STARTEK-PRIVATE-MIB

File: STARTEK-PRIVATE-MIB.mib (197638 bytes)

Imported modules

RFC1155-SMI SNMPv2-TC

Imported symbols

enterprises OBJECT-TYPE TimeTicks
Opaque Counter IpAddress
DisplayString

Defined Types

M828hubTableEntry  
SEQUENCE    
  m828HubTableIndex INTEGER
  m828HubModel INTEGER
  m828Hub485Address OCTET STRING
  m828HubRiFTolSw INTEGER
  m828HubRiFTolState INTEGER
  m828HubRiMask INTEGER
  m828HubRiPhDet INTEGER
  m828HubRiNsrtStatus INTEGER
  m828HubRiBcnRemStatus INTEGER
  m828RiNeighborType INTEGER
  m828RiNeighborAddr OCTET STRING
  m828RiTimeStamp TimeTicks
  m828HubRoFTolSw INTEGER
  m828HubRoFTolState INTEGER
  m828HubRoMask INTEGER
  m828HubRoPhDet INTEGER
  m828HubRoNsrtStatus INTEGER
  m828HubRoBcnRemStatus INTEGER
  m828RoNeighborType INTEGER
  m828RoNeighborAddr OCTET STRING
  m828RoTimeStamp TimeTicks
  m828HubDataRateSwitch INTEGER
  m828HubDataRateState INTEGER
  m828HubDataRateTimeStamp TimeTicks
  m828HubMgmtStatus INTEGER
  m828HubProxyAgentID OCTET STRING
  m828HubCodeVersion OCTET STRING
  m828HubRawCommandData OCTET STRING

M828hubLobeEntry  
SEQUENCE    
  m828HubIndex INTEGER
  m828HubLobePort INTEGER
  m828HubLobePhDet INTEGER
  m828HubLobeMask INTEGER
  m828HubLobeNsrtStatus INTEGER
  m828HubLobeMacAddr OCTET STRING
  m828HubLobeBcnRemStatus INTEGER
  m828HubLobeTimeStamp TimeTicks

FchassisTableEntry  
SEQUENCE    
  fChassisIndex INTEGER
  fChassisModel INTEGER
  fChassisPowStatus INTEGER
  fChassisLocation INTEGER

FTRMainRingTableEntry  
SEQUENCE    
  fTRMainRingTableIndex INTEGER
  fTRMainRingModel INTEGER
  fTRMainRing485Address OCTET STRING
  fTRMainRingSlotIndex INTEGER
  fTRMainRingChassisIndex INTEGER
  fTRMainRingRiFTolState INTEGER
  fTRMainRingRiMask INTEGER
  fTRMainRingRiPhDet INTEGER
  fTRMainRingRiNsrtStatus INTEGER
  fTRMainRingRiBcnRemStatus INTEGER
  fTRMainRingRiCableType INTEGER
  fTRMainRingRiNghbrType INTEGER
  fTRMainRingRiNghbrAddr OCTET STRING
  fTRMainRingRiTimeStamp TimeTicks
  fTRMainRingRoFTolState INTEGER
  fTRMainRingRoMask INTEGER
  fTRMainRingRoPhDet INTEGER
  fTRMainRingRoNsrtStatus INTEGER
  fTRMainRingRoBcnRemStatus INTEGER
  fTRMainRingRoCableType INTEGER
  fTRMainRingRoNghbrType INTEGER
  fTRMainRingRoNghbrAddr OCTET STRING
  fTRMainRingRoTimeStamp TimeTicks
  fTRMainRingDataRateState INTEGER
  fTRMainRingDataRateTimeStamp TimeTicks
  fTRMainRingBkPlnNsrtState INTEGER
  fTRMainRingBkPlnTimeStamp TimeTicks
  fTRMainRingLobePhDet INTEGER
  fTRMainRingLobeMask INTEGER
  fTRMainRingLobeNsrtStatus INTEGER
  fTRMainRingLobeMacAddr OCTET STRING
  fTRMainRingLobeBcnRemStatus INTEGER
  fTRMainRingLobeTimeStamp TimeTicks
  fTRMainRingMgmtStatus INTEGER
  fTRMainRingProxyAgentID OCTET STRING
  fTRMainRingAttachedAgentType INTEGER
  fTRMainRingAttachedAgentState INTEGER
  fTRMainRingTemperatureStatus INTEGER
  fTRMainRingAutoRecovControl INTEGER
  fTRMainRingAutoRecovRetries INTEGER
  fTRMainRingCodeVersion OCTET STRING
  fTRMainRingAutoRecovState INTEGER
  fTRMainRingRawCommandData OCTET STRING
  fTRMainRingPowerStatus INTEGER
  fTRMainRingCageType INTEGER
  fTRMainRingAutoRecovMode INTEGER

FTRLobeTableEntry  
SEQUENCE    
  fTRLobeTableIndex INTEGER
  fTRLobeModel INTEGER
  fTRLobe485Address OCTET STRING
  fTRLobeSlotIndex INTEGER
  fTRLobeChassisIndex INTEGER
  fTRLobeDataRateState INTEGER
  fTRLobeDataRateTimeStamp TimeTicks
  fTRLobeBkPlnNsrtState INTEGER
  fTRLobeBkPlnTimeStamp TimeTicks
  fTRLobeMgmtStatus INTEGER
  fTRLobeProxyAgentID OCTET STRING
  fTRLobeTemperatureStatus INTEGER
  fTRLobeAutoRecovControl INTEGER
  fTRLobeAutoRecovMode INTEGER
  fTRLobeAutoRecovRetries INTEGER
  fTRLobeCodeVersion OCTET STRING
  fTRLobeAutoRecovState INTEGER
  fTRLobeRawCommandData OCTET STRING
  fTRLobePowerStatus INTEGER
  fTRLobeCageType INTEGER

FTRLobeConnectEntry  
SEQUENCE    
  fTRLobeIndex INTEGER
  fTRLobeConnectPort INTEGER
  fTRLobeConnectPhDet INTEGER
  fTRLobeConnectMask INTEGER
  fTRLobeConnectNsrtStatus INTEGER
  fTRLobeConnectMacAddr OCTET STRING
  fTRLobeConnectBcnRemStatus INTEGER
  fTRLobeConnectBcnRemCause INTEGER
  fTRLobeConnectTimeStamp TimeTicks

FEthernetTableEntry  
SEQUENCE    
  fEthernetTableIndex INTEGER
  fEthernetModel INTEGER
  fEthernet485Address OCTET STRING
  fEthernetSlotIndex INTEGER
  fEthernetChassisIndex INTEGER
  fEthernetBkPlnNsrtState INTEGER
  fEthernetBkPlnTimeStamp TimeTicks
  fEthernetMgmtStatus INTEGER
  fEthernetProxyAgentID OCTET STRING
  fEthernetTemperatureStatus INTEGER
  fEthernetCodeVersion OCTET STRING
  fEthernetRawCommandData OCTET STRING
  fEthernetPowerStatus INTEGER
  fEthernetCageType INTEGER

RmonAgentOOBTableEntry  
SEQUENCE    
  rmonAgentOOBTableIndex INTEGER
  rmonAgentOOBTableDescription DisplayString
  rmonAgentOOBTableData Opaque
  rmonAgentOOBRawDataCommand OCTET STRING

RmonAgentIBTableEntry  
SEQUENCE    
  rmonAgentIBTableIndex INTEGER
  rmonAgentIBTableDescription DisplayString
  rmonAgentIBNetworkType INTEGER
  rmonAgentIBSampleInterval INTEGER
  rmonAgentIBMacFrames INTEGER
  rmonAgentIBDataFrames INTEGER
  rmonAgentIBMacBytes INTEGER
  rmonAgentIBDataBytes INTEGER
  rmonAgentIBUtilization INTEGER
  rmonAgentIBMACUtilization INTEGER
  rmonAgentIBNonMACUtilization INTEGER
  rmonAgentIBMACData0 Opaque
  rmonAgentIBMACData1 Opaque
  rmonAgentIBMACData2 Opaque
  rmonAgentIBMACData3 Opaque
  rmonAgentIBMACData4 Opaque
  rmonAgentIBMACData5 Opaque
  rmonAgentIBMACData6 Opaque
  rmonAgentIBMACData7 Opaque
  rmonAgentIBMACData8 Opaque
  rmonAgentIBMACData9 Opaque
  rmonAgentIBMACData10 Opaque
  rmonAgentIBMACData11 Opaque

RmonAgentMACStatTableEntry  
SEQUENCE    
  rmonAgentMACStatTableData Opaque

StackablehubTableEntry  
SEQUENCE    
  stackableHubTableIndex INTEGER
  stackableHubModel INTEGER
  stackableHub485Address OCTET STRING
  stackableHubRiFTolState INTEGER
  stackableHubRiMask INTEGER
  stackableHubRiPhDet INTEGER
  stackableHubRiNsrtStatus INTEGER
  stackableHubRiBcnRemStatus INTEGER
  stackableHubRiNeighborType INTEGER
  stackableHubRiNeighborAddr OCTET STRING
  stackableHubRiTimeStamp TimeTicks
  stackableHubRoFTolState INTEGER
  stackableHubRoMask INTEGER
  stackableHubRoPhDet INTEGER
  stackableHubRoNsrtStatus INTEGER
  stackableHubRoBcnRemStatus INTEGER
  stackableHubRoNeighborType INTEGER
  stackableHubRoNeighborAddr OCTET STRING
  stackableHubRoTimeStamp TimeTicks
  stackableHubDataRateState INTEGER
  stackableHubDataRateTimeStamp TimeTicks
  stackableHubMgmtStatus INTEGER
  stackableHubProxyAgentID OCTET STRING
  stackableHubAttachedAgentType INTEGER
  stackableHubAttachedAgentState INTEGER
  stackableHubTemperatureStatus INTEGER
  stackableHubAutoRecovControl INTEGER
  stackableHubAutoRecovRetries INTEGER
  stackableHubCodeVersion OCTET STRING
  stackableHubAutoRecovState INTEGER
  stackableHubRawCommandData OCTET STRING
  stackableHubAutoRecovMode INTEGER

StackablehubLobeEntry  
SEQUENCE    
  stackableHubIndex INTEGER
  stackableHubLobePort INTEGER
  stackableHubLobePhDet INTEGER
  stackableHubLobeMask INTEGER
  stackableHubLobeNsrtStatus INTEGER
  stackableHubLobeMacAddr OCTET STRING
  stackableHubLobeBcnRemStatus INTEGER
  stackableHubLobeBcnRemCause INTEGER
  stackableHubLobeTimeStamp TimeTicks

SuperStackHubTableEntry  
SEQUENCE    
  superStackHubTableIndex INTEGER
  superStackHubModel INTEGER
  superStackHub485Address OCTET STRING
  superStackHubStackPosition INTEGER
  superStackHubRiConfiguration INTEGER
  superStackHubRiFTolState INTEGER
  superStackHubRiMask INTEGER
  superStackHubRiPhDet INTEGER
  superStackHubRiNsrtStatus INTEGER
  superStackHubRiBcnRemStatus INTEGER
  superStackHubRoConfiguration INTEGER
  superStackHubRoFTolState INTEGER
  superStackHubRoMask INTEGER
  superStackHubRoPhDet INTEGER
  superStackHubRoNsrtStatus INTEGER
  superStackHubRoBcnRemStatus INTEGER
  superStackHubCascadeUpMask INTEGER
  superStackHubCascadeUpPhDet INTEGER
  superStackHubCascadeUpNsrtStatus INTEGER
  superStackHubCascadeUpBcnRemStatus INTEGER
  superStackHubCascadeDownMask INTEGER
  superStackHubCascadeDownPhDet INTEGER
  superStackHubCascadeDownNsrtStatus INTEGER
  superStackHubCascadeDownBcnRemStatus INTEGER
  superStackHubDataRateState INTEGER
  superStackHubDataDeviceTimeStamp TimeTicks
  superStackHubMgmtStatus INTEGER
  superStackHubProxyAgentID OCTET STRING
  superStackHubAttachedAgentType INTEGER
  superStackHubAttachedAgentState INTEGER
  superStackHubAttachedAgentControl INTEGER
  superStackHubTemperatureStatus INTEGER
  superStackHubPowerStatus INTEGER
  superStackHubAutoRecovControl INTEGER
  superStackHubAutoRecovRetries INTEGER
  superStackHubCodeVersion OCTET STRING
  superStackHubAutoRecovState INTEGER
  superStackHubRawCommandData OCTET STRING
  superStackHubAutoRecovMode INTEGER
  superStackHubRouterPortPhDet INTEGER
  superStackHubRouterPortMask INTEGER
  superStackHubRouterPortNsrtStatus INTEGER
  superStackHubRouterPortMacAddr OCTET STRING
  superStackHubRouterPortBcnRemStatus INTEGER
  superStackHubRouterPortBcnRemCause INTEGER

SuperStackHubLobeEntry  
SEQUENCE    
  superStackHubIndex INTEGER
  superStackHubLobePort INTEGER
  superStackHubLobeConfig INTEGER
  superStackHubLobePhDet INTEGER
  superStackHubLobeMask INTEGER
  superStackHubLobeNsrtStatus INTEGER
  superStackHubLobeMacAddr OCTET STRING
  superStackHubLobeBcnRemStatus INTEGER
  superStackHubLobeBcnRemCause INTEGER

MgrEntry  
SEQUENCE    
  mgrIndex INTEGER
  mgrIpAddr IpAddress
  mgrCommunity DisplayString
  mgrTimeStamp TimeTicks
  mgrStatus INTEGER
  mgrPhysAddr OCTET STRING Size(6..6)
  mgrInterfaceIndex INTEGER

ConfigRS232PortEntry  
SEQUENCE    
  configRS232PortIndex INTEGER
  configRS232PortName DisplayString
  configRS232BaudRate INTEGER
  configRS232ModemStatus INTEGER
  configRS232ConnectionStatus INTEGER
  configRS232ModemConfigString DisplayString
  configRS232OutputData OCTET STRING Size(0..42)
  configRS232InputData OCTET STRING Size(0..100)
  configRS232HardwareFlowControl INTEGER

SecurityMacAddressTableEntry  
SEQUENCE    
  securityMacAddress OCTET STRING
  securityStatus INTEGER
  securityLockoutCount Counter

TrHistoryEntry  
SEQUENCE    
  trHistoryIndex INTEGER 1..65535
  trHistorySampleIndex INTEGER
  trHistoryIntervalStart TimeTicks
  trHistoryInPkts Counter
  trHistoryOutPkts Counter
  trHistoryInOctets Counter
  trHistoryOutOctets Counter
  trHistoryOutBroadcastPkts Counter
  trHistoryOutMulticastPkts Counter
  trHistoryClaimTokenPkts Counter
  trHistoryInLineErrors Counter
  trHistoryOutLineErrors Counter
  trHistoryInternalErrors Counter
  trHistoryInBurstErrors Counter
  trHistoryOutBurstErrors Counter
  trHistoryACErrors Counter
  trHistoryAbortErrors Counter
  trHistoryLostFrameErrors Counter
  trHistoryCongestionErrors Counter
  trHistoryFrameCopiedErrors Counter
  trHistoryFrequencyErrors Counter
  trHistoryTokenErrors Counter
  trHistoryInBeaconErrors Counter
  trHistoryOutBeaconErrors Counter
  trHistoryInsertions Counter
  trHistorySoftErrors Counter

TrHistoryOpaqueEntry  
SEQUENCE    
  trHistoryTableData Opaque

ProtocolStatsEntry  
SEQUENCE    
  protocolIfIndex INTEGER 1..65535
  protocolID INTEGER 1..65535
  protocolPkts Counter
  protocolOctets Counter

Defined Values

startek 1.3.6.1.4.1.260
OBJECT IDENTIFIER    

products 1.3.6.1.4.1.260.1
OBJECT IDENTIFIER    

maintenance 1.3.6.1.4.1.260.2
OBJECT IDENTIFIER    

fSeries 1.3.6.1.4.1.260.1.2
OBJECT IDENTIFIER    

stackable 1.3.6.1.4.1.260.1.3
OBJECT IDENTIFIER    

m828Series 1.3.6.1.4.1.260.1.1
OBJECT IDENTIFIER    

m828Hubs 1.3.6.1.4.1.260.1.1.1
OBJECT IDENTIFIER    

m828HubNumber 1.3.6.1.4.1.260.1.1.1.1
The number of items in hub table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

m828HubTable 1.3.6.1.4.1.260.1.1.1.2
A table which maintains a list of all of the intelligent m828 series hubs on the ring being managed by the addressed agent. This table is indexed by the RS485 OOB address of the m828 series intelligent hubs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    M828hubTableEntry

m828HubTableEntry 1.3.6.1.4.1.260.1.1.1.2.1
An entry in the m828HubTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  M828hubTableEntry  

m828HubTableIndex 1.3.6.1.4.1.260.1.1.1.2.1.1
The index for this hub entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

m828HubModel 1.3.6.1.4.1.260.1.1.1.2.1.2
The model number of the m828 series hub being managed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER model-4(1), model-5(2), model-6(3), model-7(4)  

m828Hub485Address 1.3.6.1.4.1.260.1.1.1.2.1.3
The 4 hex digit address used on the RS485 serial OOB management channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2..2)  

m828HubRiFTolSw 1.3.6.1.4.1.260.1.1.1.2.1.4
The status of the Ring In fault tolerance switch on the front panel of the hub.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

m828HubRiFTolState 1.3.6.1.4.1.260.1.1.1.2.1.5
This parameter controls the Ring In (RI) fault tolerance behavior. The default value for this parameter is the same setting as is present for m828HubRiFTolSw. SETTING this parameter overrides the value derived from m828HubRiFTolSw. Off(1) means that phantom currentis not used on the corresponding RI interface as a condition for main ring link insertion. On (2) means that phantom current is used on the corresponding RI interface as a condition for main ring link insertion. The preffered setting for this parameter is on (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

m828HubRiMask 1.3.6.1.4.1.260.1.1.1.2.1.6
Administrative status for this Ring In port. By setting this parameter, a remote manager can control the partitioning of this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER isolate(1), enable(2)  

m828HubRiPhDet 1.3.6.1.4.1.260.1.1.1.2.1.7
This parameter describes the phantom detect status for this Ring In port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noPhantom(1), phantDetected(2)  

m828HubRiNsrtStatus 1.3.6.1.4.1.260.1.1.1.2.1.8
Insertion status for this Ring In port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bypassed(1), inserted(2)  

m828HubRiBcnRemStatus 1.3.6.1.4.1.260.1.1.1.2.1.9
This parameter describes the result of any automatic beacon removal operations performed by the agent on this port. Automatic beacon removal operations consist of agent-initiated isolation of a lobe port in order to remove the cause of a persistent beaconing condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), autoIsolated(2)  

m828RiNeighborType 1.3.6.1.4.1.260.1.1.1.2.1.10
This parameter indicates the type of nearest neighbor on the Ring In port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER series828(1), fSeries(2), tokenRingMAC(3), none(4), stackable(5)  

m828RiNeighborAddr 1.3.6.1.4.1.260.1.1.1.2.1.11
The address of the nearest neighbor on the Ring In port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2..6)  

m828RiTimeStamp 1.3.6.1.4.1.260.1.1.1.2.1.12
The time the status of Ring In (was) last changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

m828HubRoFTolSw 1.3.6.1.4.1.260.1.1.1.2.1.13
The state of the Ring Out Fault Tolerance switch on the front panel of the unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

m828HubRoFTolState 1.3.6.1.4.1.260.1.1.1.2.1.14
This parameter controls the Ring Out(RO) fault tolerance behavior. The default value for this parameter is the same setting as is present for m828HubRoFTolSw. SETTING this parameter overrides the value derived from m828HubRoFTolSw. Off(1) means that phantom currentis not used on the corresponding RO interface as a condition for main ring link insertion. On (2) means that phantom current is used on the corresponding RO interface as a condition for main ring link insertion. The preffered setting for this parameter is on (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

m828HubRoMask 1.3.6.1.4.1.260.1.1.1.2.1.15
Administrative status for this Ring Out port. By setting this parameter, a remote manager can control the partitioning of this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER isolate(1), enable(2)  

m828HubRoPhDet 1.3.6.1.4.1.260.1.1.1.2.1.16
This parameter describes the phantom detect status for this Ring Out port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wireFault(1), phantOk(2)  

m828HubRoNsrtStatus 1.3.6.1.4.1.260.1.1.1.2.1.17
Insertion status for this Ring Out port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bypassed(1), inserted(2)  

m828HubRoBcnRemStatus 1.3.6.1.4.1.260.1.1.1.2.1.18
This parameter describes the result of any automatic beacon removal operations performed by the agent on this port. Automatic beacon removal operations consist of agent-initiated isolation of a lobe port in order to remove the cause of a persistent beaconing condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), autoIsolated(2)  

m828RoNeighborType 1.3.6.1.4.1.260.1.1.1.2.1.19
This parameter indicates the type of nearest neighbor on the Ring Out port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER series828(1), fSeries(2), tokenRingMAC(3), none(4), stackable(5)  

m828RoNeighborAddr 1.3.6.1.4.1.260.1.1.1.2.1.20
The address of the nearest neighbor on the Ring Out port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2..6)  

m828RoTimeStamp 1.3.6.1.4.1.260.1.1.1.2.1.21
The time the status of Ring Out (was) last changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

m828HubDataRateSwitch 1.3.6.1.4.1.260.1.1.1.2.1.22
Setting of this parameter changes the data rate of this unit. A value of noSwitch(3) indicates that the setting of the data rate is not available on this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER s4Mbps(1), s16Mbps(2), noSwitch(3)  

m828HubDataRateState 1.3.6.1.4.1.260.1.1.1.2.1.23
This parameter indicates the current data rate of this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s4Mbps(1), s16Mbps(2), autoConfig(3)  

m828HubDataRateTimeStamp 1.3.6.1.4.1.260.1.1.1.2.1.24
The time the data rate status (was) last changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

m828HubMgmtStatus 1.3.6.1.4.1.260.1.1.1.2.1.25
The operational status of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER operational(1), down(2)  

m828HubProxyAgentID 1.3.6.1.4.1.260.1.1.1.2.1.26
The physical layer MAC Address of the agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6..6)  

m828HubCodeVersion 1.3.6.1.4.1.260.1.1.1.2.1.27
The firmware version number of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2..2)  

m828HubRawCommandData 1.3.6.1.4.1.260.1.1.1.2.1.28
This is used to send raw 485 serial data to this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..1)  

m828HubLobeNumber 1.3.6.1.4.1.260.1.1.1.3
The number of items in the hub lobe table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

m828HubLobeTable 1.3.6.1.4.1.260.1.1.1.4
A table which contains the control and status information for the lobes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    M828hubLobeEntry

m828HubLobeEntry 1.3.6.1.4.1.260.1.1.1.4.1
A collection of control and status parameters kept for each lobe.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  M828hubLobeEntry  

m828HubIndex 1.3.6.1.4.1.260.1.1.1.4.1.1
The index into the m828HubTable of the mau this lobe is on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

m828HubLobePort 1.3.6.1.4.1.260.1.1.1.4.1.2
The port of the mau this lobe is on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

m828HubLobePhDet 1.3.6.1.4.1.260.1.1.1.4.1.3
Phantom current status for this lobe port. A value of 1 corresponds to no phantom current detected. A value of 2 corresponds to phantom presence.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noPhantom(1), phantDetected(2)  

m828HubLobeMask 1.3.6.1.4.1.260.1.1.1.4.1.4
Administrative status for this lobe port. By setting this parameter, a remote manager can control access to the lobe port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER isolated(1), enabled(2)  

m828HubLobeNsrtStatus 1.3.6.1.4.1.260.1.1.1.4.1.5
Actual insertion status for this lobe port. A 1 value means that the corresponding station is not connected to the ring. A 2 value means that the corresponding station is connected to the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bypassed(1), inserted(2)  

m828HubLobeMacAddr 1.3.6.1.4.1.260.1.1.1.4.1.6
The MAC layer address of the station which is attached to the corresponding lobe port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6..6)  

m828HubLobeBcnRemStatus 1.3.6.1.4.1.260.1.1.1.4.1.7
This parameter describes the result of any automatic beacon removal operations performed by the agent on this port. Automatic beacon removal operations consist of agent-initiated isolation of a lobe port in order to remove the cause of a persistent beaconing condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), autoIsolated(2), unknown(3)  

m828HubLobeTimeStamp 1.3.6.1.4.1.260.1.1.1.4.1.8
The time the status of this lobe (was) last changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fChassis 1.3.6.1.4.1.260.1.2.1
OBJECT IDENTIFIER    

fTRMainRing 1.3.6.1.4.1.260.1.2.2
OBJECT IDENTIFIER    

fTRLobe 1.3.6.1.4.1.260.1.2.3
OBJECT IDENTIFIER    

fEthernet 1.3.6.1.4.1.260.1.2.4
OBJECT IDENTIFIER    

fFddi 1.3.6.1.4.1.260.1.2.5
OBJECT IDENTIFIER    

fTwx 1.3.6.1.4.1.260.1.2.6
OBJECT IDENTIFIER    

fChassisNumber 1.3.6.1.4.1.260.1.2.1.1
The number of chassis in table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fChassisTable 1.3.6.1.4.1.260.1.2.1.2
A table which describes which modules are plugged into which slots of the chassis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FchassisTableEntry

fChassisTableEntry 1.3.6.1.4.1.260.1.2.1.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FchassisTableEntry  

fChassisIndex 1.3.6.1.4.1.260.1.2.1.2.1.1
Index of this entry
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fChassisModel 1.3.6.1.4.1.260.1.2.1.2.1.2
The model number of the f series chassis in which the addressed management agent is installed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER twoslot-10100(1), fiveslot-10101(2), fiveslotredundant-10102(3), reserved4(4), reserved5(5), reserved6(6), reserved7(7), reserved8(8)  

fChassisPowStatus 1.3.6.1.4.1.260.1.2.1.2.1.3
The status of the power supply or supplies in the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER singleSupOK(1), dualSupOK(2), dualSup-BSupBAD(3), dualSup-ASupBAD(4), illegal(5)  

fChassisLocation 1.3.6.1.4.1.260.1.2.1.2.1.4
The location of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER local(1), external(2)  

fTRMainRingNumber 1.3.6.1.4.1.260.1.2.2.1
The number of the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fTRMainRingTable 1.3.6.1.4.1.260.1.2.2.2
A table which maintains a list of all of the intelligent Focus series hubs on the ring being managed by the addressed agent. This table is INDEXed by the RS485 OOB address of the Focus series intelligent hubs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FTRMainRingTableEntry

fTRMainRingTableEntry 1.3.6.1.4.1.260.1.2.2.2.1
An entry in the fTRMainRingTable
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FTRMainRingTableEntry  

fTRMainRingTableIndex 1.3.6.1.4.1.260.1.2.2.2.1.1
The index for this ring entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fTRMainRingModel 1.3.6.1.4.1.260.1.2.2.2.1.2
The model number of the Focus series hub being managed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f10154RiRoExpModule(1), f10155RiRoFiberExpModule(2), f10150RiRoExpModuleAgent(3), f10151RiRoFiberExpModuleAgent(4)  

fTRMainRing485Address 1.3.6.1.4.1.260.1.2.2.2.1.3
The 6 hex digit address used on the RS485 serial OOB management channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3..3)  

fTRMainRingSlotIndex 1.3.6.1.4.1.260.1.2.2.2.1.4
The slot id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fTRMainRingChassisIndex 1.3.6.1.4.1.260.1.2.2.2.1.5
The index of the chassis the card is in.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fTRMainRingRiFTolState 1.3.6.1.4.1.260.1.2.2.2.1.6
This parameter controls the Ring In (RI) fault tolerance behavior. Off(1) means that phantom current is not used on the corresponding RI interface as a condition for main ring link insertion. On (2) means that phantom current is used on the corresponding RI interface as a condition for main ring link insertion. The preferred setting for this parameter is on (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fTRMainRingRiMask 1.3.6.1.4.1.260.1.2.2.2.1.7
Administrative status for this Ring In port. By setting this parameter, a remote manager can control the partitioning of this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER isolate(1), enable(2)  

fTRMainRingRiPhDet 1.3.6.1.4.1.260.1.2.2.2.1.8
This parameter describes the phantom detect status of the Ring In port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noPhantom(1), phantDetected(2)  

fTRMainRingRiNsrtStatus 1.3.6.1.4.1.260.1.2.2.2.1.9
Insertion status for this Ring In port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bypassed(1), inserted(2)  

fTRMainRingRiBcnRemStatus 1.3.6.1.4.1.260.1.2.2.2.1.10
This parameter describes the result of any automatic beacon removal operations performed by the agent on this port. Automatic beacon removal operations consist of agent-initiated isolation of a lobe port in order to remove the cause of a persistent beaconing condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), autoIsolated(2)  

fTRMainRingRiCableType 1.3.6.1.4.1.260.1.2.2.2.1.11
This parameter indicates the type of physical cabling used for the network interface on the Ring In port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER copper(1), fiber(2)  

fTRMainRingRiNghbrType 1.3.6.1.4.1.260.1.2.2.2.1.12
This parameter indicates the type of nearest neighbor on the Ring In port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER series828(1), fSeries(2), tokenRingMAC(3), none(4), stackable(5)  

fTRMainRingRiNghbrAddr 1.3.6.1.4.1.260.1.2.2.2.1.13
The address of the nearest neighbor on the Ring In port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2..6)  

fTRMainRingRiTimeStamp 1.3.6.1.4.1.260.1.2.2.2.1.14
The time the status of Ring In (was) last changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fTRMainRingRoFTolState 1.3.6.1.4.1.260.1.2.2.2.1.15
This controls the Ring Out (RO) fault tolerance behavior. Off(1) means that phantom current is not used on the corresponding RO interface as a condition for main ring link insertion. On (2) means tha phantom current is used on the corresponding RO interface as a condition for main ring link insertion. The preferred setting for this parameter is on (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

fTRMainRingRoMask 1.3.6.1.4.1.260.1.2.2.2.1.16
Administrative status for this Ring Out port. By setting this parameter, a remote manager can control the partitioning of this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER isolate(1), enable(2)  

fTRMainRingRoPhDet 1.3.6.1.4.1.260.1.2.2.2.1.17
This parameter describes the phantom detect status for this Ring Out port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wireFault(1), phantOk(2)  

fTRMainRingRoNsrtStatus 1.3.6.1.4.1.260.1.2.2.2.1.18
Insertion status for this Ring Out port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bypassed(1), inserted(2)  

fTRMainRingRoBcnRemStatus 1.3.6.1.4.1.260.1.2.2.2.1.19
This parameter describes the result of any automatic beacon removal operations performed by the agent on this port. Automatic beacon removal operations consist of agent-initiated isolation of a lobe port in order to remove the cause of a persistent beaconing condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), autoIsolated(2)  

fTRMainRingRoCableType 1.3.6.1.4.1.260.1.2.2.2.1.20
This parameter indicates the type of physical cabling used for the network interface on the Ring Out port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER copper(1), fiber(2)  

fTRMainRingRoNghbrType 1.3.6.1.4.1.260.1.2.2.2.1.21
This parameter indicates the type of nearest neighbor on the Ring Out port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER series828(1), fSeries(2), tokenRingMAC(3), none(4), stackable(5)  

fTRMainRingRoNghbrAddr 1.3.6.1.4.1.260.1.2.2.2.1.22
The address of the nearest neighbor on the Ring Out port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2..6)  

fTRMainRingRoTimeStamp 1.3.6.1.4.1.260.1.2.2.2.1.23
The time the status of Ring Out (was) last changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fTRMainRingDataRateState 1.3.6.1.4.1.260.1.2.2.2.1.24
This parameter indicates the current data rate of this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s4Mbps(1), s16Mbps(2)  

fTRMainRingDataRateTimeStamp 1.3.6.1.4.1.260.1.2.2.2.1.25
The time the data rate status (was) last changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fTRMainRingBkPlnNsrtState 1.3.6.1.4.1.260.1.2.2.2.1.26
Backplane insertion status for this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inserted(1), bypassed(2)  

fTRMainRingBkPlnTimeStamp 1.3.6.1.4.1.260.1.2.2.2.1.27
The time the backplane insert status (was) last changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fTRMainRingLobePhDet 1.3.6.1.4.1.260.1.2.2.2.1.28
Phantom current status for this lobe port. A value of 1 corresponds to no phantom current detected. A value of 2 corresponds to phantom presence.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noPhantom(1), phantDetected(2)  

fTRMainRingLobeMask 1.3.6.1.4.1.260.1.2.2.2.1.29
Administrative status for this lobe port. By setting this parameter, a remote manager can control access to the lobe port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER isolated(1), enabled(2)  

fTRMainRingLobeNsrtStatus 1.3.6.1.4.1.260.1.2.2.2.1.30
Actual insertion status for this lobe port. A 1 value means that the corresponding station is not connected to the ring. A 2 value means that the corresponding station is connected to the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bypassed(1), inserted(2)  

fTRMainRingLobeMacAddr 1.3.6.1.4.1.260.1.2.2.2.1.31
The MAC layer address of the station which is attached to the corresponding lobe port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6..6)  

fTRMainRingLobeBcnRemStatus 1.3.6.1.4.1.260.1.2.2.2.1.32
This parameter describes the result of any automatic beacon removal operations performed by the agent on this port. Automatic beacon removal operations consist of agent-initiated isolation of a lobe port in order to remove the cause of a persistent beaconing condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), autoIsolated(2), unknown(3)  

fTRMainRingLobeTimeStamp 1.3.6.1.4.1.260.1.2.2.2.1.33
The time the status of this lobe (was) last changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fTRMainRingMgmtStatus 1.3.6.1.4.1.260.1.2.2.2.1.34
The operational status of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER operational(1), down(2)  

fTRMainRingProxyAgentID 1.3.6.1.4.1.260.1.2.2.2.1.35
The physical layer MAC Address of the agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6..6)  

fTRMainRingAttachedAgentType 1.3.6.1.4.1.260.1.2.2.2.1.36
The type of the attached agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER tokenring(1), tokenring-ethernet(2), reserved(3), none(4)  

fTRMainRingAttachedAgentState 1.3.6.1.4.1.260.1.2.2.2.1.37
The state of the attached agent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), not-applicable(3)  

fTRMainRingTemperatureStatus 1.3.6.1.4.1.260.1.2.2.2.1.38
The temperature status of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), bad(2)  

fTRMainRingAutoRecovControl 1.3.6.1.4.1.260.1.2.2.2.1.39
This parameter controls the auto recovery operation of this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), reset(3), unknown(4)  

fTRMainRingAutoRecovRetries 1.3.6.1.4.1.260.1.2.2.2.1.40
The number of Auto Recoveries performed by this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fTRMainRingCodeVersion 1.3.6.1.4.1.260.1.2.2.2.1.41
The firmware version number of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2..2)  

fTRMainRingAutoRecovState 1.3.6.1.4.1.260.1.2.2.2.1.42
The auto recovery state of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER in-recovery(1), normal(2), halted(3)  

fTRMainRingRawCommandData 1.3.6.1.4.1.260.1.2.2.2.1.43
This is used to send raw 485 serial data to this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..255)  

fTRMainRingPowerStatus 1.3.6.1.4.1.260.1.2.2.2.1.44
The status of the power supply as seen by this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER singleSupOK(1), dualSupOK(2), dualSup-BSupBAD(3), dualSup-ASupBAD(4), illegal(5)  

fTRMainRingCageType 1.3.6.1.4.1.260.1.2.2.2.1.45
The model number of the f series chassis the card is is.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER twoslot-10100(1), fiveslot-10101(2), fiveslotredundant-10102(3), reserved4(4), reserved5(5), reserved6(6), reserved7(7), reserved8(8)  

fTRMainRingAutoRecovMode 1.3.6.1.4.1.260.1.2.2.2.1.46
This parameter describes the auto recovery mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER selfEnabling(1), non-selfEnabling(2)  

fTRLobeNumber 1.3.6.1.4.1.260.1.2.3.1
The number of items in the lobe table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fTRLobeTable 1.3.6.1.4.1.260.1.2.3.2
A table which maintains a list of all of the intelligent Focus series hubs on the ring being managed by the addressed agent. This table is INDEXed by the RS485 OOB address of the Focus series intelligent hubs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FTRLobeTableEntry

fTRLobeTableEntry 1.3.6.1.4.1.260.1.2.3.2.1
An entry in the fTRLobeTable
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FTRLobeTableEntry  

fTRLobeTableIndex 1.3.6.1.4.1.260.1.2.3.2.1.1
The index for this lobe entry
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fTRLobeModel 1.3.6.1.4.1.260.1.2.3.2.1.2
The Mau type of the Focus series lobe being managed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f10157trPassiveMau(1), f10158trActiveMau(2)  

fTRLobe485Address 1.3.6.1.4.1.260.1.2.3.2.1.3
The 6 hex digit address used on the RS485 serial OOB management channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3..3)  

fTRLobeSlotIndex 1.3.6.1.4.1.260.1.2.3.2.1.4
The slot id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fTRLobeChassisIndex 1.3.6.1.4.1.260.1.2.3.2.1.5
The index of the chassis the card is in.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fTRLobeDataRateState 1.3.6.1.4.1.260.1.2.3.2.1.6
This parameter indicates the current data rate of this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s4Mbps(1), s16Mbps(2)  

fTRLobeDataRateTimeStamp 1.3.6.1.4.1.260.1.2.3.2.1.7
The time the data rate status (was) last changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fTRLobeBkPlnNsrtState 1.3.6.1.4.1.260.1.2.3.2.1.8
Backplane insertion status for this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inserted(1), bypassed(2)  

fTRLobeBkPlnTimeStamp 1.3.6.1.4.1.260.1.2.3.2.1.9
The time the backplane insert status (was) last changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fTRLobeMgmtStatus 1.3.6.1.4.1.260.1.2.3.2.1.10
The operational status of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER operational(1), down(2)  

fTRLobeProxyAgentID 1.3.6.1.4.1.260.1.2.3.2.1.11
The physical layer MAC Address of the agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6..6)  

fTRLobeTemperatureStatus 1.3.6.1.4.1.260.1.2.3.2.1.12
The temperature status of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), bad(2)  

fTRLobeAutoRecovControl 1.3.6.1.4.1.260.1.2.3.2.1.13
This parameter controls the auto recovery operation of this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), reset(3)  

fTRLobeAutoRecovMode 1.3.6.1.4.1.260.1.2.3.2.1.14
This parameter describes the auto recovery mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER selfEnabling(1), non-selfEnabling(2)  

fTRLobeAutoRecovRetries 1.3.6.1.4.1.260.1.2.3.2.1.15
The number of Auto Recoveries performed by this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

fTRLobeCodeVersion 1.3.6.1.4.1.260.1.2.3.2.1.16
The firmware version number of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2..2)  

fTRLobeAutoRecovState 1.3.6.1.4.1.260.1.2.3.2.1.17
The auto recovery state of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER in-recovery(1), normal(2), halted(3)  

fTRLobeRawCommandData 1.3.6.1.4.1.260.1.2.3.2.1.18
This is used to send raw 485 serial data to this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..255)  

fTRLobePowerStatus 1.3.6.1.4.1.260.1.2.3.2.1.19
The status of the power supply as seen by this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER singleSupOK(1), dualSupOK(2), dualSup-BSupBAD(3), dualSup-ASupBAD(4), illegal(5)  

fTRLobeCageType 1.3.6.1.4.1.260.1.2.3.2.1.20
The model number of the fseries chassis the card is is.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER twoslot-10100(1), fiveslot-10101(2), fiveslotredundant-10102(3), reserved4(4), reserved5(5), reserved6(6), reserved7(7), reserved8(8)  

fTRLobeConnectNumber 1.3.6.1.4.1.260.1.2.3.3
The number of items in connection table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fTRLobeConnectTable 1.3.6.1.4.1.260.1.2.3.4
A table which contains the control and status information for the lobes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FTRLobeConnectEntry

fTRLobeConnectEntry 1.3.6.1.4.1.260.1.2.3.4.1
A collection of control and status parameters kept for each lobe.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FTRLobeConnectEntry  

fTRLobeIndex 1.3.6.1.4.1.260.1.2.3.4.1.1
The index into the fTRLobeTable of the mau this lobe is on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fTRLobeConnectPort 1.3.6.1.4.1.260.1.2.3.4.1.2
The port of the mau this lobe is on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fTRLobeConnectPhDet 1.3.6.1.4.1.260.1.2.3.4.1.3
Phantom current status for this lobe port. A value of 1 corresponds to no phantom current detected. A value of 2 corresponds to phantom presence.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noPhantom(1), phantDetected(2)  

fTRLobeConnectMask 1.3.6.1.4.1.260.1.2.3.4.1.4
Administrative status for this lobe port. By setting this parameter, a remote manager can control access to the lobe port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER isolated(1), enabled(2)  

fTRLobeConnectNsrtStatus 1.3.6.1.4.1.260.1.2.3.4.1.5
Actual insertion status for this lobe port. A 1 value means that the corresponding station is not connected to the ring. A 2 value means that the corresponding station is connected to the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bypassed(1), inserted(2)  

fTRLobeConnectMacAddr 1.3.6.1.4.1.260.1.2.3.4.1.6
The MAC layer address of the station which is attached to the corresponding lobe port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6..6)  

fTRLobeConnectBcnRemStatus 1.3.6.1.4.1.260.1.2.3.4.1.7
This parameter describes the result of any automatic beacon removal operations performed by the agent on this port. Automatic beacon removal operations consist of agent-initiated isolation of a lobe port in order to remove the cause of a persistent beaconing condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), autoIsolated(2), unknown(3)  

fTRLobeConnectBcnRemCause 1.3.6.1.4.1.260.1.2.3.4.1.8
This parameter describes the cause of any automatic beacon removal
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no-removal(1), phantom-error(2), no-carrier(3), bad-rate(4), unknown(5)  

fTRLobeConnectTimeStamp 1.3.6.1.4.1.260.1.2.3.4.1.9
The time the status of this lobe (was) last changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fEthernetNumber 1.3.6.1.4.1.260.1.2.4.1
The number of items in concentrator table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fEthernetTable 1.3.6.1.4.1.260.1.2.4.2
A table which maintains a list of all of the Focus series ethernet concentrators in the repeater being managed by the addressed agent. This table is INDEXed by the repeater group id of the Focus series ethernet concentrators.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FEthernetTableEntry

fEthernetTableEntry 1.3.6.1.4.1.260.1.2.4.2.1
An entry in the fEthernetTable
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FEthernetTableEntry  

fEthernetTableIndex 1.3.6.1.4.1.260.1.2.4.2.1.1
The index for this hub entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fEthernetModel 1.3.6.1.4.1.260.1.2.4.2.1.2
The model number of the Focus series ethernet concentrator being managed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f10160(1), f10161(2)  

fEthernet485Address 1.3.6.1.4.1.260.1.2.4.2.1.3
The 6 hex digit address used on the RS485 serial OOB management channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3..3)  

fEthernetSlotIndex 1.3.6.1.4.1.260.1.2.4.2.1.4
The slot id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fEthernetChassisIndex 1.3.6.1.4.1.260.1.2.4.2.1.5
The index of the chassis the card is in.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fEthernetBkPlnNsrtState 1.3.6.1.4.1.260.1.2.4.2.1.6
Backplane insertion status for this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inserted(1), bypassed(2)  

fEthernetBkPlnTimeStamp 1.3.6.1.4.1.260.1.2.4.2.1.7
The time the backplane insert status (was) last changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

fEthernetMgmtStatus 1.3.6.1.4.1.260.1.2.4.2.1.8
The operational status of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER operational(1), down(2)  

fEthernetProxyAgentID 1.3.6.1.4.1.260.1.2.4.2.1.9
The physical layer MAC Address of the agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6..6)  

fEthernetTemperatureStatus 1.3.6.1.4.1.260.1.2.4.2.1.10
The temperature status of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), bad(2)  

fEthernetCodeVersion 1.3.6.1.4.1.260.1.2.4.2.1.11
The firmware version number of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2..2)  

fEthernetRawCommandData 1.3.6.1.4.1.260.1.2.4.2.1.12
This is used to send raw 485 serial data to this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..255)  

fEthernetPowerStatus 1.3.6.1.4.1.260.1.2.4.2.1.13
The status of the power supply as seen by this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER singleSupOK(1), dualSupOK(2), dualSup-BSupBAD(3), dualSup-ASupBAD(4), illegal(5)  

fEthernetCageType 1.3.6.1.4.1.260.1.2.4.2.1.14
The model number of the fseries chassis the card is is.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER twoslot-10100(1), fiveslot-10101(2), fiveslotredundant-10102(3), reserved4(4), reserved5(5), reserved6(6), reserved7(7), reserved8(8)  

rmonAgent 1.3.6.1.4.1.260.1.2.7
OBJECT IDENTIFIER    

rmonAgentDescription 1.3.6.1.4.1.260.1.2.7.1
The text name for this agent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

rmonAgentID 1.3.6.1.4.1.260.1.2.7.2
The text name for this agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6..6)  

rmonAgentOOBNumber 1.3.6.1.4.1.260.1.2.7.3
The number of items in connection table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rmonAgentOOBTable 1.3.6.1.4.1.260.1.2.7.4
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RmonAgentOOBTableEntry

rmonAgentOOBTableEntry 1.3.6.1.4.1.260.1.2.7.4.1
An entry in the rmonAgentOOBTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  RmonAgentOOBTableEntry  

rmonAgentOOBTableIndex 1.3.6.1.4.1.260.1.2.7.4.1.1
The index of this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rmonAgentOOBTableDescription 1.3.6.1.4.1.260.1.2.7.4.1.2
The text description of this OOB (Out Of Band) table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

rmonAgentOOBTableData 1.3.6.1.4.1.260.1.2.7.4.1.3
An opaque data structure used for management.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Opaque  

rmonAgentOOBRawDataCommand 1.3.6.1.4.1.260.1.2.7.4.1.4
Raw method of sending data on channel.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..255)  

rmonAgentIBNumber 1.3.6.1.4.1.260.1.2.7.5
The number of items in the connection table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rmonAgentIBTable 1.3.6.1.4.1.260.1.2.7.6
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RmonAgentIBTableEntry

rmonAgentIBTableEntry 1.3.6.1.4.1.260.1.2.7.6.1
An entry in the rmonAgentIBTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  RmonAgentIBTableEntry  

rmonAgentIBTableIndex 1.3.6.1.4.1.260.1.2.7.6.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rmonAgentIBTableDescription 1.3.6.1.4.1.260.1.2.7.6.1.2
The text description of this IB (In Band) Table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

rmonAgentIBNetworkType 1.3.6.1.4.1.260.1.2.7.6.1.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER tokenring(1), ethernet(2), fddi(3)  

rmonAgentIBSampleInterval 1.3.6.1.4.1.260.1.2.7.6.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

rmonAgentIBMacFrames 1.3.6.1.4.1.260.1.2.7.6.1.5
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmonAgentIBDataFrames 1.3.6.1.4.1.260.1.2.7.6.1.6
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmonAgentIBMacBytes 1.3.6.1.4.1.260.1.2.7.6.1.7
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmonAgentIBDataBytes 1.3.6.1.4.1.260.1.2.7.6.1.8
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmonAgentIBUtilization 1.3.6.1.4.1.260.1.2.7.6.1.9
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmonAgentIBMACUtilization 1.3.6.1.4.1.260.1.2.7.6.1.10
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmonAgentIBNonMACUtilization 1.3.6.1.4.1.260.1.2.7.6.1.11
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmonAgentIBMACData0 1.3.6.1.4.1.260.1.2.7.6.1.12
An opaque data structure used for management.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Opaque  

rmonAgentIBMACData1 1.3.6.1.4.1.260.1.2.7.6.1.13
An opaque data structure used for management.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Opaque  

rmonAgentIBMACData2 1.3.6.1.4.1.260.1.2.7.6.1.14
An opaque data structure used for management.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Opaque  

rmonAgentIBMACData3 1.3.6.1.4.1.260.1.2.7.6.1.15
An opaque data structure used for management.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Opaque  

rmonAgentIBMACData4 1.3.6.1.4.1.260.1.2.7.6.1.16
An opaque data structure used for management.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Opaque  

rmonAgentIBMACData5 1.3.6.1.4.1.260.1.2.7.6.1.17
An opaque data structure used for management.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Opaque  

rmonAgentIBMACData6 1.3.6.1.4.1.260.1.2.7.6.1.18
An opaque data structure used for management.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Opaque  

rmonAgentIBMACData7 1.3.6.1.4.1.260.1.2.7.6.1.19
An opaque data structure used for management.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Opaque  

rmonAgentIBMACData8 1.3.6.1.4.1.260.1.2.7.6.1.20
An opaque data structure used for management.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Opaque  

rmonAgentIBMACData9 1.3.6.1.4.1.260.1.2.7.6.1.21
An opaque data structure used for management.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Opaque  

rmonAgentIBMACData10 1.3.6.1.4.1.260.1.2.7.6.1.22
An opaque data structure used for management.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Opaque  

rmonAgentIBMACData11 1.3.6.1.4.1.260.1.2.7.6.1.23
An opaque data structure used for management.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Opaque  

rmonAgentMonitorCommand 1.3.6.1.4.1.260.1.2.7.7
A method of sending raw commands to the agent monitor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

rmonAgentMonitorResponse 1.3.6.1.4.1.260.1.2.7.8
This parameter contains the text response to an agent monitor command.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..1024)  

rmonAgentDownloadData 1.3.6.1.4.1.260.1.2.7.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

rmonAgentNoMapOid 1.3.6.1.4.1.260.1.2.7.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OBJECT IDENTIFIER  

rmonAgentMACStatTable 1.3.6.1.4.1.260.1.2.7.11
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RmonAgentMACStatTableEntry

rmonAgentMACStatTableEntry 1.3.6.1.4.1.260.1.2.7.11.1
An entry in the rmonAgentIBTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  RmonAgentMACStatTableEntry  

rmonAgentMACStatTableData 1.3.6.1.4.1.260.1.2.7.11.1.1
An opaque data structure used for management.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Opaque  

rmonAgentIPAdressControl 1.3.6.1.4.1.260.1.2.7.12
An opaque data structure used for management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Opaque  

stackableHubs 1.3.6.1.4.1.260.1.3.1
OBJECT IDENTIFIER    

stackableHubNumber 1.3.6.1.4.1.260.1.3.1.1
The number of items in hub table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

stackableHubTable 1.3.6.1.4.1.260.1.3.1.2
A table which maintains a list of all of the intelligent stackable series hubs on the ring being managed by the addressed agent. This table is indexed by the RS485 OOB address of the stackable series intelligent hubs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StackablehubTableEntry

stackableHubTableEntry 1.3.6.1.4.1.260.1.3.1.2.1
An entry in the stackableHubTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  StackablehubTableEntry  

stackableHubTableIndex 1.3.6.1.4.1.260.1.3.1.2.1.1
The index for this hub entry
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

stackableHubModel 1.3.6.1.4.1.260.1.3.1.2.1.2
The model number of the stackable series hub being managed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER standard-issue(1)  

stackableHub485Address 1.3.6.1.4.1.260.1.3.1.2.1.3
The 6 hex digit address used on the RS485 serial OOB management channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3..3)  

stackableHubRiFTolState 1.3.6.1.4.1.260.1.3.1.2.1.4
This parameter controls the Ring In (RI) fault tolerance behavior. Off(1) means that phantom current is not used on the corresponding RI interface as a condition for main ring link insertion. On (2) means tha phantom current is used on the corresponding RI interface as a condition for main ring link insertion. The preferred setting for this parameter is on (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

stackableHubRiMask 1.3.6.1.4.1.260.1.3.1.2.1.5
Administrative status for this Ring In port. By setting this parameter, a remote manager can control the partitioning of this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER isolate(1), enable(2)  

stackableHubRiPhDet 1.3.6.1.4.1.260.1.3.1.2.1.6
This parameter describes the phantom detect status for this Ring In port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noPhantom(1), phantDetected(2)  

stackableHubRiNsrtStatus 1.3.6.1.4.1.260.1.3.1.2.1.7
Insertion status for this Ring In port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bypassed(1), inserted(2)  

stackableHubRiBcnRemStatus 1.3.6.1.4.1.260.1.3.1.2.1.8
This parameter describes the result of any automatic beacon removal operations performed by the agent on this port. Automatic beacon removal operations consist of agent-initiated isolation of a lobe port in order to remove the cause of a persistent beaconing condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), autoIsolated(2)  

stackableHubRiNeighborType 1.3.6.1.4.1.260.1.3.1.2.1.9
This parameter indicates the type of nearest neighbor on the Ring In port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER series828(1), fSeries(2), tokenRingMAC(3), none(4), stackable(5)  

stackableHubRiNeighborAddr 1.3.6.1.4.1.260.1.3.1.2.1.10
The address of the nearest neighbor on the Ring In port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2..6)  

stackableHubRiTimeStamp 1.3.6.1.4.1.260.1.3.1.2.1.11
The time the status of Ring In (was) last changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

stackableHubRoFTolState 1.3.6.1.4.1.260.1.3.1.2.1.12
This parameter controls the Ring Out(RO) fault tolerance behavior. Off(1) means that phantom current is not used on the corresponding RO interface as a condition for main ring link insertion. On (2) means tha phantom current is used on the corresponding RO interface as a condition for main ring link insertion. The preferred setting for this parameter is on (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

stackableHubRoMask 1.3.6.1.4.1.260.1.3.1.2.1.13
Administrative status for this Ring Out port. By setting this parameter, a remote manager can control the partitioning of this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER isolate(1), enable(2)  

stackableHubRoPhDet 1.3.6.1.4.1.260.1.3.1.2.1.14
This parameter describes the phantom detect status for this Ring Out port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wireFault(1), phantOk(2)  

stackableHubRoNsrtStatus 1.3.6.1.4.1.260.1.3.1.2.1.15
Insertion status for this Ring Out port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bypassed(1), inserted(2)  

stackableHubRoBcnRemStatus 1.3.6.1.4.1.260.1.3.1.2.1.16
This parameter describes the result of any automatic beacon removal operations performed by the agent on this port. Automatic beacon removal operations consist of agent-initiated isolation of a lobe port in order to remove the cause of a persistent beaconing condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), autoIsolated(2)  

stackableHubRoNeighborType 1.3.6.1.4.1.260.1.3.1.2.1.17
This parameter indicates the type of nearest neighbor on the Ring Out port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER series828(1), fSeries(2), tokenRingMAC(3), none(4), stackable(5)  

stackableHubRoNeighborAddr 1.3.6.1.4.1.260.1.3.1.2.1.18
The address of the nearest neighbor on the Ring Out port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2..6)  

stackableHubRoTimeStamp 1.3.6.1.4.1.260.1.3.1.2.1.19
The time the status of Ring Out (was) last changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

stackableHubDataRateState 1.3.6.1.4.1.260.1.3.1.2.1.20
This parameter indicates the current data rate of this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s4Mbps(1), s16Mbps(2), autoConfig(3)  

stackableHubDataRateTimeStamp 1.3.6.1.4.1.260.1.3.1.2.1.21
The time the data rate status (was) last changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

stackableHubMgmtStatus 1.3.6.1.4.1.260.1.3.1.2.1.22
The operational status of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER operational(1), down(2)  

stackableHubProxyAgentID 1.3.6.1.4.1.260.1.3.1.2.1.23
The physical layer MAC Address of the agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6..6)  

stackableHubAttachedAgentType 1.3.6.1.4.1.260.1.3.1.2.1.24
The type of the attached agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER tokenring(1), tokenring-ethernet(2), reserved(3), none(4)  

stackableHubAttachedAgentState 1.3.6.1.4.1.260.1.3.1.2.1.25
The state of the attached agent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), not-applicable(3)  

stackableHubTemperatureStatus 1.3.6.1.4.1.260.1.3.1.2.1.26
The temperature status of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), bad(2)  

stackableHubAutoRecovControl 1.3.6.1.4.1.260.1.3.1.2.1.27
This parameter controls the auto recovery operation of this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), reset(3), unknown(4)  

stackableHubAutoRecovRetries 1.3.6.1.4.1.260.1.3.1.2.1.28
The number of Auto Recoveries performed by this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

stackableHubCodeVersion 1.3.6.1.4.1.260.1.3.1.2.1.29
The firmware version number of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2..2)  

stackableHubAutoRecovState 1.3.6.1.4.1.260.1.3.1.2.1.30
The auto recovery state of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER in-recovery(1), normal(2), halted(3)  

stackableHubRawCommandData 1.3.6.1.4.1.260.1.3.1.2.1.31
This is used to send raw 485 serial data to this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..255)  

stackableHubAutoRecovMode 1.3.6.1.4.1.260.1.3.1.2.1.32
This parameter describes the auto recovery mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER selfEnabling(1), non-selfEnabling(2)  

stackableHubLobeNumber 1.3.6.1.4.1.260.1.3.1.3
The number of items in the hub lobe table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

stackableHubLobeTable 1.3.6.1.4.1.260.1.3.1.4
A table which contains the control and status information for the lobes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StackablehubLobeEntry

stackableHubLobeEntry 1.3.6.1.4.1.260.1.3.1.4.1
A collection of control and status parameters kept for each lobe.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  StackablehubLobeEntry  

stackableHubIndex 1.3.6.1.4.1.260.1.3.1.4.1.1
The index into the stackableHubTable of the mau this lobe is on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

stackableHubLobePort 1.3.6.1.4.1.260.1.3.1.4.1.2
The port of the mau this lobe is on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

stackableHubLobePhDet 1.3.6.1.4.1.260.1.3.1.4.1.3
Phantom current status for this lobe port. A value of 1 corresponds to no phantom current detected. A value of 2 corresponds to phantom presence.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noPhantom(1), phantDetected(2)  

stackableHubLobeMask 1.3.6.1.4.1.260.1.3.1.4.1.4
Administrative status for this lobe port. By setting this parameter, a remote manager can control access to the lobe port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER isolated(1), enabled(2)  

stackableHubLobeNsrtStatus 1.3.6.1.4.1.260.1.3.1.4.1.5
Actual insertion status for this lobe port. A 1 value means that the corresponding station is not connected to the ring. A 2 value means that the corresponding station is connected to the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bypassed(1), inserted(2)  

stackableHubLobeMacAddr 1.3.6.1.4.1.260.1.3.1.4.1.6
The MAC layer address of the station which is attached to the corresponding lobe port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6..6)  

stackableHubLobeBcnRemStatus 1.3.6.1.4.1.260.1.3.1.4.1.7
This parameter describes the result of any automatic beacon removal operations performed by the agent on this port. Automatic beacon removal operations consist of agent-initiated isolation of a lobe port in order to remove the cause of a persistent beaconing condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), autoIsolated(2), unknown(3)  

stackableHubLobeBcnRemCause 1.3.6.1.4.1.260.1.3.1.4.1.8
This parameter describes the cause of any automatic beacon removal operations performed by the agent on this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no-removal(1), phantom-error(2), no-carrier(3), bad-rate(4), unknown(5)  

stackableHubLobeTimeStamp 1.3.6.1.4.1.260.1.3.1.4.1.9
The time the status of this lobe (was) last changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

superStackHubs 1.3.6.1.4.1.260.1.3.2
OBJECT IDENTIFIER    

superStackHubNumber 1.3.6.1.4.1.260.1.3.2.1
The number of items in hub table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

superStackHubTable 1.3.6.1.4.1.260.1.3.2.2
A table which maintains a list of all of the intelligent superStack series hubs on the ring being managed by the addressed agent. This table is indexed by the RS485 OOB address of the superStack series intelligent hubs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SuperStackHubTableEntry

superStackHubTableEntry 1.3.6.1.4.1.260.1.3.2.2.1
An entry in the superStackHubTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SuperStackHubTableEntry  

superStackHubTableIndex 1.3.6.1.4.1.260.1.3.2.2.1.1
The index for this hub entry
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

superStackHubModel 1.3.6.1.4.1.260.1.3.2.2.1.2
The model number of the superStack series hub being managed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active-12-port-base-mau(1), active-24-port-expansion-mau(2)  

superStackHub485Address 1.3.6.1.4.1.260.1.3.2.2.1.3
The 6 hex digit address used on the RS485 serial OOB management channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3..3)  

superStackHubStackPosition 1.3.6.1.4.1.260.1.3.2.2.1.4
The integer position in a stack of units. The top position is 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

superStackRiConfiguration 1.3.6.1.4.1.260.1.3.2.2.1.5
This parameter describes the physical configured state of Ring In. Ring In is disabled if there is another Ring In within the cascaded stack of hubs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no-ring-in-configured(1), copper-ring-in-configured(2), fiber-ring-in-configured(3), copper-ring-in-disabled(4), fiber-ring-in-disabled(5)  

superStackHubRiFTolState 1.3.6.1.4.1.260.1.3.2.2.1.6
This parameter controls the Ring In (RI) fault tolerance behavior. Off(1) means that phantom current is not used on the corresponding RI interface as a condition for main ring link insertion. On (2) means tha phantom current is used on the corresponding RI interface as a condition for main ring link insertion. The preferred setting for this parameter is on (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

superStackHubRiMask 1.3.6.1.4.1.260.1.3.2.2.1.7
Administrative status for this Ring In port. By setting this parameter, a remote manager can control the partitioning of this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER isolate(1), enable(2)  

superStackHubRiPhDet 1.3.6.1.4.1.260.1.3.2.2.1.8
This parameter describes the phantom detect status for this Ring In port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noPhantom(1), phantDetected(2)  

superStackHubRiNsrtStatus 1.3.6.1.4.1.260.1.3.2.2.1.9
Insertion status for this Ring In port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bypassed(1), inserted(2)  

superStackHubRiBcnRemStatus 1.3.6.1.4.1.260.1.3.2.2.1.10
This parameter describes the result of any automatic beacon removal operations performed by the agent on this port. Automatic beacon removal operations consist of agent-initiated isolation of a lobe port in order to remove the cause of a persistent beaconing condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), autoIsolated(2)  

superStackRoConfiguration 1.3.6.1.4.1.260.1.3.2.2.1.11
This parameter describes the physical configured state of Ring Out. Ring Out is disabled if there is another Ring Out within the cascaded stack of hubs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no-ring-out-configured(1), copper-ring-out-configured(2), fiber-ring-out-configured(3), copper-ring-out-disabled(4), fiber-ring-out-disabled(5)  

superStackHubRoFTolState 1.3.6.1.4.1.260.1.3.2.2.1.12
This parameter controls the Ring Out(RO) fault tolerance behavior. Off(1) means that phantom current is not used on the corresponding RO interface as a condition for main ring link insertion. On (2) means tha phantom current is used on the corresponding RO interface as a condition for main ring link insertion. The preferred setting for this parameter is on (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

superStackHubRoMask 1.3.6.1.4.1.260.1.3.2.2.1.13
Administrative status for this Ring Out port. By setting this parameter, a remote manager can control the partitioning of this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER isolate(1), enable(2)  

superStackHubRoPhDet 1.3.6.1.4.1.260.1.3.2.2.1.14
This parameter describes the phantom detect status for this Ring Out port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noPhantom(1), phantDetected(2)  

superStackHubRoNsrtStatus 1.3.6.1.4.1.260.1.3.2.2.1.15
Insertion status for this Ring Out port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bypassed(1), inserted(2)  

superStackHubRoBcnRemStatus 1.3.6.1.4.1.260.1.3.2.2.1.16
This parameter describes the result of any automatic beacon removal operations performed by the agent on this port. Automatic beacon removal operations consist of agent-initiated isolation of a lobe port in order to remove the cause of a persistent beaconing condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), autoIsolated(2)  

superStackHubCascadeUpMask 1.3.6.1.4.1.260.1.3.2.2.1.17
Administrative status for this Cascade Up connection. By setting this parameter, a remote manager can control the partitioning of this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER isolate(1), enable(2)  

superStackHubCascadeUpPhDet 1.3.6.1.4.1.260.1.3.2.2.1.18
This parameter describes the phantom detect status for this Cascade Up connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noPhantom(1), phantDetected(2)  

superStackHubCascadeUpNsrtStatus 1.3.6.1.4.1.260.1.3.2.2.1.19
Insertion status for this Cascade Up connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bypassed(1), inserted(2)  

superStackHubCascadeUpBcnRemStatus 1.3.6.1.4.1.260.1.3.2.2.1.20
This parameter describes the result of any automatic beacon removal operations performed by the agent on this connection. Automatic beacon removal operations consist of agent-initiated isolation of a lobe port in order to remove the cause of a persistent beaconing condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), autoIsolated(2)  

superStackHubCascadeDownMask 1.3.6.1.4.1.260.1.3.2.2.1.21
Administrative status for this Cascade Down connection. By setting this parameter, a remote manager can control the partitioning of this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER isolate(1), enable(2)  

superStackHubCascadeDownPhDet 1.3.6.1.4.1.260.1.3.2.2.1.22
This parameter describes the phantom detect status for this Cascade Down connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noPhantom(1), phantDetected(2)  

superStackHubCascadeDownNsrtStatus 1.3.6.1.4.1.260.1.3.2.2.1.23
Insertion status for this Cascade Down connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bypassed(1), inserted(2)  

superStackHubCascadeDownBcnRemStatus 1.3.6.1.4.1.260.1.3.2.2.1.24
This parameter describes the result of any automatic beacon removal operations performed by the agent on this connection. Automatic beacon removal operations consist of agent-initiated isolation of a lobe port in order to remove the cause of a persistent beaconing condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), autoIsolated(2)  

superStackHubDataRateState 1.3.6.1.4.1.260.1.3.2.2.1.25
This parameter indicates the current data rate of this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER s4Mbps(1), s16Mbps(2), autoConfig(3)  

superStackHubDeviceTimeStamp 1.3.6.1.4.1.260.1.3.2.2.1.26
The time the data rate status (was) last changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

superStackHubMgmtStatus 1.3.6.1.4.1.260.1.3.2.2.1.27
The operational status of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER operational(1), down(2)  

superStackHubProxyAgentID 1.3.6.1.4.1.260.1.3.2.2.1.28
The physical layer MAC Address of the agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6..6)  

superStackHubAttachedAgentType 1.3.6.1.4.1.260.1.3.2.2.1.29
The type of the attached agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), unknown(2), basic-68000(3), advanced-960(4), reserved1(5), reserved2(6), reserved3(7), reserved4(8), reserved5(9)  

superStackHubAttachedAgentState 1.3.6.1.4.1.260.1.3.2.2.1.30
The state of the attached agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER not-applicable(1), normal(2), duplicate-detected(3), management-disabled(4), hardware-faulted(5), agent-MAC-auto-isolated(6), agent-MAC-mgmt-isolated(7), reserved1(8), reserved2(9), reserved3(10), reserved4(11), reserved5(12)  

superStackHubAttachedAgentControl 1.3.6.1.4.1.260.1.3.2.2.1.31
This parameter allows control of the agent. Disabling the agent causes it to stop communicating (via the cascade) with other devices but it still allows for insertion of the MAC. The enable/isolate-MAC-insertion commands cause the agents MAC to be inserted or looped back respectively. this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), enable-MAC-insertion(3), isolate-MAC-insertion(4), read-value(5)  

superStackHubTemperatureStatus 1.3.6.1.4.1.260.1.3.2.2.1.32
The temperature status of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), bad(2)  

superStackHubPowerStatus 1.3.6.1.4.1.260.1.3.2.2.1.33
The power status of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normal-AC-power(1), normal-redundant-DC-power(2), non-redundant-DC-power(3)  

superStackHubAutoRecovControl 1.3.6.1.4.1.260.1.3.2.2.1.34
This parameter controls the auto recovery operation of this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), reset(3), unknown(4)  

superStackHubAutoRecovRetries 1.3.6.1.4.1.260.1.3.2.2.1.35
The number of Auto Recoveries performed by this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

superStackHubCodeVersion 1.3.6.1.4.1.260.1.3.2.2.1.36
The firmware version number of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2..2)  

superStackHubAutoRecovState 1.3.6.1.4.1.260.1.3.2.2.1.37
The current auto recovery state of this unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER in-recovery(1), normal(2), halted(3)  

superStackHubRawCommandData 1.3.6.1.4.1.260.1.3.2.2.1.38
This is used to send raw 485 serial data to this unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..255)  

superStackHubAutoRecovMode 1.3.6.1.4.1.260.1.3.2.2.1.39
This parameter describes the auto recovery mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER selfEnabling(1), non-selfEnabling(2)  

superStackHubRouterPortPhDet 1.3.6.1.4.1.260.1.3.2.2.1.40
Phantom current status for the router port on rear. A value of 1 corresponds to no phantom current detected. A value of 2 corresponds to phantom presence.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noPhantom(1), phantDetected(2)  

superStackHubRouterPortMask 1.3.6.1.4.1.260.1.3.2.2.1.41
Administrative status for the router port on rear. By setting this parameter, a remote manager can control access to the lobe port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER isolated(1), enabled(2)  

superStackHubRouterPortNsrtStatus 1.3.6.1.4.1.260.1.3.2.2.1.42
Actual insertion status for the router port on rear. A 1 value means that the corresponding station is not connected to the ring. A 2 value means that the corresponding station is connected to the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bypassed(1), inserted(2)  

superStackHubRouterPortMacAddr 1.3.6.1.4.1.260.1.3.2.2.1.43
The MAC layer address of the station which is attached to the router port on rear.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6..6)  

superStackHubRouterPortBcnRemStatus 1.3.6.1.4.1.260.1.3.2.2.1.44
This parameter describes the result of any automatic beacon removal operations performed by the agent on the router port. Automatic beacon removal operations consist of agent-initiated isolation of a lobe port in order to remove the cause of a persistent beaconing condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), autoIsolated(2), unknown(3)  

superStackHubRouterPortBcnRemCause 1.3.6.1.4.1.260.1.3.2.2.1.45
This parameter describes the cause of any automatic beacon removal operations performed by the agent on this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no-removal(1), phantom-error(2), no-carrier(3), bad-rate(4), unknown(5)  

superStackHubLobeNumber 1.3.6.1.4.1.260.1.3.2.3
The number of items in the hub lobe table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

superStackHubLobeTable 1.3.6.1.4.1.260.1.3.2.4
A table which contains the control and status information for the lobes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SuperStackHubLobeEntry

superStackHubLobeEntry 1.3.6.1.4.1.260.1.3.2.4.1
A collection of control and status parameters kept for each lobe.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SuperStackHubLobeEntry  

superStackHubIndex 1.3.6.1.4.1.260.1.3.2.4.1.1
The index into the superStackHubTable of the mau this lobe is on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

superStackHubLobePort 1.3.6.1.4.1.260.1.3.2.4.1.2
The port of the mau this lobe is on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

superStackHubLobeConfig 1.3.6.1.4.1.260.1.3.2.4.1.3
The hardware configuration of the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER user-normal(1), ring-out-unused(2), ring-in-unused(3), unknown(4)  

superStackHubLobePhDet 1.3.6.1.4.1.260.1.3.2.4.1.4
Phantom current status for this lobe port. A value of 1 corresponds to no phantom current detected. A value of 2 corresponds to phantom presence.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noPhantom(1), phantDetected(2)  

superStackHubLobeMask 1.3.6.1.4.1.260.1.3.2.4.1.5
Administrative status for this lobe port. By setting this parameter, a remote manager can control access to the lobe port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER isolated(1), enabled(2)  

superStackHubLobeNsrtStatus 1.3.6.1.4.1.260.1.3.2.4.1.6
Actual insertion status for this lobe port. A 1 value means that the corresponding station is not connected to the ring. A 2 value means that the corresponding station is connected to the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bypassed(1), inserted(2)  

superStackHubLobeMacAddr 1.3.6.1.4.1.260.1.3.2.4.1.7
The MAC layer address of the station which is attached to the corresponding lobe port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6..6)  

superStackHubLobeBcnRemStatus 1.3.6.1.4.1.260.1.3.2.4.1.8
This parameter describes the result of any automatic beacon removal operations performed by the agent on this port. Automatic beacon removal operations consist of agent-initiated isolation of a lobe port in order to remove the cause of a persistent beaconing condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), autoIsolated(2), unknown(3)  

superStackHubLobeBcnRemCause 1.3.6.1.4.1.260.1.3.2.4.1.9
This parameter describes the cause of any automatic beacon removal operations performed by the agent on this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no-removal(1), phantom-error(2), no-carrier(3), bad-rate(4), unknown(5)  

managers 1.3.6.1.4.1.260.2.1
OBJECT IDENTIFIER    

mgrNumber 1.3.6.1.4.1.260.2.1.1
The number of managers in the manager table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mgrAutoAdd 1.3.6.1.4.1.260.2.1.2
This variable indicates whether any manager that communicates with the agent should be added to the manager table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

mgrAutoAge 1.3.6.1.4.1.260.2.1.3
When mgrAutoAdd is enabled, this variable then indicates whether manager entries should be deleted after 'mgrAgeInterval' ticks. This variable has no effect when mgrAutoAdd is disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

mgrAgeInterval 1.3.6.1.4.1.260.2.1.4
This is the aging interval.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

mgrTable 1.3.6.1.4.1.260.2.1.5
A list of managers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MgrEntry

mgrEntry 1.3.6.1.4.1.260.2.1.5.1
A manager entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MgrEntry  

mgrIndex 1.3.6.1.4.1.260.2.1.5.1.1
The Index number of the Manager Entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mgrIpAddr 1.3.6.1.4.1.260.2.1.5.1.2
The IP address of the manager.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

mgrCommunity 1.3.6.1.4.1.260.2.1.5.1.3
The Community of the manager.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

mgrTimeStamp 1.3.6.1.4.1.260.2.1.5.1.4
Time of last communication with the manager.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

mgrStatus 1.3.6.1.4.1.260.2.1.5.1.5
The Status of this Entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

mgrPhysAddr 1.3.6.1.4.1.260.2.1.5.1.6
The physical address of the manager entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6..6)  

mgrInterfaceIndex 1.3.6.1.4.1.260.2.1.5.1.7
The Interface Index of the manager entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

versions 1.3.6.1.4.1.260.2.2
OBJECT IDENTIFIER    

configuration 1.3.6.1.4.1.260.2.3
OBJECT IDENTIFIER    

versionHardware 1.3.6.1.4.1.260.2.2.1
The Version of hardware release.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2..2)  

versionEPROMFirmware 1.3.6.1.4.1.260.2.2.2
The Version of EPROM release.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2..2)  

versionFLASHFirmware 1.3.6.1.4.1.260.2.2.3
The Version of FLASH release.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2..2)  

configEPROMSize 1.3.6.1.4.1.260.2.3.1
The Quantity of EPROM installed (number of bytes).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

configFLASHSize 1.3.6.1.4.1.260.2.3.2
The Quantity of FLASH installed (number of bytes).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

configFLASHCount 1.3.6.1.4.1.260.2.3.3
The Quantity of FLASH installed (number of ICs).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

configDRAMSize 1.3.6.1.4.1.260.2.3.4
The Quantity of DRAM installed (number of bytes).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

configDRAMCount 1.3.6.1.4.1.260.2.3.5
The Quantity of DRAM installed (number of SIMMs).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

configRS232Number 1.3.6.1.4.1.260.2.3.6
The Number of RS-232 ports in the RS-232 port table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

configRS232PortTable 1.3.6.1.4.1.260.2.3.7
A list of port entries. The number of entries is given by the value of configRS232Number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConfigRS232PortEntry

configRS232PortEntry 1.3.6.1.4.1.260.2.3.7.1
Status and parameter values for a port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConfigRS232PortEntry  

configRS232PortIndex 1.3.6.1.4.1.260.2.3.7.1.1
A unique value for each port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

configRS232PortName 1.3.6.1.4.1.260.2.3.7.1.2
A text description of the port, i.e. COM1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

configRS232BaudRate 1.3.6.1.4.1.260.2.3.7.1.3
The baudrate at which the port is operating.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER b1200(1), b2400(2), b4800(3), b9600(4), b19200(5), b38400(6)  

configRS232ModemStatus 1.3.6.1.4.1.260.2.3.7.1.4
The current status of the modem port connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER modemDetected(1), autobauding(2), noModemDetected(3)  

configRS232ConnectionStatus 1.3.6.1.4.1.260.2.3.7.1.5
The current status of the modem data connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER connected(1), connectionWait(2), unknown(3)  

configRS232ModemConfigString 1.3.6.1.4.1.260.2.3.7.1.6
A user-configurable ASCII string used to initialize a modem on this port. If this string is set to Z, the Star-Tek Agent sends ATZ to the modem during configuration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..40)  

configRS232OutputData 1.3.6.1.4.1.260.2.3.7.1.7
Raw data to be sent out this port. Data can only be sent if the ConnectionStatus is connectionWait.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..42)  

configRS232InputData 1.3.6.1.4.1.260.2.3.7.1.8
The response, if any, to the output data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..100)  

configRS232HardwareFlowControl 1.3.6.1.4.1.260.2.3.7.1.9
Controls the use of RTS-CTS hardware flow control during modem connections.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

configMonitorMode 1.3.6.1.4.1.260.2.3.8
The mode of operation of the monitor port. The monitor port is COM2 (if present, COM1 if not).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER monitor(1), slip(2)  

configMonitorInput 1.3.6.1.4.1.260.2.3.9
Controls whether the monitor function will accept input.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

configMonitorDiags 1.3.6.1.4.1.260.2.3.10
Controls whether the monitor function will produce diagnostic output.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

configParseControl 1.3.6.1.4.1.260.2.3.11
Controls the degree to which frames are copied and parsed. Under high network loads this control can be used to prevent agent overload.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER parseAll(1), parseMost(2), parseLess(3), parseNone(4)  

configBootSource 1.3.6.1.4.1.260.2.3.12
Describes where the agent is executing code from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER eprom(1), flash(2)  

security 1.3.6.1.4.1.260.2.4
OBJECT IDENTIFIER    

securityControl 1.3.6.1.4.1.260.2.4.1
This controls whether security is enabled or disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

securityMacAddressTable 1.3.6.1.4.1.260.2.4.2
A table which maintains a list of MacAddresses which are from the local ring, along with a control field which specifies whether it is allowed or disallowed access to the local ring and a counter which tracks the number of times that address has been disallowed access to the ring.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SecurityMacAddressTableEntry

securityMacAddressTableEntry 1.3.6.1.4.1.260.2.4.2.1
An entry in the securityMacAddressTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SecurityMacAddressTableEntry  

securityMacAddress 1.3.6.1.4.1.260.2.4.2.1.1
The Token Ring Mac Address for this entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6..6)  

securityStatus 1.3.6.1.4.1.260.2.4.2.1.2
Specifies whether this address is allowed or disallowed to be on the local ring.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER allowed(1), disallowed(2)  

securityLockoutCount 1.3.6.1.4.1.260.2.4.2.1.3
The number of times this address was disallowed on the local ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

recovery 1.3.6.1.4.1.260.2.5
OBJECT IDENTIFIER    

recoveryControl 1.3.6.1.4.1.260.2.5.1
This variable controls whether or not this agent will Accelerate the token-ring recovery process. Enabled by default.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

recovery828Support 1.3.6.1.4.1.260.2.5.2
This variable controls whether this agent will perform Accelerated Recovery on model 828 devices. Disabled by default.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

recoveryRetryLimit 1.3.6.1.4.1.260.2.5.3
This variable controls the maximum number of Accelerated Recovery events that will be attempted within recoveryRetryTimePeriod seconds of each other.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

recoveryRetryTimePeriod 1.3.6.1.4.1.260.2.5.4
The number of seconds which must elapse between Recovery events in order for them to be considered non-related and non-limited.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rmonextns 1.3.6.1.4.1.260.4
OBJECT IDENTIFIER    

stationstatistics 1.3.6.1.4.1.260.4.1
OBJECT IDENTIFIER    

stationhistory 1.3.6.1.4.1.260.4.2
OBJECT IDENTIFIER    

trHistoryTable 1.3.6.1.4.1.260.4.2.1
A list of Token Ring history entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TrHistoryEntry

trHistoryEntry 1.3.6.1.4.1.260.4.2.1.1
An historical sample of Token Ring statistics on a particular Token Ring interface (on a per station basis). This sample is associated with the historyControlEntry which set up the parameters for a regular collection of these samples.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TrHistoryEntry  

trHistoryIndex 1.3.6.1.4.1.260.4.2.1.1.1
The history of which this entry is a part. The history identified by a particular value of this index is the same history as identified by the same value of historyControlIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

trHistorySampleIndex 1.3.6.1.4.1.260.4.2.1.1.2
An index that uniquely identifies the particular sample this entry represents among all samples associated with the same historyControlEntry. This index starts at 1 and increases by one as each new sample is taken.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trHistoryIntervalStart 1.3.6.1.4.1.260.4.2.1.1.3
The value of sysUpTime at the start of the interval over which this sample was measured. If the probe keeps track of the time of day, it should start the first sample of the history at a time such that when the next hour of the day begins, a sample is started at that instant. Note that following this rule may require the probe to delay collecting the first sample of the history, as each sample must be of the same interval. Also note that the sample which is currently being collected is not accessible in this table until the end of its interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

trHistoryInPkts 1.3.6.1.4.1.260.4.2.1.1.4
The number of packets (including error packets) received by this station, during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryOutPkts 1.3.6.1.4.1.260.4.2.1.1.5
The number of packets (including error packets) transmitted by this station, during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryInOctets 1.3.6.1.4.1.260.4.2.1.1.6
The total number of octets of data (including those in bad packets) received on the network (excluding framing bits but including FCS octets) by this station, during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryOutOctets 1.3.6.1.4.1.260.4.2.1.1.7
The total number of octets of data (including those in bad packets) transmitted on the network (excluding framing bits but including FCS octets) by this station, during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryOutBroadcastPkts 1.3.6.1.4.1.260.4.2.1.1.8
The total number of good packets transmitted on the network that were directed to the broadcast address by this station, during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryOutMulticastPkts 1.3.6.1.4.1.260.4.2.1.1.9
The total number of good packets transmitted on the network that were directed to a multicast address by this station, during this sampling interval. Note that this number does not include packets addressed to the broadcast address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryClaimTokenPkts 1.3.6.1.4.1.260.4.2.1.1.10
The total number of Claim Token MAC packets detected by this station during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryInLineErrors 1.3.6.1.4.1.260.4.2.1.1.11
The total number of line errors reported by this station in error reporting packets detected by the probe during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryOutLineErrors 1.3.6.1.4.1.260.4.2.1.1.12
The total number of line errors reported in error reporting packets sent by the nearest active downstream neighbor of this station and detected by the probe during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryInternalErrors 1.3.6.1.4.1.260.4.2.1.1.13
The total number of adapter internal errors reported by this station in error reporting packets detected by the probe during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryInBurstErrors 1.3.6.1.4.1.260.4.2.1.1.14
The total number of burst errors reported by this station in error reporting packets detected by the probe during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryOutBurstErrors 1.3.6.1.4.1.260.4.2.1.1.15
The total number of burst errors reported in error reporting packets sent by the nearest active downstream neighbor of this station and detected by the probe, during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryACErrors 1.3.6.1.4.1.260.4.2.1.1.16
The total number of AC (Address Copied) errors reported in error reporting packets sent by the nearest active downstream neighbor of this station and detected by the probe during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryAbortErrors 1.3.6.1.4.1.260.4.2.1.1.17
The total number of abort delimiters reported by this station in error reporting packets detected by the probe during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryLostFrameErrors 1.3.6.1.4.1.260.4.2.1.1.18
The total number of lost frame errors reported by this station in error reporting packets detected by the probe during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryCongestionErrors 1.3.6.1.4.1.260.4.2.1.1.19
The total number of receive congestion errors reported by this station in error reporting packets detected by the probe during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryFrameCopiedErrors 1.3.6.1.4.1.260.4.2.1.1.20
The total number of frame copied errors reported by this station in error reporting packets detected by the probe during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryFrequencyErrors 1.3.6.1.4.1.260.4.2.1.1.21
The total number of frequency errors reported by this station in error reporting packets detected by the probe during this sampling interval.
Status: optional Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryTokenErrors 1.3.6.1.4.1.260.4.2.1.1.22
The total number of token errors reported by this station in error reporting packets detected by the probe during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryInBeaconErrors 1.3.6.1.4.1.260.4.2.1.1.23
The total number of beacon frames sent by this station and detected by the probe, during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryOutBeaconErrors 1.3.6.1.4.1.260.4.2.1.1.24
The total number of beacon frames detected by the probe, that name this station as the NAUN, during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryInsertions 1.3.6.1.4.1.260.4.2.1.1.25
The number of times the probe detected this station inserting onto the ring during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistorySoftErrors 1.3.6.1.4.1.260.4.2.1.1.26
The number of soft errors reported by this station in error reporting packets detected by the probe during this sampling interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trHistoryOpaqueTable 1.3.6.1.4.1.260.4.2.2
A list of Token Ring history entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TrHistoryOpaqueEntry

trHistoryOpaqueEntry 1.3.6.1.4.1.260.4.2.2.1
An historical sample of Token Ring statistics on a particular Token Ring interface. This sample is associated with the historyControlEntry which set up the parameters for a regular collection of these samples.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TrHistoryOpaqueEntry  

trHistoryTableData 1.3.6.1.4.1.260.4.2.2.1.1
An opaque data structure used for management.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Opaque  

protocolstatistics 1.3.6.1.4.1.260.4.3
OBJECT IDENTIFIER    

protocolData 1.3.6.1.4.1.260.4.3.1
An opaque data structure used for data retrival.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Opaque  

protocolStatsTable 1.3.6.1.4.1.260.4.3.2
A list of protocol statistics entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ProtocolStatsEntry

protocolStatsEntry 1.3.6.1.4.1.260.4.3.2.1
An entry in the protocolStatsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ProtocolStatsEntry  

protocolIfIndex 1.3.6.1.4.1.260.4.3.2.1.1
The value of this object uniquely identifies the interface on this remote network monitoring device on which this station was detected. The interface identified by a particular value of this object is the same interface as identified by the same value of the ifindex object, defined in [4,6].
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

protocolID 1.3.6.1.4.1.260.4.3.2.1.2
The value of this object uniquely identifies the protocol whose counters are tracked by this table entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER all-packets(1), unknown-protocols(2), ieee8025-mac-protocol(3), ieee8025-source-routed-packets(4), ieee8025-nonsource-routed-packets(5), dix-ethernet-packets(6), ieee8022-llc-protocol(7), ieee8022-llc-snap(8), ip(9), ip-icmp(10), ip-gcp(11), ip-tcp(12), ip-egp(13), ip-igp(14), ip-chaos(15), ip-udp(16), ip-tp4(17), ip-other(18), arp(19), netware-ipx(20), llc-null-sap(21), llc-individual-mgmt-sap(22), llc-group-mgmt-sap(23), llc-individual-sna-path-ctrl-sap(24), llc-group-sna-path-ctrl-sap(25), llc-arpanet-ip-sap(26), llc-3com-xns-sap(27), llc-netbios-sap(28), llc-individual-lan-mgmt-sap(29), llc-group-lan-mgmt-sap(30), llc-remote-program-load-sap(31), llc-iso-network-layer-sap(32), llc-global-sap(33), other-llc-sap(34), chaosnet(35), banyan-vines(36), decnet(37), dec-lat(38), dec-lanbridge(39), appletalk(40), xerox-3com(41), ipx-uknown(42), ipx-routinginformationpacket(43), ipx-echopacket(44), ipx-errorpacket(45), ipx-packetexchangeprotocol(46), ipx-sequencedpacketprotocol(47), ipx-netwarecoreprotocol(48), ipx-other(49), ncp(50), ncp-create(51), ncp-request(52), ncp-reply(53), ncp-destroyserviceconnection(54), ncp-requestinprogressresponse(55), ncp-other(56), sap-generalservicequery(57), sap-generalserviceresponse(58), sap-nearestserverquery(59), sap-nearestserverresponse(60), llc-startekdiscovery(61), reserved62(62), reserved63(63), reserved64(64), reserved65(65), reserved66(66), reserved67(67), reserved68(68), reserved69(69), reserved70(70), reserved71(71), reserved72(72), reserved73(73), reserved74(74), reserved75(75), reserved76(76), reserved77(77), reserved78(78), reserved79(79), reserved80(80), reserved81(81), reserved82(82)  

protocolPkts 1.3.6.1.4.1.260.4.3.2.1.3
The number of packets received for this protocol.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

protocolOctets 1.3.6.1.4.1.260.4.3.2.1.4
The number of octets received for this protocol.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter