  

moduleBackupLicenseStatus 1.3.6.1.4.1.3715.17.5.2.1.4209
Backup license status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER licenseOk(1), notLicensed(2)  

modulePsisiEditorLicenseStatus 1.3.6.1.4.1.3715.17.5.2.1.4210
PSI/SI editor license status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER licenseOk(1), notLicensed(2)  

moduleMuxLicenseStatus 1.3.6.1.4.1.3715.17.5.2.1.4211
Multiplexing license status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER licenseOk(1), notLicensed(2)  

moduleDemuxLicenseStatus 1.3.6.1.4.1.3715.17.5.2.1.4212
Demultiplexing license status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER licenseOk(1), notLicensed(2)  

moduleDvbLicenseStatus 1.3.6.1.4.1.3715.17.5.2.1.4213
DVB processing license status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER licenseOk(1), notLicensed(2)  

moduleMsdLicenseStatus 1.3.6.1.4.1.3715.17.5.2.1.4214
MSD license status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER licenseOk(1), notLicensed(2)  

moduleDvbs2LicenseStatus 1.3.6.1.4.1.3715.17.5.2.1.4215
DVB-S2 processing license status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER licenseOk(1), notLicensed(2)  

moduleDvbt2LicenseStatus 1.3.6.1.4.1.3715.17.5.2.1.4216
DVB-T2 processing license status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER licenseOk(1), notLicensed(2)  

moduleScsLicenseStatus 1.3.6.1.4.1.3715.17.5.2.1.4217
Scs license status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER licenseValid(1), notLicensed(2)  

moduleCliLoginStatus 1.3.6.1.4.1.3715.17.5.2.1.4218
CLI login status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER cliNotLoggedIn(1), cliLoggedIn(2)  

moduleRedunActivationStatus 1.3.6.1.4.1.3715.17.5.2.1.4222
Redundancy activation status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER redundancyPassive(1), redundancyActivated(2)  

moduleExtioPinSignalingStatus 1.3.6.1.4.1.3715.17.5.2.1.4223
EXT-IO pin status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER extioPinNominal(1), extioPinSignaled(2)  

moduleBackupPsuStatus 1.3.6.1.4.1.3715.17.5.2.1.4224
Backup power supply status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER backupPsuNominal(1), backupPsuFailure(2)  

moduleIntrusionStatus 1.3.6.1.4.1.3715.17.5.2.1.4225
Intrusion detection status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER intrusionNominal(1), intrusionDetected(2)  

moduleRedunStatus 1.3.6.1.4.1.3715.17.5.2.1.4227
Redundancy status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER redundancyOk(1), redundancyFailure(2)  

moduleBackupHwStatus 1.3.6.1.4.1.3715.17.5.2.1.4230
Hardware backup support status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER backupHwOk(1), backupHwNotSupported(2)  

moduleSwUpdateProgress 1.3.6.1.4.1.3715.17.5.2.1.4231
Software update progress
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER swUpdateInactive(1), swUpdateInProgress(2)  

moduleSwUpdateStatus 1.3.6.1.4.1.3715.17.5.2.1.4233
Software update status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER swNominal(1), swUpdateFailure(2)  

moduleEitLicenseStatus 1.3.6.1.4.1.3715.17.5.2.1.4235
EIT license status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER licenseValid(1), notLicensed(2)  

moduleDescramblingStatus 1.3.6.1.4.1.3715.17.5.2.1.4237
Descrambling status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER descramblingNominal(1), descramblingFailure(2)  

moduleDvbTimeStatus 1.3.6.1.4.1.3715.17.5.2.1.4243
DVB time detection status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER dvbTimeNominal(1), dvbTimeMissing(2)  

moduleTunerDcFeedStatus 1.3.6.1.4.1.3715.17.5.2.1.4245
Tuner DC feed current status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER currentNominal(1), currentOutOfRange(2)  

moduleTunerPlpSelectionReqStatus 1.3.6.1.4.1.3715.17.5.2.1.4247
Tuner data PLP ID requirement status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER plpSelectionOk(1), plpSelectionRequired(2)  

moduleTunerPlpStatus 1.3.6.1.4.1.3715.17.5.2.1.4248
Tuner data PLP ID validity status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER plpSelectionValid(1), plpSelectionNotValid(2)  

moduleTunerHierarchyStatus 1.3.6.1.4.1.3715.17.5.2.1.4249
Status of transmission hierarchy
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER hierarchyOk(1), hierarchyInvalid(2)  

moduleEcmStatus 1.3.6.1.4.1.3715.17.5.2.1.4250
ECM stream connection status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ecmNominal(1), ecmMissing(2)  

moduleScramConflictStatus 1.3.6.1.4.1.3715.17.5.2.1.4251
Module scrambling shared component conflict status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER scramblingNominal(1), scramblingConflict(2)  

moduleScramSharedStatus 1.3.6.1.4.1.3715.17.5.2.1.4252
Module scrambling shared component status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER scramblingNominal(1), scramblingSharedComponent(2)  

moduleBackupVoltageHigh 1.3.6.1.4.1.3715.17.5.2.1.4253
Backup high voltage status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER voltageNominal(1), voltageHigh(2)  

moduleBackupVoltageLow 1.3.6.1.4.1.3715.17.5.2.1.4254
Backup low voltage status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER voltageNominal(1), voltageLow(2)  

moduleSdtTableStatus 1.3.6.1.4.1.3715.17.5.2.1.4255
Sdt table template status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER sdtTableOk(1), invalidSdtTableTemplate(2)  

moduleDescramblingRestart 1.3.6.1.4.1.3715.17.5.2.1.4256
Descrambling restart status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER descramblingNominal(1), descramblingRestarting(2)  

moduleCaModuleRestart 1.3.6.1.4.1.3715.17.5.2.1.4257
CA module restart status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER caModuleNominal(1), caModuleRestarting(2)  

moduleCaMenuStatus 1.3.6.1.4.1.3715.17.5.2.1.4258
CA menu access status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER caMenuNominal(1), caMenuOpen(2)  

moduleInvalidCamRouting 1.3.6.1.4.1.3715.17.5.2.1.4259
CAM routing status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER camRoutingNominal(1), camRoutingInvalid(2)  

moduleNitSidConflict 1.3.6.1.4.1.3715.17.5.2.1.4260
Nit / Sid conflict status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nitSidNominal(1), nitSidConflict(2)  

moduleLicenseMissingFEC 1.3.6.1.4.1.3715.17.5.2.1.4262
FEC license status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER licenseOk(1), licenseMissing(2)  

moduleFecCorrectionStatus 1.3.6.1.4.1.3715.17.5.2.1.4263
Fec packet correction status. Correction overload (2) is result of too many simultaneous missing packets.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER correctionNominal(1), correctionOverload(2)  

moduleFecPacketDropStatus 1.3.6.1.4.1.3715.17.5.2.1.4264
FEC packet discarding status. Packet discarding (2) is resulted by too high bitrate.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER packetsNominal(1), packetsDropped(2)  

moduleFecMediaPktsStatus 1.3.6.1.4.1.3715.17.5.2.1.4265
Fec media packet discarding status. Packet discarding (2) is resulted by too high bitrate.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER packetsNominal(1), packetsDiscarded(2)  

moduleSfpLinkStatus 1.3.6.1.4.1.3715.17.5.2.1.4269
SFP link status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER sfpLinkNominal(1), sfpLinkDown(2)  

moduleBackupSyncModeOff 1.3.6.1.4.1.3715.17.5.2.1.4272
Backup sync mode off status flag
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER modeNominal(1), modeOff(2)  

moduleBackupSyncModeManual 1.3.6.1.4.1.3715.17.5.2.1.4273
Backup sync mode manual status flag
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER modeNominal(1), modeManual(2)  

moduleBackupSyncModeAuto 1.3.6.1.4.1.3715.17.5.2.1.4274
Backup sync mode automatic status flag
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER modeNominal(1), modeAuto(2)  

moduleBackupSyncConfStatus 1.3.6.1.4.1.3715.17.5.2.1.4275
Backup sync configuration change status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER configurationNominal(1), configurationChanged(2)  

moduleBackupSyncStatus 1.3.6.1.4.1.3715.17.5.2.1.4276
Backup configuration synchronization status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER syncNominal(1), synchronizing(2)  

moduleBackupSyncSwCompatibility 1.3.6.1.4.1.3715.17.5.2.1.4278
Software version compatibility for backup sync
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER swCompatible(1), swIncompatible(2)  

moduleBackupSyncHwCompatibility 1.3.6.1.4.1.3715.17.5.2.1.4279
Hardware version compatibility for backup sync
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER hwCompatible(1), hwIncompatible(2)  

moduleBackupSyncConfFaultStatus 1.3.6.1.4.1.3715.17.5.2.1.4280
Backup sync configuration fault status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER configurationNominal(1), configurationFault(2)  

moduleBackupSyncConnectionStatus 1.3.6.1.4.1.3715.17.5.2.1.4281
Backup sync connection status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER connectionNominal(1), connectionLost(2)  

moduleBackupSyncFromBackupStatus 1.3.6.1.4.1.3715.17.5.2.1.4283
Status flag for backup autosync from backup to main
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER syncNominal(1), syncNotPossible(2)  

moduleBackupSyncRebootStatus 1.3.6.1.4.1.3715.17.5.2.1.4284
Status flag for rebooting pair device to new configuration
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER pairDevNominal(1), pairDevRebooting(2)  

moduleBackupSyncLicenseCompatStatus 1.3.6.1.4.1.3715.17.5.2.1.4285
License compatibility status flag for backup sync
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER licensesCompatible(1), licensesIncompatible(2)  

moduleBackupSyncLicenseCompareStatus 1.3.6.1.4.1.3715.17.5.2.1.4286
Backup sync license comparing status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER licenseNominal(1), licenseComparing(2)  

moduleDeviceFirstBootStatus 1.3.6.1.4.1.3715.17.5.2.1.4288
Status flag for device first boot operations
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER firstBootNominal(1), firstBootInProgress(2)  

modulePartitionConfigurationBackup 1.3.6.1.4.1.3715.17.5.2.1.4289
Status flag for partition configuration backup operation
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER configurationNominal(1), configurationBackupInProgress(2)  

modulePartitionConfigurationRestore 1.3.6.1.4.1.3715.17.5.2.1.4290
Status flag for partition configuration restore operation
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER configurationNominal(1), configurationRestoreInProgress(2)  

moduleSwRevertStatus 1.3.6.1.4.1.3715.17.5.2.1.4291
Software revertion status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER swNominal(1), swRevertInProgress(2)  

moduleMaxOutputPidsStatus 1.3.6.1.4.1.3715.17.5.2.1.4292
Status flag for maximum number of Pid allocations
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER pidsNominal(1), maxPidsUsed(2)  

moduleUserRebootStatus 1.3.6.1.4.1.3715.17.5.2.1.4293
Status flag for user initiated reboot
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER moduleNominal(1), moduleRebootedByUser(2)  

moduleRemovalStatus 1.3.6.1.4.1.3715.17.5.2.1.4294
Status flag for module removal
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER moduleNominal(1), moduleRemoved(2)  

moduleInsertionStatus 1.3.6.1.4.1.3715.17.5.2.1.4295
Status flag for module insertion
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER moduleNominal(1), moduleInserted(2)  

moduleSptsInputConfStatus 1.3.6.1.4.1.3715.17.5.2.1.4296
Status flag for input spts misconfiguration
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER sptsInputNominal(1), inputNotSpts(2)  

ifStatusTable 1.3.6.1.4.1.3715.17.5.3
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IfStatusEntry

ifStatusEntry 1.3.6.1.4.1.3715.17.5.3.1
Status: current Access: not-accessible
OBJECT-TYPE    
  IfStatusEntry  

ifId 1.3.6.1.4.1.3715.17.5.3.1.1
Interface identifier
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER  

ifDirection 1.3.6.1.4.1.3715.17.5.3.1.2
Interface data direction
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER input(1), output(2), both(3)  

ifSignalStatus 1.3.6.1.4.1.3715.17.5.3.1.4097
Interface signal status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER signalOk(1), signalMissing(2)  

ifAsiLinkStatus 1.3.6.1.4.1.3715.17.5.3.1.4102
ASI link status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER linkOk(1), linkDown(2)  

ifLinkStatus 1.3.6.1.4.1.3715.17.5.3.1.4226
Interface link status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER linkOk(1), linkDown(2)  

tsStatusTable 1.3.6.1.4.1.3715.17.5.4
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TsStatusEntry

tsStatusEntry 1.3.6.1.4.1.3715.17.5.4.1
Status: current Access: not-accessible
OBJECT-TYPE    
  TsStatusEntry  

tsPidRemappingStatus 1.3.6.1.4.1.3715.17.5.4.1.5
TS PID remapping status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER pidNominal(1), pidRemapped(2)  

tsManualTableInsertStatus 1.3.6.1.4.1.3715.17.5.4.1.8
TS manual table insertion status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER insertOk(1), insertFailure(2)  

tsPassthruDupStatus 1.3.6.1.4.1.3715.17.5.4.1.11
TS output service passthrough duplication status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER servicesNominal(1), servicesBlocked(2)  

tsSyncStatus 1.3.6.1.4.1.3715.17.5.4.1.4098
TS sync status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER syncOk(1), noSync(2)  

tsRxStatus 1.3.6.1.4.1.3715.17.5.4.1.4099
TS Rx error status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER rxNominal(1), rxErrors(2)  

tsInputBufferStatus 1.3.6.1.4.1.3715.17.5.4.1.4100
TS input buffer status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER bufferNominal(1), bufferOverflow(2)  

tsNetworkStatus 1.3.6.1.4.1.3715.17.5.4.1.4103
TS network ID status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER netOk(1), netForbidden(2)  

tsPsisiCapaStatus 1.3.6.1.4.1.3715.17.5.4.1.4109
TS PSI/SI insertion capacity status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER capacityNominal(1), capacityExceeded(2)  

tsMultiplexDiscardStatus 1.3.6.1.4.1.3715.17.5.4.1.4110
TS multiplex packet discard status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER muxNominal(1), muxPacketsDiscarded(2)  

tsMultiplexDelayStatus 1.3.6.1.4.1.3715.17.5.4.1.4228
TS multiplex packet delay status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER muxNominal(1), muxPacketsDelayed(2)  

tsCbrOversubscriptionStatus 1.3.6.1.4.1.3715.17.5.4.1.4229
TS CBR oversubscription status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER cbrNominal(1), cbrOversubscription(2)  

tsCbrDiscardStatus 1.3.6.1.4.1.3715.17.5.4.1.4236
TS CBR packet discard due to oversubscription status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER cbrNominal(1), cbrPacketsDiscarded(2)  

tsIpInputCapaStatus 1.3.6.1.4.1.3715.17.5.4.1.4238
TS IP input capacity status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER capacityNominal(1), capacityExceeded(2)  

tsEitReinsertCapaStatus 1.3.6.1.4.1.3715.17.5.4.1.4239
TS EIT reinsert capacity status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER capacityNominal(1), capacityExceeded(2)  

tsSectionCapaStatus 1.3.6.1.4.1.3715.17.5.4.1.4240
TS section processing capacity status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER capacityNominal(1), capacityExceeded(2)  

tsRtpInputStatus 1.3.6.1.4.1.3715.17.5.4.1.4241
TS RTP input packet droip status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inputOk(1), inputPacketsDropped(2)  

tsRtpSeqStatus 1.3.6.1.4.1.3715.17.5.4.1.4242
TS RTP input packet sequence anomaly status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER seqOk(1), seqAnomalies(2)  

tsTdtTotGenStatus 1.3.6.1.4.1.3715.17.5.4.1.4246
TS output TDT/TOT table generation status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER tdtTotOk(1), tdtTotNotGenerated(2)  

tsSttGenStatus 1.3.6.1.4.1.3715.17.5.4.1.4261
TS output STT table generation status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER sttOk(1), sttNotGenerated(2)  

tsFecPacketCorrectionStatus 1.3.6.1.4.1.3715.17.5.4.1.4266
Status flag for FEC correcting packets
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER packetsNominal(1), fecCorrectedPackets(2)  

tsFecInputAnomalyStatus 1.3.6.1.4.1.3715.17.5.4.1.4267
Status flag for FEC input anomaly detection
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER fecInputNominal(1), fecInputAnomalies(2)  

tsFecCorrectionCapacityStatus 1.3.6.1.4.1.3715.17.5.4.1.4268
Fec input packets correction capacity status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER correctionCapacityNominal(1), correctionCapacityExceeded(2)  

tsIpMirrorOutputPacketLossStatus 1.3.6.1.4.1.3715.17.5.4.1.4297
Status flag for IP mirror output packet discarding
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ipOutputNominal(1), ipOutputPacketsDiscarded(2)  

serviceStatusTable 1.3.6.1.4.1.3715.17.5.5
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ServiceStatusEntry

serviceStatusEntry 1.3.6.1.4.1.3715.17.5.5.1
Status: current Access: not-accessible
OBJECT-TYPE    
  ServiceStatusEntry  

serviceId 1.3.6.1.4.1.3715.17.5.5.1.1
Service identifier
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER  

serviceStatus 1.3.6.1.4.1.3715.17.5.5.1.3
Service status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER servicePresent(1), serviceMissing(2)  

pidStatusTable 1.3.6.1.4.1.3715.17.5.6
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PidStatusEntry

pidStatusEntry 1.3.6.1.4.1.3715.17.5.6.1
Status: current Access: not-accessible
OBJECT-TYPE    
  PidStatusEntry  

pId 1.3.6.1.4.1.3715.17.5.6.1.1
Program Identifier
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..65535  

pidStatus 1.3.6.1.4.1.3715.17.5.6.1.2
PID status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER pidPresent(1), pidMissing(2)